Conforto térmico e concentração de CO2 em salas de cirurgias e salas de espera para pacientes, climatizadas artificialmente. / Thermal comfort and CO2 concentration in air conditioned operating rooms and waiting rooms for patients.

Santana, Elaine Gonçalves Ferreira 19 April 2013 (has links)
Nos últimos anos tem havido um aumento no estudo da qualidade do ar interno relacionado aos sistemas de ventilação mecânica e condicionamento do ar. Isso é especialmente fundamental em hospitais, onde a transmissão da contaminação pelo ar é considerada uma das principais causas de aquisição de doenças por pacientes, profissionais de saúde e visitantes. Além disso, essas instituições por abrigarem diversos setores, cada um com uma especificidade e função, exigem diferentes condições de conforto ambiental, sob os aspectos higrotérmico e de qualidade do ar, além do acústico e luminoso. Com o objetivo de avaliar a qualidade o ar, sob os parâmetros de conforto térmico e da concentração de dióxido de carbono em ambientes hospitalares climatizados artificialmente, realizou-se uma investigação de campo em salas de espera e salas de cirurgias de uma amostra de seis edifícios hospitalares na cidade de São Paulo e região metropolitana. Para coleta dos dados foram utilizados instrumentos de monitoramento, portáteis e de elevada precisão, adequados para a realização da pesquisa. Os resultados obtidos a partir da análise desses dados apontaram relevantes problemas relacionados ao conforto e a qualidade do ar. Dentre esses problemas, destacam-se a ausência de controle do diferencial de pressão entre as salas de cirurgias e os corredores; a divergência entre as temperaturas operativas ideais para promoção do conforto térmico para grupos de pessoas com diferentes vestimentas e nível de atividade, ocupando um mesmo ambiente, no caso, as salas de cirurgias; a insuficiência de renovação de ar, especialmente nas salas de espera equipadas com o sistema de climatização do tipo split-system; além da ausência de padronização entre os critérios dos referenciais técnicos mais adotados. Sob esses aspectos, percebeu-se a necessidade de melhoria do conhecimento da interação entre os ocupantes e o ambiente, especialmente naqueles onde o controle se faz necessário para a promoção da saúde. / In recent years has been increased interest in thermal comfort and air quality of indoor environments related to mechanical ventilation systems and air conditioning. This is especially crucial in hospitals where contaminated air transmission is considered a major cause of acquiring disease for patients, health care professionals and visitors. Moreover, these institutions having different sectors, each one with a speciality and function, require different conditions of environmental comfort, in terms of hygrothermal, air quality, acoustic and luminous aspects. In order to evaluate the air quality under the parameters of thermal comfort and carbon dioxide concentration in air conditioning hospital environments, it was carried out a field investigation in waiting rooms and operating rooms in six hospitals in São Paulo and metropolitan region. For data collection were used portable monitoring devices, suitable for research. The results from data analysis indicated significant problems related to thermal comfort and indoor air quality. Among these problems, it can be highlighted the lack of the differential pressure control between the operating rooms and corridors; the divergence among the optimal operative temperatures to provide thermal comfort for different groups of people with different clothing and activity level, occupying the same environment, in this case, the operating rooms; the disregard with the air changes required, especially in waiting rooms equipped with the splitsystem; besides the lack of standardization among the technical references criteria often used. Under these aspects, it is necessary to improve the knowledge of the interaction between the occupants and the environment, especially where the environmental control is decisive to promote the health.
2

Desenvolvimento de indicador de convergência de tecnologias e procedimentos de saúde em prontuário digital de pacientes (ICOTECH). / Development of an indicator technology convergence and health procedures in patient digital health record (PDP).

Sá, Carlos 16 May 2016 (has links)
Esta dissertação de mestrado apresenta o desenvolvimento de umindicador para quantificar o nível de convergência de tecnologias e procedimentos relativos ao Prontuário Digital de Pacientes (PDP) em instituições de saúde. Apresenta um estudo evolutivo do tradicional prontuário em papel e o prontuário eletrônico de pacientes, considerando as tecnologias, a integração e interoperabilidade, com as modernas tecnologias digitais e de mobilidade. A abrangência de sua utilização extrapola o simples uso na área médica e hospitalar, contribuindo com todos os procedimentos e processos para o segmento de saúde. O trabalho desenvolve um conjunto de métricas considerando componentes como o perfil da instituição de saúde, fatores influenciadores da convergência, os ambientes de saúde aplicáveis, os vários procedimentos e processos de saúde e as funcionalidades de software. Estes cinco componentes do indicador denominado de ICOTECH Indicador de Convergência de Tecnologias e Procedimentos em Prontuário Digital de Pacientes constituem-se por 205 métricas analisadas com mais de 113 variáveis. Estas combinações são quantificadas por meio de algoritmo ICOTECH, comparando-se os valores médios do último período anual, o valor atual e o padrão de mercado conhecido. O resultado representa um indicador inédito ICOTECH calculado por métrica, componente e final permitindo aos tomadores de decisão o estabelecimento de metas a serem atingidas, além de análise de desempenho de competividade em relação aos padrões de mercado. / This dissertation presents the development of an indicator to quantify the level of convergence of technologies and procedures for Patient Digital Health Record (PDP) in health care settings. It presents an evolutionary study of traditional paper records and electronic medical records of patients, considering the technology, integration and interoperability with modern digital technologies and mobility. This work also provides subsidies to decision makers in the optimization of investments and analysis of medical procedures compared to industry standards. Its importance for public health policies, education, improvements in social welfare, scientific research, providing information and optimizing resources is analyzed to the fullest extent of the application of PDP. The scope of its use goes beyond the simple use in the medical and hospital sector, accounting for all procedures and processes for the healthcare segment. While increases its complexity provides more feedback information and data recorded in the PDP. In this sense, the paper develops a set of metrics considering components such as the profile of the health institution, the influencing factors convergence, healthcare environments applicable, the various procedures and health processes and software features. These five components of the indicator called ICOTECH Convergence indicator Technologies and Procedures in Patients Digital medical records are constituted by 205 metrics and analyzed more than 113 variables. These combinations are quantified through ICOTECH algorithm, comparing the average values of the last annual period, the current value and the standard of known market. The result represents a ICOTECH indicator calculated by meter, component and end allowing decision makers to establish goals to be achieved, and competitiveness analysis of performance in relation to industry standards.
3

Desenvolvimento de indicador de convergência de tecnologias e procedimentos de saúde em prontuário digital de pacientes (ICOTECH). / Development of an indicator technology convergence and health procedures in patient digital health record (PDP).

Carlos Sá 16 May 2016 (has links)
Esta dissertação de mestrado apresenta o desenvolvimento de umindicador para quantificar o nível de convergência de tecnologias e procedimentos relativos ao Prontuário Digital de Pacientes (PDP) em instituições de saúde. Apresenta um estudo evolutivo do tradicional prontuário em papel e o prontuário eletrônico de pacientes, considerando as tecnologias, a integração e interoperabilidade, com as modernas tecnologias digitais e de mobilidade. A abrangência de sua utilização extrapola o simples uso na área médica e hospitalar, contribuindo com todos os procedimentos e processos para o segmento de saúde. O trabalho desenvolve um conjunto de métricas considerando componentes como o perfil da instituição de saúde, fatores influenciadores da convergência, os ambientes de saúde aplicáveis, os vários procedimentos e processos de saúde e as funcionalidades de software. Estes cinco componentes do indicador denominado de ICOTECH Indicador de Convergência de Tecnologias e Procedimentos em Prontuário Digital de Pacientes constituem-se por 205 métricas analisadas com mais de 113 variáveis. Estas combinações são quantificadas por meio de algoritmo ICOTECH, comparando-se os valores médios do último período anual, o valor atual e o padrão de mercado conhecido. O resultado representa um indicador inédito ICOTECH calculado por métrica, componente e final permitindo aos tomadores de decisão o estabelecimento de metas a serem atingidas, além de análise de desempenho de competividade em relação aos padrões de mercado. / This dissertation presents the development of an indicator to quantify the level of convergence of technologies and procedures for Patient Digital Health Record (PDP) in health care settings. It presents an evolutionary study of traditional paper records and electronic medical records of patients, considering the technology, integration and interoperability with modern digital technologies and mobility. This work also provides subsidies to decision makers in the optimization of investments and analysis of medical procedures compared to industry standards. Its importance for public health policies, education, improvements in social welfare, scientific research, providing information and optimizing resources is analyzed to the fullest extent of the application of PDP. The scope of its use goes beyond the simple use in the medical and hospital sector, accounting for all procedures and processes for the healthcare segment. While increases its complexity provides more feedback information and data recorded in the PDP. In this sense, the paper develops a set of metrics considering components such as the profile of the health institution, the influencing factors convergence, healthcare environments applicable, the various procedures and health processes and software features. These five components of the indicator called ICOTECH Convergence indicator Technologies and Procedures in Patients Digital medical records are constituted by 205 metrics and analyzed more than 113 variables. These combinations are quantified through ICOTECH algorithm, comparing the average values of the last annual period, the current value and the standard of known market. The result represents a ICOTECH indicator calculated by meter, component and end allowing decision makers to establish goals to be achieved, and competitiveness analysis of performance in relation to industry standards.
4

Conforto térmico e concentração de CO2 em salas de cirurgias e salas de espera para pacientes, climatizadas artificialmente. / Thermal comfort and CO2 concentration in air conditioned operating rooms and waiting rooms for patients.

Elaine Gonçalves Ferreira Santana 19 April 2013 (has links)
Nos últimos anos tem havido um aumento no estudo da qualidade do ar interno relacionado aos sistemas de ventilação mecânica e condicionamento do ar. Isso é especialmente fundamental em hospitais, onde a transmissão da contaminação pelo ar é considerada uma das principais causas de aquisição de doenças por pacientes, profissionais de saúde e visitantes. Além disso, essas instituições por abrigarem diversos setores, cada um com uma especificidade e função, exigem diferentes condições de conforto ambiental, sob os aspectos higrotérmico e de qualidade do ar, além do acústico e luminoso. Com o objetivo de avaliar a qualidade o ar, sob os parâmetros de conforto térmico e da concentração de dióxido de carbono em ambientes hospitalares climatizados artificialmente, realizou-se uma investigação de campo em salas de espera e salas de cirurgias de uma amostra de seis edifícios hospitalares na cidade de São Paulo e região metropolitana. Para coleta dos dados foram utilizados instrumentos de monitoramento, portáteis e de elevada precisão, adequados para a realização da pesquisa. Os resultados obtidos a partir da análise desses dados apontaram relevantes problemas relacionados ao conforto e a qualidade do ar. Dentre esses problemas, destacam-se a ausência de controle do diferencial de pressão entre as salas de cirurgias e os corredores; a divergência entre as temperaturas operativas ideais para promoção do conforto térmico para grupos de pessoas com diferentes vestimentas e nível de atividade, ocupando um mesmo ambiente, no caso, as salas de cirurgias; a insuficiência de renovação de ar, especialmente nas salas de espera equipadas com o sistema de climatização do tipo split-system; além da ausência de padronização entre os critérios dos referenciais técnicos mais adotados. Sob esses aspectos, percebeu-se a necessidade de melhoria do conhecimento da interação entre os ocupantes e o ambiente, especialmente naqueles onde o controle se faz necessário para a promoção da saúde. / In recent years has been increased interest in thermal comfort and air quality of indoor environments related to mechanical ventilation systems and air conditioning. This is especially crucial in hospitals where contaminated air transmission is considered a major cause of acquiring disease for patients, health care professionals and visitors. Moreover, these institutions having different sectors, each one with a speciality and function, require different conditions of environmental comfort, in terms of hygrothermal, air quality, acoustic and luminous aspects. In order to evaluate the air quality under the parameters of thermal comfort and carbon dioxide concentration in air conditioning hospital environments, it was carried out a field investigation in waiting rooms and operating rooms in six hospitals in São Paulo and metropolitan region. For data collection were used portable monitoring devices, suitable for research. The results from data analysis indicated significant problems related to thermal comfort and indoor air quality. Among these problems, it can be highlighted the lack of the differential pressure control between the operating rooms and corridors; the divergence among the optimal operative temperatures to provide thermal comfort for different groups of people with different clothing and activity level, occupying the same environment, in this case, the operating rooms; the disregard with the air changes required, especially in waiting rooms equipped with the splitsystem; besides the lack of standardization among the technical references criteria often used. Under these aspects, it is necessary to improve the knowledge of the interaction between the occupants and the environment, especially where the environmental control is decisive to promote the health.
5

Interference Measurements and Throughput Analysis for 2.4 GHz Wireless Devices in Hospital Environments

Krishnamoorthy, Seshagiri 25 April 2003 (has links)
In recent years, advancements in the field of wireless communication have led to more innovative consumer products at reduced cost. Over the next 2 to 5 years, short-range wireless devices such as Bluetooth and Wireless Local Area Networks (WLANs) are expected to become widespread throughout hospital environments for various applications. Consequently the medical community views wireless applications as ineludible and necessary. However, currently there exist regulations on the use of wireless devices in hospitals, and with the ever increasing wireless personal applications, there will be more unconscious wireless devices entering and operating in hospitals. It is feared that these wireless devices may cause electromagnetic interference that could alter the operation of medical equipment and negatively impact patient care. Additionally, unintentional electromagnetic radiation from medical equipment may have a detrimental effect on the quality of service (QoS) of these short-range wireless devices. Unfortunately, little is known about the impact of these short-range wireless devices on medical equipment and in turn the interference caused to these wireless devices by the hospital environment. The objective of this research was to design and develop an automated software reconfigurable measurement system (PRISM) to characterize the electromagnetic environment (EME) in hospitals. The portable measurement system has the flexibility to characterize a wide range of non-contiguous frequency bands and can be monitored from a remote location via the internet. In this work electromagnetic interference (EMI) measurements in the 2.4 GHz ISM band were performed in two hospitals. These measurements are considered to be very first effort to analyze the 2.4 GHz ISM band in hospitals. Though the recorded EMI levels were well within the immunity level recommended by the FDA, it can be expected that Bluetooth devices will undergo a throughput reduction in the presence of major interferers such as WLANs and microwave ovens. A Bluetooth throughput simulator using semi-analytic results was developed as part of this work. PRISM and the Bluetooth simulator were used to predict the throughput for six Bluetooth Asynchronous Connectionless (ACL) transmissions as a function of piconet size and interferer distance. / Master of Science
6

Avaliação da qualidade do ar em ambientes hospitalares: ocorrência e diversidade do gênero Aspergillus / Air quality evaluation of hospital environments: occurrence and diversity of gender aspergillus

Ziehe, Érica Mendonça January 2014 (has links)
Submitted by Alexandre Sousa (alexandre.sousa@incqs.fiocruz.br) on 2015-06-19T19:00:16Z No. of bitstreams: 1 Dissertação_ERICA_ZIEHE.pdf: 76142458 bytes, checksum: 75499b175d6c2b0c7b2b0c87a82ec79b (MD5) / Approved for entry into archive by Alexandre Sousa (alexandre.sousa@incqs.fiocruz.br) on 2015-06-19T19:00:29Z (GMT) No. of bitstreams: 1 Dissertação_ERICA_ZIEHE.pdf: 76142458 bytes, checksum: 75499b175d6c2b0c7b2b0c87a82ec79b (MD5) / Approved for entry into archive by Alexandre Sousa (alexandre.sousa@incqs.fiocruz.br) on 2015-06-19T19:00:40Z (GMT) No. of bitstreams: 1 Dissertação_ERICA_ZIEHE.pdf: 76142458 bytes, checksum: 75499b175d6c2b0c7b2b0c87a82ec79b (MD5) / Made available in DSpace on 2015-06-19T19:00:40Z (GMT). No. of bitstreams: 1 Dissertação_ERICA_ZIEHE.pdf: 76142458 bytes, checksum: 75499b175d6c2b0c7b2b0c87a82ec79b (MD5) Previous issue date: 2014 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde. Programa de Pós-Graduação em Vigilância Sanitária / Fundação Oswaldo Cruz. Instituto Oswaldo Cruz. Laboratório de Taxonomia, Bioquímica e Bioprospecção de Fungos. Rio de Janeiro, RJ, Brasil. / A qualidade do ar em ambientes internos vem recebendo uma crescente atenção no Brasil na última década, e seus efeitos sobre a saúde humana têm sido objeto de intensivos estudos devido à grande diversidade de substâncias químicas, particulados e agentes biológicos encontrados nestes ambientes. Os contaminantes biológicos mais encontrados são principalmente fungos e bactérias. Nesse contexto, a ANVISA adotou os fungos como indicadores biológicos da qualidade do ar por meio da Resolução n° 9 de 16 de janeiro de 2003. O objetivo desse trabalho foi determinar a qualidade do ar de dois Hospitais Públicos. Avaliações quantitativas e qualitativas de contaminantes fungicos viáveis foram realizadas, para o controle e prevenção de riscos à saúde dos trabalhadores, pacientes e frequentadores destes ambientes. Além de isolar e identificar espécies do gênero Aspergillus para um levantamento das espécies mais frequentes no interior dos hospitais, também foram avaliadas a influência da temperatura e umidade relativa do ar nos níveis de contaminação. Foi proposta uma tabela de fator de risco em relação as espécies isoladas do gênero Aspergillus. As coletas das amostras de ar foram realizadas entre os anos de 2006 e 2007 e executadas de acordo com a Resolução n° 9 de 16 de janeiro de 2003 da ANVISA. As análises microbiológicas foram realizadas no Laboratório de Taxonomia, Bioquímica e Bioprospecção de Fungos do Instituto Oswaldo Cruz. Foram isolados um total de 2.978 fungos, onde 30% das amostras foram positivas para Aspergillus, dando um total de 360 cepas isoladas e identificadas a nível de espécie. As contagens variaram de 1375 UFC/m3 de ar a 7 UFC/m3 de ar, e as espécies do gênero Aspergillus mais encontradas foram A. flavus (24%), A. japonicus (16%), A. oryzae (15%), A. niger (15%), A. awamori (6%), A. fumigatus (4%). As maiores contagens foram registradas no outono e inverno e as menores foram na primavera e no verão, e as analises de correlação mostraram uma tendência da umidade relativa do ar influenciando os níveis de contaminação. Após todas as análises podemos concluir que se faz necessário o estabelecimento de normas fundamentadas em pesquisas, considerando as atividades e o tipo de usuário, buscando novos valores de VMR e indicando os microrganismos importantes como possíveis indicadores na má qualidades do ar de interiores. / The indoor air quality has received increasing attention in Brazil in the last decade, and its effects on human health have been the subject of intensive studies due to the wide variety of chemicals, particulates and biological agents found in these environments. Biological contaminants most commonly found are mainly fungi and bacteria. In this context, ANVISA adopted fungi as biological indicators of air quality through Resolution No. 9 of January 16, 2003. The aim of this study was to determine the air quality of the two Public Hospitals. Quantitative and qualitative evaluations of viable antifungal contaminants were performed for the control and prevention of health risks to workers, patients and patrons of these environments. In addition to isolating and identifying species of the genus Aspergillus to a survey of the most common species within hospitals, also the influence of temperature and relative humidity levels of contamination were evaluated. A table of risk factors regarding the isolated species of the genus Aspergillus was proposed. The collection of air samples were performed between the years 2006 and 2007 and executed in accordance with Resolution No. 9 of 16 January 2003 of ANVISA. Microbiological analyzes were performed at the Laboratório de Taxonomia, Bioquímica e Bioprospecção de Fungos do Instituto Oswaldo Cruz. A total of 2,978 fungi were isolated, where 30 % of the samples were positive for Aspergillus, giving a total of 360 strains isolated and identified to species level. The counts ranged from 1375 CFU/m3 air at 7 CFU/m3 air, and the most frequent species of the genus Aspergillus were A. flavus (24%), A. japonicus (16%), A. oryzae (15%), A. niger (15%), A. awamori (6%), A. fumigatus (4%). The highest counts were recorded in autumn and winter and the lowest were in the spring and summer, and correlation analysis showed a trend of relative humidity influencing contamination levels. After all the analysis we can conclude that it is necessary to establish standards grounded in research, considering the activities and the type of user, seeking new VMR values and indicating the important organisms as possible indicators in poor quality of indoor air.
7

IdentificaÃÃo de fungos carreados por formigas em hospitais terciÃrios do MunicÃpio de Fortaleza-CearÃ. / Identification of fungi carried by ants Tertiary Hospitals in the city of Fortaleza, CearÃ.

Lydia Dayanne Maia Pantoja 27 August 2008 (has links)
Estudos demonstram que os hospitais sÃo locais propÃcios para a instalaÃÃo e proliferaÃÃo de determinados insetos. Essa situaÃÃo à particularmente preocupante, pois alguns insetos, como as formigas, apresentam o potencial de carrear microrganismos em sua superfÃcie. O objetivo deste estudo foi avaliar a capacidade das espÃcies de formigas presentes em dois hospitais terciÃrios do MunicÃpio de Fortaleza, Cearà de carrear espÃcies fÃngicas, buscando uma correlaÃÃo com a microbiota fÃngica do ar. No perÃodo entre marÃo de 2007 a fevereiro de 2008, 2.899 formigas foram capturadas nos dois hospitais. A fauna de formigas foi amostrada mensalmente, em dois turnos, por meio da disposiÃÃo de iscas atrativas nÃo tÃxicas. Concomitantemente à coleta das formigas, por meio da sedimentaÃÃo passiva em placas de Petri, contendo Ãgar Sabouraud 2% de dextrose, foi possÃvel isolar e identificar fungos presentes no ar dos ambientes hospitalares. Para a identificaÃÃo entomolÃgica, uma amostra das formigas capturadas em cada isca foi enviada ao LaboratÃrio de Entomologia da Universidade Estadual do CearÃ, sendo classificadas por critÃrios morfolÃgicos. Simultaneamente, outra amostra das formigas capturadas de cada isca foi encaminhada ao Centro Especializado em Micologia MÃdica. A identificaÃÃo micolÃgica foi realizada mediante cultivo em meios de cultura, que eram semeados e incubados a 26 â 28ÂC por atà 15 dias, sendo identificados por anÃlise macro e micromorfologica, perfil bioquÃmico e utilizaÃÃo de meio cromogÃnico. Foram identificados cinco gÃneros e 13 espÃcies de formigas, presentes em Ãreas crÃticas (8% das formigas coletadas) e semicrÃticas (92%) e nos perÃodos diurno (48% das formigas coletadas) e noturno (52%). Na anÃlise micolÃgica, observou-se que 75% das formigas carreavam fungos, sendo a espÃcie Tapinoma melanocephalum e as espÃcies do gÃnero Pheidole as com maior potencial carreador de fungos anemÃfilos (75% e 18%, respectivamente) e de leveduras (6% e 1%, respectivamente). Dentre os fungos anemÃfilos, os gÃneros Aspergillus (46%), Penicillium (18,5%) e Cladosporium (7%) foram os mais comuns na superfÃcie externa das formigas. Com relaÃÃo ao grupo de leveduras, destacou-se o gÃnero Candida (70% dos isolados). Ao comparar os dados referentes Ãs cepas fÃngicas encontradas no ar com as cepas fÃngicas encontradas na superfÃcie externa das formigas, nÃo se estabeleceu qualquer tipo de correlaÃÃo estatÃstica, embora os gÃneros fÃngicos encontrados na microbiota fÃngica do ar e na microbiota fÃngica das formigas sejam semelhantes. Em suma, as formigas atuam como carreadoras de fungos anemÃfilos e leveduras, incluindo algumas espÃcies patogÃnicas, sendo a vigilÃncia entomolÃgica e o monitoramento sistematizado do ar, de grande importÃncia para a saÃde hospitalar. / Estudos demonstram que os hospitais sÃo locais propÃcios para a instalaÃÃo e proliferaÃÃo de determinados insetos. Essa situaÃÃo à particularmente preocupante, pois alguns insetos, como as formigas, apresentam o potencial de carrear microrganismos em sua superfÃcie. O objetivo deste estudo foi avaliar a capacidade das espÃcies de formigas presentes em dois hospitais terciÃrios do MunicÃpio de Fortaleza, Cearà de carrear espÃcies fÃngicas, buscando uma correlaÃÃo com a microbiota fÃngica do ar. No perÃodo entre marÃo de 2007 a fevereiro de 2008, 2.899 formigas foram capturadas nos dois hospitais. A fauna de formigas foi amostrada mensalmente, em dois turnos, por meio da disposiÃÃo de iscas atrativas nÃo tÃxicas. Concomitantemente à coleta das formigas, por meio da sedimentaÃÃo passiva em placas de Petri, contendo Ãgar Sabouraud 2% de dextrose, foi possÃvel isolar e identificar fungos presentes no ar dos ambientes hospitalares. Para a identificaÃÃo entomolÃgica, uma amostra das formigas capturadas em cada isca foi enviada ao LaboratÃrio de Entomologia da Universidade Estadual do CearÃ, sendo classificadas por critÃrios morfolÃgicos. Simultaneamente, outra amostra das formigas capturadas de cada isca foi encaminhada ao Centro Especializado em Micologia MÃdica. A identificaÃÃo micolÃgica foi realizada mediante cultivo em meios de cultura, que eram semeados e incubados a 26 â 28ÂC por atà 15 dias, sendo identificados por anÃlise macro e micromorfologica, perfil bioquÃmico e utilizaÃÃo de meio cromogÃnico. Foram identificados cinco gÃneros e 13 espÃcies de formigas, presentes em Ãreas crÃticas (8% das formigas coletadas) e semicrÃticas (92%) e nos perÃodos diurno (48% das formigas coletadas) e noturno (52%). Na anÃlise micolÃgica, observou-se que 75% das formigas carreavam fungos, sendo a espÃcie Tapinoma melanocephalum e as espÃcies do gÃnero Pheidole as com maior potencial carreador de fungos anemÃfilos (75% e 18%, respectivamente) e de leveduras (6% e 1%, respectivamente). Dentre os fungos anemÃfilos, os gÃneros Aspergillus (46%), Penicillium (18,5%) e Cladosporium (7%) foram os mais comuns na superfÃcie externa das formigas. Com relaÃÃo ao grupo de leveduras, destacou-se o gÃnero Candida (70% dos isolados). Ao comparar os dados referentes Ãs cepas fÃngicas encontradas no ar com as cepas fÃngicas encontradas na superfÃcie externa das formigas, nÃo se estabeleceu qualquer tipo de correlaÃÃo estatÃstica, embora os gÃneros fÃngicos encontrados na microbiota fÃngica do ar e na microbiota fÃngica das formigas sejam semelhantes. Em suma, as formigas atuam como carreadoras de fungos anemÃfilos e leveduras, incluindo algumas espÃcies patogÃnicas, sendo a vigilÃncia entomolÃgica e o monitoramento sistematizado do ar, de grande importÃncia para a saÃde hospitalar. / Studies show that hospitals are propitious sites for the establishment and proliferation of certain insects. This situation is of particular concern because some insects, such as ants, can carry microorganisms on their body surfaces. The aim of this study was evaluate capacity to the ant species present in two tertiary public hospitals in the city of Fortaleza, CearÃ, to carry fungi and to establish a correlation with the airborne fungal microbiota. From March 2007 to February 2008, 2,899 ants were evaluated at two hospitals. The ant communities were sampled monthly, during two periods (day and night), by setting out nontoxic baited traps. Along with collection of the ants, the fungi present in the air of the hospital environments were isolated and identified through the passive sedimentation method in Petri dishes containing Sabouraud dextrose agar. To identify the ant species, a sample from each trap was sent to the Entomology Laboratory of State University of CearÃ, where the ants captured were classified by morphological criteria. Another sample of the captured ants from each trap was sent to the Specialized Medical Mycology Center of the same university. The mycological identification was done by growth in culture media, seeded and incubated at 26-28ÂC for up to 15 days, with identification through macro and micromorphological analysis, biochemical profiling and growth in chromogenic medium. From this study, five genera and thirteen species of ants were identified, from the hospitalsâ critical areas (8% of the collected ants) and semi-critical areas (92%), during the daytime (48%) and nighttime (52%) periods. In the mycological analysis, 75% of the ants were fungi carriers, with Tapinoma melanocephalum and species from the genus Pheidole having the most potential as carriers of airborne fungi (75% and 18%, respectively) and yeasts (6% and 1%, respectively). Among the airborne fungi identified, those belonging to the Aspergillus (46%), Penicillium (18.5%) and Cladosporium (7%) genera were most common on the antsâ body surfaces. The predominant yeasts belonged to the Candida genus (70% of those isolated). Comparison of the fungal strains found in the air with those found on the ants did not establish any statistic correlation between the two fungal microbiotas. In summary, ants act as potential vectors of airborne fungi and yeasts, including some pathogenic species. Therefore, vigilance against insects and systematic air monitoring are important measures to ensure the healthfulness of hospital environments. / Studies show that hospitals are propitious sites for the establishment and proliferation of certain insects. This situation is of particular concern because some insects, such as ants, can carry microorganisms on their body surfaces. The aim of this study was evaluate capacity to the ant species present in two tertiary public hospitals in the city of Fortaleza, CearÃ, to carry fungi and to establish a correlation with the airborne fungal microbiota. From March 2007 to February 2008, 2,899 ants were evaluated at two hospitals. The ant communities were sampled monthly, during two periods (day and night), by setting out nontoxic baited traps. Along with collection of the ants, the fungi present in the air of the hospital environments were isolated and identified through the passive sedimentation method in Petri dishes containing Sabouraud dextrose agar. To identify the ant species, a sample from each trap was sent to the Entomology Laboratory of State University of CearÃ, where the ants captured were classified by morphological criteria. Another sample of the captured ants from each trap was sent to the Specialized Medical Mycology Center of the same university. The mycological identification was done by growth in culture media, seeded and incubated at 26-28ÂC for up to 15 days, with identification through macro and micromorphological analysis, biochemical profiling and growth in chromogenic medium. From this study, five genera and thirteen species of ants were identified, from the hospitalsâ critical areas (8% of the collected ants) and semi-critical areas (92%), during the daytime (48%) and nighttime (52%) periods. In the mycological analysis, 75% of the ants were fungi carriers, with Tapinoma melanocephalum and species from the genus Pheidole having the most potential as carriers of airborne fungi (75% and 18%, respectively) and yeasts (6% and 1%, respectively). Among the airborne fungi identified, those belonging to the Aspergillus (46%), Penicillium (18.5%) and Cladosporium (7%) genera were most common on the antsâ body surfaces. The predominant yeasts belonged to the Candida genus (70% of those isolated). Comparison of the fungal strains found in the air with those found on the ants did not establish any statistic correlation between the two fungal microbiotas. In summary, ants act as potential vectors of airborne fungi and yeasts, including some pathogenic species. Therefore, vigilance against insects and systematic air monitoring are important measures to ensure the healthfulness of hospital environments.

Page generated in 0.4068 seconds