1 |
Productivity Assessment of a Nanofiltration Membrane Process Treating Unaerated or Aerated GroundwaterBrummer, Gabriele A 01 January 2024 (has links) (PDF)
This document details the results of a study that employed a single element, spiral-wound, thinfilm composite nanofiltration (NF) membrane pilot to assess the treatment effectiveness for aerated and unaerated groundwater supplies. Phase 1 consisted of using raw, unaerated groundwater with standard cartridge filtration (CF) and scale inhibitor (SI) as pretreatment to NF. During the first phase, four water recoveries and crossflow velocities were evaluated to observe how operational conditions affected permeate water quality. Phase 2 involved the simulation of a 70-foot transmission pipeline and sand filter (SF) pilot in series with CF and SI addition pretreatment, prior to NF. Phase 3 employed tray aeration prior to the SF pilot. The pilot was operated for 1,483 run-hours over the three phases, whereupon operational and water quality monitoring ensued to assess NF efficiency. Biological activity tests and foulant analyses were performed to further characterize source water. It was determined statistically that changes in operational conditions in Phase 1 such as crossflow velocity did not significantly affect constituent mass transfer. Phase 2 demonstrated that NF removed total dissolved solids and total organic carbon content greater than 96 percent (%) and 86%, respectively. Phase 3, which exhibited operational difficulties and flux decline, suggested that additional pretreatment is required for NF operation using aerated groundwater. Dimensional analysis (DA) and diffusionbased mass transfer models were employed to predict permeate chloride content for each testing phase; it was determined that the DA overpredicted chloride concentrations by 10 magnitudes and diffusion models were predictive when compared to actual values. The transient response to feed water perturbations within the single-stage membrane process was determined to cause a log-logistic two-and-a-half-minute delay.
|
2 |
Contribution à l'étude des transferts de matière gaz-liquide en présence de réactions chimiques/Contribution to the gas-liquid mass transfer study coupled with chemical reactionsWylock, Christophe E M 29 September 2009 (has links)
Le bicarbonate de soude raffiné, produit industriellement par la société Solvay, est fabriqué dans des colonnes à bulles de grande taille, appelées les colonnes BIR.
Dans ces colonnes, une phase gazeuse contenant un mélange d’air et dioxyde de carbone (CO2) est dispersée sous forme de bulles dans une solution aqueuse de carbonate et de bicarbonate de sodium (respectivement Na2CO3 et NaHCO3). Cette dispersion donne lieu à un transfert de CO2 des bulles vers la phase liquide. Au sein des colonnes, la phase gazeuse se répartit dans deux populations de bulles : des petites bulles (diamètre de quelques mm) et des grandes bulles (diamètre de quelques cm). Le transfert bulle-liquide de CO2 est couplé à des réactions chimiques prenant place en phase liquide, qui conduisent à la conversion du Na2CO3 en NaHCO3. Une fois la concentration de saturation dépassée, le NaHCO3 précipite sous forme de cristaux et un mélange liquide-solide est recueilli à la sortie de ces colonnes.
Ce travail, réalisé en collaboration avec la société Solvay, porte sur l’étude et la modélisation mathématique des phénomènes de transfert de matière entre phases, couplés à des réactions chimiques, prenant place au sein d’une colonne BIR. L’association d’études sur des colonnes à bulles à l’échelle industrielle ou réduite (pilote) et d’études plus fondamentales sur des dispositifs de laboratoire permet de développer une meilleure compréhension du fonctionnement des colonnes BIR et d’en construire un modèle mathématique détaillé.
L’objectif appliqué de ce travail est la mise au point d’un modèle mathématique
complet et opérationnel d’une colonne BIR. Cet objectif est supporté par trois blocs
de travail, dans lesquels différents outils sont développés et exploités.
Le premier bloc est consacré à la modélisation mathématique du transfert bulle-liquide de CO2 dans une solution aqueuse de NaHCO3 et de Na2CO3. Ce transfert est couplé à des réactions chimiques en phase liquide qui influencent sa vitesse.
Dans un premier temps, des modèles sont développés selon des approches unidimensionnelles
classiquement rencontrées dans la littérature. Ces approches passent par une idéalisation de l’écoulement du liquide autour des bulles. Une expression simplifiée de la vitesse du transfert
bulle-liquide de CO2, est également développée et validée pour le modèle de colonne BIR.
Dans un second temps, une modélisation complète des phénomènes de transport (convection
et diffusion), couplés à des réactions chimiques, est réalisée en suivant une approche
bidimensionnelle axisymétrique. L’influence de la vitesse de réactions sur la vitesse de transfert
est étudiée et les résultats des deux approches sont également comparés.
Le deuxième bloc est consacré à l’étude expérimentale du transfert gaz-liquide de
CO2 dans des solutions aqueuses de NaHCO3 et de Na2CO3. A cette fin, un dispositif
expérimental est développé et présenté. Du CO2 est mis en contact avec des solutions aqueuses
de NaHCO3 et de Na2CO3 dans une cellule transparente. Les phénomènes provoqués en phase
liquide par le transfert de CO2 sont observés à l’aide d’un interféromètre de Mach-Zehnder.
Les résultats expérimentaux sont comparés à des résultats de simulation obtenus avec un des
modèles unidimensionnels développés dans le premier bloc. De cette comparaison, il apparaît
qu’une mauvaise estimation de la valeur de certains paramètres physico-chimiques apparaissant
dans les équations de ce modèle conduit à des écarts significatifs entre les grandeurs observées
expérimentalement et les grandeurs estimées par simulation des équations du modèle.
C’est pourquoi une méthode d’estimation paramétrique est également développée afin
d’identifier les valeurs numériques de ces paramètres physico-chimiques sur base des résultats expérimentaux. Ces dernières sont également discutées.
Dans le troisième bloc, nous apportons une contribution à l’étude des cinétiques de
précipitation du NaHCO3 dans un cristallisoir à cuve agitée. Cette partie du travail est réalisée en collaboration avec Vanessa Gutierrez (du service Matières et Matériaux de l’ULB).
Nous contribuons à cette étude par le développement de trois outils : une table de calcul Excel permettant de synthétiser les résultats expérimentaux, un ensemble de simulations de l’écoulement au sein du cristallisoir par mécanique des fluides numérique et une nouvelle méthode d’extraction des cinétiques de précipitation du NaHCO3 à partir des résultats expérimentaux. Ces trois outils sont également utilisés de façon combinée pour estimer les influences de la fraction massique de solide et de l’agitation sur la cinétique de germination secondaire du NaHCO3.
Enfin, la synthèse de l’ensemble des résultats de ces études est réalisée. Le résultat final est le développement d’un modèle mathématique complet et opérationnel des colonnes BIR. Ce modèle est développé en suivant l’approche de modélisation en compartiments, développée au cours du travail de Benoît Haut. Ce modèle synthétise les trois blocs d’études réalisées dans ce travail, ainsi que les travaux d’Aurélie Larcy (du service Transferts, Interfaces et Procédés de l’ULB) et de Vanessa Gutierrez. Les équations modélisant les différents phénomènes sont présentées, ainsi que la méthode utilisée pour résoudre ces équations. Des simulations des équations du modèle sont réalisées et discutées. Les résultats de simulation sont également comparés à des mesures effectuées sur une colonne BIR. Un accord raisonnable est observé.
A l’issue de ce travail, nous disposons donc d’un modèle opérationnel de colonne BIR. Bien que ce modèle doive encore être optimisé et validé, il peut déjà être utilisé pour étudier l’effet des caractéristiques géométriques des colonnes BIR et des conditions appliquées à ces colonnes sur le comportement des simulations des équations du modèle et pour identifier des tendances.
//
The refined sodium bicarbonate is produced by the Solvay company using large size bubble columns, called the BIR columns.
In these columns, a gaseous phase containing an air-carbon dioxyde mixture (CO2) is dispersed under the form of bubbles in an aqueous solution of sodium carbonate and sodium bicarbonate (Na2CO3 and NaHCO3, respectively). This dispersion leads to a CO2 transfer from the bubbles to the liquid phase. Inside these columns, the gaseous phase is distributed in two bubbles populations : small bubbles (a few mm of diameter) and large bubbles (a few cm of diameter).
The bubble-liquid CO2 transfer is coupled with chemical reactions taking places in the liquid
phase that leads to the conversion of Na2CO3 to NaHCO3. When the solution is supersaturated in NaHCO3, the NaHCO3 precipitates under the form of crystals and a liquid-solid mixture is extracted at the outlet of the BIR columns.
This work, realized in collaboration with Solvay, aims to study and to model mathematically the mass transport phenomena between the phases, coupled with chemical reactions, taking
places inside a BIR column. Study of bubble columns at the industrial and the pilot scale is
combined to a more fundamental study at laboratory scale to improve the understanding of
the BIR columns functioning and to develop a detailed mathematical modeling.
The applied objective of this work is to develop a complete and operational mathematical modeling of a BIR column. This objective is supported by three blocks of work. In each block, several tools are developed and used.
The first block is devoted to the mathematical modeling of the bubble-liquid CO2 transfer in an NaHCO3 and Na2CO3 aqueous solution. This transfer is coupled with chemical reactions in liquid phase, which affect the transfer rate.
In a first time, mathematical models are developed following the classical one-dimensional
approaches of the literature. These approaches idealize the liquid flow around the bubbles. A
simplified expression of the bubble-liquid CO2 transfer rate is equally developed and validated
for the BIR column model.
In a second time, a complete modeling of the transport phenomena (convection and diffusion) coupled with chemical reactions is developed, following an axisymmetrical twodimensional approach. The chemical reaction rate influence on the bubble-liquid transfer rate is studied and the results of the two approaches are then compared.
The second block is devoted to the experimental study of the gas-liquid CO2 transfer to NaHCO3 and Na2CO3 aqueous solutions. An experimental set-up is developed and presented. CO2 is put in contact with NaHCO3 and Na2CO3 aqueous solutions in a transparent cell. The phenomena induced in liquid phase by the CO2 transfer are observed using a Mach-Zehnder interferometer.
The experimental results are compared to simulation results that are obtained using one of
the one-dimensional model developed in the first block. From this comparison, it appears that
a wrong estimation of some physico-chemical parameter values leads to significative differences between the experimentally observed quantities and those estimated by simulation of the model equations. Therefore, a parametric estimation method is developed in order to estimate those parameters numerical values from the experimental results. The found values are then discussed.
In the third block is presented a contribution to the NaHCO3 precipitation kinetic study in a stirred-tank crystallizer. This part of the work is realized in collaboration with Vanessa Gutierrez (Chemicals and Materials Department of ULB).
Three tools are developed : tables in Excel sheet to synthetize the experimental results, a set of simulations of the flow inside the crystallizer by Computational Fluid Dynamic (CFD) and a new method to extract the NaHCO3 precipitation kinetics from the experimental measurements.
These three tools are combined to estimate the influences of the solid mass fraction and the flow on the NaHCO3 secondary nucleation rate.
Finally, the synthesis of all these results is realized. The final result is the development of a complete and operational mathematical model of BIR columns. This model is developed following the compartmental modeling approach, developed in the PhD thesis of Benoît Haut. This model synthetizes the three block of study realized in this work and the studies of Aurélie Larcy (Transfers, Interfaces and Processes Department of ULB) and those of Vanessa Gutierrez. The equations modeling the phenomena taking place in a BIR column are presented as the used method to solve these equations. The equations of the model are simulated and the results are discussed. The results are equally compared to experimental measurement realized on a BIR column. A reasonable agreement is observed.
At the end of this work, an operational model of a BIR column is thus developed. Although this model have to be optimized and validated, it can already be used to study the influences of the geometrical characteristics of the BIR columns and of the conditions applied to these columns on the behaviour of the model equation simulations and to identity tendencies.
|
3 |
Développement du préleveur passif pour la mesure du formaldehyde dans l'air en vue d'améliorer le diagnostic dans les environnements intérieursVignau-Laulhere, Jane 10 May 2016 (has links)
Depuis 2001 et la création d'un observatoire de la qualité de l'air intérieur (OQAI), la qualité de l'air intérieur est devenue un enjeu majeur de santé publique et fait l'objet d'un cadre réglementaire qui continue d'évoluer au cours des dernières années. Deux décrets récents, en France, prévoient la mise en œuvre de l'étiquetage des matériaux de construction en fonction de leurs émissions de composés organiques volatils (COV) (décret n° 2011-321, 23/03/2011) et le contrôle de la concentration des polluants (benzène et formaldéhyde) avec un guide des valeurs pour les bâtiments ouverts au public (n ° 2011-1728, 12/02/2012). De nos jours, la méthode analytique utilisée pour mesurer la concentration en formaldéhyde dans l'air consiste en un prélèvement sur cartouche de 2,4-dinitrophénylhydrazine (DNPH), qui est analysée par chromatographie en phase liquide après extraction. Cette méthode nécessite un équipement lourd et une étape en laboratoire est nécessaire. La société Ethera développe et commercialise des capteurs spécifiques pour la détection et la mesure du formaldéhyde avec des échantillonneurs passifs ou actifs. Ce capteur est basé sur des matrices nanoporeuses contenant du Fluoral-P (4-amino-3-pentène-2-one), qui réagit sélectivement avec le formaldéhyde pour produire un composé coloré de la 3,5-diacétyl-1,4-dihydrolutidine (DDL). La DDL est détectée à 420nm par lecture optique et la différence de densité optique mesurée avant et après l'exposition du capteur est directement proportionnelle à la concentration en formaldéhyde dans l'air intérieur. Le but de cette thèse est d'améliorer les performances des échantillonneurs passifs. Les différentes phases du développement des échantillonneurs passifs sont étudiées (conception, évaluation en chambre d’exposition) avec différentes approches et méthodologies. Deux axes d'étude sont considérés: une approche théorique et des essais en laboratoire. Une approche théorique a été mise en œuvre pour optimiser un échantillonneur passif ou dimensionner un nouveau préleveur. Les tests de laboratoire ont permis d'évaluer les paramètres métrologiques des échantillonneurs passifs (limite de détection, sensibilité, répétabilité, linéarité ...) et les effets des facteurs d'exposition (température, humidité relative, concentration). / Since 2001 and the creation of a French Indoor Air Quality Observatory (OQAI), indoor air quality has become a major public health issue. It is the subject of a regulatory framework that continues to evolve in recent years. Two recent decrees, in France, foresee the implementation of the labeling of building materials according to their emissions of volatile organic compounds (VOCs) (decree n°2011-321, 23/03/2011) and the survey of air concentration of two pollutants (benzene and formaldehyde) with guide values in public buildings (n°2011-1728, 2/12/2012). Today, the analytical method used to measure formaldehyde concentration in air consists in a 2,4-dinitrophenylhydrazine (DNPH) sampling cartridge which is analyzed by liquid chromatography after solvent extraction. This method is time consuming, expensive and complicated to perform. The company Ethera develops and markets specific, sensitive sensors for detection and measurement of formaldehyde with passive or active samplers. This sensor is based on a nanoporous matrix containing Fluoral-P (4-amino-3-penten-2-one), which selectively reacts with formaldehyde to produce a colored compound the 3,5-diacetyl-1,4-dihydrolutidine (DDL). DDL is detected at 420nm by optical reading and the difference of the optical density measured before and after exposition of the sensor is directly proportional to the concentration of formaldehyde in air. The purpose of this thesis is to improve the performance of passive samplers. The different phases of the development of passive samplers are studied (design, evaluation in environmental chamber) with different approaches and methodologies. In fact, two axis of study are considered: a theoretical approach and laboratory tests. Theoretical approach will be implemented to optimize a passive sampler or for sizing a new one based on the study of theoretical sampling rates. Laboratory tests will allow to assess metrological parameters of passive samplers (detection limit, sensitivity, repeatability, linearity…) and to estimate effects of exposure factors (temperature, relative humidity, concentration levels …).
|
4 |
Design And Experimental Testing Of An Adsorbent Bed For A Thermal Wave Adsorption Cooling CycleCaglar, Ahmet 01 September 2012 (has links) (PDF)
Poor heat and mass transfer inside the adsorbent bed of thermal wave adsorption cooling cycles cause low system performance and is an important problem in the adsorbent bed design. In this thesis, a new adsorbent bed is designed, constructed and tested to increase the heat and mass transfer in the adsorbent bed. The adsorbent bed is constructed from a finned tube in order to enhance the heat transfer. Additionally, the finned bed geometry is theoretically modeled and the model is solved time dependently by using Comsol Multiphysics software program. The distributions of dependent variables, i.e. temperature, pressure and amount adsorbed, are simulated and plotted in Comsol Multiphysics. In the model, the dependent variables are computed by solving the energy, mass and momentum transfer equations in a coupled way and their variations are investigated two-dimensionally. The results are presented with multicolored plots in a 2-D domain. Furthermore, a parametric study is carried out for determining factors that enhance the heat and mass transfer inside the adsorbent bed. In this parametric study, the effects of several design and operational parameters on the dependent variables are investigated. In the experimental study, the finned tube is tested using natural zeolite-water and silica gel-water working pairs. Temperature, pressure and amount adsorbed variations inside the adsorbent bed at various operating conditions are investigated. After that, a second adsorbent bed with a larger size is constructed and tested. The effect of the particle diameter of the adsorbent is also investigated. The experimental and theoretical results are compared.
|
5 |
Contribution à l'étude des transferts de matière gaz-liquide en présence de réactions chimiques / Contribution to the gas-liquid mass transfer study coupled with chemical reactionsWylock, Christophe 29 September 2009 (has links)
Le bicarbonate de soude raffiné, produit industriellement par la société Solvay, est fabriqué dans des colonnes à bulles de grande taille, appelées les colonnes BIR.<p>Dans ces colonnes, une phase gazeuse contenant un mélange d’air et dioxyde de carbone (CO2) est dispersée sous forme de bulles dans une solution aqueuse de carbonate et de bicarbonate de sodium (respectivement Na2CO3 et NaHCO3). Cette dispersion donne lieu à un transfert de CO2 des bulles vers la phase liquide. Au sein des colonnes, la phase gazeuse se répartit dans deux populations de bulles :des petites bulles (diamètre de quelques mm) et des grandes bulles (diamètre de quelques cm). Le transfert bulle-liquide de CO2 est couplé à des réactions chimiques prenant place en phase liquide, qui conduisent à la conversion du Na2CO3 en NaHCO3. Une fois la concentration de saturation dépassée le NaHCO3 précipite sous forme de cristaux et un mélange liquide-solide est recueilli à la sortie de ces colonnes.<p>Ce travail, réalisé en collaboration avec la société Solvay, porte sur l’étude et la modélisation mathématique des phénomènes de transfert de matière entre phases, couplés à des réactions chimiques, prenant place au sein d’une colonne BIR. L’association d’études sur des colonnes à bulles à l’échelle industrielle ou réduite (pilote) et d’études plus fondamentales sur des dispositifs de laboratoire permet de développer une meilleure compréhension du fonctionnement des colonnes BIR et d’en construire un modèle mathématique détaillé.<p>L’objectif appliqué de ce travail est la mise au point d’un modèle mathématique complet et opérationnel d’une colonne BIR. Cet objectif est supporté par trois blocs de travail, dans lesquels différents outils sont développés et exploités.<p><p>Le premier bloc est consacré à la modélisation mathématique du transfert bulle-liquide de CO2 dans une solution aqueuse de NaHCO3 et de Na2CO3. Ce transfert est couplé à des réactions chimiques en phase liquide qui influencent sa vitesse. Dans un premier temps, des modèles sont développés selon des approches unidimensionnelles classiquement rencontrées dans la littérature. Ces approches passent par une idéalisation de l’écoulement du liquide autour des bulles. Une expression simplifiée de la vitesse du transfert bulle-liquide de CO2, est également développée et validée pour le modèle de colonne BIR.<p>Dans un second temps, une modélisation complète des phénomènes de transport (convection et diffusion), couplés à des réactions chimiques, est réalisée en suivant une approche bidimensionnelle axisymétrique. L’influence de la vitesse de réactions sur la vitesse de transfert est étudiée et les résultats des deux approches sont également comparés.<p><p>Le deuxième bloc est consacré à l’étude expérimentale du transfert gaz-liquide de CO2 dans des solutions aqueuses de NaHCO3 et de Na2CO3. A cette fin, un dispositif expérimental est développé et présenté. Du CO2 est mis en contact avec des solutions aqueuses de NaHCO3 et de Na2CO3 dans une cellule transparente. Les phénomènes provoqués en phase liquide par le transfert de CO2 sont observés à l’aide d’un interféromètre de Mach-Zehnder.<p>Les résultats expérimentaux sont comparés à des résultats de simulation obtenus avec un des modèles unidimensionnels développés dans le premier bloc. De cette comparaison, il apparaît qu’une mauvaise estimation de la valeur de certains paramètres physico-chimiques apparaissant dans les équations de ce modèle conduit à des écarts significatifs entre les grandeurs observées expérimentalement et les grandeurs estimées par simulation des équations du modèle.<p>C’est pourquoi une méthode d’estimation paramétrique est également développée afin d’identifier les valeurs numériques de ces paramètres physico-chimiques sur base des résultats expérimentaux. Ces dernières sont également discutées.<p><p>Dans le troisième bloc, nous apportons une contribution à l’étude des cinétiques de précipitation du NaHCO3 dans un cristallisoir à cuve agitée. Cette partie du travail est réalisée en collaboration avec Vanessa Gutierrez (du service Matières et Matériaux de l’ULB).<p>Nous contribuons à cette étude par le développement de trois outils :une table de calcul Excel permettant de synthétiser les résultats expérimentaux, un ensemble de simulations de l’écoulement au sein du cristallisoir par mécanique des fluides numérique et une nouvelle méthode d’extraction des cinétiques de précipitation du NaHCO3 à partir des résultats expérimentaux. Ces trois outils sont également utilisés de façon combinée pour estimer les influences de la fraction massique de solide et de l’agitation sur la cinétique de germination secondaire du NaHCO3.<p><p>Enfin, la synthèse de l’ensemble des résultats de ces études est réalisée. Le résultat final est le développement d’un modèle mathématique complet et opérationnel des colonnes BIR. Ce modèle est développé en suivant l’approche de modélisation en compartiments, développée au cours du travail de Benoît Haut. Ce modèle synthétise les trois blocs d’études réalisées dans ce travail, ainsi que les travaux d’Aurélie Larcy (du service Transferts, Interfaces et Procédés de l’ULB) et de Vanessa Gutierrez. Les équations modélisant les différents phénomènes sont présentées, ainsi que la méthode utilisée pour résoudre ces équations. Des simulations des équations du modèle sont réalisées et discutées. Les résultats de simulation sont également comparés à des mesures effectuées sur une colonne BIR. Un accord raisonnable est observé.<p>A l’issue de ce travail, nous disposons donc d’un modèle opérationnel de colonne BIR. Bien que ce modèle doive encore être optimisé et validé, il peut déjà être utilisé pour étudier l’effet des caractéristiques géométriques des colonnes BIR et des conditions appliquées à ces colonnes sur le comportement des simulations des équations du modèle et pour identifier des tendances.<p>//<p>The refined sodium bicarbonate is produced by the Solvay company using large size bubble columns, called the BIR columns.<p>In these columns, a gaseous phase containing an air-carbon dioxyde mixture (CO2) is dispersed under the form of bubbles in an aqueous solution of sodium carbonate and sodium bicarbonate (Na2CO3 and NaHCO3, respectively). This dispersion leads to a CO2 transfer from the bubbles to the liquid phase. Inside these columns, the gaseous phase is distributed in two bubbles populations :small bubbles (a few mm of diameter) and large bubbles (a few cm of diameter).<p>The bubble-liquid CO2 transfer is coupled with chemical reactions taking places in the liquid phase that leads to the conversion of Na2CO3 to NaHCO3. When the solution is supersaturated in NaHCO3, the NaHCO3 precipitates under the form of crystals and a liquid-solid mixture is extracted at the outlet of the BIR columns.<p>This work, realized in collaboration with Solvay, aims to study and to model mathematically the mass transport phenomena between the phases, coupled with chemical reactions, taking places inside a BIR column. Study of bubble columns at the industrial and the pilot scale is combined to a more fundamental study at laboratory scale to improve the understanding of the BIR columns functioning and to develop a detailed mathematical modeling.<p>The applied objective of this work is to develop a complete and operational mathematical modeling of a BIR column. This objective is supported by three blocks of work. In each block, several tools are developed and used.<p><p>The first block is devoted to the mathematical modeling of the bubble-liquid CO2 transfer in an NaHCO3 and Na2CO3 aqueous solution. This transfer is coupled with chemical reactions in liquid phase, which affect the transfer rate.<p>In a first time, mathematical models are developed following the classical one-dimensional approaches of the literature. These approaches idealize the liquid flow around the bubbles. A simplified expression of the bubble-liquid CO2 transfer rate is equally developed and validated for the BIR column model.<p>In a second time, a complete modeling of the transport phenomena (convection and diffusion) coupled with chemical reactions is developed, following an axisymmetrical twodimensional approach. The chemical reaction rate influence on the bubble-liquid transfer rate is studied and the results of the two approaches are then compared.<p><p>The second block is devoted to the experimental study of the gas-liquid CO2 transfer to NaHCO3 and Na2CO3 aqueous solutions. An experimental set-up is developed and presented. CO2 is put in contact with NaHCO3 and Na2CO3 aqueous solutions in a transparent cell. The phenomena induced in liquid phase by the CO2 transfer are observed using a Mach-Zehnder interferometer.<p>The experimental results are compared to simulation results that are obtained using one of the one-dimensional model developed in the first block. From this comparison, it appears that a wrong estimation of some physico-chemical parameter values leads to significative differences between the experimentally observed quantities and those estimated by simulation of the model equations. Therefore, a parametric estimation method is developed in order to estimate those parameters numerical values from the experimental results. The found values are then discussed.<p><p>In the third block is presented a contribution to the NaHCO3 precipitation kinetic study in a stirred-tank crystallizer. This part of the work is realized in collaboration with Vanessa Gutierrez (Chemicals and Materials Department of ULB).<p>Three tools are developed :tables in Excel sheet to synthetize the experimental results, a set of simulations of the flow inside the crystallizer by Computational Fluid Dynamic (CFD) and a new method to extract the NaHCO3 precipitation kinetics from the experimental measurements. These three tools are combined to estimate the influences of the solid mass fraction and the flow on the NaHCO3 secondary nucleation rate.<p><p>Finally, the synthesis of all these results is realized. The final result is the development of a complete and operational mathematical model of BIR columns. This model is developed following the compartmental modeling approach, developed in the PhD thesis of Benoît Haut. This model synthetizes the three block of study realized in this work and the studies of Aurélie Larcy (Transfers, Interfaces and Processes Department of ULB) and those of Vanessa Gutierrez. The equations modeling the phenomena taking place in a BIR column are presented as the used method to solve these equations. The equations of the model are simulated and the results are discussed. The results are equally compared to experimental measurement realized on a BIR column. A reasonable agreement is observed.<p>At the end of this work, an operational model of a BIR column is thus developed. Although this model have to be optimized and validated, it can already be used to study the influences of the geometrical characteristics of the BIR columns and of the conditions applied to these columns on the behaviour of the model equation simulations and to identity tendencies. / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished
|
Page generated in 0.1272 seconds