• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 41
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 43
  • 43
  • 43
  • 30
  • 28
  • 28
  • 18
  • 16
  • 14
  • 13
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Luminescência opticamente estimulada com aplicações em radioterapia: dependência da dose absorvida e da energia de fótons produzidos em aceleradores clínicos e Microtron - IFUSP / Optically stimulated luminescence with applications in radiotherapy: dependence of absorbed dose and photon energy produced on clinical accelerators and Microtron - IFUSP

Carlos Eduardo Freitas 28 April 2017 (has links)
Atualmente a utilização de fótons de raios X e gama na Medicina (radiodiagnóstico e radioterapia) gerou a necessidade do conhecimento da dose absorvida nos tecidos dos pacientes. Para isso, utiliza-se detectores com diversas funcionalidades a fim de conhecer a deposição de energia. Para ser possível a utilização destes materiais, é necessário caracterizá-los tanto quanto à resposta em função da dose absorvida, quanto à dependência com a energia. Neste trabalho foi estudada a dependência energética da resposta OSL dos dosímetros compostos por BeO e Al2O3 em feixes de raios X convencional com espectro largo, feixes de raios X de aceleradores clínicos e do acelerador Microtron do Instituto de Física da USP e fontes gama de Cs-137 e Co-60, em uma faixa de doses desde centenas de mGy até aproximadamente 2 Gy. Foram utilizadas em conjunto simulações em Monte Carlo com o código PENELOPE, que simula o transporte de fótons e elétrons na matéria, a fim de conhecer a deposição de energia nos materiais. Os espectros utilizados nas simulações foram validados através da comparação das características dos feixes tais como a deposição de dose com a profundidade, camada semirredutora, energia média e resolução espectral. Utilizando um sistema de varredura por câmara de ionização controlado remotamente, foi estudada a distribuição de doses no campo de irradiação para definir uma região de irradiação com dose uniforme para pode realizar a irradiação de um conjunto de dosímetros simultaneamente. Foram encontrados valores do fator de dependência energética experimental para os feixes mais energéticos (Co-60, Microtron 5 MeV e aceleradores clínicos de 6 e 15 MeV), com desvio menor que 3% para o Al2O3 e 5% para o BeO, indicando independência com a energia do feixe de irradiação. Já nos feixes de baixa energia, os fatores de dependência energética relativos à energia do Co-60 para o Al2O3 foram de 1,68 e 1,42, e, para o BeO, de 0,78 e 0,90 para os feixes W150 e W200 respectivamente. Estes valores indicam que, nesta faixa de energia, a resposta OSL depende mais fortemente da energia do feixe. As simulações em Monte Carlo feitas para os fatores de dependência energética se mostraram bem consistentes com os valores experimentais para o BeO em toda faixa de energia e para o Al2O3, excetuando-se os feixes de baixa energia, possivelmente pelo não completo conhecimento de todos os elementos constituintes do dosímetro empregado (fita de Luxel®). Quanto às curvas de emissão OSL para as diferentes energias de irradiação, foi observado que o sinal decai mais rápido quanto mais elevada é a energia média do feixe para o BeO. Para o Al2O3, o efeito foi mais sutil e oposto. Os estudos do feixe do Microtron mostraram que, desde que a corrente seja monitorada durante as irradiações para posterior correção da dose, é possível realizar estudos utilizando um feixe de fótons de Bremsstrahlung produzido com alvo externo e energias médias (simuladas e ainda não validadas experimentalmente) próximas às energias das fontes gama de Cs-137 e Co-60. Os resultados experimentais para as respostas OSL dos dois materiais foram compatíveis com as simulações. / Nowadays the use of X and gamma-ray photons in Medicine (radiodiology and radiotherapy) has generated the necessity of knowing the absorbed dose to the tissues of patients. For this purpose, detectors with diverse functionalities are used to know the energy deposition. To make possible the use of these materials, it is necessary to characterize the dose response, as well as the energy dependence of the response. In this work the energy dependence of the OSL response of the BeO and Al2O3 dosimeters was studied for conventional X-ray beams with wide energy spectrum, X-ray beams from clinical accelerators and from the Microtron accelerator of the Institute of Physics (University of São Paulo), and for gamma sources of Cs-137 and Co-60, in a dose range from hundreds of mGy to about 2 Gy. Monte Carlo simulations were used with the PENELOPE code, which simulates the photons and electrons transport of in the matter, to know the energy deposition in the materials. The energy spectra used in simulations were validated by comparison with beam characteristics such as depth dose deposition, half-value layer, mean energy and spectral resolution. Using a remotely controlled ionization chamber scanning system, the dose distribution within the irradiation field was evaluated to define a uniform dose region for irradiation or a set of dosimeters simultaneously. Experimental energy dependence factor values were obtained for the high-energy beams (Co-60, Microtron 5 MeV, and clinical accelerators of 6 and 15 MeV), with a deviation of less than 3% for Al2O3 and 5% for BeO, indicating independence with the beam energy. For the low-energy X-ray beams, the energy dependence factors, relative to the Co-60 energy, for Al2O3 were 1.68 and 1.42, and, for BeO, 0.78 and 0.90 for W150 and W200 beams respectively. These values indicate that, in this energy range, the OSL response depends on beam energy. Monte Carlo simulations for the energy dependence factors were consistent with experimental values for the BeO in entire energy range and for the Al2O3, with the exception of low energy beams, possibly due to the incomplete knowledge of all the elements that constitute the Luxel®. As for the shape of OSL emission curves for the different irradiation energies, it was observed that the signal decays faster the higher is the average beam energy for BeO. For Al2O3, the effect was more subtle and opposite. The Microtron beam scanning has shown that, as long as the current is monitored during irradiation for further dose-rate correction, it is possible to carry out studies using a beam of Bremsstrahlung photons produced with external target and mean energies (simulated but still not validated experimentally) close to the energies of the Cs-137 and Co-60 sources. The experimental results for the OSL responses of both materials were compatible with simulations.
22

Dosimetria usando luminecência opticamente estimulada: aplicações, propriedades físicas e caracterização de materiais dosimétricos / Dosimetry using optically stimulated luminescence: applications, physical properties and dosimeter detectors characterization

Luana de Freitas Nascimento 10 August 2007 (has links)
Dosimetria usando Luminescência Opticamente Estimulada (OSL) é uma área em constante crescimento dentro da ciência e com excelentes perspectivas comerciais. O Óxido de Alumínio crescido na presença de uma atmosfera rica em Carbono (Al 2O3:C) tem fornecido bons resultados como detector luminescente. Esse material apresenta alta sensibilidade à radiação ionizante e boa resposta à estímulos ópticos. Estima-se que cerca de dois milhões de pessoas façam uso de dosímetros com detectores de Al 2O3:C em rotinas de dosimetria individual externa, que por apresentar varias vantagens experimentais acredita-se substituirá as outras duas técnicas dosimétricas mais adotadas: dosimetria fotográfica e termoluminescente. A certificação de uma técnica de dosimetria para uso comercial exige uma série de estudos. Neste trabalho apresentamos contribuições que complementam o entendimento e adoção da técnica de OSL em dosimetria pessoal. Nossa primeira contribuição consiste numa serie de testes de desempenho mostrando a eficácia da técnica para justificar nossa proposta de certificação de dosimetria individual externa usando OSL no Brasil. No intuito de relacionar centros paramagnéticos e o processo de luminescência, apresentamos resultados de espectros de EPR em detectores OSL. Detectamos e classificamos sinais de EPR relacionados a impurezas nas amostras, porem, sinais dos centros luminescentes não foram detectados. Finalmente, apresentamos um estudo preliminar sobre a resposta de luminescência do Al2O3:C quando exposto a diferentes comprimentos de onda de radiação UV. A inexistência de dosimetria de nêutrons por técnicas de OSL motivou o estudo de vários óxidos dopados com Térbio como possíveis candidatos a material dosimétrico. Alguns resultados preliminares do espectro de EPR desses óxidos quando irradiados em campo beta de 90Sr/90Y e da resposta de luminescência em função da luz de excitação para análise dos tipos de armadilhas criadas pela presença do Tb+3 são apresentados. / Dosimetry using Optically Stimulated Luminescence (OSL) is an expanding scientific research area which also shows excellent commercial potential. Aluminum oxide grown in an atmosphere in the presence of Carbon, Al 2O3:C, presented excellent results as a luminescent detector. This material has high sensitivity when exposed to ionizing radiation and good responses to optical stimulation. Over two million people use dosimeters with Al 2O3:C detectors in personal dosimetry procedures. The experimental advantages of using OSL are believed to replace the two other usual techniques: photographic and thermoluminescent dosimetry. To validate the commercial use of a dosimetry technique it is necessary to evaluate a number of studies. In this work we present results which increase our understanding of OSL dosimetry. First we present a number of behavior tests to show the efficiency of the technique for the purpose of justifying the use of OSL in personal dosimetry in Brazil. In an attempt to correlate paramagnetic centers and the luminescence process we present EPR results in OSL detectors. We could detect and classify impurities centers in our samples; however we could not find conclusive results about paramagnetic centers generated by exposition to ionizing radiation. We present a preliminary study about the luminescence behavior from Al 2O3:C when exposed to different UV wavelengths. The nonexistence of a neutron dosimetry using OSL suggested a study of three types of oxides doped with Terbium which are strong candidates as OSL detectors due to their sensitivity to neutron expositions. We present preliminary results of EPR spectroscopy from these oxides when exposed in a beta field of 90Sr/90Y and the luminescent response when the excitation light is used to analyze traps generated by the presence of Tb+3.
23

Sedimentologia e cronologia por luminescência da Ilha de São Francisco do Sul (SC): considerações sobre a evolução holocênica de barreiras arenosas da costa sul e sudeste do Brasil

André Zular 29 September 2011 (has links)
A ilha de São Francisco do Sul (ISFS) está localizada no litoral norte de Santa Catarina. Abrange uma área de cerca de 265 km2 com uma extensão de costa oceânica de aproximadamente 40 km. A ISFS foi formada por sistemas deposicionais costeiros ativos durante as variações do nível do mar dos últimos 120 mil anos. A progradação costeira da barreira regressiva localizada a leste da lagoa de Icaraí da ISFS estaria associada à desaceleração da ascensão do nível relativo do mar do Holoceno médio combinada com um aporte alto de sedimentos. Características geomorfológicas da SFSI foram analisadas principalmente com o auxílio do Google Earth e com levantamentos de campo que indicaram a prevalência de sobreposição de dunas vegetadas formadas pela influência dos ventos S-SE na parte central e norte da barreira holocênica. Ao longo da costa, predomina uma estreita faixa de 5 a 10 m de dunas frontais associadas com swales. Em direção ao interior, as dunas frontais são gradualmente substituídas por blowouts e/ou dunas parabólicas de 10 a 20 m de altura ou por dunas com formatos irregulares seguidos por alinhamentos de cordões litorâneos. Foram feitas datações de 11 amostras de sedimentos através de luminescência opticamente estimulada (LOE); cinco de cordões litorâneos, cinco de dunas parabólicas e uma de blowout numa área total de 7 km2 . As datações demonstraram que a construção da barreira mediante progradação de cordões litorâneos sem atividade eólica significativa ocorreu no período entre 4900 a pelo menos 3100 anos atrás. A partir de 1900 anos atrás, a progradação da barreira passou a ocorrer com o desenvolvimento de dunas parabólicas, cuja estabilização teria ocorrido até cerca de 1200 anos atrás. A sensibilidade LOE do quartzo foi estimada nas alíquotas analisadas para avaliar o retrabalhamento dos sedimentos nas diferentes unidades geomorfológicas. As amostras mais antigas dos cordões litorâneos mostraram valores elevados de sensibildade LOE que indicam sedimentos muito retrabalhados, possivelmente submetidos a vários ciclos de deposição e de erosão. Análise granulométrica e de minerais pesados foram realizadas em 45 amostras. Os cordões litorâneos foram caracterizados por areias finas e por uma assembléia metamórfica de minerais pesados em contraste com as dunas parabólicas, blowouts e areias da praia atual onde predominam sedimentos de granulometria média e uma maior contribuição de proveniência de rochas plutônicas ácidas. A progradação holocênica da barreira da ISFS teve uma mudança acentuada na morfodinâmica há cerca de 1900 a 1800 anos atrás, caracterizada pelo desenvolvimento episódico das dunas parabólicas migrando para o NW sobrepostas aos cordões litorâneos e a uma mudança acentuada na proveniência dos sedimentos. Essa mudança morfodinâmica é associada a um aumento na força dos ventos de sul e a maior intensidade da deriva litorânea rumo ao norte. Esses fatores indicam o fortalecimento das frentes frias a partir de 1900 a 1800 anos atrás. A maior atividade das frentes frias no sul do Brasil pode estar relacionada com a expansão para o norte da faixa de ação dos ventos de oeste (Westerlies) e intensificação do El Niño/Oscilação Sul (ENOS). A alterações geomorfológicas e de proveniência detectadas na ISFS demonstram que as barreiras holocênicas do sul e sudeste do Brasil são sensíveis à mudanças climáticas do Holoceno Tardio. Assim, a geocronologia e sedimentologia de fácies geomorfológicas, como demonstradas em uma pequena área de SFSI, podem atuar como um indicador válido de eventos climáticos do passado. / São Francisco do Sul Island (SFSI) is located on the northern coast of Santa Catarina State, Brazil. It covers an area of about 265 km2 with an approximate length of oceanic coastline of 40 km. The island was formed by coastal depositional systems active during the relative sea-level changes of the last 120,000 years. The following relative sea -level fall after the Mid-Holocene maximum highstand combined with high sediment input have contributed to coastal progradation of the regressive barrier located eas t of Icaraí lagoon. Geomorphological features of SFSI were analyzed primarily with the aid of Google Earth and field surveys and indicated the prevalence of superimposed vegetated dunes formed under the influence of the S-SE winds on the central and northern part of the Holocene barrier. Along the coastline, a narrow belt of 5-10 m high foredune ridges associated with swales occurs. The foredunes are gradually replaced inland by blowouts and/or 10-20 m high parabolic or irregular dune forms followed by beach ridges. Optically Stimulated Luminescence (OSL) dating of 11 samples using the single-aliquot regenerative-dose (SAR) protocol of the beach ridges (5 samples), parabolic dunes (5 samples) and blowouts (1 sample) over an area of 7 km2 showed two distinct periods of stabilization. Beach ridges stabilized at the 4.9-3.1 ka period and parabolic dunes at the 1.9-1.2 period. Quartz OSL sensitivity was measured in the dating aliquots to evaluate the sedimentary reworking of sands from the studied geomorphological units. Elevated OSL-sensitivity values associated with the oldest beach ridge samples indicate highly reworked sediments, possibly submitted to many cycles of barrier construction and erosion. Grain-size and heavy minerals analyses were performed in 45 samples. Beach ridges were characterized by fine sands and a metamorphic heavy minerals assemblage in contrast to the parabolic dunes, blowouts and present beach sands of medium grain-size and a higher contribution of an acid plutonic rocks provenance. The Holocene progradation of the SFSI barrier had a pronounced morphodynamic shift around 1.9-1.8 ka, which is characterized by the episodic development of the parabolic dunes migrating to NW over beach ridges and a marked change in sediment provenance. This morphodynamic shift derived from an increase in the strength of winds from south and northward alongshore drift, implied strengthening of cold fronts activity since 1.9-1.8 ka. Higher cold fronts activity in Southern Brazil can be linked with the northward expansion of the south westerly wind belt (Westerlies) and intensification of El Niño Southern Oscilation (ENSO). Thus, the luminescence chronology and sedimentology of different geomorphological facies in barrier systems as shown in a small area of SFSI may act as a valid proxy for past climate events.
24

Síntese e caracterização de elemento sensor de matriz KAISi3O8, dopadas com Mn ou Gd, obtidos pela técnica sol-gel, visando a aplicação em dosimetria das radiações ionizantes por termoluminescência e luminescência opticamente estimulada. / Synthesis and caracterization of sensor element of kalSi3O8 matrix, doped with mn and gd, obtained by sol-gel method, for application in ionizing radiation dosimetry by thermoluminescence and optically stimulated luminescence.

Elcio Liberato Pires 12 November 2010 (has links)
Neste trabalho, estudou-se as propriedades termoluminescentes e fotoluminescentes (em processo anti-Stokes), além de algumas propriedades químicas e físicas, de amostras sintéticas de KAlSi3O8, dopadas com Mn ou Gd, obtidas por meio da técnica sol-gel. O objetivo principal do estudo foi a obtenção de um novo material, com possibilidades reais de aplicação em dosimetria das radiações ionizantes, como elemento sensor de dosímetros luminescentes. As amostras foram obtidas e trabalhadas na forma de pós com tamanho médio de partícula em 600 nm e suas estruturas composta por uma matriz amorfa e com presença de nano partículas, presente apenas nas amostras dopadas. Os resultados de EPR mostraram que os dopantes incorporaram na matriz sob a valência de Mn2+ e Gd3+ respectivamente. As curvas de emissão TL apresentaram formatos semelhantes para todas as regiões estudadas, com a presença de um pico principal de intensidade alta e reprodutível em torno de 170°C. As curvas de decaimento da LOE da amostra não dopada e dopada com Mn exibiram um decaimento total da luminescência para 40 s de estimulação centrada em 470 nm; por outro lado, a amostra dopada com Gd, exibiu um rápido decaimento da LOE (aproximadamente 71,4 % da intensidade inicial), para os primeiros 40 s de estimulação, seguida por um decaimento mais lento e persistente para o restante do período de estimulação, o que indica claramente a presença de duas componentes de decaimento. As amostras dopadas com Mn apresentaram emissão TL mais intensa em torno 570 nm, sendo mais eficientes para os estudos de TL no VIS; enquanto que, as dopadas com Gd, exibiram emissão mais intensa em 470 nm, porém, devido ao formato dos sinais (presença de um único pico aparente), mostraram-se melhor para os estudos de LOE e TL no UV. As amostras dopadas com 0,5% e 8% em mol de Mn e Gd, respectivamente, apresentaram os sinais luminescentes mais intensos, tanto para LOE quanto para TL. No estudo da dependência energética para diferentes energias de raios-X, o tipo de dopante influenciou no padrão de resposta obtido, tendo sido observado um decréscimo da intensidade luminescente com o aumento da energia para a amostra dopada com Mn; para a amostra não dopada e dopada com Gd, não se observou um padrão de decréscimo ou aumento da intensidade com a energia. As curvas de calibração foram ajustadas por meio de retas com grau de confiabilidade alto (fator R2 próximo a 1), e as menores doses detectáveis variaram entre 20 e 60 mGy aproximadamente. Todas as amostras apresentaram perdas consideráveis de intensidade luminescente com o passar do tempo após irradiação, e que foi de aproximadamente 80%, em média, para os 10 primeiros dias. Concluiu-se que, a princípio, os materiais têm maior possibilidade de aplicação na dosimetria em tempo real do que na dosimetria convencional ou passiva por TLDs, devido a sua alta resposta luminescente. Contudo, estudos futuros a respeito de tratamento térmico prévio, podem viabilizá-los a esta última aplicação. Com relação ao campo de aplicação, sugere-se a dosimetria ambiental, devido aos valores Z obtidos, que estão mais próximos do dos materiais que compões rochas e sedimentos. / In this work the thermoluminescent and photoluminescent properties (in the anti-Stokes process), and some other chemical and physical properties of KAlSi3O8 synthetic samples, doped with Mn or Gd, obtained by sol-gel method, were studied. The main goal of this study was to obtain a new material, with real possibility of application in ionizing radiation dosimetry as sensor element in luminescent dosimeters. The obtained samples were composed of powders with average particle size around 600 nm and they structures were composed of an amorphous matrix with presence of nanoparticles, observed only in the doped samples. The EPR results showed that the dopants incorporated in the matrix in the Mn2+ and Gd3+ valences, respectively. The TL glow curves exhibited a similar pattern for all the studied regions, composed of a main high-intensity and reproducible peak around 170 °C. The OSL shine-down curves for the undoped and Mn doped samples exhibited a total decay of luminescence for 40 s of stimulation centered at 470 nm; on the other hand, Gd doped sample exhibited an quick OSL decay (approximately 71.4 % of the initial intensity), for the first 40 s of stimulation, followed by a slower and more persistent decay, which clearly indicates the presence of two decay components. Mn doped samples showed the highest TL emission around 570 nm, being more efficient for the TL studies in the VIS, while the Gd doped samples exhibited the highest emission at 470 nm; however, due to the obtained curve pattern (with an apparent single peak), they had shown more efficient results for the applications in the UV. The samples doped with 0.5 and 8 mol% of Mn and Gd, respectively, showed the highest luminescent response improvement for OSL and TL. Energetic dependence on different X-rays energies study showed that the dopants changed the obtained response pattern. The Mn doped sample exhibited a decrease in luminescent response, while the Gd and the undoped samples do not show a pattern of decrease or increase in luminescence. The calibration curves were fitted by straight lines with high reliability degree (R2 near to 1), and the lowest detectable doses were between 20 and 60 mGy. All the samples exhibited considerable losses in luminescent intensity with the time after irradiation (about 80% for the firsts 10 days). From the results it was concluded that the studied materials are more applicable to real time than to passive TLD dosimetry, due to their high luminescent response. However, studies about previous heating treatment could make them feasible for the last application. The use of these materials in environmental dosimetry is suggested due to the obtained Z values, which are closer to those which form rocks and sediments.
25

Estabelecimento de padronização primária e de métodos relativos com o uso de técnicas luminescentes em dosimetria da radiação beta / Establishment of primary standardization and relative methods with the use of luminescent techniques in beta radiation dosimetry

Antonio, Patrícia de Lara 19 February 2014 (has links)
Devido à inexistência de um laboratório de padronização primária na América Latina, para calibração e dosimetria de fontes de radiação beta, neste trabalho uma câmara de extrapolação Böhm foi caracterizada e estabelecida como um sistema padrão primário no Laboratório de Calibração de Instrumentos (LCI) do IPEN. Como objetivo principal deste trabalho, a câmara de extrapolação Böhm foi caracterizada com relação à sua resposta em feixes padrões secundários de radiação beta de fontes de 90Sr+90Y, com duas janelas de entrada diferentes: Mylar aluminizado e Hostaphan grafitado, e com dois métodos de determinação de taxa de dose absorvida, para verificação do seu desempenho com cada material. Embora se trate do instrumento mais adequado para a calibração de detectores e fontes de radiação beta, a câmara de extrapolação deve ser utilizada apenas em laboratórios de calibração e não em programas de controle de qualidade, pois ela tem 7 kg e é de alto custo. Assim, é importante ter sistemas considerados padrões de trabalho e métodos alternativos para substituir a câmara de extrapolação em medições realizadas em campo, como em hospitais ou clínicas. Por este motivo, foram caracterizadas três câmaras de ionização de placas paralelas, com o objetivo de se verificar a possibilidade de seu uso como sistemas padrões de trabalho em programas de controle de qualidade, e também foram estudados materiais dosimétricos diferentes, em campos de radiação beta de 90Sr+90Y, utilizando-se os fenômenos da termoluminescência (TL) e da luminescência opticamente estimulada (LOE), como métodos alternativos na calibração de fontes de radiação beta. Inclui-se aqui o desenvolvimento de um sistema postal dosimétrico para a calibração de aplicadores clínicos de 90Sr+90Y. Os resultados obtidos com a câmara de extrapolação Böhm permitiram o seu estabelecimento como sistema padrão primário na calibração de fontes de 90Sr+90Y, pois a câmara com as duas janelas de entrada diferentes permitiram a determinação de taxas de dose absorvida no ar e no tecido, à profundidade nula e a 0,07 mm. A caracterização das três câmaras de ionização de placas paralelas mostraram que elas podem ser usadas em programas de controle de qualidade de fontes de radiação beta, pois suas respostas se apresentaram adequadas para esta finalidade. Os materiais dosimétricos testados com relação às suas respostas TL e LOE também se mostraram adequados para uso em campos de radiação beta, pois suas respostas foram satisfatórias. O sistema dosimétrico, utilizando dosímetros TL, foi testado em hospitais e, posteriormente, foi enviado na forma postal a um laboratório, contendo detectores TL e LOE, e o resultado da calibração dos aplicadores clínicos foi adequado. / Due to the lack of a primary standard laboratory at the Latin America, for the calibration and dosimetry of beta radiation sources, it was decided to establish the Böhm extrapolation chamber at the Calibration Laboratory (LCI) at IPEN as a primary standard. As a main objective of this work, the Böhm extrapolation chamber was characterized in relation to its response in beta radiation secondary standard beams of 90Sr+90Y sources, using two different entrance windows: aluminized Mylar and graphited Hostaphan, and using two methods of determination of absorbed dose rates, to verify its performance in each material. Although it is the most adequate instrument for the calibration of beta radiation detectors and sources, the extrapolation chamber should only be used at calibration laboratories, and not in quality control programs, because it weights 7 kg, and it is expensive. Thus, it is important to have systems considered work standards and alternative methods to replace the extrapolation chamber in measurements performed outside laboratories, such as in hospitals and clinics. For this reason, three parallel plate ionization chambers were characterized, with the objective to verify the possibility of their use as work standard systems, and different dosimetric materials were also studied, in beta radiation fields, using the thermoluminescence (TL) and optically stimulated luminescence (OSL) phenomena, as alternative methods for the calibration of beta radiation sources. The development of a dosimetric postal system for the calibration of 90Sr+90Y clinical applicators was included in this objective. The results obtained using the Böhm extrapolation chamber allowed its establishment as a primary standard system at the calibration of 90Sr+90Y sources, because it was possible to determine the absorbed dose rates in air and in the tissue, at null depth and 0.07 mm using the chamber with the two different entrance windows. The characterization of the three parallel plate ionization chambers showed that they can be used in quality control programs of beta radiation sources, because their responses were adequate to this purpose. The dosimetric materials were tested in relation to their TL and OSL response, and their use showed also to be adequate in beta radiation fields. The dosimetric postal system, using TL dosimeters, was tested in hospitals, and afterwards, it was sent to a laboratory, by conventional mail, with TL and OSL detectors, and the results of the calibration of the clinical applicators was adequate.
26

Proveniência sedimentar do Grupo Guaritas, Cambriano da Bacia de Camaquã (RS) / Sedimentary Provenance of the Guaritas Group, Cambrian from the Camaquã Basin, Southern Brazil

Nobrega, Jorge Emanuel dos Santos 25 April 2011 (has links)
O Grupo Guaritas (Eocambriano da Bacia do Camaquã, RS) é formado por rochas siliciclásticas, predominantemente arenosas e conglomeráticas, interpretadas como de origem aluvial e eólica. Esta unidade estratigráfica pode apresentar mais de 1500 m de espessura de sedimentos e abrange as formações Guarda Velha, Pedra das Torrinhas, Varzinha, Pedra Pintada e Serra do Apertado. O Grupo Guaritas relaciona-se a importantes eventos geológicos do sul do Brasil, pois registra o encerramento da sedimentação em bacia extensional do tipo rifte (Bacia do Camaquã) durante o Cambriano, a qual se desenvolveu em área que seria posteriormente recoberta por ampla bacia intracratônica (a Bacia do Paraná), a partir do Ordoviciano. Para contribuir com novas informações sobre a proveniência das unidades eopaleozóicas brasileiras, as rochas arenosas do Grupo Guaritas foram submetidas à análise de minerais pesados, petrografia de lâminas delgadas e luminescência opticamente estimulada (LOE). As análises de minerais pesados foram realizadas na fração areia muito fina de 44 amostras coletadas em afloramentos. Essas análises abrangeram a identificação e quantificação da assembléia de minerais pesados transparentes não-micáceos, além da determinação dos índices ZTR (zircão+turmalina+rutilo), ATi (apatita/(apatita+turmalina)), ZTi (zircão/(turmalina+zircão)) e ZRi (zircão/(rutilo+zircão). As seções delgadas foram utilizadas para descrever os componentes deposicionais e diagenéticos e para classificar os arenitos estudados. Quatro amostras selecionadas foram submetidas ainda à análise da sensibilidade LOE de grãos individuais de quartzo. A sensibilidade LOE foi calculada utilizando a integral da curva LOE assim como de seus componentes, chamados informalmente de rápido, médio e lento. A sensibilidade LOE foi usada para avaliação de grau de retrabalhamento sedimentar. As amostras estudadas foram classificadas como arcóseos, subarcóseos e sublitoarenitos. Os minerais pesados identificados e suas porcentagens médias foram: zircão (36%), turmalina (13%), rutilo (3%), apatita (23%), granada (16%), anatásio (7%), titanita (1%), sillimanita (1%), monazita (<1%), epidoto (<1%), hornblenda (<1%), estaurolita (<1%) e cianita (<1%). Esses minerais pesados foram descritos em todas as unidades estudadas do Grupo Guaritas. Os valores médios do índice ZTR variam de 20 (Fm. Serra do Apertado) a 40 (Fm. Pedra Pintada) enquanto que o índice ZTi apresenta valores médios entre 62 (Fm. Guarda Velha) e 73 (Fm. Pedra Pintada). Os valores médios dos índices ZRi e ATi variam de 81 (Fm. Guarda Velha) a 90 (Fm. Varzinha) e de 79 (Fm. Guarda Velha) a 83 (Fm. Serra do Apertado), respectivamente. As médias da sensibilidade LOE total do quartzo apresentaram valores médios maiores para as unidades inferiores (Fm. Guarda Velha = 3295 contagens e Fm. Varzinha = 3655 contagens) em relação às superiores (Fm. Pedra Pintada = 2271contagens e Fm. Serra do Apertado = 2457 contagens). As médias dos componentes LOE rápido (15-19%), médio (37-38%) e lento (43-46%) não apresentam diferenças marcantes entre as unidades. A assembléia de minerais pesados dominada por zircão, apatita e turmalina sugere que os sedimentos arenosos do Grupo Guaritas são derivados principalmente de rochas ígneas ácidas (granitos neoproterozóicos). A pequena variação do índice ZRi aponta manutenção da configuração litológica da área-fonte durante a deposição das unidades estudadas. A abundância de feldspatos, fragmentos líticos e, principalmente, de apatita indica deposição em ambiente árido e/ou soterramento rápido. Isto é coerente com a sensibilidade LOE do quartzo, que é relativamente reduzida, indicando baixo grau de retrabalhamento sedimentar para as areias do Grupo Guaritas. A sensibilidade LOE mais elevada das areias da Formação Guarda Velha representaria maior contribuição de sedimentos distais mais retrabalhados.A sensibilidade LOE do quartzo permite avaliar o grau de retrabalhamento de sedimentos antigos (Cambriano), já que até então este método tinha sido aplicado somente à sedimentos quaternários. / The Guaritas Group (Eocambrian of the Camaquã Basin, southern Brazil) is mainly composed of fine to coarse-gravelly sandstones, interpreted as a record of fluvial and aeolian depositional systems. This stratigraphic unity may present more than 1500m thick of sediments, comprising the Guarda Velha, Pedra das Torrinhas, Varzinha, Pedra Pintada and Serra do Apertado formations. The Guaritas Group relates to important geological events occurred in southern Brazil during the Eopaleozoic. Its deposition marks the final episode of sedimentary filling of an extensional rift basin (Camaquã Basin) during the Cambrian, in an area after covered by a huge intracratonic basin (Paraná Basin) during the Ordovician. To contribute with new information about the provenance of Eopalaezoic Brazilian sediments, the sandy rocks of the Guaritas Group were analyzed through heavy minerals, thin section petrography and luminescence methods. Heavy minerals analyses were carried out in the very fine sand fraction of 44 rock samples collected from outcrops. These analyses included the identification and quantification of the transparent non-micaceous heavy minerals as well as the determination of the ZTR (zircon+tourmaline+rutile), ATi (apatite/(apatite+tourmaline)), ZTi (zircon/(tourmaline+zircon)) and ZRi (zircon/(rutile+zircon) indices. Thin section petrography was used to describe depositional and diagenetic components and classify the studied sandstones. Further, four samples were selected for measurements of optically stimulated luminescence (OSL) sensitivity in quartz single-grains. The OSL sensitivity was calculated using the total OSL curve as well as specific components, informally named fast, medium and slow. The OSL sensitivity of quartz has been used as a proxy for sedimentary reworking. The studied sandstones were classified as arkoses, subarkoses and sublitharenites. The identified heavy minerals and their mean percentages were: zircon (36%), tourmaline (13%), rutile (3%), apatite (23%), garnet (16%), anatase (7%), titanite (1%), sillimanite (1%), monazite (<1%), epidote (<1%), hornblende (<1%), staurolite (<1%) and kyanite (<1%). These heavy minerals were described in all studied units of the Guaritas Group. The mean values of the ZTR indice varied from 20 (Serra do Apertado Fm.) to 40 (Pedra Pintada Fm.) while the ZTi indice presented mean values between 62 (Guarda Velha Fm.) and 73 (Pedra Pintada Fm.). The mean values of the ZRi and ATi indices ranged from 81 (Guarda Velha Fm.) to 90 (Varzinha Fm.) and from 79 (Guarda Velha Fm.) to 83 (Serra do Apertado Fm.), respectively. The total OSL sensitivity of quartz demonstrated higher mean values for the bottom units (Guarda Velha Fm. = 3295 counts; Varzinha Fm. = 3655 counts) than for the upper units (Pedra Pintada Fm. = 2271 counts, and Serra do Apertado Fm. = 2457 counts). The means of the fast OSL component (15-19%), medium (37-38%) and slow (43-46%) did not differ markedly among the units. The heavy minerals assemblage dominated by zircon, tourmaline and apatite suggests that the sandy sediments of the Guaritas Group are mainly derived from acid igneous rocks (neoproterozoic granites).The low range of variation of the ZRi indice points out the maintenance of similar primary source rocks during the deposition of the Guaritas sediments. The abundance of unstable grains such as feldspars, lithic fragments and apatite indicates deposition under arid climate and/or high rate of sediment accumulation. The OSL sensitivity of quartz grains is relatively low, suggesting sands with low degree of reworking. This is compatible with the high content of unstable sand grains (apatite, feldspar and lithic fragments) and elevated rate of sediment accumulation. The greater proportion of grains with higher OSL sensitivity in the Guarda Velha Formation represents an increased contribution of sediments from distal more reworked sources.The OSL sensitivity of quartz allows evaluate the degree of reworking of older sediments (Cambrian), since this method had been applied only to Quaternary sediments.
27

Luminescência opticamente estimulada em condições de ressonância plasmônica / Optically stimulated luminescence under plasmon resonance conditions

Guidelli, Éder José 27 April 2015 (has links)
A luminescência opticamente estimulada (OSL) é a luminescência emitida por um material, isolante ou semicondutor, durante exposição à luz e que foi previamente exposto à radiação ionizante. Portanto, depende da quantidade de cargas armadilhadas na estrutura do material, o que por sua vez depende da dose de radiação absorvida pela amostra. Dessa forma, a busca por novos materiais para serem utilizados como detectores de radiação envolve a criação de defeitos que atuem como armadilhas e/ou centros luminescentes. Recentemente, as interações entre os plásmons de nanopartículas metálicas e centros luminescentes têm sido utilizadas para aumentar a intensidade luminescente emitida por diversos materiais. Nesse trabalho, foi investigada a possibilidade de aplicação das propriedades plasmônicas de nanoestruturas de prata e ouro, no aumento da emissão OSL. Para isso, foram testados como dosímetros OSL, compósitos de cloreto de sódio contendo nano e micropartículas de prata; compósitos de óxido de zinco contendo nanopartículas de ouro e prata; e amostras de cloreto de sódio depositado sobre filmes de nanopartículas de prata e ouro. As amostras foram caracterizadas por diversas técnicas como espectroscopia UV-Vis, espalhamento dinâmico de luz, espectroscopia na região do infravermelho, espectroscopia de fotoluminescência, microscopia eletrônica de transmissão, microscopia de força atômica, entre outras. Foi possível verificar que a intensificação dos campos elétricos locais em torno de nanopartículas metálicas em condições de ressonância plasmônica aumenta a taxa de desarmadilhamento de elétrons durante a estimulação OSL. O acoplamento plasmônico causou aumento das taxas de decaimento radiativo e redução das taxas de decaimento não radiativo, produzindo aumento da intensidade OSL. Além disso, as interações entre as armadilhas/centros luminescentes e os plásmons variam de acordo com a distância entre as partes, e a maior intensidade OSL foi obtida para amostras em que houve um espaçamento de aproximadamente 15 nm entre o NaCl o filme de nanopartículas de prata. Portanto, é possível utilizar as propriedades plasmônicas de nanoestruturas metálicas para aumentar a intensidade da luminescência opticamente estimulada, dando origem a novos e mais sensíveis detectores e dosímetros das radiações ionizantes. / Optically stimulated luminescence (OSL) is a well-known light emission process involving light stimulation of an insulator/semi-conductor material previously exposed to ionizing radiation. The intensity of the emitted light is proportional to the ionizing radiation dose previously absorbed by the material. Developing appropriate OSL materials for radiation detection and dosimetry is based on the doping and co-doping of a host material to create defects that can act as traps and/or luminescent centers. In this context, plasmon interaction with luminescent centers from OSL materials could be a new, different, and unexplored method to achieve enhanced OSL intensity and consequently improve their sensitivity as radiation detectors. In this study, we investigated whether it is possible to use the plasmonic properties of noble metal nanoparticles to obtain plasmon-enhanced OSL. To this end, we produced samples of NaCl containing nano and microparticles; composites of ZnO containing silver and gold nanoparticles; as well as samples of NaCl deposited over films of gold and silver nanoparticles. Each sample has been tested as a radiation detector by means of optically stimulated luminescence, in addition to having their materials properties analyzed by UV-Vis absorption spectroscopy, dynamic light scattering, transmission electron microscopy (TEM), atomic force microscopy, and Fourier Transform Infrared spectroscopy (FTIR). We discovered that the electric field intensification around nanoparticles under plasmon resonance conditions enhances the excitation rate of trapped electrons. The plasmon coupling during the emission process increases the radiative and diminishes the non-radiative decay rates, leading to enhanced OSL intensities. Furthermore, the interaction between traps/luminescent centers and plasmons is highly dependent on the distance between them, and the maximum OSL intensity was observed for samples with 15 nm spacing between the NaCl and the silver nanoparticle films. Therefore, it is possible to use the plasmon properties of metal nanostructures to increase OSL, giving rise to new and more sensitive ionizing radiation detectors and dosimeters.
28

Rearranjos de drenagem na bacia do Rio Capivari e morfogênese da Serra do Mar em São Paulo (SP): uma contribuição ao estudo de capturas fluviais em meio tropical úmido / Drainage rearrangements in the Capivari River basin and morphogenesis of Serra do Mar in São Paulo (SP): a contribution to the study of stream captures in a humid tropical environment

Santos, André Henrique Bezerra dos 05 October 2017 (has links)
A pesquisa teve como objetivo compreender o papel dos rearranjos de drenagem à evolução do relevo e da drenagem na bacia hidrográfica do Rio Capivari, situada no reverso da Serra do Mar, em São Paulo-SP. Parte-se da hipótese de que esses fenômenos seriam responsáveis por inúmeras anomalias de drenagem observadas, como: inflexões em ângulos retos, padrões de drenagem anômalos, colos, rupturas em perfis longitudinais e subdimensionamento de cursos dágua em relação aos vales. Especial ênfase foi dada à inflexão do alto Rio Capivari, localizada na confluência com o Ribeirão Embura, possível remanescente de uma captura fluvial, o qual melhor preserva as evidências de um rearranjo em toda a bacia. Os principais fatores dos rearranjos de drenagem na área foram: o forte gradiente hipsométrico proporcionado pela Serra do Mar, a densa trama de foliações e fraturas presentes no embasamento geológico, movimentações tectônicas recentes e as oscilações paleoclimáticas do Quaternário tardio. Sob influência dessas forças, alguns tributários da drenagem litorânea teriam se aproveitado de sua vantagem erosiva frente aos rios de planalto, produzido uma marcha de erosão regressiva em direção ao interior, com interferências nos canais situados em níveis sucessivamente mais elevados. Com base nas propostas metodológicas de Small (1972), Bishop (1995), Zaprowski et al. (2002) e Oliveira (2003), buscou-se a identificação de elementos morfológicos e sedimentológicos sugestivos desses processos, por meio de: análise de Modelos Digitais do Terreno (MDE) por métodos geomorfométricos; observação de fotografias aéreas; trabalhos de campo para descrição e coleta de materiais sedimentológicos; análise granulométrica, morfoscópica e mineralógica de sedimentos fluviais; e datação de sedimentos fluviais por Luminescência Óptica Estimulada para se estimar a idade da captura do alto curso do Rio Capivari. Os dados apresentados corroboram a hipótese de que o alto curso desse rio sofreu uma captura há cerca de 8.000 anos, no máximo, e que diversos outros casos de rearranjos de drenagem, entre eles reversões de grandes sistemas fluviais, seriam responsáveis pelas anomalias de drenagem observadas no interior da bacia estudada. / The aim of this research was to understand the role of drainage rearrangements on the evolution of relief and drainage in the Capivari River basin, located on the reverse of Serra do Mar range, in the state of São Paulo, Brazil. It is assumed that these phenomena would be responsible for numerous drainage anomalies observed, such as: river inflections at right angles, anomalous drainage patterns, cols, knickpoints and river underfitting, considered as indicative for drainage rearrangements. Special emphasis will be given to the inflection of the Capivari River at the confluence with the Ribeirao Embura, a possible remnant of a stream capture, which best preserves the evidence of a rearrangement throughout the basin. The main factors of the drainage rearrangements in the area would be: the strong hypsometric gradient provided by Serra do Mar range, the set of foliations and fractures densely present in the geological basement, recent tectonic movements and climatic oscillations of the Quaternary. Under the influence of these forcings, some tributaries of the coastal drainage would have taken erosive advantage over the plateau upside rivers, producing a regressive erosion march towards the interior of the continent, leading to interferences in the river systems situated at successively higher levels. Based on the methodological proposals of Small (1972), Bishop (1995), Zaprowski et al. (2002) and Oliveira (2003), we seek the identification of morphological and sedimentological elements that are suggestive of these processes, by means of: Digital Elevation Models (DEM) analysis by geomorphometric methods; observation of aerial photographs; fieldwork for description and collection of sedimentological materials; granulometric, morphoscopic and mineralogical analysis of fluvial sediments; and dating of fluvial sediments by Optically Stimulated Luminescence to estimate the age of capture of the upper reaches of the Capivari River. The presented data corroborate the hypothesis that the high course of the Capivari river was captured at least 8,000 years ago and that several other cases of drainage rearrangements, including reversals of large river systems, would be responsible for the observed drainage anomalies.
29

Estabelecimento de padronização primária e de métodos relativos com o uso de técnicas luminescentes em dosimetria da radiação beta / Establishment of primary standardization and relative methods with the use of luminescent techniques in beta radiation dosimetry

Patrícia de Lara Antonio 19 February 2014 (has links)
Devido à inexistência de um laboratório de padronização primária na América Latina, para calibração e dosimetria de fontes de radiação beta, neste trabalho uma câmara de extrapolação Böhm foi caracterizada e estabelecida como um sistema padrão primário no Laboratório de Calibração de Instrumentos (LCI) do IPEN. Como objetivo principal deste trabalho, a câmara de extrapolação Böhm foi caracterizada com relação à sua resposta em feixes padrões secundários de radiação beta de fontes de 90Sr+90Y, com duas janelas de entrada diferentes: Mylar aluminizado e Hostaphan grafitado, e com dois métodos de determinação de taxa de dose absorvida, para verificação do seu desempenho com cada material. Embora se trate do instrumento mais adequado para a calibração de detectores e fontes de radiação beta, a câmara de extrapolação deve ser utilizada apenas em laboratórios de calibração e não em programas de controle de qualidade, pois ela tem 7 kg e é de alto custo. Assim, é importante ter sistemas considerados padrões de trabalho e métodos alternativos para substituir a câmara de extrapolação em medições realizadas em campo, como em hospitais ou clínicas. Por este motivo, foram caracterizadas três câmaras de ionização de placas paralelas, com o objetivo de se verificar a possibilidade de seu uso como sistemas padrões de trabalho em programas de controle de qualidade, e também foram estudados materiais dosimétricos diferentes, em campos de radiação beta de 90Sr+90Y, utilizando-se os fenômenos da termoluminescência (TL) e da luminescência opticamente estimulada (LOE), como métodos alternativos na calibração de fontes de radiação beta. Inclui-se aqui o desenvolvimento de um sistema postal dosimétrico para a calibração de aplicadores clínicos de 90Sr+90Y. Os resultados obtidos com a câmara de extrapolação Böhm permitiram o seu estabelecimento como sistema padrão primário na calibração de fontes de 90Sr+90Y, pois a câmara com as duas janelas de entrada diferentes permitiram a determinação de taxas de dose absorvida no ar e no tecido, à profundidade nula e a 0,07 mm. A caracterização das três câmaras de ionização de placas paralelas mostraram que elas podem ser usadas em programas de controle de qualidade de fontes de radiação beta, pois suas respostas se apresentaram adequadas para esta finalidade. Os materiais dosimétricos testados com relação às suas respostas TL e LOE também se mostraram adequados para uso em campos de radiação beta, pois suas respostas foram satisfatórias. O sistema dosimétrico, utilizando dosímetros TL, foi testado em hospitais e, posteriormente, foi enviado na forma postal a um laboratório, contendo detectores TL e LOE, e o resultado da calibração dos aplicadores clínicos foi adequado. / Due to the lack of a primary standard laboratory at the Latin America, for the calibration and dosimetry of beta radiation sources, it was decided to establish the Böhm extrapolation chamber at the Calibration Laboratory (LCI) at IPEN as a primary standard. As a main objective of this work, the Böhm extrapolation chamber was characterized in relation to its response in beta radiation secondary standard beams of 90Sr+90Y sources, using two different entrance windows: aluminized Mylar and graphited Hostaphan, and using two methods of determination of absorbed dose rates, to verify its performance in each material. Although it is the most adequate instrument for the calibration of beta radiation detectors and sources, the extrapolation chamber should only be used at calibration laboratories, and not in quality control programs, because it weights 7 kg, and it is expensive. Thus, it is important to have systems considered work standards and alternative methods to replace the extrapolation chamber in measurements performed outside laboratories, such as in hospitals and clinics. For this reason, three parallel plate ionization chambers were characterized, with the objective to verify the possibility of their use as work standard systems, and different dosimetric materials were also studied, in beta radiation fields, using the thermoluminescence (TL) and optically stimulated luminescence (OSL) phenomena, as alternative methods for the calibration of beta radiation sources. The development of a dosimetric postal system for the calibration of 90Sr+90Y clinical applicators was included in this objective. The results obtained using the Böhm extrapolation chamber allowed its establishment as a primary standard system at the calibration of 90Sr+90Y sources, because it was possible to determine the absorbed dose rates in air and in the tissue, at null depth and 0.07 mm using the chamber with the two different entrance windows. The characterization of the three parallel plate ionization chambers showed that they can be used in quality control programs of beta radiation sources, because their responses were adequate to this purpose. The dosimetric materials were tested in relation to their TL and OSL response, and their use showed also to be adequate in beta radiation fields. The dosimetric postal system, using TL dosimeters, was tested in hospitals, and afterwards, it was sent to a laboratory, by conventional mail, with TL and OSL detectors, and the results of the calibration of the clinical applicators was adequate.
30

Desenvolvimento e estudo de materiais termoluminescentes baseados em óxido de alumínio para aplicação em dosimetria / Development and study of thermoluminescent materials based on aluminum oxide for dosimetry application

Fukumori, David Tadashi 04 April 2012 (has links)
O óxido de alumínio foi um dos primeiros compostos investigados, com vista a detectar e medir a radiação por meio da termoluminescência (TL). Comumente referido como \"alumina\", o óxido de alumínio tem características interessantes para o desenvolvimento de materiais para a dosimetria. Seu número atômico efetivo é intermediário entre o do osso e do tecido mole do corpo. Pode ser transformado em material termoluminescente pela inserção de elementos químicos em sua estrutura cristalina. Além da TL, a alumina pode apresentar luminescência opticamente estimulada (OSL), fenômeno que também pode ser usado para determinar a dose de radiação. Neste estudo, dois métodos foram investigados para inserir íons metálicos na alumina. O primeiro método foi baseado na capacidade de adsorção da alumina e o segundo denominado método da coprecipitação foi baseado na formação simultânea de compostos insolúveis. As amostras obtidas por adsorção de íons Cu2+ e Mn2+ não mostraram resultados satisfatórios. No entanto, as pastilhas de óxido de alumínio impurificado com Tm3+ via coprecipitação mostraram sinais de TL e OSL. Foi verificado também que a alumina eletrofundida disponível comercialmente é um material que apresenta resposta TL e OSL. Este material que contém diversos íons metálicos em sua estrutura foi transformado em pastilhas por sinterização com vidro. As curvas da resposta TL em função da temperatura e da resposta TL e OSL em função da dose foram determinadas. Os resultados obtidos indicam que estudos mais aprofundados das pastilhas desenvolvidas podem melhorar suas características para que sejam aplicadas em dosimetria. / The aluminum oxide was one of the former compounds investigated with a view to detecting and measuring radiation by means of the thermoluminescence (TL). Commonly referred to as \"alumina\", aluminum oxide has interesting features for the development of materials for dosimetry. Its effective atomic number has an intermediate value between the bone and soft tissue of the body. It can be transformed into TL material by the insertion of chemical elements in its crystal structure. In addition to the TL, the alumina can provide optically stimulated luminescence (OSL) which can also be used to determine the radiation dose. In this study, two methods were investigated in order to insert metal ions in alumina. The first method was based on the adsorption capacity of alumina and the second named coprecipitation method was based on the simultaneous formation of insoluble compounds. The samples obtained by adsorption of Cu2+ and Mn2+ ions did not show satisfactory results. However, the aluminum oxide impurified with Tm3+ by coprecipitation showed TL and OSL signals. It was also found that the commercially available electrofused alumina is a material that exhibits TL and OSL. This material that contains various metal ions in its structure was made into pellets by sintering with glass. The TL response curves as a function of temperature and the TL and OSL responses as a function of the dose were determined. The obtained results indicate that further studies of the developed pellets can improve the characteristics in order to be applied in dosimetry.

Page generated in 0.131 seconds