101

Life-cycle cost analysis and probabilistic cost estimating in engineering design using an air duct design case study

Asiedu, Yaw 01 January 2000 (has links)
Although the issue of uncertainties in cost model parameters has been recognized as an important aspect of life-cycle cost analysis, it is often ignored or not well treated in cost estimating. A simulation approach employing kernel estimation techniques and their asymptotic properties in the development of the probability distribution functions (PDFs) of cost estimates is proposed. This eliminates the guess work inherent in current simulation based cost estimating procedures, reduces the amount of data sampled and makes it easier to specify the accuracy desired in the estimated distribution. Building energy costs can be reduced considerably if air duct systems are designed for the least life-cycle cost. The IPS-Method, a simple approach to HVAC air duct design is suggested. The Diameter and Enhanced Friction Charts are also developed. These are charts that implicitly incorporate the LCC and are better than the existing Friction Chart for the selection of duct sizes. Through illustrative examples, the ease and effectiveness of these are demonstrated. For more complex designs, a Segregated Genetic Algorithm (SGA) is recommend. A sample problem with variable time-of-day operating conditions and utility rates is used to illustrate its capabilities. The results are compared to those obtained using weighted average flow rates and utility rates to show the life-cycle cost savings possible by using this approach. Although life-cycle cost savings may be only between 0.4% and 8.3% for some simple designs, much larger savings may occur with more complex designs and operating constraints. The SGA is combined with probabilistic cost estimating to optimize HVAC air duct systems with uncertainties in the model parameters. The designs based on the SGA method tended to be less sensitive to typical variations in the component physical parameters and, therefore, are expected to result in lower balancing and operating costs.
102

The effect of energy recovery on indoor climate, air quality and energy consumption using computer simulations

Fauchoux, Melanie 23 June 2006 (has links)
The main objectives of this thesis are to determine if the addition of an energy wheel in an HVAC system can improve the indoor air relative humidity (RH), and perceived air quality (PAQ), as well as reduce energy consumption. An energy wheel is an air-to-air energy exchanger that transfers heat and moisture between the outdoor air entering and the exhaust air leaving a building. This thesis uses the TRNSYS computer package to model two buildings (an office and a school) in four different cities (Saskatoon, Saskatchewan; Vancouver, British Columbia; Tampa, Florida and Phoenix, Arizona).<p>The results with and without an energy wheel are compared to see if the energy wheel has a significant impact on the RH and PAQ in the buildings. The energy wheel reduces peak RH levels in Tampa, (up to 15% RH), which is a humid climate, but has a smaller effect on the indoor RH in Saskatoon (up to 4% RH) and Phoenix (up to 11% RH), which are dry climates. The energy wheel also reduces the number of people that are dissatisfied with the PAQ within the space by up to 17% in Tampa. <p>The addition of the energy wheel to the HVAC system creates a reduction in the total energy consumed by the HVAC system in Saskatoon, Phoenix and Tampa (2% in each city). There is a significant reduction in the size of the heating equipment in Saskatoon (26%) and in the size of the cooling equipment in Phoenix (18%) and Tampa (17%). A cost analysis shows that the HVAC system including an energy wheel has the least life-cycle costs in these three cities, with savings of up to 6%. In Vancouver, the energy wheel has a negligible impact on the indoor RH, PAQ and energy consumption.
103

Design and performance testing of counter-cross-flow run-around membrane energy exchanger system

Mahmud, Khizir 29 September 2009 (has links)
In this study, a novel counter-cross-flow run-around membrane energy exchanger (RAMEE) system was designed and tested in the laboratory. The RAMEE system consists of two (2) counter-cross-flow Liquid-to-Air Membrane Energy Exchangers (LAMEEs) to be located in the supply and exhaust air streams in the building Heating Ventilation and Air-Conditioning (HVAC) system. Inside each exchanger, a micro-porous membrane separates the air and liquid streams and allows transfer of the sensible and latent energy from the air stream to the liquid stream or vice-versa. The system exchanges sensible and latent energy between supply and exhaust air streams using a desiccant solution loop. The supply and exhaust air streams in the RAMEE can be located far apart from each other or adjacent to each other. The flexibility of non-adjacent ducting makes the RAMEE system a better alternative compared to available energy recovery systems for the retrofit of HVAC systems.<p> Two counter-cross-flow exchangers for the RAMEE system were designed based on an industry recommended standard which is to obtain a target overall system effectiveness of 65% for the RAMEE system at a face velocity of 2 m/s. The exchanger design was based on heat exchanger theory and counter-cross-flow design approach. An exchanger membrane surface aspect ratio (ratio of exchanger membrane surface height to exchanger length) of 1/9 and the desiccant solution entrance ratio (ratio of desiccant solution entrance length to exchanger length) of 1/24 were employed. Based on different heat transfer case studies, the energy transfer size of each exchanger was determined as 1800 mm x 200 mm x 86 mm. ProporeTM was used as the membrane material and Magnesium-Chloride solution was employed as the desiccant solution.<p> The RAMEE performance (sensible, latent and total effectiveness) was evaluated by testing the system in a run-around membrane energy exchanger test apparatus by varying the air stream and liquid solution-flow rates at standard summer and winter operating conditions. From the test data, the RAMEE effectiveness values were found to be sensitive to the air and solution flow rates. Maximum total effectiveness of 45% (summer condition) and 50% (winter condition) were measured at a face velocity ¡Ö 2 m/s. A comparison between the experimental and numerical results from the literature showed an average absolute discrepancy of 3% to 8% for the overall total system effectiveness. At a low number of heat transfer units, i.e. NTU = 4, the numerical and experimental results show agreement within 3% and at NTU = 12 the experimental data were 8% lower than the simulations. The counter-cross-flow RAMEE total system effectiveness were found to be 10% to 20% higher than those reported for a cross-flow RAMEE system by another researcher.<p> It is thought that discrepancies between experimental and predicted results (design and numerical effectiveness) may be due to the mal-distributed desiccant solution-flow, desiccant solution leakage, lower than expected water vapor permeability of the membrane, uncertainties in membrane properties (thickness and water vapor permeability) and heat loss/gain effects. Future research is needed to determine the exact cause of the discrepancies.
104

Run-around membrane energy exchanger performance and operational control strategies

Erb, Blake 18 January 2010 (has links)
A run-around membrane energy exchanger (RAMEE) is a novel energy exchanger that is capable of transferring both heat and moisture, which can significantly reduce the energy required to condition outdoor ventilation air. The RAMEE uses a liquid desiccant to transfer both heat and moisture between two remote air streams, making it appropriate for many applications, including building HVAC retro-fits. Both initial system start-up and changing outdoor conditions require time for the desiccant to undergo changes in both temperature and concentration, and can cause significant transient delays in system performance. Under some conditions, these transients may be beneficial by increasing the system performance. However under some conditions, the transient delays can cause a substantial decrease in performance.<p> This thesis focuses on the development of control strategies that can be used to reduce unwanted transient delays. In order to develop these control strategies, the performance of a RAMEE is first investigated using both experimental and numerical methods. The transient numerical and experimental effectiveness results show satisfactory agreement, with a maximum root mean squared error of 10%. Both the numerical and experimental data show that a long transient time of several hours, or even several days, can occur upon initial system start-up.<p> The numerical model is used to investigate several control strategies to reduce unwanted transient delays. The control strategies investigated are: solution and air flow control, air flow bypass, solution temperature control, and solution concentration control. The solution and air flow control are shown to reduced the start-up transient time by up to 11%, but require either a reduction in air flow or an increase in solution pumping costs. Air flow bypass proves to be a better option which provides a 16% reduction in transient time, and only requires that a bypass damper be provided for each exchanger. Solution temperature control is capable of essentially eliminating the thermal transient time (time required for the solution to reach operating temperature), but the thermal transient time is found to be a minor contributor to the overall transient time (time required for the solution to reach operating temperature and concentration) when the initial concentration of the solution is different than the steady-state concentration. When thermal and moisture transients exist, total transient times may be over 18 days. A practical temperature and concentration control strategy is developed, which can reduce transient delays by over 90% and increase performance during variable outdoor weather conditions.
105

Development of BEMS Diagnostic and Intelligent Expert Technology for Air-conditioning Systems

Dai, Chi-fu 11 June 2012 (has links)
When central HVAC systems are under commercial operation, all operational parameters, including chilled water supply temperature, return water temperature, chilled water flow rate, and power consumption as the key factors in affecting system energy efficiency.However, in Taiwan there is still lacking of the regression equations of chillers under local weather conditions, and has to rely on manual operation based on experiences. This is also the major short-comings in implementing TAB, and is the best way to renovate the green buildings to make them more intelligent. In this study, theoretical analysis and experimental investigation will be applied simultaneously. In selecting cases from the BeeUp program, actual operational data including COP can be fitted into experimental model to facilitate TAB engineering via BEMS system, in achieving system efficiency. Through the execution of this project, it is identified that the exhibition buildings with 10 hours cooling load, can achieve 7% energy savings. The good result obtained in this project , including the thermal energy storage HVAC system and the heat pump system can be widely adapted to obtain significant energy conservation effect.
106

Modeling Building Energy Use and HVAC Efficiency Improvements in Extreme Hot and Humid Regions

Bible, Mitchell 2011 August 1900 (has links)
An energy analysis was performed on the Texas A & M University at Qatar building in Doha, Qatar. The building and its HVAC systems were modeled using EnergyPlus. Building chilled water and electrical data were collected to validate the computer simulation. The simulated monthly electricity consumption was within plus/minus 5 percent of the metered building data. Ninety-five percent of simulated hourly electricity data in a day were within plus/minus 10 percent of metered data. Monthly chilled water demand was within plus/minus 18 percent of measurements, and simulated monthly demand was correlated to metered monthly values with an R-squared correlation coefficient of 0.95. Once the simulation was verified with the metered data, an optimization of the building's HVAC systems was performed. Better utilizing the building's variable speed fans at part loads showed potential annual electricity savings of 16 percent over the base case, with another 22 percent savings in chilled water energy. After converting chilled water savings to equivalent chiller electricity savings, the potential utility cost savings over the base case were found to be $90,000/yr at local utility rates. Reducing outdoor air intake to ASHRAE indoor air quality minimums yielded an additional 17 percent in potential chilled water savings and brought total monetary savings over the base case to $110,000/yr. Using a dedicated outside air system to precisely control individual zone ventilation showed potential for an additional 12 percent chilled water savings and $14,000 in yearly utility savings, while also eliminating cases of under-ventilation. A hypothetical retrofit of fan powered terminal units (FPTU's) resulted in energy savings only at very low minimum flow rates, below ventilation standards. Savings were never more than 20 percent over the no-fan case. Series FPTU's showed no savings at any flow setting and negligible difference was found between ECM and SCR motor control. Finally, the dependence on climate of each improvement was studied. Simulations were run in the relatively milder climates of Houston and Phoenix and compared to those found for Doha. It was found that variable speed fan operation is a more cost effective option for milder climates, while outside air control is more cost effective in extreme hot and humid climates such as Doha. Future study is needed to make the FPTU model valid for different climates and flow ranges.
107

A Study on Off-shore Wind Farm Power Transmission for Grid Interconnection

Chang, Chi-Wen 19 January 2007 (has links)
The interest in the utilization of offshore wind power is increasing significantly. Due to the shortage of in-land locations for wind farm and the wind speed offshore is potentially higher than that of onshore, which leads to a much higher power production. In this thesis a large offshore wind farm is modeled using Matlab simulation package. In the simulations active stall regulated wind turbines driving fixed speed asynchronous generators are used. Two different types of interconnections are modeled and compared, one is the Voltage Source Converter (VSC) based HVDC link and the other one uses high voltage AC (HVAC) cable interconnection. Transmission faults are simulated in each system and the transient response are examined. Three phase fault and single line to ground fault are used to compare the performance of the VSC based HVDC interconnection system and HVAC interconnection. It is found that compared to the traditional HVAC transmission, the VSC based HVDC transmission would have better performance under various system disturbances.
108

Adaptable, scalable, probabilistic fault detection and diagnostic methods for the HVAC secondary system

Li, Zhengwei 30 March 2012 (has links)
As the popularity of building automation system (BAS) increases, there is an increasing need to understand/analyze the HVAC system behavior with the monitoring data. However, the current constraints prevent FDD technology from being widely accepted, which include: 1)Difficult to understand the diagnostic results; 2)FDD methods have strong system dependency and low adaptability; 3)The performance of FDD methods is still not satisfactory; 4)Lack of information. This thesis aims at removing the constraints, with a specific focus on air handling unit (AHU), which is one of the most common HVAC components in commercial buildings. To achieve the target, following work has been done in the thesis. On understanding the diagnostic results, a standard information structure including probability, criticality and risk is proposed. On improving method's adaptability, a low system dependency FDD method: rule augmented CUSUM method is developed and tested, another highly adaptable method: principal component analysis (PCA) method is implemented and tested. On improving the overall FDD performance (detection sensitivity and diagnostic accuracy), a hypothesis that using integrated approach to combine different FDD methods could improve the FDD performance is proposed, both deterministic and probabilistic integration approaches are implemented to verify this hypothesis. On understanding the value of information, the FDD results for a testing system under different information availability scenarios are compared. The results show that rule augmented CUSUM method is able to detect the abrupt faults and most incipient faults, therefore is a reliable method to use. The results also show that overall improvement of FDD method is possible using Bayesian integration approach, given accurate parameters (sensitivity and specificity), but not guaranteed with deterministic integration approach, although which is simpler to use. The study of information availability reveals that most of the faults can be detected in low and medium information availability scenario, moving further to high information availability scenario only slightly improves the diagnostic performance. The key message from this thesis to the community is that: using Bayesian approach to integrate high adaptable FDD methods and delivering the results in a probability context is an optimal solution to remove the current constraints and push FDD technology to a new position.
109

Whole-house mechanical ventilation in a mixed-humid climate

Capps, Laura 15 February 2012 (has links)
As building codes and green building programs require tighter home construction, the need for outdoor air ventilation to improve indoor air quality increases. Major improvements in building envelopes and duct systems have led to decreases in heating and cooling loads causing fewer HVAC system run-time hours, and increasing the probability for air stagnation within homes with poor outdoor air ventilation. ASHRAE Standard 62.2 quantifies the amount of whole-house ventilation required based on the number of occupants and the square footage of conditioned space, but leaves the design of the ventilation system up to the mechanical engineer or HVAC contractor. In 2010, ASHRAE began requiring flow testing for confirmation of outdoor air ventilation rates, yet few municipalities and green building programs have adopted the new standard. Builders in mixed-humid climates are forced to balance the need for outdoor air ventilation with the upfront costs for mechanical ventilation systems, and the potential for increased humidity loads and energy costs associated with mechanical ventilation strategies. One common solution employed in the southeastern United States involves a central fan integrated supply (CFIS) ventilation system controlled with an air-cycler for minimum run-time to meet ASHRAE Standard 62.2. While this system has been tested and proven to meet design ventilation rates, those tests were often conducted on homes constructed by well trained builders receiving strong oversight from building scientists and the design ventilation rates were not always ASHRAE compliant. The following report analyzes whether the CFIS ventilation system with air-cycler controller provides ventilation meeting ASHRAE Standard 62.2 when employed by builders with minimal training and support.
110

Characterizing the impacts of air-conditioning systems, filters, and building envelopes on exposures to indoor pollutants and energy consumption in residential and light-commercial buildings

Stephens, Brent Robert 03 July 2012 (has links)
Residential and light-commercial buildings comprise a significant portion of buildings in the United States. They account for a large fraction of the total amount of energy used in the U.S., and they also represent environments where people spend the majority of their time. Thus, the design, construction, and operation of these buildings and their systems greatly affect energy consumption and exposures to airborne pollutants of both indoor and outdoor origin. However, there remains a need to improve knowledge of some key source and removal mechanisms of indoor and outdoor pollutants in residential and light-commercial buildings, as well as their connections to energy use and peak electricity demand. Several standardized field test methods exist for characterizing energy use and indoor air quality in actual buildings, although few explicitly address residential and light-commercial buildings and they are generally limited in scope. Therefore, the work in this dissertation focuses on improving methods to characterize three particular building components for their impacts on exposures to indoor pollutants and their implications for energy consumption: (1) central forced-air heating and cooling (HAC) systems, (2) HAC filters, and (3) building envelopes. Specifically, the research in this dissertation is grouped to fulfill two primary objectives of developing and applying novel methods to: (1) characterize and evaluate central air-conditioning systems and their filters as pollutant removal devices in residential and light-commercial buildings, and to explore their implications for energy consumption, and (2) characterize and evaluate the ability of two particular outdoor pollutants of concern (ozone and particulate matter) to infiltrate indoors through leaks in building envelopes. The research in this dissertation is divided into four primary investigations that fulfill these two objectives. The first investigation (Investigation 1a) addresses Objective 1 by first providing a detailed characterization of a variety of operational characteristics measured in a sample of 17 existing central HAC systems in occupied residential and light-commercial buildings in Austin, Texas, and exploring their implications for exposure to indoor pollutants, energy use, and peak electricity demand. Among the findings in this study, central air-conditioning systems in occupied residential and light-commercial buildings did not operate most of the time, even in the hot and humid climate of Austin, Texas (i.e., ~25% of the time on average in the summer). However, average recirculation rates still make central air-conditioning systems competitive as particle removal mechanisms, given sufficient filtration efficiency. Additionally, this investigation used a larger, much broader, dataset of energy audits performed on nearly 5000 single-family homes in Austin to explore common inefficiencies in the building stock. Residential and light-commercial air-conditioning systems are often inefficient; in fact, residential central air-conditioning systems in particular likely account for nearly 20% of peak electric demand in the City of Austin. As much as 8% of peak demand could be saved by upgrading all single-family homes in Austin to higher-efficiency equipment. The second investigation (Investigation 1b) also addresses Objective 1 by developing and applying a novel test method for measuring the in-situ particle removal efficiency of HAC systems and filters in residential and light-commercial buildings. Results from the novel test method as performed with three test filters and 0.3–10 μm particles in an unoccupied test house agreed reasonably well with results from other field and laboratory test methods. Low-efficiency filters did not increase particle removal much more than simply running the HAC system without a filter, and higher-efficiency filters provided greater than ~50% removal efficiency for most particles greater than 1–2 μm in diameter. The benefit of this test method is that it can be used to measure how filters perform in actual environments, how filter removal efficiency changes with actual dust loading, and how much common HAC design and installation issues, such as low airflow rates, duct leakage, fouled coils, and filter bypass airflow, impact particle removal in real environments. The third investigation (Investigation 2a) addresses Objective 2 by developing and applying a novel test methodology for measuring the penetration of outdoor ozone, a reactive gas, through leaks in exterior building envelopes using a sample of 8 single-family residences in Austin, Texas. These measurements represent the first ever measurements of ozone penetration factors through building envelopes of which I am aware, and penetration factors were lower than the usual assumption of unity (i.e., P = 1) in seven of the eight test homes (ranging from 0.62±0.09 to 1.02±0.15), meaning that some building envelopes provide occupants with more protection from indoor exposures to ozone and ozone reaction byproducts than others. Additionally, ozone penetration factors were correlated with some building characteristics, including the amount of painted wood siding on the exterior envelope and the year of construction, suggesting that simple building details may be used to predict ozone infiltration into homes. Finally, the fourth investigation (Investigation 2b) also addresses Objective 2 by refining and applying a test methodology for measuring the penetration of ambient particulate matter through leaks in building envelopes, and using a sample of 19 single-family residences in Austin, Texas to explore correlations between experimentally-determined particle penetration factors and standardized fan pressurization air leakage tests. Penetration factors of particles 20–1000 nm in diameter ranged from 0.17±0.03 to 0.72±0.08 across 19 homes that relied solely on infiltration for ventilation air. Particle penetration factors were also significantly correlated with results from standardized fan pressurization (i.e., blower door) air leakage tests and the year of construction, suggesting that occupants of older and leakier homes are exposed to more particulate matter of outdoor origin than those in newer tighter homes. Additionally, blower door tests may actually offer some predictive ability of particle penetration factors in single-family homes, which could allow for vast improvements in making easier population exposure estimates. Overall, the work in this dissertation provides new methods and data for assessing the impacts of central air-conditioning systems, filters, and building envelopes on human exposure to indoor pollutants and energy use in residential and light-commercial buildings. Results from these four primary investigations will allow building scientists, modelers, system designers, policymakers, and health scientists to make better informed decisions and assumptions about source and removal mechanisms of indoor pollutants and their impacts on building energy consumption and peak electricity demand. / text