• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 77
  • 25
  • 18
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 144
  • 144
  • 66
  • 60
  • 39
  • 29
  • 27
  • 25
  • 23
  • 23
  • 22
  • 22
  • 21
  • 21
  • 20
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Modeling Pile Setup for Closed-Ended Pipe Piles Driven in Cohesive Soils

Alzahrani, Saeed 15 May 2023 (has links)
No description available.
12

Spiral Welded Pipe Piles For Structures In Southeastern Louisiana

Richard, Leeland 17 December 2010 (has links)
In an effort to obtain 100-year level hurricane protection for southeastern Louisiana, the U.S. Army Corps of Engineers (USACE) has implemented design guidelines that both levees and structures shall be designed to. Historically, USACE has used concrete piles or steel H-piles as the foundations for these structures. Because of the magnitude of obtaining 100-year level hurricane protection, limited resources, and a condensed timeline, spiral welded pipe piles can be manufactured as an alternative to either the concrete piles or steel H-piles. This research will provide the necessary background for understanding pile foundations, will compare the behaviors of spiral welded pipe piles to that of other piles with respect to geotechnical concerns through a series of pile load tests, and will offer a current cost analysis. This background, testing, and cost analysis will show that spiral welded pipe piles are a viable alternative for USACE structures from a geotechnical and economic perspective.
13

Novo procedimento para a realização de análise capwap no ensaio de carregamento dinâmico em estacas pré-moldadas. / New prodedure to perform CAPWAP analysis on dinamic load test in precast concrete piles.

Murakami, Daniel Kina 01 October 2015 (has links)
Desde a década de 1980 diversos autores apresentaram correlações entre provas de carga estática e ensaios de carregamento dinâmico em estacas. Para uma boa correlação é fundamental que os testes sejam bem executados e que atinjam a ruptura segundo algum critério, como o de Davisson, por exemplo, além de levar em conta o intervalo de tempo entre a execução da prova de carga estática e do ensaio dinâmico, face ao efeito \"set up\". Após a realização do ensaio dinâmico realiza-se a análise CAPWAP que permite a determinação da distribuição do atrito lateral em profundidade, a carga de ponta e outros parâmetros dos solos tais como quakes e damping. A análise CAPWAP é realizada por tentativas através do procedimento \"signal matching\", isto é, o melhor ajuste entre os sinais de força medido pelos sensores e o calculado. É relativamente fácil mostrar que a mesma solução pode ser obtida através de dados de entrada diferentes. Isso significa que apesar de apresentarem cargas mobilizadas próximas o formato da curva da simulação de prova de carga estática, obtida pelo CAPWAP, assim como a distribuição do atrito lateral, podem ser diferentes, mesmo que as análises apresentem \"match quality\" (MQWU) satisfatórios. Uma forma de corrigir o formato da curva simulada do CAPWAP, assim como a distribuição do atrito lateral, é através da comparação com provas de carga estática (PCE). A sobreposição das duas curvas, a simulada e a \"real\", permite a determinação do quake do fuste através do trecho inicial da curva carga-recalque da prova de carga estática, que por sua vez permite uma melhor definição da distribuição do atrito lateral e da reação de ponta. Neste contexto surge o conceito de \"match quality de recalques\" (MQR). Quando a PCE não está disponível, propõe-se efetuar um carregamento estático utilizando o peso próprio do martelo do bate-estaca (CEPM). Mostra-se, através de dois casos de obra, em que estavam disponíveis ensaios de carregamento dinâmico e PCEs, que esse procedimento permite obter uma melhor solução do ponto de vista físico, isto é consistente com as características do subsolo e com a curva carga-recalque da PCE, e não apenas matemático, através da avaliação do \"match quality\" (MQWU). / Since the 1980s a lot of authors showed correlations between static load tests and dynamic load tests on piles. For a good correlation it is necessary a good execution of the load test, also it is necessary to choose a capacity value from the results of the static load test, for example, the Davisson Offset limit load. The time of execution between the static load test and the dynamic load test should be considered because of the set up effect. Dynamic data may be further analyzed by CAPWAP Method to evaluate the soil resistance distribution, the toe resistance, quake and damping values. It is a signal matching method. Its results are based on the \"best possible match\" between computed pile top variable such as the pile top force and its measured equivalent. It is easy to demonstrate almost the same pile capacity on CAPWAP using different soil parameters. It means that even the pile capacity is almost the same, the shape of the pile top load-displacement of the CAPWAP Method and the shaft friction distribution can be different, although all results confirm good match quality. One way to correct the shape of the top loaddisplacement of the CAPWAP Method, as well as the shaft friction distribution, is by comparisson to a static load test. Overlaying both curves, the static load test and the CAPWAP Method, it is possible to determine the shaft quake value on the initial loads on the top load-displacement curve, allowing this way a improvement of the shaft resistance distribution and the toe resistance. In this context arises the concept of \"match quality of settlements\". When the static load test is not avaliabe, this thesis proposes a static load test using the hammer\'s weight of the pile driving machine. It is shown by two case studies that were available static load tests and dynamic load tests, this procedure allows a better solution on physics aspects, this is consistent with the subsoil conditions and the load-settlement curve of the static load test, not only a mathematical solution based on match quality.
14

Novo procedimento para a realização de análise capwap no ensaio de carregamento dinâmico em estacas pré-moldadas. / New prodedure to perform CAPWAP analysis on dinamic load test in precast concrete piles.

Daniel Kina Murakami 01 October 2015 (has links)
Desde a década de 1980 diversos autores apresentaram correlações entre provas de carga estática e ensaios de carregamento dinâmico em estacas. Para uma boa correlação é fundamental que os testes sejam bem executados e que atinjam a ruptura segundo algum critério, como o de Davisson, por exemplo, além de levar em conta o intervalo de tempo entre a execução da prova de carga estática e do ensaio dinâmico, face ao efeito \"set up\". Após a realização do ensaio dinâmico realiza-se a análise CAPWAP que permite a determinação da distribuição do atrito lateral em profundidade, a carga de ponta e outros parâmetros dos solos tais como quakes e damping. A análise CAPWAP é realizada por tentativas através do procedimento \"signal matching\", isto é, o melhor ajuste entre os sinais de força medido pelos sensores e o calculado. É relativamente fácil mostrar que a mesma solução pode ser obtida através de dados de entrada diferentes. Isso significa que apesar de apresentarem cargas mobilizadas próximas o formato da curva da simulação de prova de carga estática, obtida pelo CAPWAP, assim como a distribuição do atrito lateral, podem ser diferentes, mesmo que as análises apresentem \"match quality\" (MQWU) satisfatórios. Uma forma de corrigir o formato da curva simulada do CAPWAP, assim como a distribuição do atrito lateral, é através da comparação com provas de carga estática (PCE). A sobreposição das duas curvas, a simulada e a \"real\", permite a determinação do quake do fuste através do trecho inicial da curva carga-recalque da prova de carga estática, que por sua vez permite uma melhor definição da distribuição do atrito lateral e da reação de ponta. Neste contexto surge o conceito de \"match quality de recalques\" (MQR). Quando a PCE não está disponível, propõe-se efetuar um carregamento estático utilizando o peso próprio do martelo do bate-estaca (CEPM). Mostra-se, através de dois casos de obra, em que estavam disponíveis ensaios de carregamento dinâmico e PCEs, que esse procedimento permite obter uma melhor solução do ponto de vista físico, isto é consistente com as características do subsolo e com a curva carga-recalque da PCE, e não apenas matemático, através da avaliação do \"match quality\" (MQWU). / Since the 1980s a lot of authors showed correlations between static load tests and dynamic load tests on piles. For a good correlation it is necessary a good execution of the load test, also it is necessary to choose a capacity value from the results of the static load test, for example, the Davisson Offset limit load. The time of execution between the static load test and the dynamic load test should be considered because of the set up effect. Dynamic data may be further analyzed by CAPWAP Method to evaluate the soil resistance distribution, the toe resistance, quake and damping values. It is a signal matching method. Its results are based on the \"best possible match\" between computed pile top variable such as the pile top force and its measured equivalent. It is easy to demonstrate almost the same pile capacity on CAPWAP using different soil parameters. It means that even the pile capacity is almost the same, the shape of the pile top load-displacement of the CAPWAP Method and the shaft friction distribution can be different, although all results confirm good match quality. One way to correct the shape of the top loaddisplacement of the CAPWAP Method, as well as the shaft friction distribution, is by comparisson to a static load test. Overlaying both curves, the static load test and the CAPWAP Method, it is possible to determine the shaft quake value on the initial loads on the top load-displacement curve, allowing this way a improvement of the shaft resistance distribution and the toe resistance. In this context arises the concept of \"match quality of settlements\". When the static load test is not avaliabe, this thesis proposes a static load test using the hammer\'s weight of the pile driving machine. It is shown by two case studies that were available static load tests and dynamic load tests, this procedure allows a better solution on physics aspects, this is consistent with the subsoil conditions and the load-settlement curve of the static load test, not only a mathematical solution based on match quality.
15

Prova de carga rápida com recalque estabilizado / Stabilized settlements by quick maintained load test

Marina Prearo Benvenutti Almeida 25 June 2009 (has links)
A prova de carga estática lenta é tradicional na engenharia de fundações, no mundo todo. Mas sua realização pode envolver um tempo excessivo e, por isso, tem havido tentativas para reduzir sua duração. O ensaio rápido, ao contrário, é realizado em apenas algumas horas, mas, sem dúvida alguma, os recalques obtidos nesse ensaio são bem inferiores aos do ensaio lento. Uma alternativa promissora pode ser o ensaio pelo método do equilíbrio, que parece reunir as vantagens daquelas duas modalidades. Nesse método, utiliza-se a carga mantida apenas no início do estágio e, depois, deixa-se a carga diminuir livremente até atingir uma condição de equilíbrio, com recalque e carga estabilizados, em cada estágio. Neste trabalho, são apresentadas comparações entre as três modalidades, em ensaios de placa, em modelo, em solo arenoso colapsível, em duas condições: inundado e não-inundado. / The slow mantained load is a traditional test in foundations engineering worldwide. Nevertheless, its implementation may take too long, so there have been attempts to reduce its duration. The quick mantained load test, in other hand, takes only a few hours to be accomplished and the obtained settlements are lower than the slow maintained load test. The method of equilibrium is an attractive option. It seems to combine the advantages of these two methods, using maintained load at the beggining of the stage and then allowing to freely decrease the load to reach its equilibrium. This study compares these three methods in two conditions: non-flooded and flooded colapsive sandy-soil model.
16

Prova de carga rápida com recalque estabilizado / Stabilized settlements by quick maintained load test

Almeida, Marina Prearo Benvenutti 25 June 2009 (has links)
A prova de carga estática lenta é tradicional na engenharia de fundações, no mundo todo. Mas sua realização pode envolver um tempo excessivo e, por isso, tem havido tentativas para reduzir sua duração. O ensaio rápido, ao contrário, é realizado em apenas algumas horas, mas, sem dúvida alguma, os recalques obtidos nesse ensaio são bem inferiores aos do ensaio lento. Uma alternativa promissora pode ser o ensaio pelo método do equilíbrio, que parece reunir as vantagens daquelas duas modalidades. Nesse método, utiliza-se a carga mantida apenas no início do estágio e, depois, deixa-se a carga diminuir livremente até atingir uma condição de equilíbrio, com recalque e carga estabilizados, em cada estágio. Neste trabalho, são apresentadas comparações entre as três modalidades, em ensaios de placa, em modelo, em solo arenoso colapsível, em duas condições: inundado e não-inundado. / The slow mantained load is a traditional test in foundations engineering worldwide. Nevertheless, its implementation may take too long, so there have been attempts to reduce its duration. The quick mantained load test, in other hand, takes only a few hours to be accomplished and the obtained settlements are lower than the slow maintained load test. The method of equilibrium is an attractive option. It seems to combine the advantages of these two methods, using maintained load at the beggining of the stage and then allowing to freely decrease the load to reach its equilibrium. This study compares these three methods in two conditions: non-flooded and flooded colapsive sandy-soil model.
17

Cravação de tubulões a céu aberto para melhoria da capacidade de carga em solos colapsíveis / Driving of belled piles to improve bearing capacity on collapsible soils

Benvenutti, Márcio 08 November 2001 (has links)
Os tubulões a céu aberto são amplamente utilizados como elementos estruturais de fundação de edifícios residenciais nas cidades pequenas e médias do Brasil. Relatam-se as etapas de um projeto de fundações por tubulões desenvolvido em uma área previamente ocupada por construções residenciais antigas. Após cuidadosa demolição e limpeza, deparou-se com o desafio de executar as fundações sem o perigo de danificar as construções adjacentes (tubulões à céu aberto de divisa nos dois lados e no fundo). No projeto, utilizaram-se procedimentos usuais e alguns específicos que refletem a prática corrente nos últimos 10 anos, na região de Campinas, com resultados extremamente satisfatórios. Nos solos porosos e colapsíveis, presentes em várias regiões brasileiras, as fundações não raramente têm apresentado comportamento inadequado, quando o solo é inundado. Com a significativa elevação do seu teor de umidade, esses solos exibem o recalque de colapso, caracterizando-se como colapsíveis. Como já se tem a comprovação da eficiência da compactação do solo para viabilizar o emprego de fundações rasas, por sapatas, em solos colapsíveis (CINTRA, 1998), resolveu-se estudar os possíveis benefícios da criação de tubulões a céu aberto. No campo experimental de Fundações da USP/São Carlos, foram executadas dois tubulões a céu aberto com fuste de diâmetro de 0,50 m e base apoiada à cota - 6,00 m, com diâmetro de 1,50 m e altura de 0,90 m. O primeiro tubulão a céu aberto foi ensaiado na condição não-inundada do solo, na cota inicial de apoio da base e sucessivamente, com a cravação de 0,15 m, 0,30 m e 0,45 m, o que corresponde a 10%, 20% e 30% do diâmetro da base, respectivamente. Observou-se que a cravação majorou a capacidade de carga em 42%, 85% e 12%, respectivamente. O segundo tubulão a céu aberto foi ensaiado com o solo pré-inundado, para quantificar o efeito da colapsibilidade do terreno na redução da capacidade de carga. ) Constatou-se uma redução de 51% a 53% nos valores de capacidade de carga anteriormente obtidos. Mas a carga de colapso, ou capacidade de carga na condição inundada, também teve uma majoração importante, aumentando em 45%, 90% e 135% com a cravação de 10%, 20% e 30% do diâmetro da base, respectivamente. Conclui-se que a cravação de tubulões a céu aberto, inicialmente executados com escavação e concretagem in situ, pode ser uma solução interessante em solos colapsíveis. / The belled piles are largely used as fundation for structural elements of residential buildings in small and medium cities in Brazil. The steps of a foundation design is developed in an area previously occupied by old residential buildings. After a careful demolition and clean up process, the challenger is to build the foundations without the danger of harming the adjacent buildings (Division of belled piles on both side and on the bottom). On the design, some specific and some standard procedures are used, which reflect the current practice over the last 10 years, in the Campinas region, with extremely satisfactory results . In porous and collapsible soil, that can be found in many Brazilian regions, these piles usually have presented an inadequate behavior, when the soil is soaked. With a significant elevation on its moisture content, these soils present the collapse settlement, being characterized as collapsible. Since there is already the confirmation of the compacting process efficacy in making the employment of shallow foundations on collapsible soils feasible (CINTRA, 1998), it was decided to study the possible benefits of driving the belled piles on the improvement of the bearing capacity. At the Experimental Foundation Field of USP/São Carlos, two piles were tested. Both piles were 6,00 m long and had a shaft diameter of 0.50 m. The enlarged bases had a diameter of 1.50 m and a height of 0.90 m. The first pile was tested under the non-soaked condition of the soil, on the initial quota of base support, and then with the 0.15 m, 0.30 m and 0.45 driving, which corresponds to 10%, 20%, and 30% of the base diameter, respectively. It was observed that the driving improved the bearing capacity in 42%, 85%, and 127%, respectively. The second pile was tested on a soaked soil, to quantity the collapsibility effect on the reduction of the bearing capacity. A reduction of 51% to 53% on the values of the bearing capacity previously obtained was observed, but the collapse load, also presented an important improvement, increasing 45%, 90%, and 135% with the driving of 10%, 20%, and 30% of the base diameter, respectively. We can conclude that the driving of belled piles, inittially executed with digging and concreting in situ, may be an interesting solution on collapsible soils.
18

Análise de provas de carga estática em estacas pré-moldadas cravadas na cidade de Curitiba e região metropolitana / Analysis of static loading tests in concrete drive pile carried out in Curitiba city and metropolitan area

Vianna, Ana Paula Fontana 29 June 2000 (has links)
Nesta dissertação são analisadas 34 provas de carga estática realizadas em estacas pré-moldadas de concreto, cravadas em diferentes locais da cidade de Curitiba e região metropolitana, sendo a maioria delas na Formação Guabirotuba. Três métodos de previsão da capacidade foram analisados: Aoki – Velloso (1975), Décourt – Quaresma (1978) e Amaral (1982, 1999). Para cada método foram propostos fatores de correção global e/ou parcial que tornam o valor da capacidade de carga mais próximo do valor da carga última obtida pelo critério de Van der Veen (1953). Com base em quatro provas de carga conduzidas até a ruptura, estudou-se a aplicabilidade do método de Van der Veen (1953) e determinou-se um critério para avaliar a extrapolação da curva carga x recalque em ensaios encerrados sem atingir a ruptura. Finalmente fez-se uma análise dos recalques comparando-se os valores medidos com os calculados, para três níveis de carregamento, além da comparação das curvas carga x recalque ajustadas com as experimentais. / This thesis presents the analysis of 34 static loading tests in concrete drive pile, located at different places of the Curitiba city and metropolitan area, in Guabirotuba Formation. Three methods of the bearing capacity prediction were assessed: Aoki – Velloso (1975), Décourt – Quaresma (1978) and Amaral (1982, 1999). For each method is proposed global correction factors and/or partial that turned the bearing capacity value close to the ultimate load obtained for the Van der Veen criteria (1953). Based on four static loading test carried out to failure, the applicability of the Van der Veen criteria was assessed and was determined a rule to evaluate the extrapolation of the load - settlement curve in tests stopped before of the failure. Finally, it was made an analysis of the settlements, where it was compared the observed values and the predicted values, for three loading level, and also a comparison between the experimental load-settlement curve and the predicted load-settlement curve.
19

Previsões do comportamento carga-recalque de estaca escavada com polímero / Prediction of Load-Displacement Behavior of Bored Pile with Polymer

Alves, Débora Fonseca January 2016 (has links)
O evento de previsões do comportamento carga-recalque de uma estaca executada em solo predominantemente arenoso foi apresentado no 8° Seminário de Engenharia de Fundações Especiais e Geotecnia (SEFE8). As previsões utilizaram sondagens CPT, DMT e SPT realizadas no campo experimental de Araquari, em Santa Catarina. A estaca utilizada para o evento foi do tipo escavada com polímero, diâmetro de 100cm e comprimento de 24m. Foram recebidos pelo comitê organizador 73 previsões provenientes de 20 países, com estimativas do comportamento carga-recalque da estaca, da capacidade de carga total, lateral e de ponta e a distribuição de carga ao longo do fuste até a ruptura, definida pelo recalque de 100 mm (w/D = 10%), com um resumo dos métodos e considerações. Os dados das previsões foram comparados aos resultados obtidos em campo pela prova de carga estática da estaca instrumentada. As previsões foram majoritariamente conservadoras e o ensaio mais utilizado para determinação dos parâmetros do solo foi o CPT, tanto no meio acadêmico quanto no prático Diversos métodos foram utilizados, porém mesmo previsões que utilizaram o mesmo método apresentaram variabilidades nos resultados. Baixos valores de desvio na capacidade de carga total não significaram pequenos desvios de lateral e de ponta, mas uma combinação de desvios positivos e negativos desses. A maioria das estimativas subestimou a capacidade lateral e superestimou a de ponta. O método de Verbrugge (1981) foi utilizado em duas das cinco previsões com menores desvios de capacidade total. As curvas carga-recalque e carga-profundidade foram avaliadas quanto aos desvios médios absolutos e formatos, dados pela variância. As curvas carga-recalque com médias de até 10% utilizaram Elementos Finitos e o software UniPile, e o menor valor de variância utilizou Verbrugge (1981). As curvas carga-profundidade com médias de até 10% utilizaram Verbrugge (1981), Randolph e Wroth (1978) e Gwizdala e Steczniewski (2003), e o menor valor de variância utilizou o software UniPile. / The prediction event of load-settlement behavior of a pile built in predominantly sandy soil was presented at the 8th Foundation Engineering Seminar and Special Geotechnical (SEFE8). The predictions used tests of CPT, DMT and SPT accomplished in Araquari experimental field, in Santa Catarina. A bored pile with polymer, diameter of 100cm and length of 24m was the subject of the event. The organizing committee received 73 predictions from 20 countries, with estimates of load-settlement behavior of the pile, the total, shaft and base load capacity and the load distribution along the shaft until failure, defined by settlement of 100 mm (W/D = 10%), with a brief description of methods and considerations. Data from the predictions were compared to the results obtained in the field by static load test of the instrumented pile. The predictions were mostly conservative and the test most used for soil parameters prediction was the CPT, both in academia as in practice. Several methods were used, but even predictions that used the same method showed variability in the results Low error values in the total load capacity not meant small shaft and base errors, but a combination of positive and negative errors of these. Most estimates underestimated the shaft capacity and overestimated the base. The Verbrugge (1981) method was used in two of five predictions with lower errors of total capacity. The curves were analyzed for absolute average deviation and formats, evaluated by the variance. The load-settlement distribution with average up to 10% used Finite Element and UniPile software, and the lowest value of variance used Verbrugge (1981). The load-depth distribution with average up to 10% used Verbrugge (1981), Randolph and Wroth (1978) and Gwizdala and Steczniewski (2003), and the lowest value of variance used the UniPile software.
20

Utilização de penetrômetro manual em solo colapsível e comparação com resultados de provas de carga em placa e em sapata / The utilization of a hand penetrometer in a collapsible soil and comparison with load tests in plate and in footing

Tsuha, Cristina de Hollanda Cavalcanti 26 September 2003 (has links)
O presente trabalho tem como objetivo avaliar a utilização de um penetrômetro manual para quantificar a resistência à penetração em um solo poroso e não-saturado. Os ensaios foram efetuados com monitoração de sucção, obtendo-se assim correlações entre resistência à penetração do penetrômetro e a sucção do solo. Os valores de tensão de ruptura obtidos nos ensaios penetrométricos foram comparados com valores de capacidade de carga de ensaios de placa e de provas de carga em sapatas realizados à mesma profundidade, no mesmo local, com medidas simultâneas de sucção. Finalmente, o trabalho comprova a influência da sucção nos resultados dos ensaios realizados / The objective of this work is to evaluate the use of a hand penetrometer to quantify the penetration resistance of a porous and unsaturated soil. The tests were done with suction monitoring, thus, it was obtained correlation between resistance of the penetrometer penetration and the soil suction. The values of rupture pressure obtained by the penetrometer tests were compared with values of bearing capacity of plate load tests and footing load tests, that were done at the same deep and at the same location, with suction measurement. Finally, this work proves the influence of the suction on the tests results

Page generated in 0.0706 seconds