• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 3
  • 1
  • Tagged with
  • 14
  • 7
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modelo multicritério de apoio à decisão para identificação de pontos candidatos à instalação de dispositivos sinalizadores de faltas no sistema de distribuição de energia elétrica.

Simões, Evandro Monteiro 31 January 2012 (has links)
Made available in DSpace on 2014-06-12T17:42:58Z (GMT). No. of bitstreams: 2 arquivo9600_1.pdf: 1113997 bytes, checksum: da3add9ad6c7cab9dbfe9ab2c3ec2e2b (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2012 / O propósito deste trabalho é apresentar uma contribuição referente ao desenvolvimento de um modelo de priorização de um investimento em tecnologia, visando melhorar a disponibilidade das redes de distribuição primária de energia. Na busca da melhoria da prestação do serviço de distribuição, será proposto um modelo que utiliza uma ferramenta de decisão multicritério, chamado PROMETHEE II. Este modelo busca um ordenamento das alternativas do problema de decisão em questão. Este ordenamento, no contexto do modelo proposto, indicará a priorização dos equipamentos mais críticos dentro do âmbito de uma concessionária de energia elétrica e com maior potencial de utilização de dispositivos de localizadores de falta da rede de distribuição. Os localizadores de falta são dispositivos capazes de indicar o trecho de circuito por onde passou uma corrente de curto-circuito ou sobrecarga, e a sua utilização estratégica possibilitam uma normalização mais ágil do serviço de distribuição para os circuitos onde instalado
2

Modelo multicritério de apoio a decisão para identificação de pontos candidatos à instalação de dispositivos sinalizadores de faltas no sistema de distribuição de energia elétrica

Simões, Evandro Monteiro 30 January 2012 (has links)
Submitted by João Arthur Martins (joao.arthur@ufpe.br) on 2015-03-05T16:59:07Z No. of bitstreams: 2 ems.pdf: 1113997 bytes, checksum: da3add9ad6c7cab9dbfe9ab2c3ec2e2b (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-05T16:59:07Z (GMT). No. of bitstreams: 2 ems.pdf: 1113997 bytes, checksum: da3add9ad6c7cab9dbfe9ab2c3ec2e2b (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2012-01-30 / O propósito deste trabalho é apresentar uma contribuição referente ao desenvolvimento de um modelo de priorização de um investimento em tecnologia, visando melhorar a disponibilidade das redes de distribuição primária de energia. Na busca da melhoria da prestação do serviço de distribuição, será proposto um modelo que utiliza uma ferramenta de decisão multicritério, chamado PROMETHEE II. Este modelo busca um ordenamento das alternativas do problema de decisão em questão. Este ordenamento, no contexto do modelo proposto, indicará a priorização dos equipamentos mais críticos dentro do âmbito de uma concessionária de energia elétrica e com maior potencial de utilização de dispositivos de localizadores de falta da rede de distribuição. Os localizadores de falta são dispositivos capazes de indicar o trecho de circuito por onde passou uma corrente de curto-circuito ou sobrecarga, e a sua utilização estratégica possibilitam uma normalização mais ágil do serviço de distribuição para os circuitos onde instalado.
3

Diseño, Construcción e Integración de un Módulo de Interfaz Digital Análogo para Sistemas Repetidores de Globo Sonda Usados en Situaciones de Emergencia

Abarca Mesa, Ignacio Andrés January 2011 (has links)
Memoria para optar al título de Ingeniero Civil Electricista / En esta memoria se propone un diseño para un módulo de interfaz digital-análogo, usado como modem, codificador y decodificador. Su función es enviar y recibir información digital a través de un canal de audio en radiofrecuencia. Se presenta además el estudio y análisis de la factibilidad técnica de este diseño. En periodos de catástrofe o en lugares aislados los servicios de emergencia y seguridad requieren plataformas de comunicación exclusivas, portables y de bajo costo (en lo posible desechables). Como eventual solución se plantean globos aerostáticos y/o vehículos aéreos autónomos (UAVs) de bajo costo que puedan actuar como repetidor de comunicación de audio. Sin embargo la posición GPS de estos objetos es necesaria para el monitoreo y toma de decisiones de la comunicación haciendo necesario un módulo interfaz que permita transmitir los datos digitales de la posición a través de este canal de audio. En particular el objetivo de este trabajo es el desarrollo de un prototipo del módulo interfaz que incluye tanto hardware como software. El hardware del módulo está compuesto principalmente por un microcontrolador y un modem de audio, mientras que el software de comunicación se basa en el protocolo APRS. En este documento se especifica el diseño del software y de los algoritmos que manejan el protocolo y las funcionalidades del sistema. El hardware de bajo costo, el cual es requisito para esta solución, dificulta el uso de protocolos de comunicación estándares dado el ruido y distorsiones de las señales que este producen. Debido a esto el software de comunicación debe ser más robusto que los protocolos usuales. El nuevo protocolo presentado en este trabajo cambia la estrategia de muestreo y decodificación de los datos. Finalmente se realiza un análisis funcional del software que controla el hardware del módulo. Los resultados de desempeño del módulo son presentados junto con estrategias de mejoras futuras.
4

Collares geolocalizadores para mascotas vinculados a una aplicación móvil / Pet locator necklace linked to a mobile application

Aguirre Pacheco, Catherine Fiorella, Aguero Solano, Jean Pooul, Felix Cabanillas, Eliana Brigitte, Landeo Salazar, Jimena Alexandra, Wong Mendoza, Anthony Juseb 01 July 2019 (has links)
En la actualidad existe la tendencia de humanizar a las mascotas, y cada año que pasa las personas destinan una mayor cantidad de sus ingresos hacia el cuidado de ellos, como en salud, belleza y moda. Sin embargo, a la par de este crecimiento, también se encuentran las pérdidas o robos de los animales. Tan solo en el Perú se pierden alrededor de 420,000 mascotas al año, de las cuales sólo el 18% regresan con sus dueños. La idea de negocio que se está presentando consiste en un collar geolocalizador para mascotas que estará vinculado a una aplicación móvil a través de la cual se podrá saber las 24 horas del día la ubicación exacta de quien utilice el dispositivo. El nombre de la empresa es Geopet, que además contará con un geocerco con el que se podrá establecer un perímetro de dónde no puede salirse el aparato; y en caso lo traspasara, llegará automáticamente una alerta al celular del dueño indicando hacia qué dirección debe ir a buscarlo. Sin embargo, las funciones no sólo se centran en el localizador, sino en brindarles algo más a los usuarios, por lo que también cuenta con una red social en la que los dueños de mascotas podrán interactuar y subir información de sus perros o gatos. El principal motivo para la creación de Geopet es disminuir la pérdida de mascotas en la ciudad de Lima Metropolitana y mantener la seguridad de quienes hoy en día también forma parte fundamental de las familias. / Currently, there is a tendency to humanize pets, and each year people spend a greater amount of their income on caring for them, such as health, beauty and fashion. However, along with this growth, there are also losses or thefts of Animals. Only in Perú, around 420,000 pets per year are lost, of wich only 18% return with their owners. The business idea that is being presented consists of a geolocalizer collar for pets that will be linked to a mobile application through wich you can know the extact location of who uses the device, the 24 hours a day. The name of the Company is Geopet, wich will also have a fence with wich a perimeter can be established from where the device can not leave; and in case it happens, an alert will automatically arrive at the owner`s cell indicating wich direction the animal is leaving. However, the functions not only focus on the locator, but to provide something more to users, so it also has a social network in wich pet owners can interact and upload information about their dogs or cats. The main reason for the creation of Geopet is to reduce the loss of pets in the city of Lima Metropolitana and maintain the safety of those who are now a day fundamental part of families. / Trabajo de investigación
5

Desempenho de um sistema localizador de sinais num ambiente com ruído

Silva, Luís Filipe de Almeida January 2012 (has links)
Tese de mestrado. Mestrado Integrado em Engenharia Electrotécnica e de Computadores. Faculdade de Engenharia. Universidade do Porto. 2012
6

Estudo cl?nico da acur?cia da localiza??o eletr?nica na constri??o apical e respectiva concord?ncia radiogr?fica / Clinical study of the accuracy of electronic location in constriction apical and their respective radiographic agreement

Fernandes, Vanessa Cruz Silva 29 August 2014 (has links)
Submitted by Nivaldo Melo (nivaldo.melo@ufvjm.edu.br) on 2015-11-19T16:55:42Z No. of bitstreams: 2 vanessa_cruz_silva_fernandes.pdf: 1170469 bytes, checksum: 4c17b7d56cb5f5b99dca08404cbe93c5 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Rodrigo Martins Cruz (rodrigo.cruz@ufvjm.edu.br) on 2015-11-19T17:53:53Z (GMT) No. of bitstreams: 2 vanessa_cruz_silva_fernandes.pdf: 1170469 bytes, checksum: 4c17b7d56cb5f5b99dca08404cbe93c5 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2015-11-19T17:53:54Z (GMT). No. of bitstreams: 2 vanessa_cruz_silva_fernandes.pdf: 1170469 bytes, checksum: 4c17b7d56cb5f5b99dca08404cbe93c5 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2014 / Introdu??o: Terapeuticamente a constri??o apical ? refer?ncia do comprimento de trabalho (CT) dos canais radiculares (CR). Objetivo: Avaliar clinicamente fatores associados ? acur?cia do localizador apical eletr?nico (LAE) Apex Finder A.F.A. 7005 na determina??o da constri??o apical. Metodologia: Para cada CR, uma lima tipo Kerr selecionada e acoplada ao LAE foi inserida intracanalmente at? obter est?vel marca??o, 1 mm no painel digital (LCD). Na radiografia periapical correspondente ? dist?ncia da ponta da lima ao v?rtice dent?rio foi categorizada como precisa (0.5 a 1.5 mm), aceit?vel (0 a 2 mm) ou imprecisa (demais medidas). A concord?ncia foi analisada em fun??o do grupo de dentes, estado pulpar e periapical, di?metro do CR e di?metro da lima explorat?ria. A influ?ncia das vari?veis independentes foi analisada pelos testes Mann-Whitney, Kruskal-Wallis e Correla??o de Sperman (p<0,05). Resultados: Os dentes anteriores (n=21), pr?-molares (n=20) e molares (n=33) proveram 147 CR, dos quais 43.5% eram atr?sicos. Em 102 (69,4%) a polpa estava necr?tica, dentre os quais 70 (47,6%) apresentavam radiolucidez periapical. Obteve-se elevada concord?ncia entre a medida eletr?nica e radiogr?fica. Verificou-se que 70,7% e 94,5% das medidas foram do tipo precisas ou aceit?veis, respectivamente. A acur?cia das medidas correlacionou-se positivamente com as limas explorat?rias e negativamente com o di?metro do CR. Nenhuma vari?vel independente influenciou a acur?cia do LAE (p>0.05). Conclus?o: O Apex Finder proveu medidas de CT com elevada aceitabilidade cl?nica na regi?o da constri??o apical, independentemente do estado pulpar, grupo dentes, estado periapical ou di?metro dos canais radiculares. / Disserta??o (Mestrado) ? Programa de P?s-Gradua??o em Odontologia, Universidade Federal dos Vales do Jequitinhonha e Mucuri, 2014. / ABSTRACT of root canals (RC). Objective: To evaluate clinically associated factors with the accuracy of the electronic apex locator (EAL) Apex Finder A.F.A. 7005 in determination of apical constriction. Methodology: For each RC, one selected file type Kerr and coupled at EAL was inserted intracanal until stablished marking, 1 mm on the liquid-crystal display (LCD). The periapical radiograph correspondent the distance of the file tip to the tooth apex was classified as specify (0.5 to 1.5 mm), acceptable (0 to 2 mm) or imprecise (other steps). The agreement was analyzed according to the group of teeth, pulpal and periapical status, RC diameter and exploratory file diameter. The influence of independent variables was analyzed by Mann-Whitney, Kruskal-Wallis and Spearman correlation (p <0.05) tests. Results: The anterior teeth (n=21), premolars (n=20) and molars (n=33) provided RC 147, of which 43.5% were atresic. In 102 (69.4%) the pulp was necrotic, among which 70 (47.6%) had periapical radiolucency. High agreement between the electronic and radiographic measurement was obtained. It was found that 70.7% and 94.5% of the measurements are accurate and acceptable type, respectively. The accuracy of measurements correlated positively with exploratory files and negatively with the diameter of RC. No independent variable influenced the accuracy of LAE (p> 0.05). Conclusion: The Apex Finder provided measures of WL with high clinical acceptability in apical constriction, regardless of status pulp, tooth group, periapical status or diameter of the root canals.
7

GPS PETS: más que un localizador de mascotas / GPS PETS: much more than a pet tracker

Bullón Sánchez, Leslie Margarita, Burgos Chumpitazi, Melissa Rocio, Melendez Perez, Fiorella Carolina 14 July 2020 (has links)
El objetivo del presente trabajo es demostrar la viabilidad de un negocio orientado al rastreo satelital de mascotas a través de un microchip insertado en los canes, el cual se encuentra ligado a un aplicativo móvil que ofrece servicios adicionales como la ubicación de veterinarias y pet shops aledaños, así como un historial de paseadores de perros calificados. Para ello, se detalla el planeamiento estratégico que incluye un análisis interno y externo de la organización. Asimismo, se explican los resultados de la investigación de mercado. También, se precisan los planes de marketing, operaciones, económico-financiero y la estructura organizacional, junto con la gestión de recursos humanos. En la investigación, se utiliza tanto la metodología cualitativa como la cuantitativa. Los resultados indican la viabilidad del negocio, así como su aceptación por parte del público objetivo y su rentabilidad para los accionistas e inversionistas de la empresa. Se concluye, por lo tanto, que el modelo de negocio de GPS PETS es viable, alcanzable y expandible en el mercado peruano. / The aim of this project is to prove the viability of a business created to track pets through a microchip inserted in dogs, which is linked to a mobile application that also offers certain services such as the location of pet shops and vet centers nearby. It also contains a list of dog walkers who are highly qualified. Therefore, a strategic planning is listed, which includes an internal and external analysis of the organization. Plus, the results of the market research are explained in detail. Moreover, the marketing, economic, and operational plans are described along with the organizational structure and the human resources management. In this investigation, the quantitative and qualitative research methods are used. The results indicate the viability of this business, as well as its acceptance by the target market, and its profitability for the company’s shareholders and investors. To sum up, it is concluded that GPS PETS business model is achievable, sustainable and expandable in the Peruvian market. / Trabajo de investigación
8

Influência da espessura de dentina, da constrição apical e do diâmetro do forame apical na precisão de leitura com localizadores foraminais eletrônicos / Influence of dentin thickness, apical constriction and diameter of the apical foramen in the accuracy of readings with electronic apex locators.

Orosco, Fernando Accorsi 19 November 2010 (has links)
Este trabalho teve como objetivo avaliar a influência da espessura de dentina radicular apical, da constrição apical e do diâmetro do forame apical na precisão de leituras realizadas com os localizadores foraminais eletrônicos Mini Apex Locator e Root ZX II®. Foram utilizados 30 incisivos inferiores permanentes unirradiculados de humanos, extraídos, com raízes íntegras e ápices completamente formados e portadores de um único canal. Por meio de um paquímetro, as espessuras radiculares dos dentes foram medidas, no sentido mésio-distal a 1,0 e a 4,0mm aquém do forame apical. Após a abertura coronária, uma lima tipo K no 10, munida de limitador de penetração, foi introduzida no canal radicular até que sua extremidade pudesse ser visualizada na altura do forame, com o auxílio de um microscópio óptico com aumento de 7,8X. Dessa medida, subtraiu-se 1,0mm, estabelecendo-se o comprimento de trabalho. A dilatação do canal radicular foi feita, inicialmente, com brocas de Gates Glidden, em ordem numérica decrescente, da número 5 até a número1, até 4,0mm aquém do forame apical. Os dentes foram fixados em um modelo experimental especialmente desenvolvido para permitir a medição com os localizadores foraminais eletrônicos. Tal modelo era constituído por dois segmentos de PVC: um de menor calibre, com diâmetro correspondente a meia polegada por 2,0cm de comprimento, com as duas extremidades abertas e outro, de maior calibre, com uma das extremidades fechada e com diâmetro interno equivalente ao diâmetro externo do primeiro segmento (3/4 de polegada). No segmento de maior diâmetro, foi feito um orifício lateral que permitiu o posicionamento do eletrodo labial do localizador foraminal eletrônico e, para a medição, no seu interior, foi colocado alginato e, então, encaixado o componente de menor diâmetro, fazendo com que o ápice radicular ficasse imerso no alginato. Foram realizadas as leituras com os localizadores, iniciando-se com a lima tipo K no 10 e seguindo-se a seqüência de instrumentação e medida até a lima tipo K no 130; a lima tipo K no 10 foi utilizada em todos os diâmetros. Terminada essa fase, os dentes tiveram os canais sobreinstrumentados, isto é, a ponta da lima ultrapassou o forame apical em 1,0mm, a partir da lima tipo K no 25 e seguindo até a lima tipo K no 130; novas medidas foram obtidas com cada lima que sobreinstrumentou o forame e a lima no 10 foi utilizada em todos os diâmetros. Em todos os casos o canal radicular estava preenchido com hipoclorito de sódio a 1%. Para a análise estatística foram empregados os testes de Análise de Variância a dois critérios e de Tukey. Os resultados indicaram que as variáveis capazes de influenciar a recisão das leituras com os localizadores foraminais eletrônicos foram a eliminação da constrição apical com o consequente aumento do diâmetro do forame apical, ao contrário da espessura da parede dentinária do canal radicular, que não interferiu significativamente na precisão das leituras. / This study evaluated the influence of the apical root dentin thickness, apical constriction and diameter of the apical foramen in the accuracy of readings obtained using the electronic apex locators Mini Apex Locator and Root ZX II ®. The study was conducted on 30 extracted human single-rooted permanent mandibular incisors, with intact and completely formed roots and presenting a single canal. The root thickness of the teeth was measured with a pachymeter in mesiodistal direction, at 1.0 and 4.0mm from the apical foramen. After coronal opening, a 10 K file with a stop was introduced in the root canal until its end could be observed at the level of the apical foramen, with aid of a light microscope with 7.8X magnification. One millimeter was subtracted from this measurement for establishment of the working length. Enlargement of the root canal was initially performed using Gates Glidden burs, in decreasing order, from number 5 to number 1, up to 4.0mm beyond the apical foramen. The teeth were fixated in an experimental model especially designed to allow the measurement with the electronic apex locators. This model was composed of two PVC segments: one smaller, with diameter corresponding to half inch with 2.0cm length, with both ends open; and the other, with larger diameter, with one end closed and internal diameter similar to the external diameter of the first segment (3/4 inch). In the segment with greater diameter, a lateral orifice was made to allow positioning of the lip electrode of the electronic apex locator. For the measurement, alginate was poured and the component with smaller diameter was fitted, so as the root apex was immersed in alginate. Readings were performed using the electronic apex locators, initiating with a 10 K file and following the sequence of instrumentation and measurement up to 130 K file. The 10 K file was used in all diameters. After this stage, the root canals were overinstrumented, i.e. the file tip was introduced until 1.0mm beyond the apical foramen, beginning with 25 K file up to 130 K file; new measurements were obtained with each file overinstrumenting the apical foramen, and the 10 K file was used in all diameters. In all cases, the root canal was irrigated with 1% sodium hypochlorite. Statistical analysis was performed by two-way analysis of variance and the Tukey test. The results indicated that the variables that may influence the accuracy of readings with the electronic apex locators were the elimination of apical constriction with consequent increase in the diameter of the apical foramen, different from the thickness of the root canal dentinal wall, which did not significantly influence the accuracy of readings.
9

Influência da espessura de dentina, da constrição apical e do diâmetro do forame apical na precisão de leitura com localizadores foraminais eletrônicos / Influence of dentin thickness, apical constriction and diameter of the apical foramen in the accuracy of readings with electronic apex locators.

Fernando Accorsi Orosco 19 November 2010 (has links)
Este trabalho teve como objetivo avaliar a influência da espessura de dentina radicular apical, da constrição apical e do diâmetro do forame apical na precisão de leituras realizadas com os localizadores foraminais eletrônicos Mini Apex Locator e Root ZX II®. Foram utilizados 30 incisivos inferiores permanentes unirradiculados de humanos, extraídos, com raízes íntegras e ápices completamente formados e portadores de um único canal. Por meio de um paquímetro, as espessuras radiculares dos dentes foram medidas, no sentido mésio-distal a 1,0 e a 4,0mm aquém do forame apical. Após a abertura coronária, uma lima tipo K no 10, munida de limitador de penetração, foi introduzida no canal radicular até que sua extremidade pudesse ser visualizada na altura do forame, com o auxílio de um microscópio óptico com aumento de 7,8X. Dessa medida, subtraiu-se 1,0mm, estabelecendo-se o comprimento de trabalho. A dilatação do canal radicular foi feita, inicialmente, com brocas de Gates Glidden, em ordem numérica decrescente, da número 5 até a número1, até 4,0mm aquém do forame apical. Os dentes foram fixados em um modelo experimental especialmente desenvolvido para permitir a medição com os localizadores foraminais eletrônicos. Tal modelo era constituído por dois segmentos de PVC: um de menor calibre, com diâmetro correspondente a meia polegada por 2,0cm de comprimento, com as duas extremidades abertas e outro, de maior calibre, com uma das extremidades fechada e com diâmetro interno equivalente ao diâmetro externo do primeiro segmento (3/4 de polegada). No segmento de maior diâmetro, foi feito um orifício lateral que permitiu o posicionamento do eletrodo labial do localizador foraminal eletrônico e, para a medição, no seu interior, foi colocado alginato e, então, encaixado o componente de menor diâmetro, fazendo com que o ápice radicular ficasse imerso no alginato. Foram realizadas as leituras com os localizadores, iniciando-se com a lima tipo K no 10 e seguindo-se a seqüência de instrumentação e medida até a lima tipo K no 130; a lima tipo K no 10 foi utilizada em todos os diâmetros. Terminada essa fase, os dentes tiveram os canais sobreinstrumentados, isto é, a ponta da lima ultrapassou o forame apical em 1,0mm, a partir da lima tipo K no 25 e seguindo até a lima tipo K no 130; novas medidas foram obtidas com cada lima que sobreinstrumentou o forame e a lima no 10 foi utilizada em todos os diâmetros. Em todos os casos o canal radicular estava preenchido com hipoclorito de sódio a 1%. Para a análise estatística foram empregados os testes de Análise de Variância a dois critérios e de Tukey. Os resultados indicaram que as variáveis capazes de influenciar a recisão das leituras com os localizadores foraminais eletrônicos foram a eliminação da constrição apical com o consequente aumento do diâmetro do forame apical, ao contrário da espessura da parede dentinária do canal radicular, que não interferiu significativamente na precisão das leituras. / This study evaluated the influence of the apical root dentin thickness, apical constriction and diameter of the apical foramen in the accuracy of readings obtained using the electronic apex locators Mini Apex Locator and Root ZX II ®. The study was conducted on 30 extracted human single-rooted permanent mandibular incisors, with intact and completely formed roots and presenting a single canal. The root thickness of the teeth was measured with a pachymeter in mesiodistal direction, at 1.0 and 4.0mm from the apical foramen. After coronal opening, a 10 K file with a stop was introduced in the root canal until its end could be observed at the level of the apical foramen, with aid of a light microscope with 7.8X magnification. One millimeter was subtracted from this measurement for establishment of the working length. Enlargement of the root canal was initially performed using Gates Glidden burs, in decreasing order, from number 5 to number 1, up to 4.0mm beyond the apical foramen. The teeth were fixated in an experimental model especially designed to allow the measurement with the electronic apex locators. This model was composed of two PVC segments: one smaller, with diameter corresponding to half inch with 2.0cm length, with both ends open; and the other, with larger diameter, with one end closed and internal diameter similar to the external diameter of the first segment (3/4 inch). In the segment with greater diameter, a lateral orifice was made to allow positioning of the lip electrode of the electronic apex locator. For the measurement, alginate was poured and the component with smaller diameter was fitted, so as the root apex was immersed in alginate. Readings were performed using the electronic apex locators, initiating with a 10 K file and following the sequence of instrumentation and measurement up to 130 K file. The 10 K file was used in all diameters. After this stage, the root canals were overinstrumented, i.e. the file tip was introduced until 1.0mm beyond the apical foramen, beginning with 25 K file up to 130 K file; new measurements were obtained with each file overinstrumenting the apical foramen, and the 10 K file was used in all diameters. In all cases, the root canal was irrigated with 1% sodium hypochlorite. Statistical analysis was performed by two-way analysis of variance and the Tukey test. The results indicated that the variables that may influence the accuracy of readings with the electronic apex locators were the elimination of apical constriction with consequent increase in the diameter of the apical foramen, different from the thickness of the root canal dentinal wall, which did not significantly influence the accuracy of readings.
10

Proposta de um algoritmo eficiente para a localização de faltas por relé diferencial numérico para proteção de linhas de transmissão com compensação série controlada por tiristores (TCSC) /

Taquire, Nelson Romero January 2016 (has links)
Orientador: Jose Sanches Mantovani / Resumo: Neste trabalho propõe-se um método para a localização de faltas que, em conjunto com a lógica de um relé diferencial numérico, deve ser usado para proteção de linhas de transmissão com compensação série controlada por tiristores (TCSC). Este método visa solucionar o problema de localização de faltas melhorando a precisão dos algoritmos que utilizam medições de sinais de tensão e corrente numa terminação da linha de transmissão. O cálculo da distância entre a terminação da linha de transmissão e o ponto de incidência da falta é realizado utilizando dois procedimentos: um para faltas produzida no trecho entre a terminação local da linha de transmissão e o TCSC; e o outro para faltas no trecho entre o TCSC e a terminação remota. A detecção do trecho de incidência da falta é obtido usando as medições de escorregamento angular dos sinais de corrente em ambos os extremos da linha de transmissão e a medição da resistência de falta no extremo local, que é variável durante o intervalo de início até um ciclo depois da ocorrência da falta. A aplicação da lógica difusa na comparação destas medições permite detectar com precisão o trecho com falta. O método proposto foi testado usando um sistema teste da literatura onde múltiplos casos de faltas em diferentes pontos da linha de transmissão foram simulados. Os resultados mostram a capacidade do algoritmo em localizar precisamente a posição de ocorrência da falta. / Abstract: This paper proposes a methodology for locating faults in transmission lines with thyristor-controlled series compensation (TCSC) that are protected by numerical differential relays. The proposed methodology aims to overcome problems of fault location improving the accuracy of algorithms that use voltage and current measurement signals from a transmission line termination. The calculation of the distance between the transmission line termination and the fault incidence point employs two procedures: one for faults in the transmission line section limited by the local termination and TCSC; and other for faults in the section limited by the TCSC and remote termination. The detection of the fault incidence section is achieved using measurements of angular deviation for both transmission line terminations and the measurement of fault resistance in the local termination, which varies during the interval from the beginning to one cycle after the fault occurrence. The use of fuzzy logic for comparing these measurements permits the accurate detection of the fault incidence section. The proposed method is tested using a test system from literature system where multiple fault cases in different positions of the transmission line are simulated. The results show the algorithm capability to locate accurately the position of fault occurrence. / Mestre

Page generated in 0.0586 seconds