Spelling suggestions: "subject:"ligas dde cromo"" "subject:"ligas dee cromo""
21 |
Avaliação comparativa de propriedades geradas pelos processos de soldagem TIG e brasagem em uma liga odontológica à base de Ni-Cr / Comparative assessment of properties generated by the process of TIG welding and brazing in a Ni-Cr dental alloyCarlos Antonio Freire Sampaio 27 March 2009 (has links)
O objetivo deste trabalho foi comparar, por meio de teste de microdureza e técnicas de caracterização metalúrgica, que inclui a metalografia, microscopia óptica, microscopia eletrônica de varredura (MEV) e espectroscopia por dispersão de energia (energy dispersive spectroscopy EDS), propriedades mecânicas e metalúrgicas de juntas soldadas pelos métodos TIG e brasagem em uma liga odontológica à base de Ni-Cr (FIT-CAST SB). As regiões estudadas em cada amostra foram o metal de base (MB), a zona termicamente afetada (ZTA) e a zona de fusão (ZF). Foram confeccionados 40 corpos-de-prova cilíndricos, em forma de bastão, com 2,5mm de diâmetro e 18,0mm de comprimento, obtidos apartir de fundição odontológica por centrifugação (técnica da cera perdida). Foram separados vinte cilindros para cada técnica, que após a soldagem formaram grupos de dez amostras para cada procedimento. A microestrutura do MB apresentou-se como uma matriz de uma solução sólida à base de Ni-Cr contendo um típico arranjo dendrítico de estrutura eutética. A liga apresentou precipitados metálicos na região interdendrítica da estrutura eutética. A análise química semi-quantitativa obtida através da técnica de EDS apresentou resultados compatíveis com a composição química quantitativa fornecida pelo fabricante da liga. Na brasagem, o MB e a ZF apresentaram microestruturas distintas. A ZF apresentou uma morfologia dendrítica grosseira com a presença de precipitados e porosidades. A análise química semiquantitativa por EDS da ZF mostrou-se bastante semelhante aos resultados obtidos para o MB. Nos corpos de prova unidos pelo processo de brasagem, a média de microdureza Vickers para o MB, a ZTA e a ZF foram respectivamente 83,501, 87,782 e 127,520. A análise estatística t-Student revelou diferenças significativas entre as regiões MB e ZF. No processo TIG, a microestrutura da ZF apresentou aspecto semelhante a do MB, porém, com o arranjo dendrítico mais refinado. A análise química semiquantitativa por EDS da ZF apresentou resultados semelhantes aos obtidos para o MB. Os corpos de prova apresentaram média de microdureza Vickers para o MB, a ZTA e a ZF respectivamente de: 74,607, 71,649 e 75,409. A análise estatística t-Student não revelou diferenças significativas entre as regiões analisadas. De acordo com a metodologia aplicada neste estudo e apartir da análise estatística dos dados obtidos, pode-se concluir que: o processo de união por brasagem gerou diferenças microestruturais e de microdureza Vickers entre a ZF e o MB; nas juntas soldadas pelo método TIG, os ensaios de microdureza Vickers revelaram uniformidade no comportamento mecânico entre a ZF, a ZTA e o MB; o processo de soldagem TIG gerou uma microestrutura bem semelhante entre a ZF e o MB e acarretou naquela apenas um arranjo dendrítico de estrutura eutética mais refinado; a análise química por EDS revelou que não houve variação de composição química significativa entre o MB e a ZF das juntas soldadas por ambos os métodos. / The purpose of this study was to compare, by means of microhardness testing and metallurgical characterization techniques as metallography, optical microscopy, scanning electron microscopy (SEM) and energy dispersion spectroscopy (EDS), mechanical and metallurgical properties of welded joints by TIG and brazing methods in a dental alloy based on Ni-Cr (FIT-CAST SB). The studied regions in each sample were the base metal (MB), the heat affected zone (ZTA) and the fusion zone (ZF). Forty cylindrical bodies-of-proof, stick-shaped, with 2.5mm diameter and 18.0mm in length were made from dental casting by centrifugation (lost wax technique). Twenty cylinders were used for each technique, which formed, after the welding, groups of ten samples for each procedure. The microstructure of the MB is presented as a matrix of a solid solution based on Ni-Cr with a typical dendritic arrangement of eutectic structure. The alloy presented metallic precipitates in the interdendritic region of the eutectic structure. The semiquantitative chemical analysis obtained by EDS technique showed results consistent with the quantitative chemical composition provided by the alloy manufacturer. In the brazing method, the MB and ZF showed different microstructures. The ZF showed a rough dendritic morphology with the presence of precipitates and porosities. The semiquantitative chemical analysis by EDS of the ZF had very similar results to those obtained for the MB. In the bodies-of-proof joined by the brazing process, the average Vickers microhardness for the MB, ZTA and ZF were respectively 83.501, 87.782 and 127.520. The t-Student statistical analysis revealed significant differences between the MB and ZF regions. In the TIG process, the microstructure of ZF presented similar aspect to the MB, but with a more refined dendritic arrangement. The semiquantitative chemical analysis by EDS of ZF presented similar results to those obtained for the MB. The bodies-of-proof had an average Vickers microhardness of the MB, ZTA and ZF respectively: 74.607, 71.649 and 75.409. The t-Student statistical analysis revealed no significant differences between the studied regions. According to the methodology applied in this study and from the statistical analysis of the obtained data, we can conclude that the process of union by brazing created microstructural and Vickers microhardness differences between the ZF and MB; in welded joints by the TIG method, the Vickers microhardness tests showed uniformity in the mechanical behavior among the ZF, ZTA and MB; the TIG welding process generated a very similar microstructure between the ZF and MB and made on that just a dendritic arrangement of more refined eutectic structure; the EDS chemical analysis revealed that there was no significant change in the chemical composition between the MB and ZF of welded joints by both methods.
|
22 |
Análise histológica e histomorfométrica de carótidas após o implante de stent de cromocobalto sem e com revestimento de polímero : modelo experimental porcinoGrudtner, Marco Aurelio January 2009 (has links)
Introdução: Apesar dos avanços significativos no tratamento endovascular das doenças arteriais coronarianas e periféricas, a reestenose intra-stent continua sendo o principal limitante a médio prazo desses procedimentos. O mecanismo da reestenose intra-stent é principalmente a hiperplasia intimal, já que o stent impede a retração elástica aguda e resiste ao remodelamento geométrico negativo tardio. A hiperplasia intimal ocorre basicamente em resposta à formação de trombo local, à inflamação e às dissecções intimais e mediais secundárias à injúria causada pelo stent, sendo o grau de resposta intimal a base dos efeitos a longo prazo. O uso de stents com hastes menores e revestidos com drogas ou polímeros tem sido considerado uma nova alternativa para a prevenção da reestenose intra-stent. Objetivo: Analisar a resposta arterial ao implante de stent de cromo-cobalto sem e com revestimento de polímero Camouflage® em artérias carótidas de suínos, utilizando os seguintes parâmetros histológicos: grau de endotelização, conteúdo de células musculares lisas, grau de angiogênese, conteúdo de fibrina, grau de inflamação e injúria; além da análise histomorfométrica. Método: Stents balões-expansíveis de cromo-cobalto ( 8 stents CC Flex e 5 stents CC Flex Proactive) de 4 x 16 mm foram implantados em artérias carótidas comuns de oito suínos jovens, sendo um stent liberado em cada artéria. Após 30 dias, as artérias contendo os stents foram removidas, fixadas e coradas pelos métodos de hematoxilina/eosina e Verhoeff/Van Giesson. O segmento arterial contendo o stent foi dividido em 3 blocos distintos: proximal, médio e distal. Os cortes histológicos foram obtidos utilizando-se micrótomo de impacto (Polycut S, Leica, Alemanha) equipado com navalha de tungstênio de 16 cm, tipo D (Leica, Alemanha), com 5 ^m de espessura. A navalha de tungstênio mantém as hastes dos stents intactas nas secções transversas, minimizando os artefatos potenciais causados pela retirada dos stents. A avaliação foi realizada através de critérios histológicos e histomorfométricos. Resultados: Todos os stents foram implantados com sucesso e sem dificuldades técnicas. A análise histológica em 30 dias evidenciou alto grau de endotelização em todos os segmentos avaliados e leve à moderada infiltração de células musculares na íntima. Observou-se baixo grau de angiogênese em cerca de 50% dos segmentos avaliados e ausência completa de deposição de fibrina em pelo menos 80%, com distribuição semelhante entre os grupos. A resposta inflamatória e o grau de injúria causadas pelas hastes dos stents também foram discretas e similares entre os grupos e não houve correlação entre resposta inflamatória e injúria e desses parâmetros com a área de neoíntima. O grau de obstrução neo-intimal identificada neste período foi pequeno (15,1% +/- 8,38 CC Flex x 15,5%+/- 5,39 CC Flex ProActive) e estatisticamente não significativo entre os grupos (p=0,785). Conclusão: Os achados deste estudo experimental sugerem que o uso de stents de cromo-cobalto revestidos com polímero Camouflage® em artérias carótidas de suínos parece estar associado, pelo menos no curto prazo, a uma resposta histológica semelhante àquela encontrada após o implante de stents de cromo-cobalto não revestidos. Neste período não se observou uma menor hiperplasia intimal em virtude do revestimento de polímero. / Introduction: Despite all the advances in the endovascular treatment of coronary and peripheral artery diseases, in-stent restenosis is still the main limiting factor of these procedures in the medium and long-term. The mechanism of in-stent restenosis is mainly the intimal hyperplasia, as the stent prevents acute elastic recoil and later negative geometric arterial remodeling. Intimal hyperplasia occurs basically in response to the formation of local thrombus, inflammation and intimal and medial dissections secondary to the injury caused by the stent, with the degree of intimal response being the cause of long-term effects. Coating drug-eluting stents with polymers and drugs with thinner struts have been considered a new alternative for in-stent restenosis prevention. Objective: Analyse the arterial response to the cobalt-chromium stent implant with and without polymer coating Camouflage® in carotid arteries of pigs, using the following histological parameters: degree of endothelialization, smooth muscle cells (SMC) content, degree of angiogenesis, intimal fibrin content, degree of inflammation and injury; plus histomorphometric analysis. Method: Cobaltchromium balloon-expandable stents (8 CC Flex stents and 5 CC Flex Proactive), 4 x 16 mm, were deployed in common carotid arteries of 8 young pigs, with one stent being deployed in each artery. After 30 days, the arteries containing the stents were removed and underwent fixation and staining using the hematoxilin/eosin and Verhoeff /Van Giesson methods. The arterial segment containing the stent was divided into 3 distinct portions: proximal, middle and distal. The histological sections were obtained using impact microtome (Polycut S, Leica, Germany), equipped with a 16 cm, type D, 5 ^m thick tungsten knife (Leica, Germany). The tungsten knife maintains the stent shaft intact in cross sections, minimizing the potential artifacts caused by stent removal. The evaluation was carried out using histological and histomorfometric criteria. Results: All the stents were deployed with success and with no technical difficulties. The histological analysis performed after 30 days showed a high level of endothelialization in all the evaluated portions and mild to moderate infiltration of the SMC in the intima layer. A low level of angiogenesis of about 50% of the evaluated portions was observed and a complete absence of fibrin deposition in at least 80% of the portions, with similar distribution among the groups. The inflammatory response and the level of injury caused by the struts of the stents were also minimum and this was similar among the groups. There was no correlation between inflammatory response and injury and between the two latter parameters and the neo-intima area. The level of neo-intimal obstruction identified in this period was small (15,1% +/- 8,38 CC Flex x 15,5%+/- 5,39 CC Flex ProActive ) and no statistical significance between the groups (p=0,785). Conclusion: The findings of this experimental study suggest the use of balloonexpandable cobalt-chromium stents coated with polymer Camouflage® in carotid arteries of pigs seems to be associated, at least in the short-term, with a similar histological response to that found in the implantation of non-coated cobalt-chromium stents. In this period, a lower intimal hyperplasia was not observed with polymer coating stents.
|
23 |
Análise histológica e histomorfométrica de carótidas após o implante de stent de cromocobalto sem e com revestimento de polímero : modelo experimental porcinoGrudtner, Marco Aurelio January 2009 (has links)
Introdução: Apesar dos avanços significativos no tratamento endovascular das doenças arteriais coronarianas e periféricas, a reestenose intra-stent continua sendo o principal limitante a médio prazo desses procedimentos. O mecanismo da reestenose intra-stent é principalmente a hiperplasia intimal, já que o stent impede a retração elástica aguda e resiste ao remodelamento geométrico negativo tardio. A hiperplasia intimal ocorre basicamente em resposta à formação de trombo local, à inflamação e às dissecções intimais e mediais secundárias à injúria causada pelo stent, sendo o grau de resposta intimal a base dos efeitos a longo prazo. O uso de stents com hastes menores e revestidos com drogas ou polímeros tem sido considerado uma nova alternativa para a prevenção da reestenose intra-stent. Objetivo: Analisar a resposta arterial ao implante de stent de cromo-cobalto sem e com revestimento de polímero Camouflage® em artérias carótidas de suínos, utilizando os seguintes parâmetros histológicos: grau de endotelização, conteúdo de células musculares lisas, grau de angiogênese, conteúdo de fibrina, grau de inflamação e injúria; além da análise histomorfométrica. Método: Stents balões-expansíveis de cromo-cobalto ( 8 stents CC Flex e 5 stents CC Flex Proactive) de 4 x 16 mm foram implantados em artérias carótidas comuns de oito suínos jovens, sendo um stent liberado em cada artéria. Após 30 dias, as artérias contendo os stents foram removidas, fixadas e coradas pelos métodos de hematoxilina/eosina e Verhoeff/Van Giesson. O segmento arterial contendo o stent foi dividido em 3 blocos distintos: proximal, médio e distal. Os cortes histológicos foram obtidos utilizando-se micrótomo de impacto (Polycut S, Leica, Alemanha) equipado com navalha de tungstênio de 16 cm, tipo D (Leica, Alemanha), com 5 ^m de espessura. A navalha de tungstênio mantém as hastes dos stents intactas nas secções transversas, minimizando os artefatos potenciais causados pela retirada dos stents. A avaliação foi realizada através de critérios histológicos e histomorfométricos. Resultados: Todos os stents foram implantados com sucesso e sem dificuldades técnicas. A análise histológica em 30 dias evidenciou alto grau de endotelização em todos os segmentos avaliados e leve à moderada infiltração de células musculares na íntima. Observou-se baixo grau de angiogênese em cerca de 50% dos segmentos avaliados e ausência completa de deposição de fibrina em pelo menos 80%, com distribuição semelhante entre os grupos. A resposta inflamatória e o grau de injúria causadas pelas hastes dos stents também foram discretas e similares entre os grupos e não houve correlação entre resposta inflamatória e injúria e desses parâmetros com a área de neoíntima. O grau de obstrução neo-intimal identificada neste período foi pequeno (15,1% +/- 8,38 CC Flex x 15,5%+/- 5,39 CC Flex ProActive) e estatisticamente não significativo entre os grupos (p=0,785). Conclusão: Os achados deste estudo experimental sugerem que o uso de stents de cromo-cobalto revestidos com polímero Camouflage® em artérias carótidas de suínos parece estar associado, pelo menos no curto prazo, a uma resposta histológica semelhante àquela encontrada após o implante de stents de cromo-cobalto não revestidos. Neste período não se observou uma menor hiperplasia intimal em virtude do revestimento de polímero. / Introduction: Despite all the advances in the endovascular treatment of coronary and peripheral artery diseases, in-stent restenosis is still the main limiting factor of these procedures in the medium and long-term. The mechanism of in-stent restenosis is mainly the intimal hyperplasia, as the stent prevents acute elastic recoil and later negative geometric arterial remodeling. Intimal hyperplasia occurs basically in response to the formation of local thrombus, inflammation and intimal and medial dissections secondary to the injury caused by the stent, with the degree of intimal response being the cause of long-term effects. Coating drug-eluting stents with polymers and drugs with thinner struts have been considered a new alternative for in-stent restenosis prevention. Objective: Analyse the arterial response to the cobalt-chromium stent implant with and without polymer coating Camouflage® in carotid arteries of pigs, using the following histological parameters: degree of endothelialization, smooth muscle cells (SMC) content, degree of angiogenesis, intimal fibrin content, degree of inflammation and injury; plus histomorphometric analysis. Method: Cobaltchromium balloon-expandable stents (8 CC Flex stents and 5 CC Flex Proactive), 4 x 16 mm, were deployed in common carotid arteries of 8 young pigs, with one stent being deployed in each artery. After 30 days, the arteries containing the stents were removed and underwent fixation and staining using the hematoxilin/eosin and Verhoeff /Van Giesson methods. The arterial segment containing the stent was divided into 3 distinct portions: proximal, middle and distal. The histological sections were obtained using impact microtome (Polycut S, Leica, Germany), equipped with a 16 cm, type D, 5 ^m thick tungsten knife (Leica, Germany). The tungsten knife maintains the stent shaft intact in cross sections, minimizing the potential artifacts caused by stent removal. The evaluation was carried out using histological and histomorfometric criteria. Results: All the stents were deployed with success and with no technical difficulties. The histological analysis performed after 30 days showed a high level of endothelialization in all the evaluated portions and mild to moderate infiltration of the SMC in the intima layer. A low level of angiogenesis of about 50% of the evaluated portions was observed and a complete absence of fibrin deposition in at least 80% of the portions, with similar distribution among the groups. The inflammatory response and the level of injury caused by the struts of the stents were also minimum and this was similar among the groups. There was no correlation between inflammatory response and injury and between the two latter parameters and the neo-intima area. The level of neo-intimal obstruction identified in this period was small (15,1% +/- 8,38 CC Flex x 15,5%+/- 5,39 CC Flex ProActive ) and no statistical significance between the groups (p=0,785). Conclusion: The findings of this experimental study suggest the use of balloonexpandable cobalt-chromium stents coated with polymer Camouflage® in carotid arteries of pigs seems to be associated, at least in the short-term, with a similar histological response to that found in the implantation of non-coated cobalt-chromium stents. In this period, a lower intimal hyperplasia was not observed with polymer coating stents.
|
24 |
Fenomenologia crítica e correntes AC nos sistemas magnéticos reentrantes σ-Fe-C, σ-Fe-V e Au-FeBarco, Reginaldo January 2011 (has links)
Este trabalho consiste de um estudo da fenomenologia crítica nas vizinhanças da temperatura de Curie (TC) das ligas binárias reentrantes s-Fe1-xCrx, onde x = 0,46 e 0,49; s-Fe0,52V0,48 e Au1-yFey, onde y = 0,135; 0,15; 0,18 e 0,21. As técnicas experimentais empregadas neste estudo são (1) Magnetização e (2) Impedanciometria. As medidas efetuadas permitiram a obtenção dos parâmetros críticos da transição de fase para-ferromagnética e caracterizar a transição reentrante em baixas temperaturas. A criticalidade nas proximidades da temperatura de Curie foi estudada mediante o emprego de diversos métodos, que levaram à identificação dos expoentes críticos estáticos (magnetização), g (susceptibilidade paramagnética) e d (isoterma crítica). O comportamento crítico da susceptibilidade paramagnética nos sistemas s-FeCr e s-FeV é melhor descrito quando se considera o escalonamento estendido CHT (Campbell, Hukushima, Takayama), que supõe que a temperatura reduzida deve ser escrita como t = (T - Tc)/T. As componentes real e imaginária da permeabilidade magnética são obtidas a partir dos resultados de impedância em função da temperatura, da frequência e do campo magnético aplicado. Nas proximidades de TC, a parte real da permeabilidade se comporta como uma lei de potência, tanto acima como abaixo de TC. A análise deste comportamento crítico acima de TC leva a expoentes críticos razoavelmente coincidentes com aqueles obtidos a partir das medidas magnéticas. Dos resultados de magnetoimpedância, foi possível estimar o campo de anisotropia das amostras estudadas, confirmando a ocorrência das transições de fases para-ferromagnética e ferromagnética-vidro de spin. / In this work, we report an experimental study of the critical phenomenology near the Curie temperature (TC), of the reentrant binary alloys s-Fe1-xCrx, with x = 0.46 and 0.49; s-Fe0.52V0.48 and Au1-y-Fey, with y = 0.135; 0.15; 0.18 and 0.21. The employed techniques were (1) Magnetization and (2) Impedanciometry. From the results, the ferromagnetic critical phase transition and the reentrant transition at low temperatures were identified. The transition at the Curie temperature was studied using several methods and the static critical exponents (magnetization), g (susceptibility) and d (critical isotherm) were obtained. The description of the critical behavior of the paramagnetic susceptibility in the s-FeCr and s-FeV systems, was improved when the CHT (Campbell, Hukushima, Takayama) extended scaling was considered. In this scaling scheme, the reduced temperature is written as t = (T - Tc)/T. The complex magnetic permeability was obtained from the impedance measurements as a function of the temperature, frequency and magnetic field. Near TC, the real part of the permeability behaves as a power law of the conventional reduced temperature, either above and below TC. The values of critical exponents obtained from these analyses reproduce those obtained from the magnetic measurements. From the magnetoimpedance experiments it was also possible to estimate the anisotropy field. This property clearly reveals the sequential occurrence of the para-ferromagnetic and ferromagnetic-spin glass transitions upon decreasing the temperature.
|
25 |
Análise histológica e histomorfométrica de carótidas após o implante de stent de cromocobalto sem e com revestimento de polímero : modelo experimental porcinoGrudtner, Marco Aurelio January 2009 (has links)
Introdução: Apesar dos avanços significativos no tratamento endovascular das doenças arteriais coronarianas e periféricas, a reestenose intra-stent continua sendo o principal limitante a médio prazo desses procedimentos. O mecanismo da reestenose intra-stent é principalmente a hiperplasia intimal, já que o stent impede a retração elástica aguda e resiste ao remodelamento geométrico negativo tardio. A hiperplasia intimal ocorre basicamente em resposta à formação de trombo local, à inflamação e às dissecções intimais e mediais secundárias à injúria causada pelo stent, sendo o grau de resposta intimal a base dos efeitos a longo prazo. O uso de stents com hastes menores e revestidos com drogas ou polímeros tem sido considerado uma nova alternativa para a prevenção da reestenose intra-stent. Objetivo: Analisar a resposta arterial ao implante de stent de cromo-cobalto sem e com revestimento de polímero Camouflage® em artérias carótidas de suínos, utilizando os seguintes parâmetros histológicos: grau de endotelização, conteúdo de células musculares lisas, grau de angiogênese, conteúdo de fibrina, grau de inflamação e injúria; além da análise histomorfométrica. Método: Stents balões-expansíveis de cromo-cobalto ( 8 stents CC Flex e 5 stents CC Flex Proactive) de 4 x 16 mm foram implantados em artérias carótidas comuns de oito suínos jovens, sendo um stent liberado em cada artéria. Após 30 dias, as artérias contendo os stents foram removidas, fixadas e coradas pelos métodos de hematoxilina/eosina e Verhoeff/Van Giesson. O segmento arterial contendo o stent foi dividido em 3 blocos distintos: proximal, médio e distal. Os cortes histológicos foram obtidos utilizando-se micrótomo de impacto (Polycut S, Leica, Alemanha) equipado com navalha de tungstênio de 16 cm, tipo D (Leica, Alemanha), com 5 ^m de espessura. A navalha de tungstênio mantém as hastes dos stents intactas nas secções transversas, minimizando os artefatos potenciais causados pela retirada dos stents. A avaliação foi realizada através de critérios histológicos e histomorfométricos. Resultados: Todos os stents foram implantados com sucesso e sem dificuldades técnicas. A análise histológica em 30 dias evidenciou alto grau de endotelização em todos os segmentos avaliados e leve à moderada infiltração de células musculares na íntima. Observou-se baixo grau de angiogênese em cerca de 50% dos segmentos avaliados e ausência completa de deposição de fibrina em pelo menos 80%, com distribuição semelhante entre os grupos. A resposta inflamatória e o grau de injúria causadas pelas hastes dos stents também foram discretas e similares entre os grupos e não houve correlação entre resposta inflamatória e injúria e desses parâmetros com a área de neoíntima. O grau de obstrução neo-intimal identificada neste período foi pequeno (15,1% +/- 8,38 CC Flex x 15,5%+/- 5,39 CC Flex ProActive) e estatisticamente não significativo entre os grupos (p=0,785). Conclusão: Os achados deste estudo experimental sugerem que o uso de stents de cromo-cobalto revestidos com polímero Camouflage® em artérias carótidas de suínos parece estar associado, pelo menos no curto prazo, a uma resposta histológica semelhante àquela encontrada após o implante de stents de cromo-cobalto não revestidos. Neste período não se observou uma menor hiperplasia intimal em virtude do revestimento de polímero. / Introduction: Despite all the advances in the endovascular treatment of coronary and peripheral artery diseases, in-stent restenosis is still the main limiting factor of these procedures in the medium and long-term. The mechanism of in-stent restenosis is mainly the intimal hyperplasia, as the stent prevents acute elastic recoil and later negative geometric arterial remodeling. Intimal hyperplasia occurs basically in response to the formation of local thrombus, inflammation and intimal and medial dissections secondary to the injury caused by the stent, with the degree of intimal response being the cause of long-term effects. Coating drug-eluting stents with polymers and drugs with thinner struts have been considered a new alternative for in-stent restenosis prevention. Objective: Analyse the arterial response to the cobalt-chromium stent implant with and without polymer coating Camouflage® in carotid arteries of pigs, using the following histological parameters: degree of endothelialization, smooth muscle cells (SMC) content, degree of angiogenesis, intimal fibrin content, degree of inflammation and injury; plus histomorphometric analysis. Method: Cobaltchromium balloon-expandable stents (8 CC Flex stents and 5 CC Flex Proactive), 4 x 16 mm, were deployed in common carotid arteries of 8 young pigs, with one stent being deployed in each artery. After 30 days, the arteries containing the stents were removed and underwent fixation and staining using the hematoxilin/eosin and Verhoeff /Van Giesson methods. The arterial segment containing the stent was divided into 3 distinct portions: proximal, middle and distal. The histological sections were obtained using impact microtome (Polycut S, Leica, Germany), equipped with a 16 cm, type D, 5 ^m thick tungsten knife (Leica, Germany). The tungsten knife maintains the stent shaft intact in cross sections, minimizing the potential artifacts caused by stent removal. The evaluation was carried out using histological and histomorfometric criteria. Results: All the stents were deployed with success and with no technical difficulties. The histological analysis performed after 30 days showed a high level of endothelialization in all the evaluated portions and mild to moderate infiltration of the SMC in the intima layer. A low level of angiogenesis of about 50% of the evaluated portions was observed and a complete absence of fibrin deposition in at least 80% of the portions, with similar distribution among the groups. The inflammatory response and the level of injury caused by the struts of the stents were also minimum and this was similar among the groups. There was no correlation between inflammatory response and injury and between the two latter parameters and the neo-intima area. The level of neo-intimal obstruction identified in this period was small (15,1% +/- 8,38 CC Flex x 15,5%+/- 5,39 CC Flex ProActive ) and no statistical significance between the groups (p=0,785). Conclusion: The findings of this experimental study suggest the use of balloonexpandable cobalt-chromium stents coated with polymer Camouflage® in carotid arteries of pigs seems to be associated, at least in the short-term, with a similar histological response to that found in the implantation of non-coated cobalt-chromium stents. In this period, a lower intimal hyperplasia was not observed with polymer coating stents.
|
26 |
Fenomenologia crítica e correntes AC nos sistemas magnéticos reentrantes σ-Fe-C, σ-Fe-V e Au-FeBarco, Reginaldo January 2011 (has links)
Este trabalho consiste de um estudo da fenomenologia crítica nas vizinhanças da temperatura de Curie (TC) das ligas binárias reentrantes s-Fe1-xCrx, onde x = 0,46 e 0,49; s-Fe0,52V0,48 e Au1-yFey, onde y = 0,135; 0,15; 0,18 e 0,21. As técnicas experimentais empregadas neste estudo são (1) Magnetização e (2) Impedanciometria. As medidas efetuadas permitiram a obtenção dos parâmetros críticos da transição de fase para-ferromagnética e caracterizar a transição reentrante em baixas temperaturas. A criticalidade nas proximidades da temperatura de Curie foi estudada mediante o emprego de diversos métodos, que levaram à identificação dos expoentes críticos estáticos (magnetização), g (susceptibilidade paramagnética) e d (isoterma crítica). O comportamento crítico da susceptibilidade paramagnética nos sistemas s-FeCr e s-FeV é melhor descrito quando se considera o escalonamento estendido CHT (Campbell, Hukushima, Takayama), que supõe que a temperatura reduzida deve ser escrita como t = (T - Tc)/T. As componentes real e imaginária da permeabilidade magnética são obtidas a partir dos resultados de impedância em função da temperatura, da frequência e do campo magnético aplicado. Nas proximidades de TC, a parte real da permeabilidade se comporta como uma lei de potência, tanto acima como abaixo de TC. A análise deste comportamento crítico acima de TC leva a expoentes críticos razoavelmente coincidentes com aqueles obtidos a partir das medidas magnéticas. Dos resultados de magnetoimpedância, foi possível estimar o campo de anisotropia das amostras estudadas, confirmando a ocorrência das transições de fases para-ferromagnética e ferromagnética-vidro de spin. / In this work, we report an experimental study of the critical phenomenology near the Curie temperature (TC), of the reentrant binary alloys s-Fe1-xCrx, with x = 0.46 and 0.49; s-Fe0.52V0.48 and Au1-y-Fey, with y = 0.135; 0.15; 0.18 and 0.21. The employed techniques were (1) Magnetization and (2) Impedanciometry. From the results, the ferromagnetic critical phase transition and the reentrant transition at low temperatures were identified. The transition at the Curie temperature was studied using several methods and the static critical exponents (magnetization), g (susceptibility) and d (critical isotherm) were obtained. The description of the critical behavior of the paramagnetic susceptibility in the s-FeCr and s-FeV systems, was improved when the CHT (Campbell, Hukushima, Takayama) extended scaling was considered. In this scaling scheme, the reduced temperature is written as t = (T - Tc)/T. The complex magnetic permeability was obtained from the impedance measurements as a function of the temperature, frequency and magnetic field. Near TC, the real part of the permeability behaves as a power law of the conventional reduced temperature, either above and below TC. The values of critical exponents obtained from these analyses reproduce those obtained from the magnetic measurements. From the magnetoimpedance experiments it was also possible to estimate the anisotropy field. This property clearly reveals the sequential occurrence of the para-ferromagnetic and ferromagnetic-spin glass transitions upon decreasing the temperature.
|
27 |
Fenomenologia crítica e correntes AC nos sistemas magnéticos reentrantes σ-Fe-C, σ-Fe-V e Au-FeBarco, Reginaldo January 2011 (has links)
Este trabalho consiste de um estudo da fenomenologia crítica nas vizinhanças da temperatura de Curie (TC) das ligas binárias reentrantes s-Fe1-xCrx, onde x = 0,46 e 0,49; s-Fe0,52V0,48 e Au1-yFey, onde y = 0,135; 0,15; 0,18 e 0,21. As técnicas experimentais empregadas neste estudo são (1) Magnetização e (2) Impedanciometria. As medidas efetuadas permitiram a obtenção dos parâmetros críticos da transição de fase para-ferromagnética e caracterizar a transição reentrante em baixas temperaturas. A criticalidade nas proximidades da temperatura de Curie foi estudada mediante o emprego de diversos métodos, que levaram à identificação dos expoentes críticos estáticos (magnetização), g (susceptibilidade paramagnética) e d (isoterma crítica). O comportamento crítico da susceptibilidade paramagnética nos sistemas s-FeCr e s-FeV é melhor descrito quando se considera o escalonamento estendido CHT (Campbell, Hukushima, Takayama), que supõe que a temperatura reduzida deve ser escrita como t = (T - Tc)/T. As componentes real e imaginária da permeabilidade magnética são obtidas a partir dos resultados de impedância em função da temperatura, da frequência e do campo magnético aplicado. Nas proximidades de TC, a parte real da permeabilidade se comporta como uma lei de potência, tanto acima como abaixo de TC. A análise deste comportamento crítico acima de TC leva a expoentes críticos razoavelmente coincidentes com aqueles obtidos a partir das medidas magnéticas. Dos resultados de magnetoimpedância, foi possível estimar o campo de anisotropia das amostras estudadas, confirmando a ocorrência das transições de fases para-ferromagnética e ferromagnética-vidro de spin. / In this work, we report an experimental study of the critical phenomenology near the Curie temperature (TC), of the reentrant binary alloys s-Fe1-xCrx, with x = 0.46 and 0.49; s-Fe0.52V0.48 and Au1-y-Fey, with y = 0.135; 0.15; 0.18 and 0.21. The employed techniques were (1) Magnetization and (2) Impedanciometry. From the results, the ferromagnetic critical phase transition and the reentrant transition at low temperatures were identified. The transition at the Curie temperature was studied using several methods and the static critical exponents (magnetization), g (susceptibility) and d (critical isotherm) were obtained. The description of the critical behavior of the paramagnetic susceptibility in the s-FeCr and s-FeV systems, was improved when the CHT (Campbell, Hukushima, Takayama) extended scaling was considered. In this scaling scheme, the reduced temperature is written as t = (T - Tc)/T. The complex magnetic permeability was obtained from the impedance measurements as a function of the temperature, frequency and magnetic field. Near TC, the real part of the permeability behaves as a power law of the conventional reduced temperature, either above and below TC. The values of critical exponents obtained from these analyses reproduce those obtained from the magnetic measurements. From the magnetoimpedance experiments it was also possible to estimate the anisotropy field. This property clearly reveals the sequential occurrence of the para-ferromagnetic and ferromagnetic-spin glass transitions upon decreasing the temperature.
|
28 |
An?lise mec?nica e microestrutural das ligas de cobalto-cromo de uso odontol?gico ap?s sucessivas refundi??esDantas, H?rrisson de Almeida 30 May 2008 (has links)
Made available in DSpace on 2014-12-17T14:07:01Z (GMT). No. of bitstreams: 1
HarrisonAD.pdf: 3488100 bytes, checksum: 805801db06d21e5667735d16a5799fe2 (MD5)
Previous issue date: 2008-05-30 / The cobalt-chromium alloy is extensively used in the Odontology for the confection of metallic scaffolding in partial removable denture. During the last few years, it has been reported an increasing number of premature imperfections, with a few months of prosthesis use. The manufacture of these components is made in prosthetic laboratories and normally involves recasting, using parts of casting alloy
and parts of virgin alloy. Therefore, the objective of the present study was to analyze the mechanical properties of a commercial cobalt-chromium alloy of odontological
use after successive recasting, searching information to guide the dental prosthesis laboratories in the correct manipulation of the cobalt-chromium alloy in the process of casting and the possible limits of recasting in the mechanical properties of this material. Seven sample groups were confectioned, each one containing five test bodies, divided in the following way: G1: casting only with virgin alloy; G2: casting with 50% of the alloy of the G1 + 50% of virgin alloy; G3: casting with 50% of the alloy of the G2 + 50% of virgin alloy; G4: casting with 50% of the alloy of the G3 + 50% of virgin alloy; G5: 50% of alloy of the G4 + 50% of virgin alloy; G6: 50% of alloy
of the G5 + 50% of virgin alloy and finally the G7, only with recasting alloy. The modifications in the mechanical behavior of the alloy were evaluated. Moreover, it was carried the micro structural characterization of the material by optic and
electronic scanning microscopy, and X ray diffraction.and fluorescence looking into the correlatation of the mechanical alterations with structural modifications of the material caused by successive recasting process. Generally the results showed alterations in the fracture energy of the alloy after successive recasting, resulting mainly of the increasing presence of pores and large voids, characteristic of the
casting material. Thus, the interpretation of the results showed that the material did not reveal significant differences with respect to the tensile strength or elastic limit,
as a function of successive recasting. The elastic modulus increased from the third recasting cycle on, indicating that the material can be recast only twice. The fracture
energy of the material decreased, as the number of recasting cycles increased. With respect to the microhardness, the statistical analyses showedno significant differences. Electronic scanning microscopy revealed the presence of imperfections and defects, resulting of the recasting process. X ray diffraction and fluorescence did not show alterations in the composition of the alloy or the formation of crystalline
phases between the analyzed groups. The optical micrographs showed an increasing number of voids and porosity as the material was recast. Therefore, the general conclusion of this study is that the successive recasting of of Co-Cr alloys affects the mechanical properties of the material, consequently leading to the failure of the prosthetic work. Based on the results, the best recommendadition is that the use of the material should be limited to two recasting cycles / Ligas cobalto-cromo s?o extensivamente utilizadas na Odontologia para a confec??o de arma??es met?licas em pr?teses parciais remov?veis. Durante os ?ltimos anos, tem sido reportado um n?mero crescente de falhas prematuras, com poucos meses de utiliza??o das pr?teses. A fabrica??o desses componentes ? feita em laborat?rios prot?ticos e normalmente envolve a refundi??o, utilizando partes de
liga fundida e partes de liga virgem. Portanto, o objetivo do presente estudo foi analisar as propriedades mec?nicas de uma liga comercial de cobalto-cromo de uso odontol?gico ap?s sucessivas refundi??es, buscando informa??es no sentido de orientar os laborat?rios de pr?tese dent?ria na correta manipula??o dessa liga no processo de fundi??o e nos poss?veis limites de refundi??o desse material. Foram
confeccionados sete grupos de amostras, cada um contendo cinco corpos de prova, divididos da seguinte maneira: G1: fundi??o apenas com liga virgem; G2: fundi??o com 50% da liga do G1 + 50% de liga virgem; G3: fundi??o com 50% da liga do G2 + 50% de liga virgem; G4: fundi??o com 50% da liga do G3 + 50% de liga virgem; G5: 50% de liga do G4 + 50% de liga virgem; G6: 50% de liga do G5 + 50% de liga
virgem e finalmente o G7, s? com liga refundida. Foram avaliadas as principais modifica??es ocorridas no comportamento mec?nico dessa liga por meio de ensaios
de tra??o e microdureza. Al?m disso, foi realizada a caracteriza??o microestrutural do material por meio de microscopia ?ptica e eletr?nica de varredura, difra??o e
fluoresc?ncia de raios X procurando correlacionar as altera??es mec?nicas com modifica??es estruturais do material ocasionadas pelos sucessivos processos de
refundi??o. De forma geral os resultados mostraram altera??es na plasticidade e energia de fratura da liga ap?s sucessivas refundi??es, decorrentes principalmente
da crescente presen?a de poros e vazios, defeitos caracter?sticos da fundi??o do material. A interpreta??o dos resultados permitiu concluir que o material n?o apresentou diferen?as significativas em rela??o ? resist?ncia ? tra??o ou ao limite el?stico, em fun??o das sucessivas refundi??es. A energia de fratura do material mostrou tend?ncia ? diminui??o, ? medida que o material foi refundido. Em rela??o ?
microdureza, as an?lises estat?sticas mostraram n?o haver diferen?as significativas. A microscopia eletr?nica revelou a presen?a de falhas e defeitos, resultantes dos processos de refundi??es. A an?lise por fluoresc?ncia e difra??o de raios X n?o mostrou altera??es na composi??o da liga ou na forma??o de fases cristalinas entre os grupos analisados. As micrografias ?pticas mostraram um crescente n?mero de
vazios e aumento da porosidade ? medida que o material foi refundido. Assim, a conclus?o geral do trabalho ? que as sucessivas refundi??es em ligas de Co-Cr comprometem as propriedades mec?nicas do material, o que pode levar a falhas e consequentemente, ao fracasso do trabalho prot?tico. Com base nos resultados, o mais recomendado ? a utiliza??o de no m?ximo duas refundi??es, para que as propriedades do material n?o sejam comprometidas
|
Page generated in 0.0578 seconds