• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 4
  • 4
  • 3
  • Tagged with
  • 27
  • 27
  • 8
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Development of MOCVD GaN Homoepitaxy for Vertical Power Electronic Device Applications

Zhang, Yuxuan 02 September 2022 (has links)
No description available.
22

Estudo comparativo entre a ceratectomia fotorrefrativa (PRK) e a ceratectomia subepitelial borboleta assistida a laser (LASEK borboleta) / Comparative study between photorefractive keratectomy (PRK) and butterfly laser-assisted subepithelial keratectomy (BLASEK)

Ghanem, Vinicius Coral 29 August 2007 (has links)
OBJETIVO: Avaliar comparativamente os resultados de duas técnicas de cirurgia refrativa de superfície com excimer laser, ceratectomia fotorrefrativa (PRK) e ceratectomia subepitelial borboleta assistida à laser (LASEKb). LOCAL: Hospital de Olhos Sadalla Amin Ghanem, Joinville, Santa Catarina, Brasil. MÉTODOS: Realizou-se um estudo prospectivo, randomizado e duplo-cego envolvendo 102 olhos de 51 pacientes. Cada paciente teve aleatoriamente um dos olhos operado com a técnica do PRK e o outro com LASEKb. Os pacientes foram acompanhados por 1 ano. RESULTADOS: Não houveram diferenças significativas entre os dois grupos na acuidade visual (AV) para longe, sem correção, (P = 0,5593). No 12o mês pós-operatório (PO), 98,04% dos olhos no grupo do PRK e 96,08% no grupo do LASEKb atingiram AV sem correção de 20/20. A previsibilidade, eficácia, segurança e estabilidade não apresentaram diferença estatisticamente significativa entre os grupos. O índice de segurança foi de 1 no PRK e 0,996 no LASEKb. Um olho do grupo do LASEKb perdeu uma linha de visão. A porcentagem de olhos que apresentou EE aos 12 meses na faixa de ±0,50 D foi de 94,1% no grupo do PRK e de 86,3% no grupo do LASEKb (P = 0,1883). Enquanto que na faixa de ±1,0 D foi de 100% no grupo do PRK e 98% no grupo do LASEKb (P = 0,3125). Não houve necessidade de reoperações. O tempo médio de cirurgia na técnica PRK foi de 304,86 + 58,77 segundos (aproximadamente 5 minutos) e na técnica LASEKb de 608,35 + 76,88 segundos (aproximadamente 10 minutos) (P < 0,001). O tempo médio de reepitelização no grupo do PRK foi de 4,35 ± 0,48 dias (variação, 4 a 5 dias) e no grupo do BLASEK foi de 4,75 ± 0,72 dias (variação, 4 a 6 dias) (P < 0,002). Os níveis de dor e o desconforto ocular PO não foram estatisticamente diferentes entre os grupos, entretanto houve uma tendência para menor dor no PRK (3,31 ± 4,09 vs 4,43 ± 4,27; P = 0,18). Houve uma redução estatisticamente significativa nos valores do teste de Schirmer em todas as avaliação PO, tanto no PRK (23,6 ± 8,1 vs 19,4 ± 10,1; P < 0,002) quanto no LASEKb (22,4 ± 8,7 vs 18,9 ± 9,7; P = 0,01), entretanto não houve diferença entre os grupos. A opacificação corneana (OC) PO foi pequena nos dois grupos. Somente no 1o mês foi observado diferença estatística entre os grupos, com maior intensidade da OC no grupo do LASEKb (0,18 ± 0,3881) quando comparado ao PRK (0,08 ± 0,2109) (P = 0,039936). A maior intensidade foi observada no 3o mês, com redução gradativa até o 12o mês. CONCLUSÃO: Dentro das condições deste estudo, conclui-se que o PRK e o LASEKb mostraram resultados semelhantes, exceto que o PRK apresentou menor tempo cirúrgico, reepitelização corneana mais rápida e menor OC no 30o PO. / PURPOSE: Comparatively evaluate the results of two techniques of surface excimer laser refractive surgery, photorefractive keratectomy (PRK) and butterfly laser-assisted subepithelial keratectomy (BLASEK). SETTING: Sadalla Amin Ghanem Eye Hospital, Joinville, Santa Catarina, Brazil. METHODS: This is a prospective, randomized and double-masked study including 102 eyes from 51 patients. Each patient was randomized to have one eye operated on with PRK and the other with BLASEK. Patients were followed for 1 year. RESULTS: There were no significant differences between the groups regarding uncorrected distant visual acuity (VA) (p= 0.5593). On the 12th post-operative (PO) month, 98.04% of the eyes in the PRK group and 96.08% in the BLASEK group reached uncorrected VA of 20/20. The predictability, efficacy, safety and stability did not present statically significant difference between groups. The safety index was of 1 for PRK and 0.996 for BLASEK. One eye of the BLASEK group lost one line on the 12th PO month. The percentage of the eyes that presented spherical equivalent at 12 months in the range of ±0.50 D was 94.1% in the PRK group and 86.3% in the BLASEK group (p = 0.1883). While in the range of ±1.0 D it was 100% in the PRK group and 98% in the BLASEK group (p = 0.3125). There were no retreatments. The mean surgical time was 304.86 + 58.77 seconds (approximately 5 minutes) in PRK and 608.35 + 76.88 seconds in BLASEK (approximately 10 minutes) (P < 0,001). The mean reepithelization time in the PRK group was 4.35 ± 0.48 days (range, 4 to 5 days), and in the BLASEK group was 4.75 ± 0.72 days (range, 4 to 6 days) (P < 0.002). Pain scores and ocular discomfort were not statistically different between groups, although there was a trend towards a lower pain level with PRK (3.31 ± 4.09 vs. 4.43 ± 4.27; P = 0.18). Schirmer test values were significantly reduced from preoperative levels through 12 months with both PRK (23.6 ± 8.1 vs. 19.4 ± 10.1; P < 0.002) and BLASEK (22.4 ± 8.7 vs. 18.9 ± 9.7; P = 0.01), however there was no difference between groups in any time point. Haze incidence was slight in both groups. Only in the 1st PO month statistical difference between the groups was observed, with higher intensity in the BLASEK group (0.18 ± 0.3881) when compared to the PRK (0.08 ± 0.2109) (p = 0.039936). The highest intensity was observed on the 3rd month, with gradual reduction until the 12th month. CONCLUSION: In the conditions of this study, it can be concluded that PRK and BLASEK showed similar results, except that PRK presented shorter surgical time, faster corneal reepithelization and less haze at 30th PO days.
23

Effet de la pré-vascularisation organisée par Bioimpression Assistée par Laser sur la régénération osseuse / Effect of prevascularization designed by Laser-Assisted Bioprinting on bone regeneration

Kérourédan, Olivia 11 March 2019 (has links)
Afin de résoudre la problématique des substituts osseux faiblement vascularisés, un des challenges majeurs en ingénierie tissulaire osseuse est de favoriser le développement précoce d’une microvascularisation. La reproduction du microenvironnement local et l’organisation cellulaire in situ sont des approches innovantes pour optimiser la formation osseuse. En Biofabrication, la Bioimpression Assistée par Laser (LAB) est une technologie émergente permettant l’impression de cellules et de biomatériaux avec une résolution micrométrique. L’objectif de ce travail était d’étudier l’effet de l’organisation de la pré-vascularisation par LAB sur la régénération osseuse. La station de bioimpression Novalase a été utilisée pour imprimer des motifs de cellules endothéliales sur un « biopaper » constitué de collagène et de cellules souches issues de la papille apicale. Les paramètres d’impression, densités cellulaires et conditions de recouvrement ont été optimisés afin de favoriser la formation d’un réseau microvasculaire avec une architecture définie in vitro. Ce modèle a ensuite été transposé in vivo, grâce à la bioimpression in situ de cellules endothéliales au niveau de défauts osseux critiques chez la souris, afin d’évaluer si la prévascularisation organisée par LAB permettait de promouvoir et contrôler spatialement le processus de régénération osseuse. Les résultats ont montré que la bioimpression permettait d’augmenter la densité de vaisseaux dans les défauts osseux et de favoriser la régénération osseuse. / In order to solve the issue of poorly vascularized bone substitutes, development of a microvasculature into tissue-engineered bone substitutes represents a current challenge. The reproduction of local microenvironment and in situ organization of cells are innovating approaches to optimize bone formation. In Biofabrication, Laser-Assisted Bioprinting (LAB) has emerged as a relevant method to print living cells and biomaterials with micrometric resolution. The aim of this work was to study the effect of prevascularization organized by LAB on bone regeneration. The laser workstation Novalase was used to print patterns of endothelial cells onto a « biopaper » of collagen hydrogel seeded with stem cells from the apical papilla. Printing parameters, cell densities and overlay conditions were optimized to enhance the formation of microvascular networks with a defined architecture in vitro. This model was then transposed in vivo, through in situ bioprinting of endothelial cells into mouse calvarial bone defects of critical size, to investigate if prevascularization organized by LAB can promote and spatially control bone regeneration. The results showed that bioprinting allowed to increase blood vessel density in bone defects and promote bone regeneration.
24

Alterações biomecânicas da córnea de suínos induzidas pela confecções de lamelas pediculadas de diferentes espessuras por laser de femtossegundo / Biomechanical changes after flap creation with different thicknesses with the femtosecond laser in swinish cornea

Fabricio Witzel de Medeiros 22 July 2011 (has links)
Objetivo: Investigar as alterações biomecânicas da córnea de suínos induzidas pela confecção de lamelas pediculadas de diferentes espessuras pelo laser de femtossegundo. Métodos: Para a formação dos dois grupos, 12 olhos de porcos foram usados: lamelas pediculadas de 100 e de 300 micrômetros confeccionadas pelo laser de femtossegundo. Cada olho foi submetido aos seguintes exames, antes da criação das lamelas: topografia por rasterstereography, Ocular Response Analyzer (ORA), tomografia do segmento anterior por coerência óptica para a avaliação paquimétrica corneal e das lamelas criadas e sistema de velocidade de onda (SVO), que mede a velocidade de propagação de ondas acústicas entre dois transdutores posicionados na superfície corneal antes e imediatamente, após a feitura da lamela. O primerio passo foi desenhado para o estudo das diferenças em relação à histerese corneal, fator de resistência corneal, mudanças na curvatura e velocidade de propagação de onda acústica entre córneas com lamelas finas e espessas. Posteriormente, as lamelas foram amputadas, e as medidas do sistema de velocidade de onda foram repetidas. Resultados: A média de espessura das lamelas ± desviopadrão (DP) foi de 108,5±6,9 (8,5% da espessura total) e 307,8±11,5 m (22,9% da espessura total), para os grupos de lamelas finas e espessas, respectivamente (p< 0,001). Histerese corneal e o fator de resistência corneal não apresentaram diferença estatística, após a criação de lamelas finas (p = 0,81 e p = 0,62, respectivamente). Histerese corneal foi significantemente mais baixa, depois da confecção de lamelas mais espessas (8,0±1,0 para 5,1±1,5 mmHg para medidas pré e pós-operatórias, respectivamente, p = 0,003, diminuição de 36,25%) e fator de resistência corneal também mostrou significante diminuição nesse grupo, após o procedimento cirúrgico; valores médios pré e pós-operatórios de 8,2±1,6 e 4,1±2,5 mmHg respectivamente (p= 0,007), diminuição de 50%. A ceratometria média simulada apresentou maiores valores, após a confecção das lamelas mais espessas em relação ao pré-operatório (ceratometria pré e pós-operatória de 39,5±1 D e 45,9±1,2 D, respectivamente, p= 0,003). Para o grupo de lamelas finas, não houve diferença estatisticamente significante (ceratometria pré e pós-operatória de 40,6±0,6 D e 41,4±1,0 D, respectivamente, p=0,55). Em relação ao Sistema de Velocidade de Onda, após a criação das lamelas e sua amputação, houve diminuição da velocidade de propagação acústica, embora na maior parte das posições não fosse estatisticamente significante. Conclusão: Nas condições experimentais estabelecidas por este estudo, a criação de lamelas de maior espessura pareceu exercer efeito mais relevante sobre a biomecânica da córnea de suínos / Purpose: To study the impact of programmed flaps at two different thicknesses on the biomechanical properties of the swine corneas. Methods: Twelve pig eyes were enrolled in this study and were formed two groups: 100m and 300 m flaps performed with the femtosecond laser. Each eye had the following procedure before the flap creation: raster photograph topographic maps, Ocular Response Analyzer (ORA), Optical Coherence Tomography to measure the pachymetry and flap thickness and Surface Wave Velocity system which is a prototype system that measures sonic wave propagation time between two transducers positioned on the corneal surface before and after flap creation. This first step was designed to investigate the differences in respect to corneal hysteresis, corneal resistance factor, curvature change and ultrasonic wave propagation between the groups with thinner and thicker flaps. After this initial procedure, flap amputation was performed and new measurements with the surface wave velocity system were taken again. Results: Measured flap thicknesses averaged 108.5±6.9 (8.5% of the total cornea) and 307.8±11.5 m (22.9% of the total cornea) for thin and thick flap groups, respectively (p< 0.001). Hysteresis and corneal resistance factor did not change significantly after flap creation in the thin flap group (p = 0.81 and p = 0.62, respectively). With thicker flaps, both parameters decreased significantly from 8.0±1.0 to 5.1±1.5 mmHg (p=0.003, reduction of 36.25%) and from 8.2±1.6 to 4.1±2.5 mmHg, respectively (p = 0.007), reduction of 50%. Simulated keratometry values increased in the thick flap group (from 39.5±1 D to 45.9±1.2 D, p=0.003) after flap creation and not in the thin flap group (from 40.6±0.6D to 41.4±1.0D, p= 0.55). Regarding surface wave velocity analysis, the surgical procedures induced lower values in some positions although most of them did not present statistically different results. Conclusion: In this experimental model, thicker flaps seemed to have a greater effect on the biomechanics of the swinish cornea
25

Alterações biomecânicas da córnea de suínos induzidas pela confecções de lamelas pediculadas de diferentes espessuras por laser de femtossegundo / Biomechanical changes after flap creation with different thicknesses with the femtosecond laser in swinish cornea

Medeiros, Fabricio Witzel de 22 July 2011 (has links)
Objetivo: Investigar as alterações biomecânicas da córnea de suínos induzidas pela confecção de lamelas pediculadas de diferentes espessuras pelo laser de femtossegundo. Métodos: Para a formação dos dois grupos, 12 olhos de porcos foram usados: lamelas pediculadas de 100 e de 300 micrômetros confeccionadas pelo laser de femtossegundo. Cada olho foi submetido aos seguintes exames, antes da criação das lamelas: topografia por rasterstereography, Ocular Response Analyzer (ORA), tomografia do segmento anterior por coerência óptica para a avaliação paquimétrica corneal e das lamelas criadas e sistema de velocidade de onda (SVO), que mede a velocidade de propagação de ondas acústicas entre dois transdutores posicionados na superfície corneal antes e imediatamente, após a feitura da lamela. O primerio passo foi desenhado para o estudo das diferenças em relação à histerese corneal, fator de resistência corneal, mudanças na curvatura e velocidade de propagação de onda acústica entre córneas com lamelas finas e espessas. Posteriormente, as lamelas foram amputadas, e as medidas do sistema de velocidade de onda foram repetidas. Resultados: A média de espessura das lamelas ± desviopadrão (DP) foi de 108,5±6,9 (8,5% da espessura total) e 307,8±11,5 m (22,9% da espessura total), para os grupos de lamelas finas e espessas, respectivamente (p< 0,001). Histerese corneal e o fator de resistência corneal não apresentaram diferença estatística, após a criação de lamelas finas (p = 0,81 e p = 0,62, respectivamente). Histerese corneal foi significantemente mais baixa, depois da confecção de lamelas mais espessas (8,0±1,0 para 5,1±1,5 mmHg para medidas pré e pós-operatórias, respectivamente, p = 0,003, diminuição de 36,25%) e fator de resistência corneal também mostrou significante diminuição nesse grupo, após o procedimento cirúrgico; valores médios pré e pós-operatórios de 8,2±1,6 e 4,1±2,5 mmHg respectivamente (p= 0,007), diminuição de 50%. A ceratometria média simulada apresentou maiores valores, após a confecção das lamelas mais espessas em relação ao pré-operatório (ceratometria pré e pós-operatória de 39,5±1 D e 45,9±1,2 D, respectivamente, p= 0,003). Para o grupo de lamelas finas, não houve diferença estatisticamente significante (ceratometria pré e pós-operatória de 40,6±0,6 D e 41,4±1,0 D, respectivamente, p=0,55). Em relação ao Sistema de Velocidade de Onda, após a criação das lamelas e sua amputação, houve diminuição da velocidade de propagação acústica, embora na maior parte das posições não fosse estatisticamente significante. Conclusão: Nas condições experimentais estabelecidas por este estudo, a criação de lamelas de maior espessura pareceu exercer efeito mais relevante sobre a biomecânica da córnea de suínos / Purpose: To study the impact of programmed flaps at two different thicknesses on the biomechanical properties of the swine corneas. Methods: Twelve pig eyes were enrolled in this study and were formed two groups: 100m and 300 m flaps performed with the femtosecond laser. Each eye had the following procedure before the flap creation: raster photograph topographic maps, Ocular Response Analyzer (ORA), Optical Coherence Tomography to measure the pachymetry and flap thickness and Surface Wave Velocity system which is a prototype system that measures sonic wave propagation time between two transducers positioned on the corneal surface before and after flap creation. This first step was designed to investigate the differences in respect to corneal hysteresis, corneal resistance factor, curvature change and ultrasonic wave propagation between the groups with thinner and thicker flaps. After this initial procedure, flap amputation was performed and new measurements with the surface wave velocity system were taken again. Results: Measured flap thicknesses averaged 108.5±6.9 (8.5% of the total cornea) and 307.8±11.5 m (22.9% of the total cornea) for thin and thick flap groups, respectively (p< 0.001). Hysteresis and corneal resistance factor did not change significantly after flap creation in the thin flap group (p = 0.81 and p = 0.62, respectively). With thicker flaps, both parameters decreased significantly from 8.0±1.0 to 5.1±1.5 mmHg (p=0.003, reduction of 36.25%) and from 8.2±1.6 to 4.1±2.5 mmHg, respectively (p = 0.007), reduction of 50%. Simulated keratometry values increased in the thick flap group (from 39.5±1 D to 45.9±1.2 D, p=0.003) after flap creation and not in the thin flap group (from 40.6±0.6D to 41.4±1.0D, p= 0.55). Regarding surface wave velocity analysis, the surgical procedures induced lower values in some positions although most of them did not present statistically different results. Conclusion: In this experimental model, thicker flaps seemed to have a greater effect on the biomechanics of the swinish cornea
26

Laser-based hybrid process for machining hardened steels

Raghavan, Satyanarayanan 13 February 2012 (has links)
Cost-effective machining of hardened steel (>60 HRC) components such as a large wind turbine bearing poses a significant challenge. This thesis investigates a new laser tempering based hybrid turning approach to machine hardened AISI 52100 steel parts more efficiently and cost effectively. The approach consists of a two step process involving laser tempering of the hardened workpiece surface followed by conventional machining at higher material removal rates using lower cost ceramic tooling to efficiently cut the laser tempered material. The specific objectives of this work are to: (a) study the characteristics of laser tempering of hyper-eutectoid 52100 hardened steel, (b) model the laser tempering process to determine the resulting hardness, and (c) conduct machining experiments to evaluate the performance of the laser tempering based hybrid turning process in terms of forces, tools wear and surface finish. First, the microstructure alterations and phase content in the surface and subsurface layers are analyzed using metallography and x-ray diffraction (XRD) respectively. Laser tempering produces distinct regions consisting of - a tempered white layer and a dark layer- in the heat affected subsurface region of the workpiece. The depth of the tempered region is dependent on the laser scanning conditions. Larger overlap of laser scans and smaller scan speeds produce a thicker tempered region. Furthermore, the tempered region is composed of ferrite and martensite and weak traces of retained austenite (~ 1 %). Second, a laser tempering model consisting of a three dimensional analytical model to predict the temperature field generated by laser scanning of 52100 hardened steel and a phase change based hardness model to predict the hardness of the tempered region are developed. The thermal model is used to evaluate the temperature field induced in the subsurface region due to the thermal cycles produced by the laser scanning step. The computed temperature histories are then fed to the phase change model to predict the surface and subsurface hardness. The laser tempering model is used to select the laser scanning conditions that yield the desired hardness reduction at the maximum depth. This model is verified through laser scanning experiments wherein the hardness changes are compared with model predictions. The model is shown to yield predictions that are within 20 % of the measured hardness of the tempered region. Using the laser scanning parameters determined from the laser tempering model, cutting experiments using Cubic Boron Nitride (CBN) tools and low cost alumina ceramic tools are conducted to compare the performance of laser tempering based hybrid turning with the conventional hard turning process. The machining experiments demonstrate the possibility of higher material removal rates, lower cutting forces, improved tool wear behavior, and consequently improved tool life in the laser tempering based process. In addition, the laser tempered based hybrid turning process produce is shown to yield lower peak-to-valley surface roughness height than the conventional hard turning process. Furthermore, it is found that lower cost ceramic tools can be used in place of CBN tools without compromising the material removal rate.
27

Estudo comparativo entre a ceratectomia fotorrefrativa (PRK) e a ceratectomia subepitelial borboleta assistida a laser (LASEK borboleta) / Comparative study between photorefractive keratectomy (PRK) and butterfly laser-assisted subepithelial keratectomy (BLASEK)

Vinicius Coral Ghanem 29 August 2007 (has links)
OBJETIVO: Avaliar comparativamente os resultados de duas técnicas de cirurgia refrativa de superfície com excimer laser, ceratectomia fotorrefrativa (PRK) e ceratectomia subepitelial borboleta assistida à laser (LASEKb). LOCAL: Hospital de Olhos Sadalla Amin Ghanem, Joinville, Santa Catarina, Brasil. MÉTODOS: Realizou-se um estudo prospectivo, randomizado e duplo-cego envolvendo 102 olhos de 51 pacientes. Cada paciente teve aleatoriamente um dos olhos operado com a técnica do PRK e o outro com LASEKb. Os pacientes foram acompanhados por 1 ano. RESULTADOS: Não houveram diferenças significativas entre os dois grupos na acuidade visual (AV) para longe, sem correção, (P = 0,5593). No 12o mês pós-operatório (PO), 98,04% dos olhos no grupo do PRK e 96,08% no grupo do LASEKb atingiram AV sem correção de 20/20. A previsibilidade, eficácia, segurança e estabilidade não apresentaram diferença estatisticamente significativa entre os grupos. O índice de segurança foi de 1 no PRK e 0,996 no LASEKb. Um olho do grupo do LASEKb perdeu uma linha de visão. A porcentagem de olhos que apresentou EE aos 12 meses na faixa de ±0,50 D foi de 94,1% no grupo do PRK e de 86,3% no grupo do LASEKb (P = 0,1883). Enquanto que na faixa de ±1,0 D foi de 100% no grupo do PRK e 98% no grupo do LASEKb (P = 0,3125). Não houve necessidade de reoperações. O tempo médio de cirurgia na técnica PRK foi de 304,86 + 58,77 segundos (aproximadamente 5 minutos) e na técnica LASEKb de 608,35 + 76,88 segundos (aproximadamente 10 minutos) (P < 0,001). O tempo médio de reepitelização no grupo do PRK foi de 4,35 ± 0,48 dias (variação, 4 a 5 dias) e no grupo do BLASEK foi de 4,75 ± 0,72 dias (variação, 4 a 6 dias) (P < 0,002). Os níveis de dor e o desconforto ocular PO não foram estatisticamente diferentes entre os grupos, entretanto houve uma tendência para menor dor no PRK (3,31 ± 4,09 vs 4,43 ± 4,27; P = 0,18). Houve uma redução estatisticamente significativa nos valores do teste de Schirmer em todas as avaliação PO, tanto no PRK (23,6 ± 8,1 vs 19,4 ± 10,1; P < 0,002) quanto no LASEKb (22,4 ± 8,7 vs 18,9 ± 9,7; P = 0,01), entretanto não houve diferença entre os grupos. A opacificação corneana (OC) PO foi pequena nos dois grupos. Somente no 1o mês foi observado diferença estatística entre os grupos, com maior intensidade da OC no grupo do LASEKb (0,18 ± 0,3881) quando comparado ao PRK (0,08 ± 0,2109) (P = 0,039936). A maior intensidade foi observada no 3o mês, com redução gradativa até o 12o mês. CONCLUSÃO: Dentro das condições deste estudo, conclui-se que o PRK e o LASEKb mostraram resultados semelhantes, exceto que o PRK apresentou menor tempo cirúrgico, reepitelização corneana mais rápida e menor OC no 30o PO. / PURPOSE: Comparatively evaluate the results of two techniques of surface excimer laser refractive surgery, photorefractive keratectomy (PRK) and butterfly laser-assisted subepithelial keratectomy (BLASEK). SETTING: Sadalla Amin Ghanem Eye Hospital, Joinville, Santa Catarina, Brazil. METHODS: This is a prospective, randomized and double-masked study including 102 eyes from 51 patients. Each patient was randomized to have one eye operated on with PRK and the other with BLASEK. Patients were followed for 1 year. RESULTS: There were no significant differences between the groups regarding uncorrected distant visual acuity (VA) (p= 0.5593). On the 12th post-operative (PO) month, 98.04% of the eyes in the PRK group and 96.08% in the BLASEK group reached uncorrected VA of 20/20. The predictability, efficacy, safety and stability did not present statically significant difference between groups. The safety index was of 1 for PRK and 0.996 for BLASEK. One eye of the BLASEK group lost one line on the 12th PO month. The percentage of the eyes that presented spherical equivalent at 12 months in the range of ±0.50 D was 94.1% in the PRK group and 86.3% in the BLASEK group (p = 0.1883). While in the range of ±1.0 D it was 100% in the PRK group and 98% in the BLASEK group (p = 0.3125). There were no retreatments. The mean surgical time was 304.86 + 58.77 seconds (approximately 5 minutes) in PRK and 608.35 + 76.88 seconds in BLASEK (approximately 10 minutes) (P < 0,001). The mean reepithelization time in the PRK group was 4.35 ± 0.48 days (range, 4 to 5 days), and in the BLASEK group was 4.75 ± 0.72 days (range, 4 to 6 days) (P < 0.002). Pain scores and ocular discomfort were not statistically different between groups, although there was a trend towards a lower pain level with PRK (3.31 ± 4.09 vs. 4.43 ± 4.27; P = 0.18). Schirmer test values were significantly reduced from preoperative levels through 12 months with both PRK (23.6 ± 8.1 vs. 19.4 ± 10.1; P < 0.002) and BLASEK (22.4 ± 8.7 vs. 18.9 ± 9.7; P = 0.01), however there was no difference between groups in any time point. Haze incidence was slight in both groups. Only in the 1st PO month statistical difference between the groups was observed, with higher intensity in the BLASEK group (0.18 ± 0.3881) when compared to the PRK (0.08 ± 0.2109) (p = 0.039936). The highest intensity was observed on the 3rd month, with gradual reduction until the 12th month. CONCLUSION: In the conditions of this study, it can be concluded that PRK and BLASEK showed similar results, except that PRK presented shorter surgical time, faster corneal reepithelization and less haze at 30th PO days.

Page generated in 0.0714 seconds