• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 189
  • Tagged with
  • 191
  • 191
  • 165
  • 83
  • 56
  • 53
  • 51
  • 50
  • 34
  • 31
  • 27
  • 27
  • 26
  • 24
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Avaliação radiográfica e biomecânica da influência da osteoporose induzida em ratas, e seu tratamento com alendronato e estrógeno, sobre o tecido ósseo ao redor de implantes com osseointegração estabelecida

Giro, Gabriela [UNESP] 24 March 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-03-24Bitstream added on 2014-06-13T20:36:53Z : No. of bitstreams: 1 giro_g_me_arafo.pdf: 376478 bytes, checksum: 41b9f6bee6825f87f572627898751b2f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / O presente estudo teve como objetivo avaliar a influência da deficiência de estrógeno promovida pela ovariectomia (OVX) sobre o tecido ósseo ao redor de implantes com osseointegração estabelecida. Foram utilizadas ratas Wistar, com idade aproximada de 60 dias e peso variando entre 180g a 220g, submetidas à colocação de um implante na metáfise tibial. Os tratamentos utilizados foram eficientes na prevenção da perda óssea. Os animais que receberam a administração do alendronato apresentaram os melhores resultados para todas as análises realizadas. A deficiência de estrógeno decorrente da OVX acarretou prejuízos para a BMD, densidade radiográfica da região de osso medular e torque de remoção dos implantes. Esse quadro pôde ser revertido com a utilização dos tratamentos instituídos, com o alendronato apresentando os melhores resultados. / The aim of the present study was to evaluate the influence of estrogen deficiency due to ovariectomy (OVX) on the bone around osseointegrated titanium implants. Wistar female rats - approximately 60 days old, weighting from 180 to 220 g - were used. Digital radiographs were taken and the implants were submitted to the removal toque. The results showed a negative effect of the OVX on the BMD at the femur and lumbar regions, on the radiographic bone density at the cancellous bone and on the biomechanical characteristics of the bone tissue around the implants. The treatments were efficient preventing bone loss. The animals that received alendronate therapy showed the best results for all the analyzed variables. we can conclude that the estrogen deficiency due to OVX had a negative influence on the BMD, on the radiographic bone density at the cancellous bone and on the removal torque of the implants; however, such negative influence can be reversed with the adopted therapies, among which the alendronate seemed to be the best method for prevention and treatment of bone loss due to OVX.
82

Reação tecidual à superfície de titânio tratada pela irradiação laser e hidroxiapatita: análise histomorfométrica em ratos

Lacoski, Marcelo Kayatt [UNESP] 19 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-19Bitstream added on 2014-06-13T19:50:39Z : No. of bitstreams: 1 lacoski_mk_me_araca.pdf: 1635312 bytes, checksum: 4ce00b83ea1a8cdc3971e29bad471ebb (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O tratamento de superfície dos implantes está consolidado como um método capaz de acelerar e melhorar a qualidade da osseointegração, possibilitando técnicas de carregamento precoce dos implantes, diminuindo o tempo de tratamento e o número de insucessos. Desta forma, o objetivo deste estudo foi observar o comportamento celular do tecido subcutâneo de ratos submetidos a implantes de discos de titânio tratados com laser e laser e hidroxiapatita. Para isso, foram utilizados 32 discos de Ti cp implantados no tecido subcutâneo da região dorsal anterior e posterior de 16 animais (Rattus norvegicus albinus, Wistar), divididos em 2 grupos: LA - discos tratados com irradiação laser e LHA - discos tratados com irradiação laser e deposição de hidroxiapatita pelo método biomimético. Na análise histológica pôde-se observar que houve formação conjuntiva na periferia das amostras de titânio, com espessura e presença celular semelhantes, em ambos os grupos. Qualitativamente, o grupo LHA mostrou melhor organização tecidual nos tempos iniciais. Na análise morfométrica houve diferença estatisticamente significante entre os grupos, para a>0,01. / The treatment of surface of the dental implants is consolidated as a method capable to speed up and to improve the quality of the osseointegration, making possible precocious shipment techniques of the implantations, decreasing the time of treatment and the number of failures. Of this form, the aim of this study was to observe the cellular behavior of the subcutaneous tissue submitted to titanium implantations treated with laser and laser with hydroxyapatite. For this, 32 test implants of grade-I commercially pure titanium had been inserted in the connective tissue of the dorsal region of 16 male rats (Rattus norvegicus albinus, Wistar), divided in 2 groups: LA - test implants treated with laser irradiation and LHA - test implants treated with laser irradiation and deposition of hydroxyapatite by the biomimethic method. In the histological analysis it could be observed that it had conjunctive formation in the periphery of the titanium samples, with thickness and similar cellular presence, in both groups. Qualitatively, the group LHA better showed tissue organization in the initial times. There was statistic significant difference between the groups, of the measure of the thickness of the fibrous connective tissue formed in contact with tested implants, for a>0,01.
83

Análise qualitativa e quantitativa, pelo método dos elementos finitos, da distribuição de tensão em diferentes rebordos reabilitados com próteses metalocerâmicas sobre implantes do tipo cone Morse, de diferentes comprimentos / Qualitative and quantitative analysis by finite element method of the stress distribution at different bony edges rehabilitated with Morse taper implant- supported metalloceramic prostheses, of different lengths

Marcelo Bighetti Toniollo 16 December 2011 (has links)
O emprego dos implantes osseointegráveis na odontologia moderna tem sido crescente. Dentre os tipos de conexões existentes, o cone Morse tem se mostrado com vantagens e atrativos interessantes. Com relação ao comprimento, a aplicabilidade de implantes curtos para casos de perda óssea vertical intensa se faz muito presente, principalmente em áreas mandibulares posteriores, a fim de se evitar procedimentos cirúrgicos mais complexos que envolvam maior morbidade. Juntamente com a perda óssea, a necessidade da manutenção do plano oclusal nivelado é inquestionável, sendo necessário o uso de próteses sobre implantes curtos com dimensões maiores, podendo haver sobrecarga sobre tais implantes e estruturas de suporte. O método dos elementos finitos (MEF) possibilitou avaliar as tensões na superfície dos implantes e componentes, e na interface entre implantes e rebordo ósseo. Neste estudo foram usados modelos de implantes cone Morse e próteses sobre implantes do tipo metalocerâmicas, individualizadas, de diferentes dimensões, alojados em diferentes rebordos com reabsorção óssea vertical. Todas as estruturas foram desenhadas por meio do programa SolidWorks (SolidWorks Corporation, Massachusetts, USA), e análises qualitativas e quantitativas das tensões equivalentes de Von Mises foram realizadas nos rebordos ósseos e implantes por meio do programa AnsysWorkbench10.0 (Swanson, Analysis Systems, Inc., Houston, USA). Os grupos foram: grupo controle (3 implantes de 11mm comprimento), grupo 1 (implantes de 13mm, 11mm e 5mm comprimento), grupo 2 (1 implante de 11mm e 2 implantes de 5mm comprimento) e grupo 3 (3 implantes de 5mm comprimento). As alturas dos pilares usados foram 3.5mm para implantes de 13mm e 11mm (regulares) e 0.8mm para implantes de 5mm (curtos). Foram simuladas forças oblíquas de 365N em molares e 200N em pré-molares. Os resultados mostraram que, com relação aos implantes e componentes, os pilares com 0.8mm de altura geraram menores tensões equivalentes de Von Mises comparativamente aos de 3.5mm de altura. A associação de implantes curtos com coroas de maiores dimensões concentrou maiores valores e distribuição de tensões na superfície destes implantes, principalmente na face vestibular (direção das cargas oblíquas). O implante mais distal sempre concentrou maiores tensões. Já com relação ao osso, houve 50% mais tensão no osso cortical para os implantes de 5mm do que os de 13mm e 11mm de comprimento. Houve 80% mais tensão no osso esponjoso para os implantes de 5mm do que os de 13mm e 11mm de comprimento. Houve maior concentração de tensão na região óssea cervical aos implantes curtos. No entanto, tais implantes foram capazes de realizar boa dissipação das tensões aos ossos frente às cargas aplicadas, apesar de atingir seu limiar próximo entre deformação elástica e plástica para o osso trabecular. Implantes mais distais e/ou com maior mesa oclusal geraram regiões de maior tensão no osso circunjacente. Concluiu-se que pacientes que se faz necessária a instalação de implantes curtos associados a próteses sobre implantes de dimensões aumentadas necessitam de cuidadosa avaliação e ajuste oclusal, já que uma eventual sobrecarga nestes implantes curtos, e até mesmo nos de comprimento regular, podem gerar tensões que vão além do limiar fisiológico do osso circunjacente, podendo acarretar danos a todo o sistema. / The use of dental implants is increasing in dentistry. Among the different types of connections existent, the Morse taper has been highlighted on several positive features. Regarding to the length, the use of short implants in cases of severe vertical bone loss are becoming frequent, especially in mandibular posterior areas, avoiding more complex surgical procedures and greater morbidity. As a consequence of bone loss, the need for rehabilitation to maintain the occlusal plane level is unquestionable, leading to the use of implants prostheses with larger dimensions, which may cause overload on these short implants and the supporting structure. This finite element analysis (FEA) compared stress distribution on external surface of Morse taper implants, their abutments and at bone/implant interface of different bone ridges, varying implants length and dimensions of each metal-ceramic crowns. All structures were designed using the SolidWorks software (SolidWorks Corporation, Massachusetts, USA), and qualitative and quantitative analysis of the equivalent Von Mises stresses were ran on AnsysWorkbench10.0 (Swanson Analysis Systems, Inc., Houston, USA). Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11mm length; group 1, implants of 13mm, 11mm and 5mm length; group 2, 1 implant of 11mm and 2 implants of 5mm length; group 3, 3 implants of 5mm length. The abutments heights were 3.5mm for 13mm and 11mm implants (regular) and 0.8mm for 5mm implants (short). Evaluation was performed on Ansys software, with oblique loads of 365N for molars and 200N for premolars. The results, for implants and abutments, showed that abutments with 0.8mm height generated less von Mises stresses compared with 3.5mm height. The use of short implants associated with bigger crowns concentrated higher stress distribution and stress values on the surface implants, mainly on the vestibular side (oblique loads). The more distal implants had the higher stress mesures. The results for the bone showed that there was 50% higher stress on cortical bone on the 5mm implants length than 13mm and 11mm implants. There was 80% higher stress on trabecular bone for the 5mm implants length than 13mm and 11mm implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable to dissipate the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, which may compromise the whole system.
84

Análise da durabilidade, retenção e tensão em overdentures retidas por implantes associadas ou não a mini-implantes posteriores / Durability, retention and stress analysis of implants-retained overdentures associated or not to posterior mini-implants

Suleima do Vale Alves 02 June 2017 (has links)
O objetivo desse estudo in vitro foi analisar a durabilidade, retenção e tensão gerada nos implantes de overdenture retidas por sistema bola/O\'ring ou barra/clipe, associados ou não a mini-implantes na região posterior da mandíbula. Foram utilizados implantes anteriores cone-Morse (3,75 x 11 mm) e mini-implantes de corpo único (2 x 10 mm) e os grupos divididos em (n=12): G2O: overdenture sobre 2 implantes com bola/O´rings; G1B: overdenture sobre 2 implantes com barra/clipe; G4O: overdenture sobre 2 implantes com bola/O´rings e 2 mini-implantes na região posterior; G1B2O: overdenture sobre 2 implantes com barra/clipe e 2 mini-implantes na região posterior. Para avaliação qualitativa das áreas de compressão e/ou tração nos modelos em poliuretano, foi realizado o método de correlação de imagens digitais, com carregamento oclusal (300 N) e pontual (250 N) com captura em vista frontal e lateral dos modelos experimentais. Foi realizado ensaio de fadiga acelerada progressiva com cargas de 80 N, 140 N, 200 N, 260 N, 320 N e 380 N, frequência de 5Hz, totalizando 120.000 ciclos. Para avaliação da retenção os modelos foram submetidos a ensaio de tração previamente a termociclagem (Tempo 1), após 200 N (Tempo 2) e após 380 N (Tempo 3) e a força de retenção foi registradas em triplicata e a média obtida em cada tempo. A análise da durabilidade dos componentes retentivos foi realizada após os ensaios de tração nos tempos determinados por microscopia óptica. As imagens da aplicação de carga oclusal, mostraram que as tensões nos grupos 1B e 1B2O foram semelhantes, nos grupos 2O e 4O apresentaram tensões de tração na região anterior, porém no grupo 4O houve melhor distribuição por toda área analisada. Na aplicação de carga pontual, todos os modelos apresentaram tensões de compressão na região posterior e de tração na anterior, porém com maior intensidade nos modelos 2O e 4O, e menor intensidade nos modelos 1B e 1B2O. Nas análises sobre a retenção dos componentes, não houve diferença significativa (p < 0,05) entre os grupos 1B-1B2O, porém houve diferença significativa entre os grupos 2O-4O, notando maior força retentiva no grupo 4O. As comparações entre os grupos, 1B-2O e 1B2O-4O houve diferença significativa, sendo que os grupos com sistema barra/clipe obtiveram maior retenção que os grupos com O´rings. Nas imagens microscópicas não houve diferença significativa na estrutura interna dos O´rings, porém houve diferença significativa nos clipes. Conclui-se que a durabilidade, retenção e distribuição de tensão não se altera com a colocação de mini-implantes posteriores em overdentures com sistema retentivo barra/clipe. Com sistema retentivo bola/O\'ring a instalação de mini-implantes aumentou a força de retenção e favoreceu a distribuição das tensões, reduzindo a alavanca para posterior. / The purpose of this in vitro study was to analyze the durability, retention and strength caused for implants-retained overdentures by ball/O-ring system or bar/clip, associated or not mini-implants in the posterior region of the mandible. Anterior Morse taper connection implants (3.75 x 11 mm) and single-body mini-implants (2 x 10 mm) were used and the groups divided to (n=12): G2O: implants-retained overdentures 2 implants with ball/O-rings ; G1B: implants-retained overdentures 2 bar/clip implants; G4O: implants-retained overdentures 2 implants with ball/O-rings and 2 mini-implants in the posterior region ; G1B2O: implants-retained overdentures 2 implants with bar/clip and 2 mini-implants in the posterior region. For the qualitative evaluation of compression and/or traction areas in polyurethane models, a digital image correlation method (DIC) with occlusal (300 N) and punctual (250 N) loading was applied with frontal and lateral views of the experimental models. An accelerated progressive fatigue test with loads of 80 N, 140 N, 200 N, 260 N, 320 N and 380 N, frequency of 5 Hz, completing120,000 cycles. In order to evaluate the retention force, the models were submitted to traction force, previously to thermocycling (Time 1) after 200 N (Time 2) and posteriorly 380 N (Time 3), being the retention force recorded in triplicate. The durability analysis, by optic microscopy, of the retentive components was performed after the traction tests at the determined times. The application images of the occlusal load, showed that the stress in groups 1B and 1B2O were similar, in groups 2O and 4O presented stress in the anterior region, but in the 4O group, there was better distribution throughout the analyzed area. In the application of punctual loading, all the models presented compression tensions in the posterior region and traction in the anterior one, but with greater intensity in the 2O and 4O models, and lower intensity in the 1B and 1B2O models. In the retention analyzes of the components, there was no significant difference (p <0.05) between groups 1B-1B2O, but there was a significant difference between groups 2O-4O, noting a higher retentive force in the 4O group. The comparisons between the groups, 1B-2O and 1B2O-4O showed a significant difference, and the groups with bar/clip systems obtained higher retention than the groups with O-rings. In the microscopic images, there was no significant difference in the O-rings internal structure, but there was a significant difference in the clips images. It was concluded that the durability, retention and stress distribution do not change with the placement of posterior mini-implants in overdentures with retentive bar/clip system. With retentive system ball/O-ring the installation of mini-implants increased the retention force and favored much the distribution of the stress, thus reducing the forefoot leverage to the posterior part of the prosthesis.
85

Efeito do material de recobrimento na deformação sofrida por infra-estruturas de próteses fixas implanto-suportadas, utilizando extensômetros lineares elétricos

Antônio Francisco Grando 31 March 2003 (has links)
O sucesso dos implantes osseointegrados tem a influência decisiva dos aspectos biomecânicos, os quais interagem implantes, tecido ósseo e as próteses. O equilíbrio das forças que atuam sobre este complexo, remete-nos às diversas técnicas e materiais utilizados para a confecção das próteses fixas implanto-suportadas. O desenvolvimento de técnicas e materiais, bem como os desenhos das próteses vem trazendo um novo alento nas pesquisas. Este trabalho teve como objetivo averiguar a influência dos materiais de recobrimento estético, utilizados na confecção de próteses fixas implanto-suportadas, com relação à deformação destas próteses. Esta análise foi feita utilizando-se extensômetros lineares elétricos, analisando dois materiais de recobrimento. Um corpo de prova simulando uma prótese fixa de arco total, fundida em liga de paládioprata e recoberta em uma de suas metades por porcelana e na outra, por resina acrílica termopolimerizável. O corpo de prova foi fixado a um modelo-mestre e, após, aplicada uma carga estática vertical de 35,2 N, na extremidade livre, a uma distância de 10, 15 e 20 mm para distal do centro do implante terminal. Os resultados demonstraram que a aplicação de materiais de recobrimento estético, sobre uma infraestrutura metálica, tornam a mesma mais rígida e conseqüentemente com menor deformação. Outro fator confirmado nesta pesquisa foi a influência direta da extensão da extremidade livre que, nos pontos mais distantes de aplicação da carga, proporcionou maiores deformações. A pesquisa demonstrou que a porcelana proporciona menores índices de deformação da infra-estrutura metálica a ela associada, porém, fatores clínicos como qualidade e quantidade óssea, número e disposição dos implantes é que definem a escolha do material de recobrimento mais apropriado para cada situação. / The success of osseointegrated implants has a decisive influence of biomechanical aspects in wich implants, bone tissue and prosthesis are involved. The balance between the forces acting on this complex refer us to the diversity of methods and materials used to fabricate implant supported prosthesis. The aim of this study was to verify the influence of aesthetic covering materials on the deformation of cantilevered frameworks. Strain gauges were bonded to the inferior surface of a silver-palladium framework covered with ceramic and thermoacrylic resin on each of its two halves. The framework was fixed to a metallic master model and a 35.2N vertical static load was apllied to the free end at the distances of 10, 15 and 20mm distal to the terminal abutment. The results showed that the use of a rigid material such as ceramic stiffen even more the framework, with consequently less deformation. Another finding that was confirmed in this study was the direct influence of cantilever length on deformation of implant supported frameworks.
86

Avaliação da deformação gerada nos componentes intermediários de prótese fixa implanto-suportada com diferentes alturas, com a utilização de extensômetros lineares elétricos / Assessment of the deformation of the generated in different heights of abutments of mandibular implant-supported prosthesis, with the use of strain Gauges

Valdey Suedam 10 June 2005 (has links)
Em prótese total fixa implanto-suportada as diferentes alturas dos intermediários traduzem-se em diferentes braços de alavanca aos quais os implantes são submetidos levando a um efeito de deformação dos componentes que até o momento é desconhecido. O objetivo deste trabalho foi verificar a deformação gerada em diferentes alturas de componentes intermediários de prótese total fixa mandibular implanto-suportada. Para isto foi utilizado um modelo mestre de forma circular confeccionado em aço comum (Aço 1010/20) com cinco perfurações onde foram adaptadas as réplicas de fixação de 3,75mm de diâmetro, nas quais foram fixados os intermediários. O trabalho apresentou dois grupos de três corpos de prova cada, divididos de acordo com o tipo de liga das infra-estruturas(CoCr ou PdAg) e altura dos intermediários (4,0 mm, 5,5 mm e 7,0 mm), respectivamente. Foi aplicada uma força de 100N, em um ponto de referência pré-determinado na extremidade livre, a uma distância de 15mm do centro da réplica de fixação terminal e realizadas leituras das deformações geradas na mesial e na distal de cada intermediário, com o uso de extensômetros lineares elétricos. Os resultados do estudo demonstraram que o aumento da deformação captada no intermediário adjacente ao cantilever é promovido pelo aumento da altura dos intermediários e também pela utilização de uma liga de alto módulo de elasticidade. / In implant-supported prosthesis the different heights of abutments represent different lever arms to which the implants are submitted, leading to a deformation of the components that is not completely understood. The objective of this study was to assess the deformation ocurring in different heights of abutments of mandibular implant-supported fixed prosthesis. A circular master cast made of steel (Steel 1010/20) was used with five perforations containing implant replicas of 3,75mm of diameter in which the abutments were seated. The specimens were divided in two groups of three specimens each, according to the type of alloy of the framework (CoCr or PdAg) and the abutment's height (4,0 mm, 5,5 mm and 7,0 mm), respectively. A force of 100N was applied at a point 15mm distal to the center of the terminal abutment. Readings of the deformations generated on the mesial and distal aspects of the abutment were obtained with the use of strain gauges. The results of this study demonstrated that the deformation observed in the abutments adjacent to the cantilever arm is proportional to the increase of the abutment's height and elastic modulous of the alloy.
87

Análise microbiológica da vedação com selante industrial de microgaps nas diferentes conexões implantares: estudo in vitro / Microbiological analysis of the seal with industrial sealant on the microgaps in the different implant connections: in vitro study

Fábio Sanches Magalhães Tunes 29 June 2018 (has links)
A utilização de implantes osseointegráveis e componentes protéticos tornaram-se recursos muito viáveis à resolução de casos simples e complexos na odontologia reabilitadora. No entanto, a junção implante componente pode apresentar problemas, tais como a presença de um microgap entre essas partes constituintes. Assim, vários materiais tem sido testados na tentativa de obstruir esse espaço, com resultados controversos. O objetivo deste estudo foi avaliar in vitro o comportamento de um adesivo anaeróbico (Loctite® 510, Henkel Ltda) monocomponente, de alta resistência e inerte, na vedação do microgap impedindo a passagem bacteriana do meio externo para o interno do conjunto. Foram utilizados 90 implantes de conexão externa hexagonal (n = 30), conexão interna hexagonal (n = 30) e conexão interna cônica (n = 30), divididos em Grupo Controle (n = 45) e Grupo Teste (n = 45). Os implantes foram abertos em fluxo laminar e cada unidade recebeu 3l de BHI estéril internamente. Sobre cada unidade era parafusado um componente protético especifico para cada marca e com torques recomendados pelos fabricantes com torquímetro digital. Os conjuntos Teste receberam ainda uma fina camada de adesivo que era aplicada com microbrush entre as partes; e todas as unidades dos grupos Controle e Teste foram vedados com material obturador provisório na sua porção mais coronal. Cada conjunto foi então imerso em 75 l de Enterococcus faecalis (ATCC 29212) em minitubos até o limite entre a junção implante/componente protético. Todas as amostras foram incubadas em estufa bacteriológica por 7, 14 e 28 dias a 37oC antes de serem reabertas. Após o período proposto, o conteúdo interno dos implantes foi coletado com cones de papel estéreis, diluído e semeado em placas de Petri, incubadas por 48 horas. Houve diferença significante entre o grupo teste e controle no grupo de conexão externa hexagonal, em todos os tempos (Teste de Fischer e Qui-quadrado, p 0.05). O adesivo anaeróbico testado funciona como barreira, não permitindo a migração de bactérias para o meio interno do conjunto implante/componente protético. / The use of dental implants and prosthetic components have become very feasible resources to solve simple and complex cases in rehabilitation dentistry. However, the implant component junction may present problems, such as the presence of a microgap between these components parts.Therefore, several materials have been tested in an attempt to obstruct this space, with controversial results. The objective of this study was to evaluate in vitro the behavior of an anaerobic monocomponent adhesive (Loctite® 510, Henkel Ltda), high resistance and inert characteristics, in the microgap seal preventing bacterial passage from the external side to the inner side of the assembly. A total of 90 implants were used, with hexagonal external connection (n = 30), internal hexagonal connection (n = 30) and internal conical connection (n = 30) divided into Control Group (n = 45). Implants were opened in laminar flow cabinet and each unit received 3l of sterile BHI internally. On each unit a specific prosthetic component was screwed in for each brand and with torques recommended by the manufacturers with digital torque wrench. The sets of Test also received a thin layer of adhesive that was applied with microbrush between the parts; and all units of the Control and Test groups were sealed with provisional obturator material in their most coronal portion. Each set was immersed in 75 l of Enterococcus faecalis (ATCC - 29212) in mini-tubes to the limit between the implant / prosthetic component junction. All samples were incubated in a bacteriological incubator for 7, 14 and 28 days at 37oC before being reopened. After the proposed period, the internal contents of the implants were collected with sterile paper cones, diluted and seeded in Petri dishes, incubated for 48 hours. There was a significant difference between the test and control groups in the hexagonal external connection group at all times (Fischer and Chi-square test, p 0.05). The anaerobic adhesive tested works as a barrier, not allowing the migration of bacteria into the internal environment of the implant / prosthetic component assembly.
88

Efeitos do tratamento químico na descontaminação de superfícies de implantes metálicos: estudo microscópico em subcutâneos de ratos / Effects of chemical treatment of surfaces in decontamination of metallic implants: microscopic study in subcutaneous rats

Rafael Mansano de Castro Lara 09 March 2012 (has links)
O objetivo deste trabalho foi avaliar o efeito do tratamento químico com ácido cítrico, tetraciclina, EDTA e ácido fosfórico em discos de titânio de superfícies lisas e rugosas, após serem contaminados por biofilme bacteriano humano, e inseridos no tecido conjuntivo subcutâneo de ratos. Utilizou-se 180 discos de titânio, sendo 90 lisos e 90 rugosos, que foram colocados em 19 placas de acrílico utilizadas por voluntários durante 7 dias. Estes discos foram divididos em 12 grupos contendo 15 discos cada um: Grupo 1L: 15 discos lisos tratados com ácido cítrico; Grupo 1R: 15 discos rugosos tratados com ácido cítrico; Grupo 2L: 15 discos lisos tratados com tetraciclina ácida; Grupo 2R: 15 discos rugosos tratados com tetraciclina ácida; Grupo 3L: 15 discos lisos tratados com EDTA; Grupo 3R: 15 discos rugosos tratados com EDTA; Grupo 4L: 15 discos lisos tratados com ácido fosfórico; Grupo 4R: 15 discos rugosos tratados com ácido fosfórico; Grupo CL: 15 discos lisos que não receberam descontaminação (controle positivo liso); Grupo CR: 15 discos rugosos que não receberam descontaminação (controle positivo rugoso); Grupo EL: 15 discos lisos que não foram contaminados (controle negativo liso) e Grupo ER: 15 discos rugosos que não foram contaminados (controle negativo rugoso). Estes discos foram implantados no subcutâneo de ratos, os quais foram sacrificados após 7, 28 ou 84 dias. Foi realizada a avaliação microscópica descritiva e quantitativa do tecido conjuntivo formado nestes ratos. Foram avaliadas as médias das espessuras das cápsulas, a densidade de fibroblastos e de neutrófilos nos 3 períodos de tempo. Os resultados mostraram diferença na densidade de neutrófilos principalmente aos 7 dias e o ácido fosfórico mostrou os melhores resultados neste período, e ao final de 84 dias todos os tratamentos apresentaram resultados similares inclusive com relação ao grupo controle contaminado. Com relação à rugosidade os discos de superfícies lisas, apresentaram menor média na espessura da cápsula comparandose com os discos de superfícies rugosas, talvez demonstrando um aspecto de maior biocompatibilidade da superfície lisa após receber o tratamento de descontaminação, o que sugeriria maior efetividade na descontaminação dos protótipos lisos. / The purpose of this investigation was to evaluate the effects of treatment with citric acid, tetracycline, EDTA and phosphoric acid in titanium disks in smooth and roughened surfaces contaminated by bacterial biofilms in the connective tissue of rats. One hundred eighty titanium disks were used; 90 smooth surfaces and 90 roughened titanium surfaces, which were placed in 19 acrylic plates that were used by volunteers for 7 days. These disks were divided into 12 groups containing 15 disks each; Group 1L: 15 smooth disks were treated with citric acid; Group 1R: 15 roughened disks were treated with citric acid; Group 2L: 15 smooth disks were treated with tetracycline acid; Group 2R: 15 roughened disks were treated with tetracycline rough acid; Group 3L: 15 smooth disks were treated with EDTA; Group 3R: 15 roughened disks were treated with EDTA; Group 4L: 15 smooth disks were treated with phosphoric acid; Group 4R: 15 roughened disks were treated with phosphoric acid; Group CL: 15 smooth disks received no econtamination (smooth positive control); CR: 15 roughened disks did not receive decontamination (roughened positive control); EL: 15 smooth disks were not infected (smooth negative control) and ER: 15 roughened disks were not infected (roughened negative control). These disks were implanted subcutaneously in rats that were sacrificed after 7, 28 or 84 days. A descriptive and quantitative microscopic evaluation was performed. The average thickness of the capsules and the density of fibroblasts and neutrophils in three time periods were evaluated. The results showed differences in the density of neutrophilis mainly at 7 days and phosphoric acid showed the best results in this period, and at the end of 84 days, all treatments showed similar results even with the control group infected. In relation to the roughness, the smooth disks had a lower average capsule thickness compared with roughened disks, perhaps demonstrating an aspect of greater biocompatibility smooth surface, which would suggest greater effectiveness in decontamination of smooth disks.
89

Avaliação da deformação gerada na região peri-implantar de prótese fixa implantossuportada, com a utilização de extensômetros lineares elétricos / Evaluation of peri-implant bone deformation of a mandibular cantilevered implant-supported prosthesis, with the use of strain gages

Valdey Suedam 07 August 2009 (has links)
O comportamento mecânico das próteses parciais fixas implanto-suportadas são foco de vários estudos, onde o entendimento do processo de transmissão de forças mastigatórias e suas reações na estrutura óssea peri-implantar ainda não são totalmente compreendidos. Por isso, o objetivo deste trabalho foi verificar a deformação gerada na região peri-implantar de prótese parcial fixa mandibular. Para isto foi utilizado um modelo de poliuretano em forma de U simulando o osso mandibular com dois implantes hexágono externo de 3,75mm de diâmetro por 13mm de comprimento, nos quais foram fixados intermediários multi-unit. O trabalho apresentou dois grupos divididos de acordo com o tipo de liga das infraestruturas (CoCr ou PdAg) os quais foram submetidos a quatro situações de aplicação de carga. Foram aplicadas forças de 300N, nos pontos de referência pré-determinados na barra entre os implantes e na extremidade livre (5mm, 10mm e 15mm de cantilever). Foram realizadas leituras das deformações geradas na distal, lingual, mesial e vestibular de cada implante, com o uso de extensômetros lineares elétricos, as quais foram correlacionadas com a teoria de remodelação óssea proposta por Frost. Os resultados do estudo demonstraram que a deformação é influenciada pelo ponto de aplicação de carga e pelo módulo de elasticidade da liga da barra. A deformação é diretamente proporcional ao comprimento do cantilever, onde comprimentos maiores do que 10mm provocam tensões que superam a tensão máxima fisiológica proposta pela teoria de Frost. / The mechanical behavior of implant-supported prosthesis is focus of some studies, with the process of bite forces transmissions and its peri-implant bone reactions is not completely understood yet. Therefore, the aim of this study was to verify the deformation in peri-implant region of mandibular fixed partial prosthesis. A U shaped polyurethane model was used to simulated the mandibular bone with two external hexagon implants with 3.75mm of diameter an 13mm of length, provided with multi-unit abutments. Two groups were formed according to the type of alloy of the framework (CoCr or PdAg), which were submitted to four load conditions. Loads of 300N were applied, in the predetermined points on the framework between the implants and the cantilever (5mm, 10mm and 15mm distal to the terminal implant). Readings of the deformations generated on the distal, lingual, mesial and bucal aspects of each implant were obtained with the use of strain gages, which were correlated to the theory proposed by Frost on bone remodeling. The results of the study demonstrated that deformation is influenced by the point of load application and by the elastic modulus of the alloy of the framework. The deformation is directly proportional to the cantilever length. Lengths bigger than 10mm generate tensions that exceed the maximum effective strain proposed by Frost.
90

Qualidade de vida, condições clínicas e radiográficas de dois implantes não unidos submetidos à carga imediata de overdenture mandibular: estudo piloto / Quality of life, clinical and radiographic parameters of two immediate loaded unsplinted implants supporting mandibular overdenture: pilot study

Cavalheiro, Suellen Cristina 12 March 2018 (has links)
Submitted by Rosangela Silva (rosangela.silva3@unioeste.br) on 2018-06-25T20:01:46Z No. of bitstreams: 2 Suellen Cristina Cavalheiro.pdf: 1389300 bytes, checksum: d73926186003baf2e89cc2421c60b2a4 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-06-25T20:01:46Z (GMT). No. of bitstreams: 2 Suellen Cristina Cavalheiro.pdf: 1389300 bytes, checksum: d73926186003baf2e89cc2421c60b2a4 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-12 / This pilot study evaluated the clinical and radiographic peri-implant conditions of two unsplinted implants immediate loaded with mandibular overdentures, as well, evaluated the oral health related quality of life (OHRQoL) in these patients. Materials and Methods: ten totally edentulous patients received 20 implants with ball attachment, being 6 immediate loaded (test group) and 4 conventional loaded (control group). For OHRQoL assessment, the OHIP-EDENT questionnaire was applied before the implants insertion, 3 and 6 months after. After 6 months of implant insertion, the following clinical parameters were evaluated: probing depth, width of the keratinized mucosa, modified bleeding index, modified plaque index. The marginal bone loss was obtained by analyses of periapical radiographs at the day of implant insertion, 3 and 6 months after. Results:There was a significant improvement of quality of life at 3 months in immediate loaded group and at 6 months at the conventional loaded group comparing to initial time (p<0,05) with no significant difference between groups (p>0,05). There was no significant difference between groups for the clinical and radiographic parameters at 6 months.Conclusion: There was no significant difference between groups in all quality of life, clinical and radiographic parameters, however the immediate load provided a better quality of life before the conventional load. Long term studies may be conducted due to follow peri-implant indices and to obtain success index of theimplants. / Esse estudo piloto avaliou as condições peri-implantares clínicas e radiográficas de dois implantes não unidos submetidos a carga imediata reabilitados com overdenture mandibular, bem como avaliou a qualidade de vida relacionada à saúde oral nesses pacientes. Materiais e Métodos: Dez pacientes desdentados totais receberam 20 implantes com conexão bola, sendo 6 pacientes submetidos a carga imediata (grupo teste) e 4 a carga convencional (grupo controle). Para avaliação da qualidade de vida foi aplicado o questionário OHIP-EDENT antes da instalação dos implantes, 3 e 6 meses após. Para verificação das condições clínicas, foram analisados: profundidade de sondagem, largura da mucosa queratinizada, índice de sangramento do sulco modificado e índice de placa modificado 6 meses após a instalação dos implantes. A perda óssea marginal foi obtida através da análise de radiografias periapicais no ato da instalação dos implantes, 3 e 6 meses após. Resultados: Houve uma melhora estatisticamente significativa da qualidade de vida em 3 meses para o grupo carga imediata e em 6 meses para o grupo carga convencional em relação ao tempo inicial (p<0,05), sem diferença estatística entre os grupos (p>0,05). Não houve diferença estatística entre os grupos para os índices clínicos e radiográficos em 6 meses. Conclusão: Não houve diferença entre os grupos nos parâmetros clínicos, radiográficos e qualidade de vida, porém a carga imediata proporcionou uma melhor qualidade de vida antes da carga convencional. Estudos em longo prazo devem ser feitos para acompanhar os índices peri-implantares e obter a taxa de sucesso dos implantes.

Page generated in 0.0785 seconds