• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Technology and Energy Inventory of Ice Rinks

Makhnatch, Pavel January 2011 (has links)
Currently 341 ice rinks are in operation in Sweden with an estimated total energy consumption of 384 GWh/year. As it has been revealed in previous studies, most of the ice arenas are constructed and/or not operated efficiently. Thus it is considerable energy saving potential, which could be achieved in this area. The potential is even more significant if one can consider the savings in the ice rinks all over the world. This report is an in-depth study, which aims at analysing the Swedish ice rinks energy consumption and estimation of the corresponding energy saving potential. The report analyses the energy statistics obtained through the Stoppsladd study, which includes the ice rinks inventory, data collection and compilation of energy relevant data for 100 ice rinks located in Sweden. The inventory has revealed a number of important statistical figures, such as total energy consumption average in total (estimated to be 1,137 MWh/year) and for different ice arenas categories in particular. Relevant specific energy consumption values as well as a number of other important figures are also provided in the paper, thus giving an idea on the way to minimise energy consumption at each specific ice rink. The results are additionally supported by statistical multifactor regression analysis, which resulted in a relation between the ice rink’s total energy consumption and some known factors values affecting it. Two in-depth studies fulfil the Stoppsladd project by analysing water quality and ice quality effect on the ice rink’s energy consumption and investigation of the static and dynamic heat flow distribution in ice rink slab. A static heat flow distribution model of an ice rink evaluated the effect of concrete  with different properties on temperature and heat flow distribution within an ice rink floor slab. The study proves that the ice rink refrigeration system COP2 could be increased with 3.5 % just implementing new high thermal conductivity concrete layer into the conventional concrete ice rink floor. The static analysis results were further completed with dynamic analysis, which adequately reflects the thermodynamic response of the concrete ice rink floor to a varying heat load. As a result, the thesis represents a holistic approach to the ice rink energy efficiency increase problem and provides a good basis for further studies in relevant areas. It is proved that modified concrete allowing higher (efficient) secondary refrigerant tempera­tures and also provides better response to change in heat load to the system. / Stoppslad
2

Klimatförhållanden och energianvändning på Gränby ishall : Hur Uppsala kommun Arenor och fastigheter AB kan förbättra klimatförhållandena och sänka energianvändningen i Gränby ishall

Kylhed, Ebba January 2024 (has links)
This report intends to investigate climate conditions and energy consumption in Gränby Ice rink in Uppsala.Today, Gränbyhallen faces a potential renovation project to modernize and improve what was initially intended as a temporary hall that was inaugurated in 1974.In 2021, the property was taken over by the Uppsala municipality Arenor och Fastigheter AB from having previously been owned by the municipality. Since then, Arenor och Fastigheter has worked to modernize its facilities and in this way also work to improve the energy consumption required by the operation of the Gränby ice rink and also examine the indoor climate conditions in the building.The idea is to make the climate more pleasant for the visitors, and therefore making it less cold and barren temperaturevise by separating the ventilation from the ice and bleachers so that these can be controlled individually. The hope is to be able to reduce energy consumption with such a solution by seeing if the facility has heat leakage from the outside and how moisture can be managed in the facility to be kept at a more even level throughout the year and during the day.For the report, weather data was obtained from SMHI and then compiled and compared with temperatures and energy consumption from sorption dehumidifiers and the plant total to locate current deficiencies but also how to potentially address these to lower energy consumption.Analysis of the data was also done for the outdoor temperature which was set against the indoor temperature and then also the difference between the two to see the difference anddemonstrate how well insulated the facility is. On average over the entire time investigated, there was only +1°C difference between outside and inside, which gives an indication that the insulation in the facility needs to be reviewed and improved both outside and inside as there are large leaks in the facility with open surfaces and only metal doors that separate warm surfaces from cold.The analysis also suggests that the dehumidifier should be changed to regulate according to the dew point temperature from regulating according to the relative humidity as the dew point changes less over time and is less affected by the amount of water in the air which changes from hour to hour and is also affected by the outdoor climate when doors are opened and closed to the facility. / Denna rapport avser att undersöka klimatförhållanden och energiförbrukningen i Gränby ishall i Uppsala. Idag står Gränbyhallen inför ett potentiellt renoveringsarbete för att modernisera och förbättra till en som till en början var tänkt som en provisorisk hall från 1974. 2021 togs fastigheten över av Uppsala kommun Arenor och Fastigheter AB från att tidigare varit kommunägt. Arenor och Fastigheter har sedan dess arbetat med att modernisera sina fastigheter och på så sätt även arbeta med att förbättra energiförbrukningen som driften i Gränby ishall kräver och även undersöka klimatförhållandena inomhus. Tanken är att göra klimatet för åskådarna mer behagligt att vistas i från dagens kalla och karga temperaturer genom att separera läktarens ventilation och avfuktning från isens, så att dessa kan styras enskilt och därmed ha olika klimat. Förhoppningen är att med en sådan lösning kunna minska energiförbrukningen genom att se ifall anläggningen har värmeläckage från utsidan samt hur fukt kan hanteras i anläggningen för att hållas på en mer jämn nivå över året och under dagen. Till rapporten har väderdata hämtats från SMHI och sedan sammanställts och jämförts med temperaturer och energiförbrukning från sorptionsavfuktare och anläggningens total för att lokalisera nuvarande brister, men även hur man kan potentiellt åtgärda dessa för att sänka energiförbrukningen. Analys av data gjordes även för temperaturen utomhus mot temperaturen inomhus och då differensen av de två för att se skillnaden och påvisa även hur väl isolerad anläggningen är. I genomsnitt över hela tiden som undersöktes skildes det bara +1°C mellan ute och inne, vilket ger indikation på att isoleringen i anläggningen behöver ses över och förbättras både ute och inne då det finns stora läckage i anläggningen med öppna ytor och endast plåtdörrar som separerar varma ytor från kalla. Analysen tyder även på att avfuktaren bör ändras till att reglera efter daggpunktstemperaturen i stället för som nu efter relativa luftfuktigheten. Daggpunkten ändras mindre över tid och påverkas mindre av luftens vattenmängd, som ändras från timme till timme och som påverkas även av utomhusklimatet när dörrar öppnas och stängs till anläggningen.

Page generated in 0.0464 seconds