• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Utveckling och tillverkning av flödestestkammare med högupplöst motstånd för kompaktfläktar : Mätinstrument som mäter statiskt tryck och luftflöde för framställning av fläktkurvor vid prestandamätning av kompaktfläktar / Design and verification of an airflow test chamber for compact fans using a high-resolution load : Instrument measuring static pressure and airflow for creation of fan curves during performance measurements of compact fans

Wallace, William, Wiström, Oskar January 2021 (has links)
Examensarbetet har utförts hos RotoSub AB i Linköping. RotoSub fokuserar på innovativa lösningar inom brusreducering för fläktar och är även utvecklingspartner med det österrikiska företaget Noctua, som utvecklar och tillverkar kompaktfläktar och processorkylare inom elektronikbranschen. Under examensarbetet har en flödestestkammare för kompaktfläktar utvecklats och tillverkats. Testkammaren utnyttjar ett högupplöst motstånd som ger möjlighet till ett flertal driftpunkter för att konstruera detaljerade fläktkurvor. Detta låter RotoSub noggrant analysera och undersöka fläktkaraktäristiken under utvecklingsstadiet. I rapporten undersöks två metoder för att bestämma luftflödet genom testkammaren. Däribland en känd geometri i form av munstycken, enligt den amerikanska standarden ANSI/AMCA 210-16 samt utnyttjandet av en varmtrådsanemometer. Vidare undersöks alternativ för att konstruera ett högupplöst motstånd med hög pålitlighet och repeterbarhet, samt en tryckmätningsmetod som tillåter en jämn avläsning av det statiskatrycket som testfläkten ger upphov till. Under utvecklingen tillverkades prototyper där koncept testades och utvärderades, innan slutprodukten kunde modelleras i ett CAD-program för att slutligen tillverkas fysiskt. Slutprodukten tillverkades huvudsakligen i styren-akrylnitril (SAN) samt ett fåtal komponenter i polylaktid (PLA) och aluminium. Testkammaren använder sig av en tryckring med fyra tryckportar, en varmtrådsanemometer för att mäta luftflödet samt en roterande skiva som drivs av en stegmotor för att högupplöst variera motståndet i testkammaren. Testkammaren har visat sig kapabel att konstruera fläktkurvor för samtliga fläktstorlekar undersökta under arbetet med god repeterbarhet. Vidare arbete finns gällande tätning, då ett visst läckage finns i testkammaren vilket ger ett systematiskt fel i fläktkurvorna vid låga flöden där maximalt statiskt tryck inte kan uppnås. / This undergraduate thesis has been carried out at RotoSub AB in Linköping, Sweden. RotoSub develop innovative solutions for noise-reduction in fans. RotoSub are also development partners to the Austrian company Noctua, who design and develop fans and processor coolers for the electronics industry. During the thesis a compact airflow test chamber has been designed and constructed. The test chamber utilises a high-resolution load to measure and create a fan curve. The high-resolution load ensures that a large amount of operating points can be measured, which gives RotoSub the opportunity to closely analyse the characteristics of the fan being tested. In this thesis two different methods of measuring the airflow through the test chamber have been studied. Firstly a method of using nozzles to calculate the flow according to the standard ANSI/AMCA 210-16. Secondly the use of hot-wire anemometry to measure the airflow through the test chamber. Methods of measuring static pressure behind the test fan with high accuracy and stable readings have also been studied. Different high-resolution loads have been studied to ensure high repeatability and reliability. During the development phase, prototypes of the different components were created to allow for testing and evaluation before a final design was chosen. After the designs for each component was decided, the final design was modelled in CAD before being fabricated and constructed. The construction mostly utilises styrene-acrylonitrile (SAN) but with certain components made from polylactic acid (PLA) and aluminium. Pressure readings are taken behind the fan being tested using static ports placed on the outside of a hollow diffuser, mounted on the inlet of the test chamber. The hollow diffuser is filled with foam to stabilise the pressure readings. The chosen method of measuring airflow through the test chamber was hot-wire anemometry for its broad measurement range, high accuracy and simplicity in implementation. The design of the high-resolution load was chosen to be a rotating gate with two ports. As the gate rotates these ports openor close. The rotating gate is driven by a stepper-motor. This design allowed for very fine control at high loads and ensures reliable operation with a minimal amount of moving parts. Tests with the finished test chamber have shown that the test chamber is capable of measuring and creating high-resolution fan curves with high repeatability. However the test chamber cannot measure static pressure at zero flow as there are currently leaks within the test chamber that allows a small amount of flow through the chamber when the variable load is fully closed. This leads to a systematic error when creatingfan curves, mainly at lower flow rates and higher static pressures. Further work with this test chamber is needed to reduce leaks, which would improve measurement precision.
2

Acceleratorers inverkan på betong avseende bearbetbarhet, pumpbarhet och hållfasthetstillväxt / Accelerators effect on concrete regarding processability, pumpability and strength development

Valden, Roger, Nehemiah, Temesgen January 2020 (has links)
The following thesis is a comparison study which was performed in cooperation with Sika Sverige AB. The project was to examine concrete’s behaviour while being subjected to different accelerators which is used to speed up the hardening process in young concrete. Sika provided the materials and the instructions for the tests that were made. The tests used where almost like the tests being performed at Sika’s laboratories but with some adjustments to the testing equipment. According to the results of the tests a clear difference between the different accelerators were found. The conclusion that the efficiency of the different accelerators were affected on several variables such as cement type, hardening age and hardening temperature were drawn. Because of the corona outbreak (2020) the tests could not be performed in Sikas laboratories. The tests were therefore carried out at a temporary laboratory without any direct supervision and some professional equipment could not be obtained which resulted in replacements with creative solutions. These changes affected the individual test results with high certainty but should not interfere with the conclusions on account that all test samples were subjected to the same circumstances.

Page generated in 0.0666 seconds