• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 39
  • 39
  • 22
  • 13
  • 12
  • 8
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Experimental investigation of bubble behaviours in domestic heat pump water heating system

Qin, Jianbo January 2018 (has links)
The growing awareness of global warming potential has internationally aroused interest and demand in reducing greenhouse gas emissions produced by human activity. Each year, the UK consumes a significant amount of energy for residential and industrial space heating and domestic hot water production. At present, gas boilers are mostly installed in the domestic water heating which contributes significantly to excessive CO2 emissions and consumption of primary energy resources. However, air-source heat pump system has higher performance efficiency comparing to the traditional gas boiler, which can reduce the carbon dioxide emission and the usage of primary energy resources. The coefficient of efficiency of the heat pump can be range from 2 to 4.5 in various situations. The market shares of heat pump have been predicted to increase in the coming years to meet the requirement of the European Union Commission. There were about 22,000 heat pumps set up in the UK with 18 percent growth comparing to 2016 as reported by BSRIA. A range from 0.6 to 5.7 million heat pumps are estimated by the National Grid to be set up by 2030 to increase the energy efficiency of the UK. Although the energy efficiency of the heat pump is extremely high, there is still a space for improvement in air-source heat pump water heating system. The performance of the heat pump water heating system can be further enhanced if the dissolved gases in its hot water circuit can be efficiently discharged. The undissolved bubbles can stack in a specific position of the radiator, which would cause the cold spot. This could immensely reduce the efficiency of the heat pump water heating system. To avoid this happening, the bubble behaviors in the heat pump water heating system need to be extensively investigated. The better understanding of the bubble behaviors in an air-source heat pump water heating system can contribute to the design of an air evacuation valve and heat pump piping systems. In this thesis, the effects of various heat pump hot water side parameters on gas microbubble diameters and bubble productions were measured and analyzed by varying different experimental conditions. Correspondingly, a summarized conclusion has been presented to predict the gas microbubble's diameter distributions and volumetric void fraction distributions at different operating conditions. These parameters include various system pressures, water flow rates, and saturation ratios. In this thesis, the main results showed that larger average bubble diameter is at the higher water flow rates at heat pump exit. At 2.2 bar condition, when system water flow rate increased from 800 l/h to 1150 l/h, the average bubble diameter increased from 0.086 mm to 0.108 mm. Moreover, the average bubble diameters increase along with the decrease in system pressures. At 1000 l/h condition, when system pressure increased from 2.2 bar to 2.7 bar, the average bubble diameter decreased from 0.100 mm to 0.087 mm. At 850 l/h condition, when system pressure increased from 1.7 bar to 2.5 bar, the average bubble diameter decreased from 0.101 mm to 0.081 mm. In addition, the average bubble diameters slightly increase along with the increase in saturation ratio. Besides, a prediction equation for the bubble diameter distribution in the water pipe was proposed. At SR 1.15 and 2.5 bar condition, when water flow rate increased from 900 l/h to 1100 l/h, volumetric void fraction decreased from 2.25 E-05 to 4.83 E-06. However, at 1000 l/h and SR 1.15 condition, when system pressure increased from 2.2 bar to 2.7 bar, volumetric void fraction decreased from 2.16 E-05 to 3.78 E-06. It is found that the highest city main saturation ratio was achieved at 1.07 at the specific environmental condition.
12

The Development of Unique Focal Planes for High-Resolution Suborbital and Ground-Based Exploration

January 2019 (has links)
abstract: The development of new Ultra-Violet/Visible/IR range (UV/Vis/IR) astronomical instrumentation that use novel approaches for imaging and increase the accessibility of observing time for more research groups is essential for rapid innovation within the community. Unique focal planes that are rapid-prototyped, low cost, and provide high resolution are key. In this dissertation the emergent designs of three unique focal planes are discussed. These focal planes were each designed for a different astronomical platform: suborbital balloon, suborbital rocket, and ground-based observatory. The balloon-based payload is a hexapod-actuated focal plane that uses tip-tilt motion to increase angular resolution through the removal of jitter – known as the HExapod Resolution-Enhancement SYstem (HERESY), the suborbital rocket imaging payload is a Jet Propulsion Laboratory (JPL) delta-doped charge-coupled device (CCD) packaged to survive the rigors of launch and image far-ultra-violet (FUV) spectra, and the ground-based observatory payload is a star centroid tracking modification to the balloon version of HERESY for the tip-tilt correction of atmospheric turbulence. The design, construction, verification, and validation of each focal plane payload is discussed in detail. For HERESY’s balloon implementation, pointing error data from the Stratospheric Terahertz Observatory (STO) Antarctic balloon mission was used to form an experimental lab test setup to demonstrate the hexapod can eliminate jitter in flight-like conditions. For the suborbital rocket focal plane, a harsh set of unit-level tests to ensure the payload could survive launch and space conditions, as well as the characterization and optimization of the JPL detector, are detailed. Finally, a modification of co-mounting a fast-read detector to the HERESY focal plane, for use on ground-based observatories, intended to reduce atmospherically induced tip-tilt error through the centroid tracking of bright natural guidestars, is described. / Dissertation/Thesis / Doctoral Dissertation Exploration Systems Design 2019
13

Ensemble Monte Carlo Simulation Of Quantum Well Infrared Photodetectors, And Inp Based Long Wavelength Quantum Well Infrared Photodetectors For Thermal Imaging

Cellek, Oray Orkun 01 September 2006 (has links) (PDF)
Quantum well infrared photodetectors (QWIP) utilize quantum wells of large bandgap materials to detect infrared radiation. When compared to conventional low bandgap LWIR photodetectors, the QWIP technology offers largest format thermal imagers with much better uniformity. The theoretical part of this study includes the development of a QWIP ensemble Monte Carlo simulator. Capture paths of electrons to quantum wells are simulated in detail. For standard AlGaAs/GaAs QWIPs, at medium and high E-fields L valley quantum well (QW) is a trap for electrons which causes higher capture probability when compared with InP/InGaAs and GaAs/InGaAs QWIPs. The results suggest that high photoconductive gain observed in InP/InGaAs and GaAs/InGaAs QWIPs is not due to good transport properties of binary barrier material but due to higher &amp / #61511 / -L valley energy separation. The experimental part of the study includes the fabrication and characterization of InP/InGaAs and InP/InGaAsP QWIPs and 640x512 FPAs with the main objective of investigating the feasibility of these material systems for QWIPs. The InP/InGaAs and InP/InGaAsP QWIP detectors showed specific detectivity values above 1x1010 cm.Hz1/2/W (70K, f/2, background limited). The devices offer higher allowable system noise floor when compared with the standard AlGaAs/GaAs QWIP technology. It is also experimentally shown that for strategic applications LWIR InP based QWIPs have advantages over the standard QWIP technology. The InP/InGaAs 640x512 QWIP FPA reached 36 mK average NETD value at 70 K with f/1.5 optics and 10 ms integration time. The InP/InGaAsP QWIP on the other hand yielded 38 mK NETD histogram peak at 70 K with f/1.5 optics and 5 ms integration time on 320x256 window of the 640x512 FPA.
14

Insb And Inassb Infrared Photodiodes On Alternative Substrates And Inp/ingaas Quantum Well Infrared Photodetectors: Pixel And Focal Plane Array Performance

Ozer, Selcuk 01 June 2005 (has links) (PDF)
InAsxSb1-x (Indium Arsenide Antimonide) is an important low bandgap semiconductor whose high quality growth on GaAs or Si substrates is indispensible for low cost, large format infrared focal plane arrays (FPAs). Quantum well infrared photodetector (QWIP) technology, relying on mature semiconductors, is also promising for the above purpose. While AlGaAs/GaAs has been the standard material system for QWIPs, the search for alternative materials is needed for better performance. This thesis reports a detailed investigation of molecular beam epitaxy grown mid-wavelength infrared InAsxSb1-x photodiodes on alternative substrates, and long wavelength infrared InP/InGaAs QWIPs. In the first part of the study, InSb and InAs0.8Sb0.2 photodiodes grown on Si and GaAs substrates are investigated to reveal the performance degrading mechanisms due to large lattice mismatch. InAs0.8Sb0.2/GaAs photodiodes yield peak detectivities of 1.4&times / 1010 and 7.5&times / 108 cmHz&frac12 / /W at 77 K and 240 K, respectively, showing that the alloy is promising for both cooled and near room temperature detectors. Under moderate reverse bias, 80 K RoA product limiting mechanism is trap assisted tunneling, which introduces considerable 1/f noise. InSb/Si photodiodes display peak 77 K detectivity as high as ~1&times / 1010 cmHz 1/2/W and reasonably high peak quantum efficiency in spite of large lattice mismatch. RoA product of detectors at 80 K is limited by Ohmic leakage with small activation energy (25 meV). Bias and temperature dependence of 1/f noise is in reasonable agreement with Kleinpenning&rsquo / s mobility fluctuation model, confirming the validity of this approach. The second part of the study concentrates on InP/In0.53Ga0.47As QWIPs, and 640&times / 512 FPA, which to our knowledge, is the largest format InP/InGaAs QWIP FPA reported. InP/InGaAs QWIPs yield quantum efficiency-gain product as high as 0.46 under moderate bias. At 70 K, detector performance is background limited with f/2 aperture up to ~3 V bias where peak responsivity (2.9 A/W) is thirty times higher than that of the Al0.275Ga0.725As/GaAs QWIP with similar spectral response. Impact ionization in InP/InGaAs QWIPs does not start until the average electric-field reaches 25 kV/cm, maintaining high detectivity under moderate bias. The 640&times / 512 InP/InGaAs QWIP FPA yields noise equivalent temperature difference of ~40 mK at an FPA temperature as high as 77 K and reasonably low NETD even with short integration times (t). 70 K NETD values of the FPA with f/1.5 optics are 36 and 64 mK under &ndash / 0.5 V (t=11 ms) and &ndash / 2 V (t=650 Rs) bias, respectively. The results clearly show the potential of InP/InGaAs QWIPs for thermal imaging applications requiring short integration times. Keywords: Cooled infrared detectors, InAsSb, QWIP, focal plane array.
15

Long Wavelength Mercury Cadmium Telluride Photodiodes And Focal Plane Arrays

Asici, Burak 01 September 2005 (has links) (PDF)
This thesis reports the fabrication and characterization of long wavelength infrared mercury cadmium telluride (Hg1-xCdxTe) photodiodes and 128x128 focal plane arrays grown on lattice matched cadmium zinc telluride (Cd1-yZnyTe) substrates by metal organic vapor phase epitaxy (MOVPE). The dark current modeling of 33x33 mm2 Hg1-xCdxTe photodiodes has shown the dark current is dominated by trap assisted tunneling under small reverse bias voltages typically used to bias these detectors. The dominant dark current mechanisms under high reverse bias and low forward bias are band&ndash / to&ndash / band tunneling and generation&ndash / recombination, respectively. The photodiodes have yielded a peak 77 K detectivity of 3.2x1010 cm&amp / #8730 / Hz/W with a cut-off wavelength (50%) of 10.92 mm. It has also been found that the 1/f noise current of the detectors at 1 Hz is related to the trap-assisted tunneling current through the empirical relation in=&amp / #945 / TAT(ITAT)&amp / #946 / with &amp / #945 / TAT=7.0 x 10-5 and &amp / #946 / =0.65. In the course of the focal plane array (FPA) fabrication process development work, ohmic contact formation on p-type Hg1-xCdxTe and mesa wet etch were studied in detail. Contacts with chromium, gold, platinum and copper on p-type Hg1-xCdxTe resulted in bad ohmic contacts, which did not seem to improve with annealing. On the other hand a HgTe cap layer on p-type Hg1-xCdxTe resulted in good ohmic contact with acceptably low resistance. Among the etchants studied for mesa etching of the diode structures, Br2/HBr solution yielded the best performance. After developing all of the steps of FPA processing, 128x128 Hg1-xCdxTe FPAs were successfully fabricated and tested in a thermal imager. While thermal imaging was performed with the FPAs, high nonuniformity of the material and low R0A product of the pixels did not allow high sensitivity imaging.
16

Osmotaxis in Escherichia coli

Rosko, Jerko January 2017 (has links)
Bacterial motility, and in particular repulsion or attraction towards specific chemicals, has been a subject of investigation for over 100 years, resulting in detailed understanding of bacterial chemotaxis and the corresponding sensory network in many bacterial species including Escherichia coli. E. Coli swims by rotating a bundle of flagellar filaments, each powered by an individual rotary motor located in the cell membrane. When all motors rotate counter-clockwise (CCW), a stable bundle forms and propels the cell forward. When one or more motors switch to clock-wise (CW) rotation, their respective filaments fall out of the bundle, leading to the cell changing orientation. Upon switching back to CCW, the bundle reforms and propels the cell in a new direction. Chemotaxis is performed by the bacterium through prolonging runs by suppressing CW rotation when moving towards nutrients and facilitating reorientation by increasing CW bias when close to a source of a harmful substance. Chemicals are sensed through interaction with membrane bound chemosensors. These proteins can interact with a very specific set of chemicals and the concentrations they are able to sense are in the range between 10-⁶ and 10-² M. However, experiments have shown that the osmotic pressure exerted by large (> 10-¹ M) concentrations of solutes, which have no specificity for binding to chemosensors (e.g. sucrose), is able to send a signal down the chemotactic network. Additionally, clearing of bacterial density away from sources of high osmolarity has been previously observed in experiments with agar plates. This behaviour has been termed osmotaxis. The aim of this doctoral thesis work is to understand how different environmental cues influence the tactic response and ultimately, combine at the network output to direct bacterial swimming. As tactic responses to chemical stimuli have been extensively studied, I focus purely on the response to non-specific osmotic stimuli, using sucrose to elevate osmolarity. I monitor the chemotactic network output, the rotation of a single bacterial flagellar motor, using Back Focal Plane Interferometry over a variety of osmotic conditions. Additionally, in collaboration with Vincent Martinez, I studied the effect of elevated osmolality on swimming speed of large (104) bacterial populations, using differential dynamic microscopy (DDM). I have found that sudden increases in media osmolarity lead to changes of both motor speed and motor clockwise bias, which is the fraction of time it spends rotating clockwise. Changes in CW Bias proceed in two phases. Initially, after elevating the osmolarity, CW Bias drops to zero, indicating that the motor is exclusively in the ‘cell run’ mode. This phase lasts from 2-5 minutes depending on the magnitude of the change in solute concentration. What follows then is a distinct second phase where the CW Bias is elevated with respect to the initial levels and this phase lasts longer than 15-20 minutes. In comparison, for defined chemical stimuli, the motor output resets after several seconds, a behaviour termed perfect adaptation. For changes of 100 mOsm/kg and 200 mOsm/kg in magnitude the motors speed up, often by as much as a factor of two, before experiencing a gradual slow down. Despite the slow down, motors still rotate faster 15-20 minutes after the change in osmolarity, than they did before. For changes of 400 mOsm/Kg in magnitude the motors decrease sharply in speed, coming to a near halt, recovering after 5 minutes and eventually, on average, speeding up. DDM studies of free swimming bacteria have shown that elevated osmolality leads to higher swimming speeds, in agreement with single motor data. Using theoretical models of bacterial swimming from the literature, it is discussed how this motor output, although different to what is expected for chemotaxis, is able to drive bacteria away from regions of space with high osmolalities. Additionally, I have started extending the work done with sucrose, to another solute often used to elevate osmolality, sodium chloride. While sucrose is outer membrane impermeable, NaCl can cross the outer membrane into the periplasmic space. Another layer of complexity is that NaCl has some specificty for the chemoreceptors. The preliminary results are shown and qualitatively agree with those obtain with sucrose.
17

Design, fabrication, and testing of stellar coronagraphs for exoplanet imaging

Knight, Justin M., Brewer, John, Hamilton, Ryan, Guyon, Olivier, Milster, Thomas D., Ward, Karen 12 September 2017 (has links)
Complex-mask coronagraphs destructively interfere unwanted starlight with itself to enable direct imaging of exoplanets. This is accomplished using a focal plane mask (FPM); a FPM can be a simple occulter mask, or in the case of a complex-mask, is a multi-zoned device designed to phase-shift starlight over multiple wavelengths to create a deep achromatic null in the stellar point spread function. Creating these masks requires microfabrication techniques, yet many such methods remain largely unexplored in this context. We explore methods of fabrication of complex FPMs for a Phased-Induced Amplitude Apodization Complex-Mask Coronagraph (PIAACMC). Previous FPM fabrication efforts for PIAACMC have concentrated on mask manufacturability while modeling science yield, as well as assessing broadband wavelength operation. Moreover current fabrication efforts are concentrated on assessing coronagraph performance given a single approach. We present FPMs fabricated using several process paths, including deep reactive ion etching and focused ion beam etching using a silicon substrate. The characteristic size of the mask features is 5 mu m with depths ranging over 1 mu m. The masks are characterized for manufacturing quality using an optical interferometer and a scanning electron microscope. Initial testing is performed at the Subaru Extreme Adaptive Optics testbed, providing a baseline for future experiments to determine and improve coronagraph performance within fabrication tolerances.
18

Silicon-Based Infrared Photodetectors for Low-Cost Imaging Applications

Duran, Joshua 30 May 2019 (has links)
No description available.
19

SiGe Millimeter-Wave (W-Band) Down-Converter for Phased Focal Plane Array

Nagavalli Yogeesh, Maruthi 01 January 2013 (has links) (PDF)
A millimeter-wave (W-Band) down-converter for Phased Focal Plane Arrays (PFPAs) has been designed and fabricated using the IBM Silicon-Germanium (SiGe) BiCMOS 8HP process technology. The radio frequency (RF) input range of the down-converter chip is from 70 95GHz. The intermediate frequency (IF) range is from 5 30GHz. The local oscillator (LO) frequency is fixed at 65GHz. The down-converter chip has been designed to achieve a conversion gain greater than 20dB, a noise figure (NF) below 10dB and input return loss greater than 10dB. The chip also has novel LO circuitry facilitating LO feed-through among down-converters chips in parallel. This wide bandwidth down-converter will be part of millimeter-wave PFPA receiver designed and fabricated in collaboration with the University of Massachusetts-Amherst Department of Astronomy. This PFPA receiver will be installed on Green Bank Telescope (GMT) / Large millimeter wave telescope (LMT) in Q2 of 2014. This project is collaboration between the University of Massachusetts-Amherst (UMass), Brigham Young University (BYU) and National Radio Astronomy Observatory (NRAO). To the best of the author’s knowledge, this is first wide bandwidth down-converter at W-band to achieve this high gain and low noise figure among Si/SiGe based systems.
20

A Prototype Platform for Array Feed Development

Nagel, James Richard 20 October 2006 (has links) (PDF)
Radio frequency interference (RFI) is a growing problem for radio astronomers. One potential solution utilizes spatial filtering by placing an array of electrically small antennas at the focal plane of a parabolic reflector. This thesis documents the design and characterization of a prototype array feed and RF receiver that were used to demonstrate the spatial filtering principle. The array consists of a 7-element hexagonal arrangement of thickened dipole antennas tuned to a center frequency of 1600 MHz. The receiver is a two-stage, low-noise frequency mixer that is tunable over the entire L-band. This thesis also documents a new receiver design that is part of an upgrade to the outdoor antenna test range for the National Radio Astronomy Observatory in Green Bank, West Virginia. The array feed was demonstrated on a three-meter parabolic reflector by recovering a weak signal of interest that was obscured by a strong, broadband interferer. Similar results were also obtained when the interferer moved with an angular velocity of 0.1 degree per second, but only when the power in the interferer dominated the signal. The aperture efficiency was measured at 64%, but adaptive beamformers can slightly perturb this value through distortions in the beam pattern. This phenomenon, called pattern rumble, effectively reduced the sensitivity of the radio telescope, and was measured by comparing the SNRs of adaptive beamformers to the SNR of a fixed-weight beamformer. It was found that pattern rumble can reduce the useful integration time by roughly one order of magnitude. It was also found that mechanical instability of the primary reflector introduces a great deal of pattern rumble, even when the interferer is fixed in direction.

Page generated in 0.0732 seconds