• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 101
  • 3
  • Tagged with
  • 104
  • 104
  • 29
  • 27
  • 25
  • 21
  • 18
  • 18
  • 18
  • 16
  • 15
  • 15
  • 15
  • 14
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Simulação experimental da interação vento-chuva / Experimental simulation of the wind-rain interaction

Rupp, Henrique Luiz January 2010 (has links)
Simultâneas ocorrências da ação combinada de chuva e vento em diferentes tipos de estruturas têm sido observadas ao redor do mundo nos últimos 20 anos. Este mecanismo tem despertado curiosidade aos engenheiros e pesquisadores devido às suas conseqüências nefastas para as edificações. Nestes últimos vinte anos passou-se a procurar uma maneira de simular, o mais fielmente possível, este tipo de ação combinada de chuva e vento. Isto ocorreu devido ao fato de que a busca por soluções dos problemas relacionados à ação combinada de vento e chuva basearem-se em métodos empíricos (tipo tentativa e erro). Este tipo de problema, que aos olhos mais descuidados pode parecer pequeno, pode provocar desde pequenos problemas de infiltração de água em edificações até o comprometimento da vida útil de uma estrutura devido o ataque da água, agente corrosivo. O melhor conhecimento do fenômeno através de ensaios experimentais permitirá a engenheiros a identificação deste tipo de problema já na fase de projeto e conseqüentemente a medida paliativa ao mesmo. Para estudo deste fenômeno foi utilizado um modelo ginásio existente na cidade do Rio de Janeiro, que apresentava problema de penetração de chuva devido à ação combinada de chuva e vento. Foram utilizados dois modelos em escala reduzida do ginásio supracitado. O primeiro modelo, construído em escala 1/150 foi instrumentado com sensores de fio-quente para identificar as características do escoamento sobre a estrutura, e um segundo modelo na escala 1/64, instrumentado com um papel especial sensível a água, onde foram realizados os ensaios combinando a ação de chuva e vento. Os ensaios utilizando o modelo em escala 1/150 foram realizados para ângulos de incidência do vento variando de 15o em 15o. Visando o estudo do comportamento da interação chuva e vento, foram realizados três grupos de ensaios. Num primeiro grupo de ensaios, o modelo foi apenas exposto à chuva e os locais onde existia percolação de água identificados. Após o modelo foi novamente ensaiado, desta vez com a ação combinada de chuva e vento, para duas configurações de dispositivos protetores. A partir da análise dos resultados, pode-se concluir que a simulação experimental do processo de interação vento-chuva é possível, e que mais ensaios são necessários para o entendimento do processo. / Simultaneous occurrences of the combined action of rain and wind in different types of structures have been observed around of the world in the last 20 years. This mechanism has been causing curiosity to engineers and researchers due to their jeopardizing consequences to constructions. In these last twenty years people has been seeking for a way to simulate, the most faithfully possible, this type of combined action of rain and wind. This happened due to the fact that the search for solutions to the problems related to the combined action of wind and rain were based on empirical methods (trial and error type). This kind of problem, that may seem small to the most careless eyes, may cause since small water infiltration problems in buildings, up to the own safety of the structure due to the action of water, a corrosive agent. The better knowledge of the phenomenon through experimental tests will allow engineers the problem identification already in the design phase and consequently a palliative solution to it. For the study of this phenomenon, a model of an existent gymnasium in city of Rio de Janeiro was used. Two reduced scale models of the gymnasium were used. The first model, built in a 1/150 scale was instrumented with hot-wire probes to identify the flow characteristics, and the second model, in the scale 1/64, was instrumented with a special water sensitive paper, where the tests were accomplished combining the rain and wind action. The tests for the model in scale 1/150 were performed for wind incidences intervals of 15o. With the aim of study the behavior of the wind-rain interaction, three groups of tests were performed. After that, the model was again tested for two configurations of protective devices. From the analysis of the results, it is possible to conclude that the experimental simulation of the wind-rain interaction process is possible, and that more tests are necessary to understand the process.
92

Manifestações patológicas em empreendimentos habitacionais de baixa renda executados em alvenaria estrutural : uma análise da relação de causa e efeito / Building pathologies in low cost housing projects with structural masonry: an analysis of the cause-effect relationship

Alexandre, Ilídio Francisco January 2008 (has links)
A alvenaria estrutural vem ganhando um grande impulso no Brasil ao longo das últimas décadas, sendo cada vez mais utilizada, principalmente em empreendimentos habitacionais de interesse social. No caso específico do Estado do Rio Grande do Sul, nos últimos dois anos, a maioria dos empreendimentos habitacionais de baixa renda foram executados com esse processo construtivo. Por exigência dos órgãos financiadores destes tipos de empreendimentos, as empresas construtoras dos mesmos devem ser possuidoras de certificação do seu sistema de gestão da qualidade. Entretanto, apesar desta certificação, tem-se observado a presença de manifestações patológicas, com predominância de fissuras, nos empreendimentos de baixa renda, por elas executadas. As causas das manifestações patológicas em empreendimentos construídos em alvenaria estrutural têm sido objeto de estudo de diversas pesquisas. Porém, não se fez até então um estudo das possíveis causas destas manifestações do ponto de vista multicausal, envolvendo as várias etapas do processo construtivo. Neste sentido, a presente pesquisa teve como objetivo principal analisar as relações de causa e efeito entre as fissuras dos empreendimentos construídos em alvenaria estrutural e as suas causas, utilizando-se de ferramentas de melhorias da qualidade que adotam uma visão multi-casual, muito utilizadas em outras indústrias Para este estudo foram utilizados relatórios de monitoramento de execução de empreendimentos que pertencem aos modos de provisão habitacional do Programa de Arrendamento Residencial (PAR) e Imóvel na Planta (IP), no Estado do Rio Grande do Sul, ambos gerenciados pela Caixa Econômica Federal. A pesquisa consistiu em: (a) revisão bibliográfica; (b) levantamento e análise dos dados provenientes dos relatórios, identificando falhas, recomendações técnicas e boas práticas adotadas pelas empresas construtoras; (c) aplicação de um método de análise de relações de causa e efeito composto por ferramentas da qualidade; e (d) geração de mapas de relações de causa e efeito, recomendações para tratamento das principais causas e listagem de algumas boas práticas construtivas. Através desta pesquisa foi possível verificar as principais falhas ao longo do processo construtivo em vários níveis de análise e analisar as relações de causa e efeito entre eles e propor uma priorização de melhorias da qualidade. Com base nesta priorização foi sistematizado um conjunto de recomendações técnicas e de boas práticas que podem ser disseminadas entre as empresas construtoras tendo em vista a melhoria da qualidade dos empreendimentos em estudo. / Structural masonry has had a substantial development in Brazil in the last few decades, becoming increasingly important, especially in social interest housing projects. In the specific case of Rio Grande do Sul, in the last two years, most low cost housing projects have been built using this construction process. Due to the demand of the funding organizations, the construction companies that build those projects must have a certified quality management system. However, despite this certification, a large number of building pathologies have been observed in those projects, especially cracks. In fact, the causes of building pathologies in structural masonry buildings have been the focus of several research studies. However, very little has been investigated on the causes of those pathologies from a multi-causal perspective, considering several stages of the construction process. The main objective of this research work is to analyze the cause-effect relationships between cracks in structural masonry buildings and their causes, using quality improvement tools that provide such multi-causal perspective, widely used in other industries. This study was based on quality monitoring reports of projects from two housing programs, the Residential Leasing Program (PAR) and the Blue-print Program (IP), in the State of Rio Grande do Sul. Both programs are managed by the National Savings Bank. The research study consisted of: (a) a literature review; (b) data collection and analysis using those reports, with the aim of identifying building failures, necessary improvements, and good practices adopted by construction companies; (c) application of a method for analyzing the cause-effect relationships which combined a set of quality tools; (d) development of cause-effect relationship maps, proposition of a set of improvements and a production of a list of good practices. Based on this study, it was possible to identify failures in the construction process, as well as to analyze the cause-effect relationships and propose some priorities in terms of improvements measures. Based on those priorities, a set of technical recommendations was established, as well as a list of good practices that should be disseminated among construction companies, in order to improve the quality of low-cost housing projects.
93

Aporte al estudio sobre la incidencia de los fenomenos patologicos en puentes de hormigon armado en el Uruguay

Franco, José Claudio Barboza January 2012 (has links)
The study of pathological manifestations in concrete emerges as a valuable tool for understanding the processes involved, in it as long as it makes possible to optimize its use in all stages of the construction process. Under this circumstance it was considerate valid to make a survey about the major damages in Uruguay, for which 93 reports were labeled with 313 assessments on 147 bridges in the period 2004 / 2010. From their analyst’s it was verified of injury "Corrosion of reinforcement", located mainly in the coastal South. Makeover, it was found that "Board" is the most affected of the elements followed by “Side Shields" and "Sidewalks", where "Exposed reinforcement" and "Humidity stains" are the most prevalent problems. / El estudio de las manifestaciones patológicas en el hormigón armado surge como una valiosa herramienta para la comprensión de los procesos involucrados, en la medida que posibilita optimizar su uso en todas las etapas del proceso constructivo. En función de esta circunstancia entendió-se valedero realizar un levantamiento de sus principales daños en el Uruguay, para lo cual fueron catalogados 93 informes con 313 evaluaciones sobre 147 puentes en el periodo 2004 / 2010. De su análisis verifico-se la preeminencia de la lesión “Corrosión de armaduras”, la que se localiza principalmente en la zona costera Sur. A sí mismo, constata-se que “Tablero” es el elemento más afectado de estas estructuras seguido por “Protección lateral” y “Veredas”, donde “Armadura expuesta” y “Manchas de humedad” son las lesiones más relevantes.
94

Metodologia de Inspeção em Estruturas de Pontes de Concreto Armado / Methodology for inspection of concret bridges

EUQUERES, Priscilla 25 November 2011 (has links)
Made available in DSpace on 2014-07-29T15:03:34Z (GMT). No. of bitstreams: 1 Dissertacao_Priscilla Euqueres - pre textual.pdf: 132659 bytes, checksum: b6f2adfbed9691f924350c313a19a065 (MD5) Previous issue date: 2011-11-25 / The objective this work is to develop and implement a methodology for special inspection on Concrete Bridges trough the quantitative analysis of the degree of deterioration of the structures so that it can serve as a basis for making decisions related to the rehabilitation of these structures. In order to develop and apply the methodology on concrete bridges, the existing methods of inspection of concrete structures were studied and adapted to the adapting to the concrete bridges. The methodology was based on GDE/UnB model in their latest formulation (Fonseca,2007) and adapted to the tables with the elements to be analyzed, together with the pathological manifestations that can occur in each element, timing and interventions classification of the level of deterioration and the relevant factors to each family of concrete bridges. A pilot study was proposed to validate the methodology. Results showed that there was a need for further adaptation, to consider the caculations of the degree of deterioration of both the family or the. With the changes proposed in the pilot study were made over 11 (eleven) inspections in order to validate the proposed methodology. With the results obtained it was concluded that the methodology for inspection of bridges is valid and of great importance to public organisms and surveyors to make decisions about the best time and the best item to be rehabilitated, being a single element, as a family elements, or the structure as a whole. One downside is that the methodoly for bridges with lenght greater than 70 meters most be used with caution, because the median openings are difficult to visual assessment. However the methodology can be used in order to obtain basic understanding of the visible elements, and after the intervention, we can make another more detailed analysis using not only the elements of routine inspection as binoculars, measuring tape, camera, among others, but also nautical elements, which provide the best viewing responsible for the inspection of the median elements / O objetivo deste trabalho é desenvolver e aplicar uma metodologia para inspeção especial das estruturas de pontes de concreto armado por meio da análise quantitativa do grau de deterioração das estruturas para que esta possa servir de embasamento para tomada de decisões relacionadas à reabilitação. Para desenvolver e aplicar a metodologia em estruturas de pontes de concreto armado foram realizados estudos de metodologias de inspeção em estruturas já existentes, adequando-as à estrutura de pontes. Tomou-se como base e modelo a metodologia GDE/UnB em sua última formulação (Fonseca, 2007) e adaptaram-se as tabelas com os elementos a serem analisados, juntamente com as manifestações patológicas que podem ocorrer em cada elemento, prazos para intervenções e intervalos para classificação quanto ao nível de deterioração e os fatores de relevância para cada família de elementos das estruturas de pontes. Para validar a metodologia proposta fez-se um Estudo Piloto, onde foi verificada a necessidade de uma adaptação, envolvendo os cálculos dos graus de deterioração tanto da família quanto da estrutura como um todo. Com as modificações propostas no Estudo Piloto foram feitos outras 11 (onze) inspeções a fim de validar a metodologia proposta. Com os resultados obtidos concluiu-se que a metodologia desenvolvida para inspeções de pontes é válida e de grande importância para que órgãos públicos e vistoriadores tomem decisões quanto ao melhor prazo e melhor elemento estrutural a ser reabilitado, podendo ser ele um elemento isolado, uma ou mais família de elementos ou a estrutura como um todo. Um ponto negativo da metodologia é que, para pontes com extensão maior que 70m, sua utilização fica comprometida, pois os vãos medianos são difíceis de avaliação visual. Entretanto a metodologia pode ser utilizada para que se obtenha uma avaliação preliminar dos elementos visíveis e, após intervenção, pode-se fazer outra análise mais minuciosa utilizando não só os elementos de inspeção rotineira como: binóculos, trena, câmera fotográfica com zoom, entre outros, mas também elementos náuticos, os quais proporcionam ao responsável pela inspeção melhor visualização dos elementos medianos.
95

Reabilitação em edifícios e monumentos art déco – métodos de avaliação dos revestimentos de fachadas / Rehabilitation in buildings and monuments art deco - methods for evaluation of facades renderings

Munduruca, Elianne Auxiliadora Moreira Borges 22 August 2013 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2014-12-15T20:22:31Z No. of bitstreams: 5 Dissertação - Elianne Auxiliadora Moreira Borges Munduruca - 2013 (1).pdf: 10525561 bytes, checksum: 07a8e4382df564fbf83da2a21bf32527 (MD5) Dissertação - Elianne Auxiliadora Moreira Borges Munduruca - 2013 (2).pdf: 10283132 bytes, checksum: 86891a8fb2cc6787c47e68abef54a9b7 (MD5) Dissertação - Elianne Auxiliadora Moreira Borges Munduruca - 2013 (3).pdf: 9957787 bytes, checksum: 8f10cc9b353e9438eb3f56aa2c31f367 (MD5) Dissertação - Elianne Auxiliadora Moreira Borges Munduruca - 2013 (4).pdf: 263110 bytes, checksum: 54511210b516c244f2746115cef2570f (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2014-12-15T20:22:58Z (GMT) No. of bitstreams: 5 Dissertação - Elianne Auxiliadora Moreira Borges Munduruca - 2013 (1).pdf: 10525561 bytes, checksum: 07a8e4382df564fbf83da2a21bf32527 (MD5) Dissertação - Elianne Auxiliadora Moreira Borges Munduruca - 2013 (2).pdf: 10283132 bytes, checksum: 86891a8fb2cc6787c47e68abef54a9b7 (MD5) Dissertação - Elianne Auxiliadora Moreira Borges Munduruca - 2013 (3).pdf: 9957787 bytes, checksum: 8f10cc9b353e9438eb3f56aa2c31f367 (MD5) Dissertação - Elianne Auxiliadora Moreira Borges Munduruca - 2013 (4).pdf: 263110 bytes, checksum: 54511210b516c244f2746115cef2570f (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2014-12-15T20:23:01Z (GMT). No. of bitstreams: 5 Dissertação - Elianne Auxiliadora Moreira Borges Munduruca - 2013 (1).pdf: 10525561 bytes, checksum: 07a8e4382df564fbf83da2a21bf32527 (MD5) Dissertação - Elianne Auxiliadora Moreira Borges Munduruca - 2013 (2).pdf: 10283132 bytes, checksum: 86891a8fb2cc6787c47e68abef54a9b7 (MD5) Dissertação - Elianne Auxiliadora Moreira Borges Munduruca - 2013 (3).pdf: 9957787 bytes, checksum: 8f10cc9b353e9438eb3f56aa2c31f367 (MD5) Dissertação - Elianne Auxiliadora Moreira Borges Munduruca - 2013 (4).pdf: 263110 bytes, checksum: 54511210b516c244f2746115cef2570f (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2013-08-22 / Facade rendering perform various functions in buildings and monuments including aesthetic features, durability and economic value. However, over the years, the works begin to suffer deterioration processes, either natural or caused by unsuccessful intervention actions that trigger the onset of problems in the building rendering works, impairing these functions. In the case of historical buildings and monuments, the situation is even worse, because of the lack of knowledge of materials and techniques employed in implementing them at the time of construction. Thus, this thesis aims to study the most suitable methods for the inspection of works on facades and monuments of historical value and, from this research, aims to adapt a simplified methodology for the assessment of pathological manifestations of renderings, especially in art deco construction style built in Goiânia. To achieve this goal, was designed a case study in the Clock Tower, an important art deco monument of the capital of the Brazilian state of Goiás, has been proposed the following methodology: visual inspection for research and mapping of pathological manifestations present at the monument; photographic documentation; essay by percussion, to assess the state of rendering adhesion; application of the infrared thermograph technique; and also testing by pendulum sclerometry to evaluate the surface hardness of the rendering. As a result, it was found that the monument is deteriorated with the presence of various defects in the rendering, especially with a high cracking and dirt stains, and rust stains and disintegration. The south and north views of the tower are those most committed while in the west and east views, especially in the latter, the rendering is still in good condition. / Os revestimentos de fachadas exercem diversas funções nos edifícios e monumentos, entre as quais, funções estéticas, de durabilidade e de valorização econômica. Entretanto, com o passar dos anos, as obras começam a sofrer processos de deterioração, ora naturais ora provocados por ações de intervenção mal sucedidas, que desencadeiam o aparecimento de diversos problemas no revestimento, comprometendo essas funções. No caso dos edifícios e monumentos históricos, a situação é ainda pior, pois se somam a esses fatores, a falta de conhecimento dos materiais e das técnicas empregadas na execução deles na época da construção. Dessa forma, esta dissertação tem como objetivo estudar os métodos mais adequados para a inspeção em fachadas de obras e monumentos de valor histórico e, a partir dessa investigação, adaptar uma metodologia simplificada destinada à avaliação das manifestações patológicas dos revestimentos, especialmente de obras do estilo art déco construídas em Goiânia. Para o alcance desse objetivo, foi idealizado um estudo de caso na Torre do Relógio, importante monumento art déco da capital goiana, tendo sido proposta a seguinte metodologia: inspeção visual, para investigação e mapeamento das manifestações patológicas presentes no monumento; documentação fotográfica; ensaio por percussão, para avaliar o estado de aderência do revestimento; aplicação da técnica da termografia infravermelha e, ainda, o ensaio de esclerometria de pêndulo, para avaliar a dureza superficial do revestimento. Como resultado, constatou-se que o monumento encontra-se deteriorado, com a presença de diversas anomalias no revestimento, principalmente, com elevado índice de fissuração e manchas de sujidade, além de manchas de oxidação e desagregação. As vistas Sul e a Norte são as que estão mais comprometidas enquanto que nas vistas Oeste e Leste, especialmente nesta última, o revestimento ainda continua em bom estado de conservação.
96

DESEMPENHO A ESTANQUEIDADE À ÁGUA: INTERFACE JANELA E PAREDE / WATER RESISTANCE PERFORMANCE: WINDOW AND WALL INTERFACE

Luduvico, Thesse Souza 08 June 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This present study aims to evaluate the design and execution process of windows focused on performance for leaks in the window to wall interface. The methodology used for this qualitative study was the comparative method through literature and survey research. The data collection instrument used was direct observation and application form. The results reported a wide incidence of failures in the design phase and execution, for which have been developed technical recommendations aimed at reducing or eliminating pathological manifestations affecting the surrounding frames. It concludes that the processes consolidated in the Brazilian construction industry need to undergo changes throughout the production chain so that there is compatibility between the components of a construction work, including the design and installation frames. As a result, failures resulting from poor detailing and improvisations on the construction site are reduced and therefore generate an improvement in quality, performance and service life of buildings. / O presente estudo tem como objetivo a avaliação do processo de projeto e execução de janelas com foco no desempenho quanto à estanqueidade à água da conexão janela/parede de vedação. A metodologia utilizada nesta pesquisa foi o método qualitativo por meio de pesquisa bibliográfica e levantamento. Como técnica de coleta de dados foi utilizada a observação direta e formulário. Os resultados relataram uma ampla incidência de falhas na fase de projeto e execução, para as quais, foram desenvolvidas recomendações técnicas visando à redução ou eliminação de manifestações patológicas que afetam o entorno às esquadrias. Conclui-se que os processos consolidados na construção civil brasileira precisam passar por mudanças em toda a cadeia produtiva para que exista uma compatibilização entre os componentes de uma obra, incluindo o projeto e instalação de esquadrias. Assim, falhas resultantes de detalhamentos deficientes e improvisos no canteiro de obras são reduzidas e, por conseguinte, geram uma melhoria na qualidade, desempenho adequado e vida útil projetada das edificações.
97

Análise quantitativa da degradação de fachadas em revestimento cerâmico: estudo de caso em edifícios de Belém– PA / Quantitative analysis of façade degradation in ceramic tiling: case study in buildings in Belém– PA

SANTOS NETTO, Clementino José dos 15 June 2018 (has links)
Submitted by Kelren Mota (kelrenlima@ufpa.br) on 2018-08-31T20:13:35Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseQuantitativaDegradacao.pdf: 6804477 bytes, checksum: 0896be3e55793c655408b43519e639c4 (MD5) / Approved for entry into archive by Kelren Mota (kelrenlima@ufpa.br) on 2018-08-31T20:14:11Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseQuantitativaDegradacao.pdf: 6804477 bytes, checksum: 0896be3e55793c655408b43519e639c4 (MD5) / Made available in DSpace on 2018-08-31T20:14:12Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseQuantitativaDegradacao.pdf: 6804477 bytes, checksum: 0896be3e55793c655408b43519e639c4 (MD5) Previous issue date: 2018-06-15 / Este estudo aborda o levantamento e a identificação de manifestações patológicas nas fachadas de cinco edifícios, com sistema de revestimento cerâmico (SRC), da Região Metropolitana de Belém/ PA, por meio do modelo de quantificação de danos adaptado de Silva (2014). A metodologia proposta consiste em uma sistematização do processo de inspeção, com identificação, mapeamento e quantificação das manifestações patológicas nas fachadas dos edifícios, aplicando o Fator de Danos (FD) como forma de avaliar o comportamento da degradação em função de fatores de influência como o tipo de manifestação, idade e orientação solar das fachadas, analisando também agentes de degradação como a chuva dirigida, radiação solar e umidade. Posteriormente, foi aplicado o Fator de Danos Combinado (FDC) que atribui índices de ponderação ao FD, relativos ao custo de reparação de cada anomalia observada. Analisando os resultados, verificou-se que a manifestação patológica manchas (MA) no revestimento cerâmico foi a que apresentou maior percentual de ocorrência, ou seja, maior área degradada, entre os tipos de anomalias observadas. Além disso, essa manifestação apresentou valores elevados de FDMédio em todas as orientações cardeais e valores expressivos desse índice de degradação, tanto nas fachadas com menos de 20 anos, quanto nas com mais de 20 anos. Esses resultados são diretamente influenciados pelo clima extremamente agressivo da região, que apresenta constantes chuvas e elevada umidade relativa do ar (atingindo até 95%), favorecendo a propagação dessa anomalia (manchamento) já nas primeiras idades da edificação, visto que, as fachadas mais jovens analisadas (10 e 16 anos) já possuíam índices de degradação consideráveis essa manifestação patológica. A orientação que apresentou maior fator de degradação foi a direção Sul (FDTotal=9,42%), influenciado diretamente pelo fenômeno da chuva dirigida, que apresenta seu maior Índice de Chuva Dirigida (ICD) na direção Norte, afetando as fachadas orientadas na direção Sul. Após a aplicação do FDC, a manifestação patológica descolamento/ desplacamento (DC) cerâmico passou a apresentar o maior índice de degradação (FDCMédio=39,22%), devido ao seu alto custo de restauração, quando comparado ao valor de reparo das outras anomalias avaliadas. Por meio dos histogramas de FDTotal e FDCTotal, observou-se uma curva exponencial característica que apresenta uma diminuição na frequência de ocorrência à medida que aumenta o valor do índice de degradação. Tal curva característica também foi observada em Silva (2014) e Souza (2016). / This study approaches the collect and identification of pathological manifestations in the façades of five buildings, with ceramic coating system (SRC), in the Metropolitan Region of Belém / PA, using Silva 's adapted damage quantification model (2014). The proposed methodology consists of a systematization of the inspection process, with identification, mapping and quantification of the pathological manifestations in the façades of the buildings, applying the Damage Factor (FD) as a way to evaluate the degradation behavior as a function of influence factors such as type of manifestation, age and solar orientation of the facades, also analyzing agents of degradation such as directed rain, solar radiation and humidity. Subsequently, the Combined Damage Factor (FDC) was applied, which assigns weighting indices to the FD, related to the repair cost of each observed anomaly. Analyzing the results, it was verified that the pathological manifestation stain (MA) on the ceramic coating was the one that presented the highest percentage of occurrence, that is, greater degraded area, among the types of anomalies observed. In addition, this manifestation presented high values of FDC in all cardinal orientations and expressive values of this index of degradation, both in façades under 20 years and in those with more than 20 years. These results are directly influenced by the extremely aggressive climate of the region, which presents constant rains and high humidity (up to 95%), favoring the propagation of this anomaly (staining) already in the first ages of the building, since the façades (10 and 16 years old) already had considerable degradation rates of this pathological manifestation. The orientation that presented the highest degradation factor was the South direction (FDTotal=9.42%), influenced directly by the phenomenon of directed rainfall, which presents its highest Directed Rain Index (ICD) in the North direction, affecting the facades oriented in the South direction. After the application of FDC, the pathological manifestation of ceramic detachment / displacement (DC) presented the highest degradation index (FDCMédio=39.22%), due to its high restoration cost, when compared to the repair value of the other anomalies evaluated. By means of the histograms of FDTotal and FDCTotal, a characteristic exponential curve was observed that shows a decrease in the frequency of occurrence as the value of the degradation index increases. This characteristic curve was also observed in Silva (2014) and Souza (2016).
98

Análise de desempenho de algoritmos para auxílio ao reconhecimento de fissuras em fachadas com revestimento de argamassa visando sua embarcação em VANTs

Pereira, Fábio Celestino January 2015 (has links)
A utilização de Veículos Aéreos Não Tripulados (VANTs), também chamados UAV (Unmanned Aerial Vehicle) vem ganhando espaço nas mais diversas áreas, tais como inspeções em linhas de transmissão e em torres de fracionamento de refinarias, entre outros. Já na construção civil, estudos recentes estão sendo focados na utilização dos VANTs para inspeção de pontes, viadutos e estradas. O presente trabalho visa fornecer uma análise para o uso de VANT na área civil, na detecção de manifestações patológicas em revestimentos de argamassa, de forma a auxiliar na procura por fissuras em fachadas, sobretudo aqueles que a visualização esteja prejudicada, seja pela distância ou pela acessibilidade difícil ao local. Este trabalho analisa possíveis implementações de dois algoritmos de processamentos de imagens desenvolvidos a partir da ferramenta MATLAB para a indicação de presença de fissuras na alvenaria, obtendo o desempenho destes diferentes algoritmos quando executados em software em plataforma que possibilite a embarcação em VANTs. Utilizando a geração automática de código em C a partir do ambiente MATLAB, é realizada uma análise temporal em plataforma ARM e RISC dos algoritmos propostos, demonstrando a oportunidade de utilização de dispositivos na tarefa de processamento de imagem para a aplicação proposta. Esta análise possibilita a previsão do comportamento na utilização de um VANT, uma vez que isto pode impactar na velocidade durante a aplicação e consequentemente sua autonomia. / The use of Unmanned Aerial Vehicles (UAVs), has been gaining space in several areas, such as inspections of transmission lines, refineries fractionation towers among others. In the construction, recent studies have been focused on the use of UAVs for inspection of bridges, viaducts and roads. The present study aims to provide an analysis using UAVs in the civil construction area, in the detection of pathologic manifestations mortar coatings in order to aid in the search for cracks in the facades especially those that visualization is impaired, or may be the distance the accessibility difficult to spot. This paper provides an analysis of two algorithms of image processing developed from the Matlab tool for indicating the presence of cracks in masonry, getting the performance of these different algorithms when implemented in software platform that enables the vessel in UAV. Using the automatic generation of C/C++ code from the MATLAB environment is performed the temporal analysis on ARM and RISC plataform of the proposed algorithms demonstrates the opportunity to use devices in the image processing task for the proposed application. This analysis allows the prediction of the behavior of a UAV using one since it can impact velocity during application, and therefore their autonomy.
99

Consideração do esmagamento do concreto através do modelo de trincas sobrepostas / Consideration of the concrete crushing through the overlapping crack model

Evangelho, Tiago Becker January 2013 (has links)
Neste trabalho é apresentada uma teoria para a consideração do esmagamento do concreto aplicada ao método elementos finitos, o Modelo de Trincas Sobrepostas. Neste caso, o esmagamento é considerado através da interpenetração dos elementos finitos. Em conjunto com o já conhecido Modelo de Trincas Coesivas, a abordagem é utilizada para simular o comportamento de vigas de concreto armado com alta taxa de armadura (concreto superarmado). Os experimentos empregados são vigas em flexão a três pontos (dois apoios e uma carga aplicada no centro do vão), onde as barras de aço são substituídas por uma camada de elementos finitos de altura equivalente. Aloca-se uma linha de elementos de interface coesiva verticalmente no centro das vigas no intuito de permitir o processo de dano, tanto em tração quanto em compressão. Na zona de interface entre os elementos de concreto e os de aço são colocados elementos de aderência. É verificada a influência nos modelos numéricos de diversos parâmetros, tais como altura da viga, armadura de compressão, armadura de cisalhamento e escala. / In this work is presented a theory to the consideration of the concrete crushing applied to the finite element method, the Overlapping Crack Model. In this case the crushing is considered through the interpenetration of finite elements. Together with the well-known Cohesive Crack Model, the approach is used to simulate the behavior of reinforced concrete beams with high volume fraction of reinforcement (under reinforced concrete). The used experiments are beams subjects to three-point bending, where the steel bars are replaced by an equivalent layer of finite elements. A central vertical line of interfaces is used in order to take into account the damage due to crushing and fracture. At the concrete-steel interface, friction elements are considered. The influence of some parameters, such as depth of the beam, compression and shear reinforcement, etc., is investigated.
100

Consideração do esmagamento do concreto através do modelo de trincas sobrepostas / Consideration of the concrete crushing through the overlapping crack model

Evangelho, Tiago Becker January 2013 (has links)
Neste trabalho é apresentada uma teoria para a consideração do esmagamento do concreto aplicada ao método elementos finitos, o Modelo de Trincas Sobrepostas. Neste caso, o esmagamento é considerado através da interpenetração dos elementos finitos. Em conjunto com o já conhecido Modelo de Trincas Coesivas, a abordagem é utilizada para simular o comportamento de vigas de concreto armado com alta taxa de armadura (concreto superarmado). Os experimentos empregados são vigas em flexão a três pontos (dois apoios e uma carga aplicada no centro do vão), onde as barras de aço são substituídas por uma camada de elementos finitos de altura equivalente. Aloca-se uma linha de elementos de interface coesiva verticalmente no centro das vigas no intuito de permitir o processo de dano, tanto em tração quanto em compressão. Na zona de interface entre os elementos de concreto e os de aço são colocados elementos de aderência. É verificada a influência nos modelos numéricos de diversos parâmetros, tais como altura da viga, armadura de compressão, armadura de cisalhamento e escala. / In this work is presented a theory to the consideration of the concrete crushing applied to the finite element method, the Overlapping Crack Model. In this case the crushing is considered through the interpenetration of finite elements. Together with the well-known Cohesive Crack Model, the approach is used to simulate the behavior of reinforced concrete beams with high volume fraction of reinforcement (under reinforced concrete). The used experiments are beams subjects to three-point bending, where the steel bars are replaced by an equivalent layer of finite elements. A central vertical line of interfaces is used in order to take into account the damage due to crushing and fracture. At the concrete-steel interface, friction elements are considered. The influence of some parameters, such as depth of the beam, compression and shear reinforcement, etc., is investigated.

Page generated in 0.1079 seconds