• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 189
  • Tagged with
  • 191
  • 191
  • 165
  • 83
  • 56
  • 53
  • 51
  • 50
  • 34
  • 31
  • 27
  • 27
  • 26
  • 24
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Análises biomecânica e histológica da interface de implantes osseointegrados submetidos à carga mastigatória imediata em mandíbulas de cães

Lenharo, Ariel [UNESP] 03 November 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-11-03Bitstream added on 2014-06-13T19:22:06Z : No. of bitstreams: 1 lenharo_a_dr_araca_prot.pdf: 1956702 bytes, checksum: 5122f32b3aab14c8107085fded1a11c7 (MD5) / O objetivo deste trabalho foi de estudar em mandíbula de cães, os implantes osseointegrados submetidos a carga imediata considerando a qualidade óssea formada na interface implante-osso, como também medir o contato ósseo da referida interface. Foram utilizados quatro cães que, após as exodontias, receberam três implantes Osseotite 3,75 x 8,5 (Implant Innovations Incorporation) e, após os procedimentos de moldagem e de laboratório para a confecção da prótese em Níquel-Cromo, estas foram instaladas no mesmo dia da instalação dos implantes e submetidas a técnica da carga imediata. Após 240 dias, os implantes mesial e distal foram contra-torqueados medindo-se a resistência do tecido ósseo neoformado. Na seqüência, os animais foram sacrificados (240 dias) e as peças foram processadas para cortes histológicos sem descalcificação. As lâminas obtidas foram coradas pelo azul de toluidina e pelo picro-sirius que foram analisadas pelos microscópios óptico e de luz polarizada, respectivamente. Nas lâminas coradas pelo azul de toluidina, foi possível observar o tecido ósseo neoformado em contato com a superfície dos implantes com ósteons bem definidos. Nestas lâminas foram medidos os perímetros dos implantes para determinar o contato ósseo. As lâminas coradas pelo picro-sirius mostraram deposição de colágeno tipo I. A média de contato ósseo foi de 77,5% e o teste de contratorque aplicado nos implantes apresentou média de 76,13 Ncm. Considerando as limitações deste trabalho, foi possível concluir que a carga imediata em segmentos parcialmente desdentados é uma técnica viável para reabilitação bucal. / The objective of this work was to study the osseointegrated implants undergone immediately loading in dog mandibles, considering the bone quality formed in the implant-bone interface as well as bone contact. Four dogs were used, which after exodontics, received three Osseotite implants 3.75 x 8.5 (Implant Innovations Incorporation) and after the full-arch impression with custom tray and laboratorial procedures for the fabrication of the prosthesis in nickel chrome, this one were installed in the same day as the installation of the implants and was undergone a immediately loading. After 240 days, the mesial and distal implants were reverse torqued, measuring like this, the resistance of the neoformed osseous tissue. Soon after, the animals were sacrificed (240 days) and the samples were processed for histological examination by means of undescalcified sections without decalcification. The histologic specimens attained were stained with toluidine blue and with Picrus Sirius. After microscopical examination of the sections stained by toluidine blue with the optical microscope, it was possible to observe the neoformed osseous tissue and with the presence of well defined osteons. The histologic specimens stained with Picrus Sirius were analysed by polarized light microscope and they showed type I collagen deposition. The mean of osseous contact was of 77.5% between the implant and the bone, and the biomechanical test by means of reverse-torque presented a mean of 76.13 Ncm. Considering the limitations of this work it was possible to conclude that the immediately loading in partially edentulous segments is a viable technique for oral rehabilitation.
72

Estudo da influência de corticóides no processo inicial de osseointegração de implantes de titânio instalados em maxilas de ratos

Oliveira, Sérgio Ricardo de [UNESP] 12 February 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:27Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-02-12Bitstream added on 2014-06-13T21:06:12Z : No. of bitstreams: 1 oliveira_sr_dr_araca.pdf: 4808815 bytes, checksum: 6fc8deeffcd2c27c59c5d08cd94ab969 (MD5) / As modalidades terapêuticas que envolvem implantes dentais têm se expandido gradativamente, sendo implantados em uma variedade de estruturas ósseas. Dessa forma, o propósito do presente trabalho foi estudar a influência de corticóides no processo inicial de osseointegração de implantes de titânio instalados em maxilas de ratos. Foram utilizados implantes de titânio c.p., grau II, cônico de 1,4mm de diâmetro e 2,7mm de comprimento, com superfície tratada. Trinta e oito ratos wistar tiveram seus primeiros molares superiores esquerdo e direito extraídos. Após 30 dias de reparo alveolar, dois animais foram sacrificados para confirmar o fim desse processo. Os demais animais tiveram os implantes instalados bilateralmente e foram divididos randomicamente em três grupos: Controle (Ctr/n=12) que não receberam nenhum tipo de tratamento; Placebo (Pl/n=12) e Tratado (Tra/n=12), que receberam injeções diárias de 1 ml de solução salina e corticosterona na dosagem de 5mg/kg, respectivamente. Trinta dias após a implantação, todos os animais foram eutanasiados e tiveram a concentração plasmática do corticóide mensurada: Ctr (101,31 ± 26,7 ng/ml), Pla (95,22 ± 25,36 ng/ml) e Tra (281,37 ± 64,72 ng/ml); e o contato osso-implante determinado: Ctr (96,67%), Pla (82,22%) e Tra (15,73%), nos quais o grupo Tra apresentou-se estatisticamente diferente dos demais grupos (p<0,05). Assim, diante da metodologia empregada, foram evidenciadas menor formação óssea e conseqüente redução da área de tecido ósseo neo-formado na interface osso-implante. / The therapeutic modalities which involves dental implants has been gradually expanded, being implanted in a variety of bone structures. In this way, the aim of the present work was to study the corticoid influence at the initial process of bone integration of titanium implants installed in rat jaws. It were used titanium implants c.p.; grade II, conic with 1,4mm diameter and 2,7mm length, with treated surface. Thirty eight wistar rats had their first upper left and right molars extracted. After 30 days of alveolar repair, two animals were sacrificed to confirm the end of this process. The others had their implants installed bilaterally and they were splited randomly in three groups: Control (Ctr/n=12) which did not receive any kind of treatment; Placebo (Pla/n=12) and Treated (Tre/n=12) which received 1ml daily shots of salt solution and corticosterone at a dosage of 5mg/Kg, respectively. Thirty days after the implantation, all the animals were euthanasiated and the plasmatic concentration of corticoid was measured: Ctr (101,31 ± 26,7 ng/ml), Pla (95,22 ± 25,36 ng/ml) and Tre (281,37 ± 64,72 ng/ml); and the bone implant contact was determined: Ctr (96,67%), Pla (82,22%) and Tre (15,73%), in which the Tre group presented statistically different from the other groups (p<0,05). Thus, front the employed methodology it was shown lesser bone formation and consequent reduction of the bone tissue area neo-formed at bone-implant interface.
73

Influência do Diabetes mellitus e da insulinoterapia sobre a osseointegração: avaliação histométrica em coelhos

Margonar, Rogério [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T21:06:11Z : No. of bitstreams: 1 margonar_r_dr_arafo.pdf: 636857 bytes, checksum: a2ff7c5e1668a51d2ac5f3e8e722334f (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A indicação de implantes dentais osseointegráveis para pacientes com comprometimento sistêmico como o Diabetes Mellitus permanece controversa. O objetivo deste estudo foi avaliar, por meio de parâmetros histométricos, a influência do Diabetes Mellitus e da insulinoterapia sobre a osseointegração. Foram utilizados 34 coelhos adultos da raça Nova Zelândia, os quais foram divididos nos seguintes grupos: grupo controle (C), grupo diabético induzido (D) e grupo diabético tratado com insulina (DTI). A indução do diabetes foi realizada por administração de Aloxana (115 mg/kg). Os coelhos do grupo DTI receberam tratamento com injeção subcutânea de insulina (10 U/ dia) e os demais receberam solução salina (0,9%) pela mesma via. Cada animal recebeu dois implantes para análise histométrica. Após 4, 8 e 12 semanas, os animais foram sacrificados e as peças reduzidas para processamento histológico. Os três grupos não apresentaram diferenças em relação a área óssea (AO). Entretanto, o Grupo C apresentou maior extensão de contato osso/implante (ECOI) nos três períodos experimentais P<0,001 e os Grupos D e DTI não mostraram diferenças estatística em relação a ECOI P= 0,75. Assim, pode-se concluir que o Diabettes Mellitus influenciou negativamente a osseointegração de implantes colocados em tíbias de coelhos e a insulinoterapia não alterou este efeito. / The indication for the placement of osseointegrated dental implants in patients with systemic illness, like diabetes, remains controversial. The purpose of this study was to evaluate, through the histrometric parameters , the influence of Diabetes Mellitus and its treatment with insulin, on osseointegration around implants. Thirty four New Zealand adult rabbits were separated in 3 groups: control group (C), diabetes group (D) and insulin treatment diabetes group (DTI). Aloxana (115mg/kg) was used in diabetes induction. The DTI group received treatment with insulin (10 U/ day) and the others received saline solution (0,9%). After 1 week, implants were placed bilaterally in the tibiae of rabbits. After 4, 8 and 12 weeks, the animals were sacrificed and the implants were analyzed. The bone area didn'tþ show statistically greater values to the D, C e DTI groups. The C group showed statistically greater values bone contact with the surface implant than D and DTI groups in all periods (p<0,001). The groups D and DTI didn't showed any significant differences between each other in any period evaluated for bone implant contact (p=0,765). Thus, it may be concluded that Diabettes Mellitus can negatively influence the osseointegration around implants in tibiae of rabbits and insulin therapy did not altered this effect.
74

Avaliação tridensional da precisão das técnicas de moldagem para próteses implantossuportadas sobre pilares alinhados e não-alinhados

Munhoz Cháves, Alejandro [UNESP] 17 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-17Bitstream added on 2014-06-13T21:06:54Z : No. of bitstreams: 1 munozchavez_a_dr_arafo.pdf: 2735655 bytes, checksum: 57a4aa3a7ba468631481a08da1143c06 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão tridimensional das moldagens para próteses sobre implantes, utilizando-se a técnica direta, variando-se os transferentes (transferentes quadrados, transferentes quadrados com extensão vestíbulo-lingual, transferentes quadrados unidos com Duralay, transferentes quadrados unidos com barra de metal e Index), o tipo de material de moldagem (Impregum Soft média viscosidade, Express consistência regular - 3M ESPE) e a disposição dos implantes (alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Foi obtido um total de cinqüenta e seis modelos, sendo sete por técnica, mais sete registros do index. Estas medições tridimensionais foram feitas por um programa (ReflexSoft 1.0) que recebia as imagens StereoMicroscópio Reflex. Os valores de distorção médios obtidos foram: Index = 25,88μm (±3,41 SD); Quadrado/ Impregum = 80,22μm (±6,36 SD); Quadrado/ Express = 80,72 μm (±4,92 SD); Quadrado Duralay/Impregum = 84,63 μm (±9,22 SD); Quadrado Duralay/ Express =78,73 μm (±6,84 SD); Quadrado hélice/ Impregum = 30,72 μm (±3,53 SD); Quadrado Hélice/ Express = 30,21 μm (±4,08 SD); Quadrado Barra Metálica/Impregum = 57,08 μm (±5,96 SD); Quadrado Barra Metálica/ Express = 50,77 μm (±4,82 SD). Os testes estatísticos utilizados foram Holm-Sidak Method e Mann-Whitney (a=0,05). Pode-se concluir que em relação às técnicas estudadas que:... / An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas. Nine groups were formed: (Index(I); squared impression copings/ Impregum (SI), metal splinted Impression copings/ Impregum (MI), Duralay splinted impression copings/Impregum (DI), Squared modified Impression copings/ Impregum (SMI), squared impression copings/ Express (SE), metal splinted Impression copings/ Express (ME), Duralay splinted impression copings/ Express (DE) and Squared modified Impression copings/ Express (SME) with 7 casts each were formed,. The measurements were analyzed using software that received the images of a video camera coupled Reflex microscope. Data were analyzed with a 1-way analysis of variance at α <.05, followed by the Holm-Sidak Method and Mann-Whitney test (α <.05). Results. The mean values of abutment/framework interface gaps were: I group 25,88μm (±3,41 SD); SI group 80,22μm (±6,36 SD); SE group 80,71μm (±4,92 SD); MI group 57,07μm (±5,96 SD); ME group 50,76μm (±4,82 SD); DI group 84,63μm (±9,22 SD); DE group 78,73μm (±6,84 SD); HI group 30,71μm (±3,53 SD); HE group 30,21μm (±4,08 SD). No significant difference was detected between I group and HI group, and between I group and HE group (P <.05). Did not exist superiority regarding the impression material.
75

Precisão das técnicas de moldagem para próteses implantossuportadas

Del'Acqua, Marcelo Antonialli [UNESP] 08 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-08Bitstream added on 2014-06-13T21:07:01Z : No. of bitstreams: 1 delacqua_ma_dr_arafo.pdf: 1398989 bytes, checksum: 17374b239dcb2b543aaaa9731517a5ca (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Desde que não há consenso em relação a técnica de moldagem mais precisa, foi objetivo deste estudo in vitro avaliar a precisão de 1 técnica de registro (Index de resina composta) e de 5 técnicas de moldagem para próteses implantossuportadas (transferentes quadrados, quadrados jateados, quadrados com extensão lateral, quadrados unidos com Duralay e quadrados unidos com barra de metal) empregando-se 3 materiais de moldagem: silicone de polimerização por adição consistência densa/fluida com moldeira de estoque de inox, poliéter média viscosidade e silicone de polimerização por adição consistência regular com moldeira individual. Foram construídos 1 modelo mestre com 4 análogos de pilares Micro-Unit e 1 estrutura metálica. Obteve-se do modelo mestre um total de 45 modelos, sendo 5 por técnica. A estrutura metálica foi parafusada utilizando-se a técnica de mensuração de fendas por um parafuso. Estas medições foram feitas com o auxílio do programa Leica QWin que recebeu as imagens de uma câmara de vídeo acoplada a uma lupa com um aumento de 100 x. Os resultados obtidos foram analisados estatisticamente utilizando o teste de Kruskal-Wallis seguido pelo método de Dunn, !=0,05. Dentro das condições experimentais deste estudo, podese concluir que não houve diferença estatística entre: modelo mestre (31,63 !m), quadrado Impregum (38,03 μm), quadrado jateado Impregum (46,80 μm), Index (45,25 μm) e quadrado com extensão lateral Express consistência densa/fluida (51,20 μm), sendo esta a eleita. Devido aos piores resultados obtidos com as técnicas quadrado Express regular (151,21 μm) e quadrado jateado Express regular (136,59 μm), o material de moldagem Express consistência regular não deve ser empregado, sendo escolhido então para ser utilizado com moldeiras individuais o Impregum viscosidade média. Caso o cirurgião-dentista pretenda realizar... / Since there is still no consensus regarding the most accurate impression techniques, it was the purpose of this study compared the dimensional accuracy of stone index and of 5 impression techniques for implant-supported prostheses (squared impression copings, modified squared, !squared sandblasted and coated with impression adhesive, modified squared, Duralay splinted and metal splinted) using 3 impression materials: vinyl polysiloxane putty/light body with a metal stock tray and polyether medium consistency and vinyl polysiloxane regular body were used with a custom aluminum tray. A master cast with 4 parallel implant abutment analogs and a framework were fabricated. Nine groups (n=5) were tested. The gap measurement method employed was just one titanium screw tightened to the framework. Group’s measurements were analyzed using LeicaQWin software that received the images of a video camera coupled to a stereomicroscope at x100 magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, !=.05. Under the conditions of this study the following conclusions could be drawn: no significant difference was detected among Master Cast (31.63 !m), Squared Impregum (38.03 !m), Sandblasted-Adhesive Squared Impregum (46.80 !m), Index (45.25 μm) and Modified Squared techniques (51.20 μm) (P=.05), being the elected. Due to the worst results with the techniques Squared Express Regular (151.21 μm) and Sandblasted-Adhesive Squared Express Regular (136.59 μm), the Express regular body impression material should not be used, and then chosen to be used Impregum Soft medium consistency with custom tray. If the dentist wishes to perform the technique with splinted copings (Metal Splinted = 68.55 !m and Duralay Splinted = 165.03 !m), the splint should be made with bars of metal. The impression technique using sandblasted-adhesive squared... (Complete abstract click electronic access below)
76

Extensometria: avaliação de implantes de sextavado externo posicionados na configuração linear e compensada (offset), sob carregamento axial

Kojima, Alberto Noriyuki [UNESP] 07 July 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-07Bitstream added on 2014-06-13T20:25:48Z : No. of bitstreams: 1 kojima_an_dr_sjc.pdf: 500670 bytes, checksum: 06c2a32f2d0fe96b743e1f05b9e95270 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste estudo foi avaliar, por meio da extensometria, a distribuição de tensões ao redor de implantes em função dos diferentes locais para carregamento, tipo de coifa (plástica ou usinada) e configuração (linear e compensada). Para tanto, em um bloco de poliuretano, foram posicionados paralelos entre si e com uma configuração linear, implantes auto-rosqueáveis de hexágono externo, com dimensões de 3,75 X 13mm, a uma distancia de 7mm, de centro a centro. Em um outro bloco a fixação do meio foi deslocada em 2mm para gerar uma configuração compensada (offset). Pilares protéticos Micro-unit, com 3mm de cinta foram instalados sobre as fixações. Com duas matrizes em aço inoxidável foram confeccionados 10 enceramentos para cada bloco, distribuídos da seguinte forma: 5 para coifa plástica e 5 para coifas usinadas (n=5). A seguir esses padrões foram fundidos com uma liga de Co-Cr. Quatro extensômetros (strain gauges) foram colados na superfície superior de cada bloco tangenciando a plataforma de cada fixação. Um carregamento de 30kg durante 10s foi feito em cinco posições (A, B, C, D, E), sendo repetido três vezes para aquisição dos dados (em με) pela aparelho condicionador de sinais. Os dados obtidos foram submetidos a análise de variância (ANOVA) e teste de Tukey (p<0,05). Como conclusão da análise dos resultados obtidos pudemos observar que não houve diferença na utilização de coifas plásticas e usinadas, que não houve diferença entre as configurações linear e compensada; havendo diferença estatisticamente significante para os locais de carregamento / The aim of this study was to evaluate, using strain gauge, the load distribution surround the implants according differents loading sites, coping types (plastic and machined) and configuration (linear and offset). In one polyurethane block, three cylindrical implants with external hexagon (3.75mm x 13mm) were fixed parallel with 7mm between their centers in a linear configuration. In another block the midle implant was positioned in a 2mm offset. Micro-units abutments with 3mm of metallic neck were fixed. With two metallics matrix, it was manufactured 10 wax patterns for each block, distributed in the following form: 5 for plastic copings and 5 for machined copings (n=5). After, patterns were casted in cobalt-chromium alloy. Four strain gauges were positioned on the upper surface of each polyurethane model around the implants. An axial load of 30kg within 10 seconds in five positions (A, B, C, D, E), with three repetead measurements for data aquisition (in με) by the multichanel bridge machine. The datas were submitted to ANOVA and Tukey test (p<0.05). Such as conclusion from the obtained data treatment: there was no difference between the plastic and machined copings, there was no difference between the linear and offset configuration; there was statiscal significance only with the differents loading sites.
77

Efeito da dieta com deficiência de magnésio sobre a manutenção da osseointegração de implantes de titânio: análise radiográfica, densitométrica e de torque reverso

Landázuri del Barrio, Ricardo Andrés [UNESP] 31 March 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-03-31Bitstream added on 2014-06-13T18:32:30Z : No. of bitstreams: 1 landazuridelbarrio_ra_me_arafo.pdf: 1042736 bytes, checksum: be0df9361c27ca57464b057d0b3fb500 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A deficiência de magnésio (Mg) na dieta pode ser considerada um fator de risco para o desenvolvimento de osteoporose. A diminuição de Mg na dieta está relacionada à perda de massa óssea em humanos; e em animais, estudos têm demonstrado osteopenia, crescimento ósseo anormal e fragilidade esqueletal. Este estudo avaliou a influência da deficiência de Mg na dieta em ratos jovens e adultos sobre o torque de remoção de implantes e sobre a densidade óssea e radiográfica ao redor de implantes osseointegrados instalados na tíbia dos ratos. Noventa ratos Holtzman foram separados em 2 grupos (n=45; 180 gr - animais jovens/ n=45; 360 gr - animais adultos); cada animal recebeu um implante em cada metáfise tibial. Após a osseointegração dos implantes (60 dias), os dois grupos de animais foram sub-divididos em três grupos: grupo Controle (CTRL, n=15), grupo de deficiência de Mg de 75% (Mg1; n=15) e grupo de deficiência de Mg de 90% (Mg2; n=15). Após 150 dias da instalação dos implantes, todos os animais foram sacrificados. Foram coletadas amostras de sangue e urina, realizada a densitometria óssea das vértebras lombares (L2, L3 e L4) e do fêmur, realizada a densidade óssea radiográfica e mensuração da espessura da cortical óssea, além do teste biomecânico de torque de remoção dos implantes. A análise densitométrica (vértebras lombares e fêmur) e os valores da concentração plasmática e urinária de Mg confirmaram o comprometimento sistêmico dos animais, mostrando valores menores de densidade óssea para os grupos Mg1 e Mg2. A análise da densidade radiográfica demonstrou alterações no osso cortical e medular dos grupos Mg1 e Mg2. A análise da espessura da cortical óssea demonstrou alterações na espessura do osso cortical, apresentando valores menores nos grupos Mg1 e Mg2. / Low dietary magnesium (Mg) may be a risk factor for osteoporosis. Mg intake has been associated with bone mass loss in humans. Mg deficiency in animal models has showed osteopenia, impaired bone growth and skeletal fragility. This study evaluated the influence of magnesium deficiency on diet in young and adult rats on the removal torque of osseointegrated titanium implants. Ninety male Holtzman rats (n=45; 180 gr - young rats / n=45; 360 gr - adult rats) were divided in two groups and received a titanium implant in the tibia metaphysis. After the healing period of 60 days, the animals were randomly divided in three sub-groups: control group (CTRL, n=15 animals), 75% magnesium deficiency group (Mg1, n=15 animals) and 90% magnesium deficiency group (Mg2, n=15 animals). The dietary magnesium deficiency was induced in two groups (Mg1 and Mg2) for 90 days. After 150 days postimplant placement, all animals were sacrificed and collected samples of blood and urine. Densitometry of femur and lumbar vertebrae was performed by dual-energy x-ray absorptiometry (DXA), bone density was measured by digital radiographs at 6 points on sides of the implant and was performed the measurement of the thickness of the cortical bone. All implants were subjected to removal torque. Densitometric analysis (femur and lumbar vertebrae) and serum and urinary magnesium concentration confirmed a systemic impairment of the animals, showing lower bone mineral density for Mg1 and Mg2 in young and adult rats. The analysis of radiographic bone density revealed a negative impact of the Mg deficiency in the cancellous and cortical bone. Analysis of the thickness of cortical bone showed alterations on cortical bone in Mg1 and Mg2 groups. Analysis of the removal torque of the implants in young rats showed a decrease of the removal torque for the Mg1 and Mg2 groups (P <0.05) with a statistical difference in relation to the CTRL group.
78

Análise histológica de defeitos ósseos preenchidos com biomateriais e associados a implantes osseointegrados. Estudo em cães

Mantovani Junior, Milton [UNESP] 30 August 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-08-30Bitstream added on 2014-06-13T18:57:05Z : No. of bitstreams: 1 mantovanijunior_m_me_arafo.pdf: 634426 bytes, checksum: 7c036072741d3c862dd36b7b87378fd5 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / O objetivo deste estudo foi avaliar histologicamente o efeito da quitosana e do biovidro colocados em defeitos ósseos críticos criados em mandíbulas de cães e associados a implantes osseointegráveis. Para isso, foram utilizados 8 cães adultos jovens e sem raça definida, que foram submetidos às exodontias dos terceiros e quartos pré-molares inferiores, bilateralmente. Após 12 semanas, nos locais das exodontias, foram instalados 2 implantes de Ticp de 3,3 x 10 mm, e em seguida criados defeitos ósseos cilíndricos com 4 mm de diâmetro por 5 mm de profundidade na região vestibular de cada implante. Os 8 animais foram divididos em 4 grupos, a saber: Grupo I - Controle negativo (Coágulo sanguíneo), Grupo II - Defeito preenchido com osso autógeno, Grupo III - Defeito preenchido com Biovidro e Grupo IV - Defeito preenchido gel de quitosana. Foram realizadas biópsias ósseas aos 15 e aos 90 dias, num total de 4 biópsias por biomaterial/período, que foram processadas e avaliadas através de análise histológica descritiva. Como resultado, observou-se aos 15 dias formação de tecido fibroso no grupo controle, e nos grupos tratados com osso autógeno, quitosana e biovidro, observouse neoformação óssea com padrão denso e espaços medulares preenchidos com tecido fibroso, de forma e tamanhos variáveis, com trabéculas ósseas compactas. Aos 90 dias, observou-se a maturação do osso neoformado nesses três grupos. No grupo III (Biovidro), aos 90 dias observa-se presença de biomaterial. No grupo IV, na grande maioria dos espécimes, houve degradação do biomaterial. / This study objective was to histologically evaluate chitosan and bioactive glass effect on critical size bone defects created in dogþs mandibles, associated to osseointegrated implants. For this, it were utilized 8 young adult, without defined race dogs, that underwent third and fourth inferior premolars extractions, bilaterally. After 12 weeks, in extraction sites, it were installed two Ticp implants of 3.3 x 10.0 mm, followed by the creation of a 4mm diameter and 5mm depth cylindrical bone defects, buccally to each implant. The 8 animals were divided into 4 groups: Group I - Negative control (Blood clot), Group II - Defect filled with autogenous bone graft, Group III - Defect filled with Bioactive glass and Group IV - Defect filled with chitosan gel. It was realized bone biopsies at 15 and 90 days, in a total amount of 4 biopsies by biomaterial/period, that were processed and evaluated under histological descriptive analysis. As a result, it was observed, at 15 days, the formation of a fibrous tissue in the negative control group, and in the groups treated with autogenous bone graft, chitosan and Bioactive glass, it was observed dense pattern bone neoformation, with bone marrow spaces filled with fibrous tissue, of variable sizes and forms, with compact bone trabecules. At 90 days, it was observed the maturation of the new formed bone in these three groups. In group III (Bioactive glass), at 90 days, there is still the presence of the biomaterial. In group IV, in most specimens, the biomaterial was degenerated.
79

Índice de sucessos de implantes osseointegráveis que receberam carga imediata unitária: avaliação clínica de curto período em humanos

Ribeiro, Fernando Salimon [UNESP] 27 February 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-02-27Bitstream added on 2014-06-13T20:57:38Z : No. of bitstreams: 1 ribeiro_fs_me_arafo.pdf: 126598 bytes, checksum: 8ba8de70ef22ae37dbd2b5dbe93ca194 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi comparar, em curto período de tempo, o índice de sucesso de implantes osseointegráveis unitários submetidos à carga imediata, colocados imediatamente após a exodontia, com implantes colocados em rebordos cicatrizados. Foram examinados 71 pacientes consecutivos totalizando 91 implantes, sendo 48 realizados em clínica privada e 43 em cursos de especialização em implantodontia, entre dezembro de 2001 a dezembro de 2003. Sessenta e três implantes foram instalados em alvéolos e 28 em rebordos. Os critérios utilizados para avaliar o índice de sucesso foram os descritos por Albrektsson e Zarb (1993). Após o período de avaliação, 87 implantes examinados enquadravam-se dentro dos critérios de sucesso (95,6%). Dos quatro implantes perdidos, três haviam sido colocados em alvéolos (índice de sucesso de 95,2%) e um, em rebordo (96,4%). A diferença entre os índices de sucesso dos dois grupos não foi estatisticamente significante (p=0,76, teste Qui-quadrado). Podemos concluir, dentro das limitações deste estudo, que o carregamento imediato de implantes unitários, seja colocado em alvéolo ou rebordo, representa uma alternativa terapêutica com alta previsibilidade, comparado aos resultados encontrados na literatura para implantes seguindo o protocolo convencional de dois estágios cirúrgicos. / The aim of this study was to evaluate, in a short period of time, the success rate of immediate loading of single-tooth implants: immediate versus non-immediate implantation. Seventy-one patients were examined, totalizing 91 implants, which 48 implants were placed in private practice office and 43 were placed in dental school, between December 2001 and December 2003. Sixty-one implants were placed in fresh extraction sites, and 28 were placed in healed sites. Criteria to evaluate success rate were previously described by Albrektsson and Zarb (1993). After follow-up evaluation, 87 implants fulfilled the success rate criteria (95,6%). Four implants were lost, and among these, three were placed in fresh extraction sites (success rate 95,2%), and one placed in healed sites (success rate 96,4%). Rates of success between both groups was not statistically significant (p=0,76, Qui-square test). Within the limitation of the present study, it could be concluded that single-tooth osteointegrated implants submitted to immediate loading, in immediate and non-immediate implantation, represent a therapeutic alternative with high predictability, compared to the conventional protocol.
80

Análise da citocina IL-1ß e do polimorfismo do gene IL-1B + 3954 em pacientes com implantes osseointegrados

Melo, Rafaela Fernanda [UNESP] 27 March 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-03-27Bitstream added on 2014-06-13T19:36:30Z : No. of bitstreams: 1 melo_rf_me_arafo.pdf: 805451 bytes, checksum: 73a6301db4198e271a504deca1228bda (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Universidade Estadual Paulista (UNESP) / O objetivo deste estudo foi avaliar a concentração de interleucina-1 ß (IL-1ß) e o polimorfismo na posição +3954 do gene IL-1B em pacientes com a prótese sobre implante, em função, a pelo menos um ano. Vinte e cinco implantes, clinicamente satisfatórios, foram avaliados, em vinte pacientes saudáveis, sendo doze do gênero feminino e oito masculino. Exame clínico completo foi feito em todos os implantes e em um dente em condição de saúde de cada paciente. Amostra do sítio com maior profundidade de sondagem foi coletada para a quantificação da concentração de IL-1ß no fluido crevicular periimplantar/gengival. Células da mucosa bucal foram coletadas para extração do DNA genômico e análise do polimorfismo IL-1B +3954. Não foi detectada a presença da citocina IL-1ß nos sítios avaliados. Na população estudada houve uma predominância do genótipo homozigoto para o alelo C, o qual esteve presente em 75% dos pacientes avaliados. O genótipo homozigoto para o alelo T foi encontrado em apenas um (5%) paciente. Neste estudo não observamos uma relação entre a presença do alelo T e níveis aumentados de IL-1ß no fluido crevicular. / The aim of the present study was to determine interleukin-1ß (IL-1ß) levels and the polymorphism IL-1B +3954 in patients with implant loaded at least for one year. Twenty five healthy implans from twelve patients, twenty female and eight male, were examined. Clinical parameters were recorded from all implants and one teeth from each patient. Gingival crevicular fluid from the highest pocket depth was collected, with PerioPaper, to evaluate the level of the IL-1ß. Cells from buccal mucosa were collected for genomic DNA extraction and analyze the polymorphism IL-1B +3954. IL-1ß was not detected in any sites collected. At the studied population we observed prevalence from negative genotype, present in 75% of patients. The positive genotype was observed only in one (5%) patient from the population. Negative genotype is associated with health implants, and are nor related to elevated levels of IL-1ß on the crevicular fluid.

Page generated in 0.0644 seconds