51 |
人工股関節置換術後女性の運動機能に対する荷重位エクササイズの効果 / Effect of weight-bearing exercise on motor function in female after total hip arthroplasty塚越, 累 23 May 2016 (has links)
京都大学 / 0048 / 新制・論文博士 / 博士(人間健康科学) / 乙第13033号 / 論人健博第2号 / 新制||人健||3(附属図書館) / 32991 / 京都大学大学院医学研究科人間健康科学系専攻 / (主査)教授 坪山 直生, 教授 黒木 裕士, 教授 妻木 範行 / 学位規則第4条第2項該当 / Doctor of Human Health Sciences / Kyoto University / DFAM
|
52 |
THE SURFACE AND SUBSURFACE CHARACTERIZATION OF RETRIEVED METAL-ON-POLYETHYLENE HIP PROSTHESES USING ELECTRON MICROSCOPYVuong, Vicky 06 1900 (has links)
First devised over half a century ago, metal-on-polyethylene (MoP) hip prostheses have become the gold standard for total hip arthroplasty (THA), a surgical intervention for degenerative hip joint conditions. The accumulation of polyethylene wear debris after long-term, in vivo articulations, can induce adverse cellular reactions, osteolysis and aseptic loosening of the implant – ultimately resulting in the failure of the THA. Despite the distinct differences between the biotribology of MoP and MoM prostheses, there is a lack of congruent high resolution research investigating the biotribological interactions and surface structures of MoP hip prosthesis components. This study characterized the surface and subsurface microstructural changes in failed MoP hip prosthesis retrievals using advanced electron microscopy techniques. The samples were comprised of retrieved metallic cobalt-chromium-molybdenum (CoCrMo) alloy femoral head components, one ultra-high molecular weight polyethylene (UHMWPE) acetabular cup component, and unused CoCrMo reference samples. The surface of the reference samples contained linear, parallel, uniform scratches as a result of the manufacturing process; whereas the surface of the retrieval samples were covered in an abundance of scratches and a layer of residual deposits, attributable to in vivo articulation of the implant. Characteristic hard phases were observed and examined on the surface and from the cross-sectional preparation of the cast CoCrMo samples. The multiphasic hard phases on the cast samples can strengthen the material but also be sites of crack propagation and material detachment, contributing to the generation of wear particles. Lastly, a nanocrystalline layer, 20 to 400 nm in thickness was observed in the subsurface microstructure of all samples (including references). Previous MoM studies suggest that the nanocrystalline layer is a result of dynamic crystallization in response to multidirectional, chronic loading in vivo, however, the presence of the layer in the unimplanted references suggest that the nanocrystalline layer can be formed during the production of the prosthesis component and therefore, pre-exists implantation. The imperfections on new, unused implants can have protective effects (e.g. troughs from scratches can be a reservoir for wear debris) but may influence in vivo wear processes after implantation (e.g. scratches may be a source of wear debris). Higher resolution analyses on more retrieval and reference samples are required to pinpoint the exact mechanism of failure in MoP hip prostheses and extend the longevity and efficacy of THA. / Thesis / Master of Applied Science (MASc)
|
53 |
Patient-Specific Instruments for Total Hip ArthroplastyStegman, Jacob J. 07 September 2017 (has links)
No description available.
|
54 |
New techniques for characterization of surface and volumetric wear in total hip athroplastyKohm, Andrew Christopher 23 April 2004 (has links)
No description available.
|
55 |
Évaluation biomécanique de la locomotion à la suite d'une arthroplastie de la hancheBouffard, Vicky 04 1900 (has links)
Depuis les dernières années, la prévalence de personnes souffrant de dégénérescence des cartilages articulaires, communément appelée ostéoarthrite (OA), ne cesse d’augmenter. Les douleurs articulaires et les raideurs musculaires associées à cette pathologie mènent à des limitations des capacités fonctionnelles, à une perte de mobilité et d’autonomie affectant grandement la qualité de vie de ces personnes. Afin de soulager les personnes souffrant de cette pathologie, l’arthroplastie de la hanche est une procédure chirurgicale fréquemment utilisée. À la suite de cette chirurgie, une amélioration de la qualité de vie et une reprise des capacités fonctionnelles sont souvent observées. Cependant, comparativement à des sujets sains, la vitesse de marche est diminuée, une faiblesse des muscles abducteurs de la hanche est constatée et des mouvements compensatoires au niveau du tronc sont persistants. L’objectif de cette thèse est d’évaluer le patron locomoteur chez des patients qui subiront une arthroplastie de la hanche. Plus spécifiquement, les adaptations locomotrices pré et post-opératoires seront quantifiées dans le but d’apporter des modifications aux programmes de réhabilitation pour ainsi favoriser un patron locomoteur sans déficit.
Afin de répondre à cet objectif, trois études distinctes ont été effectuées. Dans le cadre de la première étude, l’impact de l’implantation d’une prothèse totale de la hanche avec une tête fémorale de large diamètre et une prothèse de resurfaçage a été évalué par rapport aux sujets sains lors de la locomotion. Au cours de cette étude, le contrôle du tronc a été analysé en utilisant la distance entre le centre de masse corporel et le centre articulaire de la hanche opérée. Suite aux résultats obtenus, aucune différence majeure n’existe entre les deux types de prothèses en ce qui a trait au contrôle du tronc et ce, à un an post-opératoire.
Lors de la deuxième étude, la symétrie des paramètres biomécaniques des membres inférieurs lors de la locomotion chez des patients ayant bénéficié de l’implantation d’une prothèse de la hanche a été caractérisée suite à un programme d’exercices péri-opératoires (pré et post-opératoire). Lors de cette étude, le programme d’exercices péri-opératoires était complémentaire au protocole de réadaptation du centre hospitalier. D’après les résultats obtenus lors de cette étude exploratoire, ce programme d’exercices péri-opératoires semble permettre d’améliorer la symétrie de la puissance et du travail musculaire au niveau de la hanche, du genou et de la cheville favorisant ainsi un patron de marche avec de minimes compensations.
Finalement, dans le cadre de la troisième étude, l’approche prédictive et l’approche fonctionnelle, utilisées pour localiser le centre articulaire de la hanche, ont été comparées aux mesures radiographiques, chez des patients à la suite d’un remplacement articulaire de la hanche. À la suite de cette étude, les résultats démontrent que l’utilisation de l’approche fonctionnelle est plus appropriée chez des patients ayant bénéficié d’une arthroplastie de la hanche. En effet, cette approche individualisée est plus précise ce qui, par conséquent, permettra d’obtenir des résultats de plus grande qualité lors d’analyses biomécaniques de la locomotion. / In recent years, the prevalence of people suffering from joint cartilage degeneration, called osteoarthritis (OA), still increases. The joint pain and muscle stiffness related to this pathology have an impact on patients’ quality of life by limiting their functional capacities, mobility and autonomy. In order to relieve these patients, hip arthroplasty is a frequently used surgical procedure. Even if there is an improvement in quality of life and a restoration of functional capacities in these patients, some impairment seem to persist during the post-operative period. The walking velocity is slower when compared to healthy subjects, a hip abductor muscle weakness is observed and trunk compensations lasted during the post-operative period. The aim of this thesis is to evaluate patients undergoing hip arthroplasty during locomotion. More specifically, gait pattern adaptations will be quantified pre and post-operatively to revise rehabilitation programs in order to promote a healthy gait pattern.
Three separate studies were conducted to meet this objective. The first study compared the effect of a large femoral head hip prosthesis and a hip resurfacing prosthesis to healthy subjects. During this study, the trunk control was analyzed using the distance between the body center of mass and the hip prosthetic joint center. The results obtained show no major difference between the two types of prosthesis and the healthy control one year post-operatively.
During the second study, biomechanics parameter symmetry of the lower limb of gait pattern in patients undergoing hip arthroplasty was characterized following a peri-operative (pre and post-operatively) exercise program. The exercise program was complementary to the medical center standard rehabilitation program. Based on the results of this exploratory study, the peri-operative exercise program seems to improve the symmetry of the muscular power and work of the hip, knee and ankle which promote a healthy gait pattern without compensations.
Finally, for the third study, the predictive and the functional approaches, used to locate the hip joint center, were compared to radiographic measurements in patients undergoing hip arthroplasty. The results of this study demonstrated that the functional approach was more appropriate for these patients. This individualized approach is more accurate which leads to quality improvement during biomechanical analysis of gait pattern.
|
56 |
Évaluation biomécanique de la locomotion à la suite d'une arthroplastie de la hancheBouffard, Vicky 04 1900 (has links)
Depuis les dernières années, la prévalence de personnes souffrant de dégénérescence des cartilages articulaires, communément appelée ostéoarthrite (OA), ne cesse d’augmenter. Les douleurs articulaires et les raideurs musculaires associées à cette pathologie mènent à des limitations des capacités fonctionnelles, à une perte de mobilité et d’autonomie affectant grandement la qualité de vie de ces personnes. Afin de soulager les personnes souffrant de cette pathologie, l’arthroplastie de la hanche est une procédure chirurgicale fréquemment utilisée. À la suite de cette chirurgie, une amélioration de la qualité de vie et une reprise des capacités fonctionnelles sont souvent observées. Cependant, comparativement à des sujets sains, la vitesse de marche est diminuée, une faiblesse des muscles abducteurs de la hanche est constatée et des mouvements compensatoires au niveau du tronc sont persistants. L’objectif de cette thèse est d’évaluer le patron locomoteur chez des patients qui subiront une arthroplastie de la hanche. Plus spécifiquement, les adaptations locomotrices pré et post-opératoires seront quantifiées dans le but d’apporter des modifications aux programmes de réhabilitation pour ainsi favoriser un patron locomoteur sans déficit.
Afin de répondre à cet objectif, trois études distinctes ont été effectuées. Dans le cadre de la première étude, l’impact de l’implantation d’une prothèse totale de la hanche avec une tête fémorale de large diamètre et une prothèse de resurfaçage a été évalué par rapport aux sujets sains lors de la locomotion. Au cours de cette étude, le contrôle du tronc a été analysé en utilisant la distance entre le centre de masse corporel et le centre articulaire de la hanche opérée. Suite aux résultats obtenus, aucune différence majeure n’existe entre les deux types de prothèses en ce qui a trait au contrôle du tronc et ce, à un an post-opératoire.
Lors de la deuxième étude, la symétrie des paramètres biomécaniques des membres inférieurs lors de la locomotion chez des patients ayant bénéficié de l’implantation d’une prothèse de la hanche a été caractérisée suite à un programme d’exercices péri-opératoires (pré et post-opératoire). Lors de cette étude, le programme d’exercices péri-opératoires était complémentaire au protocole de réadaptation du centre hospitalier. D’après les résultats obtenus lors de cette étude exploratoire, ce programme d’exercices péri-opératoires semble permettre d’améliorer la symétrie de la puissance et du travail musculaire au niveau de la hanche, du genou et de la cheville favorisant ainsi un patron de marche avec de minimes compensations.
Finalement, dans le cadre de la troisième étude, l’approche prédictive et l’approche fonctionnelle, utilisées pour localiser le centre articulaire de la hanche, ont été comparées aux mesures radiographiques, chez des patients à la suite d’un remplacement articulaire de la hanche. À la suite de cette étude, les résultats démontrent que l’utilisation de l’approche fonctionnelle est plus appropriée chez des patients ayant bénéficié d’une arthroplastie de la hanche. En effet, cette approche individualisée est plus précise ce qui, par conséquent, permettra d’obtenir des résultats de plus grande qualité lors d’analyses biomécaniques de la locomotion. / In recent years, the prevalence of people suffering from joint cartilage degeneration, called osteoarthritis (OA), still increases. The joint pain and muscle stiffness related to this pathology have an impact on patients’ quality of life by limiting their functional capacities, mobility and autonomy. In order to relieve these patients, hip arthroplasty is a frequently used surgical procedure. Even if there is an improvement in quality of life and a restoration of functional capacities in these patients, some impairment seem to persist during the post-operative period. The walking velocity is slower when compared to healthy subjects, a hip abductor muscle weakness is observed and trunk compensations lasted during the post-operative period. The aim of this thesis is to evaluate patients undergoing hip arthroplasty during locomotion. More specifically, gait pattern adaptations will be quantified pre and post-operatively to revise rehabilitation programs in order to promote a healthy gait pattern.
Three separate studies were conducted to meet this objective. The first study compared the effect of a large femoral head hip prosthesis and a hip resurfacing prosthesis to healthy subjects. During this study, the trunk control was analyzed using the distance between the body center of mass and the hip prosthetic joint center. The results obtained show no major difference between the two types of prosthesis and the healthy control one year post-operatively.
During the second study, biomechanics parameter symmetry of the lower limb of gait pattern in patients undergoing hip arthroplasty was characterized following a peri-operative (pre and post-operatively) exercise program. The exercise program was complementary to the medical center standard rehabilitation program. Based on the results of this exploratory study, the peri-operative exercise program seems to improve the symmetry of the muscular power and work of the hip, knee and ankle which promote a healthy gait pattern without compensations.
Finally, for the third study, the predictive and the functional approaches, used to locate the hip joint center, were compared to radiographic measurements in patients undergoing hip arthroplasty. The results of this study demonstrated that the functional approach was more appropriate for these patients. This individualized approach is more accurate which leads to quality improvement during biomechanical analysis of gait pattern.
|
57 |
Leg length discrepancy and femoral offset after total hip arthroplasty : clinical and radiological studiesMahmood, Sarwar January 2016 (has links)
Every year, about 1 million patients worldwide and 16000 patients in Sweden undergo total hip arthroplasty (THA). This surgical intervention is considered a successful, safe and cost-effective procedure to regain pain-free mobility and restore hip joint function in patients suffering from severe hip joint disease or trauma. Besides relieving the pain, restoration of biomechanical forces around the hip with appropriate femoral offset (FO), leg length and proper component position and orientation are important goals. The radiographic preoperative planning and postoperative evaluation of these parameters require good validity, interobserver reliability and intraobserver reproducibility. It remains controversial as to how much postoperative leg length discrepancy (LLD) and FO change are acceptable. Generally, lengthening of the operated leg ≥ 10mm and FO reduction of the operated hip > 5mm should be avoided by using preoperative radiological templating and intraoperative measurement methods. There is no consensus on the association between LLD and FO and outcome after THA. The aims of this thesis were to: 1. To determine the influence of non-corrected LLD after THA on patients’ reported hip function and quality of life (QoL). 2. To study the association of global FO changes after THA with patients’ reported hip function, QoL and abductor muscle strength. 3. To evaluate the concurrent validity of the Sundsvall method of measuring postoperative global FO by comparing it to a standard method and to evaluate the interobserver reliability and intraobserver reproducibility of measurement of postoperative global FO, LLD and acetabular cup inclination and anteversion. 4. To analyse the postoperative radiographs of THA patients with leg lengthening and FO reduction to determine whether the problem is located in the stem, cup or both. Study I: A prospective cohort study of 174 patients with unilateral osteoarthritis (OA), comparing patients with lengthening ≥ 10mm, restoration (between 9 mm lengthening and 5 mm shortening) or shortening > 5 mm of the operated leg after THA. Follow up was 12–15 months. We found that a LLD of up to 20 mm did not influence the functional outcome (WOMAC) or QoL (EQ-5D). However, the lengthening group showed less improvement in WOMAC and more use of a shoe lift. Study II: A prospective cohort study of 222 patients with unilateral hip OA, comparing patients with decreased global FO (> 5 mm reduction), restored FO (within 5 mm restoration), and increased FO (> 5 mm increment) after THA. Follow up was was 12–15 months. The unadjusted results showed that the decreased FO group had a worse WOMAC index, less abductor muscle strength, and more use of walking aids. When these results were adjusted for possible confounding factors, only global FO reduction was statistically significantly associated with reduced abductor muscle strength. The incidence of residual hip pain and analgesics use was similar in the 3 groups. Study III: A prospective cohort study of 90 patients with primary unilateral OA treated with THA. Global FO using the Sundsvall method, global FO (standard method), LLD, acetabular cup inclination and anteversion were measured on postoperative radiographs. The interobserver reliability and intraobserver reproducibility were tested using three independent observers. We found that the Sundsvall method is as reliable as the standard method and the evaluated radiographic measurement methods have the required validity and reliability to be used in clinical practice. Study IV: A prospective cohort study of 174 patients with unilateral primary OA treated with THA. LLD and global FO were measured on postoperative radiographs. Patients with lengthening of the operated leg ≥ 10mm (n=41) and patients with reduction of global FO > 5mm (n=58) were further studied to investigate the amount of lengthening and global FO reduction that took place in the stem and in the cup compared with the contralateral side. The interobserver reliability and intraobserver reproducibility were tested using two independent observers. We found that post-THA lengthening of the operated leg ≥ 10mm was mainly caused by improper placement of the femoral stem, whereas a decrease of global FO > 5 was caused by improper placement of both acetabular and femoral components. The radiological measurement methods used showed substantial to excellent interobserver reliability and intraobserver reproducibility and are therefore clinically useful. The main conclusions of this thesis are: LLD up to 20 mm and reduced global FO more than 5 mm did not influence the functional outcome or quality of life at 12–15 months postoperatively. Lengthening ≥ 10mm was associated with increased use of a shoe lift. A reduction of global FO more than 5 mm compared to the contralateral hip was associated with weaker hip abductor muscles and more use of walking aids. Therefore both should be avoided. The radiographic measurement methods of LLD, global FO, cup inclination and anteversion have the required validity and reliability to be used in clinical practice. Lengthening of the operated leg is mainly caused by improper femoral stem positioning while global FO reduction results from improper positioning of both acetabular and femoral components. Surgeons should be aware of these operative pitfalls in order to minimize component malpositioning. / Varje år opereras ungefär 1 miljon patienter runt om i världen och 16000 patienter i Sverige med en total höftledsprotes (THA). Operation med höftledsprotes anses vara enav de mest framgångsrika, säkra och kostnadseffektiva kirurgiska åtgärderna med syfte att för att återställa livskvalité. Målet är att smärtlindra och återställa rörligheten i dendestruerade höftleden vid artros, reumatisk destruktion eller men efter exempelvis Perthes sjukdom. Vid operation med THA är det viktigt att återställa de biomekaniskakrafterna runt höftleden med en adekvat så kallad femoral offset (FO), postoperativ benlängdsskillnad (BLS) och ett tillfredsställande komponentläge. Den preoperativaplaneringen och den postoperativa bedömning av dessa parametrar kräver god tillförlitlighet, det vill säga validitet och reproducerbarhet både mellan olika bedömareoch vid upprepade mätningar av samma bedömare. Det är fortfarande inte klarlagt hur mycket postoperativ förändring i FO och BLS som är acceptabla. I dagsläget är detacceptabelt om den postoperativa benförlängningen understiger 1 cm och förändringen i FO är under 5 mm. Det finns ingen konsensus huruvida det föreligger ett sambandmellan BLS, FO och den patientrapporterade höftfunktionen och livskvalitén efter THA. Syftet med denna avhandling var: 1. Att studera effekten av icke-korrigerad BLS efter THA på den patientrapporterade höftfunktionen och livskvalitén. 2. Att studera effekten av förändringen i FO efter THA på den patientrapporterade höftfunktion, livskvalitén och muskelstyrka i abduktion. 3. Att utvärdera validitet och reliabilitet av en så kallad global FO genom att jämföra den med den gällande standard metoden samt studera tillförlitlighet av de radiologiskamätningar av postoperativa BLS, FO, cup inklination och anteversion efter THA. 4. Att radiologiskt undersöka i vilken av komponenterna (stam eller cup) somförändringen i FO och BLS verkar vara förlagd. Studie I: En prospektiv kohortstudie med 174 patienter som behandlats med THA för en primär unilateral koxartros. Patienterna delades in i tre grupper; de som fått en BLSförlängning över 10mm, återställning (mellan 9mm förlängning och 5mm förkortning) eller förkortning >5mm av det opererande benet efter THA. Uppföljning gjordes 12-15månader postoperativt. Vi fann att BLS upp till 20mm påverkade inte höftfunktion (WOMAC) och livskvalité (EQ-5D), men den förlängda gruppen visade en mindreförbättring i WOMAC och rapporterade en mer frekvent användning av skoinlägg. Studie II: En prospektiv kohortstudie med 222 patienter som behandlats med THA för en primär unilateral koxartros. Patienterna delades in i tre grupper; de patienter medförminskad FO (> 5mm minskning), återställd FO (inom 5mm) eller ökad FO (>5mm ökning). Uppföljning genomfördes efter 1 år med WOMAC, styrkemätning av höftensabduktorer och en frågeformulär. En minskad FO var associerade med en minskad styrka i höftens abduktorer. Det var ingen skillnad mellan grupperna gällandekvarstående höftsmärta och användning av analgetika. Studie III: En prospektiv kohortstudie med 90 patienter som behandlats med THA på grund av primär unilateral koxartros. På de postoperativa röntgenbilderna uppmättesglobala FO (Sundsvalls metodologi), globala FO (standard metod), BLS, cup inklination och anteversion. Reliabilitet och reproducerbarhet bedömdes mellan treoberoende observatörer. Vi fann att global FO (enligt Sundsvalls metodologi) är lika tillförlitlig som den nuvarande standardmetoden och de utvärderade radiologiskamätmetoderna har hög validitet och reliabilitet och kan således användas i klinisk praxis. Studie IV: En prospektiv kohortstudie med 174 patienter som behandlats med en THA för en primär unilateral koxartros. På de postoperativa röntgenbilderna uppmättes BLSoch globala FO. Patienter med förlängning ≥ 10mm (n=41) och patienter med minskning av globala FO >5mm (n=58) studerades for att mäta förlängning ochglobala FO minskning som sitter i stammen eller i cup jämfört med kontralaterala sidan. Reliabilitet och reproducerbarhet bedömdes av två oberoende observatörer. Vifann att en BLS över 10mm sitter framför allt i stamkomponenten i lårbenet medan en minskning i FO över 5 mm sitter i båda stam och cup. De radiologiska mätmetodernahar hög reliabilitet och reproducerbarhet och kan således användas i klinisk praxis. De viktigaste slutsatserna i denna avhandling är: 1. BLS med en förlängning upp till 20 mm och en minskning av globala FO mer än 5 mm påverkar inte patientrapporterad höftfunktion eller livskvalitet 1 år postoperativt. 2. BLS med en förlängning mer än 9 mm var associerad med mer användning av skoinlägg. En minskad FO med mer än 5 mm jämfört med den icke opererade höftenvar associerad med en sämre muskelstyrka i abduktion och ökat användning av gånghjälpmedel. 3. De radiologiska mätmetoderna av BLS, FO, acetabulära komponentens inklination och anteversion har hög validitet och reliabilitet, vilket kan användas i klinisk praxis. 4. En förlängning av det opererade benet orsakas främst av en positioneringen av stamkomponenten i lårbenet medan förlust av FO beror på otillfredsställande placeringav både stam och den acetabulära komponenten. Kirurger bör vara medveten om dessa operativa fallgropar för att optimera det kirurgiska resultatet.
|
58 |
Early Mortality After Total Hip Arthroplasty In SwedenGarland, Anne January 2017 (has links)
Every year 16 000 individuals receive a total hip arthroplasty (THA) in Sweden. Even though THA is a common procedure, adverse events do occur. The most dramatic complication is death in the postoperative phase. The overall aim of this thesis was to describe and investigate early mortality after THA in Sweden. Sweden has an ideal platform for national observational registry studies, thanks to the use of personal identity numbers. Operation-specific information was collected from the Swedish Hip Arthroplasty Register, medical information from the National Board of Health and Welfare, and socioeconomic information was collected from Statistics Sweden. Main outcome was 90-day mortality. Study I was a prospective observational register study investigating the risk of mortality after a simultaneous bilateral THA compared with staged bilateral THA. There was no clinically relevant difference in early postoperative mortality between the two groups. Studies II and III were nation-wide matched cohort studies, with adjustment for comorbidity and socioeconomic background. Adjusted early mortality in femoral neck fracture patients receiving a THA is about double compared with a matched control population. Young (60-69 years) femoral neck fracture patients receiving a THA have a low absolute mortality risk, while those who are older than 80 years with a higher degree of medical comorbidity run a high risk of early death (II). In study III healthier, younger patients with higher socioeconomic status tended to be selected for cementless THA, resulting in selection bias. Even after accounting for this bias, however, there remains a small absolute and adjusted increase in the risk of death within 14 days after elective THA surgery using fully cemented implants. Study IV was a nationwide prospective cohort study comparing different comorbidity measures in terms of predicting early postoperative mortality after THA. A less data-demanding comorbidity measure is better at predicting 90-day mortality than more commonly used coding algorithms. In conclusion, socioeconomic background and the presence of comorbidities have an important influence on early mortality after THA, while the type of fixation is of less importance. Future mortality studies could benefit from the use of data that are routinely collected, and thus avoid the logistically complicated procedure now necessary to merge national databases.
|
59 |
Vibroacustografia na avaliação tridimensional de artroplastia total de quadril / Vibro-acoustography in the tridimensional evaluation of total hip arthroplastyKamimura, Hermes Arytto Salles 29 April 2011 (has links)
A vibroacustografia (VA) é uma técnica de imagem de alta resolução lateral (<0,7 mm), livre de speckles, não invasiva e que utiliza radiação não-ionizante, baseada no fenômeno de combinação não-linear de ondas de ultrassom (MHz) que gera uma região focal estreita de baixa frequência (kHz). Neste trabalho, propõe-se uma avaliação tridimensional baseada em imagens de VA da área descoberta de implantes, após o procedimento cirúrgico de artroplastia total de quadril (ATQ). A ATQ é uma técnica terapêutica de substituição de articulações do quadril por implantes, em pacientes com osteoartrose avançada. Atualmente, o acompanhamento pós-operatório é auxiliado pela análise de radiografia plana por raios-X. Contudo, esta técnica apresenta limitações na avaliação da estabilidade dos implantes, tais como: avaliação imprecisa da área, uma vez que, a radiografia plana trata o problema tridimensional como bidimensional; impossibilidade de visualização de algumas regiões do implante, devido ao sobreposicionamento das regiões numa imagem planar; restrição do uso de radiação ionizante na região da pelve em pacientes jovens. Devido à alta atenuação da onda de ultrassom incidindo sobre objetos densos, a VA pode ser ajustada para adquirir imagens relativas, principalmente, à superfície destes. Uma correção da topologia baseada na geometria do implante é apresentada, a fim de se avaliar com precisão a área superficial na representação tridimensional da imagem de VA. A correção da topologia baseada em aquisições em modo-B também é apresentada, sendo útil na avaliação da forma de ossos ou nos casos em que a forma do objeto estudado é desconhecida. Além disso, é apresentado um estudo numérico da utilização de transdutores matriciais reconfiguráveis (RCA, do inglês reconfigurable array) para a formação de feixe em VA. Um estudo paramétrico da seleção de abertura, número de canais, número de elementos, distância focal e parâmetros de varredura eletrônica do feixe é apresentado para demonstrar a viabilidade e avaliar o desempenho da imagem de VA utilizando o RCA. A função de espalhamento de ponto do sistema foi calculada com base em métodos de espectro angular usando a aproximação de Fresnel para fontes retangulares. Foram discutidas as vantagens de transdutores bidimensionais e RCA, e aspectos relacionados à importância clínica da implementação do RCA na VA, tais como resolução espacial, taxa de aquisição da imagem e implementação do RCA em máquinas comerciais. Conclui-se que: a aquisição de imagens por VA foi menos sensível ao ângulo de incidência das ondas de ultrassom do que por modo-B e apresentou alta resolução e alto contraste entre o osso e o implante, o que permitiu uma avaliação precisa da área exposta do implante; os transdutores RCA podem aprimorar a aquisição de imagens por VA, devido à sua resolução espacial similar à de transdutores confocais e à possibilidade de deflexão eletrônica do feixe (em inglês steering) nos planos de elevação e azimutal. / Vibro-acoustography (VA) is a high lateral resolution (<0.7 mm), speckle-free, non- ionizing and non-invasive image based on the nonlinear combination phenomenon of ultrasound waves (MHz) that generates a narrow focus region of low frequency (kHz). In this work, we propose a VA-based tridimensional evaluation of the exposed area of implants, after total hip arthroplasty (THA). THA is a therapeutic surgery procedure in which the hip joints are replaced by metal prostheses in patients with advanced osteoarthritis. Currently, the postoperative assessment of THA is performed by analyzing planar X-ray radiographies. However, this technique presents limitations in the implant stability evaluation such as: inaccurate evaluation of the area, since the planar radiography reduces the tridimensional problem into a two-dimensional one; problems in the visualization of some regions of the implants due to the superimposition of the regions; limitations of using ionizing radiation in the pelvis region of young patients. Due to the high attenuation of the ultrasound wave into objects of high density, the VA image can be set to mainly acquire the surface information. Topological correction based on the geometry of the implant is presented in order to accurately evaluate the surface area in tridimensional representation of the VA image. The topological correction based on B-mode slices is also presented and is useful in the evaluation of bone shape or in cases which the shape of the object is unknown. Furthermore, it is presented a numerical study of the use of reconfigurable arrays (RCA) for VA beam formation. A parametric study of the aperture selection, number of channels, number of elements, focal distance and steering parameters is presented in order to show the feasibility and evaluate the performance of VA imaging based on RCA. The point-spread function of the system is calculated based on angular spectrum methods using the Fresnel approximation for rectangular sources. Advantages of two-dimensional and RCA arrays and aspects related to clinical importance of the RCA implementation in VA such as spatial resolution, image frame-rate, and commercial machine implementation are discussed. It is concluded that: the VA image is less sensitive to the wave incident angle than B-mode; the VA image presents high-resolution and high-contrast between bone and implant, which allowed an accurate evaluation of the uncovered area; RCA transducers improve the VA acquisition by producing spatial resolution similar to confocal transducers, and due to the possibility of steering in elevation and azimuthal planes.
|
60 |
"LIA eller morfin spinalt vid primär total höftplastik". : en långtidsuppföljning av effekter för postoperativ smärta och mobilisering.Lassas, Anna January 2009 (has links)
<p>Vid operation av primär total höftplastik finns det olika metoder för postoperativ smärtlindring. En tidigare genomförd studie på ett mellansvenskt sjukhus (nedan kallad ”höftprojektet”) visade att ”Local infiltration analgesia” (LIA) initialt minskade postoperativ smärta, underlättade mobilisering samt förkortade vårdtiden, jämfört med spinalt morfin. I denna studie genomfördes en långtidsuppföljning av höftprojektet med mätningar efter 6 respektive 12 veckor. Studiegruppen hade fått LIA vid operationsslutet och kontrollgruppen spinalt morfin. Båda grupperna hade en spinal bedövning under operationen. Denna långtidsuppföljning genomfördes med hjälp av journalgranskning och hade en deskriptiv och jämförande design med en kvantitativ ansats. Studiegruppen bestod av 40 patienter och kontrollgruppen 11 patienter. Studerade variabler var smärta mätt genom Visuell Analog Skala (VAS), behov av analgetika och mobilisering. Resultatet visade att det inte fanns någon signifikant skillnad mellan de båda grupperna när det gäller mobilisering under ett längre perspektiv. Det fanns dock en signifikant skillnad när det gäller smärta efter 3 månader, då studiegruppen uppgav en lägre grad av smärta än kontrollgruppen.</p> / <p>There are several methods for postoperative pain treatment after primary total hip replacement. It was shown in a earlier study at a Swedish hospital (below named as "the hip project") that "Local infiltration analgesia" (LIA) decreased pain, facilitated early postoperative mobility and earlier discharge from the hospital, compared with spinally administered morphine. Present study is a long term follow up of the hip project with two measures at 6 and 12 weeks. The study group was given LIA towards the end of the operation while the control group were given spinal morphine at the induction. Both groups had spinal analgesia during the surgery. The long term follow up was conducted by a comparative design and the data was collected from the patient’s charts and files. The variables were pain measured by Visual Analogous Scale (VAS), need of pain relieves and general mobility. The study group contained of 40 patients and the control group of 11. The result relived no significant differences between the two groups regarding long term mobility. There was, however, a significant difference in pain after 12 weeks; the study group had less pain that the control group.</p><p> </p><p> </p>
|