• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 91
  • 6
  • 5
  • 2
  • 1
  • Tagged with
  • 105
  • 71
  • 20
  • 19
  • 13
  • 13
  • 11
  • 10
  • 10
  • 10
  • 9
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Beneficios estipulados en la Ley 30056 “Ley de Impulso al Desarrollo Productivo y al Crecimiento Empresarial” y su influencia en la voluntad de formalización en los comerciantes del mercado, La Victoria-2018

Siban Espinoza, Geraldine Estefania, Siban Espinoza, Cris Estefania January 2018 (has links)
Esta investigación se desarrolló en el mercado El Inca, que se encuentra localizado en el distrito La Victoria, lugar que evidencia una amplia actividad comercial de las Mypes que se caracterizan por ser informales, debido a su falta de interés por los beneficios que proporciona la ley 30056. La investigación tiene como objetivo principal determinar la influencia de los beneficios de la Ley 30056 “ley de impulso al desarrollo productivo y al crecimiento empresarial” en la voluntad de formalización en los comerciantes del mercado El Inca. Asimismo, el tipo corresponde a descriptivo correlacional con diseño no experimental descriptivo transversal, dado que, se analizará el conocimiento de los beneficios que concede la normativa a las Mypes formalizadas, además de la predisposición de los comerciantes a formalizarse, mediante la respectiva aplicación de cuestionarios a una muestra de 55 comerciantes cuyos negocios presentan informalidad. Referente a la información recopilada se realizará mediante el programa Excel, el cual, proporcionará cuadros estadísticos, mostrando las frecuencias absolutas como porcentuales, además, se utilizará para realizar la prueba de fiabilidad de los instrumentos el paquete estadístico SPSS, para interpretar y analizar adecuadamente los resultados.
82

[en] THE USE OF T-VAR MODELS ON THE EVALUATION OF THE CREDIBILITY IMPACT ON MONETARY POLICY / [pt] UTILIZAÇÃO DE MODELOS T-VAR NA AVALIAÇÃO DO IMPACTO DA CREDIBILIDADE NA POLÍTICA MONETÁRIA

BERNARDO ARAUJO DE LUCENA 17 April 2019 (has links)
[pt] O trabalho conduz uma análise empírica sobre como a credibilidade da política monetária influencia as reações da atividade econômica e da inflação a um aumento da taxa de juros. Como parte da metodologia, um índice de credibilidade foi construído a partir do desvio da expectativa de inflação com relação à meta para o período. Esse índice foi empregado em um modelo T-VAR junto a séries de hiato do produto, núcleo da inflação, taxa de câmbio e taxa de juros para gerar funções resposta ao impulso generalizadas através das quais foi possível comparar a dinâmica entre os regimes com credibilidade e sem credibilidade. As principais conclusões foram que a presença de credibilidade reduz o custo do aumento aos juros e intensifica a redução da inflação a um aumento da taxa de juros. / [en] The work conducts an empirical assessment on how monetary policy credibility influences the reaction of output and inflation to an increase in interest rate. As part of the methodology, a credibility index was built based on the deviation of the expected inflation from its target for a given period. This index was employed in a T-VAR model – also containing series of output gap, inflation core, exchange rate and interest rate – in order to generate generalized impulse response functions through which the dynamics of the with- and without- credibility regimes could be compared. The main conclusions were that the presence of credibility lowers the cost of raising interest rates and strengthens the inflation reduction in response to an interest rate increase.
83

Evaluación de infraestructuras para el impulso sostenible de la comarca de la costera

Juan García, Francisco 08 January 2016 (has links)
[EN] The role of infrastructures in boosting the economic growth of the regions is widely recognized. In many cases, an infrastructure is selected by subjective reasons. Selection of the optimal infrastructure for sustainable economic development of a region should be based on objective and founded reasons, not only economical, but also environmental and social. In this paper is developed such selection through a hybrid method based on Delphi, analytical hierarchy process (AHP), and VIKOR (from Serbian, VIseKriterijumska Optimizacija I Kompromisno Resenje). To do this, a panel of experts assesses both the infrastructures and the drivers for their selection. The method lets us to verify the consistency of answers from experts. In our case, AHP obtains preference values for each infrastructure using the eigenvector method. Meanwhile, the VIKOR method evaluates whether the proposed is the one that best fits the prevailing view, minimizing the regret to the most separate opinions. Thus, for La Costera (Spain), the region under study, this research work concludes that the thematic route is the optimal infrastructure. / [ES] El papel de las infraestructuras en el impulso del crecimiento económico de las regiones es ampliamente reconocido. En muchos casos, una infraestructura es seleccionada por razones subjetivas. La selección de la infraestructura óptima para el desarrollo sostenible de una región debería basarse en razones objetivas y justificadas, y no sólo económicas, sino también ambientales y sociales. En esta tesis doctoral se desarrolla tal selección a través de un método híbrido basado en Delphi, el Proceso Analítico Jerárquico (AHP) y VIKOR (del serbio, VIseKriterijumska Optimizacija I Kompromisno Resenje). Para ello, un panel de expertos evalúa tanto las infraestructuras como los criterios para su selección. El método permite verificar la consistencia de las respuestas de los expertos. En nuestro caso, AHP proporciona valores de preferencia para cada infraestructura usando el método del autovector. Por su parte, el método VIKOR evalúa si la infraestructura propuesta es la que mejor se ajusta a la opinión predominante, minimizando la pena de las opiniones más divergentes. Así, para la comarca de La Costera, la región en estudio, esta tesis concluye que la ruta temática es la infraestructura óptima. / [CA] El paper de les infraestructures en l'impuls del creixement econòmic de les regions és àmpliament reconegut. En molts casos, una infraestructura és seleccionada per raons subjectives. La selecció de la infraestructura òptima per al desenrotllament sostenible d'una regió hauria de basar-se en raons objectives i justificades, i no sols econòmiques, sinó també ambientals i socials. En esta tesi doctoral es desenrotlla tal selecció a través d'un mètode híbrid basat en Delphi, el Procés Analític Jeràrquic (AHP) i VIKOR (del serbi, VIseKriterijumska Optimizacija I Kompromisno Resenje). Per a això, un panell d'experts avalua tant les infraestructures com els criteris per a la seua selecció. El mètode permet verificar la consistència de les respostes dels experts. En el nostre cas, AHP proporciona valors de preferència per a cada infraestructura usant el mètode de l'autovector. Per la seua banda, el mètode VIKOR avalua si la infraestructura proposada és la que millor s'ajusta a l'opinió predominant, minimitzant la pena de les opinions més divergents. Així, per a la comarca de la Costera, la regió en estudi, esta tesi conclou que la ruta temàtica és la infraestructura òptima. / Juan García, F. (2015). Evaluación de infraestructuras para el impulso sostenible de la comarca de la costera [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/59522
84

Modeling of the behavior of medium voltage insulators against lightning overvoltages / Modelagem do comportamento de isoladores de média tensão contra sobretensões de impulsos atmosféricos

Shigihara, Miltom 05 October 2015 (has links)
Lightning causes important transient disturbances on transmission and distribution systems, with consequent damages to equipment, outages, and general decrease of the power quality. The assessment of the lightning dielectric strength of power equipment is generally based on tests performed using the standard lightning impulse voltage (1.2 / 50 µs waveshape), although the characteristics of the lightning overvoltages depend on many parameters and may vary widely. The behavior of insulators when subject to non-standard impulses depends both on the voltage amplitude and waveshape, and therefore a reliable model is required to produce the corresponding volt-time curves. Although there is no method universally accepted for this purpose, one of the most used is the Disruptive Effect (DE) model, which is based on the integration method concept. The application of this model involves the estimation of some parameters for which different procedures have been proposed in the literature, as for instance the procedures by Darveniza and Vlastos, by Hileman, by Chowdhuri et al., and by Ancajima et al. Tests of representative lightning overvoltages were performed to obtain the critical flashover overvoltages (CFO) and the volt-time curves of typical porcelain pin-type insulators considering three standard medium-voltage distribution classes (15 kV, 24 kV, and 36 kV) and five impulse voltage waveshapes, of both polarities. These tests provided data for the analyses of the insulators\' behavior and the results obtained using the different procedures for estimating the DE parameters. It is shown that in some cases insulator flashover is not predicted. A new method is then developed and proposed for evaluating the dielectric behavior of MV insulators. The method is validated using the typical insulators of the three voltage classes and the five lightning impulse voltages considered, of positive and negative polarities. The calculated volt-time curves showed in general a good agreement with the measured results for all the cases studied. The mean difference between the measured and calculated times to breakdown, for all the cases considered, was about 1.3 s; while the maximum difference was 4.0 s. The application of the proposed method to evaluate the occurrence of insulator flashovers in the shield wire line (SWL) system implemented in the State of Rondônia due to nearby lightning strikes supports previous conclusions that indicate that lightning has a significant impact on the SWL system performance in regions with high ground flash density. / Descargas atmosféricas produzem distúrbios transitórios significativos em sistemas de transmissão e distribuição, com consequentes danos em equipamentos, interrupções e redução geral na qualidade de energia elétrica. A avaliação da suportabilidade dielétrica frente às descargas atmosféricas do equipamento de potência é geralmente baseada em ensaios realizados usando o impulso atmosférico de tensão normalizada (forma de onda 1.2 / 50 µs), contudo as características das sobretensões atmosféricas dependem de muitos parâmetros e podem variar amplamente. O comportamento dos isoladores quando sujeitos a impulsos não normalizados depende tanto da magnitude como da forma de onda da tensão, e então um modelo confiável é necessário para se obter as curvas tensão-tempo correspondentes. Embora não haja um método universalmente aceito para essa finalidade, um dos mais utilizados é o modelo de Efeito Disruptivo (DE), que é baseado no conceito do método de integração. A aplicação desse modelo envolve a estimativa de alguns parâmetros para os quais diferentes procedimentos têm sido propostos na literatura, como por exemplo, os procedimentos de Darveniza e Vlastos, de Hileman, de Chowdhuri et al. e de Ancajima et al. Ensaios de sobretensões atmosféricas representativas foram feitos para obter as tensões de descarga disruptiva (CFO) e as curvas de tensão-tempo de isoladores de porcelana típicos, tipo pino, considerando três classes de tensão de distribuição de média tensão (15 kV, 24 kV e 36 kV) e cinco formas de onda de impulso de tensão, de ambas as polaridades. Estes ensaios proporcionaram dados para as análises do comportamento dos isoladores e os resultados obtidos usando os diferentes procedimentos para estimar os parâmetros necessários para a aplicação do modelo do Efeito Disruptivo. É mostrado que em alguns casos a disrupção no isolador não é prevista por tais procedimentos. Um novo método é, então, desenvolvido e proposto para avaliar o comportamento dielétrico dos isoladores de média tensão. O método é validado usando os isoladores típicos das três classes de tensão e as cinco formas de tensões de impulso atmosféricos consideradas, de polaridades positiva e negativa. As curvas tensão-tempo calculadas mostraram, em geral, boa concordância com os resultados medidos para todos os casos estudados. A diferença média entre os tempos de disrupção medidos e calculados, para todos os casos considerados, foi da ordem de 1,3 s; enquanto a máxima diferença foi de 4,0 s. A aplicação do método proposto para avaliar a ocorrência de disrupções em isoladores do Sistema de Cabo Para-raios Energizados (PRE), implementado no estado de Rondônia, devido a descargas atmosféricas indiretas, apoia as conclusões previamente obtidas que indicam que as descargas atmosféricas têm impacto significativo sobre o desempenho do sistema PRE em regiões com alta densidade de descargas para solo.
85

Avaliação do comportamento dielétrico de isoladores de distribuição de média tensão frente a impulsos atmosféricos com formas de onda não normalizadas / Analysis of the dielectric behavior of medium voltage insulators under non-standard lightning impulse voltages

Braz, Celso Pereira 18 April 2011 (has links)
As linhas de distribuição de energia estão freqüentemente expostas a sobretensões causadas por descargas atmosféricas diretas e indiretas. As formas de onda dessas sobretensões têm uma faixa de variação muito ampla e podem diferir bastante do impulso atmosférico normalizado utilizado em ensaios para verificação da adequação dos projetos das isolações dos equipamentos frente a sobretensões atmosféricas (1,2 / 50 microssegundos). É fato conhecido que a suportabilidade das isolações depende não só da amplitude como da forma de onda das solicitações. Diferentes modelos têm sido propostos para se estimar o desempenho das isolações frente a impulsos não normalizados, sendo o modelo do efeito disruptivo (disruptive effect model) um dos mais utilizados. Existem, contudo, diferentes métodos de aplicação desse modelo, ou seja, diferentes formas de se estimar os parâmetros necessários para a sua aplicação. Este trabalho visa avaliar o comportamento dielétrico de isoladores de média tensão e analisar os principais métodos para estimativa da suportabilidade desses equipamentos frente a sobretensões atmosféricas com formas de onda diferentes da normalizada. Para essa avaliação foram realizados ensaios em um isolador tipo pino, de porcelana, com tensão nominal de 15 kV, nos quais foram utilizadas, além do impulso atmosférico normalizado, outras ondas selecionadas com base em resultados de medição e de cálculo. Modificações realizadas no circuito de um gerador de impulsos de alta tensão convencional permitiram a geração de tensões com formas de onda bastante semelhantes às de sobretensões induzidas por descargas atmosféricas tanto em linhas de tamanho natural como em experimentos realizados com modelo reduzido. São apresentados e discutidos os resultados dos ensaios de tensão disruptiva de impulso atmosférico a 50 % e as curvas tensão-tempo (U x t) obtidas para cada impulso, considerando ambas as polaridades. A avaliação dos métodos de aplicação do modelo do efeito disruptivo foi realizada com base em comparações entre as curvas tensão-tempo obtidas nos ensaios e as curvas previstas por cada modelo, para cada uma das ondas selecionadas. / Overhead distribution lines are often exposed to lightning overvoltages, whose waveshapes vary widely and can differ substantially from the standard impulse voltage waveshape used to test electric equipment insulation against lightning surges (1.2 / 50 microseconds wave). It is well known that the voltage withstand capability of insulation depends not only on the amplitude but also on the voltage waveshape. Different models have been proposed for predicting the strength of insulation subjected to impulses of non-standard waveshapes. One of the most commonly used is the \"disruptive effect model\". There are, however, different methods of applying this model, that is, different ways of estimating the parameters needed for its application. This thesis aims at evaluating the dielectric behavior of medium voltage insulators subjected to impulses of non-standard waveshapes, as well as at evaluating the main methods for predicting their dielectric strength against such impulses. For the analysis, tests were performed on a pin type porcelain insulator with rated voltage of 15 kV, using, besides the standard lightning impulse voltage waveshape, other s waveshapes selected based on the characteristics of measured and calculated lightning overvoltages. Modifications made to the circuit of a conventional impulse voltage generator allowed to obtain voltage waveshapes very similar to those of lightning-induced voltages measured in experiments conducted both in lines of natural size and in reduced model. The test results relative to the critical lightning impulse flashover voltage (U50) and the volt-time characteristics obtained for the positive and negative polarities of each waveshape are presented and discussed. The evaluation of the methods of determining the parameters of the disruptive effect model was based on comparisons between the volt-time curves obtained from the laboratory tests and those predicted by each method, for each of the selected voltage waveshapes.
86

"Jogo patológico: análise por neuroimagem, neuropsicológica e de personalidade" / Pathological gambling: neuroimaging, neuropsychology and personality analyses

Moreira, Daniel Fuentes 24 August 2004 (has links)
Há evidências de comportamentos associados à impulsividade e prejuízos de funções de lobo frontal, sobretudo das funções executivas, em jogadores patológicos. Na tentativa de melhor caracterizar o fenômeno do jogo patológico, este estudo teve por objetivo verificar a utilidade de diferentes medidas de personalidade, desempenho em testes neuropsicológicos e análise das estruturas, na discriminação entre amostras jogadores patológicos e voluntários normais. Foram avaliados, em dois estudos, 50 jogadores patológicos e 50 controles normais, pareados por sexo, idade e anos de escolaridade formal. A bateria de testes neuropsicológicos consistiu de testes clássicos e computadorizados, avaliando funções atencionais e executivas. A personalidade foi avaliada através de inventários de auto-preenchimento desenvolvidos a partir de diferentes referenciais teóricos. Os dados de neuroimagem foram obtidos através de exames de ressonância magnética e foram analisados através do método automático de morfometria baseada no voxel. As pontuações obtidas nos testes neuropsicológicos e os resultados das diferentes medidas de personalidade revelaram que jogadores patológicos apresentam disfunção executiva e exacerbação de traços impulsivos e compulsivos. Os achados de ressonância magnética indicaram menor volume do núcleo caudado à esquerda e maior volume das porções dorsolaterais do córtex pré-frontal esquerdo na amostra de jogadores em relação aos controles. Estes achados, associados à relação encontrada entre impulsividade e compulsividade com as porções posteriores e anteriores do giro cingulado, respectivamente e sub-regiões dos gânglios da base, indicam que jogadores patológicos apresentam falhas das circuitarias cerebrais implicadas na regulação do comportamento. / High impulsivity and neuropsychological deficits associated to frontal lobes, specifically executive dysfunction, are reported among pathological gamblers (PG). In order to better understand the pathological gambling phenomena, the aim of this study was to verity the ability of personality measures, neuropsychological tests and brain structures to discriminate a sample of pathological gamblers from a sample of normal volunteers. A two-study format was adopted evaluating 50 pathological gamblers matched to 50 healthy volunteers according to gender, age and years of formal education. The neuropsychological measures consisted of classic and computerized tests that evaluate attentional and executive functions. Personality traits were measured by self-report scales developed under different theoretical approaches. Neuroimage data were analyzed using an optimized Voxel-Based Morphometric protocol. The scores obtained on the neuropsychological tests and self-report inventories showed that pathological gamblers present executive dysfunction and high personality traits of impulsivity and compulsivity. The magnetic resonance imaging of pathological gamblers showed smaller caudate volume on the left hemisphere and larger prefontal dorsolateral areas on left frontal cortex than the control group. An association between posterior and anterior cingulated, basal ganglia sub regions and compulsivity and impulsivity was also found too. These data suggest that pathological gamblers have dysfunctional brain circuits implicated in behavioural regulation.
87

Modeling of the behavior of medium voltage insulators against lightning overvoltages / Modelagem do comportamento de isoladores de média tensão contra sobretensões de impulsos atmosféricos

Miltom Shigihara 05 October 2015 (has links)
Lightning causes important transient disturbances on transmission and distribution systems, with consequent damages to equipment, outages, and general decrease of the power quality. The assessment of the lightning dielectric strength of power equipment is generally based on tests performed using the standard lightning impulse voltage (1.2 / 50 µs waveshape), although the characteristics of the lightning overvoltages depend on many parameters and may vary widely. The behavior of insulators when subject to non-standard impulses depends both on the voltage amplitude and waveshape, and therefore a reliable model is required to produce the corresponding volt-time curves. Although there is no method universally accepted for this purpose, one of the most used is the Disruptive Effect (DE) model, which is based on the integration method concept. The application of this model involves the estimation of some parameters for which different procedures have been proposed in the literature, as for instance the procedures by Darveniza and Vlastos, by Hileman, by Chowdhuri et al., and by Ancajima et al. Tests of representative lightning overvoltages were performed to obtain the critical flashover overvoltages (CFO) and the volt-time curves of typical porcelain pin-type insulators considering three standard medium-voltage distribution classes (15 kV, 24 kV, and 36 kV) and five impulse voltage waveshapes, of both polarities. These tests provided data for the analyses of the insulators\' behavior and the results obtained using the different procedures for estimating the DE parameters. It is shown that in some cases insulator flashover is not predicted. A new method is then developed and proposed for evaluating the dielectric behavior of MV insulators. The method is validated using the typical insulators of the three voltage classes and the five lightning impulse voltages considered, of positive and negative polarities. The calculated volt-time curves showed in general a good agreement with the measured results for all the cases studied. The mean difference between the measured and calculated times to breakdown, for all the cases considered, was about 1.3 s; while the maximum difference was 4.0 s. The application of the proposed method to evaluate the occurrence of insulator flashovers in the shield wire line (SWL) system implemented in the State of Rondônia due to nearby lightning strikes supports previous conclusions that indicate that lightning has a significant impact on the SWL system performance in regions with high ground flash density. / Descargas atmosféricas produzem distúrbios transitórios significativos em sistemas de transmissão e distribuição, com consequentes danos em equipamentos, interrupções e redução geral na qualidade de energia elétrica. A avaliação da suportabilidade dielétrica frente às descargas atmosféricas do equipamento de potência é geralmente baseada em ensaios realizados usando o impulso atmosférico de tensão normalizada (forma de onda 1.2 / 50 µs), contudo as características das sobretensões atmosféricas dependem de muitos parâmetros e podem variar amplamente. O comportamento dos isoladores quando sujeitos a impulsos não normalizados depende tanto da magnitude como da forma de onda da tensão, e então um modelo confiável é necessário para se obter as curvas tensão-tempo correspondentes. Embora não haja um método universalmente aceito para essa finalidade, um dos mais utilizados é o modelo de Efeito Disruptivo (DE), que é baseado no conceito do método de integração. A aplicação desse modelo envolve a estimativa de alguns parâmetros para os quais diferentes procedimentos têm sido propostos na literatura, como por exemplo, os procedimentos de Darveniza e Vlastos, de Hileman, de Chowdhuri et al. e de Ancajima et al. Ensaios de sobretensões atmosféricas representativas foram feitos para obter as tensões de descarga disruptiva (CFO) e as curvas de tensão-tempo de isoladores de porcelana típicos, tipo pino, considerando três classes de tensão de distribuição de média tensão (15 kV, 24 kV e 36 kV) e cinco formas de onda de impulso de tensão, de ambas as polaridades. Estes ensaios proporcionaram dados para as análises do comportamento dos isoladores e os resultados obtidos usando os diferentes procedimentos para estimar os parâmetros necessários para a aplicação do modelo do Efeito Disruptivo. É mostrado que em alguns casos a disrupção no isolador não é prevista por tais procedimentos. Um novo método é, então, desenvolvido e proposto para avaliar o comportamento dielétrico dos isoladores de média tensão. O método é validado usando os isoladores típicos das três classes de tensão e as cinco formas de tensões de impulso atmosféricos consideradas, de polaridades positiva e negativa. As curvas tensão-tempo calculadas mostraram, em geral, boa concordância com os resultados medidos para todos os casos estudados. A diferença média entre os tempos de disrupção medidos e calculados, para todos os casos considerados, foi da ordem de 1,3 s; enquanto a máxima diferença foi de 4,0 s. A aplicação do método proposto para avaliar a ocorrência de disrupções em isoladores do Sistema de Cabo Para-raios Energizados (PRE), implementado no estado de Rondônia, devido a descargas atmosféricas indiretas, apoia as conclusões previamente obtidas que indicam que as descargas atmosféricas têm impacto significativo sobre o desempenho do sistema PRE em regiões com alta densidade de descargas para solo.
88

Identificação não-paramétrica de sistemas mecânicos usando filtros de Kautz / Non-parametric of mechanical systems identification using Kautz filters

Scussel, Oscar 04 March 2013 (has links)
Made available in DSpace on 2017-07-10T17:11:44Z (GMT). No. of bitstreams: 1 DISSERTACAO OSCAR SCUSSEL.pdf: 4301786 bytes, checksum: 8a64e99e73bc5e4478b9e5077d78baed (MD5) Previous issue date: 2013-03-04 / Impulse Response Functions (IRFs) are important in many engineering applications, mainly in structural dynamics and modal analysis involving experimental modal tests. These IRFs can be identified through several methods. Among these, the classical covariance method is one of the most used and it is based on the sum of convolution from the correlation functions between input and output signals known. However, this method is limited because it employs a large number of samples and has drawbacks related to over parametrization. In this sense, this work presentes and review the covariance method expanded in the ortonormal basis Kautz functions, because this alternative way allows to avoid these drawbacks. In order to ilustrate the procedure an algorithm with multiple objective functions to obtain the optimal poles of the Kautz filter is shown. The results are provided through three degree-of-freedom mechanical system simulated and experimental data in a beam to show the advantages, drawbacks, simplicity and efficiency of the proposed approach. / As funções de resposta ao impulso (IRFs) exercem papel de destaque na identificação de sistemas reais quando têm-se o conhecimento dos dados de entrada/saída do sistema. Essas IRFs são relevantes em muitas aplicações de Engenharia, especialmente em análise modal experimental de estruturas. Dentre os métodos para obtenção dessas IRFs, destaca-se o clássico método das covariâncias baseado na soma de convolução das funções de correlação entre os sinais de entrada e saída conhecidos. No entanto, esse método é limitado quando são coletadas muitas amostras e possui algumas desvantagens como efeitos de sobreparametrização. Neste sentido, este trabalho apresenta e revisa o método das covariâncias expandido na base ortonormal de Kautz para aplicações em identificação de sistemas mecânicos, pois essa forma alternativa permite evitar esses efeitos de sobreparametrização. Para obter os pólos ótimos dos filtros de Kautz, emprega-se um algoritmo multi-objetivo. Os resultados são verificados através de um sistema mecânico com três graus de liberdade e em dados experimentais a partir de uma viga na condição livre-livre no qual verificam-se as vantagens, desvantagens, simplicidade e eficiência do método proposto.
89

Lower Volatility, Higher Inequality: Are They Related?

Eksi, Ozan 29 June 2010 (has links)
This thesis is divided into three chapters. In the first chapter, I identify and explore the fundamental relationship between income inequality and GDP volatility. I give theoretical insight of this relationship alongside empirical evidence from a sample of industrialized countries. In the second chapter, in regression estimates relating inequality to the variables of interest, I suggest that rather than aggregate inequality, the average growth rate of within-cohort inequality data should be used. In the light of my findings I then try to explore the effect of international trade on inequality in the US and UK. In the last chapter, I carry out a Monte Carlo study. This compares efficiencies of impulse response matching and GMM estimators at identifying reduced form coefficients and structural parameters on a DSGE model. / Esta tesis está dividida por tres capítulos. En el primer capítulo, llevo al interés que hay una relación fundamental entre la desigualdad de ingresos y la volatilidad de PBI. Doy pruebas teóricas para esta relación, así como empíricas de una muestra de países industrializados. En el segundo capítulo, sugiero que mejor que la desigualdad agregada, la tasa de crecimiento media de dentro de desigualdades de cohorte debería estar usada en las estimaciones de regresión que relaciona la desigualdad con las variables del interés. Entonces trato de explorar el efecto del comercio internacional en la desigualdad en los EE.UU y en el Reino Unido a la luz de mis conclusiones. En el último capítulo, realizo un estudio de Monte Carlo para comparar la eficiencia de la Correspondencia de respuesta de Impulso y peritos GMM en la identificación de los coeficientes de forma reducidos y parámetros estructurales en un modelo de DSGE.
90

USO DA BASE DINÂMICA EM UM SISTEMA DE DUAS VIGAS ACOPLADAS / USING THE DYNAMIC BASIS IN A TWO BEAMS COUPLED SYSTEM

Seibel, Aline Brum 26 August 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work researches on free and forced vibrations of a double beam coupled system. The system is regarded as two Euler-Bernoulli beams which are parallel, have the same length, are simply supported and are connected through a viscoelastic layer. Natural frequencies and their mode shapes, also called eigenfunctions, of the coupled system are obtained through a uniform beam methodology which uses the free dynamical basis to represent the solution of the the modal equation. This study uses modal analysis and block matrix formulation, while the dynamical basis used to represent the modal solution is obtained from the dynamical solution of a fourth order differential equation whose coefficients are just those of the original problem. The natural frequencies and mode shapes of the undamped system are determined for several values of beam parameters. For the damped case, damping ratios of each beam and also of the viscoelastic layer (which characterizes the coupling the system) are considered. The forced response is represented using matrix impulse response, which is the solution of an initial value problem with impulsive initial conditions. / Neste trabalho é realizado um estudo sobre vibrações livres e forçadas de um sistema de dupla viga acoplado. O sistema é composto por duas vigas do tipo Euler-Bernoulli, paralelas, de mesmo comprimento, simplesmente apoiadas e conectadas por uma camada viscoelástica. São obtidas as frequências naturais e os modos de vibração ou autofunções do sistema acoplado utilizando uma metodologia para vigas uniformes, que usa a base dinâmica para escrever a solução da equação modal. O estudo é realizado através da análise modal e de uma formulação matricial em blocos, e a base dinâmica usada para escrever a solução da equação modal é gerada pela solução dinâmica de uma equação diferencial de quarta ordem cujos coeficientes são os mesmos do problema considerado. As frequências naturais e os modos de vibração para o sistema não amortecido são determinados para vários valores dos parâmetros da viga. Para o caso amortecido, consideramos o amortecimento individual em cada viga e o amortecimento que compõe a camada viscoelástica o qual caracteriza o acoplamento no sistema. A resposta forçada do sistema é escrita em função da resposta impulso matricial que é solução de um problema de valor inicial com condições iniciais impulsivas.

Page generated in 0.063 seconds