• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 9
  • 8
  • 8
  • 8
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da infiltração bacteriana através da interface implante-conector protético sob aplicação de carga - avaliação in vitro pelo método DNA Checkerboard / Bacterial leakage along the implant-abutment interface after loading simulation. In vitro evaluation by DNA Checkerboard method

Nascimento, Cássio do 03 September 2010 (has links)
A passagem bacteriana através da interface entre implante e conector protético com a conseqüente colonização dos implantes tem sido relatada em diversos estudos na literatura. O objetivo deste estudo in vitro foi avaliar a passagem de espécies bacterianas da saliva humana para o interior dos implantes através da interface implante-conector protético após simulação de carga cíclica controlada. Foram avaliados 60 implantes de um sistema de 2 componentes e seus respectivos conectores protéticos, divididos em 3 grupos de acordo com o tipo de conexão utilizado: hexágono externo, hexágono interno e cone morse. Cada grupo foi dividido em 2 subgrupos (n=10), submetidos à aplicação de carga e controle. Previamente ao teste, amostras do interior dos implantes foram coletadas para servirem como controle negativo da contaminação. Os conectores foram adaptados aos implantes com um torque final de 20 Ncm, de acordo com a recomendação do fabricante. Os conjuntos foram imersos em saliva humana e submetidos a 500.000 ciclos de carga com uma força de 120 N ou incubados em 35°C durante 7 dias sem aplicação de carga (controle). A eventual contaminação do interior dos implantes foi avaliada após o período experimental usando o método DNA Checkerboard. Microrganismos foram encontrados no interior dos implantes de todos os tipos de conexões avaliadas após o teste de carga cíclica. Os grupos cone morse apresentaram os menores valores de contagem bacteriana nos grupos submetidos a ciclagem de carga e controle. Os implantes submetidos à carga cíclica apresentaram maiores valores de contagem bacteriana do que seus respectivos controles no hexágono externo e interno. Nenhuma espécie bacteriana foi encontrada abrigando o interior dos implantes antes do teste de contaminação (controle negativo). Os implantes do grupo cone morse apresentaram menores quantidades de microrganismos nas duas condições testadas. Pode-se concluir que espécies bacterianas provenientes da saliva humana podem penetrar através da interface implante-conector protético com ou sem a simulação de carga cíclica, e que a aplicação de carga contribuiu para o aumento da contaminação nos implantes com conexão hexagonal externa e interna. / Bacterial leakage along the implant-abutment interface with consequent species harboring the inner parts of two-part dental implant systems has been reported. The aim of this in vitro study was to evaluate the bacterial leakage from human saliva to the internal part of the implants along the implant-abutment interface under loading conditions. Sixty dental implants, 20 for each external or internal hexagon and morse cone connection, and their conical abutments were used in this study. Each connection was sub-divided in 2 groups (n=10), loaded implants and control (unloaded). Previously to the bacterial leakage test, samples from the inner parts of the implants were collected with sterile microbrushes as negative control of contamination. The abutments were tightened to 20 Ncm on the implants. The assemblies were immersed in human saliva and loaded with 500,000 cycles of 120 N in experimental or incubated for 7 days at 35°C in control group. After this period, possible contamination of the internal parts of the implants was evaluated using the DNA Checkerboard method. Microorganisms were found in the internal surfaces of all connections evaluated. Morse cone connection presented the lowest count of microorganisms in control and loading group. Loaded implants present higher counts of microorganisms than control group in external and internal hexagon. No microorganisms were found in the samples recovered from the implants before contamination test (negative control). It can be concluded that bacterial species from human saliva may penetrate along the implant-abutment interface under unloaded and loaded conditions, and morse cone connection presented the lowest count of microorganisms.
2

Avaliação da infiltração bacteriana através da interface implante-conector protético sob aplicação de carga - avaliação in vitro pelo método DNA Checkerboard / Bacterial leakage along the implant-abutment interface after loading simulation. In vitro evaluation by DNA Checkerboard method

Cássio do Nascimento 03 September 2010 (has links)
A passagem bacteriana através da interface entre implante e conector protético com a conseqüente colonização dos implantes tem sido relatada em diversos estudos na literatura. O objetivo deste estudo in vitro foi avaliar a passagem de espécies bacterianas da saliva humana para o interior dos implantes através da interface implante-conector protético após simulação de carga cíclica controlada. Foram avaliados 60 implantes de um sistema de 2 componentes e seus respectivos conectores protéticos, divididos em 3 grupos de acordo com o tipo de conexão utilizado: hexágono externo, hexágono interno e cone morse. Cada grupo foi dividido em 2 subgrupos (n=10), submetidos à aplicação de carga e controle. Previamente ao teste, amostras do interior dos implantes foram coletadas para servirem como controle negativo da contaminação. Os conectores foram adaptados aos implantes com um torque final de 20 Ncm, de acordo com a recomendação do fabricante. Os conjuntos foram imersos em saliva humana e submetidos a 500.000 ciclos de carga com uma força de 120 N ou incubados em 35°C durante 7 dias sem aplicação de carga (controle). A eventual contaminação do interior dos implantes foi avaliada após o período experimental usando o método DNA Checkerboard. Microrganismos foram encontrados no interior dos implantes de todos os tipos de conexões avaliadas após o teste de carga cíclica. Os grupos cone morse apresentaram os menores valores de contagem bacteriana nos grupos submetidos a ciclagem de carga e controle. Os implantes submetidos à carga cíclica apresentaram maiores valores de contagem bacteriana do que seus respectivos controles no hexágono externo e interno. Nenhuma espécie bacteriana foi encontrada abrigando o interior dos implantes antes do teste de contaminação (controle negativo). Os implantes do grupo cone morse apresentaram menores quantidades de microrganismos nas duas condições testadas. Pode-se concluir que espécies bacterianas provenientes da saliva humana podem penetrar através da interface implante-conector protético com ou sem a simulação de carga cíclica, e que a aplicação de carga contribuiu para o aumento da contaminação nos implantes com conexão hexagonal externa e interna. / Bacterial leakage along the implant-abutment interface with consequent species harboring the inner parts of two-part dental implant systems has been reported. The aim of this in vitro study was to evaluate the bacterial leakage from human saliva to the internal part of the implants along the implant-abutment interface under loading conditions. Sixty dental implants, 20 for each external or internal hexagon and morse cone connection, and their conical abutments were used in this study. Each connection was sub-divided in 2 groups (n=10), loaded implants and control (unloaded). Previously to the bacterial leakage test, samples from the inner parts of the implants were collected with sterile microbrushes as negative control of contamination. The abutments were tightened to 20 Ncm on the implants. The assemblies were immersed in human saliva and loaded with 500,000 cycles of 120 N in experimental or incubated for 7 days at 35°C in control group. After this period, possible contamination of the internal parts of the implants was evaluated using the DNA Checkerboard method. Microorganisms were found in the internal surfaces of all connections evaluated. Morse cone connection presented the lowest count of microorganisms in control and loading group. Loaded implants present higher counts of microorganisms than control group in external and internal hexagon. No microorganisms were found in the samples recovered from the implants before contamination test (negative control). It can be concluded that bacterial species from human saliva may penetrate along the implant-abutment interface under unloaded and loaded conditions, and morse cone connection presented the lowest count of microorganisms.
3

Idealização e desenvolvimento de um dispositivo para avaliação de resistência da interface implante-intermediário protético por meio de ensaios cíclicos de flexão rotativa / Idealization and development of a device for evaluating resistance of implantabutment interface through rotary bending cyclic test

Ferreira, Felipe Ramalho 08 April 2010 (has links)
O sucesso da terapia reabilitadora com implantes requer um equilíbrio entre fatores biológicos e mecânicos. Os fatores biológicos são inúmeros, já os mecânicos associam-se à instabilidade da interface implante-intermediário protético. Com base nestas informações, este estudo busca criar um aparelho com o qual será possível avaliar e comparar a resistência e a estabilidade da interface implante-intermediário protético em implantes de diferentes tipos de sistema de conexão e componentes protéticos, após a aplicação de carga simulada, que será realizada por meio de um ensaio dinâmico de fadiga rotacional, também conhecido como flexão rotativa. Para a criação deste aparelho, vários procedimentos com base em princípios de usinagem CNC (Controle Numérico Computadorizado), engenharia elétrica e física foram utilizados. Os futuros testes e resultados, utilizando-se esse aparelho para realizar o ensaio de fadiga, serão publicados em trabalhos futuros. Para o desenvolvimento dos modelos de corpos de prova a serem analisados na máquina de ensaio, foram utilizados implantes do tipo hexágono externo (Neodent) de 3,75mm de diâmetro x 11.5mm de comprimento. Ao término do desenvolvimento, obteve-se um aparelho confiável, resistente e extremamente versátil; podendo-se facilmente variar a carga exercida e a frequência de rotação, sendo assim possível executar inúmeras combinações de ensaios de fadiga. Esse estudo demonstrou a possibilidade e viabilidade de desenvolver um aparelho adequado para realizar um ensaio de fadiga, de pequena dimensão (portátil) e a um custo significativamente inferior do que comprar um aparelho próprio para tal fim. / The success of a rehabilitation therapy with implant fixtures requires a balance between biological and mechanical factors. The biological factors are innumerable, however the mechanics associate it whit instability of the implant-abutment interface. On the basis of these information, the aim of this study is to create a device which it will be possible to evaluate and to compare the resistance and the stability of the implant-abutment interface whith implants of different connection system and abutments, after the simulated load application, that will be carried through a dynamic assay of rotational fatigue load, also known as rotary bending. For the creation of this device, some procedures on the basis of principles of milling CNC (Computerized Numerical control), electric and physical engineering had been used. The future tests and results, using this device to carry through the fatigue assay, will be published in future works. For the development of the body test to be analyzed in the assay machine, implant fixtures of external hexagon type (Neodent) of 3,75mm of diameter x 11mm of length had been used. In the ending of the development, a trustworthy, resistant and extremely versatile device was gotten; being able itself easily to vary the exerted load and the frequency of rotation, being been thus possible to execute innumerable combinations of fatigue assays. This study demonstrated the possibility and viability of it developing an adequate device to carry through an assay of fatigue, of small dimension (portable) and the significantly inferior cost of what if to buy a proper device for such end.
4

Ensaios mecânicos e estudo histológico da interface dos implantes vertebrais / Mechanical and histological studies of the vertebral screw interface

Vendrame, José Roberto Benites 26 September 2006 (has links)
A cirurgia da coluna vertebral tem se desenvolvido muito nos últimos anos em decorrência da evolução dos sistemas de fixação. O comportamento da interface do parafuso com o osso continua sendo um aspecto não muito dominado. Como o parafuso é a âncora de sustentação, o trabalho procura investigar as técnicas de introdução do parafuso pedicular. Para atingir esse objetivo desenvolvemos o trabalho por meio de estudo com ensaios mecânicos de arrancamento e estudo histológico. Dois tipos de parafusos pediculares foram utilizados: parafuso pedicular do sistema USIS (Ulrich) e parafuso pedicular do sistema USS (Synthes). Os ensaios de arrancamento foram realizados em corpos de prova de madeira e poliuretano. O estudo histológico foi realizado em vértebras lombares de cadáver humano. No estudo envolvendo o parafuso USIS, foram testados os seguintes parâmetros: orifícios feitos com sonda e orifícios feitos com broca, todos do mesmo diâmetro do diâmetro interno do parafuso. Também foi testado o efeito do macheamento em relação ao não macheamento, nos orifícios feitos com broca. No estudo com os parafusos USS foram testados o efeito do diâmetro do orifício piloto tanto no estudo histológico como no arrancamento. No arrancamento destes parafusos também foi testado o efeito do tipo de orifício feito com sonda e com broca. O trabalho foi dividido em etapas: Primeira etapa foi o estudo de arrancamento do parafuso USIS; segunda etapa, estudo histológico de vértebra instrumentada com parafuso USIS, esta parte do trabalho foi constituída por análise de microscopia de luz e microscopia eletrônica de varredura; terceira etapa foi o arrancamento do parafuso USS; e quarta etapa foi o estudo histológico de vértebra instrumentada com parafuso USS. Os resultados da primeira etapa demonstraram que sonda teve efeito melhor do que broca, porque o resultado dos ensaios de arrancamento nos orifícios feitos com sondas teve maior força de arrancamento do que nos orifícios feitos por brocas. Na segunda etapa, análise histológica, verificou-se que os orifícios feitos por sonda apresentaram-se menores e com menor índice de fragmentação ao redor dos orifícios. Esses feitos tiveram diferença estatística significante, tanto na primeira, quanto na segunda etapa. Com relação ao macheamento não foi constatada diferença entre o não macheamento, em nenhuma das duas etapas. Na terceira etapa foi observado que, quando o orifício piloto ultrapassa o diâmetro interno do parafuso, ocorre tendência de queda na força de arrancamento de modo significativo, enquanto que orifício menor que o orifício piloto não tende a causar muita diferença na força de arrancamento em relação ao orifício correspondente ao diâmetro interno do parafuso. Também foi observado que o orifício feito com sonda oferece melhor força de ancoragem do que orifício feito com broca. Na quarta etapa foi constatado que quanto menor a broca para abrir o orifício piloto, menor o diâmetro do orifício, e não houve diferença significativa quanto ao índice de fragmentação ao redor do orifício entre os diferentes tamanhos de broca. Como conclusão pode-se dizer que sonda é melhor para se fazer o orifício piloto, uma vez que alarga menos o orifício, lesa menos as trabéculas ao redor do orifício e proporciona maior força de ancoragem do que broca. Também se pode concluir que o instrumental de menor diâmetro para abertura do orifício piloto é melhor, e o ponto crítico seria o diâmetro interno do parafuso. Não se deve fazer orifício piloto com instrumento de diâmetro maior que o diâmetro interno do parafuso. Não se constatou vantagem em relação ao fato de realizar ou deixar de realizar o macheamento. / Spine surgery has developed a lot in the last years because of the evolution of the fixation system. The behavior of a screw in the bone is still unknown in many ways. Because the screw is the anchor of sustentation, this work tries to find the answers involving the pedicle screw fixation. To reach this objective we developed this work based on mechanical and histological studies. Two kinds of pedicle screws were used: pedicle screw of the USIS (Ulrich) and pedicle screw of the USS system (Synthes). The pullout tests were made in wood and polyurethane. The histological study was done in lumbar vertebra of humans. In the study about the USIS screw, the follow parameters were tested: hole done with probe and hole done with drill, all of the same inner diameter of the screw. The effect of tapping and not tapping the hole done with drill was tested. In the USS screw study, the effect of the diameter pilot hole in the pullout tests and its historical analysis was seen. In the pullout tests of these screws, both kind of holes done with probes and a drill were tested. The work was divided into stages; first stage was the study of the pullout of the USIS screw; second stage was two studies, a light-microscopic one and a sweeping-electronic-microscope one of the slides of the instrumented vertebra with USIS screws; third stage was the study of the USS screws pullout comparing the relationship between the diameter of the holes and the inner diameter of the screw together with the type of hole (drill and probe); fourth stage was light-microscopic histological study of the instrumented vertebras which had had USIS screws. Results of the first stage showed that probes were more efficient than drills because the mechanical tests of pullouts from probe-made-holes showed the need of the use of a stronger force. In the second stage, a light-microscopic analysis showed that probe-made-holes had a lesser minimum diameter and a lower index of fragmentation than drill-made holes. With relation to the tapping, there was no difference between the holes. Under electronic microscope sweeping, it was seen that probes betters compact the bone around the screw. In the third stage, it was seen that when 9 the pilot orifice was greater than the screws internal diameter a significantly lower force was needed for pullout, while when the pilot orifice was smaller it did not significantly increase the force needed. It was also seen that probe-made-holes had a better anchorage than the drill-made-holes. In the fourth stage, the histological analysis of the slides done with light-microscopy showed that the smaller the diameter of the drill the smaller minimum diameter; there was no significant difference between fragmentation indexes. Conclusion: Probes are better than drills to make a pilot hole because they cause less damage to the surrounding bone and give a stronger anchorage for the screw; the smaller the instrument used to make the pilot hole, better will be the strength of the screws anchorage; the critical point which the hole must not exceed is the internal diameter of the screw. Tapping, or not, makes no difference to the anchorage.
5

Estudo da Participação do Osso Cortical e Esponjoso na Fixação de Implante Pedicular na Coluna Lombar. / Mechanical and histological studies of the vertebral screw interface

Vendrame, José Roberto Benites 28 April 2000 (has links)
Foi realizado estudo experimental com a finalidade de avaliar a participação do osso cortical e osso esponjoso dos pedículos vertebrais, na fixação dos parafusos pediculares. Foram utilizados 10 segmentos de coluna lombar de adultos, retirados durante autópsia. O diâmetro dos pedículos das vértebras de L1 a L5 foram avaliados, considerando o diâmetro total e o diâmetyro do osso esponjoso, tendo sido realizadas essas medidas por meio de tomografia computadorizada e medida direta. Os segmentos da coluna vertebral foram divididos em dois grupos para o estudo, sendo que cada grupo era formado por 5 conjuntos de segmentos da coluna lombar. No primeiro grupo a perfuração era realizada segundo os pontos de orientação utilizados nos procedimentos cirúrgicos ( faceta articular e processo transverso). No segundo grupo foi realizado corte transversal na porção média do pedículo, de modo que a perfuração e introdução dos parafusos no seu interior foram efetuados sob visão diereta. Após a perfuração dos pedículos utilizando-se broca de 3 mm, os parafusos eram introduzidos no interior do pedículo vertebral em ordem crescente de seus diâmetros, até que fosse observada alteração estrutural do pedículo, que eram avaliados por meio de medidas sucessivas, utilizando-se paquímetro e observação direta. Foram utilizados parafusos com diâmetro que variou de 3 a 12,5 mm, com progressão de 0,5 mm. Quando o diâmetro do parafuso excedia a resistência estrutural do pedículo, duas lesões foram observadas, a deformação plástica e o rompimento. No grupo I houve um número maior de deformação plástica, mas pelos cálculos estatísticos não houve diferença significativa entre os grupos. Os diâmetro tomográficos obtidos pela medida tomográfica e medida direta apresentaram-se diferentes e sem correlação entre si. No grupo II, como os parafuos foram introduzidos de modo mais centralizado, houve maior número de parafusos com diâmetro maior que o diâmetro do osso esponjoso, mas também não apresentou diferença entre os grupos, segundo avaliações estatísticas. Análise dos valores do diâmetro pedicular, diâmetro do osso esponjoso e do parafuso de maior diâmetro introduzido sem lesar o pedículo permitiu observar que a camada de osso cortical do pedículo foi pouco ocupada pelo parafuso em ambos os grupos. O valor médio da porcentagem do diâmetro do pedículo ocupado pelo parafuso no grupo I foi de 70,7% e no grupo II 75,34%. Foi observado que os parafusos, de um modo geral, apresentaram ancoragem principalmente na porção de osso esponjoso do pedículo vertebral, tendo sido pequena a porcentagem de osso cortical do pedículo vertebral utilizado para a sua ancoragem. / Spine surgery has developed a lot in the last years because of the evolution of the fixation system. The behavior of a screw in the bone is still unknown in many ways. Because the screw is the anchor of sustentation, this work tries to find the answers involving the pedicle screw fixation. To reach this objective we developed this work based on mechanical and histological studies. Two kinds of pedicle screws were used: pedicle screw of the USIS (Ulrich) and pedicle screw of the USS system (Synthes). The pullout tests were made in wood and polyurethane. The histological study was done in lumbar vertebra of humans. In the study about the USIS screw, the follow parameters were tested: hole done with probe and hole done with drill, all of the same inner diameter of the screw. The effect of tapping and not tapping the hole done with drill was tested. In the USS screw study, the effect of the diameter pilot hole in the pullout tests and its historical analysis was seen. In the pullout tests of these screws, both kind of holes done with probes and a drill were tested. The work was divided into stages; first stage was the study of the pullout of the USIS screw; second stage was two studies, a light-microscopic one and a sweeping-electronic-microscope one of the slides of the instrumented vertebra with USIS screws; third stage was the study of the USS screws pullout comparing the relationship between the diameter of the holes and the inner diameter of the screw together with the type of hole (drill and probe); fourth stage was light-microscopic histological study of the instrumented vertebras which had had USIS screws. Results of the first stage showed that probes were more efficient than drills because the mechanical tests of pullouts from probe-made-holes showed the need of the use of a stronger force. In the second stage, a light-microscopic analysis showed that probe-made-holes had a lesser minimum diameter and a lower index of fragmentation than drill-made holes. With relation to the tapping, there was no difference between the holes. Under electronic microscope sweeping, it was seen that probes betters compact the bone around the screw. In the third stage, it was seen that when the pilot orifice was greater than the screws internal diameter a significantly lower force was needed for pullout, while when the pilot orifice was smaller it did not significantly increase the force needed. It was also seen that probe-made-holes had a better anchorage than the drill-made-holes. In the fourth stage, the histological analysis of the slides done with light-microscopy showed that the smaller the diameter of the drill the smaller minimum diameter; there was no significant difference between fragmentation indexes. Conclusion: Probes are better than drills to make a pilot hole because they cause less damage to the surrounding bone and give a stronger anchorage for the screw; the smaller the instrument used to make the pilot hole, better will be the strength of the screw\'s anchorage; the critical point which the hole must not exceed is the internal diameter of the screw. Tapping, or not, makes no difference to the anchorage.
6

Idealização e desenvolvimento de um dispositivo para avaliação de resistência da interface implante-intermediário protético por meio de ensaios cíclicos de flexão rotativa / Idealization and development of a device for evaluating resistance of implantabutment interface through rotary bending cyclic test

Felipe Ramalho Ferreira 08 April 2010 (has links)
O sucesso da terapia reabilitadora com implantes requer um equilíbrio entre fatores biológicos e mecânicos. Os fatores biológicos são inúmeros, já os mecânicos associam-se à instabilidade da interface implante-intermediário protético. Com base nestas informações, este estudo busca criar um aparelho com o qual será possível avaliar e comparar a resistência e a estabilidade da interface implante-intermediário protético em implantes de diferentes tipos de sistema de conexão e componentes protéticos, após a aplicação de carga simulada, que será realizada por meio de um ensaio dinâmico de fadiga rotacional, também conhecido como flexão rotativa. Para a criação deste aparelho, vários procedimentos com base em princípios de usinagem CNC (Controle Numérico Computadorizado), engenharia elétrica e física foram utilizados. Os futuros testes e resultados, utilizando-se esse aparelho para realizar o ensaio de fadiga, serão publicados em trabalhos futuros. Para o desenvolvimento dos modelos de corpos de prova a serem analisados na máquina de ensaio, foram utilizados implantes do tipo hexágono externo (Neodent) de 3,75mm de diâmetro x 11.5mm de comprimento. Ao término do desenvolvimento, obteve-se um aparelho confiável, resistente e extremamente versátil; podendo-se facilmente variar a carga exercida e a frequência de rotação, sendo assim possível executar inúmeras combinações de ensaios de fadiga. Esse estudo demonstrou a possibilidade e viabilidade de desenvolver um aparelho adequado para realizar um ensaio de fadiga, de pequena dimensão (portátil) e a um custo significativamente inferior do que comprar um aparelho próprio para tal fim. / The success of a rehabilitation therapy with implant fixtures requires a balance between biological and mechanical factors. The biological factors are innumerable, however the mechanics associate it whit instability of the implant-abutment interface. On the basis of these information, the aim of this study is to create a device which it will be possible to evaluate and to compare the resistance and the stability of the implant-abutment interface whith implants of different connection system and abutments, after the simulated load application, that will be carried through a dynamic assay of rotational fatigue load, also known as rotary bending. For the creation of this device, some procedures on the basis of principles of milling CNC (Computerized Numerical control), electric and physical engineering had been used. The future tests and results, using this device to carry through the fatigue assay, will be published in future works. For the development of the body test to be analyzed in the assay machine, implant fixtures of external hexagon type (Neodent) of 3,75mm of diameter x 11mm of length had been used. In the ending of the development, a trustworthy, resistant and extremely versatile device was gotten; being able itself easily to vary the exerted load and the frequency of rotation, being been thus possible to execute innumerable combinations of fatigue assays. This study demonstrated the possibility and viability of it developing an adequate device to carry through an assay of fatigue, of small dimension (portable) and the significantly inferior cost of what if to buy a proper device for such end.
7

Ensaios mecânicos e estudo histológico da interface dos implantes vertebrais / Mechanical and histological studies of the vertebral screw interface

José Roberto Benites Vendrame 26 September 2006 (has links)
A cirurgia da coluna vertebral tem se desenvolvido muito nos últimos anos em decorrência da evolução dos sistemas de fixação. O comportamento da interface do parafuso com o osso continua sendo um aspecto não muito dominado. Como o parafuso é a âncora de sustentação, o trabalho procura investigar as técnicas de introdução do parafuso pedicular. Para atingir esse objetivo desenvolvemos o trabalho por meio de estudo com ensaios mecânicos de arrancamento e estudo histológico. Dois tipos de parafusos pediculares foram utilizados: parafuso pedicular do sistema USIS (Ulrich) e parafuso pedicular do sistema USS (Synthes). Os ensaios de arrancamento foram realizados em corpos de prova de madeira e poliuretano. O estudo histológico foi realizado em vértebras lombares de cadáver humano. No estudo envolvendo o parafuso USIS, foram testados os seguintes parâmetros: orifícios feitos com sonda e orifícios feitos com broca, todos do mesmo diâmetro do diâmetro interno do parafuso. Também foi testado o efeito do macheamento em relação ao não macheamento, nos orifícios feitos com broca. No estudo com os parafusos USS foram testados o efeito do diâmetro do orifício piloto tanto no estudo histológico como no arrancamento. No arrancamento destes parafusos também foi testado o efeito do tipo de orifício feito com sonda e com broca. O trabalho foi dividido em etapas: Primeira etapa foi o estudo de arrancamento do parafuso USIS; segunda etapa, estudo histológico de vértebra instrumentada com parafuso USIS, esta parte do trabalho foi constituída por análise de microscopia de luz e microscopia eletrônica de varredura; terceira etapa foi o arrancamento do parafuso USS; e quarta etapa foi o estudo histológico de vértebra instrumentada com parafuso USS. Os resultados da primeira etapa demonstraram que sonda teve efeito melhor do que broca, porque o resultado dos ensaios de arrancamento nos orifícios feitos com sondas teve maior força de arrancamento do que nos orifícios feitos por brocas. Na segunda etapa, análise histológica, verificou-se que os orifícios feitos por sonda apresentaram-se menores e com menor índice de fragmentação ao redor dos orifícios. Esses feitos tiveram diferença estatística significante, tanto na primeira, quanto na segunda etapa. Com relação ao macheamento não foi constatada diferença entre o não macheamento, em nenhuma das duas etapas. Na terceira etapa foi observado que, quando o orifício piloto ultrapassa o diâmetro interno do parafuso, ocorre tendência de queda na força de arrancamento de modo significativo, enquanto que orifício menor que o orifício piloto não tende a causar muita diferença na força de arrancamento em relação ao orifício correspondente ao diâmetro interno do parafuso. Também foi observado que o orifício feito com sonda oferece melhor força de ancoragem do que orifício feito com broca. Na quarta etapa foi constatado que quanto menor a broca para abrir o orifício piloto, menor o diâmetro do orifício, e não houve diferença significativa quanto ao índice de fragmentação ao redor do orifício entre os diferentes tamanhos de broca. Como conclusão pode-se dizer que sonda é melhor para se fazer o orifício piloto, uma vez que alarga menos o orifício, lesa menos as trabéculas ao redor do orifício e proporciona maior força de ancoragem do que broca. Também se pode concluir que o instrumental de menor diâmetro para abertura do orifício piloto é melhor, e o ponto crítico seria o diâmetro interno do parafuso. Não se deve fazer orifício piloto com instrumento de diâmetro maior que o diâmetro interno do parafuso. Não se constatou vantagem em relação ao fato de realizar ou deixar de realizar o macheamento. / Spine surgery has developed a lot in the last years because of the evolution of the fixation system. The behavior of a screw in the bone is still unknown in many ways. Because the screw is the anchor of sustentation, this work tries to find the answers involving the pedicle screw fixation. To reach this objective we developed this work based on mechanical and histological studies. Two kinds of pedicle screws were used: pedicle screw of the USIS (Ulrich) and pedicle screw of the USS system (Synthes). The pullout tests were made in wood and polyurethane. The histological study was done in lumbar vertebra of humans. In the study about the USIS screw, the follow parameters were tested: hole done with probe and hole done with drill, all of the same inner diameter of the screw. The effect of tapping and not tapping the hole done with drill was tested. In the USS screw study, the effect of the diameter pilot hole in the pullout tests and its historical analysis was seen. In the pullout tests of these screws, both kind of holes done with probes and a drill were tested. The work was divided into stages; first stage was the study of the pullout of the USIS screw; second stage was two studies, a light-microscopic one and a sweeping-electronic-microscope one of the slides of the instrumented vertebra with USIS screws; third stage was the study of the USS screws pullout comparing the relationship between the diameter of the holes and the inner diameter of the screw together with the type of hole (drill and probe); fourth stage was light-microscopic histological study of the instrumented vertebras which had had USIS screws. Results of the first stage showed that probes were more efficient than drills because the mechanical tests of pullouts from probe-made-holes showed the need of the use of a stronger force. In the second stage, a light-microscopic analysis showed that probe-made-holes had a lesser minimum diameter and a lower index of fragmentation than drill-made holes. With relation to the tapping, there was no difference between the holes. Under electronic microscope sweeping, it was seen that probes betters compact the bone around the screw. In the third stage, it was seen that when 9 the pilot orifice was greater than the screws internal diameter a significantly lower force was needed for pullout, while when the pilot orifice was smaller it did not significantly increase the force needed. It was also seen that probe-made-holes had a better anchorage than the drill-made-holes. In the fourth stage, the histological analysis of the slides done with light-microscopy showed that the smaller the diameter of the drill the smaller minimum diameter; there was no significant difference between fragmentation indexes. Conclusion: Probes are better than drills to make a pilot hole because they cause less damage to the surrounding bone and give a stronger anchorage for the screw; the smaller the instrument used to make the pilot hole, better will be the strength of the screws anchorage; the critical point which the hole must not exceed is the internal diameter of the screw. Tapping, or not, makes no difference to the anchorage.
8

Avaliação in vitro pelo método DNA-Checkerboard da eficácia de uma pasta antimicrobiana e da adição de sais de prata em pilares protéticos, no controle da contaminação bacteriana através da interface implante-conector / In vitro evaluation by DNA checkerboard method of the efficacy of an antimicrobial paste and addition of silver salts in prosthetic abutments for the control of bacterial contamination at the implant-connector interface

Fernandes, Flávio Henrique Carriço Nogueira 14 November 2012 (has links)
A odontologia reabilitadora moderna preconiza cada vez mais o uso de implantes dentais para a substituição de dentes ausentes. É sabido que micro-organismos presentes na cavidade oral, em especial os relacionados à doença periodontal, são responsáveis pelos maiores índices de insucesso dos implantes. Este trabalho estudou a ocorrência de infiltração bacteriana através da interface implante-conector protético de implantes Cone Morse (CM) e Hexágono Interno (HI) após a associação com uma pasta antimicrobiana ou a adição de sais de prata nos pilares. Foram utilizados 72 implantes odontológicos de titânio (PROSS® - Sistema de Implantes, Dabi-Atlante, Ribeirão Preto, Brasil), 36 com conexão do tipo hexágono interno e 36 com conexão do tipo cone-morse, divididos em grupos, da seguinte forma: Grupo Pasta Antimicrobiana- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos, Grupo Íons de Prata- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos e Grupo Controle- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos. Os implantes e os conectores protéticos foram retirados de suas embalagens para aplicação do torque final (20N/cm). Antes disso, em um dos grupos experimentais, uma camada da pasta antimicrobiana foi aplicada sobre a superfície interna dos implantes e conectores protéticos e seus respectivos parafusos. Os conjuntos implantes-conectores foram parcialmente imersos na solução de saliva humana em tubos de ensaio e incubados em estufa bacteriológica a 37°C durante 7 dias. Após esse período, amostras do conteúdo interno dos conjuntos implantes-conectores protéticos dos 3 grupos foram colhidas com o objetivo de detectar e quantificar os micro-organismos presentes, utilizando para isto, a técnica de hibridização com sondas de DNA genômico DNA Checkerboard. Os implantes de conexão do tipo cone morse apresentaram menores valores de contagem de bactérias quando comparados aos implantes hexágono interno no grupo Controle (p<0,001), já para o grupo Íons de prata e Pasta antimicrobiana, foi observado comportamento inverso, maiores valores de contagem de bactérias para os implantes Cone Morse. Comparando-se os implantes de mesma conexão, entre os 03 grupos examinados, as amostras dos implantes Cone Morse dos grupos Controle, Íons de prata e Pasta antimicrobiana apresentaram valor de contagens de micro-organismos em ordem crescente. Os implantes de conexão hexágonal interna dos grupos Controle apresentaram maiores valores de contagens de micro-organismos seguidos pelos implantes do grupo Pasta antimicrobiana e Íons de prata, respectivamente. A partir dos resultados obtidos pode-se concluir que houve a passagem dos 43 micro-organismos analisados in vitro através da interface implante/componente protético em ambos os sistemas avaliados. Para ambos os tratamentos (adição de sais de prata às paredes dos pilares protéticos e aplicação da pasta antimicrobiana no interior dos implantes) houve diminução da infiltração microbiana no interior daqueles sistemas de conexão do tipo Hexágono Interno. / The contemporary and modern dentistry has been preconized the use of dental implants for replacement of missing teeth. The micro-organisms presents in oral environment, particularly those related to periodontal disease, are responsible for the highest failure rates of dental implants. This study evaluated the occurrence of bacterial leakage through the abutmentimplant interface in Morse Taped (CM) and Hexagon Internal (HI) dental implants after the association with antimicrobial paste or addition of silver salts on the abutments. 72 titanium dental implants (Pross ® - Implant System, Dabi-Atlante, Ribeirão Preto, Brazil), 36 with internal hexagon connection type and 36 with cone-morse connection type, divided into groups as follows: group Antimicrobial Paste -12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors, group Ion Silver-12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors and Control Group-12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors. The implants and prosthetic connectors have been removed from their packaging for applying of final torque (20N/cm). Previously, in one experimental group, a layer of antimicrobial paste was applied on the inner surface of implants and prosthetic connectors. The sets connector/implants were partially immersed in human saliva solution in test tubes and incubated in bacteriological oven at 37°C for 7 days. Subsequently, samples of the contents of internal prosthetic sets implantconnectors of the 3 groups were collected to detect and quantify micro-organisms, through the DNA Checkerboard Hybridization Technique. The morse taper implants had significantly lower bacterial count compared to internal hexagon implants in the control group (p <0.001), while for the group of Silver Ion and antimicrobial Paste, we observed an inverse behavior, higher counts of micro-organisms for Morse taper implants. Comparing the same connection implants, among the 03 groups examined, samples of implants Morse Taper Control groups, Antimicrobial Paste and Silver ions exhibited values of counts of micro-organisms in ascending order. The internal hexagon implants of the Control group showed higher counts of microorganisms followed by Antimicrobial Paste and Silver Ions groups, respectively. The 43 species analyzed in vitro infiltrated through the interface implant / abutment in both systems evaluated; For both the treatments (adding silver salts in the abutments walls and applying of the antimicrobial paste within the implants) there was decreased microbial leakage through the interface connection for the internal hexagon dental implants
9

Avaliação comparativa da remodelação óssea periimplantar em implantes com junção cone-morse e hexágono externo: estudo clínico randomizado controlado, duplo cego, boca dividida

Pereira, Leandro Maruki 03 July 2015 (has links)
Introdução: Várias hipóteses, tais como a formação de espaço biológico, as reações inflamatórias devido à contaminação do microgap entre implante-pilar, e a concentração de tensões peri-implantares causando microdanos ao tecido ósseo, têm sido sugeridos para explicar a perda óssea peri-implantar no primeiro ano em função. No entanto, ainda não é bem compreendido em qual extensão o tipo de conexão pilar/implante pode influenciar o processo de remodelação óssea ao redor de implantes. Objetivo: avaliar parâmetros clínicos, bacteriológicos, e biomecânicos relacionados à perda óssea peri-implantar na região da crista óssea, comparando as conexões hexagonal externa (HE) e cone morse (CM). Materiais e Métodos: Doze pacientes com mandíbulas totalmente desdentados receberam quatro implantes Ø 3,8 x 13 mm implantes na região interforaminal da mandíbula, com o mesmo design, mas diferentes conexões protéticas (dois deles HE ou CM, colocadas aleatoriamente com base em um desenho de boca dividida) e uma prótese implanto-suportada com carregamento imediato. Os parâmetros clínicos (profundidade de sondagem, índice gengival modificado e espessura da mucosa peri-implantar,) foram avaliados em 4 sítios ao redor dos implantes, após um ano de acompanhamento. A distância a partir do topo do implante para o primeiro contato entre o osso-implante - IT-FBIC foi avaliada em radiografias periapicais digitais padronizadas realizadas a 1, 3, 6 e 12 meses de acompanhamento. Amostras da microbiota subgengival foram coletadas 1, 3 e 6 meses após o carregamento do implante. DNA foi extraído e usado para a quantificação de Tanerella Forsythia, Porphyromonas gingivalis, Actinobacillus Aggragatibacter, Prevotella intermedia e Fusobacterium nucleatum. Comparação entre vários períodos de observação foram realizadas utilizando medidas repetidas Análise de Variância (ANOVA, α =0,5), seguido de um teste post-hoc de Tukey, enquanto que as comparações com base em dois períodos foram feitas utilizando o teste t pareado. Além disso, os modelos de computador tomográficos base de elementos finitos (EF) foram realizadas, simulando cada um dos doze paciente em três condições de carga. Os resultados para o pico de tensão EQV no osso peri-implantar foram interpretados por meio de um modelo linear geral (ANOVA-three- Way, α=0,5). Resultados: A variação na perda óssea peri-implantar avaliada por meio de radiografias foi significativamente diferente entre os tipos de conexão (P <0,001). A média de IT-FBIC foi de 1,17 ± 0,44 mm para HE, e 0,17 ± 0,54 milímetros para CM, considerando-se todos os períodos avaliados. Todos os parâmetros clínicos não apresentaram diferenças estatisticamente significantes. Diferenças significativas microbiológicas não foram observadas entre os dois tipos de conexões. A maioria das amostras recolhidas tinham muito poucos agentes patogénicos, o que significa que estas regiões eram saudáveis do ponto de vista microbiológico. Na análise EF, um pico significativamente maior de tensão EQV (P = 0,005) foi encontrado para HE (média 3.438,65μ∑) em comparação com CM (média de 840,98 μ∑□. Conclusões: Variar o tipo de conexão protética irá resultar em diferentes padrões de remodelação óssea peri-implantar, independentemente das condições clínicas e microbiológicas. É mais provável que este fato seja atribuído à transmissão de carga através de diferentes conexões implante-pilar para o osso peri-implantar. Os resultados atuais sugerem que uma conexão cone morse seja mais eficiente para prevenir a perda óssea peri-implantar, em comparação com uma conexão de hexágono externo. / Background: Several theories, such as the biological width formation, the inflammatory reactions due to the implant-abutment microgap contamination, and the periimplant stress/strain concentration causing bone microdamage accumulation, have been suggested to explain early periimplant bone loss. However, it is yet not well understood to which extent the implant-abutment connection type may influence the remodeling process around dental implants. Aim: to evaluate clinical, bacteriological, and biomechanical parameters related to periimplant bone loss at the crestal region, comparing external hexagon (EH) and Morse-taper (MT) connections. Materials and methods: Twelve patients with totally edentulous mandibles received four custom made Ø 3.8 x 13 mm implants in the interforaminal region of the mandible, with the same design, but different prosthetic connections (two of them EH or MT, randomly placed based on a split-mouth design), and a immediate implant- supported prosthesis. Clinical parameters (periimplant probing pocket depth, modified gingival index and mucosal thickness) were evaluated at 6 sites around the implants, at a 12 month follow-up. The distance from the top of the implant to the first bone-to-implant contact – IT-FBIC was evaluated on standardized digital peri-apical radiographs acquired at 1, 3, 6 and 12 months follow-up. Samples of the subgingival microbiota were collected 1, 3 and 6 months after implant loading. DNA were extracted and used for the quantification of Tanerella forsythia, Porphyromonas gingivalis, Aggragatibacter actinomycetemcomitans, Prevotella intermedia and Fusobacterium nucleatum. Comparison among multiple periods of observation were performed using repeated-measures Analysis of Variance (ANOVA), followed by a Tukey post-hoc test, while two-period based comparisons were made using paired t- test. Further, 36 computer-tomographic based finite element (FE) models were accomplished, simulating each patient in 3 loading conditions. The results for the peak EQV strain in periimplant bone were interpreted by means of a general linear model (ANOVA). Results: The variation in periimplant bone loss assessed by means of radiographs was significantly different between the connection types (P<0.001). Mean IT-FBIC was 1.17±0.44 mm for EH, and 0.17±0.54 mm for MT, considering all evaluated time periods. All clinical parameters presented not significant differences. No significant microbiological differences could be observed between both connection types. Most of the collected samples had very few pathogens, meaning that these regions were healthy from a microbiological point of view. In FE analysis, a significantly higher peak of EQV strain (P=0.005) was found for EH (mean 3438.65 µ∑) compared to MT (mean 840.98 µ∑) connection. Conclusions: Varying implant-abutment connection type will result in diverse periimplant bone remodeling, regardless of clinical and microbiological conditions. This fact is more likely attributed to the singular loading transmission through different implant-abutment connections to the periimplant bone. The present findings suggest that Morse-taper connection is more efficient to prevent periimplant bone loss, compared to an external hexagon connection. / Dissertação (Mestrado)
10

Avaliação in vitro pelo método DNA-Checkerboard da eficácia de uma pasta antimicrobiana e da adição de sais de prata em pilares protéticos, no controle da contaminação bacteriana através da interface implante-conector / In vitro evaluation by DNA checkerboard method of the efficacy of an antimicrobial paste and addition of silver salts in prosthetic abutments for the control of bacterial contamination at the implant-connector interface

Flávio Henrique Carriço Nogueira Fernandes 14 November 2012 (has links)
A odontologia reabilitadora moderna preconiza cada vez mais o uso de implantes dentais para a substituição de dentes ausentes. É sabido que micro-organismos presentes na cavidade oral, em especial os relacionados à doença periodontal, são responsáveis pelos maiores índices de insucesso dos implantes. Este trabalho estudou a ocorrência de infiltração bacteriana através da interface implante-conector protético de implantes Cone Morse (CM) e Hexágono Interno (HI) após a associação com uma pasta antimicrobiana ou a adição de sais de prata nos pilares. Foram utilizados 72 implantes odontológicos de titânio (PROSS® - Sistema de Implantes, Dabi-Atlante, Ribeirão Preto, Brasil), 36 com conexão do tipo hexágono interno e 36 com conexão do tipo cone-morse, divididos em grupos, da seguinte forma: Grupo Pasta Antimicrobiana- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos, Grupo Íons de Prata- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos e Grupo Controle- 12 conjuntos implantes HI/conectores protéticos e 12 conjuntos implantes CM/conectores protéticos. Os implantes e os conectores protéticos foram retirados de suas embalagens para aplicação do torque final (20N/cm). Antes disso, em um dos grupos experimentais, uma camada da pasta antimicrobiana foi aplicada sobre a superfície interna dos implantes e conectores protéticos e seus respectivos parafusos. Os conjuntos implantes-conectores foram parcialmente imersos na solução de saliva humana em tubos de ensaio e incubados em estufa bacteriológica a 37°C durante 7 dias. Após esse período, amostras do conteúdo interno dos conjuntos implantes-conectores protéticos dos 3 grupos foram colhidas com o objetivo de detectar e quantificar os micro-organismos presentes, utilizando para isto, a técnica de hibridização com sondas de DNA genômico DNA Checkerboard. Os implantes de conexão do tipo cone morse apresentaram menores valores de contagem de bactérias quando comparados aos implantes hexágono interno no grupo Controle (p<0,001), já para o grupo Íons de prata e Pasta antimicrobiana, foi observado comportamento inverso, maiores valores de contagem de bactérias para os implantes Cone Morse. Comparando-se os implantes de mesma conexão, entre os 03 grupos examinados, as amostras dos implantes Cone Morse dos grupos Controle, Íons de prata e Pasta antimicrobiana apresentaram valor de contagens de micro-organismos em ordem crescente. Os implantes de conexão hexágonal interna dos grupos Controle apresentaram maiores valores de contagens de micro-organismos seguidos pelos implantes do grupo Pasta antimicrobiana e Íons de prata, respectivamente. A partir dos resultados obtidos pode-se concluir que houve a passagem dos 43 micro-organismos analisados in vitro através da interface implante/componente protético em ambos os sistemas avaliados. Para ambos os tratamentos (adição de sais de prata às paredes dos pilares protéticos e aplicação da pasta antimicrobiana no interior dos implantes) houve diminução da infiltração microbiana no interior daqueles sistemas de conexão do tipo Hexágono Interno. / The contemporary and modern dentistry has been preconized the use of dental implants for replacement of missing teeth. The micro-organisms presents in oral environment, particularly those related to periodontal disease, are responsible for the highest failure rates of dental implants. This study evaluated the occurrence of bacterial leakage through the abutmentimplant interface in Morse Taped (CM) and Hexagon Internal (HI) dental implants after the association with antimicrobial paste or addition of silver salts on the abutments. 72 titanium dental implants (Pross ® - Implant System, Dabi-Atlante, Ribeirão Preto, Brazil), 36 with internal hexagon connection type and 36 with cone-morse connection type, divided into groups as follows: group Antimicrobial Paste -12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors, group Ion Silver-12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors and Control Group-12 implants HI / prosthetic connectors and 12 implants CM / prosthetic connectors. The implants and prosthetic connectors have been removed from their packaging for applying of final torque (20N/cm). Previously, in one experimental group, a layer of antimicrobial paste was applied on the inner surface of implants and prosthetic connectors. The sets connector/implants were partially immersed in human saliva solution in test tubes and incubated in bacteriological oven at 37°C for 7 days. Subsequently, samples of the contents of internal prosthetic sets implantconnectors of the 3 groups were collected to detect and quantify micro-organisms, through the DNA Checkerboard Hybridization Technique. The morse taper implants had significantly lower bacterial count compared to internal hexagon implants in the control group (p <0.001), while for the group of Silver Ion and antimicrobial Paste, we observed an inverse behavior, higher counts of micro-organisms for Morse taper implants. Comparing the same connection implants, among the 03 groups examined, samples of implants Morse Taper Control groups, Antimicrobial Paste and Silver ions exhibited values of counts of micro-organisms in ascending order. The internal hexagon implants of the Control group showed higher counts of microorganisms followed by Antimicrobial Paste and Silver Ions groups, respectively. The 43 species analyzed in vitro infiltrated through the interface implant / abutment in both systems evaluated; For both the treatments (adding silver salts in the abutments walls and applying of the antimicrobial paste within the implants) there was decreased microbial leakage through the interface connection for the internal hexagon dental implants

Page generated in 0.1252 seconds