• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Microdureza da dentina radicular adjacente a materiais restauradores contendo flúor após desafios erosivos: Estudo in situ / ex vivo / Effect of different restorative materials on root dentine erosion: an in situ /ex vivo study

Domiciano, Silvia Jorge 11 January 2008 (has links)
Este estudo foi realizado a fim de avaliar a microdureza da dentina radicular adjacente a materiais restauradores contendo fluoretos após desafios erosivos. Foi utilizado um delineamento crossover de duas fases de 4 dias consecutivos cada. Cento e doze fragmentos de dentina bovina foram obtidos, nos quais foi confeccionada uma cavidade padronizada no centro de cada um. Estas cavidades foram restauradas aleatoriamente com cimento de ionômero de vidro (Ketac-fil) ou resina composta (Filtek Z-250). Em seguida, os fragmentos restaurados foram distribuídos aleatoriamente entre os 14 voluntários, montados em aparelhos, cada um com 4 espécimes restaurados com o mesmo material. A partir do segundo dia, metade do aparelho, com dois espécimes, foi imersa em refrigerante de limão por 90 s, quatro vezes por dia, fora da boca por 3 dias. Após um intervalo de 3 dias, fragmentos restaurados com o material ainda não utilizado foram montados no aparelho e foi iniciada a segunda fase do experimento. Após os desafios erosivos, foram realizadas as medidas da microdureza da dentina adjacente às restaurações. Independente do material empregado, os espécimes erodidos apresentaram menores valores de microdureza (p<0.0001). Com relação aos materiais restauradores, foi verificado que a dentina, nas condições deste estudo, apresentou maiores valores de microdureza quando restaurada com cimento de ionômero de vidro (p<0.0001). Sendo assim, podemos concluir que o cimento de ionômero de vidro diminui a progressão da erosão da dentina radicular adjacente à restauração. / This study sought to evaluate the microhardness of root dentine adjacent to fluoride-containing restorative materials after erosive challenge. A cross-over study was performed in two phases of 4 consecutive days each. One hundred and twelve bovine root dentine slabs were obtained, and standardized box-shaped cavities were prepared at center of each specimen. The prepared cavities were randomly restored with glass-ionomer cement or composite resin. The slabs were randomly assigned among 14 volunteers, which wore intraoral palatal device containing 4 restored root dentin slabs. Starting on the second day, half of the palatal acrylic devices were immersed extraorally in a lemonade-like carbonated soft drink for 90 seconds, four times daily for 3 days. After 3-day wash-out, dentine slabs restored with the alternative material were placed into palatal appliance and the volunteers started the second phase of this study. After erosive challenges, microhardness measurements were performed. Regardless of the restorative material employed, eroded specimens demonstrated lower microhardness value (p<0.0001). At any given dentine condition examined in this study, dentine restored with glass-ionomer cement showed higher microhardness values (p<0.0001). It may be concluded that the glass-ionomer cement decreases the progression of root dentine erosion at restoration margin.
2

Microdureza da dentina radicular adjacente a materiais restauradores contendo flúor após desafios erosivos: Estudo in situ / ex vivo / Effect of different restorative materials on root dentine erosion: an in situ /ex vivo study

Silvia Jorge Domiciano 11 January 2008 (has links)
Este estudo foi realizado a fim de avaliar a microdureza da dentina radicular adjacente a materiais restauradores contendo fluoretos após desafios erosivos. Foi utilizado um delineamento crossover de duas fases de 4 dias consecutivos cada. Cento e doze fragmentos de dentina bovina foram obtidos, nos quais foi confeccionada uma cavidade padronizada no centro de cada um. Estas cavidades foram restauradas aleatoriamente com cimento de ionômero de vidro (Ketac-fil) ou resina composta (Filtek Z-250). Em seguida, os fragmentos restaurados foram distribuídos aleatoriamente entre os 14 voluntários, montados em aparelhos, cada um com 4 espécimes restaurados com o mesmo material. A partir do segundo dia, metade do aparelho, com dois espécimes, foi imersa em refrigerante de limão por 90 s, quatro vezes por dia, fora da boca por 3 dias. Após um intervalo de 3 dias, fragmentos restaurados com o material ainda não utilizado foram montados no aparelho e foi iniciada a segunda fase do experimento. Após os desafios erosivos, foram realizadas as medidas da microdureza da dentina adjacente às restaurações. Independente do material empregado, os espécimes erodidos apresentaram menores valores de microdureza (p<0.0001). Com relação aos materiais restauradores, foi verificado que a dentina, nas condições deste estudo, apresentou maiores valores de microdureza quando restaurada com cimento de ionômero de vidro (p<0.0001). Sendo assim, podemos concluir que o cimento de ionômero de vidro diminui a progressão da erosão da dentina radicular adjacente à restauração. / This study sought to evaluate the microhardness of root dentine adjacent to fluoride-containing restorative materials after erosive challenge. A cross-over study was performed in two phases of 4 consecutive days each. One hundred and twelve bovine root dentine slabs were obtained, and standardized box-shaped cavities were prepared at center of each specimen. The prepared cavities were randomly restored with glass-ionomer cement or composite resin. The slabs were randomly assigned among 14 volunteers, which wore intraoral palatal device containing 4 restored root dentin slabs. Starting on the second day, half of the palatal acrylic devices were immersed extraorally in a lemonade-like carbonated soft drink for 90 seconds, four times daily for 3 days. After 3-day wash-out, dentine slabs restored with the alternative material were placed into palatal appliance and the volunteers started the second phase of this study. After erosive challenges, microhardness measurements were performed. Regardless of the restorative material employed, eroded specimens demonstrated lower microhardness value (p<0.0001). At any given dentine condition examined in this study, dentine restored with glass-ionomer cement showed higher microhardness values (p<0.0001). It may be concluded that the glass-ionomer cement decreases the progression of root dentine erosion at restoration margin.
3

Influência de técnicas de clareamento dental na microdureza superficial e alteração de cor de resinas compostas / Influence of bleaching techniques on the color change and surface microhardness of composites resins

Turrini Neto, Pedro 28 March 2008 (has links)
O presente trabalho tem por objetivo avaliar os efeitos do clareamento caseiro, com peróxido de carbamida 10%, e clínico, com peróxido de carbamida 37%, na microdureza e alteração de cor de duas resinas compostas (Z250 e Supreme). Foram confeccionados 100 espécimes, 60 para microdureza e 40 para alteração de cor, com 6mm de diâmetro e 2mm de espessura, em resina composta. A matriz foi preenchida em um único incremento e polimerizada por 20s. Na seqüência os espécimes foram polidos com lixas #1200 e com pasta diamantada. Realizou-se então a primeira medição de dureza e cor dos espécimes. A seguir, para o estudo de cor foi realizada o manchamento com café durante 7 dias e então realizado uma segunda medição da cor. Os espécimes foram divididos aleatoriamente em 3 grupos para microdureza e 2 grupos para cor (n=10) de acordo com o tratamento clareador. Para o clareamento clínico foram realizadas três sessões com intervalo de 7 dias entre elas. Para o clareamento caseiro foram feitas 4h de aplicações diárias durante 14 dias. Nos intervalos entre os procedimentos de clareamentos os espécimes foram armazenados em saliva artificial a 37ºC. Após o final do clareamento nova medição de microdureza e cor foram realizadas. Os dados obtidos foram submetidos ANOVA e Fisher (p<0,05). Para a microdureza os dados revelaram que a Z250, o tratamento clínico e antes do tratamento apresentaram valores estatisticamente superiores aos demais. Na análise da cor pode-se observar que &Delta;E e &Delta;b apresentaram diferenças significativas para os fatores material, tratamento e entre os grupos, para o &Delta;L a Z250 apresentou-se mais escura que a Supreme. Na comparação do clareamento como o padrão observou-se não haver diferenças significativas entre o &Delta;E e &Delta;L para nenhum fator, porém diferenças significativas apresentaram-se para o &Delta;a e &Delta;b para os fatores material e tratamento. Pode-se concluir que os dois métodos de clareamento foram eficientes em clarear os espécimes a valores próximos ao padrão, sendo mais efetivo o clareamento clínico sem alterar a dureza dos materiais e tendo a Supreme apresentado melhor comportamento que a Z250 no retorno da coloração inicial. / The aim of this study was to evaluate the effects of home bleaching (10% carbamide peroxide) and in office bleaching (37% carbamide peroxide) on the color alteration and microhardness of two composite resins (Z250 and Supreme). For this purpose, it was prepared 100 specimens of resin, 60 for microhardness and 40 for color alteration, with 6mm diameter X 2mm thickness. The matrix was filled in a single increment and the resin was light cured for 20s. Specimens were polished after 24 hours with sandpaper #1200 and diamond paste. In this moment, the first color measurements (standard) and also microhardness measurements were realized. After, in the color study specimens were immersed in coffee for a seven days period, subsequently, a second color measurement was realized. Specimens were randomly divided in three groups for microhardness and two groups for color alteration (n=10) according to bleaching treatment. For the office bleaching were realized in 3 sessions with interval of 7 days among them, and every session were realized 3 applications of the bleach agent for 20 min. For the home bleaching, it was done daily applications with 4h duration by 14 days. Specimens were kept in artificial saliva at 37ºC ± 1ºC during intervals between the bleaching proceedings. A new microhardness and color measurements were realized in the end of the bleaching cycle. Data were submitted to ANOVA and Fisher test (p<0.05) and in relation to microhardness showed that Z250 (material), in office bleaching (treatment) and before bleaching (time) presented higher statistically significant values comparing to the others results. For color alteration showed that &Delta;E and &Delta;b were statistically significant differences for the following factors: material, treatment and interactions, for &Delta;L values, Z250 presented darker than Supreme. In the comparison of bleaching with the standard values, it was not observed statistically significant difference between &Delta;E e &Delta;L for all factors; however, it was observed significant difference to &Delta;a and &Delta;b for the factors material and treatment. It can be concluded that both methods of bleaching were efficient in brightness specimens to values near from standard. Furthermore, in office bleaching was more effective without change materials micro hardness and Supreme presented better behavior than Z250 in relation to return to initial color.
4

Influência de técnicas de clareamento dental na microdureza superficial e alteração de cor de resinas compostas / Influence of bleaching techniques on the color change and surface microhardness of composites resins

Pedro Turrini Neto 28 March 2008 (has links)
O presente trabalho tem por objetivo avaliar os efeitos do clareamento caseiro, com peróxido de carbamida 10%, e clínico, com peróxido de carbamida 37%, na microdureza e alteração de cor de duas resinas compostas (Z250 e Supreme). Foram confeccionados 100 espécimes, 60 para microdureza e 40 para alteração de cor, com 6mm de diâmetro e 2mm de espessura, em resina composta. A matriz foi preenchida em um único incremento e polimerizada por 20s. Na seqüência os espécimes foram polidos com lixas #1200 e com pasta diamantada. Realizou-se então a primeira medição de dureza e cor dos espécimes. A seguir, para o estudo de cor foi realizada o manchamento com café durante 7 dias e então realizado uma segunda medição da cor. Os espécimes foram divididos aleatoriamente em 3 grupos para microdureza e 2 grupos para cor (n=10) de acordo com o tratamento clareador. Para o clareamento clínico foram realizadas três sessões com intervalo de 7 dias entre elas. Para o clareamento caseiro foram feitas 4h de aplicações diárias durante 14 dias. Nos intervalos entre os procedimentos de clareamentos os espécimes foram armazenados em saliva artificial a 37ºC. Após o final do clareamento nova medição de microdureza e cor foram realizadas. Os dados obtidos foram submetidos ANOVA e Fisher (p<0,05). Para a microdureza os dados revelaram que a Z250, o tratamento clínico e antes do tratamento apresentaram valores estatisticamente superiores aos demais. Na análise da cor pode-se observar que &Delta;E e &Delta;b apresentaram diferenças significativas para os fatores material, tratamento e entre os grupos, para o &Delta;L a Z250 apresentou-se mais escura que a Supreme. Na comparação do clareamento como o padrão observou-se não haver diferenças significativas entre o &Delta;E e &Delta;L para nenhum fator, porém diferenças significativas apresentaram-se para o &Delta;a e &Delta;b para os fatores material e tratamento. Pode-se concluir que os dois métodos de clareamento foram eficientes em clarear os espécimes a valores próximos ao padrão, sendo mais efetivo o clareamento clínico sem alterar a dureza dos materiais e tendo a Supreme apresentado melhor comportamento que a Z250 no retorno da coloração inicial. / The aim of this study was to evaluate the effects of home bleaching (10% carbamide peroxide) and in office bleaching (37% carbamide peroxide) on the color alteration and microhardness of two composite resins (Z250 and Supreme). For this purpose, it was prepared 100 specimens of resin, 60 for microhardness and 40 for color alteration, with 6mm diameter X 2mm thickness. The matrix was filled in a single increment and the resin was light cured for 20s. Specimens were polished after 24 hours with sandpaper #1200 and diamond paste. In this moment, the first color measurements (standard) and also microhardness measurements were realized. After, in the color study specimens were immersed in coffee for a seven days period, subsequently, a second color measurement was realized. Specimens were randomly divided in three groups for microhardness and two groups for color alteration (n=10) according to bleaching treatment. For the office bleaching were realized in 3 sessions with interval of 7 days among them, and every session were realized 3 applications of the bleach agent for 20 min. For the home bleaching, it was done daily applications with 4h duration by 14 days. Specimens were kept in artificial saliva at 37ºC ± 1ºC during intervals between the bleaching proceedings. A new microhardness and color measurements were realized in the end of the bleaching cycle. Data were submitted to ANOVA and Fisher test (p<0.05) and in relation to microhardness showed that Z250 (material), in office bleaching (treatment) and before bleaching (time) presented higher statistically significant values comparing to the others results. For color alteration showed that &Delta;E and &Delta;b were statistically significant differences for the following factors: material, treatment and interactions, for &Delta;L values, Z250 presented darker than Supreme. In the comparison of bleaching with the standard values, it was not observed statistically significant difference between &Delta;E e &Delta;L for all factors; however, it was observed significant difference to &Delta;a and &Delta;b for the factors material and treatment. It can be concluded that both methods of bleaching were efficient in brightness specimens to values near from standard. Furthermore, in office bleaching was more effective without change materials micro hardness and Supreme presented better behavior than Z250 in relation to return to initial color.
5

Comparação in vitro do desgaste dental em função da dureza de três diferentes tipos de materiais antagonistas / In vitro comparison of dental wear according to the hardness of three different antagonist materials

Ana Paula Cunha da Silva Costa 08 October 2010 (has links)
O objetivo deste estudo foi comparar in vitro o desgaste dental de pré-molares (PM) e molares (M) e sua relação com o valor de dureza Vickers dos materiais utilizados como antagonistas em uma máquina de abrasão simulada para provocar o desgaste nos dentes testados. Os materiais antagonistas utilizados foram VeraBond II (liga de Ni-Cr), Solidex (resina composta) e IPS Empress 2 (cerâmica). Para cada ensaio de dureza, foram preparados seis corpos-de-prova de cada material, os quais foram polidos sob refrigeração, com ciclo de 20 min para cada granulação. Num microdurômetro (HMV-2), foram realizadas três mossas por quadrante, cada uma sob carga de 19,614 N por 30 s, totalizando 12 mossas de base quadrada com ângulo de 136 entre os planos. O teste de abrasão foi realizado numa máquina simuladora de abrasão, freqüência de 265 ciclos/min e 4,4 Hz, com um percurso do antagonista de 10 mm à velocidade de 88 mm/s. Cada dente foi testado em oposição a um antagonista (foram 6 pares dente/material para cada grupo), em água deionizada, sob carga de 5 N, por 150 min, num total de 39.750 ciclos. Foram utilizados dezenove dentes 1 pré-molares, dezenove 3 molares e confeccionados doze antagonistas em cada material em forma de pastilha. Cada grupo de seis dentes foi testado em oposição a seis antagonistas do mesmo material. Ademais, um dente 1 pré-molar (PM) e um dente 3 molar (M) foram testados em oposição ao Plexiglass. Com relação ao desgaste do esmalte dentário (PM+M) segundo o material antagonista, o teste de Kruskal-Wallis evidenciou diferença significativa com p-valor < 0,001 e o teste de Mann-Whitney evidenciou diferença significativa nas comparações PM+M/resina X PM+M/metal (p-valor < 0,001), PM+M/resina X PM+M/cerâmica (p-valor < 0,001) e PM+M/metal X PM+M/cerâmica (p-valor = 0,002). A análise isolada, considerando pré-molares e molares separadamente, encontrou diferença significativa em relação ao desgaste do esmalte dentário no teste de Kruskall-Wallis, porém não detectou diferença significativa no teste de comparação múltipla Mann-Whitney quando comparou o desgaste sofrido pelo PM/metal em relação ao PM/cerâmica. Em relação à dureza Vickers detectou-se diferença significativa da dureza dos materiais no teste de Kruskall-Wallis (p-valor < 0,001) e também no teste de Mann-Whitney nas comparações múltiplas com p-valor = 0,002. Comparando-se a dureza com a perfilometria, observou-se uma correlação estatisticamente significativa (p &#8804; 0,05) na correlação negativa (&#961;= -0,829) entre a dureza do metal como material antagonista e o desgaste do esmalte dentário do dente molar. Os resultados sugeriram que todo material restaurador indireto estudado causou desgaste ao esmalte dentário quando submetido a forças de simulação de abrasão com carga. Embora tenha sido observada correlação entre dureza e resistência à abrasão, essa correlação foi pouco significativa. / The objective of this study was to compare the dental wear of pre-molars (PM) and molars (M) in vitro, and the relationship between dental wear and the Vickers hardness values of the materials used as antagonists in a machine simulating abrasion to produce wear on the teeth tested. The materials used as antagonists were VeraBond II (Ni-Cr alloy), Solidex (composite resin) and IPS Empress 2 (ceramic). Six specimens of each material were prepared for each hardness trial. The specimens were polished under refrigeration, with a 20-min cycle for each grit number. Three dents per quadrant were made in a microhardness tester (HMV-2), under a 19.614 N load for 30 s, for a total of 12 square-base dents with a 136 angle between planes. The abrasion test was performed in an abrasion-simulating machine set to a frequency of 265 cycles/min and 4,4 Hz. The course of the antagonist was 10 mm, at a speed of 88 mm/s. Each tooth was tested against an antagonist material (6 tooth/material pairs per group), in deionized water, under a 5 N load, for 150 min, for a total of 39,750 cycles. Nineteen first pre-molars (PM) and 19 third molars (M) were used, and 12 antagonistic discs were made in each material, for the tests. Each group of six teeth was tested against six antagonists of the same material. Additionally, 1 first pre-molar (PM) and one third molar (M) were tested against Plexiglass. Regarding the dental enamel wear on pre-molars and molars (PM+M) according to the antagonist material, the Kruskal-Wallis test revealed significant differences (p-value < 0.001) and the Mann-Whitney test also revealed significant differences for the following comparisons: PM+M/resin versus PM+M/metal (p-value < 0.001), PM+M/resin versus PM+M/ceramic (p-value < 0.001), and PM+M/metal versus PM+M/ceramic (p-value = 0.002). An analysis conducted with the Kruskall-Wallis test, considering pre-molars (PM) and molars (M) separately, found significant differences in relation to dental enamel wear (PM+M). However, when the multiple-comparison Mann-Whitney test was used, no significant difference was detected between the wear produced in the pre-molar/metal pair and that produced in the pre-molar/ceramic pair. Regarding Vickers hardness, both the Kruskall-Wallis test (p-value < 0.001) and Mann-Whitneys multiple-comparisons test (p-value = 0.002) revealed significant differences between materials. When hardness was compared with the profilometry data, a significant negative correlation was observed (p &#8804; 0.05, &#961; = -0.829) between the hardness of the metal as an antagonist material and the dental enamel wear of the molar tooth. The results suggested that all the indirect restorative materials tested caused wear of the dental enamel when submitted to the forces of simulated abrasion with load. Although a correlation was observed between hardness and resistance to abrasion, this correlation was hardly significant.
6

Comparação in vitro do desgaste dental em função da dureza de três diferentes tipos de materiais antagonistas / In vitro comparison of dental wear according to the hardness of three different antagonist materials

Ana Paula Cunha da Silva Costa 08 October 2010 (has links)
O objetivo deste estudo foi comparar in vitro o desgaste dental de pré-molares (PM) e molares (M) e sua relação com o valor de dureza Vickers dos materiais utilizados como antagonistas em uma máquina de abrasão simulada para provocar o desgaste nos dentes testados. Os materiais antagonistas utilizados foram VeraBond II (liga de Ni-Cr), Solidex (resina composta) e IPS Empress 2 (cerâmica). Para cada ensaio de dureza, foram preparados seis corpos-de-prova de cada material, os quais foram polidos sob refrigeração, com ciclo de 20 min para cada granulação. Num microdurômetro (HMV-2), foram realizadas três mossas por quadrante, cada uma sob carga de 19,614 N por 30 s, totalizando 12 mossas de base quadrada com ângulo de 136 entre os planos. O teste de abrasão foi realizado numa máquina simuladora de abrasão, freqüência de 265 ciclos/min e 4,4 Hz, com um percurso do antagonista de 10 mm à velocidade de 88 mm/s. Cada dente foi testado em oposição a um antagonista (foram 6 pares dente/material para cada grupo), em água deionizada, sob carga de 5 N, por 150 min, num total de 39.750 ciclos. Foram utilizados dezenove dentes 1 pré-molares, dezenove 3 molares e confeccionados doze antagonistas em cada material em forma de pastilha. Cada grupo de seis dentes foi testado em oposição a seis antagonistas do mesmo material. Ademais, um dente 1 pré-molar (PM) e um dente 3 molar (M) foram testados em oposição ao Plexiglass. Com relação ao desgaste do esmalte dentário (PM+M) segundo o material antagonista, o teste de Kruskal-Wallis evidenciou diferença significativa com p-valor < 0,001 e o teste de Mann-Whitney evidenciou diferença significativa nas comparações PM+M/resina X PM+M/metal (p-valor < 0,001), PM+M/resina X PM+M/cerâmica (p-valor < 0,001) e PM+M/metal X PM+M/cerâmica (p-valor = 0,002). A análise isolada, considerando pré-molares e molares separadamente, encontrou diferença significativa em relação ao desgaste do esmalte dentário no teste de Kruskall-Wallis, porém não detectou diferença significativa no teste de comparação múltipla Mann-Whitney quando comparou o desgaste sofrido pelo PM/metal em relação ao PM/cerâmica. Em relação à dureza Vickers detectou-se diferença significativa da dureza dos materiais no teste de Kruskall-Wallis (p-valor < 0,001) e também no teste de Mann-Whitney nas comparações múltiplas com p-valor = 0,002. Comparando-se a dureza com a perfilometria, observou-se uma correlação estatisticamente significativa (p &#8804; 0,05) na correlação negativa (&#961;= -0,829) entre a dureza do metal como material antagonista e o desgaste do esmalte dentário do dente molar. Os resultados sugeriram que todo material restaurador indireto estudado causou desgaste ao esmalte dentário quando submetido a forças de simulação de abrasão com carga. Embora tenha sido observada correlação entre dureza e resistência à abrasão, essa correlação foi pouco significativa. / The objective of this study was to compare the dental wear of pre-molars (PM) and molars (M) in vitro, and the relationship between dental wear and the Vickers hardness values of the materials used as antagonists in a machine simulating abrasion to produce wear on the teeth tested. The materials used as antagonists were VeraBond II (Ni-Cr alloy), Solidex (composite resin) and IPS Empress 2 (ceramic). Six specimens of each material were prepared for each hardness trial. The specimens were polished under refrigeration, with a 20-min cycle for each grit number. Three dents per quadrant were made in a microhardness tester (HMV-2), under a 19.614 N load for 30 s, for a total of 12 square-base dents with a 136 angle between planes. The abrasion test was performed in an abrasion-simulating machine set to a frequency of 265 cycles/min and 4,4 Hz. The course of the antagonist was 10 mm, at a speed of 88 mm/s. Each tooth was tested against an antagonist material (6 tooth/material pairs per group), in deionized water, under a 5 N load, for 150 min, for a total of 39,750 cycles. Nineteen first pre-molars (PM) and 19 third molars (M) were used, and 12 antagonistic discs were made in each material, for the tests. Each group of six teeth was tested against six antagonists of the same material. Additionally, 1 first pre-molar (PM) and one third molar (M) were tested against Plexiglass. Regarding the dental enamel wear on pre-molars and molars (PM+M) according to the antagonist material, the Kruskal-Wallis test revealed significant differences (p-value < 0.001) and the Mann-Whitney test also revealed significant differences for the following comparisons: PM+M/resin versus PM+M/metal (p-value < 0.001), PM+M/resin versus PM+M/ceramic (p-value < 0.001), and PM+M/metal versus PM+M/ceramic (p-value = 0.002). An analysis conducted with the Kruskall-Wallis test, considering pre-molars (PM) and molars (M) separately, found significant differences in relation to dental enamel wear (PM+M). However, when the multiple-comparison Mann-Whitney test was used, no significant difference was detected between the wear produced in the pre-molar/metal pair and that produced in the pre-molar/ceramic pair. Regarding Vickers hardness, both the Kruskall-Wallis test (p-value < 0.001) and Mann-Whitneys multiple-comparisons test (p-value = 0.002) revealed significant differences between materials. When hardness was compared with the profilometry data, a significant negative correlation was observed (p &#8804; 0.05, &#961; = -0.829) between the hardness of the metal as an antagonist material and the dental enamel wear of the molar tooth. The results suggested that all the indirect restorative materials tested caused wear of the dental enamel when submitted to the forces of simulated abrasion with load. Although a correlation was observed between hardness and resistance to abrasion, this correlation was hardly significant.

Page generated in 0.0871 seconds