• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 10
  • 5
  • 2
  • 2
  • Tagged with
  • 51
  • 51
  • 13
  • 12
  • 10
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Morfologia da superficie e resistencia da união de ceramica IPS Empress Esthetic submetida a diferentes tratamentos / Bond strenght and surface/interface morphology of luting polymers and glass ceramic etched for different periods

Naves, Lucas Zago, 1981- 13 August 2018 (has links)
Orientadores: Lourenço Correr Sobrinho, Carlos Jose Soares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T12:11:57Z (GMT). No. of bitstreams: 1 Naves_LucasZago_M.pdf: 3732245 bytes, checksum: f19061d71b96dbce2d54cda8b37f2ba9 (MD5) Previous issue date: 2009 / Resumo: Este estudo avaliou a morfologia de superfície e resistência de união ao microcisalhamento entre a cerâmica reforçada por leucita IPS Empress Esthetic (Ivoclar- Vivadent) e o cimento resinoso Variolink II (Ivoclar-Vivadent), em diferentes tempos de condicionamento da cerâmica, com e sem aplicação do adesivo após o uso do silano. Setenta e dois discos cerâmicos (6mm de diâmetro x 2mm de espessura) foram confeccionados, embutidos em resina e divididos em 12 grupos (n=6), definidos pelo tempo condicionamento com ácido fluorídrico 10% e aplicação ou não de adesivo após o uso do silano: G1 e G7 - 10s de condicionamento ácido, G2 e G8 - 20 s; G3 e G9 - 40 s; G4 e G10 - 60 s; G5 e G11 - 120 s e G6 e G12 - 60 + 60s. O silano foi aplicado em todos os grupos e metade dos grupos (de G7 a G12) receberam uma camada do adesivo (Scotchbond MP - 3M/ESPE). Molde de elastômero com dois orifícios cilíndricos (1,2mm de diâmetro x 2mm de altura) foi adaptado sobre a superfície da cerâmica para a construção de dois cilindros por amostra, totalizando 12 cilindros por grupo. Para tal, os orifícios foram preenchidos com o cimento resinoso (Variolink II), fotoativados por 40 s e submetidos ao ensaio de resistência de união ao microcisalhamento a velocidade de 0,5mm/min. e o padrão de fratura foi analisado. Os dados foram submetidos à Análise de Variância e ao teste de Student-Newman-Keul (p<0,05). A topografia e a interface de união foram avaliadas em MEV. A resistência de união ao microcisalhamento (MPa) foi 19,4±3,5 (G1), 22,3±5,1 (G2), 22,2±3,2 (G3), 17,8±2,1 (G4), 15,3±3,0 (G5), 14,3±1,8 (G6) para os grupos tratados com silano, e 17,4±4,8 (G7), 21,3±2,1 (G8), 21,1±2,3 (G9), 24,7±5,8 (G10), 20,4±2,2 (G11) e 18,5±4,6 (G12) para os grupos tratados com silano + adesivo. Houve redução de falhas adesivas e aumento das mistas com o aumento do tempo de condicionamento para os grupos tratados com silano e equilíbrio da falhas adesivas e mistas para os grupos tratados com silano + adesivo, exceto para os grupos G11 e G12 onde houve predominância de falhas mistas. Pouca alteração na topografia de superfície foi detectada nas amostras condicionadas por 10s, canais apresentando sulcos profundos puderam ser notados em praticamente toda a extensão das superfícies cerâmicas recondicionadas (60+60s - G6 e G12). Espaços não-preenchidos ao longo da interface cerâmica-cimento resinoso foram detectados em intensidade crescente a partir de 60s de condicionamento, quando apenas o silano foi aplicado, enquanto um preenchimento homogêneo, caracterizado por íntimo contato com a cerâmica pode ser percebido quando o adesivo foi utilizado, exceto para o grupo recondicionado - G12. / Abstract: This study evaluated the influence of etching times on surface/interface morphology and micro-shear bond strength to Empress Esthetic leucite-reinforced glass ceramic (Ivoclar-Vivadent), with or without application of an unfilled resin after silane. Ceramic discs were divided into 12 groups (n = 6), defined by the etching time with 10% hydrofluoric acid: G1 and G7 - etching for 10s, G2 and G8 - 20 s; G3 and G9 - 40 s; G4 and G10 - 60 s; G5 and G11 - 120 s and G6 and G12 - 60 + 60s. Half of the groups (G7 to G12) received a layer of unfilled resin (Scotchbond MP/ 3M ESPE) after silane coupling. Micro-shear bonding test using Variolink II resin cement (Ivoclar-Vivadent) was performed, and data submitted to two-way ANOVA and Student-Newman-Keuls' test (p < 0.05). Evaluation of the etching pattern and bonding interfaces was conducted by Scanning Electron Microscopic (SEM). Means micro-shear bond strengths (MPa) were 19.4±3.5 (G1), 22.3±5.1 (G2), 22.2±3.2 (G3), 17.8±2.1 (G4), 15.3±3.0 (G5), 14.3±1.8 (G6) for groups treated with silane, and 17.4±4.8 (G7), 21.3±2.1 (G8), 21.1±2.3 (G9), 24.7±5.8 (G10), 20.4±2.2 (G11) e 18.5±4.6 (G12) for groups treated with silane and unfilled resin. Poor etching topography was detected on 10s etched surfaces, whereas fissures forming deep grooved channels were extensively observed in 120s and 60+60s ceramics surfaces. Unfilled spaces underlying the ceramic-resin cement interface were detected when only silane was applied. Fully completion of the irregularities on 60s and 120s samples were detected using the unfilled resin, although this material was unable to completely fill the irregularities on 60+60s (G12) ceramic. When only silane was applied, the 60s and the groups etched for longer periods (120 and 60+60s - G5 and G6) showed lower bond strengths, but when both silane and unfilled resin were applied, all etching times generally showed similar values. The etching protocol influenced the surface/interface topography and bond strength to ceramic. The application of unfilled resin was able to infiltrate all unfilled spaces beneath the ceramic-resin cement interface detected when only silane was applied, except on the re-etched (60+60s - G12) ceramic. / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
32

Avaliação da resistência de união entre cimento e uma vitro cerâmica condicionada com diferentes tempos de ácido fluorídrico 5% e 10% - estudo in vitro / Assessment of bond strength between a cement and a glass-ceramic etched at different times with 5% and 10% hydrofluoric acid - in vitro study

Veronese, Carolina Bauer Godoy 23 May 2017 (has links)
Submitted by Rosangela Silva (rosangela.silva3@unioeste.br) on 2018-05-28T12:46:38Z No. of bitstreams: 2 Carolina Bauer Godoy Veronese.pdf: 1949543 bytes, checksum: 5867490bfd176654b3782263890bdf9a (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-05-28T12:46:38Z (GMT). No. of bitstreams: 2 Carolina Bauer Godoy Veronese.pdf: 1949543 bytes, checksum: 5867490bfd176654b3782263890bdf9a (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-05-23 / Objective: to assess the effect of different hydrofluoric acid (HF) etching times at concentrations of 5% and 10% on the bond strength of RelyX Ultimate resin cement to a zirconia-reinforced lithium silicate ceramic of commercial brand Vita Suprinity (VS), for which the manufacturer recommends using 5% HF for 20". Method: experimental and completely randomized study with 8 treatments (n=8). Each ceramic sample was etched with hydrofluoric acid (HF) at different times and concentrations: 5% for 20, 30, 40, and 60 s, and 10% for 10, 20, 30, and 40 s; subjected to roughness (Ra) analysis, followed by the cementation protocol applying hydrofluoric acid, RelyX Ceramic Primer silane, Single Bond Universal adhesive, and RelyX Ultimate resin cement. Bond strength was assessed by the microshear test followed by fracture pattern analysis. Results: the 5%/20" treatment showed the statistically lowest bond strength of 21.96 MPa (p<0.01), differing from 10% HF treatment at the four times studied: 10" = 29.59 MPa, 20" = 29.77 MPa, 30" = 29.68 MPa, and 40" = 30.78 MPa (p<0.01). The 10%/40" treatment showed the highest bond strength (30.78 MPa), differing only from 5%/20" (21.96 MPa). The fracture pattern was predominantly adhesive. Conclusion: hydrofluoric acid etching increases surface roughness of the Vita Suprinity ceramic at both concentrations and their different times of exposure, showing significant differences in adhesive bond strength only when concentration and etching time vary widely, and with mostly adhesive rupture occurring in the adhesive interface. The concentration of 5% hydrofluoric acid for 30" or 10% for 10" or 20" showed higher bond strength than the manufacturer's protocol, but there were no wide and shallow porosities in SEM. This suggests the increase in exposure time recommended by the manufacturer from 20" to 30" or the use of higher concentrations of acid, such as 10% at 10" or 20", for more effective results. / Objetivo: Avaliar o efeito de diferentes tempos de condicionamento com ácido fluorídrico (HF) nas concentrações de 5% e 10 % na resistência de união do cimento resinoso RelyX Ultimate a uma cerâmica de silicato de lítio reforçada com zircônia de nome comercial Vita Suprinity (VS), onde a indicação do fabricante é a utilização de HF a 5% durante um tempo de 20”. Metodologia: Estudo realizado com delineamento experimental inteiramente casualizado, com 8 tratamentos (n=8). Cada espécime de cerâmica foi condicionado com ácido fluorídrico (HF) em diferentes tempos e concentrações: 5% por 20, 30, 40 e 60 seg, e 10% por 10, 20, 30 e 40 seg; submetidas à análise da rugosidade (Ra), seguido pelo protocolo de cimentação empregando ácido fluorídrico, silano RelyX Ceramic Primer, adesivo Single Bond Universal e cimento resinoso RelyX Ultimate. A resistência de união foi avaliada pelo teste de microcisalhamento; seguido pela análise do padrão das fraturas. Resultados: O tratamento 5%/20” exibiu estatisticamente a menor resistência de união 21,96 MPa (p<0.01), diferindo do tratamento com HF a 10% nos quatro tempos estudados, 10” = 29,59 MPa, 20” = 29,77 Mpa, 30”= 29,68 Mpa e 40”= 30,78 Mpa (p<0.01); o tratamento 10%/40” exibiu a maior resistência de união (30,78 MPa), diferindo apenas do 5%/20” (21,96 MPa). O padrão de fraturas foi predominantemente adesivo. Conclusão: O condicionamento com ácido fluorídrico, em ambas concentrações e em seus diferentes tempos de exposição, aumenta a rugosidade da superfície da cerâmica Vita Suprinity, havendo diferenças significativas na resistência da união adesiva apenas quando a concentração e o tempo de condicionamento variam grandemente, e a maioria da ruptura foi adesiva, ocorrendo na interface do adesivo; com ácido fluorídrico na concentração de 5% durante 30” ou 10% por 10” ou 20” observou-se maior resistência de união do que o protocolo do fabricante, contudo sem observar porosidades amplas e rasas em MEV, sugerindo aumentarmos o tempo de exposição sugerido pelo fabricante de 20” para 30” ou utilizar ácido com concentração maior, como por exemplo 10% em 10” ou 20”, para resultados mais efetivos.
33

Influência do tempo de condicionamento ácido na alteração superficial, resistência de união e compressão da cerâmica de dissilicato de lítio / Influence of etching time on the superficial alterations, bond strength and compression resistence of lithium disilicate ceramic

Tostes, Bhenya Ottoni 21 October 2016 (has links)
Este estudo in vitro propôs analisar os padrões de condicionamento da superfície da cerâmica a base de dissilicato de lítio após três tempos de condicionamento com ácido fluorídrico a 10%, a influência desses tempos na resistência ao cisalhamento de cilindros cerâmicos e à compressão de placas cerâmicas cimentadas em esmalte de dentes bovinos. Para análise de superfície foram utilizadas 36 placas de cerâmica (IPS e.max Press), sem tratamento e condicionadas por 10s, 20s e 60s (E0,E10,E20,E60; n=3), observadas em MEV, energia dispersiva espectroscópica (EDS) e perfilômetro. Para o teste de resistência de união, 180 cilindros cerâmicos (2mm diâmetro x 2mm comprimento; n=20) foram condicionados e cimentados (80 m de espessura) com RelyX ARC em esmalte variando os sistemas adesivos {Silano+Single Bond (S); RelyX Ceramic Primer Silano +Single Bond (R); Single Bond Universal (U)}, obtendo-se os grupos: E10S, E20S, E60S, E10R, E20R, E60R, E10U, E20U e E60U. Após 24h realizou-se o teste de cisalhamento (EMIC, 0,5mm/min, 50Kgf). O teste de compressão ao esmalte (Kratos, 0,5mm/min 50Kgf) foi realizado após 24h da cimentação de 60 placas cerâmicas quadradas (5x5mm com 1mm de espessura; n=10), condicionadas e cimentadas (RelyX ARC, 80m) variando os sistemas adesivos R e U (10R, 20R, 60R, 10U, 20U e 60U). Os resultados da análise em MEV mostraram que foi mantido o mesmo padrão de condicionamento, porém, mais evidenciado com o aumento do tempo de tratamento. A quantidade de sílicio observada em EDS foi: E0:24,73% < E10:61,10% < E20:67,50% = E60:67,54% e a rugosidade: E0: 6,25 m < E10: 10,6m < E20: 12,0m < E60: 18,0m. Para os resultados dos ensaios de cisalhamento foi usado um modelo linear generalizado, com distribuição normal para a variável resposta e função de ligação do tipo raiz quadrada. Para compressão, usamos um modelo linear normal. Em ambos os casos, a hipótese de normalidade dos desvios foi verificada a partir do Q-Q Plot e do Teste de Kolmogorov-Smirnov. Para os testes de cisalhamento (MPa), independente do tempo de condicionamento, o grupo S apresentou os menores valores, enquanto os grupos R e U apresentaram valores semelhantes (E10S:84,2±7,2A/a, E10R:124,4±7,9A/b, E10U:117,2±7,8A/b, E20S:102,3±7,6B/a, E20R:146,2±8,2B/b, E20U:138,4±7,9B/b, E60S:107,2±7,8B/a, E60R:152,1±8,1B/b, E60U:144,1±8,1B/b). Para o teste de compressão (N), os valores Médios foram: 10R:869,8±122a, 10U:879,3±159a, 20R:795,0±219ab, 20U:852,3±227ab, 60R:772,7±162b, 60U:704,0±235b. O aumento do tempo de condicionamento da superfície da cerâmica a base de dissilicato de lítio aumentou a rugosidade superficial, não demonstrou diferença significativa da resistência de união de 20s par 60s, e apresentou leve diminuição para resistência de compressão. / The present in vitro study aimed to analyze the etching patterns of lithium disilicate based ceramic after three etching times with 10% hydrofluoric acid, and the influence of these times on the shear bond strength of ceramic cylinders and compression resistance of ceramic plates cemented to bovine enamel teeth. For the surface analysis, 36 ceramic plates (IPS e.max Press) were used untreated and etched for 10s, 20s and 60s (E0, E10, E20, E60; n = 3), as observed in SEM, energy dispersive spectroscopy (EDS) and profilometry. For the bond strength test, 180 ceramic cylinders (2x2mm; n = 20) were etched and cemented with RelyX ARC (80 m thick) on the enamel varying adhesive systems {Silane + Single Bond (S); RelyX Ceramic Primer Silane + Single Bond (R); Single Bond Universal (U)}, yielding the groups: E10S, E20S, E60S, E10R, E20R, E60R, E10U, E20U and E60U. After 24h, the shear bond strength test was performed (EMIC, 0.5 mm/min, 50Kgf). The ceramic compression test (Kratos, 0.5 mm/min, 50Kgf) was performed 24h after etching and cementing (RelyX ARC, 80m) 60 square ceramic plates (5x5mm, 1mm thick; n = 10), varying R and U adhesive systems (10R, 20R, 60R, 10U, 20U and 60U). The same pattern of damage was maintained as seen in the SEM analysis, however, it worsened with increasing the etching time. The amounts of silicium seen on EDS were: E0: 24.73% &lt;E10: 61.10% &lt;E20: 67.50% = E60: 67.54% and roughness: E0: 6.25 m &lt;E10: 10.6m &lt;E20: 12.0m &lt;E60: 18.0m. For the results of the shear bond test, a generalized linear model with normal distribution was used for the response variable and link function of the square root type. For the compression test, a standard linear model was used. In both cases, the deviations of the hypothesis of normality were verified from a Q-Q plot and the Kolmogorov-Smirnov test. For the shear bond strength test (MPa), regardless of the etching time, the S group showed the lowest values, while the R and U groups had similar values (E10S: 84.2±7.2A/a, E10R: 124.4±7.9A/b, E10U: 117.2±7.8A/b, E20S:102.3±7.6 B/a, E20R:146.2±8.2B/b, E20U:138.4±7.9B/b, E60S:107.2±7.8B/a, E60R:152.1±8.1B/b, E60U: 144.1±8.1B/b). For the compression test (N), the mean values were: 10R: 869.8±122 a, 10U: 879.3±159 a, 20R: 795.0±219 ab, 20U 852.3±227 ab, 60R: 772.7±162 b, 60U: 704.0±235 b. The increase of the surface conditioning time of the lithium disilicate based ceramic increased the surface roughness, showed no significant difference of the bond strength of 20s to 60s, and showed slight decrease to the compressive strength.
34

Efeito da neutralização do ácido fluorídrico, limpeza sônica dos precipitados e da cimentação sobre a resistência à flexão de uma cerâmica vítrea /

Saavedra, Guilherme de Siqueira Ferreira Anzaloni. January 2008 (has links)
Resumo: O objetivo deste trabalho foi avaliar cinco hipóteses: a) o condicionamento ácido diminui a resistência à flexão de uma cerâmica feldspática; b) a cimentação aumenta os valores de resistência à flexão de uma cerâmica feldspática; c) o processo de neutralização dos precipitados do ácido fluorídrico diminui os valores de resistência à flexão de uma cerâmica feldspática; d) a limpeza sônica (ultra-som) com água deionizada dos precipitados do ácido fluorídrico, formados sobre a superfície cerâmica após o condicionamento ácido, aumenta os valores de resistência à flexão de uma cerâmica feldspática; e) a associação entre o processo de neutralização dos precipitados do ácido fluorídrico e a limpeza sônica melhora a resistência à flexão de uma cerâmica feldspática. Foram confeccionadas 60 barras cerâmicas (20x4x1.2mm) (VM7 VITA Zahnfabrik). Cada barra cerâmica (1face) (exceção G1) foi condicionada (20s) com AF10% (Dentsply), seguida pela lavagem jato ar-água (60s) e secagem. Foram selecionadas aleatoriamente e separadas em 6 grupos(n=10): G1 - Controle (sem tratamento); G2 - condicionamento ácido apenas; G3 - o silano(Porcelain Primer,BISCO) foi aplicado na superfície cerâmica seguido da cimentação resinosa (Rely X ARC/3M); G4 - as barras foram imersas (40s) em solução supersaturada de bicarbonato de sódio, lavadas jato ar-água por (5s) e secas antes da aplicação do silano e cimentação; G5 - limpeza sônica (4min), silano e cimentação; G6 - associação da neutralização e limpeza sônica, seguido da silanização e cimentação. Após armazenagem (água destilada/sete dias a 37ºC), cada conjunto cerâmica/cimento) foi levado ao dispositivo de ensaio, sendo este acoplado em uma máquina de ensaios universal (EMIC) com célula de carga de 10Kgf, velocidade de 1,0mm/min e submetidos ao ensaio mecânico de flexão 3 pontos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this study was to evaluate five hypotheses: a) hydrofluoric acid etching decreases the flexural strength of a feldspathic porcelain; b) cementation increases the flexural strength of a feldspathic porcelain; c) the neutralization process of hydrofluoric acid precipitates decreases the flexural strength of a feldspathic porcelain; d) hydrofluoric acid precipitates cleaning with ultrasonic bath in deionized water, formed on the ceramic surface after acid etching, increases flexural strength values of a feldspathic porcelain; e) the association between the neutralization process of the hydrofluoric acid precipitated and ultrasonic sonic cleaning improves the flexural strength of a feldspathic porcelain. Sixty ceramic bars (20x4x1.2mm) (VM7 VITA Zahnfabrik) were made and each one (1 surface) (except G1) was etched (20s) with HF10% (Dentsply), followed by water spray (60s) and drying. The specimens were randomly divided into 6 groups (n=10): G1 - Control (no treatment); G2 - hydrofluoric acid; G3 - silane(Porcelain Primer,BISCO) was applied on porcelain surface followed adhesive cementation (Rely X ARC/3M); G4 - the bars were immersed on a oversaturated sodium bicarbonate solution (40s), washed by water spray (5s) and drying before silane application and cementation; G5 - ultrasonic cleaning (4min), silane and cementation; G6 - association between neutralization and ultrasonic cleaning, followed by silanization and cementation. After storage (distillated water/ 7 days at 37ºC), each set (ceramic/cement) was carry to test device, which was mounted in universal test machine (EMIC) with a load cell of 10 Kgf, crosshead speed of 1,0mm/min, and submitted to the three-point bending mechanical test (immersed on water at 37 ºC). The flexural strength values and standard deviation (MPa) of the groups were: G1: 73,79±5,83a; G2: 60,65±10,07b; G3: 85,10±12,40a; G4: 80,91± ... (Complete abstract click electronic access below) / Orientador: Estevão Tomomitsu Kimpara / Coorientador: Tarcísio José de Arruda Paes Junior / Banca: Eduardo Piza Pellizzer / Banca: Maximiliano Piero Neisser / Banca: Rander Pereira Avelar / Banca: Rubens Nisie Tango / Doutor
35

Efeito da neutralização do ácido fluorídrico, limpeza sônica dos precipitados e da cimentação sobre a resistência à flexão de uma cerâmica vítrea

Saavedra, Guilherme de Siqueira Ferreira Anzaloni [UNESP] 11 December 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-12-11Bitstream added on 2014-06-13T19:05:09Z : No. of bitstreams: 1 saavedra_gsfa_dr_sjc.pdf: 1086992 bytes, checksum: 75c209bde5e5e11f3fb1185fe635e9ab (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar cinco hipóteses: a) o condicionamento ácido diminui a resistência à flexão de uma cerâmica feldspática; b) a cimentação aumenta os valores de resistência à flexão de uma cerâmica feldspática; c) o processo de neutralização dos precipitados do ácido fluorídrico diminui os valores de resistência à flexão de uma cerâmica feldspática; d) a limpeza sônica (ultra-som) com água deionizada dos precipitados do ácido fluorídrico, formados sobre a superfície cerâmica após o condicionamento ácido, aumenta os valores de resistência à flexão de uma cerâmica feldspática; e) a associação entre o processo de neutralização dos precipitados do ácido fluorídrico e a limpeza sônica melhora a resistência à flexão de uma cerâmica feldspática. Foram confeccionadas 60 barras cerâmicas (20x4x1.2mm) (VM7 VITA Zahnfabrik). Cada barra cerâmica (1face) (exceção G1) foi condicionada (20s) com AF10% (Dentsply), seguida pela lavagem jato ar-água (60s) e secagem. Foram selecionadas aleatoriamente e separadas em 6 grupos(n=10): G1 - Controle (sem tratamento); G2 - condicionamento ácido apenas; G3 – o silano(Porcelain Primer,BISCO) foi aplicado na superfície cerâmica seguido da cimentação resinosa (Rely X ARC/3M); G4 – as barras foram imersas (40s) em solução supersaturada de bicarbonato de sódio, lavadas jato ar-água por (5s) e secas antes da aplicação do silano e cimentação; G5 - limpeza sônica (4min), silano e cimentação; G6 - associação da neutralização e limpeza sônica, seguido da silanização e cimentação. Após armazenagem (água destilada/sete dias a 37ºC), cada conjunto cerâmica/cimento) foi levado ao dispositivo de ensaio, sendo este acoplado em uma máquina de ensaios universal (EMIC) com célula de carga de 10Kgf, velocidade de 1,0mm/min e submetidos ao ensaio mecânico de flexão 3 pontos... / The purpose of this study was to evaluate five hypotheses: a) hydrofluoric acid etching decreases the flexural strength of a feldspathic porcelain; b) cementation increases the flexural strength of a feldspathic porcelain; c) the neutralization process of hydrofluoric acid precipitates decreases the flexural strength of a feldspathic porcelain; d) hydrofluoric acid precipitates cleaning with ultrasonic bath in deionized water, formed on the ceramic surface after acid etching, increases flexural strength values of a feldspathic porcelain; e) the association between the neutralization process of the hydrofluoric acid precipitated and ultrasonic sonic cleaning improves the flexural strength of a feldspathic porcelain. Sixty ceramic bars (20x4x1.2mm) (VM7 VITA Zahnfabrik) were made and each one (1 surface) (except G1) was etched (20s) with HF10% (Dentsply), followed by water spray (60s) and drying. The specimens were randomly divided into 6 groups (n=10): G1 - Control (no treatment); G2 – hydrofluoric acid; G3 – silane(Porcelain Primer,BISCO) was applied on porcelain surface followed adhesive cementation (Rely X ARC/3M); G4 – the bars were immersed on a oversaturated sodium bicarbonate solution (40s), washed by water spray (5s) and drying before silane application and cementation; G5 – ultrasonic cleaning (4min), silane and cementation; G6 – association between neutralization and ultrasonic cleaning, followed by silanization and cementation. After storage (distillated water/ 7 days at 37ºC), each set (ceramic/cement) was carry to test device, which was mounted in universal test machine (EMIC) with a load cell of 10 Kgf, crosshead speed of 1,0mm/min, and submitted to the three-point bending mechanical test (immersed on water at 37 ºC). The flexural strength values and standard deviation (MPa) of the groups were: G1: 73,79±5,83a; G2: 60,65±10,07b; G3: 85,10±12,40a; G4: 80,91± ... (Complete abstract click electronic access below)
36

EFEITO DO CONDICIONAMENTO COM DIFERENTES CONCENTRAÇÕES DE ÁCIDO FLUORÍDRICO NA ADESÃO E NA RESISTÊNCIA À FLEXÃO DE UMA CERÂMICA FELDSPÁTICA / EFFECT OF ETCHING WITH DIFFERENT CONCENTRATIONS OF HYDROFLUORIC ACID ON THE ADHESION AND THE FLEXURAL STRENGTH OF A FELDSPATHIC CERAMIC

Venturini, Andressa Borin 06 August 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Purpose: To evaluate the effect of different hydrofluoric (HF) acid concentrations in the contact angle and in the durability of bond strength between feldspathic ceramic and resin cement, as well as the impact on the roughness and flexural strength of this ceramic. Materials and Methods: Twenty-five ceramic blocks (VitaBlocks Mark II) (12 x 10 x 2.4 mm) were produced for contact angle analysis, 40 ceramic blocks (12 x 10 x 4 mm) for microtensile bond strength (MTBS), and 150 ceramic barshaped specimens (14 x 4 x 1.2 mm) to evaluate the roughness and flexural strength. Specimens were randomly divided into 5 groups, excluding the control group for MTBS: SC (control) - no ceramic surface treatment; etching with HF acid 1% (HF1), 3% (HF3), 5% (HF5) and 10% (HF10) for 60. The contact angle measurements were performed on a Goniometer and the MTBS test in a universal testing machine. All bar-shaped specimens were analyzed in a profilometry and loaded to failure using a 3-point bending test. Data were submitted to statistical analysis. Results: SC had the highest contact angle (61.4°± 5°), whereas HF10 showed the lowest value (17.5° ± 4°). In dry conditions, different HF acid concentrations promoted similar bond strength statistically (14.2 to 15.7 MPa) (p<0.05), but when the specimens were aged, only the bond from the HF1 group decreased statistically (14.5 to 10.2 MPa). All groups produced significantly rougher surfaces than the control group (SC) (p<0.05). However, the mean flexural strength values were not statistically different among the etched groups (106.47 to 102.02 MPa). Conclusion: In terms of adhesion, the tested ceramic can be etched with HF acid in concentrations of 3%, 5% and 10%. Different acid concentrations did not affect the flexural strength of the tested ceramic. Acid etching appear to have a weakening effect on the ceramic surface, if compared to the untreated group. / Objetivo: Avaliar o efeito de diferentes concentrações de ácido fluorídrico (HF) no ângulo de contato e na durabilidade da resistência adesiva entre uma cerâmica feldspática e um cimento resinoso, bem como o impacto sobre a rugosidade e resistência à flexão desta cerâmica. Materiais e Métodos: Vinte e cinco blocos cerâmicos (VitaBlocks Mark II) (12 x 10 x 2.4 mm) foram produzidos para a análise do ângulo de contato, 40 blocos cerâmicos (12 x 10 x 4 mm) para resistência de união à microtração (MTBS) e 150 espécimes em forma de barra de cerâmica (14 x 4 x 1,2 mm) para avaliar rugosidade e resistência à flexão. Os espécimes foram divididos aleatoriamente em 5 grupos, excluindo o grupo controle para MTBS: SC (controle) - sem tratamento da superfície cerâmica; condicionamento com ácido HF 1% (HF1), 3% (HF3), 5% (HF5) ou 10% (HF10) por 60 s. As medidas de ângulo de contato foram realizadas no Goniômetro e o teste MTBS em uma máquina de ensaio universal, sendo metade dos espécimes de cada bloco testados imediatamente e a outra metade submetida à armazenagem/termociclagem. Todas as amostras em forma de barra foram analisadas em um rugosímetro e carregadas até a falha usando um teste de flexão de três pontos. Os dados foram submetidos à análise estatística. Resultados: SC obteve o maior ângulo de contato (61,4° ± 5°), enquanto que HF10 apresentou o menor valor (17,5° ± 4°). Em condições secas, diferentes concentrações de ácido HF promoveram resistências adesivas estatisticamente semelhantes (14,2-15,7 MPa) (p<0,05), mas quando os espécimes foram envelhecidos, apenas a adesão do grupo HF1 reduziu estatisticamente (14,5-10,2 MPa). Todos os grupos produziram superfícies significativamente mais rugosas do que o grupo controle (SC) (p<0,05). No entanto, os valores médios de resistência à flexão não foram estatisticamente diferentes entre os grupos condicionados (106,47- 102,02 MPa). Conclusão: Em termos de adesão, a cerâmica testada pode ser condicionada com ácido HF em concentrações de 3%, 5% ou 10%. As diferentes concentrações de ácido não afetaram a resistência à flexão da cerâmica testada. O condicionamento ácido parece ter um efeito de enfraquecimento sobre a superfície cerâmica, se comparado com o grupo não tratado.
37

Projeto, montagem e caracterizacao de um sensor de fluor com eletrolito solido ceramico de PbFsub2

PORTELLA, KLEBER F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:42Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:12Z (GMT). No. of bitstreams: 1 05232.pdf: 6473842 bytes, checksum: 88d593005dc2c79ae422916e7fcaf0d9 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
38

Analise de perigos em uma instalacao de producao de hexafluoreto de uranio

MARIN, MARISTHELA P. de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:50Z (GMT). No. of bitstreams: 1 06758.pdf: 7509221 bytes, checksum: 45da3728e2c97a96f5ffba7532d43826 (MD5) / Dissertacao [Mestrado] / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
39

Projeto, montagem e caracterizacao de um sensor de fluor com eletrolito solido ceramico de PbFsub2

PORTELLA, KLEBER F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:42Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:02:12Z (GMT). No. of bitstreams: 1 05232.pdf: 6473842 bytes, checksum: 88d593005dc2c79ae422916e7fcaf0d9 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
40

Analise de perigos em uma instalacao de producao de hexafluoreto de uranio

MARIN, MARISTHELA P. de A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:50Z (GMT). No. of bitstreams: 1 06758.pdf: 7509221 bytes, checksum: 45da3728e2c97a96f5ffba7532d43826 (MD5) / Dissertacao [Mestrado] / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.0664 seconds