11

Mitigating Risks Associated with Secondary Intravenous Infusions: An Empirical Evaluation of a Technology-based, Training-based, and Practice-based Intervention

Chan, Katherine Yin-Yee 21 November 2013 (has links)
Secondary infusions is a common method to deliver short infusions of intravenous (IV) drugs and fluids. Errors associated with this infusion method have led to patient safety concerns. This study's objective was to empirically evaluate interventions to mitigate secondary infusion risks. Three interventions, including a technology-based intervention (clamp detector on a smart pump), a training-based intervention (educational module), and a practice-based intervention (use of a separate pump for short infusions), were tested in a simulated inpatient unit. The technology-based intervention significantly decreased secondary clamp errors whereas the training-based intervention reduced complex pressure differential errors. The practice-based intervention was the only intervention that significantly decreased both secondary clamp errors and pressure differential errors, but introduced new risks due to mismanagement of residual volume in IV tubing. Study results highlight the need for a combination of mitigation strategies and can help guide the selection of interventions to reduce secondary infusion errors.
12

Mitigating Risks Associated with Secondary Intravenous Infusions: An Empirical Evaluation of a Technology-based, Training-based, and Practice-based Intervention

Chan, Katherine Yin-Yee 21 November 2013 (has links)
Secondary infusions is a common method to deliver short infusions of intravenous (IV) drugs and fluids. Errors associated with this infusion method have led to patient safety concerns. This study's objective was to empirically evaluate interventions to mitigate secondary infusion risks. Three interventions, including a technology-based intervention (clamp detector on a smart pump), a training-based intervention (educational module), and a practice-based intervention (use of a separate pump for short infusions), were tested in a simulated inpatient unit. The technology-based intervention significantly decreased secondary clamp errors whereas the training-based intervention reduced complex pressure differential errors. The practice-based intervention was the only intervention that significantly decreased both secondary clamp errors and pressure differential errors, but introduced new risks due to mismanagement of residual volume in IV tubing. Study results highlight the need for a combination of mitigation strategies and can help guide the selection of interventions to reduce secondary infusion errors.
13

The understanding, perceptions and expectations of families of terminally ill patients on introducing the syringe driver in a palliative care unit

Wilkinson, Margaret Mary January 2013 (has links)
Thesis submitted in fulfilment of the requirements for the degree Master of Technology: Nursing In the Faculty of Health and Wellness Sciences At the Cape Peninsula University of Technology, 2013 / The syringe driver is a battery-operated device which accurately delivers a continuous subcutaneous infusion of a combination of medication to alleviate symptoms, such as pain, nausea and vomiting, noisy moist breathing and preterminal restlessness. The researcher who works in a palliative care unit in Cape Town noticed the ambivalence and negative attitudes from family members regarding the use of the syringe driver. This gave rise to distress, conflict and ambivalence in patients and between family members. This study aimed to gain insight into the understanding, perceptions and expectations of families of terminally ill patients commenced on a syringe driver in a palliative care unit. A descriptive, qualitative research method was employed using semi-structured interviews, diaries, observation and documentation as the data collection methods. Data was coded and arranged into themes. Thematic analysis and coding were used to analyse the data during this study. This study found that the lack of education and written information were the two major contributing factors towards negative attitudes causing ambivalence in family members whose relatives were on a syringe driver. This study also highlighted the need for quality improvement control when using the syringe driver in the palliative care unit. The need for continuous education and written information and support for the immediate and extendedfamily members was evident. KEY WORDS: Syringe driver, Symptom control, Family members, Terminally ill, Palliative care unit.
14

Estudo metrológico volumétrico de bombas de infusão peristálticas lineares / Volumetric metrological study of peristaltic linear infusion pump

Dumas Junior, Adair 18 August 2016 (has links)
O presente estudo consiste em analisar se o sistema atual de calibração das bombas de um determinado fabricante, baseado na entrada de parâmetros externos e consequente readequação interna por software é adequado para a correção dos volumes infundidos. A literatura carece de estudos sobre bombas de infusão peristálticas lineares, principalmente estudos metrológicos relacionados aos volumes infundidos. Esta carência relaciona-se entre outros fatores, pelos elevados custos das bombas de infusão, bem como à grande quantidade de horas de ensaios necessárias. Para isso, foram analisados os volumes infundidos em taxas mínima, intermediária e máxima de três bombas de infusão peristálticas lineares retiradas aleatoriamente de um hospital no estado do Paraná, que não passavam por manutenção havia exatos doze meses e estavam em uso contínuo no estabelecimento. Foram realizados ensaios em taxa fixa de 25 ml/h em 5 volumes diferentes ao longo da faixa habitual de uso. Também foram feitos ensaios em volume fixo de 10 ml variando-se a taxa de infusão entre 1 ml/h, 25 ml/h e 100 ml/h. Para análise estatística dos resultados, foi feito um teste de normalidade de Anderson-Darling, como a maioria dos resultados não apresentaram características de normalidade, foi feito uma análise do intervalo de confiança das medianas para análise dos resultados. Também foi necessário fazer uma ANOVA para verificação da influência das bombas e das taxas no volume infundido, seguido por uma análise de curva de erros e uma planilha para o cálculo de incertezas das medições. Foi possível verificar que os volumes infundidos pelas bombas deste fabricante, em sua maioria apresentaram mudanças significativas após o processo de calibração, com diminuição na variância e melhora na exatidão dos volumes programados. / This study examined whether the current system calibration of the pumps from a particular manufacturer, based on the input of external parameters and consequent internal readjustment by software, is suitable for the correction of infused volumes. The literature lacks studies on linear peristaltic pump infusion, especially metrological studies related to the infused volume. This deficiency relates among other factors, the high costs of infusion pumps as well as the large amount of hours required for testing. Therefore, the volumes were analyzed by infusing at minimum, intermediate and maximum rates of three linear peristaltic infusion pumps randomly taken from a hospital in the state of Paraná, which had not have maintenance in the latest 12 months and were in continuous use at the hospital. Assays were performed in flat rate of 25 ml / h in 5 different volumes over the usual range of use. Tests at a fixed volume of 10 ml varying the infusion rate at 1 ml/h, 25 ml/h and 100 ml/h were also made. For statistical analysis, an Anderson-Darling normality test was done, as most of the results did not show normal characteristics, an analysis of the confidence interval of the median for analysis of results was done. It was also necessary to do an ANOVA to check the influence of pumps and rates of infused volume, followed by a curve error analysis and a spreadsheet to calculate the measurements uncertainties. It was possible to verify that the volumes infused by the bombs from this manufacturer, at most, showed significant changes after the calibration process, decreasing variance and improving the accuracy of programmed volumes.
15

Estudo metrológico volumétrico de bombas de infusão peristálticas lineares / Volumetric metrological study of peristaltic linear infusion pump

Dumas Junior, Adair 18 August 2016 (has links)
O presente estudo consiste em analisar se o sistema atual de calibração das bombas de um determinado fabricante, baseado na entrada de parâmetros externos e consequente readequação interna por software é adequado para a correção dos volumes infundidos. A literatura carece de estudos sobre bombas de infusão peristálticas lineares, principalmente estudos metrológicos relacionados aos volumes infundidos. Esta carência relaciona-se entre outros fatores, pelos elevados custos das bombas de infusão, bem como à grande quantidade de horas de ensaios necessárias. Para isso, foram analisados os volumes infundidos em taxas mínima, intermediária e máxima de três bombas de infusão peristálticas lineares retiradas aleatoriamente de um hospital no estado do Paraná, que não passavam por manutenção havia exatos doze meses e estavam em uso contínuo no estabelecimento. Foram realizados ensaios em taxa fixa de 25 ml/h em 5 volumes diferentes ao longo da faixa habitual de uso. Também foram feitos ensaios em volume fixo de 10 ml variando-se a taxa de infusão entre 1 ml/h, 25 ml/h e 100 ml/h. Para análise estatística dos resultados, foi feito um teste de normalidade de Anderson-Darling, como a maioria dos resultados não apresentaram características de normalidade, foi feito uma análise do intervalo de confiança das medianas para análise dos resultados. Também foi necessário fazer uma ANOVA para verificação da influência das bombas e das taxas no volume infundido, seguido por uma análise de curva de erros e uma planilha para o cálculo de incertezas das medições. Foi possível verificar que os volumes infundidos pelas bombas deste fabricante, em sua maioria apresentaram mudanças significativas após o processo de calibração, com diminuição na variância e melhora na exatidão dos volumes programados. / This study examined whether the current system calibration of the pumps from a particular manufacturer, based on the input of external parameters and consequent internal readjustment by software, is suitable for the correction of infused volumes. The literature lacks studies on linear peristaltic pump infusion, especially metrological studies related to the infused volume. This deficiency relates among other factors, the high costs of infusion pumps as well as the large amount of hours required for testing. Therefore, the volumes were analyzed by infusing at minimum, intermediate and maximum rates of three linear peristaltic infusion pumps randomly taken from a hospital in the state of Paraná, which had not have maintenance in the latest 12 months and were in continuous use at the hospital. Assays were performed in flat rate of 25 ml / h in 5 different volumes over the usual range of use. Tests at a fixed volume of 10 ml varying the infusion rate at 1 ml/h, 25 ml/h and 100 ml/h were also made. For statistical analysis, an Anderson-Darling normality test was done, as most of the results did not show normal characteristics, an analysis of the confidence interval of the median for analysis of results was done. It was also necessary to do an ANOVA to check the influence of pumps and rates of infused volume, followed by a curve error analysis and a spreadsheet to calculate the measurements uncertainties. It was possible to verify that the volumes infused by the bombs from this manufacturer, at most, showed significant changes after the calibration process, decreasing variance and improving the accuracy of programmed volumes.
16

Regulação sanitária de produtos para a saúde no Brasil e no Reino Unido: o caso dos equipamentos eletromédicos.

Souza, Mara Clécia Dantas January 2007 (has links)
p. 1-290 / Submitted by Santiago Fabio (fabio.ssantiago@hotmail.com) on 2013-04-30T20:35:03Z No. of bitstreams: 1 3333333333333333.pdf: 2022341 bytes, checksum: 509258a28eae8740edd814fa04c095a7 (MD5) / Approved for entry into archive by Maria Creuza Silva(mariakreuza@yahoo.com.br) on 2013-05-04T17:41:44Z (GMT) No. of bitstreams: 1 3333333333333333.pdf: 2022341 bytes, checksum: 509258a28eae8740edd814fa04c095a7 (MD5) / Made available in DSpace on 2013-05-04T17:41:44Z (GMT). No. of bitstreams: 1 3333333333333333.pdf: 2022341 bytes, checksum: 509258a28eae8740edd814fa04c095a7 (MD5) Previous issue date: 2007 / Este estudo analisa a regulação sanitária de equipamentos eletromédicos no Brasil e no Reino Unido. Busca identificar e analisar as semelhanças e diferenças entre os dois regimes e discutir em que medida eles protegem a saúde da população dos riscos decorrentes desses equipamentos. Optou-se por realizar pesquisa qualitativa exploratória com coleta de dados através de entrevistas, observação participante e análise de documentos, tomando-se bombas de infusão como equipamentos traçadores. Utilizando-se a Teoria dos Grupos de Interesse e a abordagem cibernética, é possível concluir que ambos os regimes estão implantados sob o modelo corporatista bipartite, priorizando a participação apenas de dois grupos de interesse, reguladores e aqueles representantes do segmento regulado. Apesar de terem legislação diferente, quanto à organização, o funcionamento deles se dá de modo fragmentado, implicando ocorrência de falhas regulatórias dos tipos captura e atenuação da ação regulatória. Têm estruturados de modo diferente os instrumentos regulatórios, controle sobre a entrada de empreendimentos no mercado, certificação de conformidade, revisão de pré-comercialização, tecnovigilância, mas guardam certa semelhança, no que diz respeito ao elemento central da ação regulatória - o equipamento em si, e não o paciente. Não utilizam os instrumentos regulatórios de forma balanceada, parecendo dar prioridade às atividades que geram recursos orçamentários para o órgão regulador e evitam conflito com o segmento regulado. Como conseqüência, aparenta que a regulação sanitária de equipamentos eletromédicos no Brasil e no Reino Unido ainda está distante de atender às necessidades de proteção da saúde da população. Para que esse objetivo seja alcançado, faz-se necessário investir em medidas educativas, esclarecendo a população sobre os riscos desses produtos e fomentando sua participação na organização do regime de regulação de risco à saúde. / Salvador