• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 191
  • 120
  • 23
  • 12
  • 11
  • 6
  • 5
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 417
  • 196
  • 99
  • 92
  • 90
  • 87
  • 72
  • 71
  • 69
  • 63
  • 60
  • 53
  • 50
  • 45
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Avaliação da contaminação de um solo laterítico por lixiviado de aterro sanitário através de ensaios de laboratório e de retroanálise de campo. / Assessment of a lateritic soil contamination by sanitary landfill leachate using laboratory tests and in situ back analysis.

Zanon, Thiago Villas Bôas 21 October 2013 (has links)
Esta dissertação de mestrado tem como objetivo principal avaliar o transporte de poluentes de um lixiviado real de aterro sanitário em um solo laterítico do estado de São Paulo. A pesquisa objetiva também comparar dois métodos de avaliação de transporte de poluentes: ensaios laboratoriais e análise de dados de contaminação de campo. No aterro sanitário de Botucatu houve, comprovadamente, percolação do lixiviado pelo subsolo durante aproximadamente 15 anos, sob uma lagoa de acumulação de lixiviado sem revestimento de fundo. Foram coletadas amostras de solo subjacente à lagoa, uma areia argilosa, em três perfis verticais na superfície e nas profundidades de 0,25 m, 0,50 m, 1,00 m, 2,00 m e 4,00 m. Os poluentes investigados foram: arsênio, cádmio, carbono orgânico total (COT), chumbo, cloreto, cobre, cromo, ferro, manganês, níquel, nitrogênio Kjeldahl total (NKT) e zinco. Amostras indeformadas do solo local não contaminado foram também coletadas para ensaios de permeabilidade à água e ao lixiviado, assim como para ensaios de coluna. A condutividade hidráulica do solo é da ordem de 10-6 m/s, porém significativamente influenciada pelo gradiente hidráulico aplicado e pela duração da percolação. A condutividade hidráulica diminuiu com a percolação de lixiviado para ordens de grandeza entre 10-8 e 10-6 m/s, dependendo do gradiente hidráulico. Os ensaios de coluna mostraram concentrações efluentes dos elementos pesquisados superiores às afluentes, impossibilitando a obtenção de parâmetros de transporte de poluentes. A análise das amostras contaminadas coletadas in situ mostrou que, embora o solo local seja poroso e apresente alta permeabilidade, as concentrações dos elementos estudados eram inferiores aos limites legais de contaminação do órgão de controle ambiental estadual. O cloreto e o nitrogênio, para os quais não há limites legais, apresentaram-se no subsolo em concentrações elevadas, superiores às concentrações no solo natural e, em algumas amostras, às do lodo depositado no fundo da lagoa. / The aim of this research is to evaluate transport of pollutants from a sanitary landfill leachate through a Brazilian lateritic soil by two methods: laboratory tests and analysis of field contamination. In Botucatu Sanitary Landfill, leachate stored in an unlined pond infiltrated into the subsoil for 15 years. Samples of the subjacent soil, a porous clayey sand, were collected in three profiles located inside the area of the leachate pond at the following depths: surface, 0.25 m, 0.50 m, 1.00 m, 2.00 m and 4.00 m. The investigated pollutants were arsenic, cadmium, chloride, cooper, iron, lead, manganese, nickel, Kjeldahl nitrogen, total organic carbon (TOC) and zinc. The hydraulic conductivity measured in undisturbed and uncontaminated samples of the local soil, around 10-6 m/s, is significantly influenced by the applied hydraulic gradient and the percolation duration. When leachate substituted water as percolation fluid, the hydraulic conductivity decreased to values between 10-8 and 10-6 m/s depending on the hydraulic gradient. Chemical analysis of contaminated samples showed that concentrations of the researched elements in the subsoil were lower than legal maximum contamination limits established by the environmental agency of São Paulo state, in spite of the fact that the local soil is porous and has high hydraulic conductivity. On the other hand, chloride and Kjeldahl nitrogen, pollutants for which there are no legal limits, were found in concentrations much higher than background values, and in some samples even higher than those measured in the leachate sludge deposited in the bottom of the storage pond.
292

Influência da recirculação de percolado em sistemas de batelada de uma fase e híbrido na digestão da fração orgânica de resíduos sólidos urbanos / Influency of leachate recirculation in batch and one-phase reactors to anaerobic digestion of organic fraction of urban solid waste

Picanço, Aurélio Pessôa 23 April 2004 (has links)
Nesta tese foi estudada a influência da recirculação do percolado, ajustando as melhores taxas e freqüências, para degradação da fração orgânica dos resíduos sólidos urbanos, em sistema de batelada de uma e duas fases (híbrido). Foram utilizados reatores de 3,45 litros preenchidos com resíduo sólido urbano padrão (FORSUp), percolado como inóculo e um filtro anaeróbio como reator metanogênico. Foram testadas as taxas de recirculação do inóculo de 1%, 2,5%, 5%, 10%, 20%, 30% e 50% e seu monitoramento feito por análises físico-químicas e microbiológicas. O reator que apresentou melhores valores de produção de metano e redução de DQO foi aquele com taxa de recirculação de 20% do percolado metanogênico. Na segunda etapa foram operados três digestores de 50L, alimentados com a FORSUp com as melhores taxas de recirculação determinadas na primeira etapa desse trabalho e a obtida no trabalho de Salgado (2003). Um reator simulou o reator acidogênico de um sistema de duas fases, no qual 20% de seu inóculo foi injetado em um filtro anaeróbio (com tempo de detenção hidráulico de 24 horas). Um outro sistema com taxa de 10% de recirculação de percolado foi operado como reator de uma fase. Outro reator, inoculado com a mesma quantidade de FORSUp e percolado, porém, não se realizou qualquer recirculação do seu inóculo (controle), servindo para comparar os digestores de uma e duas fases. O sistema de duas fases, comparado aos demais reatores, confirmou que a taxa de recirculação de 20%, obteve maior eficiência na partida, com elevada produção de metano e maior percentual de degradação de sólidos. Os exames microscópicos realizados em amostras de percolado desses reatores revelaram predominância de organismos de morfologia com características de Methanococcus e Methanosarcina. Concluiu-se que a taxa de recirculação de percolado influi significativamente nos reatores degradando a matéria orgânica. O estudo cinético confirmou que o processo de digestão obedece a cinética das reações em série, com elevados valores de k´1 / This thesis studied the influence of the leachate recirculation, adjusting to the best rates and frequencies, for degradation of the organic fraction of the urban solid wastes, in one and two-phases (hybrid) system. Bioreactors of 3.45 L were used and filled out with OFMSW pattern, leachate as seed and an anaerobic filter as methanogenic reactor. The performance of the reactors was analyzed varying recirculation rates (1, 2.5, 5, 10, 20, 30 and 50 % in volume of seed). Leachate samples from these reactors were examined through microscopical examinations and physical-chemical analyses to evaluate its performance. The reactor with 20% recirculation rate, got larger efficiency in the departure, methane production and percentage of solid degradation, compared to the others reactors. In the second stage, three 50L digesters were operated and fed with standard OFMSW with the best recirculation rates of the first stage and the best rate obtained in Salgado (2003). A bioreactor simulated the acidogenic reactor of a two-phase system, in which 20% of its seed was injected in anaerobic filter (with hydraulic detention time of 24 hours). Another system, with 10% of recirculation rate of leachate was operated in a one-phase reactor. Once more bioreactor, inoculated like others, however, without any recirculation were studied to compare with one and two-phase reactor. The two-phase system confirmed that the 20% recirculation rate, compared to the others reactors, obtained better efficiency with high methane production and solid degradation. The microscopical examinations in the leachate samples from this reactor presented predominance of organisms with characteristical morphology from Methanococcus and Methanosarcina. It was concluded that the leachate recirculation has significant influence in the degradation of organic matter bioreactors. The kinetic study confirmed that the anaerobic process for OFMSW proceed the in series kinetics, with high constants values of first order
293

Estudo da fotocatálise heterogênea utilizando luz solar e ZnO como pré-tratamento de percolado de aterro sanitário / Study of application of ZnO using solar photoirradiation as pre-treatment of landfill leachate

Souza, Bruno Leandro Cortez de 31 October 2014 (has links)
O grande impacto ambiental causado pelo chorume proveniente de aterros sanitários impulsiona as pesquisas para o seu tratamento, com o objetivo de se obter a máxima degradação possível dos seus contaminantes recalcitrantes e tóxicos, diminuindo-se assim a sua toxicidade. O desenvolvimento de uma tecnologia eficiente e econômica para o tratamento é indispensável devido ao grande volume gerado e à legislação ambiental cada vez mais restritiva. Desta forma, os Processos Oxidativos Avançados (POAs) são avaliados como uma estratégia para o pré-tratamento, com um alto poder de degradação não seletivo e relação custo-benefício vantajosa. Dos diversos tipos de POAs existentes, aqueles que utilizam semicondutores para a fotocatálise heterogênea e luz solar como fonte de irradiação são os de maior interesse, devido a sua relativa eficiência, estabilidade fotoquímica, natureza não tóxica e baixo custo. Este estudo consistiu em avaliar o nível de degradação do chorume proveniente do aterro sanitário de Cachoeira Paulista - SP, utilizando como catalisador o ZnO irradiado pela luz solar, que possui um vasto espectro de fotoativação aliado ao seu baixo custo. As variáveis de entrada em dois níveis, foram o pH, o tempo de reação, a espessura da camada de ZnO impregnada sobre uma placa metálica e a concentração do efluente. Como variável resposta os valores de concentração expressa em Carbono Orgânico Total (COT) foi a mais adequada. O planejamento de experimentos utilizado foi o fatorial 23 com duplicata no ponto central. Na etapa delineatória, reduções de 28 % de COT foram alcançadas. A utilização da fotocatálise heterogênea utilizando ZnO fotoirradiado com luz solar se mostrou promissora para ser utilizada como um pré-tratamento do chorume. / The major environmental impact of leachate from landfills drives research to treat it, and aims to obtain the maximum degradation of their recalcitrant and toxic contaminants. The development of an efficient and economical treatment technology is indispensable due to the large volume generated and the increasingly restrictive environmental legislation. Thus, Advanced Oxidation Processes (AOPs) are evaluated as a strategy to pre-treatment with a high power non-selective degradation and advantageous cost-benefit ratio. From various types of POAs, those which use the heterogeneous photocatalytic semiconductor and solar light as the source of irradiation are the most interesting, because of its relative efficiency, photochemical stability, low cost and non-toxic nature. This study have assessed the level of degradation of the leachate from the landfill of Cachoeira Paulista - SP, using ZnO irradiated by sunlight as catalyst, which has a wide spectrum of photoactivation combined with its low cost. The input variables on two levels, were pH, reaction time, the thickness of the ZnO layer impregnated on a metal plate and concentration of the effluent. The most appropriate output variable was concentration, expressed in means of Total Organic Carbon (TOC). For the photocatalytic process, a factorial design (23) was used for the design of experiments. In final stage, reductions of 28% TOC were achieved. The use of heterogeneous photocatalysis using solar photoirradiated ZnO seems to be a great alternative as a pre-treatment of leachate.
294

Recuperação da amônia liberada no processo de \"air stripping\" aplicado ao tratamento do lixiviado de aterros sanitários / Recovery of ammonia released from air stripping process applied to sanitary landfill leachate treatment

Ferraz, Fernanda de Matos 26 March 2010 (has links)
O lixiviado de aterros sanitários é um efluente líquido poluente devido, principalmente, à sua elevada concentração de amônia. Seu tratamento faz-se necessário para que sejam atendidas as exigências das legislações ambiental e trabalhista, além de minimizados os impactos ambientais de seu lançamento nos corpos d\'água. Esta pesquisa propõe a remoção da amônia presente no lixiviado por meio do processo físico-químico \"air stripping\", que promove a transferência da amônia da fase líquida para gasosa. Para que não se contribua com a poluição atmosférica, o efluente gasoso do \"air stripping\" deve ser tratado em solução de ácido sulfúrico ou água. A neutralização da amônia com solução de ácido sulfúrico gera o sulfato de amônio, e com água, a aquamônia. Tais subprodutos podem ser usados como fertilizantes. Nesta pesquisa, para remoção da amônia do lixiviado foi utilizada uma torre de PVC, com 2,24 m de altura e 15 cm de diâmetro, recheada com anéis do tipo Rashing de polietileno corrugados, com diâmetro de 1,5 cm e 5 cm de comprimento. As vazões de ar utilizadas foram 1200, 1600 e 3600 L/h e as vazões de lixiviado foram 18 e 30 L/h. Para ajuste no pH do lixiviado, utilizou-se hidróxido de cálcio (padrão analítico) e cal comercial. Os fluxos de líquido e ar eram em contracorrente. Para o recolhimento da amônia foram usados dois frascos de 6 L, preenchidos com 4 L de solução de ácido sulfúrico 0,4 mol/L ou água. Os resultados obtidos indicaram remoção praticamente completa de toda a amônia contida no lixiviado. Nas diferentes condições operacionais avaliadas, a concentração de amônia remanescente no lixiviado foi igual ou inferior aos 20 mg/L determinados pela Resolução 397/08 do CONAMA. Quanto ao recolhimento da amônia, a eficiência média obtida nos frascos lavadores próxima a 80%, tanto ) quando utilizada a solução de ácido sulfúrico 0,4 mol/L quanto quando utilizada água. / Sanitary landfill leachate is a pollutant liquid effluent mainly due to its high ammonia concentration. Its treatment is necessary due to environmental and labour legislation requirements, besides prevention of environmental impacts of leachate release in water bodies. This research proposes ammonia removal from leachate by air stripping process, which transfers ammonia from liquid to gaseous phase. In order to prevent atmospheric pollution, air stripping gaseous effluent must be treated with sulphuric acid solution or water. Ammonia neutralization by sulfuric generates ammonium sulfate and by water, aquammonia is generated. Such by-products may be used as fertilizer. In this research, in order to remove leachate ammonia it was used a PVC tower of 2.24 m high and 15 cm diameter, packed with Rashing rings of corrugated polyethylene of 1.5 cm diameter and 5 cm length. Air flows were 1200, 1600 and 3600 L/h and leachete flows were 18 e 30 L/h. Calcium carbonate (standard grade) and commercial hydrated lime were used for pH adjustments. Air and liquid flows were countercurrent. In order to recover ammonia, two flasks of 6 L were used and filled with 4 L of 0.4 mol/L sulfuric acid solution or water. Results showed that ammonia was almost completely removed from leachate. In all operational conditions evaluated, remaining ammonia concentration in leachate was equal or less than 20 mg/L, value established by Resolution 397/08 of Brazilian Council of the Environment. Ammonia recovery with water or a 0.4 mol/L sulfuric acid solution was about 80%.
295

Estratégias de tratamento de lixiviado de aterro sanitário com foco na matéria orgânica biodegradável e nitrogênio amoniacal / Strategies of landfill leachate treatment focused on biodegradable organic matter and ammonia nitrogen

Cano, Vitor 03 September 2014 (has links)
Introdução sistemas de tratamento de esgotos, quando aplicados ao tratamento de lixiviado de aterro sanitário, não têm apresentado bons resultados. Por conta disso, faz-se necessário o desenvolvimento de alternativas para o tratamento de lixiviado. Objetivo avaliar o pós-tratamento de lixiviado de aterro sanitário por wetland construído de fluxo subsuperficial horizontal e reator biológico de leito móvel (RBLM). Materiais e métodos foram realizados dois experimentos com tratamento de lixiviado após remoção de amônia por dessorção. No experimento 1 utilizou-se wetlands construídos de fluxo horizontal em escala de bancada (volume total de 30,8 L), plantados com Cyperus papyrus, Heliconia psittacorum e Gynerium sagittatum, e um controle sem vegetação, preenchidos com pedrisco calcário. O sistema foi alimentado com lixiviado diluído em água em diferentes proporções (entre 10 por cento e 30 por cento ) com concentração média de DQO entre 336 e 750 mg.L-1 e nitrogênio amoniacal (N-NH4) entre 47 e 199 mg.L-1. A operação ocorreu em três etapas: (1ª) alimentação contínua e TDH médio entre 2,7 e 5,3 d; (2ª) regime de ciclos de recirculação do efluente, para avaliar o efeito do aumento de TDH para 21 dias; (3ª) alimentação contínua de duas unidades wetlands em série, visando elevar o TDH (entre 8,1 e 9,9 d) sem recirculação. O experimento 2 foi implantado em escala piloto, com uma unidade de dessorção de amônia seguida de um Reator Biológico de Leito Móvel (RBLM) e um biofiltro anóxico. O RBLM (volume efetivo de 380 L) foi preenchido em 50 por cento com anel pall. Resultados e discussão No experimento 1, obteve-se baixa remoção de DQO com médias inferiores a 40 por cento e concentração final entre 270 e 750 mg.L-1. No entanto, verificou-se remoção de N-NH4, principalmente na 2ª e 3ª etapas, com médias de remoção entre 43 por cento e 81 por cento , resultando em concentração de 20 a 223 mg.L-1, com influência do TDH. No experimento 2, problemas técnicos durante a instalação e operação inicial e interdição do campus da USP-Leste prejudicaram a adaptação do reator e impediram o seu monitoramento por tempo suficiente para geração de dados consistentes, sendo interrompido na fase inicial. Conclusões A baixa eficiência para DQO provavelmente está relacionada à recalcitrância do lixiviado, ou devido à inibição dos microrganismos por toxicidade. Quanto ao N-NH4, infere-se que o aumento do TDH proporcionou maior tempo de difusão de oxigênio para o sistema wetland, suprindo a demanda das bactérias heterotróficas, o que possibilitou utilização do oxigênio excedente pelas nitrificantes, culminando na oxidação do N-NH4. / Introduction sewage treatment systems, when applied to the treatment of landfill leachate, have not shown good results. Thus it is necessary to develop alternatives for the treatment of leachate. Objective To assess the post-treatment of landfill leachate by horizontal subsurface flow constructed wetland and moving bed biofilm reactor (MBBR). Materials and methods Two experiments were conducted with treatment of the leachate after removal of ammonia by stripping. In experiment 1, horizontal flow constructed wetlands, at bench scale (total volume of 30.8 L), planted with Cyperus papyrus, Heliconia psittacorum and Gynerium sagittatum, and a control without vegetation, were filled with calcareous gravel. The system was fed with leachate diluted in water with different proportions (between 10 per cent and 30 per cent ) with mean COD concentration of between 336 and 750 mg.L-1 and ammonia nitrogen (NH4-N) between 47 and 199 mg L-1. The operation was divided in three stages: (1st) continuous feeding with mean HRT between 2.7 and 5.3 d; (2nd) regime of effluent recirculation to evaluate the effect of increasing the HRT to 21 days; (3rd) continuous feeding with two wetlands units in series, aimed HRT increasing (between 8.1 and 9.9 d) without recirculation. Experiment 2 was implemented on a pilot scale, with a unit of ammonia stripping followed by MBBR and an anoxic biofilter. The MBBR (380 L working volume) was filled 50 per cent with pall ring. Results and discussion In experiment 1, the COD removal was low, with averages below 40 per cent , with effluent concentration between 270 and 750 mg.L-1. However, there was removal of NH4-N, especially in the 2nd and 3rd stages, with average removal between 43 per cent and 81 per cent , resulting in concentration between 20 and 223 mg.L-1, with HRT influence. In experiment 2, technical problems during the installation and initial operation and interdiction of the campus of USP-Leste disrupted the reactor acclimation and precluded the monitoring for sufficient time to generate consistent data for discussion. Conclusions The low efficiency for COD is probably related to the recalcitrance of the leachate, or due to inhibition of microorganisms by toxicity. For NH4-N, it is inferred that the increase of the HRT provided greater time for diffusion of oxygen to the wetland system, meeting the demand of heterotrophic bacteria, which allowed the use of excess oxygen by nitrifiers, culminating in the oxidation of NH4-N.
296

Safe Discharge of Landfill Leachate to the Environment

Unknown Date (has links)
The objective of this research was to determine if mature landfill leachate could be treated to a level so that it was safe to discharge to the environment. The treatment method was an Advanced Oxidation Process. The process utilized Titanium Dioxide and UV. Three different reactor types were used, falling film, flow through and falling film + Electron Magnetic Oxygen Hydrogen (EMOH). To improve removal pre-treatment with titanium dioxide settling were conducted in conjunction with treatment in a reactor. The best removal was obtained with pre-treatment with titanium dioxide settling, followed by the falling film + EMOH reactor. In 8 hours, removal was 63% for COD, 53% for ammonia, 73% for alkalinity and 98% for calcium hardness. The kinetics found in this experiment show that full treatment times for safe discharge vary between contaminates. For complete removal of all tested contaminates to safe discharge regulations requires 185 hour of treatment. / Includes bibliography. / Thesis (M.S.)--Florida Atlantic University, 2015. / FAU Electronic Theses and Dissertations Collection
297

Avaliação da co-disposição do lodo de tanques sépticos e fração orgânica de resíduos sólidos domiciliares em reatores anaeróbios / Evaluation of co-disposal of sludge from septic tanks and organic fraction of domestic solid waste in anaerobic reactors

Vitor Tosetto 31 August 2009 (has links)
Apesar de surgir como um país emergente, infelizmente a situação do saneamento básico no Brasil é bastante precária. Dos 5.507 municípios brasileiros apenas 52,2% possuem algum tipo de serviço de esgotamento sanitário (IBGE, 2000). Diante deste cenário alarmante, soluções individuais passam a ganhar mais importância. A adoção de tanques sépticos como uma alternativa para a solução do esgoto sanitário, em regiões carentes de rede de esgoto, passa a ser viável devido ao seu baixo custo e eficiência satisfatória. No entanto, a operação inadequada dessas pequenas unidades podem se tornar um passivo ambiental, em virtude do lodo produzido, subproduto da degradação anaeróbia. A solução mais fácil e prática seria a sua disposição em Estações de Tratamento de Efluente, no entanto é uma minoria dos municípios brasileiros, 20,2% (IBGE, 2000), que contam com estas unidades. A proposta do presente trabalho foi simular a comportamento da disposição do Lodo de Tanques Sépticos (LTS) em aterros sanitários, juntamente com resíduos sólidos domiciliares (RSD). Por meio de quatro reatores anaeróbios, com 50 litros cada, avaliaram-se os efeitos da degradação anaeróbia da Fração Orgânica do RSD (FORSD) na presença de LTS. Todos os reatores possuíam a mesma quantidade de FORSD, 28 kg. Cada unidade experimental recebeu quantidades diferentes de LTS: reator 1 = 0 L; reator 2 = 4,9 L; reator 3 = 9,8 L e reator 4 = 14,7 L. O monitoramento acompanhou as características químicas e a quantidade do lixiviado, a composição do biogás e as mudanças físico-químicas na mistura de FORSD e LTS no início e no final do experimento. Entre os resultados obtidos, destaca-se a eficiência de remoção de DQO da FORSD, 21%, 51%, 68% e 73% para os reatores 1, 2, 3 e 4 respectivamente. E a aceleração na degradação anaeróbia nos reatores que receberam LTS, devido a produção precoce de metano, aparecimento no 40º dia nos reatores tratados com LTS e pela disponibilidade imediata de nutrientes, observada pelas análises de nitrogênio amoniacal. / Despite being an emerging country, unfortunately the sanitary situation of Brazil is quite precarious. Only 52.2% of the 5,507 brazilian municipalities have some type of sanitary service (IBGE, 2000). In this alarming scenario, individual solutions are gaining more importance. The adoption of septic tanks as an alternative to the solution of the sewage becomes viable due to its low cost and satisfactory performance. However, the inappropriate operation of these small units can become an environmental problem because of the produced sludge, sub product of anaerobic degradation. This material must be managed adequately and securely to prevent possible contamination of soil and water. The easiest and practice solution would be its disposal in sewage treatment stations, however there are only 20.2% (IBGE, 2000) of all the brazilian cities which rely on these units. The purpose of this study was to evaluate the performance of the disposal of sludge from septic tanks (LTS) in landfills, along with domestic solid waste (RSD). Using four anaerobic reactors, with 50 liters each, the effects of anaerobic degradation of organic fraction of the RSD (FORSD) in the presence of LTS were evaluated. All reactors had the same amount of FORSD, 28 kg. Each experimental unit received different amounts of LTS: Reactor 1 = 0 L; Reactor 2 = 4.9 L, Reactor 3 = 9.8 L and Reactor 4 = 14.7 L. The monitoring followed the characteristics and quantity of leachate, the composition of biogas and changes in physical-chemical mixture of FORSD and LTS at the beginning and the end of the experiment. The results highlight the efficiency of removal of the DQO of FORSD, 21%, 51%, 68% and 73% for reactors 1, 2, 3 and 4, respectively, and the acceleration in the degradation in anaerobic reactors that received LTS, due to early production of methane, appearing in 40º day in reactors treated with LTS and the ready availability of nutrients, observed by the analysis of ammonia nitrogen.
298

Estudo de tratabilidade de lixiviado de aterro sanitário submetido à eletro-oxidação como pré-tratamento a um sistema de lodos ativados operado em batelada / Study treatability of landfill leachate subjected to electro-oxidation as a pretreatment to an activated sludge batch system

Natália de Souza Pelinson 08 November 2013 (has links)
O lixiviado de aterro sanitário é um efluente gerado a partir da mistura de líquidos produzidos na degradação de resíduos sólidos e a água pluvial que infiltra o depósito de material. Estudos na literatura, abordando tratamento de lixiviados de aterro sanitário, indicam que os processos biológicos podem não ser suficientes para que os padrões de lançamento vigentes na legislação sejam cumpridos. Neste contexto os processos oxidativos avançados estão sendo apontados como uma alternativa atrativa para efluentes que apresentam baixa biodegradabilidade. A presente pesquisa objetivou avaliar, em escala de bancada, a tratabilidade do lixiviado de aterro sanitário com aplicação do tratamento de oxidação eletroquímica seguida pelo tratamento biológico de um sistema de lodos ativados operado em batelada. A eletro-oxidação promove a remoção ou degradação de espécies poluentes, direta ou indiretamente, por meio de processos que não necessitam de adição de grandes quantidades de produtos químicos. Nos ensaios realizados com lixiviado bruto e com lixiviado alcalinizado submetido ao tratamento físico-químico de air stripping não houve necessidade de adicionar eletrólitos suporte para a oxidação química ocorrer e ao longo de tais ensaios a matéria foi mensurada quanto à DQO, COT e COD. Quando aplicada a eletro-oxidação no lixiviado bruto (sem tratamento prévio), houve 87% de remoção de DQO utilizando o anodo DDB com aplicação de 48 A h L-1 (densidade de corrente de 100 mA cm-2) e 65% de remoção da DQO quando utilizado o anodo DSA, nas mesmas condições. Analogamente, foram obtidos valores percentuais de remoção de COT de 70 e 60%, respectivamente e ainda 61 e 67% em relação ao COD. A fim de se complementar os estudos quanto à atuação da eletroquímica no tratamento do lixiviado de aterros sanitários, o efluente eletro-oxidado foi adicionado a um sistema de lodos ativados em duas proporções volumétricas distintas (2,5 e 5%) combinadas com esgoto sanitário (97,5 e 95%, respectivamente). Para controle e possível análise na eficiência, foram realizados ensaios com lixiviado bruto (5% de lixiviado bruto e 95% de esgoto sanitário) e somente esgoto sanitário (100%). Foram obtidos valores de remoção de DQO de: 75% em condição 100% esgoto sanitário, 64% com adição 2,5% de lixiviado eletro-oxidado, 57% com adição de 5% de lixiviado eletro-oxidado e 38% com adição de 5% de lixiviado bruto, além de valores percentuais de remoção de COT em cerca de 56, 52, 47 e 37%, respectivamente. E ainda foram obtida remoções nos valores de DBO na ordem de 91, 87, 64 e 24%, respectivamente. De forma geral, o sistema combinado proposto atingiu eficiências consideráveis e se mostrou compatível com o intuito de se estudar o aumento da tratabilidade por meio da aplicação de processos eletroquímicos em lixiviado bruto. / The landfill leachate is a wastewater generated from the mixture of liquids produced in the degradation of solid waste and rainwater that infiltrates the landfill. Studies in the literature approaching the treatment of landfill leachate indicate that biological processes may not be sufficient for the discharge standards prevailing in the present legislation. In this context the advanced oxidation processes (AOP) are being singled out as an attractive alternative for wastewater with a low biodegradability. This study aimed to evaluate, in a bench scale treatability of landfill leachate treatment with application of electrochemical oxidation followed by biological treatment of an activated sludge batch system. The electro-oxidation promotes the removal or degradation of pollutants species directly or indirectly, through processes which do not require addition of large amounts of chemicals. For tests with raw leachate and leachate with alkaline subjected to physico- chemical treatment of air stripping, there was no need to add support for electrolytes and chemical oxidation occurs over such trials the subject was measured as the COD, TOC and DOC. When applied the electro-oxidation in the raw leachate (without treatment) was reached 87% for COD removal using the DDB anode with the application of 48 L h-1 (current density 100 mA cm-2) and 65% COD removal when using the DSA anode under the same conditions. Similarly, the percentage values of TOC removal are 70 and 60 % respectively and also 61 and 67% compared to the DOC was obtained. In order to complement the studies regarding the performance of the electrochemical treatment of landfill leachate, the electro-oxidized effluent was added to an activated sludge system in two different volume ratios (2,5 and 5%) combined with sewage (97.5 and 95%, respectively). For control and possible efficiency analysis, testing with raw leachate (5% and 95 % crude leachate sanitary sewer) and only sanitary wastewater (100 %) were performed. Values of COD removal was obtained: 75% in 100% sewage condition, 64% with addition of 2,5% leachate electro- oxidized , with 57% addition of 5% leachate electro- oxidized and 38% with the addition of 5% raw leachate , and percentage values of TOC removal by about 56, 52, 47 and 37% , respectively. And BOD removal values were obtained in the order of 91, 87, 64 and 24%, respectively. In general, the proposed combined system has achieved considerable efficiency and proved to be compatible with the aim of studying the increased tractability through the use of electrochemical processes raw leachate.
299

Geração de lixiviados de aterros sanitários na Região Metropolitana de São Paulo: histórico e perspectivas / Generation of leachate from landfills in the metropolitan region of São Paulo: history and perspectives

Sulamita de Souza Silva Cavalcante 08 September 2014 (has links)
O tratamento e a disposição final de resíduos sólidos urbanos é um dos grandes problemas ambientais da atualidade. No caso dos aterros sanitários, as áreas para implantação desses empreendimentos são cada vez mais escassas, especialmente nos grandes centros urbanos, exatamente onde há grande geração de resíduos. É notória a necessidade de se buscar alternativas adequadas para a disposição final de resíduos sólidos urbanos. A correta disposição de resíduos em aterros sanitários exige que esses empreendimentos sejam tratados de forma integral, desde a escolha do local, o desenvolvimento do projeto e a execução da obra até o gerenciamento da operação e ações correlatas de monitoramento ambiental. O objetivo dessas ações é minimizar os potenciais impactos ao meio ambiente, dos quais o de maior gravidade é a contaminação do solo e das águas pelos lixiviados gerados nos aterros. Os lixiviados de aterros sanitários são produzidos durante toda sua vida útil e após seu encerramento, devendo ser coletados, tratados e monitorados por várias décadas. Atualmente, não se sabe de maneira precisa qual é o volume e por quanto tempo ocorre a geração de lixiviados na maioria dos aterros sanitários no Brasil. Para esse trabalho realizou-se o levantamento dos aterros sanitários em operação e encerrados no período de 1998 a 2012 na Região Metropolitana de São Paulo, bem como da geração de lixiviados durante o mesmo período. A partir dessas informações traçou-se a série histórica referente a esse período, a partir da qual se pode inferir a grandeza da problemática para os próximos anos. Também são abordadas as necessidades futuras do sistema de tratamento de lixiviados. / The treatment and final disposal of urban solid wastes is one of the great environmental problems of present. In the case of sanitary landfills, the areas for settlement of such projects are increasingly scarce, especially in great urban areas, exactly where there is great waste production. It is notable the necessity of searching adequate alternatives for the final disposal of solid wastes. The correct disposal of solid wastes in sanitary landfills requires that these projects be treated in an integral approach, since the choice of the site, the project development, and the execution of the construction, to the operation management and correlated environmental monitoring actions. The intent of such actions is to minimize potential risks to the environment, being one of the most serious the soil and water contamination by the leachate generated in landfills. Landfill leachate is produced during the operation and after closure of landfills. They must be collected, treated and monitored for several decades. Currently, in most of landfills in Brazil, there is no accurate information about the volume of generated leachate and for how long it is produced. For this dissertation it has been held a survey of operating and closed landfills from 1998 to 2012 in the metropolitan area of São Paulo, as well as the leachate generated. Using these data, a historical series of this period has been traced, from which one can infer the magnitude of the problem for the next years. This study also addresses future need of the leachate treatment system.
300

O lixiviado dos aterros sanitários em estações de tratamento dos sistemas públicos de esgotos / The leachate from landfill in wastewater treatment systems public sewers

Miriam Moreira Bocchiglieri 11 May 2010 (has links)
O presente trabalho discute o recebimento de lixiviado de aterros sanitários em estações de tratamento do sistema público de esgotos para tratamento conjunto. Descreve os processos de geração do lixiviado nos aterros e faz uma avaliação desse recebimento em quatro estações de tratamento em operação no Estado de São Paulo que empregam processos biológicos de tratamento por lodos ativados convencional e por batelada, lagoas de estabilização (anaeróbia seguida de facultativa) e lagoas aeradas. Também apresenta a variação da produção de lixiviado em aterros sanitários em função dos períodos de chuva e seca, estabelecidos pela precipitação observada no período avaliado. Conclui que o tratamento conjunto de lixiviado de aterro é uma alternativa a ser considerada no planejamento dos sistemas de resíduos sólidos e de esgotos sanitários. A adoção do tratamento conjunto traz benefícios a esses sistemas e à sociedade, pois pode representar economia de escala, atendimento às exigências legais e conformidade ambiental, promovendo melhores condições de saúde pública / This work discuss the receipt of sanitary landfill leachate by public wastewater treatment plants for joint treatment. It describes the processes theough which leachate is generated in landfills and assesses its receipt in four wastewater treatment plants in the state of São Paulo that employ biological processes such as conventional and batch activated sludge and stabilization ponds (anaerobic pond followed by facultative pond). Additionally, the work shows the variation in the production of leachate during the dry and rainy seasons, which were established based on the volume of rainfall during the period of study. The conclusion is that the joint treatment of landfill leachate by wastewater treatment plants with the appropriate technical and operational criteria is na alternative to be considered in the planning of solid waste and sanitary sewer systems and the society because it would result in economy of scale, compliance with legal and environmental legislation, and improvement of public health

Page generated in 0.0743 seconds