11 |
Diagnostic Value of Noninvasive Computed Tomography Perfusion Imaging and Coronary Computed Tomography Angiography for Assessing Hemodynamically Significant Native Coronary Artery LesionsSethi, Pooja, Panchal, Hemang B., Veeranki, Sreenivas P., Ur Rahman, Zia, Mamudu, Hadii, Paul, Timir K. 01 September 2017 (has links)
The objective of this study is to determine the diagnostic performance of computed tomography perfusion (CTP) with and without computed tomography angiography (CTA) in assessment of hemodynamically significant coronary artery lesions in comparison to invasive fractional flow reserve (FFR). Materials and Methods PubMed and Cochrane Center Register of Controlled Trials from January 2010 searched through December 2014. Nine original studies were selected evaluating the diagnostic performance of CTP with and without CTA to invasive coronary angiography in evaluation of hemodynamic significance of coronary lesions (n = 951). Results The sensitivity, specificity, LR+ and LR- and DOR of CTA+CTP were 0.85 [95% confidence interval (CI: 0.79-0.89)] 0.94 (CI: 0.91-0.97), 15.8 (CI: 7.99-31.39), 0.146 (CI: 0.08-0.26), and 147.2 (CI: 69.77-310.66). Summary Receiver Operating Characteristics (SROC) results showed area under the curve (AUC) of 0.97 indicating that CTA+CTP may detect hemodynamically significant coronary artery lesions with high accuracy. The sensitivity, specificity, LR+ and LR- and DOR of CTP were 0.83 (CI: 0.78-0.87), 0.84 (CI: 0.80-0.87) 5.26 (CI: 2.93-9.43), 0.209 (CI: 0.12-0.36), and 31.97 (CI: 11.59-88.20). Conclusions This result suggests that CTP with CTA significantly improves diagnostic performance of coronary artery lesions compared to CTA alone and closely comparable with invasive FFR.
|
12 |
The Clinical Significance of Physiological Assessment of Residual Ischemia After Percutaneous Coronary InterventionOjha, Chandra P., Ibrahim, Ahmed, Paul, Timir K., Mulukutla, Venkatachalam, Nagarajarao, Harsha S. 01 April 2020 (has links)
Purpose of Review: Fractional flow reserve (FFR) and instantaneous wave-free ratio (iFR) have emerged as the invasive diagnostic tools of choice for hemodynamic assessment of the severity of CAD (coronary artery disease). We sought to comprehensively review the evidence on the utility of hemodynamic assessment of the coronary stenoses after percutaneous coronary intervention (PCI) using FFR/iFR, mechanisms of positive post-PCI iFR/FFR, and the clinical impact of significant residual ischemia. Recent Findings: The evidence on the utility of the post-PCI hemodynamic assessment has accumulated over the last few years. The post hoc analysis from the FAME 1 and FAME 2 data shows that higher post-PCI FFR is associated with better symptomatic improvement and lower event rate with larger increase in delta FFR (∆ FFR: post-PCI FFR – pre-PCI FFR). Unlike pre-PCI FFR, a consensus has not been established on the optimal value of post-PCI FFR, though multiple studies point toward better clinical outcomes with higher post-PCI FFR and larger ∆ FFR. Summary: Visual assessment of adequate stent apposition by coronary angiography is insufficient in evaluating for residual ischemia. The hemodynamic evaluation of residual ischemia by post-PCI FFR/iFR yields clinically relevant data and allows for appropriate post PCI optimization.
|
13 |
Valor prognóstico da reserva de fluxo coronário e miocárdico obtida pela ecocardiografia contrastada em pacientes com cardiomiopatia dilatada de origem não isquêmica / Prognostic value of coronary and myocardial flow reserve obtained by contrast echocardiography in patients with nonischemic dilated cardiomyopathyLima, Marta Fernandes 14 May 2012 (has links)
Apesar dos avanços no entendimento da fisiopatologia e dos recursos terapêuticos atualmente disponíveis, a cardiomiopatia dilatada (CMD) permanece como uma condição com alta mortalidade, sendo que a disfunção microvascular é um dos mecanismos relacionados à piora da função cardíaca. Nos últimos anos, novas técnicas de ecocardiografia vêm sendo utilizadas para avaliação da disfunção microvascular, incluindo a medida de velocidade de fluxo coronário pelo Doppler da artéria coronária descendente anterior (ADA), e a análise quantitativa do fluxo miocárdico pela ecocardiografia com perfusão miocárdica em tempo-real (EPMTR). No presente estudo, avaliamos o valor prognóstico da reserva de velocidade de fluxo coronário (RVFC), obtida pelo Doppler da ADA, e da reserva de fluxo miocárdico (RFM), obtida pela EPMTR, para predizer morte e transplante cardíaco em pacientes com CMD de origem não isquêmica. Adicionalmente, avaliamos se as medidas de reserva de fluxo acrescentam valor prognóstico sobre variáveis clínicas e ecocardiográficas que já são conhecidas como preditores de eventos nesta população. Estudamos 195 pacientes com CMD (130 homens, média etária 54 ± 12 anos) que apresentavam fração de ejeção do ventrículo esquerdo inferior a 35% pelo ecocardiograma e ausência de sinais de doença arterial coronária obstrutiva por angiografia coronária invasiva ou por método não invasivo (cintilografia de perfusão miocárdica ou angiotomografia de coronárias). Foram analisados parâmetros ecocardiográficos convencionais de função sistólica e diastólica do ventrículo esquerdo em repouso. A velocidade de fluxo coronário foi determinada pelo Doppler pulsado na ADA e a dinâmica das microbolhas no miocárdio foi quantificada pela EPMTR utilizando programas computacionais específicos, tanto em repouso como durante o estresse pelo dipiridamol (0,84 mg/Kg). As RVFC, RFM e reserva de velocidade de repreenchimento de microbolhas no miocárdio (reserva ) foram obtidas pela relação entre os parâmetros de fluxo durante a hiperemia e em repouso, sendo consideradas diminuídas quando os valores estavam abaixo de 2,0. O tempo médio de acompanhamento foi de 29 meses (variando de 6 a 69 meses). Neste período, 45 pacientes (24%) apresentaram eventos, sendo 43 mortes de causa cardíaca e 2 transplantes cardíacos. Na análise univariada foram preditores de eventos: etiologia chagásica, classe funcional de insuficiência cardíaca, uso de inibidores da enzima conversora de angiotensina e/ou bloqueadores dos receptores de angiotensina II (fator protetor), diâmetros ventriculares e do átrio esquerdo, volumes ventriculares, fração de ejeção, disfunção diastólica, grau de insuficiência mitral, RVFC, RFM e reserva . Na análise multivariada, foram preditores independentes de eventos o diâmetro do átrio esquerdo (razão de chances = 1,16 por unidade de aumento; intervalo de confiança 95% = 1,078 1,264; p<0,001) e a reserva diminuída (razão de chances = 3,219; intervalo de confiança 95% = 1,178 8,795; p<0,001). No modelo sequencial de predição de eventos, fração de ejeção e diâmetro do átrio esquerdo adicionaram valor prognóstico às variáveis clínicas (aumento do qui-quadrado de 15,2 para 58,5; p < 0,001). A reserva adicionou poder ao modelo (qui-quadrado de 70,2; p<0,001). Concluímos que tanto a RVFC, obtida pelo Doppler da ADA, como a RFM e reserva , obtidas pela EPMTR sob estresse pelo dipiridamol, são preditoras de morte e transplante cardíaco em pacientes com CMD não isquêmica. Entretanto, somente o diâmetro do átrio esquerdo e a reserva mostraram valor prognóstico independente e incremental sobre variáveis clínicas e ecocardiográficas que já são conhecidas como preditores de eventos nesta população / Despite advances in understanding of the pathophysiology and therapeutic approaches, dilated cardiomyopathy (DCM) remains as a condition with high mortality and one of the mechanisms involved in this process seems to be microvascular dysfunction. Recently, new echocardiographic techniques have been incorporated in the clinical practice and used for the assessment of microvascular dysfunction, including evaluation of left anterior descending coronary artery (LAD) by Doppler and quantitative analysis of myocardial flow by real-time myocardial perfusion echocardiography (RTMPE). In the present study, we evaluated the prognostic value of coronary flow velocity reserve (CFVR), obtained by transthoracic echocardiography, and parameters of myocardial flow reserve (MFR), obtained by RTMPE for predicting cardiac death and heart transplantation in patients with nonischemic DCM. In addition, we sought to detect the incremental value of flow reserve over clinical and echocardiographic parameters already known as predictors of events in this population. We studied 195 patients with DCM (130 men, mean age 54 ± 12 years) who had left ventricular ejection fraction (LVEF) less than 35% by echocardiography and no signs of obstructive coronary artery disease by invasive coronary angiography or noninvasive methods (nuclear medicine or angiography by computed tomography). We assessed conventional echocardiographic parameters of systolic and diastolic left ventricular function at rest. Coronary flow velocity was determined by pulsed Doppler in LAD and dynamics of microbubbles in the myocardium was measured by RTMPE using specific computer programs, both at rest and during dipyridamole stress (0.84 mg/kg). CFVR, MFR and the reserve of velocity of microbubbles in the myocardium ( reserve) were obtained as the ratio between parameters of flow during hyperemia and at rest, being considered abnormal when these were below 2.0. The mean follow-up was 29 months (ranging from 6 to 69 months). During this period, 45 patients (24%) had events, 43 cardiac deaths and 2 heart transplantations. In the univariate analysis, predictors of events were: Chagas disease, New York Heart Association functional class, use of angiotensin-converting enzyme inhibitors/angiotensin II receptor blocker (protective effect), left ventricular and atrial diameters, left ventricular volumes, LVEF, diastolic dysfunction, degree of mitral regurgitation, CVFR, MFR and reserve. By multivariate analysis, the only independent predictors of events were the left atrial diameter (OR = 1.16, 95% confidence interval = 1.078 to 1.264, p <0.001) and reserve 2.0 (OR = 3.219, confidence interval 95 % = 1.178 to 8.795, p <0.001). In the sequential model of events prediction, LVEF and left atrial diameter added prognostic value over clinical factors (chi-square from 15.2 to 58.5; p<0.001). reserve added power to the model (chi-square = 70.2, p<0.001). We concluded that CVFR, obtained by Doppler in LAD, MFR and reserve, obtained by dipyridamole stress RTMPE, are predictors of cardiac death and heart transplantation in patients with nonischemic DCM. However, only left atrial diameter and depressed reserve showed independent and incremental predictive value beyond that provided by current known prognostic clinical and echocardiographic factors
|
14 |
Estudo comparativo do fluxo da artéria torácica interna utilizada \"in situ\" na revascularização miocárdica, com e sem a ligadura dos ramos proximais, utilizando a ecocardiografia Doppler / Comparative study of the internal thoracic artery flow used \"in situ\" for myocardial revascularization, with and without ligation of its proximal branches using Doppler echocardiographyAbreu, José Sebastião de 19 May 2015 (has links)
Fundamento: A artéria torácica interna (ATI) \"in situ\" apresenta predomínio de fluxo sistólico, mas após sua anastomose no sistema coronariano esquerdo torna-se um sistema híbrido com predomínio de fluxo diastólico, sendo a relevância da patência ou não dos grandes ramos proximais da ATI anastomosada controversa quanto à possibilidade de roubo de fluxo. Porém, constata-se que durante o ecocardiograma sob estresse com dobutamina (EED), o estado funcional da ATI anastomosada pode ser avaliado através da reserva coronariana, além da verificação dos distintos efeitos no fluxo sistólico (FS), diastólico (FD) e total (FT = sistólico + diastólico). Objetivo: Verificar por meio da ecocardiografia e Doppler o efeito dos ramos proximais importantes da ATI no fluxo, na reserva de velocidade (RVFC) e de fluxo (RFC) coronariano, em pacientes com fração de ejeção do ventrículo esquerdo (FEVE) preservada (> 50%). Métodos: Em ensaio clínico prospectivo controlado e randomizado, foram avaliados pacientes com (Grupo I) e sem (Grupo II), a ligadura dos ramos proximais importantes da ATI anastomosada na coronária descendente anterior. As avaliações das ATIs em nível supraclavicular e os ecocardiogramas transtorácicos foram realizados no pré-operatório, no pós-operatório precoce, seis meses após a cirurgia em condição basal e durante o EED. Neste, foi alcançada a frequência cardíaca submáxima [(220 - idade) x (0,85)] sem a ocorrência de isquemia no território subjacente à ATI anastomosada em todos os pacientes. Foram medidos o FS, o FD, o FT e o percentual de FD, nos quatro momentos do estudo. O percentual de FD resultou da divisão da integral da velocidade diastólica do fluxo pela integral da velocidade total (sistólica + diastólica) do fluxo. A reserva coronariana foi obtida através do Doppler da ATI anastomosada seis meses após a cirurgia, sendo calculada através da razão entre o valor da variável registrado no EED e em condição basal, utilizando-se para as RVFCs o pico e a média de velocidade diastólica, e para a RFC o FT. As distribuições das variáveis contínuas foram comparadas através do Teste t Student, quando as variáveis eram aproximadamente normais, ou através do Teste da Soma dos Postos de Wilcoxon (Mann-Whitney), quando as variáveis não eram aproximadamente normais. Proporções foram comparadas através do teste exato de Fisher. O valor-p < 0,05 entre os grupos foi considerado estatisticamente significativo. Resultados: O Grupo I (25 pacientes) e o Grupo II (28 pacientes) não foram diferentes quanto às características clínicas e ecocardiográficas, constatando-se a FEVE preservada em todos os casos. O FD não diferiu entre os grupos nos quatro momentos do estudo. Entretanto, verificou-se durante o EED que o FS (19,5 ± 9,3 ml/min vs. 32,7 ± 19,4 ml/min; p < 0,05) e o FT (79,1 ± 21,4 ml/min vs. 101,1 ± 47,4 ml/min; p < 0,05) foram maiores no Grupo II. Contudo, o percentual de FD foi maior no Grupo I (76,4 ± 12,7% vs. 68,9 ± 10%; p < 0,05) durante o EED, em virtude de o Grupo I apresentar menos componente sistólico. O percentual de FD < 50% ocorreu em todos os casos no pré - operatório, em cinco casos no pós - operatório precoce e em dez casos em condição basal seis meses após a cirurgia. Todavia, durante o EED, todos os casos apresentaram o percentual de FD > 50%, sendo este percentual de 100% em cinco casos (quatro no Grupo I). Os grupos não apresentaram diferença entre as RFCs (1,9 ± 0,46 vs. 2,11 ± 0,56; p = 0,143) ou as RVFCs calculadas com o pico (2,17 ± 0,64 vs.2,28 ± 0,63; p = 0,537) e com a média (2,27 ± 0,54 vs.2,50 ± 0,79; p= 0,232) da velocidade diastólica. Conclusão: Concluímos que o adequado estado funcional da ATI anastomosada independe da presença ou ausência dos importantes ramos proximais. Assim, a ligadura dos ramos não determina aumento do fluxo sistólico, diastólico ou total através deste enxerto, e o predomínio diastólico é mais evidente sob a condição estresse. O aumento dos fluxos sistólico e total indicam para a adaptação do fluxo através desta artéria para suprir a ambas, circulação coronariana e não coronariana, nos pacientes que não têm esses ramos ligados durante a cirurgia. Estes achados apontam para o entendimento de que a hipótese do roubo de fluxo pelos ramos não ligados é improvável / Background: The internal thoracic artery (ITA) \"in situ\" has systolic flow predominance, but when grafted to the left coronary artery system, the ITA becomes a hybrid system with diastolic flow predominance. The relevance of the patency or not-patency of the large proximal branches of the ITA graft is controversial in regards to the possibility of flow steal. During dobutamine stress echocardiography (DSE), the functional status of the ITA graft can be assessed by the coronary reserve in addition to assessment of the distinct effects of DSE on systolic (SF), diastolic (DF), and total flow (TF = systolic + diastolic). Objective: To assess, by Doppler echocardiography, the effects of the significant proximal branches of ITA graft in the flow, coronary flow velocity reserve (CFVR) and coronary flow reserve (CFR), in patients with preserved (> 50%) left ventricular ejection fraction (LVEF). Methods: In a prospective randomized controlled clinical trial we evaluate patients with (Group I) and without (Group II) ligation of important proximal branches of the ITA grafted to the anterior descending coronary artery. Supraclavicular assessment of the ITAs and transthoracic echocardiograms were performed, at rest and during DSE, on pre-operative, early and six months post-operative. In all patients, the submaximal heart rate [(220 - age) x (0.85)] was achieved during DSE with no ischemia to the area matching the ITA graft. The SF, DF, TF and percentage of DF were measured in the four moments of this study. The percentage of DF was calculated by the ratio of the integral of the diastolic flow velocity by the integral of the total flow velocity (systolic + diastolic). The coronary reserve was assessed at six months post-operative, and it was calculated by the ratio of the variable during DSE and at rest, using the maximum and the mean of the diastolic flow velocity to calculate the CFVR; and the TF to calculate the CFR. Student\'s t-tests or Wilcoxon\'s rank sum test (Mann-Whitney) were used to examine differences between the groups in normally distributed or not-normally-distributed continuous variables, respectively. Fisher exact test was used to examine the difference in proportions. A p value < 0.05 was considered statistically significant. Results: Group I (25 patients) and Group II (28 patients) were not different regarding to clinical and echocardiographic characteristics, with preservation of the LVEF in all cases. The DF was not different between the groups in the four moments of this study. However, during the DSE, the SF (19.5 ± 9.3 ml/min vs. 32.7 ± 19.4 ml/min, p < 0.05) and TF (79.1 ± 21.4 ml/min vs. 101 1 ± 47.4 ml/min; p < 0.05) were higher in Group II. On the other hand, during the DSE, the percentage of DF was higher in Group I (76.4 ± 12.7% vs. 68.9 ± 10%; p < 0.05), due to its lower systolic component. The percentage of DF < 50% occurred in all cases in the pre-operative, in five cases in the early post-operative and in ten cases, at rest, six months postoperatively. However, during the DSE, all cases showed the percentage of DF > 50%, furthermore five cases (four in Group I) had the percentage of DF of 100%. There was no difference between the groups in regards to CFR (1.9 ± 0.46 vs. 2.11 ± 0.56; p = 0.143), or CFVR calculated using the maximum (2.17 ± 0.64 vs. 2.28 ± 0.63; p = 0.537) and the mean (2.27 ± 0.54 vs. 2.50 ± 0.79; p = 0.232) of the diastolic velocity. Conclusion: The appropriate functional status of the ITA graft does not depend on the ligation or preservation of important proximal ITA branches. Thus, ligation of ITA branches does not determine increase in systolic, diastolic or total flow through the ITA graft, and its diastolic predominance is more evident under stress. The increase in the systolic and total flow indicates an adaptation of the flow through the ITA graft to supply both coronary and non-coronary systems, in those patients that don\'t have the branches ligated during surgery. These findings point towards the hypothesis that the flow steal by unligated branches is unlikely.
|
15 |
Image based Computational Hemodynamics for Non-invasive and Patient-Specific Assessment of Arterial StenosisMd Monsurul Islam Khan (6911054) 16 October 2019 (has links)
While computed tomographic angiography (CTA) has emerged as a powerful noninvasive option that allows for direct visualization of arterial stenosis(AS), it cant assess the hemodynamic abnormality caused by an AS. Alternatively, trans-stenotic pressure gradient (TSPG) and fractional flow reserve (FFR) are well-validated hemodynamic indices to assess the ischemic severity of an AS. However, they have significant restriction in practice due to invasiveness and high cost. To fill the gap, a new computational modality, called <i>InVascular</i> has been developed for non-invasive quantification TSPG and/or FFR based on patient's CTA, aiming to quantify the hemodynamic abnormality of the stenosis and help to assess the therapeutic/surgical benefits of treatment for the patient. Such a new capability gives rise to a potential of computation aided diagnostics and therapeutics in a patient-specific environment for ASs, which is expected to contribute to precision planning for cardiovascular disease treatment. <i>InVascular</i> integrates a computational modeling of diseases arteries based on CTA and Doppler ultrasonography data, with cutting-edge Graphic Processing Unit (GPU) parallel-computing technology. Revolutionary fast computing speed enables noninvasive quantification of TSPG and/or FFR for an AS within a clinic permissible time frame. In this work, we focus on the implementation of inlet and outlet boundary condition (BC) based on physiological image date and and 3-element Windkessel model as well as lumped parameter network in volumetric lattice Boltzmann method. The application study in real human coronary and renal arterial system demonstrates the reliability of the in vivo pressure quantification through the comparisons of pressure waves between noninvasive computational and invasive measurement. In addition, parametrization of worsening renal arterial stenosis (RAS) and coronary arterial stenosis (CAS) characterized by volumetric lumen reduction (S) enables establishing the correlation between TSPG/FFR and S, from which the ischemic severity of the AS (mild, moderate, or severe) can be identified. In this study, we quantify TSPG and/or FFR for five patient cases with visualized stenosis in coronary and renal arteries and compare the non-invasive computational results with invasive measurement through catheterization. The ischemic severity of each AS is predicted. The results of this study demonstrate the reliability and clinical applicability of <i>InVascular</i>.
|
16 |
Estudo comparativo do fluxo da artéria torácica interna utilizada \"in situ\" na revascularização miocárdica, com e sem a ligadura dos ramos proximais, utilizando a ecocardiografia Doppler / Comparative study of the internal thoracic artery flow used \"in situ\" for myocardial revascularization, with and without ligation of its proximal branches using Doppler echocardiographyJosé Sebastião de Abreu 19 May 2015 (has links)
Fundamento: A artéria torácica interna (ATI) \"in situ\" apresenta predomínio de fluxo sistólico, mas após sua anastomose no sistema coronariano esquerdo torna-se um sistema híbrido com predomínio de fluxo diastólico, sendo a relevância da patência ou não dos grandes ramos proximais da ATI anastomosada controversa quanto à possibilidade de roubo de fluxo. Porém, constata-se que durante o ecocardiograma sob estresse com dobutamina (EED), o estado funcional da ATI anastomosada pode ser avaliado através da reserva coronariana, além da verificação dos distintos efeitos no fluxo sistólico (FS), diastólico (FD) e total (FT = sistólico + diastólico). Objetivo: Verificar por meio da ecocardiografia e Doppler o efeito dos ramos proximais importantes da ATI no fluxo, na reserva de velocidade (RVFC) e de fluxo (RFC) coronariano, em pacientes com fração de ejeção do ventrículo esquerdo (FEVE) preservada (> 50%). Métodos: Em ensaio clínico prospectivo controlado e randomizado, foram avaliados pacientes com (Grupo I) e sem (Grupo II), a ligadura dos ramos proximais importantes da ATI anastomosada na coronária descendente anterior. As avaliações das ATIs em nível supraclavicular e os ecocardiogramas transtorácicos foram realizados no pré-operatório, no pós-operatório precoce, seis meses após a cirurgia em condição basal e durante o EED. Neste, foi alcançada a frequência cardíaca submáxima [(220 - idade) x (0,85)] sem a ocorrência de isquemia no território subjacente à ATI anastomosada em todos os pacientes. Foram medidos o FS, o FD, o FT e o percentual de FD, nos quatro momentos do estudo. O percentual de FD resultou da divisão da integral da velocidade diastólica do fluxo pela integral da velocidade total (sistólica + diastólica) do fluxo. A reserva coronariana foi obtida através do Doppler da ATI anastomosada seis meses após a cirurgia, sendo calculada através da razão entre o valor da variável registrado no EED e em condição basal, utilizando-se para as RVFCs o pico e a média de velocidade diastólica, e para a RFC o FT. As distribuições das variáveis contínuas foram comparadas através do Teste t Student, quando as variáveis eram aproximadamente normais, ou através do Teste da Soma dos Postos de Wilcoxon (Mann-Whitney), quando as variáveis não eram aproximadamente normais. Proporções foram comparadas através do teste exato de Fisher. O valor-p < 0,05 entre os grupos foi considerado estatisticamente significativo. Resultados: O Grupo I (25 pacientes) e o Grupo II (28 pacientes) não foram diferentes quanto às características clínicas e ecocardiográficas, constatando-se a FEVE preservada em todos os casos. O FD não diferiu entre os grupos nos quatro momentos do estudo. Entretanto, verificou-se durante o EED que o FS (19,5 ± 9,3 ml/min vs. 32,7 ± 19,4 ml/min; p < 0,05) e o FT (79,1 ± 21,4 ml/min vs. 101,1 ± 47,4 ml/min; p < 0,05) foram maiores no Grupo II. Contudo, o percentual de FD foi maior no Grupo I (76,4 ± 12,7% vs. 68,9 ± 10%; p < 0,05) durante o EED, em virtude de o Grupo I apresentar menos componente sistólico. O percentual de FD < 50% ocorreu em todos os casos no pré - operatório, em cinco casos no pós - operatório precoce e em dez casos em condição basal seis meses após a cirurgia. Todavia, durante o EED, todos os casos apresentaram o percentual de FD > 50%, sendo este percentual de 100% em cinco casos (quatro no Grupo I). Os grupos não apresentaram diferença entre as RFCs (1,9 ± 0,46 vs. 2,11 ± 0,56; p = 0,143) ou as RVFCs calculadas com o pico (2,17 ± 0,64 vs.2,28 ± 0,63; p = 0,537) e com a média (2,27 ± 0,54 vs.2,50 ± 0,79; p= 0,232) da velocidade diastólica. Conclusão: Concluímos que o adequado estado funcional da ATI anastomosada independe da presença ou ausência dos importantes ramos proximais. Assim, a ligadura dos ramos não determina aumento do fluxo sistólico, diastólico ou total através deste enxerto, e o predomínio diastólico é mais evidente sob a condição estresse. O aumento dos fluxos sistólico e total indicam para a adaptação do fluxo através desta artéria para suprir a ambas, circulação coronariana e não coronariana, nos pacientes que não têm esses ramos ligados durante a cirurgia. Estes achados apontam para o entendimento de que a hipótese do roubo de fluxo pelos ramos não ligados é improvável / Background: The internal thoracic artery (ITA) \"in situ\" has systolic flow predominance, but when grafted to the left coronary artery system, the ITA becomes a hybrid system with diastolic flow predominance. The relevance of the patency or not-patency of the large proximal branches of the ITA graft is controversial in regards to the possibility of flow steal. During dobutamine stress echocardiography (DSE), the functional status of the ITA graft can be assessed by the coronary reserve in addition to assessment of the distinct effects of DSE on systolic (SF), diastolic (DF), and total flow (TF = systolic + diastolic). Objective: To assess, by Doppler echocardiography, the effects of the significant proximal branches of ITA graft in the flow, coronary flow velocity reserve (CFVR) and coronary flow reserve (CFR), in patients with preserved (> 50%) left ventricular ejection fraction (LVEF). Methods: In a prospective randomized controlled clinical trial we evaluate patients with (Group I) and without (Group II) ligation of important proximal branches of the ITA grafted to the anterior descending coronary artery. Supraclavicular assessment of the ITAs and transthoracic echocardiograms were performed, at rest and during DSE, on pre-operative, early and six months post-operative. In all patients, the submaximal heart rate [(220 - age) x (0.85)] was achieved during DSE with no ischemia to the area matching the ITA graft. The SF, DF, TF and percentage of DF were measured in the four moments of this study. The percentage of DF was calculated by the ratio of the integral of the diastolic flow velocity by the integral of the total flow velocity (systolic + diastolic). The coronary reserve was assessed at six months post-operative, and it was calculated by the ratio of the variable during DSE and at rest, using the maximum and the mean of the diastolic flow velocity to calculate the CFVR; and the TF to calculate the CFR. Student\'s t-tests or Wilcoxon\'s rank sum test (Mann-Whitney) were used to examine differences between the groups in normally distributed or not-normally-distributed continuous variables, respectively. Fisher exact test was used to examine the difference in proportions. A p value < 0.05 was considered statistically significant. Results: Group I (25 patients) and Group II (28 patients) were not different regarding to clinical and echocardiographic characteristics, with preservation of the LVEF in all cases. The DF was not different between the groups in the four moments of this study. However, during the DSE, the SF (19.5 ± 9.3 ml/min vs. 32.7 ± 19.4 ml/min, p < 0.05) and TF (79.1 ± 21.4 ml/min vs. 101 1 ± 47.4 ml/min; p < 0.05) were higher in Group II. On the other hand, during the DSE, the percentage of DF was higher in Group I (76.4 ± 12.7% vs. 68.9 ± 10%; p < 0.05), due to its lower systolic component. The percentage of DF < 50% occurred in all cases in the pre-operative, in five cases in the early post-operative and in ten cases, at rest, six months postoperatively. However, during the DSE, all cases showed the percentage of DF > 50%, furthermore five cases (four in Group I) had the percentage of DF of 100%. There was no difference between the groups in regards to CFR (1.9 ± 0.46 vs. 2.11 ± 0.56; p = 0.143), or CFVR calculated using the maximum (2.17 ± 0.64 vs. 2.28 ± 0.63; p = 0.537) and the mean (2.27 ± 0.54 vs. 2.50 ± 0.79; p = 0.232) of the diastolic velocity. Conclusion: The appropriate functional status of the ITA graft does not depend on the ligation or preservation of important proximal ITA branches. Thus, ligation of ITA branches does not determine increase in systolic, diastolic or total flow through the ITA graft, and its diastolic predominance is more evident under stress. The increase in the systolic and total flow indicates an adaptation of the flow through the ITA graft to supply both coronary and non-coronary systems, in those patients that don\'t have the branches ligated during surgery. These findings point towards the hypothesis that the flow steal by unligated branches is unlikely.
|
17 |
Valor prognóstico da reserva de fluxo coronário e miocárdico obtida pela ecocardiografia contrastada em pacientes com cardiomiopatia dilatada de origem não isquêmica / Prognostic value of coronary and myocardial flow reserve obtained by contrast echocardiography in patients with nonischemic dilated cardiomyopathyMarta Fernandes Lima 14 May 2012 (has links)
Apesar dos avanços no entendimento da fisiopatologia e dos recursos terapêuticos atualmente disponíveis, a cardiomiopatia dilatada (CMD) permanece como uma condição com alta mortalidade, sendo que a disfunção microvascular é um dos mecanismos relacionados à piora da função cardíaca. Nos últimos anos, novas técnicas de ecocardiografia vêm sendo utilizadas para avaliação da disfunção microvascular, incluindo a medida de velocidade de fluxo coronário pelo Doppler da artéria coronária descendente anterior (ADA), e a análise quantitativa do fluxo miocárdico pela ecocardiografia com perfusão miocárdica em tempo-real (EPMTR). No presente estudo, avaliamos o valor prognóstico da reserva de velocidade de fluxo coronário (RVFC), obtida pelo Doppler da ADA, e da reserva de fluxo miocárdico (RFM), obtida pela EPMTR, para predizer morte e transplante cardíaco em pacientes com CMD de origem não isquêmica. Adicionalmente, avaliamos se as medidas de reserva de fluxo acrescentam valor prognóstico sobre variáveis clínicas e ecocardiográficas que já são conhecidas como preditores de eventos nesta população. Estudamos 195 pacientes com CMD (130 homens, média etária 54 ± 12 anos) que apresentavam fração de ejeção do ventrículo esquerdo inferior a 35% pelo ecocardiograma e ausência de sinais de doença arterial coronária obstrutiva por angiografia coronária invasiva ou por método não invasivo (cintilografia de perfusão miocárdica ou angiotomografia de coronárias). Foram analisados parâmetros ecocardiográficos convencionais de função sistólica e diastólica do ventrículo esquerdo em repouso. A velocidade de fluxo coronário foi determinada pelo Doppler pulsado na ADA e a dinâmica das microbolhas no miocárdio foi quantificada pela EPMTR utilizando programas computacionais específicos, tanto em repouso como durante o estresse pelo dipiridamol (0,84 mg/Kg). As RVFC, RFM e reserva de velocidade de repreenchimento de microbolhas no miocárdio (reserva ) foram obtidas pela relação entre os parâmetros de fluxo durante a hiperemia e em repouso, sendo consideradas diminuídas quando os valores estavam abaixo de 2,0. O tempo médio de acompanhamento foi de 29 meses (variando de 6 a 69 meses). Neste período, 45 pacientes (24%) apresentaram eventos, sendo 43 mortes de causa cardíaca e 2 transplantes cardíacos. Na análise univariada foram preditores de eventos: etiologia chagásica, classe funcional de insuficiência cardíaca, uso de inibidores da enzima conversora de angiotensina e/ou bloqueadores dos receptores de angiotensina II (fator protetor), diâmetros ventriculares e do átrio esquerdo, volumes ventriculares, fração de ejeção, disfunção diastólica, grau de insuficiência mitral, RVFC, RFM e reserva . Na análise multivariada, foram preditores independentes de eventos o diâmetro do átrio esquerdo (razão de chances = 1,16 por unidade de aumento; intervalo de confiança 95% = 1,078 1,264; p<0,001) e a reserva diminuída (razão de chances = 3,219; intervalo de confiança 95% = 1,178 8,795; p<0,001). No modelo sequencial de predição de eventos, fração de ejeção e diâmetro do átrio esquerdo adicionaram valor prognóstico às variáveis clínicas (aumento do qui-quadrado de 15,2 para 58,5; p < 0,001). A reserva adicionou poder ao modelo (qui-quadrado de 70,2; p<0,001). Concluímos que tanto a RVFC, obtida pelo Doppler da ADA, como a RFM e reserva , obtidas pela EPMTR sob estresse pelo dipiridamol, são preditoras de morte e transplante cardíaco em pacientes com CMD não isquêmica. Entretanto, somente o diâmetro do átrio esquerdo e a reserva mostraram valor prognóstico independente e incremental sobre variáveis clínicas e ecocardiográficas que já são conhecidas como preditores de eventos nesta população / Despite advances in understanding of the pathophysiology and therapeutic approaches, dilated cardiomyopathy (DCM) remains as a condition with high mortality and one of the mechanisms involved in this process seems to be microvascular dysfunction. Recently, new echocardiographic techniques have been incorporated in the clinical practice and used for the assessment of microvascular dysfunction, including evaluation of left anterior descending coronary artery (LAD) by Doppler and quantitative analysis of myocardial flow by real-time myocardial perfusion echocardiography (RTMPE). In the present study, we evaluated the prognostic value of coronary flow velocity reserve (CFVR), obtained by transthoracic echocardiography, and parameters of myocardial flow reserve (MFR), obtained by RTMPE for predicting cardiac death and heart transplantation in patients with nonischemic DCM. In addition, we sought to detect the incremental value of flow reserve over clinical and echocardiographic parameters already known as predictors of events in this population. We studied 195 patients with DCM (130 men, mean age 54 ± 12 years) who had left ventricular ejection fraction (LVEF) less than 35% by echocardiography and no signs of obstructive coronary artery disease by invasive coronary angiography or noninvasive methods (nuclear medicine or angiography by computed tomography). We assessed conventional echocardiographic parameters of systolic and diastolic left ventricular function at rest. Coronary flow velocity was determined by pulsed Doppler in LAD and dynamics of microbubbles in the myocardium was measured by RTMPE using specific computer programs, both at rest and during dipyridamole stress (0.84 mg/kg). CFVR, MFR and the reserve of velocity of microbubbles in the myocardium ( reserve) were obtained as the ratio between parameters of flow during hyperemia and at rest, being considered abnormal when these were below 2.0. The mean follow-up was 29 months (ranging from 6 to 69 months). During this period, 45 patients (24%) had events, 43 cardiac deaths and 2 heart transplantations. In the univariate analysis, predictors of events were: Chagas disease, New York Heart Association functional class, use of angiotensin-converting enzyme inhibitors/angiotensin II receptor blocker (protective effect), left ventricular and atrial diameters, left ventricular volumes, LVEF, diastolic dysfunction, degree of mitral regurgitation, CVFR, MFR and reserve. By multivariate analysis, the only independent predictors of events were the left atrial diameter (OR = 1.16, 95% confidence interval = 1.078 to 1.264, p <0.001) and reserve 2.0 (OR = 3.219, confidence interval 95 % = 1.178 to 8.795, p <0.001). In the sequential model of events prediction, LVEF and left atrial diameter added prognostic value over clinical factors (chi-square from 15.2 to 58.5; p<0.001). reserve added power to the model (chi-square = 70.2, p<0.001). We concluded that CVFR, obtained by Doppler in LAD, MFR and reserve, obtained by dipyridamole stress RTMPE, are predictors of cardiac death and heart transplantation in patients with nonischemic DCM. However, only left atrial diameter and depressed reserve showed independent and incremental predictive value beyond that provided by current known prognostic clinical and echocardiographic factors
|
18 |
Processamento de imagens médicas e parâmetros hemodinâmicos: validação clínica de modelos cardiovasculares assistidos por computação científica / Processing of medical imaging and hemodynamic parameters: clinicalBezerra, Cristiano Guedes 16 March 2018 (has links)
Introdução: A doença arterial coronária (DAC) é avaliada através dos aspectos anatômicos da placa aterosclerótica ou a partir da repercussão funcional da estenose, por métodos diagnósticos diversos. O ultrassom intravascular (IVUS) fornece uma avaliação anatômica precisa do lúmen e da parede do vaso, tendo sido validado como uma ferramenta útil para guiar a intervenção coronária percutânea (ICP). No entanto, do ponto de vista diagnóstico, o IVUS representa mal o estado funcional (isto é, informação relacionada ao comprometimento de fluxo) do vaso interrogado. A reserva de fluxo fracionada (FFR) é método importante para identificação de isquemia, discriminando as estenoses coronárias que podem se beneficiar de ICP. Objetivamos desenvolver e avaliar o desempenho diagnóstico de um novo algoritmo computacional para estimar a FFR à partir das imagens do IVUS tridimensional (IVUSFR), comparando-o com o método padrão ouro para estimação de fluxo coronário invasivo (FFRPW). Métodos: Pacientes com DAC estável conhecida ou suspeita encaminhados para cateterismo cardíaco eletivo foram submetidos a avaliação complementar com medida de fluxo coronário pelo FFRPW e com imagem intravascular pelo IVUS, no mesmo procedimento, a fim de avaliar lesões intermediárias. As imagens do IVUS foram processadas para gerar uma malha computacional tridimensional que condensa as características geométricas do vaso. O IVUSFR foi obtido utilizando dinâmica de fluido computacional, configurando-se as condições de contorno a partir de características específicas do paciente e do território coronário irrigado. As medidas de FFRPW foram dicotomizadas no limiar de 0,80 para definir lesões hemodinamicamente significativas e avaliar o desempenho diagnóstico do IVUSFR. Resultados: Um total de 34 artérias coronárias de 24 pacientes foi analisado. A área luminal mínima média avaliada pelo IVUS de 4,14 ± 1,74 mm2, e carga de placa média de 66±10% caracterizam o grau intermediário das lesões. O IVUSFR correlacionou significativamente (r = 0,79; p < 0,001) e mostrou boa concordância com a FFRPW, apresentando diferença média de -0,008 ± 0,067 (p = 0,47). O IVUSFR apresentou acurácia, sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo de 91%, 89%, 92%, 80% e 96%, respectivamente, para detectar estenoses hemodinamicamente significativas. Conclusão: O processamento computacional do IVUSFR é um novo método que permite a avaliação funcional da estenose coronária intermediária de forma acurada, enriquecendo as informações anatômicas do IVUS / Introduction: Coronary artery disease (CAD) is assessed through the anatomical aspects of the atherosclerotic plaque or through the functional impairment of the stenosis, by different diagnostic methods. Intravascular ultrasound (IVUS) provides accurate anatomic assessment of lumen and vessel wall and has been validated as a useful tool to guide percutaneous coronary intervention (PCI). However, from the diagnostic point of view, IVUS poorly represents the functional status (i.e. flow-related information) of the imaged vessel. Fractional flow reserve (FFR) is an important tool to identify ischemia, discriminating coronary stenosis that may benefit from PCI. We aimed to develop and evaluate the diagnostic performance of a novel computational algorithm based on three-dimensional IVUS imaging in estimating fractional flow reserve (IVUSFR), compared to gold-standard invasive measurements (FFRPW). Methods: Patients with known or suspected stable coronary disease scheduled for elective cardiac catheterization underwent FFRPW measurement and IVUS imaging in the same procedure to evaluate intermediate lesions. A processing methodology was applied on IVUS to generate a computational mesh condensing the geometric characteristics of the vessel. Through computational fluid dynamics, IVUSFR was obtained from patient-level morphological definition of arterial districts and from territory-specific boundary conditions. FFRPW measurements were dichotomized at the 0.80 thresholds to define hemodynamically significant lesions and evaluate diagnostic performance of IVUSFR. Results: A total of 24 patients with 34 vessels were analyzed. The mean minimum luminal area assessed by IVUS was 4.14 ± 1.74 mm2, and mean plaque burden was 66 ± 10%, characterizing intermediate lesions. IVUSFR significantly correlated (r = 0.79; p < 0.001) and showed good agreement with FFRPW, with a mean difference of -0.008 ± 0.067 (p = 0.47). IVUSFR presented an overall accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 91%, 89%, 92%, 80%, and 96% respectively to detect significant stenosis. Conclusion: The computational processing of IVUSFR is a new method that allows the evaluation of the functional significance of coronary stenosis in an accurate way, enriching the anatomical information of IVUS
|
19 |
Processamento de imagens médicas e parâmetros hemodinâmicos: validação clínica de modelos cardiovasculares assistidos por computação científica / Processing of medical imaging and hemodynamic parameters: clinicalCristiano Guedes Bezerra 16 March 2018 (has links)
Introdução: A doença arterial coronária (DAC) é avaliada através dos aspectos anatômicos da placa aterosclerótica ou a partir da repercussão funcional da estenose, por métodos diagnósticos diversos. O ultrassom intravascular (IVUS) fornece uma avaliação anatômica precisa do lúmen e da parede do vaso, tendo sido validado como uma ferramenta útil para guiar a intervenção coronária percutânea (ICP). No entanto, do ponto de vista diagnóstico, o IVUS representa mal o estado funcional (isto é, informação relacionada ao comprometimento de fluxo) do vaso interrogado. A reserva de fluxo fracionada (FFR) é método importante para identificação de isquemia, discriminando as estenoses coronárias que podem se beneficiar de ICP. Objetivamos desenvolver e avaliar o desempenho diagnóstico de um novo algoritmo computacional para estimar a FFR à partir das imagens do IVUS tridimensional (IVUSFR), comparando-o com o método padrão ouro para estimação de fluxo coronário invasivo (FFRPW). Métodos: Pacientes com DAC estável conhecida ou suspeita encaminhados para cateterismo cardíaco eletivo foram submetidos a avaliação complementar com medida de fluxo coronário pelo FFRPW e com imagem intravascular pelo IVUS, no mesmo procedimento, a fim de avaliar lesões intermediárias. As imagens do IVUS foram processadas para gerar uma malha computacional tridimensional que condensa as características geométricas do vaso. O IVUSFR foi obtido utilizando dinâmica de fluido computacional, configurando-se as condições de contorno a partir de características específicas do paciente e do território coronário irrigado. As medidas de FFRPW foram dicotomizadas no limiar de 0,80 para definir lesões hemodinamicamente significativas e avaliar o desempenho diagnóstico do IVUSFR. Resultados: Um total de 34 artérias coronárias de 24 pacientes foi analisado. A área luminal mínima média avaliada pelo IVUS de 4,14 ± 1,74 mm2, e carga de placa média de 66±10% caracterizam o grau intermediário das lesões. O IVUSFR correlacionou significativamente (r = 0,79; p < 0,001) e mostrou boa concordância com a FFRPW, apresentando diferença média de -0,008 ± 0,067 (p = 0,47). O IVUSFR apresentou acurácia, sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo de 91%, 89%, 92%, 80% e 96%, respectivamente, para detectar estenoses hemodinamicamente significativas. Conclusão: O processamento computacional do IVUSFR é um novo método que permite a avaliação funcional da estenose coronária intermediária de forma acurada, enriquecendo as informações anatômicas do IVUS / Introduction: Coronary artery disease (CAD) is assessed through the anatomical aspects of the atherosclerotic plaque or through the functional impairment of the stenosis, by different diagnostic methods. Intravascular ultrasound (IVUS) provides accurate anatomic assessment of lumen and vessel wall and has been validated as a useful tool to guide percutaneous coronary intervention (PCI). However, from the diagnostic point of view, IVUS poorly represents the functional status (i.e. flow-related information) of the imaged vessel. Fractional flow reserve (FFR) is an important tool to identify ischemia, discriminating coronary stenosis that may benefit from PCI. We aimed to develop and evaluate the diagnostic performance of a novel computational algorithm based on three-dimensional IVUS imaging in estimating fractional flow reserve (IVUSFR), compared to gold-standard invasive measurements (FFRPW). Methods: Patients with known or suspected stable coronary disease scheduled for elective cardiac catheterization underwent FFRPW measurement and IVUS imaging in the same procedure to evaluate intermediate lesions. A processing methodology was applied on IVUS to generate a computational mesh condensing the geometric characteristics of the vessel. Through computational fluid dynamics, IVUSFR was obtained from patient-level morphological definition of arterial districts and from territory-specific boundary conditions. FFRPW measurements were dichotomized at the 0.80 thresholds to define hemodynamically significant lesions and evaluate diagnostic performance of IVUSFR. Results: A total of 24 patients with 34 vessels were analyzed. The mean minimum luminal area assessed by IVUS was 4.14 ± 1.74 mm2, and mean plaque burden was 66 ± 10%, characterizing intermediate lesions. IVUSFR significantly correlated (r = 0.79; p < 0.001) and showed good agreement with FFRPW, with a mean difference of -0.008 ± 0.067 (p = 0.47). IVUSFR presented an overall accuracy, sensitivity, specificity, positive predictive value, and negative predictive value of 91%, 89%, 92%, 80%, and 96% respectively to detect significant stenosis. Conclusion: The computational processing of IVUSFR is a new method that allows the evaluation of the functional significance of coronary stenosis in an accurate way, enriching the anatomical information of IVUS
|
20 |
Eficácia da aplicação de ondas de choque para indução ao crescimento vascular em pacientes com angina refratária: avaliação pela ecocardiografia de perfusão miocádica em tempo real / Efficiency of shock wave application to induce vascular growth in patients with refractory angina: assessment by real-time myocardial perfusion echocardiographyCeccon, Conrado Lelis 06 April 2018 (has links)
A doença arterial coronariana crônica apresenta alta prevalência e morbidade na população, manifestando-se como uma síndrome clínica caracterizada por sintomas álgicos tipicamente desencadeados ou agravados pelo esforço físico - a angina. Define-se a angina como refratária na presença de isquemia miocárdica documentada não passível de tratamento por meio de revascularização e não controlada a despeito do tratamento farmacológico máximo tolerado. O uso de terapia com ondas de choque extracorpóreas no tratamento da isquemia miocárdica tem sido proposto como uma alternativa promissora para o alívio dos sintomas anginosos e melhora da carga isquêmica por meio da promoção de vasodilatação e neoangiogênese. No presente estudo, avaliamos o efeito da terapia guiada com ondas de choque na reserva de fluxo miocárdico, obtida pela ecocardiografia de perfusão miocárdica em tempo real (EPMTR), em pacientes com angina refratária. Determinamos, também, as implicações da terapia com ondas de choque nas variáveis clínicas por meio da avaliação da classe funcional de angina pelo escore da Canadian Cardiovascular Society (CCS), capacidade funcional pelo escore de insuficiência cardíaca da New York Heart Association (NYHA) e qualidade de vida pelo Seattle Angina Questionnaire (SAQ), assim como nas variáveis ecocardiográficas. Foram estudados 15 pacientes com angina refratária procedentes do Ambulatório de Angina Refratária do Instituto do Coração (InCor, HC-FMUSP), os quais foram submetidos a 9 sessões de terapia com ondas de choque, ao longo de 9 semanas, e acompanhados por um período de 6 meses após a conclusão do tratamento. A dinâmica das microbolhas no miocárdio foi quantificada pela EPMTR utilizando programas computacionais específicos, tanto em repouso como durante o estresse pelo dipiridamol (0,84 mg/Kg). A reserva de volume miocárdico normatizada (Anor), a reserva de velocidade de repreenchimento de microbolhas no miocárdio (?) e a reserva de fluxo miocárdico (Anor x ?) foram obtidas pela relação entre os parâmetros de fluxo durante a hiperemia e o repouso, antes e 6 meses após o tratamento com ondas de choque. Nos 15 pacientes incluídos no estudo, avaliamos 32 segmentos com isquemia miocárdica submetidos à terapia, 31 segmentos com isquemia miocárdica não submetidos à terapia e 60 segmentos não isquêmicos. Os pesquisadores que realizaram as quantificações da EPMTR não tinham conhecimento dos dados clínicos no momento da análise de perfusão. A média etária da amostra foi de 61,5 (± 12,8) anos com predomínio do sexo masculino (67%), sendo que 93% deles apresentavam doença multiarterial. Após 6 meses da conclusão da terapia com ondas de choque, foi observada uma melhora da classe de angina (CCS) de 3,20 ± 0,56 para 1,93 ± 0,70 (p = 0,0001) e de insuficiência cardíaca (NYHA) de 2,8 ± 0,56 para 2,33 ± 0,81 (p = 0,048), resultados que foram concordantes com os achados do SAQ, o qual evidenciou melhora significativa da pontuação em todas as categorias (análise global com incremento da pontuação média de 42,33 ± 13,0 para 71,16 ± 14,3; p = 0,0001). Houve uma variação da fração de ejeção do ventrículo esquerdo de 50,30 ± 13,1% para 53,20 ± 10,6% (p = 0,049) na ausência de alterações no diâmetro diastólico final (de 53,80 ± 6,61 mm para 53,53 ± 7,05 mm; p = 0,81), no volume diastólico final (de 134,67 ± 34,33 mL para 146,13 ± 59,45 mL; p = 0,29) ou na função diastólica. A análise da perfusão miocárdica pela EPMTR evidenciou um aumento significativo da reserva de fluxo miocárdico (Anor x ?) de 1,33 ± 0,22 para 1,74 ± 0,29 (p = 0,0001) e também da reserva Anor de 1,02 ± 0,21 para 1,24 ± 0,33 (p = 0,004) nos segmentos isquêmicos submetidos à terapia com ondas de choque, mas não da reserva beta (de 1,33 ± 0,24 para 1,47 ± 0,35; p = 0,055). Não houve alterações significativas na perfusão miocárdica nos segmentos isquêmicos não tratados ou nos segmentos não isquêmicos. A análise global demonstrou uma melhora na reserva de fluxo miocárdico (de 1,78 ± 0,54 para 1,89 ± 0,49; p = 0,017) e na reserva beta (de 1,63 ± 0,43 para 1,70 ± 0,40; p = 0,039). Não foram registrados eventos cardiovasculares maiores durante o período de acompanhamento. Concluímos que a EPMTR foi capaz de identificar melhora da reserva de fluxo miocárdico nos segmentos submetidos à terapia com ondas de choque, possivelmente devido à neoproliferação vascular. Os resultados sugerem que a terapia com ondas de choque em pacientes com angina refratária é segura e tem o potencial de melhorar a isquemia miocárdica nos segmentos isquêmicos tratados, com impacto nos sintomas e na qualidade de vida / Chronic coronary artery disease shows high prevalence and morbidity levels in general population. In the clinical scenario, it is usually characterized by pain symptoms typically triggered or aggravated by physical effort - the angina. Refractory angina is defined as a documented and uncontrolled myocardial ischemia, untreatable by revascularization, despite maximum tolerated drug therapy. The use of extracorporeal cardiac shock wave therapy to treat myocardial ischemia has been suggested as a promising alternative to relieve angina symptoms and improve the ischemic load by promoting vasodilation and neoangiogenic phenomena. In the present study, we evaluated the effect of guided shock wave therapy on myocardial flow reserve, determined by real-time myocardial perfusion echocardiography (RTMPE), in patients with refractory angina. We also evaluated the implications of shock wave therapy in clinical variables by assessing the Canadian Cardiovascular Society (CCS) grading of angina pectoris, New York Heart Association (NYHA) functional classification and quality of life by the Seattle Angina Questionnaire (SAQ), as well as echocardiographic variables. Fifteen patients with refractory angina, from the refractory angina outpatient clinic of the Instituto do Coração (InCor, HC-FMUSP), were studied. Each patient underwent 9 shock wave therapy sessions over the course of 9 weeks and was followed for 6 months once the treatment was concluded. Using specific software, myocardial microbubble dynamics was quantified by RTMPE at rest as well as in stress by dipyridamole (0.84 mg/Kg). Normalized myocardial blood (Anor) reserve, myocardium microbubbles replenishment rate (?) reserve and myocardial flow reserve (Anor x ?) were obtained by the ratio of flow parameters during hyperemia and rest, before and 6 months after treatment. In the 15 patients included in the study, we evaluated 32 segments with myocardial ischemia submitted to therapy, 31 segments with myocardial ischemia not submitted to therapy and 60 non-ischemic segments. Researchers were blinded to all clinical data at the time of the perfusion analysis. Patients had mean age of 61.5 (± 12.8) years old, were predominantly men (67%), and 93% presented multiarterial disease. Six months after the completion of shock wave therapy, an improvement in CCS grading of angina pectoris was observed from 3.20 ± 0.56 to 1.93 ± 0.70 (p = 0.0001) and in NYHA functional classification (from 2.80 ± 0.56 to 2.33 ± 0.81; p = 0.048), results consistent with those found by SAQ, which evidenced a significant score improvement in all categories (global analysis with average score increased from 42.33 ± 13.0 to 71.16 ± 14.3; p = 0.0001). There was a variation in the left ventricular ejection fraction (from 50.3 ± 13.1% to 53.20 ± 10.6%; p = 0.049) in the absence of changes in end-diastolic diameter (from 53.80 ± 6.61 mm to 53.53 ± 7.05 mm; p = 0.81), the end-diastolic volume (from 134.67 ± 34.33 mL to 146.13 ± 59.45 mL; p = 0.29) or the diastolic function. Myocardial perfusion analysis by RTMPE evidenced a relevant increase in myocardial flow reserve (Anor x ?) from 1.33 ± 0.22 to 1.74 ± 0.29; p = 0.0001, as well as in the Anor reserve from 1.02 ± 0.21 to 1.24 ± 0.33 (p = 0.004) in ischemic segments submitted to shock wave therapy, but not in ? reserve (from 1.33 ± 0.24 to 1.47 ± 0.35; p = 0.055). There was no significant myocardial perfusion alteration in untreated ischemic segments or non-ischemic segments. Global analysis showed an improvement in myocardial flow reserve (from 1.78 ± 0.54 to 1.89 ± 0.49; p = 0.017) and ? reserve (1.63 ± 0.43 to 1.70 ± 0.40; p = 0.039). No major cardiac events were registered during the follow-up period. We concluded that RTMPE was able to identify an increase in myocardial flow reserve in the segments submitted to shock wave therapy, possibly due to vascular neoproliferation. Results suggest that shock wave therapy on patients with refractory angina is safe, with the potential to improve myocardial ischemia on treated ischemic segments, and positively affect symptoms and quality of life
|
Page generated in 0.0691 seconds