• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 1
  • 1
  • Tagged with
  • 27
  • 9
  • 8
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Desenvolvimento de um equipamento para ensaio de fadiga de contato esfera sobre plano e sua aplicação na caracterização de ferros fundidos com matrizes de elevada dureza. / Development of a rolling contact fatigue test rig and its use for characterization of cast irons with high hardness matrix.

Julio Cesar Klein das Neves 28 September 2006 (has links)
Esse trabalho descreve o projeto e construção de um equipamento destinado ao estudo de fadiga de contato de rolamento e sua posterior aplicação na caracterização de ferros fundidos. O trabalho foi iniciado com a utilização de um equipamento previamente existente no Laboratório de Fenômenos de Superfície da EPUSP, a máquina I. Esse equipamento era baseado na substituição das pistas externas de um rolamento axial de esferas por corpos de prova na forma de arruelas. Ensaios preliminares mostraram que a máquina I apresentava limitações, a principal delas era não ser capaz de reproduzir integralmente o movimento de rolamento, havendo uma relação desconhecida rolamento/deslizamento no decorrer do ensaio. Com base nas dificuldades operacionais da máquina I, uma segunda máquina, também baseada em um rolamento axial, foi projetada e construída. Ensaios preliminares mostraram que o novo equipamento reproduzia mecanismos de falha por fadiga de contato de rolamento. A etapa seguinte então foi utilizar a máquina II no estudo de fadiga de contato de rolamento de dois tipos de ferro fundido com matrizes de levada dureza, um cinzento e um nodular, os quais foram testados em duas condições: com e sem pré-tensionamento e analisados segundo a estatística de Weibull. Um aço também foi ensaiado como referência. A pré-tensão foi aplicada com uma ferramenta bi-partida e modelada por elementos finitos. Foram realizados ensaios lubrificados, com a aplicação de uma pressão máxima de contato de 3,6 GPa e conduzidos até a falha dos materiais por lascamento da superfície de rolamento. Em todas as condições de ensaio o ferro fundido nodular se mostrou muito superior ao ferro cinzento. Enquanto esse último que apresentou resultados similares na condição com e sem pré-tensão, o ferro fundido nodular teve a sua curva de distribuição de falhas significativamente alterada pela aplicação de tensão externa. Uma heterogeneidade na distribuição do tamanho de nódulos de grafita fez com que as falhas ocorressem sempre na mesma região do corpo-deprova evidenciando a sensibilidade do ensaio a variáveis microestruturais. / This work presents design and construction of an equipment for rolling contact fatigue studying and its use to cast irons analysis. Firstly it was used an equipment available at Surface Phenomena Laboratory, in São Paulo University, which was called machine I. The design of the system followed the well-known architecture where races of a thrust ball bearing are substituted by washers made with the material under investigation. Preliminary tests have shown that the first machine had severe limitations, but the most important was lack of ability to reproduce rolling contact fatigue mechanisms. An unknown sliding/rolling ratio always took place in its work. Then a second machine was designed and assembled. Sets up tests have shown typical mechanisms of rolling contact fatigue. The next step was to use the new machine to study two types of cast irons, a gray iron and a ductile iron, under two test conditions: with and without pre-stress. Also a steel specimen was tested as a reference. Results were subjected to Weibull analysis. A device was developed for pre-stress application, and the specimen/device system was modeled by finite elements analysis. Tests were carried out till failure, under lubrication, and with maximum contact pressure of 3.6 GPa. Ductile cast iron behavior was superior to gray iron in all tests. Gray iron specimens with and without pre-stress presented very similar results. On the other hand, ductile iron probability failure curve was strongly affected by pre-stress. An unexpected heterogeneity on graphite nodules size distribution promoted failures on just one region, which is an evidence of test sensitivity to micro structural changes.
22

Concentrating solar power technologies using molten salts for storage and production of energy

Cardozo, Franclim Rodrigues January 2012 (has links)
Estágio realizado na Fundació CTM Centre Tecnològic, e orientado por Jose Luis Romeral Martínez / Tese de Mestrado Integrado. Engenharia do Ambiente. Faculdade de Engenharia. Universidade do Porto. 2012
23

Avaliação das propriedades físicas dos ferros fundidos pelos métodos de ensaios não destrutivos: ultrassom e frequência de ressonância / Evaluation of physical properties of cast iron by non-destructive testing: ultrasound and resonant frequency

Martins, Laura Pires Ribeiro 27 July 2015 (has links)
Made available in DSpace on 2016-12-08T17:19:26Z (GMT). No. of bitstreams: 1 Laura Martins.pdf: 7177519 bytes, checksum: b45e0db2f27a3c198d3ed77145efa51c (MD5) Previous issue date: 2015-07-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In the production of automotive parts and components, nondestructive testing is of great importance for the estimation of physical and mechanical properties such as the detection of defects. This study aims the evaluation of two non-destructive tests (ultrasound and resonance frequency) by determining the elastic modulus and damping capacity in samples with different graphite morphology and also in thin wall sections of engine blocks. These techniques were also used to identify the presence of solidification microporosity. It was found that these methods allow estimating values of elastic modulus very accurately, better to that obtained with tensile test. Also the correlation between microstructure and mechanical and physical properties are better with ultrasonic and resonance frequency than with tensile test. Those tests also enable to characterize the influence of microporosities on the elastic behavior, as well as the response and sensitivity of damping capacity with the increase of interfaces in the microstructure. the resonant frequency test provide better results when compared with ultrasound, mainly for the characterization of the microstructure, the presence of defects and determination of modulus of elasticity and damping at specimens with regular geometry, since the results resonant test is affected by the total microstructure of the sample, not only by local microstructure, as in the ultrasonic testing. The study of the thin sections in cylinder blocks enabled to correlate microstructures with the thickness of the sections for both materials (gray and compacted graphite iron) and the modulus of elasticity. It also showed the influence of the graphite (morphology and nodularization) on the damping.. Due to geometric limits, the ultrasound test stood out to be more effective in the local measurement of modulus of elasticity for these samples. Thus, for the conditions of microstructure characterization, evaluation of properties and identification and determination of defects, ultrasound set to be more effective technique for scientific studies (samples with regular geometry) and direct application in the industry (thin sections of engine blocks ). / Para a produção de peças e componentes automobilísticos, a utilização de ensaios não destrutivos é de grande importância, tanto para a estimativa de propriedades físicas e mecânicas como na detecção de defeitos. Este estudo tem por objetivo avaliar dois métodos de ensaios não destrutivos (ultrassom e frequência de ressonância) através da determinação do módulo de elasticidade e do amortecimento de vibrações para amostras com variação de morfologia da grafita e seções de parede fina dos blocos de motor. Essas técnicas também foram empregadas para identificar a presença de microporosidades de contração na solidificação. Verificou-se que essas metodologias permitem estimar valores de módulo de elasticidade com bastante precisão, superior à obtida com ensaios de tração e estabelecem melhores correlações entre as microestruturas e as propriedades mecânico-físicas. Esses ensaios, ainda, possibilitam caracterizar a influência dos microrechupes sobre o comportamento elástico, bem como a resposta e sensibilidade da capacidade de amortecimento com o aumento de interfaces na microestrutura do material. Através dessas avaliações observou-se uma maior eficácia do ensaio de frequência de ressonância quando comparado com o ultrassom, pois através desse pode-se obter melhores resultados para a caracterização das condições da microestrutura, da presença de defeitos e na determinação do módulo de elasticidade e amortecimento em corpos de prova de geometria regular. O estudo das seções finas possibilitou correlacionar as microestruturas com as espessuras das seções para ambos os materiais (ferro fundido cinzento e vermicular). Ainda possibilitou verificar a influência da grafita (morfologia e grau de nodularização) sobre o amortecimento. Para essas análises, verificaram-se as condições e dificuldades dos ensaios não destrutivos quanto à geometria e acabamento dos corpos de prova e fatores ligados à microestrutura. Durante esse estudo, o ensaio de ultrassom destacou-se por ser mais eficaz na medição local do módulo de elasticidade para essas amostras. Assim, para as condições de caracterização de microestrutura, avaliação das propriedades, e identificação e determinação de defeitos, o ultrassom configura ser a técnica mais eficaz para estudos científicos (amostras com geometria regular) e aplicação direta na indústria (seções finas dos blocos de motor).
24

Aparências metalográficas e corrosão seletiva de fases de aços inoxidáveis fundidos austenítico e martensítico atacados potenciostaticamente / Metallographic appearances and selective corrosion of phases of austenitic and martensitic cast stainless steels potentiostatically etched

Souza, Solange de 01 October 1997 (has links)
A corrosão seletiva de fases de dois tipos de aços inoxidáveis fundidos foi analisada, ao serem submetidos a vários valores constantes de potencial, a partir da região catódica para a anódica da curva de polarização. Os aços estudados foram: austenítico (ACI CF-3M) solubilizado e martensítico (ACI CA-6NM) normalizado e revenido. As curvas de polarização foram traçadas potenciodinamicamente, a uma velocidade de varredura de 0,16 m.V.s-1 em solução aerada contendo H2SO4 1M e NaCl 1M, pH 0,35, à temperatura ambiente. Vários valores de potencial foram selecionados, previamente localizados nas regiões catódica, ativa, passiva e transpassiva da curva de polarização. Potenciostaticamente, foram atingidos os valores de potencial selecionados, sendo eles mantidos fixos por 1800 s. Após o ataque potenciostático, as aparências metalográficas dos aços foram verificadas, desde a região catódica até a anódica. Por microssonda eletrônica, foram quantificados os elementos químicos presentes nas fases dos aços. Para melhor avaliar o início de propagação de pite, foi determinada a porcentagem de íons liberados para o eletrólito, após a imposição de valores de potencial críticos de pite predeterminados pelas curvas de polarização, pelas aparências metalográficas e pelas curvas de densidade de corrente em função do tempo. / The selective corrosion of phases present in two types of cast stainless steels was analyzed, when submitled to several constant values of potential, starting from the cathodic to the anodic regions of the polarization curve. The cast stainless steels were: austenitic (ACI CF-3M) solubilized and martensitic (ACI CA-6NM) normalized and tempered. The polarization curves were obtained at a scanning rate of 0.16 mV.s-1 in 1M H2S04 and 1M NaCI solution, pH 0.35 and at room temperature. Several potential values were selected, previously located in the cathodic, active, passive and transpassive regions of the polarization curve. The values of the selected potential were maintained fixed for 1800 s. After the potentiostatic etching, the metallographic appearances of the steels were verified, from the cathodic to the anodic region. Through electronic microprobe analysis, the present chemical elements were quantified in the phases of the steels. For betler evaluating the beginning of pitling propagation in the studied steels, liberated ion percentage for the solution was determined, after the imposition of critic pitting potential values predetermined from the polarization curves, through the metallographic appearances obtained after potentiostatic etching of the samples and the current density curves as a function of time.
25

Analise termica na solidificação de ferros fundidos cinzentos hipoeuteticos / Thermal analysis on solidification of hypoeutectic gray cast iron

Silva, Jorge Ayrton da 13 February 2007 (has links)
Orientador: Amauri Garcia / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-08T17:48:12Z (GMT). No. of bitstreams: 1 Silva_JorgeAyrtonda_M.pdf: 5941604 bytes, checksum: 9ec8b76ce4cbb57c06994f1a8307f767 (MD5) Previous issue date: 2007 / A análise térmica é amplamente utilizada como método de controle de processos metalúrgicos e na investigação da composição química de ferros fundidos na prática de fundição. Um meio confiável de avaliação da composição de ferros fundidos é disponibilizado pela técnica do Carbono Equivalente, que é baseada na mudança de inclinação da curva de resfriamento na temperatura liquidus durante o resfriamento de uma amostra de ferro fundido a partir do estado líquido. O presente trabalho é focado no desenvolvimento de um novo sensor para análise térmica, um sensor de imersão, que objetiva contribuir com determinações mais confiáveis de composição durante as operações de fundição. Foram desenvolvidos experimentos em diferentes empresas de fundição, utilizando-se tanto o sensor de imersão quanto o tradicional sensor tipo cápsula, normalmente utilizado na prática de fundição. As comparações de composições químicas, medidas por essas duas técnicas e medidas fornecidas por análise de espectrometria de emissão óptica, demonstram que geralmente o sensor de imersão fornece resultados mais confiáveis. Uma análise térmica realizada durante o resfriamento de ferro fundido em um dispositivo unidirecional com uma coquilha, e utilizando um conjunto de termopares, permitiu também a determinação quantitativa de variáveis térmicas de solidificação, tais como: coeficientes transitórios de transferência de calor metal/molde e molde/ambiente e taxa de resfriamento à frente da isoterma liquidus / Abstract: Thermal analysis is a widely used method for metallurgical process control and investigation of alloy composition of cast irons in foundry practice. A reliable means of rapidly evaluating the composition of cast irons is available by the Carbon-Equivalent technique, which is based on the change in thermal arrest temperature of the liquidus as the sample of molten cast iron freezes. The present work focuses on the development of a new sensor for thermal analysis, a dip-sensor, wich aims to contribute to more reliable determination of alloy composition during casting operation. Experiments were carried-out in different foundries by using both the dipsensor and the traditional capsule-sensor, which is normally used in foundry practice. The comparison of alloy compositions measured by these two techniques with analysis performed by Arc/Spark spectrometry has shown that generally the dip-sensor provides more reliable results. Thermal analysis conducted during cooling of molten cast iron in a unidirectional chill apparatus, by using a set of thermocouples, has also permitted the quantitative determination of solidification thermal variables, such as: transient metal/mold and mold/ambient heat transfer coefficients and tip cooling rates / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
26

Aparências metalográficas e corrosão seletiva de fases de aços inoxidáveis fundidos austenítico e martensítico atacados potenciostaticamente / Metallographic appearances and selective corrosion of phases of austenitic and martensitic cast stainless steels potentiostatically etched

Solange de Souza 01 October 1997 (has links)
A corrosão seletiva de fases de dois tipos de aços inoxidáveis fundidos foi analisada, ao serem submetidos a vários valores constantes de potencial, a partir da região catódica para a anódica da curva de polarização. Os aços estudados foram: austenítico (ACI CF-3M) solubilizado e martensítico (ACI CA-6NM) normalizado e revenido. As curvas de polarização foram traçadas potenciodinamicamente, a uma velocidade de varredura de 0,16 m.V.s-1 em solução aerada contendo H2SO4 1M e NaCl 1M, pH 0,35, à temperatura ambiente. Vários valores de potencial foram selecionados, previamente localizados nas regiões catódica, ativa, passiva e transpassiva da curva de polarização. Potenciostaticamente, foram atingidos os valores de potencial selecionados, sendo eles mantidos fixos por 1800 s. Após o ataque potenciostático, as aparências metalográficas dos aços foram verificadas, desde a região catódica até a anódica. Por microssonda eletrônica, foram quantificados os elementos químicos presentes nas fases dos aços. Para melhor avaliar o início de propagação de pite, foi determinada a porcentagem de íons liberados para o eletrólito, após a imposição de valores de potencial críticos de pite predeterminados pelas curvas de polarização, pelas aparências metalográficas e pelas curvas de densidade de corrente em função do tempo. / The selective corrosion of phases present in two types of cast stainless steels was analyzed, when submitled to several constant values of potential, starting from the cathodic to the anodic regions of the polarization curve. The cast stainless steels were: austenitic (ACI CF-3M) solubilized and martensitic (ACI CA-6NM) normalized and tempered. The polarization curves were obtained at a scanning rate of 0.16 mV.s-1 in 1M H2S04 and 1M NaCI solution, pH 0.35 and at room temperature. Several potential values were selected, previously located in the cathodic, active, passive and transpassive regions of the polarization curve. The values of the selected potential were maintained fixed for 1800 s. After the potentiostatic etching, the metallographic appearances of the steels were verified, from the cathodic to the anodic region. Through electronic microprobe analysis, the present chemical elements were quantified in the phases of the steels. For betler evaluating the beginning of pitling propagation in the studied steels, liberated ion percentage for the solution was determined, after the imposition of critic pitting potential values predetermined from the polarization curves, through the metallographic appearances obtained after potentiostatic etching of the samples and the current density curves as a function of time.
27

Estudio y diseño de materiales de impresión 3d que soporten los sistemas de esterilización médicos

Fuentes Fuentes, Jorge Mauricio 11 February 2022 (has links)
[ES] Actualmente se usan varios materiales poliméricos para aplicaciones médicas. Debido a la facilidad de poder fabricar formas complejas, que con otros métodos es difícil realizarlas, se usa cada vez con más frecuencia la manufactura aditiva (MA) con materiales poliméricos. El proceso de fabricación aditiva por extrusión de material (MEX), es el proceso de MA más utilizado debido al bajo coste de los equipos, la facilidad de acceso a los materiales (filamento de impresión 3D) y la relativamente baja complejidad de la técnica con respecto a otras tecnologías de procesamiento de polímeros. Estos materiales deben ser compatibles con el cuerpo humano y se requiere que las partes impresas en 3D sean resistentes a los procesos de esterilización, para evitar cualquier tipo de infección o contaminación. Los procesos de esterilización por calor húmedo (MH) y calor seco (DH) son los más usados en el campo de la medicina y son asequibles incluso en instalaciones de baja complejidad. Sin embargo, varios de estos materiales poliméricos, disminuyen sus propiedades mecánicas, térmicas y reológicas y/o cambian dimensionalmente al ser sometidos a los procesos de esterilización. Algunos materiales poliméricos biocompatibles usados para aplicaciones médicas que se encuentran disponibles a nivel comercial en forma de filamento 3D para MA, como el poli(ácido láctico) (PLA), presentan alta resistencia mecánica y rigidez. Sin embargo, su fragilidad impide su uso extendido y esta fragilidad puede ser incluso mayor después de someter a los materiales a procesos de esterilización. Para investigar los efectos de estos dos métodos de esterilización, se imprimieron por MEX algunos especímenes de ensayo con filamentos comerciales de baja temperatura de fusión como el polietileno tereftalato glicol reforzado con fibra de carbono (PETG-CF), poli (ácido láctico) (PLA), CPE , PLA Smartfill®, y un material compuesto elaborado a partir de PLA y reforzado con hidroxiapatita (PLA-HA). Asimismo, se imprimieron por MEX materiales comerciales de alto punto de fusión como el policarbonato (PC), nylon (PA) y polipropileno (PP). Para caracterizar los materiales antes y después de los procesos de esterilización se realizaron pruebas mecánicas, térmicas, termo-mecánicas y ópticas para determinar el efecto de los procesos de impresión sobre cada tipo de material y verificar si las propiedades finales cumplen los requisitos para aplicaciones médicas. Se utilizó la espectroscopia infrarroja por transformada de Fourier (FTIR) para identificar los cambios químicos en los grupos funcionales de las muestras impresas y esterilizadas. Luego, se realizó un estudio morfológico por estereomicroscopio y microscopio electrónico de barrido (SEM) para estudiar los cambios de las muestras debido a los procesos de esterilización. Finalmente, en el caso del polipropileno se hizo la descripción del modelo reológico usando el modelo de Cross-WLF para inferir en las condiciones de procesamiento por MA. En general se encontró que los materiales como el nylon (PA), el polipropileno (PP) y el policarbonato (PC) pueden soportar los procesos de esterilización por calor, por lo que podrían emplearse para el desarrollo de materiales para prótesis y/u otras prestaciones médicas. Por su parte, el PETG reforzado con fibra de carbono, el CPE, el PLA, el PLA Smartfill® y el PLA reforzado con hidroxiapatita (PLA-HA) varían dimensionalmente después de los procesos de esterilización, afectando las propiedades mecánicas de las partes impresas. Por lo tanto, no se recomiendan para su aplicación en prótesis esterilizadas mediante los dos procesos de esterilización estudiados. Sin embargo, el PLA Smartfill® que es más fácil de procesar que los otros PLAs estudiados (PLA y PLA-HA) y que presenta menor contracción durante los procesos de esterilización, podría ser utilizado para aplicaciones que no permanecerán en el cuerpo humano y que requieren menores prestaciones mecánicas, como por ejemplo en guías de cirugía / [CA] Actualment s'usen diversos materials polimèrics per a aplicacions mèdiques,. A causa de la facilitat de poder fabricar formes complexes, que amb altres mètodes és difícil realitzar-les, s'usa cada vegada amb més freqüència la manufactura additiva (MA) amb materials polimèrics acceptats per a aplicacions mèdiques. El procés de fabricació additiva per extrusió de material (MEX), és el procés de MA més utilitzat a causa de el baix cost dels equips, la facilitat d'accés als materials (filament d'impressió 3D) i la relativament baixa complexitat de la tècnica respecte a altres tecnologies de processament de polímers com l'extrusió, emmotllament per injecció, etc. Aquests materials han de ser compatibles amb el cos humà i es requereix que les parts impreses en 3D siguin resistents als processos d'esterilització, per evitar qualsevol tipus d'infecció o contaminació, la qual cosa s'aconsegueix mitjançant el procés d'esterilització. Els processos d'esterilització per calor humida (MH) i calor seca (DH) són els més usats en el camp de la medicina i són assequibles fins i tot en instal·lacions de baixa complexitat (exemple: dispensaris, consultoris, etc.). No obstant això, diversos d'aquests materials polimèrics, disminueixen les seves propietats mecàniques, tèrmiques i reològiques i / o canvien dimensionalment a l'ésser sotmesos als processos d'esterilització. Alguns materials polimèrics biocompatibles usats per a aplicacions mèdiques que es troben disponible a nivell comercial en forma de filament 3D per MA, com el àcid polilàctic (PLA), presenten alta resistència mecànica i rigidesa. No obstant això, la seva fragilitat impedeix el seu ús estès i aquesta fragilitat pot ser fins i tot major després de sotmetre els materials a processos d'esterilització. Per a investigar els efectes d'estos dos mètodes d'esterilització, es van imprimir per MEX alguns espècimens d'assaig amb filaments comercials de baixa temperatura de fusió com el polietilé tereftalato glicol reforçat amb fibra de carboni (PETG-CF) , poli (àcid làctic) (PLA) , CPE , PLA Smartfill®, i un material compost elaborat a partir de PLA i reforçat amb hidroxiapatita (PLA-HA) . Així mateix, es van imprimir per MEX materials comercials d'alt punt de fusió com el policarbonat (PC) , niló (PA) i polipropileno (PP) . Per a caracteritzar els materials abans i després dels processos d'esterilització es van realitzar proves mecàniques, tèrmiques, termomecàniques i òptiques per a determinar l'efecte dels processos d'impressió sobre cada tipus de material i verificar si les propietats finals complixen els requisits per a aplicacions mèdiques. Es va utilitzar l'espectroscòpia infraroja per transformada de Fourier (FTIR) per a identificar els canvis químics en els grups funcionals de les mostres impreses i esterilitzades. Després, es va realitzar un estudi morfològic per estereomicroscopio i microscopi electrònic d'agranat (SEM) per a estudiar els canvis de les mostres degut als processos d'esterilització. Finalment, en el cas del polipropileno es va fer la descripció del model reológico usant el model de Cross-WLF per a inferir en les condicions de processament per MA. En general es va trobar que els materials com el niló (PA) , el polipropilens (PP) i el policarbonat (PC) poden suportar els processos d'esterilització per calor, per la qual cosa podrien emprar-se per al desenrotllament de materials per a pròtesi y/u altres prestacions mèdiques. Per la seua banda, el PETG reforçat amb fibra de carboni, el CPE, el PLA, el PLA Smartfill® i el PLA reforçat amb hidroxiapatita (PLA-HA) varien dimensionalment després dels processos d'esterilització, afectant les propietats mecàniques de les parts impreses. Per tant, no es recomanen per a la seua aplicació en pròtesi esterilitzades per mitjà dels dos processos d'esterilització estudiats. No obstant això, el PLA Smartfill® que és més fàcil de processar que els altres PLAs estudiats (PLA i PLA-HA) i que presenta menor contracció durant els process / [EN] Various polymeric materials are currently used for medical applications. Due to the ease of being able to manufacture complex shapes, which with other methods is difficult to perform, additive manufacturing (MA) with polymeric materials is increasingly used. The additive manufacturing process by material extrusion (MEX), is the most widely used MA process due to the low cost of the equipment, the ease of access to the materials (3D printing filament) and the relatively low complexity of the technique with respect to other polymer processing technologies. These materials must be compatible with the human body and require that the 3D printed parts be resistant to sterilization processes, to avoid any type of infection or contamination. Wet heat (MH) and dry heat (DH) sterilization processes are the most widely used in the medical field and are affordable even in low-complexity facilities. However, these polymeric materials decrease their mechanical, thermal and rheological properties and/or change dimensionally when subjected to sterilization processes. Some biocompatible polymeric materials used for medical applications that are commercially available in 3D filament form for MA, such as poly(lactic acid) (PLA), have high mechanical strength and rigidity. However, their fragility prevents their widespread use, and this fragility can be even greater after subjecting the materials to sterilization processes. To investigate the effects of these two sterilization methods, some test specimens with commercial low-temperature melting filaments such as carbon fiber reinforced polyethylene terephthalate glycol (PETG-CF), poly (lactic acid) (PLA), CPE, Smartfill PLA®, and a material were printed by MEX. compound made from PLA and reinforced with hydroxyapatite (PLA-HA). Commercial high melting point materials such as polycarbonate (PC), nylon (PA) and polypropylene (PP) were also printed by MEX. To characterize the materials before and after the sterilization processes, they performed mechanical, thermal, thermo-mechanical and optical tests to determine the effect of the printing processes on each type of material and verify if the final properties meet the requirements for medical applications. Fourier transform infrared spectroscopy (FTIR) was used to identify chemical changes in the functional groups of printed and sterilized samples. Then, a morphological study was performed by stereomicroscope and scanning electron microscope (SEM) to study the changes of the samples due to sterilization processes. Finally, in the case of polypropylene, the description of the rheological model was made using the Cross-WLF model to infer in the processing conditions by MA. In general, it was found that materials such as nylon (PA),polypropylene (PP) and polycarbonate (PC) can withstand heat sterilization processes, so they could be used for the development of materials for prostheses and / or other medical benefits. Carbon fiber reinforced PETG, CPE, PLA, Smartfill PLA® and hydroxyapatite-reinforced PLA (PLA-HA) varied dimensionally after sterilization processes, affecting the mechanical properties of the printed parts. Therefore, they are not recommended for application in sterilized prostheses by the two sterilization processes studied. However, Smartfill PLA® which is easier to process than the other PLAs studied (PLA and PLA-HA) and which has less contraction during sterilization processes, could be used for applications that will not remain in the human body and that require lower mechanical performance, such as in surgery guides. In this way, the MA by MEX represents a simple and economical technique that can be implemented for the development of materials for custom-designed surgery guides and sterilizable by simple processes such as wet heat and dry heat, available in low complexity medical facilities. / Fuentes Fuentes, JM. (2022). Estudio y diseño de materiales de impresión 3d que soporten los sistemas de esterilización médicos [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/180857 / TESIS

Page generated in 0.0309 seconds