• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 237
  • 2
  • Tagged with
  • 242
  • 150
  • 88
  • 83
  • 78
  • 72
  • 70
  • 54
  • 50
  • 34
  • 33
  • 32
  • 31
  • 31
  • 30
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Análise da interação entre núcleos estruturais e lajes em edifícios altos / Analysis of the interaction between shear/core walls and slab in high buildings

Sousa Junior, Edgard 02 July 2001 (has links)
É apresentado um estudo sobre a análise de edifícios altos enrijecidos com núcleos estruturais utilizando-se processos discretos. A ligação do núcleo estrutural com as lajes do pavimento do edifício é o ponto principal deste estudo. As vigas, pilares e lajes são analisados utilizando-se o Método dos Elementos Finitos. Os núcleos estruturais, que no presente estudo podem ser de seção aberta ou semifechada, são analisados pela teoria de flexo-torção é levado em consideração o empanamento do elemento do núcleo, dessa forma aparece o esforço denominado bimomento. O empenamento do núcleo estrutural é transferido para as lajes, ocorrendo alteração em sua distribuição de esforços. Para o cálculo da estrutura do edifício como um todo é utilizada a técnica de subestruturação em que o edifício é dividido em subestruturas formadas por um determinado número de andares. Os resultados da forma de cálculo pesquisada são comparados com modelos já desenvolvidos por outros autores. / This is a study about the analysis of tall buildings with shear/core walls using discrete processes. The joining of shear/core with slabs in tall buildings is the main subject of this work. The beams, columns and slabs are analyzed using the Finite Element Method. The building analysis is in 1st order. The shear/core walls, in this study, can present open or semi-closed cross section; they are analyzed by the theory of warping of beams of solid sections. In this theory we consider the warping of the core element, accounting for the bimoment. The warping of the core is transferred to the slabs, and the efforts in the slabs are altered. In order to calculate the building structure we are using the sub-structure technique, the building is divided in substructures created by a certain number of floors. The results of this research are compared with models developed by other authors.
182

Modelagem numérica de lajes mistas de aço e concreto em situação de incêndio / Numerical modelling of steel-concrete composite slabs in fire

Santos, Daniel Bomfim Rocha dos 12 May 2014 (has links)
As lajes mistas de aço e concreto consistem de um sistema estrutural formado por fôrmas de aço (chapas perfiladas) permanentes sobre a qual é lançado o concreto armado. Após a cura do concreto, esses elementos trabalham conjuntamente, garantindo o comportamento misto. Esse tipo de sistema é amplamente utilizado na construção civil brasileira, por propiciar diversas vantagens, como a não utilização de fôrmas de madeiras e escoras. Com a finalidade de avaliar o comportamento térmico, estrutural e termoestrutural acoplado desse tipo de sistema, foram desenvolvidos modelos numéricos em elementos finitos no pacote computacional TNO DIANA em duas etapas distintas. Na primeira etapa é feita uma análise térmica bidimensional, cujos campos térmicos na seção transversal da laje são calibrados por meio de resultados experimentais disponíveis na literatura, avaliando os principais parâmetros que influenciam na distribuição de temperatura na laje, como a emissividade resultante e a resistência térmica na interface aço/concreto. Nessa etapa também se desenvolve um pós-processador em Visual Basic 11.0 capaz de ler os campos térmicos gerados pelo DIANA e calcular o momento fletor plástico resistente em função do tempo de exposição ao fogo. Esses resultados são comparados com aqueles calculados de acordo o modelo de cálculo da ABNT NBR 14323:2013. A segunda etapa consiste no desenvolvimento de modelos numéricos tridimensionais para se avaliar o comportamento termoestrutural acoplado de lajes mistas simplesmente apoiadas. Nessa etapa, primeiramente se faz a validação e calibração dos modelos numéricos à temperatura ambiente, avaliando fatores como a simetria dos modelos e a resistência ao cisalhamento longitudinal na interface entre a fôrma de aço e o concreto. Posteriormente, se realiza a validação do modelo numérico em temperatura elevada por meio de resultados experimentais disponíveis na literatura, considerando os efeitos dos gradientes térmicos na degradação das propriedades mecânicas e na expansão térmica do aço e concreto. Após a calibração do modelo numérico tridimensional em temperatura ambiente e elevada, se realizam análises paramétricas considerando a influência da armadura positiva, da espessura fôrma de aço, da resistência à compressão do concreto, da altura da laje e do vão entre apoios, por meio da curva de incêndio padrão. Os resultados obtidos dos modelos numéricos tridimensionais são comparados com aqueles obtidos pelo método do momento fletor plástico, calculados por meio dos resultados dos modelos térmicos, e de acordo o modelo de cálculo da ABNT NBR 14323:2013. / Steel-concrete composite slabs consist on a structural system comprising of permanent steel sheeting on which reinforced concrete is cast. After the cure of concrete, these elements work in conjunction, ensuring the composite behavior. This structural system is widely used in Brazilian civil construction, especially for providing several advantages, such as no use of formwork and post shores. In order to assess thermal, structural and staggered flow-stress behavior of this structural system, finite elements numerical models were developed in software TNO DIANA in two distinct steps. In the first step a two-dimensional thermal analysis is carried out, whose thermal fields in the slab cross section are calibrated by experimental results available in the literature, evaluating the main parameters that affect the temperature distribution in the slab, as the resulting emissivity and thermal resistance in the steel/concrete interaction. In this stage is also developed a post-processor in Visual Basic 11.0, which is able to read the thermal fields generated by DIANA and calculate the plastic bending moment capacity versus fire exposure time. These results are compared with those calculated according to the ABNT NBR 14323:2013 calculation model. The second step consists in the development of three-dimensional numerical models to evaluate the staggered heat-flow behavior of simply supported composite slabs. In this step, first is done the calibration and validation of the numerical models at ambient temperature, assessing factors such as the symmetry of the models and the longitudinal shear resistance between steel sheeting and the concrete. Later, numerical models are validated in fire through experimental results available in the literature, considering the effects of thermal gradients in the degradation of the mechanical properties and thermal expansion of steel and concrete. After validation of the three-dimensional numerical models at ambient and elevated temperature, parametric analysis are performed considering the influence of sagging reinforcement, the thickness of steel sheeting, compressive strength of the concrete, the slab height and the span between supports, through standard fire curve. The bending resistance of tri-dimensional numerical models is compared with that obtained by the plastic theory, calculated through the results of two-dimensional thermal models, and according to ABNT NBR 14323:2013 calculation model.
183

Análise experimental de lajes lisas unidirecionais de concreto armado de alta resistência com metacaulim apoiadas em pilares retangulares e armadas à punção / Experimental analysis of flagstones flat unidirectional of armed concrete of high resistance with leaning metakaolin in rectangular pillars and armadas to the puncture

CARVALHO, Adonay Saráty de 02 March 2006 (has links)
Made available in DSpace on 2011-03-23T21:19:18Z (GMT). No. of bitstreams: 0 / Item created via OAI harvest from source: http://www.bdtd.ufpa.br/tde_oai/oai2.php on 2011-03-23T21:19:18Z (GMT). Item's OAI Record identifier: oai:bdtd.ufpa.br:118 / ADA - Agência de Desenvolvimento da Amazônia / Ten reinforced concret slabs were tested, using metakaolin and high strength concrete (cc f nearly 60 MPa), The slabs are submitted to central loading, with objective to analyze the influence of the rectangularity rate of the columms (min C CmÃx) and the stirrups in the increase of resistance. The inclined stirrups have used. The slabâs dimensions were (1.800 x 1.800 x 110) mm and the variables considered were the rectangularity rate of the columms and use the stirrups and distribution around the columm. Ultimate loads, deflections, fissure maps, ductility, concrete, stirrups and reinforcement strains and failure types. The experimental results are comparisons with other results of the codes. The numerical results are compared with experimental results. The experimental results indicate that increase of the rectangularity rate of the columms to make the shear forces concentrat around the colummâs ends, suggesting that the region the shear combat are most solicit. The inclinate stirrups have eficient increase in the resistance of the slab and to change the failure types in some slabs. Observed increases than 32% when the stirrups have to distribuite around the colummâs ends. The low capacity resist to flexion have limited the punching resistance. / Foram analisadas experimentalmente 10 (dez) lajes lisas de concreto dosado com metacaulim e concreto de alta resistência (fcc =60 MPa). submetidas a carregamento simétrico. objetivando analisar a influência da variação do índice de retangularidade dos pilares (CIII;{. mm = 1. 3 e 5) e de armaduras de cisa1harnento na resistência ao puncionamento das mesmas. As armaduras de cisalhamento foram constituídas por estribos abertos inclinados. As lajes tinham dimensões de (1.800 x 1.800 x 110) mm e as principais variáveis foram à variação do índice de retangularidade dos pilares e distribuição dos estribos inclinados em tomo dos mesmos. Analisou-se os resultados de cargas de ruptura. flechas. mapa de fissuração. ductilidade. deformações no concreto e nas armaduras de ftexão e cisalhamento, e os modos de ruptura atingidos. Os resultados experimentais foram comparados com os resultados estimados por diversas normas. São também apresentados os resultados obridos numericamente para as lajes ensaiadas e comparados com os resultados experimentais. Os resultados experimentais mostraram que o aumento do índice de retangularidade faz com que as forças cortantes se concentrem nas extremidades do pilar, o que sugere que nessa região as armaduras de combate ao pmtcionamento são mais solicitadas. Os estribos inclinados foram eficientes no aumento das cargas de ruptura e alteraram inclusive o modo de ruptura de algumas lajes. Observou-se ganhos de até 32% quando os estribos foram distribuídos em tomo das extremidades dos pilares. A baixa capacidade resistente à flexão limitou a resistência última.
184

Análise de estruturas tridimensionais de edifícios altos considerando a rigidez transversal à flexão das lajes / Three dimensional analysis of tall buildings considering the transverse bending stiffness of slabs

Dermival Paula Bezerra 24 July 1995 (has links)
Este trabalho apresenta o estudo do comportamento das estruturas tridimensionais de edifícios altos, sujeitos às ações verticais e laterais, considerando-se a rigidez transversal à flexão das lajes. A análise é feita pelo processo dos deslocamentos para todos elementos, onde emprega-se o Método dos Elementos Finitos na discretização das lajes e vigas em cada pavimento. O sistema estrutural não considera a presença dos núcleos estruturais, pilares ou pilares-parede submetidos à flexo-torção. As lajes também funcionam como diafragmas infinitamente rígidos em seu plano, sendo responsável pela compatibilidade dos deslocamentos correspondentes e pela transmissão das forças do vento aos pilares. Elaborou-se um programa de computador que automatiza o processo utilizado, e alguns exemplos são apresentados para comprovar sua validade. / This work presents a study about the behavior of three dimensional structures of tall buildings, subjected to vertical and lateral loads, considering the transverse bending stiffness of slabs. The analysis is done by stiffness method for all elements, and Finite Element Method is used in the discretization of slabs and beams of each floor. The structural system does not consider cores, columns or shearwalls that are subjected to warping effects. The slabs also act as diaphragms with an infinite stiffness in their plane, responsible displacements, for compatibility of the horizontal and so transmit the wind forces to the columns. A computer program is developed to get automatic the process utilized in the analysis, and some examples are presented to check its validity.
185

Análise do efeito da retangularidade dos pilares nos critérios normativos de dimensionamento à punção em lajes lisas de concreto armado / Analysis of the effect of rectangularity rate of the columns in normative criteria for sizing punching in reinforced concrete flat slabs

PAIVA, Odilson da Silva de 22 October 2013 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T13:05:15Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseEfeitoRetangularidade.pdf: 2760909 bytes, checksum: f7553da9a0e039bc587df51a11724a63 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-20T16:05:13Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseEfeitoRetangularidade.pdf: 2760909 bytes, checksum: f7553da9a0e039bc587df51a11724a63 (MD5) / Made available in DSpace on 2017-03-20T16:05:13Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseEfeitoRetangularidade.pdf: 2760909 bytes, checksum: f7553da9a0e039bc587df51a11724a63 (MD5) Previous issue date: 2013-10-22 / O sistema com lajes lisas que não dependem de vigamento apresenta sua resistência limitada pela resistência à punção, visto que a região da ligação laje-pilar é critica devido às cargas concentradas em torno dos pilares. A geometria dos pilares é um dos fatores de influência na distribuição de tensões da região de ligação laje-pilar afetando por sua vez no dimensionamento à punção de lajes lisas. Neste estudo foi realizada uma profunda coleta de dados que visa reunir em um único trabalho a maior quantidade possível de lajes englobando os maiores nomes no estudo de punção, nacionais e internacionais, apresentando um total de 131 lajes. Foi feita uma comparação entre os principais códigos normativos usados atualmente, Eurocode 2 (2004), NBR 6118 (2007), ACI 318 (2008) e CEB-FIP (2010). Os resultados experimentais foram confrontados com os obtidos teoricamente levando em consideração os efeitos do índice de retângularidade em lajes lisas de concreto armado sem armaduras de cisalhamento verificando a adequação, confiabilidade de cada recomendação, analisando as particularidades das regras e diretrizes de cada critério normativo. / The system with flat slabs that do not depend on framework of beam has limited resistance by the resistance to punching shear, since the region of the slab-column is critical due to concentrated loads around the columns. The geometry of the columns is one of the factors influencing the distribution of stresses in the region of slab-column connection affecting turn in sizing the punching shear in the flat slabs. In this study we performed a thorough data collection that aims to collect into a single job the greatest possible amount of slabs covering the biggest names in the study of national and international punch, featuring a total of 131 slabs. A comparison was made between the main normative codes currently used Eurocode 2 (2004), NBR 6118 (2007), ACI 318 (2008) and CEB-FIP (2010). The experimental results were compared with those obtained theoretically taking into account the effects of retangularidade rate index in flat slabs of reinforced concrete, without punching shear reinforcement checking the adequacy, trustworthiness of each recommendation, analyzing the particularities of the rules and guidelines of each normative criterion.
186

Análise experimental de lajes nervuradas de concreto armado com viga faixa de altura variável / Reinforced concrete ribbed slabs with wide beam of variable heigth

SACRAMENTO, Paulo Victor Prazeres 21 November 2014 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T13:12:09Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseExperimentalLajes.pdf: 3840982 bytes, checksum: 08cee5cb9f2a5595f2e1e61185b408af (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-21T14:41:08Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseExperimentalLajes.pdf: 3840982 bytes, checksum: 08cee5cb9f2a5595f2e1e61185b408af (MD5) / Made available in DSpace on 2017-03-21T14:41:08Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseExperimentalLajes.pdf: 3840982 bytes, checksum: 08cee5cb9f2a5595f2e1e61185b408af (MD5) Previous issue date: 2014-11-21 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / As lajes nervuradas têm sido largamente utilizadas nas edificações por apresentar diversas vantagens em sua execução e desempenho. A fim de se obter um bom dimensionamento deste tipo de laje é necessário garantir que os esforços sejam devidamente suportados, principalmente aqueles considerados críticos, os quais podem levar a estrutura ao colapso de forma brusca, como é o caso da punção que geralmente ocorre na ligação laje-pilar e do cisalhamento na região das nervuras. Com o objetivo de avaliar o comportamento das lajes nervuradas em função da variação da altura da viga faixa foram fabricadas quatro lajes nervuradas de concreto armado, sendo duas unidirecionais e duas bidirecionais. A taxa de armadura de flexão foi constante em todas as lajes. Todas as lajes foram quadradas de lado 2200 mm e espessura constante igual a 150 mm. A principal variável neste trabalho foi a variação na altura da viga faixa. Esta variação teve o objetivo de avaliar como tal variação pode influenciar o comportamento das nervuras, mesmo quando o limite de espaçamento entre estas últimas for assegurado. Além disso, verificar se a punção é uma possibilidade de ruptura para este caso. As estimativas na etapa de dimensionamento foram baseadas em três diferentes normas. Estas foram ACI 318 (2008), Eurocode 2 (2004) e NBR 6118 (ABNT, 2014). Estudos realizados com lajes nervuradas têm mostrado que as estimativas das normas de projeto são conservadoras. Além disso, as previsões normativas de dimensionamento podem induzir a resultados imprecisos quanto à resistência das lajes. Os resultados experimentais desta série de ensaios foram comparados com as recomendações normativas a fim de avaliar a precisão destas três normas, no que se referem às lajes nervuradas. Foram, ainda, construídos modelos computacionais a fim de verificar qual o comportamento das lajes quanto à distribuição das tensões tanto na ligação da viga faixa-pilar como na ligação viga faixa-nervuras. Os resultados das lajes mostraram que a ligação viga faixa-nervuras deve ser tratada de forma criteriosa por conta da diferença de rigidez que existe entre a região maciça e as nervuras. / The ribbed slabs have been widely used in the buildings it has several advantages in its execution and performance. In order to get a good design of this type of slab is necessary ensure that the stresses are properly supported, mainly those considered critical, which can lead the structure to the collapse suddenly, as is the case of punching in connection wide beam-column or of the shear in the region of the ribbed. In order to evaluate the punching strength of the slab-column connection and the shear strength of the ribs were manufactured four reinforced concrete ribbed slabs, two slabs one-way and two slabs two-way. The flexural reinforcement rate was constant in all slabs. All slabs were square of side 2200 mm and thickness equal to 150 mm. The main variable in this study was the change in height of the wide beam. This variation has to evaluate the performance of the ribs, even when the limit of spacing between them is ensured. Also, check if the punching is a possibility of rupture in this case. The estimates in this step design were based on three different standards. These were ACI 318 (2008), Eurocode 2 (2004) and NBR 6118 (ABNT, 2014). Studies with ribbed slabs have shown that the estimates of design standards are conservative. In addition, this predictions may lead to inadequate results for resistance slabs. The experimental results of this series of tests were compared to the standard recommendations in order to assess the accuracy of these three standards, which refer to the ribbed slabs. Were also built computational models in order to verify that the behavior of slabs as the stress distribution both in connection wide beam-column range as the beam connection wide beam-ribbed. The results showed that the slabs connection wide beam-ribs must be treated in a careful manner due to the difference in stiffness between the solid area and the ribs.
187

Análise de estruturas tridimensionais de edifícios altos considerando a rigidez transversal à flexão das lajes / Three dimensional analysis of tall buildings considering the transverse bending stiffness of slabs

Bezerra, Dermival Paula 24 July 1995 (has links)
Este trabalho apresenta o estudo do comportamento das estruturas tridimensionais de edifícios altos, sujeitos às ações verticais e laterais, considerando-se a rigidez transversal à flexão das lajes. A análise é feita pelo processo dos deslocamentos para todos elementos, onde emprega-se o Método dos Elementos Finitos na discretização das lajes e vigas em cada pavimento. O sistema estrutural não considera a presença dos núcleos estruturais, pilares ou pilares-parede submetidos à flexo-torção. As lajes também funcionam como diafragmas infinitamente rígidos em seu plano, sendo responsável pela compatibilidade dos deslocamentos correspondentes e pela transmissão das forças do vento aos pilares. Elaborou-se um programa de computador que automatiza o processo utilizado, e alguns exemplos são apresentados para comprovar sua validade. / This work presents a study about the behavior of three dimensional structures of tall buildings, subjected to vertical and lateral loads, considering the transverse bending stiffness of slabs. The analysis is done by stiffness method for all elements, and Finite Element Method is used in the discretization of slabs and beams of each floor. The structural system does not consider cores, columns or shearwalls that are subjected to warping effects. The slabs also act as diaphragms with an infinite stiffness in their plane, responsible displacements, for compatibility of the horizontal and so transmit the wind forces to the columns. A computer program is developed to get automatic the process utilized in the analysis, and some examples are presented to check its validity.
188

Lajes alveolares protendidas: cisalhamento em região fissurada por flexão / Prestressed hollow core slabs: shear in region fissured due to bending

Periotto, Bruna Catoia 21 June 2011 (has links)
Esta pesquisa teve como principal objetivo analisar o comportamento de lajes alveolares protendidas de uso corrente no Brasil (pequenas espessuras e alta protensão) quanto ao cisalhamento em região fissurada por ação do momento fletor, para diferentes situações: sem e com capa e com preenchimento parcial de alvéolos. Foi desenvolvido um estudo teórico com o emprego de equacionamentos analíticos disponíveis na literatura técnica, envolvendo as recomendações da norma brasileira NBR 6118:2003 (Projeto de Estruturas de Concreto), do ACI-318:2008 (Building code requirements for structural concrete) e da EN 1992-1-1 (2004) (Eurocode 2- Projeto de estruturas de betão Parte 1-1: Regras gerais e regras para edifícios). Foram feitas comparações com resultados experimentais obtidos a partir de inúmeros ensaios de lajes alveolares protendidas. As unidades ensaiadas nesta pesquisa foram disponibilizadas por quatro empresas brasileiras de intensa atividade no mercado, sendo analisadas as capacidades resistentes de diferentes tipos. Assim, foram realizados 96 ensaios, 31 para a determinação da capacidade resistente à flexão e 65, ao cisalhamento, sendo selecionados modelos de lajes com grande emprego no mercado brasileiro. A partir desses ensaios, foi possível entender melhor o comportamento das lajes alveolares protendidas produzidas no Brasil. Com as diversas análises, considerando os ensaios experimentais e um vasto estudo teórico quanto ao dimensionamento dessas lajes, verificou-se a adequabilidade de equações de diferentes normas. Assim, foi possível identificar o equacionamento que melhor representa o comportamento das peças produzidas no Brasil, considerando inclusive peculiaridades de comportamento, que apresentam diferenças constratantes com relação a unidades produzidas em outros países. A partir desses estudos, produziu-se um amplo memorial de cálculo, considerando as diversas tipologias de lajes estudadas, com o objetivo de contribuir de modo didático com os engenheiros de estrururas. Logo, com esta pesquisa, foi possível não somente melhorar o entendimento do comportamento de tais lajes alveolares, como também fornecer subsídios para a avaliação desses elementos, considerando as características específicas das lajes produzidas no Brasil e, assim, contribuir para a padronização do dimensionamento junto à norma brasileira NBR 14861 (Laje pré-fabricada - Painel alveolar de concreto protendido). / This work had as major objective to analyze the behavior of Brazilian prestressed hollow core slabs - small thickness and high level of prestressing - considering shear in a cracked region due to bending moment, for different design situations: without concrete topping, with concrete topping and with filling the voids. A theoretical study was developed with the use of analytical equations available in the technical literature, involving the recommendations of the Brazilian code NBR 6118:2003 (Design of concrete structures), ACI-318: 2008 (Building code requirements for structural concrete) and EN 1992-1-1 (2004) (Eurocode 2: Design of concrete structures - Part 1-1: General rules and rules for buildings), comparing experimental results from many prestressed hollow core slabs tests. The slabs tested in this study were provided by four different Brazilian companies with intense activity in the market, and the resistant capacity of different typologies was analyzed. Thus 96 tests were made, 31 to determine the bending capacity and 64 for the determination of shear strength, and were selected slab models from the Brazilian market that are highly employed. From these tests, it was possible a better understanding of the prestressed hollow core slabs behavior produced in Brazil. With several analysis considering the experimental tests and an ample theoretical study about the design of these slabs, the adequacy of different codes equations were verified. Thus, it was possible to identify the equations that best represent the behavior of elements produced in Brazil, also considering the behaviour peculiarities of these slabs that have contrasting differences, if compared with units produced in other countries. From these studies it was produced a large design manual, considering the various types of studied slabs, aiming to contribute in a didactic way to the structural engineers. So, with this research, it was possible not only to improve comprehension of the behavior of such prestressed hollow core slabs, as well as provide information for evaluation of these elements, considering the specific characteristics of the slabs fabricated in Brazil and thus to contribute with the standardization of the design in the Brazilian code NBR 14861 (Prefabricated slab - Prestressed concrete hollow core panel).
189

Recuperação de pavimentos antigos em madeira com lajes mistas madeira-betão

Cardoso, Luis Manuel Ribeiro January 2010 (has links)
Tese de mestrado integrado. Engenharia Civil. Especialização em Construções Civis. Faculdade de Engenharia. Universidade do Porto. 2010
190

Modelagem do comportamento estrutural estático e dinâmico de lajes nervuradas de concreto armado. / Modeling the static and dinamic structural behavior of reinforced concret slabs.

Marcelo Roberto Souza Leite 30 January 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Diversos pesquisadores têm estudado o comportamento e o emprego de lajes nervuradas de concreto armado em sistemas estruturais na engenharia civil que demonstrem viabilidade sob o ponto de vista técnico e econômico. Por esta razão, inúmeros trabalhos têm sido publicados nos últimos anos respaldados por testes experimentais e análises numéricas. Neste contexto, diversos tipos de sistemas estruturais de lajes nervuradas têm sido desenvolvidos. Assim sendo, o objetivo desta investigação é o de contribuir, no que tange ao estudo do comportamento estrutural estático e dinâmico de lajes nervuradas de concreto armado, tendo em mente o emprego destas em sistemas estruturais na engenharia civil. Este trabalho de pesquisa objetiva também o estudo da resposta dinâmica de lajes nervuradas de concreto armado, sob o ponto de vista de conforto humano, especialmente quando essas estruturas encontram-se submetidas a atividades humanas rítmicas. A definição das ações dinâmicas atuantes sobre os modelos estruturais foi feita com base em resultados experimentais, que consideram grupos de indivíduos desenvolvendo atividades rítmicas correspondentes à ginástica aeróbica (atividade sincronizada). São empregadas técnicas usuais de discretização, via método dos elementos finitos (MEF), por meio do programa de elementos finitos ANSYS. No presente modelo computacional, as vigas de bordo, nervuras e a laje de concreto armado são simuladas por elementos finitos de casca. Os resultados obtidos ao longo do estudo, em termos das acelerações de pico, são confrontados e comparados com os limites propostos por normas de projeto, sob o ponto de vista do conforto humano. Com base na análise dinâmica das lajes nervuradas investigadas foi possível verificar que as atividades humanas rítmicas podem vir a gerar valores de acelerações de pico elevados e que violam os critérios de conforto humano. Deste modo, foi observado que, as acelerações nos modelos estudados, podem atingir níveis elevados de vibração que comprometem o conforto dos usuários. / Several researchers have studied the use of reinforced concrete ribbed slabs in civil engineering structural systems that can be viable when the technical and economical point of view is considered. For this reason, a lot of papers were published in the last years based on the experimental and numerical analysis of this slab type. In this context, several slab systems were developed and the reinforced concrete ribbed slabs is present among them. This way, this dissertation investigated the static and dynamic structural behaviour of reinforced concrete ribbed slabs used in civil engineering structures. This research work investigated the dynamic response of reinforced concrete ribbed slabs when subjected to the human rhythmic activities, focusing human comfort criteria. The dynamic loads were obtained through experimental tests with individuals carrying out rhythmic activities corresponding to aerobics (stimulated activities). The computational models are developed based on usual mesh refinement techniques present in finite element method simulations (FEM), implemented in the ANSYS program. In this computational model the reinforced concrete ribbed slabs and beams are represented by shell elements. The numerical results, in terms of peak accelerations, are compared with recommended limits proposed by design codes, under the point of view of human comfort. The reinforced concrete ribbed slabs dynamic analysis indicated that the actions produced by human rhythmic activities could generate peak accelerations that surpass design criteria limits developed for ensuring human comfort. Hence it was observed that the acceleration in the models studied, can achieve high levels of vibration that compromise the comfort of users.

Page generated in 0.0629 seconds