• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Magnetfält i kuvöser för för tidigt födda barn / Magnetic field in infant incubators for premature children

Lilliesköld, Elina January 2011 (has links)
Det har tidigare uppmärksammats att magnetfältsnivåerna kan vara relativt höga i kuvöser, framförallt på grund av den värmebädd som barnet ligger på. I epidemiologiska studier av barnleukemi och association till magnetfältsexponering har man funnit en antydan till överrisk bland för tidigt födda barn som legat i inkubatorer med höga magnetfältsnivåer. Man har även funnit påverkan på hjärtfrekvensvariabilitet hos barn som vårdats i kuvöser och här misstänker man förhöjda magnetfältsnivåer som en möjlig förklaring. Syftet med denna studie var att genom noggranna mätningar kartlägga lågfrekventa magnetfält i och kring två sorters kuvöser (Dräger 8000 IC och Giraffe OmniBed) samt kringutrustning till dessa. Vidare har långtidsregistreringar av magnetfältet utförts i båda kuvöstyperna. I den äldre kuvösmodellen, Dräger 8000 IC, uppmättes värden mellan 1.0 och 8.1 µT vid kartläggning av magnetfältet inne i kuvösen. De högsta värdena var lokaliserade ovanför värmeelementet, en bit från centrum av kuvösen. Magnetfältet i den nyare modellen, Giraffe OmniBed, varierade vid kartläggningen mellan 0.2 och 5.8 µT, där de högsta värdena uppmättes mot ena kortändan av kuvösen. Medelvärdet från långtidsregistreringarna i kuvöserna beräknades till 1.9 µT för Dräger-kuvösen och 0.2 µT för Giraffe-kuvösen. Medelvärden från långtidsregistreringarna användes även till att beräkna en medeldos för sju veckors heltidsvård av barn i kuvös, uttryckt i mikroteslatimmar. Medeldosen för Dräger blev för huvudet 2.9∙103 µT∙h och för resten av kroppen 2.4∙103 µT∙h. För Giraffe blev medeldosen för huvudet 4.4∙102 µT∙h och för resten av kroppen 2.7∙102 µT∙h. Långtidsregistrering av magnetfält i hemmiljö mättes också i ett äldre hus och i en nyare lägenhet för jämförelse. Medeldosen för sju veckor i hemmiljö blev 10 – 60 µT∙h. Sammanfattningsvis kan man konstatera att magnetfälten i den nyare kuvösen (Giraffe OmniBed) var betydligt lägre än för den äldre kuvösmodellen (Dräger 8000 IC), men är fortfarande något förhöjda jämfört med normal hemmiljö. / It has previously been observed that the magnetic fields in infant incubators can be relatively high, particularly due to the heating bed the child is lying on. In epidemiologic studies of childhood leukaemia in association with exposure to magnetic fields, an inclination to excess risk has been found amongst premature children that have been lying in infant incubators with high magnetic field levels. Influence on the heart rate variability has also been found in children that have been treated in incubators, where elevated magnetic field levels are seen as a possible explanation. The purpose of this study was to map the magnetic field exposure in two different infant incubators (Dräger 8000 IC and Giraffe OmniBed) and the peripheral equipment. Furthermore, the magnetic field was logged over time in both incubator models. In the older model, Dräger 8000 IC, magnetic field levels between 1.0 µT and 8.1 µT were measured during the mapping of the magnetic field distribution over the bed. The highest value was localized above the heater, a short distance from the centre of the bed. The magnetic field in the newer model, Giraffe OmniBed, varied between 0.2 µT and 5.8 µT during the mapping, where the highest value was localized towards one of the short ends of the incubator. The mean value from the long term registration was calculated to 1.9 µT for the Dräger incubator and 0.2 µT for the Giraffe incubator. The average magnetic field level from the long-term registrations was used to calculate a dose for the baby, expressed in microtesla hours. The average dose for seven weeks of full time treatment in an incubator was 2.9∙103 µT∙h for the head and 2.4∙103 µT∙h for the remaining body in the Dräger incubator. Corresponding values for the Giraffe incubator was 4.4∙102 µT∙h for the head and 2.7∙102 µT∙h for the body. Long-time registration in home environment was also conducted in an older house and in a newer apartment. The average dose for seven full weeks was then 10 – 60 µT∙h. The conclusion from all this is that the magnetic field levels in the newer incubator model (Giraffe OmniBed) was significantly lower than in the older model (Dräger 8000 IC) but still higher than in an average home environment.
2

The infant incubator from a hygienic and HTO perspective : Using ATP luminescence to identify problem areas and suggesting solutions / Kuvösen ur ett hygieniskt och MTO perspektiv : Identifiering av problemområden med ATP luminiscens och förslag till lösningar

Wikström, Stephanie, Huisman, Simon January 2014 (has links)
Healthcare associated infections (HCAI) are a major problem in healthcare today. Preterm infants have problems keeping their body temperature within normal boundaries due to heat-loss. They therefore need special care that is administered with the help of incubators, which help minimise the heat loss via convection. Within neonatology the incubator has been identified as one of the contributing factors to HCAI due to the warm and humid environment, making it easy to spread nosocomial flora. To assess if the incubator is a factor in the spreading of HCAI this project has focused on ATP+AMP (total ATP) luminescence measurements to find areas in the incubator that are likely to contribute to the spread of HCAI and suggesting solutions to some of these. Adenosine triphosphate (ATP) is found in both organic debris and bacteria and is therefore a good indicator of a problem area due to organic debris acting as nutrients. Only the incubator box of the Giraffe® OmniBed® incubator was studied. The cleaning process was observed on multiple occasions and together with interviews resulted in a number of 29 hypothesised problem areas, on or within the incubator box, that were measured before and after cleaning. The results show that incubators collect a substantial amount of total ATP during its use. Measurements also show that parts that are cleaned by a disinfector are cleaner than those parts that are cleaned manually. Areas on the main compartment became more contaminated after cleaning which further indicated that the design of the incubator needs improving. It was also concluded that there often was residue from soap left on the surface of the main compartment resulting in inhibition of the total ATP luminescence reaction. This resulted in unrealistic low values due to the inclusion of foam and soap in the sample and as a result 45 out of 570 measurements were excluded. Caution is advised when using the Kikkoman total ATP luminescence method, especially on the main body (chassis) of the incubator. A steam vapour cleaner and flask cleanser brush could be used to better reach and clean areas such as cavities and around the bed heating element. The use of the steam vapour cleaner could also diminish or eliminate the use of surface disinfectant that causes red irritated eyes and dizziness in the cleaning staff. The functionality of the incubator was found to be excellent but major improvements can be made in the incubator design to make the cleaning of the incubator easier. / Vårdrelaterade infektioner (VRI) är ett stort problem inom vården idag. För tidigt födda barn (prematurer) har problem att hålla sin kroppstemperatur inom normala gränser på grund av ökad värmeförlust. De behöver därför särskild vård som ges med hjälp av kuvöser, vilka bidrar till att minimera värmeförluster som sker via konvektion. Kuvösen som används inom neonatologin har identifierats som en av de bidragande faktorerna till VRI på grund av den varma och fuktiga miljön,  vilken gör det lätt för mikroorganismer att föröka sig. För att bedöma i vilken utsträckning kuvösen är en faktor i spridningen av VRI har detta examensarbete genomfört ATP+AMP (total ATP) luminiscens-mätningar för att på så vis möjliggöra identifieringen av problemområden i kuvösen samt presentera lösningar till en del av dessa. ATP återfinns i både organisk materia och bakterier och är därför en bra indikator på ett problemområde på grund av att organisk materia agerar som näringsämne för bakterier. Enbart kuvösboxen tillhörande Giraffe® OmniBed® kuvösen testades i denna studie. Rengöringsprocessen av kuvösen observerades vid ett flertal tillfällen. Tillsammans med intervjuer resulterade detta i 29 förmodade problemområden belägna på eller inne i kuvösboxen. Dessa ställen mättes före och efter rengöring. Studien utfördes på neonatalavdelningen på Karolinska sjukhuset i Solna. Mätningar visade att delar som rengörs med en diskdesinfektor är mindre kontaminerade än de delar som rengörs manuellt. Flertalet områden på karossen blev mer kontaminerade efter rengöring vilket indikerade att utformningen av kuvösen behöver förbättras. Det var ofta tvålrester kvar på ytan av karossen, vilket resulterade i hämning av total ATP luminiscens-reaktion. Detta ledde till orealistiskt låga värden och att 45 av 570 mätningar exkluderades. Försiktighet bör iakttas vid användning av total ATP luminiscens-metoden, med Kikkomans LuciPac Pen, då sannolikheten för tvålrester ökar vid mätningar på karossen i kuvösen.  En ångrengörare och flaskborste skulle kunna användas för att bättre nå och rengöra problemområden, såsom hålrum och runt värmeelementet i botten av chassit. Dessa redskap behöver dock utvärderas i framtida studier. Användningen av ångrengörare kan också minska eller eliminera användningen av ytdesinfektion, som orsakar röda irriterande ögon och yrsel hos städpersonal, om effektiviteten uppmätts hålla sjukhusets krav på renhet. Funktionaliteten hos kuvösen fanns vara utmärkt, men förbättringar behövs i utformningen av kuvösen för att möjligöra effektivare, lättare och bättre rengöring.

Page generated in 0.0182 seconds