• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 101
  • 3
  • Tagged with
  • 104
  • 104
  • 29
  • 27
  • 25
  • 21
  • 18
  • 18
  • 18
  • 16
  • 15
  • 15
  • 15
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Influência da volumetria e das condições de entorno da edificação no manchamento e infiltração de água em fachadas por ação de chuva dirigida / Volumetry and building surrounding conditions influence on staining and water infiltration in facades by the action of wind-driven rain

Poyastro, Patricia Carone January 2011 (has links)
Os problemas de manchamento e infiltração de água nas fachadas das edificações, por ação de chuva dirigida, são cada vez mais correntes nos grandes centros urbanos brasileiros. Estas manifestações patológicas ocasionam não só problemas do ponto de vista estético, mas também técnico. Um dos fatores que mais contribuíram para o aparecimento destes problemas foram as características construtivas adotadas pela arquitetura moderna, que deixou de utilizar muitos detalhes arquitetônicos que preveniam o escorrimento da chuva e dos poluentes atmosféricos pelas fachadas. Além disso, os novos materiais e sistemas construtivos introduzidos nas últimas décadas trouxeram também mais problemas de umidade e infiltração de água. O aprofundamento neste tema é importante e necessário, uma vez que faltam estudos práticos que testem e especifiquem melhores volumetrias e entornos visando minimizar estes fenômenos. Sendo assim, este trabalho teve como objetivo avaliar a influência da volumetria e das condições de entorno da edificação no manchamento de superfícies e infiltração de água em fachadas por ação de chuva dirigida. Foram ensaiados em túnel de vento, três modelos reduzidos de edificações com diferentes volumetrias e com três alturas diferentes de edificações de entorno. Os modelos reduzidos foram ensaiados primeiramente somente com vento, onde se obteve os coeficientes de pressão do vento em diferentes pontos das fachadas. Após, foram ensaiados com a inserção de água no túnel de vento, simulando a ação da chuva dirigida nas edificações. Nesta segunda etapa, a análise foi visual, através de registros em papéis sensíveis à água colados nos modelos. Além disso, alguns ensaios complementares foram realizados com fins exploratórios. Com base nos resultados encontrados pode-se afirmar que a ação do vento e da chuva atuando simultaneamente é muito diferente da ação dos mesmos atuando isoladamente nas edificações. Com a realização dos ensaios se verificou que a forma da edificação praticamente não influenciou no padrão de molhamento quando a chuva dirigida incide a 90° na fachada e que os entornos influenciaram negativamente no molhamento das fachadas, com exceção do entorno com dobro da altura. Este trabalho pôde contribuir para um melhor entendimento da ação da chuva dirigida visando a redução de manifestações patológicas das edificações. / The problems of staining and water infiltration through building facades, by the action of winddriven rain, are becoming more common in the Brazilian cities. These pathologies cause esthetic and technical problems. The modern architecture contributed to the emergence of these problems because it stopped using many architectural details that used to prevent the rain and atmospheric pollutants runoff by the facades. Moreover, new materials and construction systems introduced in recent decades have also brought more problems with moisture and water infiltration. Studies of this subject are important and necessary, since they lack practical studies to test and specify the best volumetry and building surroundings, designed to minimize these phenomena. This work objective was evaluate the influence of volume and the building surrounding conditions on staining and water infiltration in facades by the action of wind-driven rain. Three reduced models of buildings with different volumetry and with three different heights of buildings surrounding were tested in wind tunnel. The reduced models were first tested only with the wind when were measured wind pressures coefficients at different points of the facades. After, they were tested with the inclusion of water in the wind tunnel, simulating the effects of wind-driven rain on buildings. In this second stage, the analysis was visual, through the winddriven rain recorded in water-sensitive papers fixed on the models facades. Moreover, some complementary tests were done for exploratory purposes. Based on the results, we can say that wind and rain acting simultaneously are very different from they acting alone in the buildings. It was found with the tests that the volumetry of the building did not appreciably affect the pattern of wetting when the rain hits it directed in 90° and t hat the buildings surrounding negatively influenced on the wetting fronts, except the buildings surrounding with double height. This work could contribute to a better understanding of the driving rain phenomenon intending to reduce building pathological manifestations.
62

Estudo da influência das propriedades relacionadas à superfície e à matriz na resistência à abrasão de concretos para pisos / Study on the influence of properties related to the surface and matrix in the abrasion resistance of concrete floors

Silva, Cristina Vitorino da January 2015 (has links)
O desgaste superficial por abrasão é uma manifestação patológica que decorre do atrito entre partículas secas e a superfície do material, causando uma perda progressiva das camadas mais externas da estrutura. Entender esse mecanismo de deterioração e ainda os parâmetros que influenciam a sua ocorrência são preocupações válidas, visto que ele compromete a durabilidade e a funcionalidade de estruturas, tais como pisos de concreto. Além disso, a correção desta manifestação patológica exige gastos elevados com reparo ou substituição do concreto e, dessa maneira, a necessidade de maiores estudos buscando ações mais efetivas na prática é justificada. Neste particular, estudou-se a influência das propriedades relacionadas à matriz e à superfície na resistência à abrasão dos compósitos. Para tanto, alguns fatores que influenciam na qualidade dos concretos empregados em pisos, como o tipo de cimento (CP IV; CP V-ARI), a relação água/aglomerante (0,40; 0,60), o teor de substituição de sílica ativa (0%; 10%) e o tipo de cura (submersa; caixa aquecida) foram avaliados. Os ensaios adotados para estudar a influência das propriedades de massa no mecanismo de degaste foram os de resistência à compressão uniaxial, resistência à tração na flexão e exsudação. Já os ensaios para verificar a influência das propriedades de superfície na magnitude desse mecanismo foram os de dureza superficial, resistência à abrasão, porosimetria por intrusão de mercúrio, microdureza por indentação, análises em microscópio estereoscópico e a digitalização tridimensional à laser. Os resultados encontrados mostraram uma influência estatística significativa do tipo de cimento sobre todas as propriedades avaliadas, sendo que o cimento de alta resistência inicial apresentou melhor desempenho em comparação ao cimento pozolânico, considerando uma mesma idade de análise (63 dias). Além disso, verificou-se uma influência estatística significativa da relação a/agl no comportamento dos concretos, onde a relação a/agl 0,6 aumentou os índices de desgaste das amostras em relação as de referência (a/agl 0,4), conforme esperado. Quanto ao tipo de cura, os compósitos curados de forma submersa apresentaram os melhores resultados frente ao desgaste superficial comparando-se àqueles mantidos na cura em caixa aquecida. Finalmente, analisando o teor de substituição de sílica ativa, observou-se que a substituição de 10 % sobre a massa de cimento proporcionou acréscimos estatisticamente significativos na resistência à abrasão das amostras com menor relação a/agl; somando-se a isto, a presença da sílica minimizou o efeito da cura em caixa aquecida na camada superficial das amostras de concreto submetidas ao desgaste. Concluindo, a resistência à abrasão dos concretos mostrou ter uma importante relação não somente com as suas propriedades de massa, mas também com a qualidade da sua camada superficial, uma vez que apresentou forte correlação com as características de superfície avaliadas, como a dureza superficial, a microdureza e a porosimetria ao mercúrio. Além disso, salienta-se que o ensaio de dureza superficial por esclerometria poderia ser adotado como parâmetro para determinação direta da resistência ao desgaste e sugere-se que a exsudação dos pisos de concreto venha a ser o fator principal no controle da qualidade da camada superficial da placa de concreto. / Surface abrasion wear is a pathological manifestation triggered by friction between dried particles and the surface of the material, provoking a progressive loss of the outermost layers. The comprehension of this mechanism of deterioration and also the parameters that influence its occurrence are valid concerns, since it compromises the durability and functionality of structures such as concrete floors. In addition, repair this pathological manifestation or replace the damage concrete require high expenditure. Thus, the necessity of further studies seeking for practical effective actions is justified. In this particular, the aim of this work was to study the influence of properties related to the matrix and the surface of composites on abrasion resistance. For this purpose, some factors that influence the quality of the concrete used in floors, including the cement type (CP IV; CP V-ARI), the water / binder ratio (0.40, 0.60), the replacement content of silica fume (0%, 10%) and the conditions of cure (submerged; heat box) were evaluated. The assays employed in order to study the influence of mass properties on the wear mechanism were the compressive strength, flexural tensile strength and bleeding. As regards to the influence of surface properties on the magnitude of this mechanism, it was verified by testing the surface hardness, abrasion resistance, porosimetry by mercury intrusion, microhardness by indentation, analysis in stereoscopic microscope and three-dimensional laser scanning. The obtained data demonstrated a statistically significant influence of cement type on all assessed properties, with the high early strength cement presenting a better performance as compared to pozzolan cement, considering a similar age of analysis (63 days). Furthermore, there was a statistically significant influence of water / binder ratio on concrete behavior, where the water / binder ratio of 0.6 increased the wear rates of the samples in comparison to the reference (water / binder 0.4), as expected. Regarding to the conditions of cure, the submerged composites showed better results against surface wear as compared to those kept in the heat box. Finally, it was observed that the replacement content of silica fume of 10% on the cement mass provided statistically significant increases in abrasion resistance of samples with lower water / binder ratio. In addition, the presence of silica minimized the effects of curing in a heat box on the surface layer of concrete samples that were submitted to wear. In conclusion, the abrasion resistance of concretes demonstrated an important relationship not only with the mass properties of these structures but also with the quality of their surface layer, since a strong correlation with the evaluated surface features was observed, including surface hardness, microhardness and porosimetry by mercury intrusion. Moreover, it is emphasized that the surface hardness assay by rebound hammer may be used as a parameter for direct determination of wear resistance and it is suggested that bleeding of concrete floors might be the main factor for controlling the surface layer quality of the concrete slab.
63

Análise do desempenho de placas cimentícias através da adição de fibras e telas, visando a redução de deformações térmicas e patologias

Speck, Jaison Araujo January 2014 (has links)
As constantes e crescentes transformações ocorridas nos diversos segmentos da economia mundial levam à busca incessante de conhecimento, bem como à busca do aprimoramento em atividades relacionadas com as diversas funções do mercado de trabalho, sempre com o objetivo de se alcançar lucros, desempenho adequado e promovendo o uso racional de materiais e insumos, e consequentemente garantindo o desenvolvimento sustentável. Com o grande crescimento no setor de construção civil, surge uma oportunidade de introdução e comercialização de novos produtos como placas cimentícias, com âmbito de decoração e estética no seguimento de revestimento para pisos e fachadas. Neste trabalho será abordada uma falha quanto ao aspecto funcional do produto, que é o descolamento/destacamento das placas cimentícias assentadas e fissuras nas placas cimentícias aderidas. Várias podem ser as fontes dessa manifestação patológica, entre elas: materiais e métodos de assentamento inadequados (local, juntas, argamassa, entre outros), inadequações das características funcionais (dilatação térmica, EPU, entre outros). Foram adicionadas fibras de vidro, fibras de polipropileno, telas de fibra de vidro e telas metálicas, com finalidade de melhorar as propriedades funcionais das placas. Como resultado final, tanto as telas metálicas como as telas de fibra de vidro finas apresentaram melhor desempenho quanto à resistência mecânica, dilatação térmica e expansão térmica, evitando as patologias apresentadas e ao mesmo tempo melhorando o desempenho das placas cimentícias. / The constant and growing changes occurring in the various segments of the world economy lead to the ceaseless pursuit of knowledge and the quest for improvement in activities related to the various functions of the job market. Always with the objective of achieving profits, adequate performance and promoting the rational use of materials and supplies, and therefore ensuring sustainable development. With the growth in the construction sector, an opportunity arises as the introduction of new products and marketing of cement slabs, for decoration and aesthetics for floors and facades coating. This work will be discussed a failure to functional aspect of the product, which is the detachment / secondment of cement slabs settled and cracks in cement slabs attached. Several can be the sources of this pathology manifastation, including: inadequate materials and methods of settlement (Local, joints, mortar, etc.), inadequacies of the functional characteristics (thermal expansion, UPC, etc.). Glass fibers, polypropylene fibers, glass screens and wires were added, with the purpose of improving the properties functional of the plates. As a final result both mesh screens as thin fiberglass presented better performance as the mechanical strength, thermal expansion and expansion, preventing pathologies and at the same time improving the performance of cement boards.
64

Corrosão por cloretos em estruturas de concreto armado : uma meta-análise / Corrosion by chlorides in reinforced concrete structures: a meta-analysis

Torres, Ariela da Silva January 2011 (has links)
O concreto é o segundo material mais consumido no mundo, perdendo somente para água, justificando a importância de estudos que envolvam seu comportamento frente à durabilidade, e que objetivam a obtenção de estruturas com longas vidas úteis. Dentre as diversas manifestações patológicas que ocorrem nas estruturas de concreto armado, a corrosão das armaduras tem uma grande incidência, como já comprovado por diversos autores. A corrosão das armaduras ocorre pela ação de agentes agressivos sendo que os dois principais são a carbonatação e a penetração de cloretos. Em função da grande costa marítima do Brasil, a ação de íons cloretos é a mais significativa, deteriorando estruturas e levando a necessidade de manutenções periódicas. Porém, sabe-se do alto custo para realização destas manutenções. Em função da preocupação com a manutenção e gastos das estruturas de concreto armado, este estudo objetivou realizar uma validação dos ensaios de corrosão por cloretos em estruturas de concreto armado a partir de meta-análise dos dados de técnicas eletroquímicas utilizadas nos trabalhos de teses e dissertações desenvolvidos no Brasil. Pretende-se desta maneira realizar um mapeamento das pesquisas na área de corrosão em armaduras de concreto armado realizadas no Brasil e direcionar os futuros estudos. Pretende-se também realizar uma análise conjunta de todos estes trabalhos para verificar a quantidade e qualidade dos mesmos sob uma visão do conjunto nacional. Registrou-se a falta de pesquisas na região Norte do país e a centralização das mesmas nas regiões Sudeste e Sul. Com o uso de técnicas estatísticas conclui-se a falta de diversas combinações de variáveis (relação água/cimento, tipo de cimento, método de indução de cloretos, adição de materiais, entre outros) para criação de um modelo brasileiro confiável. / Concrete is the second most consumed material in the world, second only to water, explaining the importance of studies involving behavior concerning durability, and aimed to obtain structures with long lifetimes. Among the various pathologics that occur in reinforced concrete structures, corrosion of the reinforcement has a major impact, as proven by several authors. The reinforcement corrosion occurs by the action of aggressive agents and the two main ones are carbonation and chloride penetration. Due to the great sea coast of Brazil, the action of chloride ions is the most significant and deteriorating structures leading to the need for periodic maintenance, but it is known the high cost of implementing these maintenances. Because of concerns with the maintenance and expense of concrete structures, this study aimed to perform a validation of the corrosion by chlorides in reinforced concrete structures from the meta-analysis of data from electrochemical techniques used in the work of theses and dissertations developed in Brazil. The aim is thus to map the research on corrosion in reinforced concrete made in Brazil and direct future studies. Also perform a joint analysis of all these works to verify the quantity and quality of these in a vision of the National Assembly. We observed the lack of research in the northern region of the country and centralizing them in the Southeast and South By using statistical techniques concludes the lack of various combinations of variables (water / cement ratio, cement type, method induction of chloride, addition of materials, among others) to create a Brazilian model reliable.
65

Avaliação da sensibilidade do CAIM - corrosão acelerada por imersão modificada - frente ao processo de corrosão em armaduras de concreto armado

Torres, Ariela da Silva January 2006 (has links)
A construção civil vem se deparando com uma dualidade que envolve avanços dos métodos de cálculo e tecnologia dos materiais contraposto ao incremento das patologias das construções. Inúmeros levantamentos estatísticos, realizados nos últimos anos, vem demonstrando a grande incidência e repercussão dos processos patológicos atuantes sobre as estruturas de concreto. Vários estudos comprovam que a corrosão de armaduras no concreto é de grande incidência nas construções e, na maioria dos casos, aquele que gera os maiores problemas, tanto em termos de custo como de segurança. Isto explica porque técnicas de medição de resistência à corrosão vêm sendo intensamente estudadas. Todavia, dada a complexidade do assunto e a falta de normalização específica, observa-se a existência de uma grande diversidade de métodos de ensaio, aliada à ausência de uma padronização dos tipos e condições de ensaio. A maioria dos pesquisadores adapta ensaios anteriormente realizados, sem realizar estudos específicos sobre a eficiência e reprodutibilidade dos mesmos. O presente trabalho descreve um estudo realizado com o intuito de avaliar qual os efeitos das variações das condições de ensaio, como tempo de exposição e diferença de potencial induzida, no comportamento de corpos-de-prova de diversas relações água/cimento testados pela metodologia CAIM, um tipo de ensaio acelerado comparativo de corrosão por imersão em solução salina, que já foi empregado em várias pesquisas no LEME. O objetivo é entender como o ensaio reage a variações de método, verificando sua sensibilidade a estas e definindo quais as condições padrão mais adequadas. / The construction community is facing a dualistic reality, where advances in design methods and materials technology are opposed by the increase in pathological problems registered in our structures. Several recent surveys have pointed out that several and important deterioration processes occur in concrete structures. Many studies indicate that reinforcement corrosion is one of the most prevalent and costly between these. That explains why there are so much interest in studying methods to evaluate the corrosion resistance of construction materials. However, given the complexity of the theme and the lack of standardization, a great diversity of methods have evolved, without a proper definition and parameterization of testing conditions. A great number of researches simply adapt methods used by others, not paying enough attention to the evaluation of the efficiency and reproducibility of the test method. This prevents the comparison of results and creates obstacles to sharing data and articulate research efforts. The present work describes a study aimed at evaluating the influence of variations in test conditions, such as exposure time and induce voltage, in the performance of mortar samples with different w/c relations subjected to the CAIM test. This comparative accelerated method, in which mortar samples are immersed on a saline solution and connected to a constant voltage source, has already been used in several studies at LEME. The study analyses how the method respond to variations in test conditions and will help establish the more efficient standard conditions for the test considering the whole range of concrete strengths.
66

Marquises de concreto armado da cidade de Viçosa-MG: manifestações patológicas, inspeção e avaliação de grau de deterioração / Marquees of reinforced concrete of the city Viçosa-MG: pathological manifestations, inspection and assessment of degree of deterioration

Gonçalves, Márcio de Oliveira 21 February 2011 (has links)
Made available in DSpace on 2015-03-26T13:28:00Z (GMT). No. of bitstreams: 1 texto completo.pdf: 9041921 bytes, checksum: c59da2f60e5152aaeffd89fd602328f2 (MD5) Previous issue date: 2011-02-21 / Marquees can be defined as elements that are part of the building and they are projected on public areas, with projections in the plan of the facades. Structural accidents with these elements are more and more frequent and they show the risk that a lot of times these structures can bring. Many are the common pathological manifestations in marquees, with several causes, as project mistakes, execution and use. The city of Viçosa - MG possesses several marquees in central area, some with pathological manifestations that need studies. The several examples of accidents, some recent ones, and the fact that still didn't exist studies of the marquees of the city, where at least a sinister one happened, they show the need to develop a work with these elements. Like this being, with the objective of evaluating the structural acting of marquees of armed concrete in the city of Viçosa 59 marquees were registered, of which 8 went by technical inspection. In these inspections they were identified the main pathological manifestations and maintenance conditions. With the use of methods a little destructive geometric risings were accomplished, identification of depth carbonation with alcoholic solution of phenolphthalein, corrosion identification in reinforcing steel rods and verification of general conditions of the concrete. Besides, it was used in the evaluation the methodology GDE/UnB for quantification of the risk degree. The obtained results evidence the importance of inspections in marquees of reinforced concrete and they show that some need immediate interventions to avoid larger risks. It is possible to notice although some marquees don't go by maintenance and they possess deteriorations, some with possibility of committing the element. It was possible to end although the methodology GDE/UnB can be applied for quantification of risk degree in marquees, except in marquees with insufficient reinforcing steel rods or without reinforcing steel rods, or in the cases that the reinforcing steel rods where are positioned incorrectly. Then some are proposed measured for construction and maintenance of marquees, to avoid that these elements deteriorate and they can suffer collapse. / Marquises podem ser definidas como elementos que fazem parte do edifício e se projetam sobre logradouros públicos, com balanços engastados no plano das fachadas. Acidentes estruturais com estes elementos são cada vez mais frequentes e mostram o risco que muitas vezes estas estruturas podem trazer. Muitas são as manifestações patológicas comuns em marquises, com causas diversas, como erros de projeto, execução e utilização. A cidade de Viçosa-MG possui várias marquises em sua região central, algumas com manifestações patológicas que necessitam de estudos. Os vários exemplos de acidentes, alguns recentes, e o fato de que não existiam ainda estudos das marquises da cidade, onde pelo menos um sinistro ocorreu, mostram a necessidade de desenvolver um trabalho com estes elementos. Assim sendo, com o objetivo de avaliar o desempenho estrutural de marquises de concreto armado na cidade de Viçosa foram cadastradas 59 marquises, das quais 8 passaram por inspeção técnica. Nestas inspeções foram identificadas as principais manifestações patológicas e condições de manutenção. Com o uso de métodos pouco destrutivos, foram realizados levantamentos geométricos, identificação de profundidade de carbonatação com solução alcoólica de fenolftaleína, identificação de corrosão em armaduras e verificação de condições gerais do concreto. Além disto, foi utilizada na avaliação a metodologia GDE/UnB para quantificação do grau de risco. Os resultados obtidos evidenciam a importância de inspeções em marquises de concreto armado e mostram que algumas necessitam de intervenções imediatas para evitar maiores riscos. É possível perceber ainda que algumas marquises não passam por manutenção e possuem deteriorações, algumas com possibilidade de comprometer o elemento. Foi possível concluir ainda que a metodologia GDE/UnB pode ser aplicada para quantificação de grau de risco em marquises, exceto em marquises com armadura insuficiente ou sem armaduras, ou ainda nos casos onde estas estejam posicionadas incorretamente. São propostas então algumas medidas para construção e manutenção de marquises, para evitar que estes elementos se deteriorem e possam sofrer colapso.
67

Análise do desempenho de placas cimentícias através da adição de fibras e telas, visando a redução de deformações térmicas e patologias

Speck, Jaison Araujo January 2014 (has links)
As constantes e crescentes transformações ocorridas nos diversos segmentos da economia mundial levam à busca incessante de conhecimento, bem como à busca do aprimoramento em atividades relacionadas com as diversas funções do mercado de trabalho, sempre com o objetivo de se alcançar lucros, desempenho adequado e promovendo o uso racional de materiais e insumos, e consequentemente garantindo o desenvolvimento sustentável. Com o grande crescimento no setor de construção civil, surge uma oportunidade de introdução e comercialização de novos produtos como placas cimentícias, com âmbito de decoração e estética no seguimento de revestimento para pisos e fachadas. Neste trabalho será abordada uma falha quanto ao aspecto funcional do produto, que é o descolamento/destacamento das placas cimentícias assentadas e fissuras nas placas cimentícias aderidas. Várias podem ser as fontes dessa manifestação patológica, entre elas: materiais e métodos de assentamento inadequados (local, juntas, argamassa, entre outros), inadequações das características funcionais (dilatação térmica, EPU, entre outros). Foram adicionadas fibras de vidro, fibras de polipropileno, telas de fibra de vidro e telas metálicas, com finalidade de melhorar as propriedades funcionais das placas. Como resultado final, tanto as telas metálicas como as telas de fibra de vidro finas apresentaram melhor desempenho quanto à resistência mecânica, dilatação térmica e expansão térmica, evitando as patologias apresentadas e ao mesmo tempo melhorando o desempenho das placas cimentícias. / The constant and growing changes occurring in the various segments of the world economy lead to the ceaseless pursuit of knowledge and the quest for improvement in activities related to the various functions of the job market. Always with the objective of achieving profits, adequate performance and promoting the rational use of materials and supplies, and therefore ensuring sustainable development. With the growth in the construction sector, an opportunity arises as the introduction of new products and marketing of cement slabs, for decoration and aesthetics for floors and facades coating. This work will be discussed a failure to functional aspect of the product, which is the detachment / secondment of cement slabs settled and cracks in cement slabs attached. Several can be the sources of this pathology manifastation, including: inadequate materials and methods of settlement (Local, joints, mortar, etc.), inadequacies of the functional characteristics (thermal expansion, UPC, etc.). Glass fibers, polypropylene fibers, glass screens and wires were added, with the purpose of improving the properties functional of the plates. As a final result both mesh screens as thin fiberglass presented better performance as the mechanical strength, thermal expansion and expansion, preventing pathologies and at the same time improving the performance of cement boards.
68

Estudo da influência das propriedades relacionadas à superfície e à matriz na resistência à abrasão de concretos para pisos / Study on the influence of properties related to the surface and matrix in the abrasion resistance of concrete floors

Silva, Cristina Vitorino da January 2015 (has links)
O desgaste superficial por abrasão é uma manifestação patológica que decorre do atrito entre partículas secas e a superfície do material, causando uma perda progressiva das camadas mais externas da estrutura. Entender esse mecanismo de deterioração e ainda os parâmetros que influenciam a sua ocorrência são preocupações válidas, visto que ele compromete a durabilidade e a funcionalidade de estruturas, tais como pisos de concreto. Além disso, a correção desta manifestação patológica exige gastos elevados com reparo ou substituição do concreto e, dessa maneira, a necessidade de maiores estudos buscando ações mais efetivas na prática é justificada. Neste particular, estudou-se a influência das propriedades relacionadas à matriz e à superfície na resistência à abrasão dos compósitos. Para tanto, alguns fatores que influenciam na qualidade dos concretos empregados em pisos, como o tipo de cimento (CP IV; CP V-ARI), a relação água/aglomerante (0,40; 0,60), o teor de substituição de sílica ativa (0%; 10%) e o tipo de cura (submersa; caixa aquecida) foram avaliados. Os ensaios adotados para estudar a influência das propriedades de massa no mecanismo de degaste foram os de resistência à compressão uniaxial, resistência à tração na flexão e exsudação. Já os ensaios para verificar a influência das propriedades de superfície na magnitude desse mecanismo foram os de dureza superficial, resistência à abrasão, porosimetria por intrusão de mercúrio, microdureza por indentação, análises em microscópio estereoscópico e a digitalização tridimensional à laser. Os resultados encontrados mostraram uma influência estatística significativa do tipo de cimento sobre todas as propriedades avaliadas, sendo que o cimento de alta resistência inicial apresentou melhor desempenho em comparação ao cimento pozolânico, considerando uma mesma idade de análise (63 dias). Além disso, verificou-se uma influência estatística significativa da relação a/agl no comportamento dos concretos, onde a relação a/agl 0,6 aumentou os índices de desgaste das amostras em relação as de referência (a/agl 0,4), conforme esperado. Quanto ao tipo de cura, os compósitos curados de forma submersa apresentaram os melhores resultados frente ao desgaste superficial comparando-se àqueles mantidos na cura em caixa aquecida. Finalmente, analisando o teor de substituição de sílica ativa, observou-se que a substituição de 10 % sobre a massa de cimento proporcionou acréscimos estatisticamente significativos na resistência à abrasão das amostras com menor relação a/agl; somando-se a isto, a presença da sílica minimizou o efeito da cura em caixa aquecida na camada superficial das amostras de concreto submetidas ao desgaste. Concluindo, a resistência à abrasão dos concretos mostrou ter uma importante relação não somente com as suas propriedades de massa, mas também com a qualidade da sua camada superficial, uma vez que apresentou forte correlação com as características de superfície avaliadas, como a dureza superficial, a microdureza e a porosimetria ao mercúrio. Além disso, salienta-se que o ensaio de dureza superficial por esclerometria poderia ser adotado como parâmetro para determinação direta da resistência ao desgaste e sugere-se que a exsudação dos pisos de concreto venha a ser o fator principal no controle da qualidade da camada superficial da placa de concreto. / Surface abrasion wear is a pathological manifestation triggered by friction between dried particles and the surface of the material, provoking a progressive loss of the outermost layers. The comprehension of this mechanism of deterioration and also the parameters that influence its occurrence are valid concerns, since it compromises the durability and functionality of structures such as concrete floors. In addition, repair this pathological manifestation or replace the damage concrete require high expenditure. Thus, the necessity of further studies seeking for practical effective actions is justified. In this particular, the aim of this work was to study the influence of properties related to the matrix and the surface of composites on abrasion resistance. For this purpose, some factors that influence the quality of the concrete used in floors, including the cement type (CP IV; CP V-ARI), the water / binder ratio (0.40, 0.60), the replacement content of silica fume (0%, 10%) and the conditions of cure (submerged; heat box) were evaluated. The assays employed in order to study the influence of mass properties on the wear mechanism were the compressive strength, flexural tensile strength and bleeding. As regards to the influence of surface properties on the magnitude of this mechanism, it was verified by testing the surface hardness, abrasion resistance, porosimetry by mercury intrusion, microhardness by indentation, analysis in stereoscopic microscope and three-dimensional laser scanning. The obtained data demonstrated a statistically significant influence of cement type on all assessed properties, with the high early strength cement presenting a better performance as compared to pozzolan cement, considering a similar age of analysis (63 days). Furthermore, there was a statistically significant influence of water / binder ratio on concrete behavior, where the water / binder ratio of 0.6 increased the wear rates of the samples in comparison to the reference (water / binder 0.4), as expected. Regarding to the conditions of cure, the submerged composites showed better results against surface wear as compared to those kept in the heat box. Finally, it was observed that the replacement content of silica fume of 10% on the cement mass provided statistically significant increases in abrasion resistance of samples with lower water / binder ratio. In addition, the presence of silica minimized the effects of curing in a heat box on the surface layer of concrete samples that were submitted to wear. In conclusion, the abrasion resistance of concretes demonstrated an important relationship not only with the mass properties of these structures but also with the quality of their surface layer, since a strong correlation with the evaluated surface features was observed, including surface hardness, microhardness and porosimetry by mercury intrusion. Moreover, it is emphasized that the surface hardness assay by rebound hammer may be used as a parameter for direct determination of wear resistance and it is suggested that bleeding of concrete floors might be the main factor for controlling the surface layer quality of the concrete slab.
69

Influência da volumetria e das condições de entorno da edificação no manchamento e infiltração de água em fachadas por ação de chuva dirigida / Volumetry and building surrounding conditions influence on staining and water infiltration in facades by the action of wind-driven rain

Poyastro, Patricia Carone January 2011 (has links)
Os problemas de manchamento e infiltração de água nas fachadas das edificações, por ação de chuva dirigida, são cada vez mais correntes nos grandes centros urbanos brasileiros. Estas manifestações patológicas ocasionam não só problemas do ponto de vista estético, mas também técnico. Um dos fatores que mais contribuíram para o aparecimento destes problemas foram as características construtivas adotadas pela arquitetura moderna, que deixou de utilizar muitos detalhes arquitetônicos que preveniam o escorrimento da chuva e dos poluentes atmosféricos pelas fachadas. Além disso, os novos materiais e sistemas construtivos introduzidos nas últimas décadas trouxeram também mais problemas de umidade e infiltração de água. O aprofundamento neste tema é importante e necessário, uma vez que faltam estudos práticos que testem e especifiquem melhores volumetrias e entornos visando minimizar estes fenômenos. Sendo assim, este trabalho teve como objetivo avaliar a influência da volumetria e das condições de entorno da edificação no manchamento de superfícies e infiltração de água em fachadas por ação de chuva dirigida. Foram ensaiados em túnel de vento, três modelos reduzidos de edificações com diferentes volumetrias e com três alturas diferentes de edificações de entorno. Os modelos reduzidos foram ensaiados primeiramente somente com vento, onde se obteve os coeficientes de pressão do vento em diferentes pontos das fachadas. Após, foram ensaiados com a inserção de água no túnel de vento, simulando a ação da chuva dirigida nas edificações. Nesta segunda etapa, a análise foi visual, através de registros em papéis sensíveis à água colados nos modelos. Além disso, alguns ensaios complementares foram realizados com fins exploratórios. Com base nos resultados encontrados pode-se afirmar que a ação do vento e da chuva atuando simultaneamente é muito diferente da ação dos mesmos atuando isoladamente nas edificações. Com a realização dos ensaios se verificou que a forma da edificação praticamente não influenciou no padrão de molhamento quando a chuva dirigida incide a 90° na fachada e que os entornos influenciaram negativamente no molhamento das fachadas, com exceção do entorno com dobro da altura. Este trabalho pôde contribuir para um melhor entendimento da ação da chuva dirigida visando a redução de manifestações patológicas das edificações. / The problems of staining and water infiltration through building facades, by the action of winddriven rain, are becoming more common in the Brazilian cities. These pathologies cause esthetic and technical problems. The modern architecture contributed to the emergence of these problems because it stopped using many architectural details that used to prevent the rain and atmospheric pollutants runoff by the facades. Moreover, new materials and construction systems introduced in recent decades have also brought more problems with moisture and water infiltration. Studies of this subject are important and necessary, since they lack practical studies to test and specify the best volumetry and building surroundings, designed to minimize these phenomena. This work objective was evaluate the influence of volume and the building surrounding conditions on staining and water infiltration in facades by the action of wind-driven rain. Three reduced models of buildings with different volumetry and with three different heights of buildings surrounding were tested in wind tunnel. The reduced models were first tested only with the wind when were measured wind pressures coefficients at different points of the facades. After, they were tested with the inclusion of water in the wind tunnel, simulating the effects of wind-driven rain on buildings. In this second stage, the analysis was visual, through the winddriven rain recorded in water-sensitive papers fixed on the models facades. Moreover, some complementary tests were done for exploratory purposes. Based on the results, we can say that wind and rain acting simultaneously are very different from they acting alone in the buildings. It was found with the tests that the volumetry of the building did not appreciably affect the pattern of wetting when the rain hits it directed in 90° and t hat the buildings surrounding negatively influenced on the wetting fronts, except the buildings surrounding with double height. This work could contribute to a better understanding of the driving rain phenomenon intending to reduce building pathological manifestations.
70

Corrosão por cloretos em estruturas de concreto armado : uma meta-análise / Corrosion by chlorides in reinforced concrete structures: a meta-analysis

Torres, Ariela da Silva January 2011 (has links)
O concreto é o segundo material mais consumido no mundo, perdendo somente para água, justificando a importância de estudos que envolvam seu comportamento frente à durabilidade, e que objetivam a obtenção de estruturas com longas vidas úteis. Dentre as diversas manifestações patológicas que ocorrem nas estruturas de concreto armado, a corrosão das armaduras tem uma grande incidência, como já comprovado por diversos autores. A corrosão das armaduras ocorre pela ação de agentes agressivos sendo que os dois principais são a carbonatação e a penetração de cloretos. Em função da grande costa marítima do Brasil, a ação de íons cloretos é a mais significativa, deteriorando estruturas e levando a necessidade de manutenções periódicas. Porém, sabe-se do alto custo para realização destas manutenções. Em função da preocupação com a manutenção e gastos das estruturas de concreto armado, este estudo objetivou realizar uma validação dos ensaios de corrosão por cloretos em estruturas de concreto armado a partir de meta-análise dos dados de técnicas eletroquímicas utilizadas nos trabalhos de teses e dissertações desenvolvidos no Brasil. Pretende-se desta maneira realizar um mapeamento das pesquisas na área de corrosão em armaduras de concreto armado realizadas no Brasil e direcionar os futuros estudos. Pretende-se também realizar uma análise conjunta de todos estes trabalhos para verificar a quantidade e qualidade dos mesmos sob uma visão do conjunto nacional. Registrou-se a falta de pesquisas na região Norte do país e a centralização das mesmas nas regiões Sudeste e Sul. Com o uso de técnicas estatísticas conclui-se a falta de diversas combinações de variáveis (relação água/cimento, tipo de cimento, método de indução de cloretos, adição de materiais, entre outros) para criação de um modelo brasileiro confiável. / Concrete is the second most consumed material in the world, second only to water, explaining the importance of studies involving behavior concerning durability, and aimed to obtain structures with long lifetimes. Among the various pathologics that occur in reinforced concrete structures, corrosion of the reinforcement has a major impact, as proven by several authors. The reinforcement corrosion occurs by the action of aggressive agents and the two main ones are carbonation and chloride penetration. Due to the great sea coast of Brazil, the action of chloride ions is the most significant and deteriorating structures leading to the need for periodic maintenance, but it is known the high cost of implementing these maintenances. Because of concerns with the maintenance and expense of concrete structures, this study aimed to perform a validation of the corrosion by chlorides in reinforced concrete structures from the meta-analysis of data from electrochemical techniques used in the work of theses and dissertations developed in Brazil. The aim is thus to map the research on corrosion in reinforced concrete made in Brazil and direct future studies. Also perform a joint analysis of all these works to verify the quantity and quality of these in a vision of the National Assembly. We observed the lack of research in the northern region of the country and centralizing them in the Southeast and South By using statistical techniques concludes the lack of various combinations of variables (water / cement ratio, cement type, method induction of chloride, addition of materials, among others) to create a Brazilian model reliable.

Page generated in 0.3571 seconds