Influência de técnicas de clareamento dental na microdureza superficial e alteração de cor de resinas compostas / Influence of bleaching techniques on the color change and surface microhardness of composites resins

Turrini Neto, Pedro 28 March 2008 (has links)
O presente trabalho tem por objetivo avaliar os efeitos do clareamento caseiro, com peróxido de carbamida 10%, e clínico, com peróxido de carbamida 37%, na microdureza e alteração de cor de duas resinas compostas (Z250 e Supreme). Foram confeccionados 100 espécimes, 60 para microdureza e 40 para alteração de cor, com 6mm de diâmetro e 2mm de espessura, em resina composta. A matriz foi preenchida em um único incremento e polimerizada por 20s. Na seqüência os espécimes foram polidos com lixas #1200 e com pasta diamantada. Realizou-se então a primeira medição de dureza e cor dos espécimes. A seguir, para o estudo de cor foi realizada o manchamento com café durante 7 dias e então realizado uma segunda medição da cor. Os espécimes foram divididos aleatoriamente em 3 grupos para microdureza e 2 grupos para cor (n=10) de acordo com o tratamento clareador. Para o clareamento clínico foram realizadas três sessões com intervalo de 7 dias entre elas. Para o clareamento caseiro foram feitas 4h de aplicações diárias durante 14 dias. Nos intervalos entre os procedimentos de clareamentos os espécimes foram armazenados em saliva artificial a 37ºC. Após o final do clareamento nova medição de microdureza e cor foram realizadas. Os dados obtidos foram submetidos ANOVA e Fisher (p<0,05). Para a microdureza os dados revelaram que a Z250, o tratamento clínico e antes do tratamento apresentaram valores estatisticamente superiores aos demais. Na análise da cor pode-se observar que &Delta;E e &Delta;b apresentaram diferenças significativas para os fatores material, tratamento e entre os grupos, para o &Delta;L a Z250 apresentou-se mais escura que a Supreme. Na comparação do clareamento como o padrão observou-se não haver diferenças significativas entre o &Delta;E e &Delta;L para nenhum fator, porém diferenças significativas apresentaram-se para o &Delta;a e &Delta;b para os fatores material e tratamento. Pode-se concluir que os dois métodos de clareamento foram eficientes em clarear os espécimes a valores próximos ao padrão, sendo mais efetivo o clareamento clínico sem alterar a dureza dos materiais e tendo a Supreme apresentado melhor comportamento que a Z250 no retorno da coloração inicial. / The aim of this study was to evaluate the effects of home bleaching (10% carbamide peroxide) and in office bleaching (37% carbamide peroxide) on the color alteration and microhardness of two composite resins (Z250 and Supreme). For this purpose, it was prepared 100 specimens of resin, 60 for microhardness and 40 for color alteration, with 6mm diameter X 2mm thickness. The matrix was filled in a single increment and the resin was light cured for 20s. Specimens were polished after 24 hours with sandpaper #1200 and diamond paste. In this moment, the first color measurements (standard) and also microhardness measurements were realized. After, in the color study specimens were immersed in coffee for a seven days period, subsequently, a second color measurement was realized. Specimens were randomly divided in three groups for microhardness and two groups for color alteration (n=10) according to bleaching treatment. For the office bleaching were realized in 3 sessions with interval of 7 days among them, and every session were realized 3 applications of the bleach agent for 20 min. For the home bleaching, it was done daily applications with 4h duration by 14 days. Specimens were kept in artificial saliva at 37ºC ± 1ºC during intervals between the bleaching proceedings. A new microhardness and color measurements were realized in the end of the bleaching cycle. Data were submitted to ANOVA and Fisher test (p<0.05) and in relation to microhardness showed that Z250 (material), in office bleaching (treatment) and before bleaching (time) presented higher statistically significant values comparing to the others results. For color alteration showed that &Delta;E and &Delta;b were statistically significant differences for the following factors: material, treatment and interactions, for &Delta;L values, Z250 presented darker than Supreme. In the comparison of bleaching with the standard values, it was not observed statistically significant difference between &Delta;E e &Delta;L for all factors; however, it was observed significant difference to &Delta;a and &Delta;b for the factors material and treatment. It can be concluded that both methods of bleaching were efficient in brightness specimens to values near from standard. Furthermore, in office bleaching was more effective without change materials micro hardness and Supreme presented better behavior than Z250 in relation to return to initial color.
2

Influência de técnicas de clareamento dental na microdureza superficial e alteração de cor de resinas compostas / Influence of bleaching techniques on the color change and surface microhardness of composites resins

Pedro Turrini Neto 28 March 2008 (has links)
O presente trabalho tem por objetivo avaliar os efeitos do clareamento caseiro, com peróxido de carbamida 10%, e clínico, com peróxido de carbamida 37%, na microdureza e alteração de cor de duas resinas compostas (Z250 e Supreme). Foram confeccionados 100 espécimes, 60 para microdureza e 40 para alteração de cor, com 6mm de diâmetro e 2mm de espessura, em resina composta. A matriz foi preenchida em um único incremento e polimerizada por 20s. Na seqüência os espécimes foram polidos com lixas #1200 e com pasta diamantada. Realizou-se então a primeira medição de dureza e cor dos espécimes. A seguir, para o estudo de cor foi realizada o manchamento com café durante 7 dias e então realizado uma segunda medição da cor. Os espécimes foram divididos aleatoriamente em 3 grupos para microdureza e 2 grupos para cor (n=10) de acordo com o tratamento clareador. Para o clareamento clínico foram realizadas três sessões com intervalo de 7 dias entre elas. Para o clareamento caseiro foram feitas 4h de aplicações diárias durante 14 dias. Nos intervalos entre os procedimentos de clareamentos os espécimes foram armazenados em saliva artificial a 37ºC. Após o final do clareamento nova medição de microdureza e cor foram realizadas. Os dados obtidos foram submetidos ANOVA e Fisher (p<0,05). Para a microdureza os dados revelaram que a Z250, o tratamento clínico e antes do tratamento apresentaram valores estatisticamente superiores aos demais. Na análise da cor pode-se observar que &Delta;E e &Delta;b apresentaram diferenças significativas para os fatores material, tratamento e entre os grupos, para o &Delta;L a Z250 apresentou-se mais escura que a Supreme. Na comparação do clareamento como o padrão observou-se não haver diferenças significativas entre o &Delta;E e &Delta;L para nenhum fator, porém diferenças significativas apresentaram-se para o &Delta;a e &Delta;b para os fatores material e tratamento. Pode-se concluir que os dois métodos de clareamento foram eficientes em clarear os espécimes a valores próximos ao padrão, sendo mais efetivo o clareamento clínico sem alterar a dureza dos materiais e tendo a Supreme apresentado melhor comportamento que a Z250 no retorno da coloração inicial. / The aim of this study was to evaluate the effects of home bleaching (10% carbamide peroxide) and in office bleaching (37% carbamide peroxide) on the color alteration and microhardness of two composite resins (Z250 and Supreme). For this purpose, it was prepared 100 specimens of resin, 60 for microhardness and 40 for color alteration, with 6mm diameter X 2mm thickness. The matrix was filled in a single increment and the resin was light cured for 20s. Specimens were polished after 24 hours with sandpaper #1200 and diamond paste. In this moment, the first color measurements (standard) and also microhardness measurements were realized. After, in the color study specimens were immersed in coffee for a seven days period, subsequently, a second color measurement was realized. Specimens were randomly divided in three groups for microhardness and two groups for color alteration (n=10) according to bleaching treatment. For the office bleaching were realized in 3 sessions with interval of 7 days among them, and every session were realized 3 applications of the bleach agent for 20 min. For the home bleaching, it was done daily applications with 4h duration by 14 days. Specimens were kept in artificial saliva at 37ºC ± 1ºC during intervals between the bleaching proceedings. A new microhardness and color measurements were realized in the end of the bleaching cycle. Data were submitted to ANOVA and Fisher test (p<0.05) and in relation to microhardness showed that Z250 (material), in office bleaching (treatment) and before bleaching (time) presented higher statistically significant values comparing to the others results. For color alteration showed that &Delta;E and &Delta;b were statistically significant differences for the following factors: material, treatment and interactions, for &Delta;L values, Z250 presented darker than Supreme. In the comparison of bleaching with the standard values, it was not observed statistically significant difference between &Delta;E e &Delta;L for all factors; however, it was observed significant difference to &Delta;a and &Delta;b for the factors material and treatment. It can be concluded that both methods of bleaching were efficient in brightness specimens to values near from standard. Furthermore, in office bleaching was more effective without change materials micro hardness and Supreme presented better behavior than Z250 in relation to return to initial color.
3

POLÍMERO ANTIMICROBIANO [QAMP] PARA INCORPORAÇÃO EM SISTEMA ADESIVO ODONTOLÓGICO: DESENVOLVIMENTO, CARACTERIZAÇÃO FÍSICO-QUÍMICA, AVALIAÇÃO DA PERMEABILIDADE VASCULAR E PROPRIEDADES MECÂNICAS / Antimicrobial polymer [QAMP] for incorporation into dental adhesive system: development, physicochemical characterization, evaluation of vascular permeability and mechanical properties

Pupo, Yasmine Mendes 17 May 2013 (has links)
Made available in DSpace on 2017-07-24T19:22:33Z (GMT). No. of bitstreams: 1 YASMINE M PUPO.pdf: 8545137 bytes, checksum: 4a5dc17fead5ffe17a36e9b6d7acb198 (MD5) Previous issue date: 2013-05-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The use of bioactive restorative materials, with the ability to reduce biofilm development and to present direct action against cariogenic microorganisms, has grown in the dental market and a trend in Adhesive Dentistry. This study aims to describe the synthesis, the characterization, the antimicrobial properties, the vascular permeability and the mechanical properties of the quaternary ammonium methacrylate polymer [QAMP], for incorporation into dental adhesive systems, in order to provide increase the durability of dental restorations. QAMP was obtained through chemical modification (alkylation) of a preformed polymer [Eudragit™ E100] and n-octyl bromide. The resulting product [QAMP] was characterized by infrared spectroscopy, Raman spectroscopy, Nuclear Magnetic Resonance spectroscopy, Visible spectrophotometry, X-ray diffraction and thermogravimetric analysis (TGA). The in vitro susceptibility testing against Streptococcus mutans of QAMP was performed prior and after incorporation into a commercial adhesive system (Clearfil™ SE Bond). Clearfil™ Protect Bond containing antimicrobial standard [MDPB] and Clearfil™ SE Bond without QAMP were used as positive and negative controls, respectively. To evaluate percentage of quaternary ammonium compound released from the experimental adhesive system a test was conducted, after intervals of predetermined time (1, 7, 14, 21 and 30 days). Spectroscopic data confirmed that QAMP was successfully acquired. Thermal analysis indicated that QAMP was heat-stable. The antimicrobial effect against the Streptococcus mutans, prior and after incorporation in a dental adhesive system, was proven. The release of the quaternary ammonium compound [QAMP], embedded in an adhesive system, was reduced when compared to the commercial product [MDPB]. Additionally, the effect of Clearfil™ SE Bond containing QAMP on the vascular permeability using Evans blue and laser!"!Doppler flowmetric methods was investigated in order to define the influence on the exudative phase of the inflammatory process in the subcutaneous tissue of rats. Results support that the adhesive system containing QAMP had lower effect on this phase indicating an adequate biocompatibility. In an attempt to determine the stability of QAMP, the bond strength of adhesive systems was evaluated in extracted human teeth through microtensile test immediately, after 6 and 12 months of storage of the stick-shaped specimens. The degree of conversion of the bonding interfaces was investigated, using micro-Raman spectroscopy, and in vitro by infrared Fourier Transform. Data obtained confirm that a self-etching adhesive system with the quaternary ammonium methacrylate polymer [QAMP] could produce the effective bond strength under in vitro conditions and stability of the degree of conversion in situ and in vitro. In the evaluation of mechanical properties, hardness and elastic modulus, slices of restored teeth were prepared with adhesives under study and were submitted to artificial methods for producing caries lesions during, pH-cycling or microbiological assay, for subsequent nanoindentation test performed in the region of the interface resin-dentin, leading to check the quality of the formed substrate. In general, Clearfil™ SE Bond containing QAMP provided better mechanical properties for the resin-dentin interface than other commercial selfetching adhesives after cariogenic challenges. These data include the development of quaternary ammonium polymers to provide additional benefits for dental adhesive systems widely used in dentistry. / A utilização de materiais restauradores bioativos, com capacidade de reduzir o desenvolvimento do biofilme e de apresentar ação direta contra microrganismos cariogênicos, tem crescido dentro do mercado odontológico, sendo uma tendência na Odontologia Adesiva. O presente estudo teve como objetivo descrever a síntese, a caracterização e as propriedades antimicrobianas, de permeabilidade vascular e mecânicas de um polímero metacrílico quaternário de amônio [QAMP], quando incorporado em sistemas adesivos odontológicos, com o propósito de aumentar a durabilidade das restaurações dentais. QAMP foi obtido por modificação química (alquilação) de um polímero pré-formado [Eudragit E100] com brometo de n-octila. O produto resultante [QAMP] foi caracterizado por espectroscopia na região do infravermelho, espectroscopia Raman, espectroscopia de Ressonância Magnética Nuclear, espectrofotometria na região do visível, difração de raios X e análise termogravimétrica (TGA). O teste de susceptibilidade in vitro da cepa de Streptococcus mutans frente ao QAMP foi realizado antes e após a incorporação no sistema adesivo Clearfil SE Bond. Clearfil Protect Bond, o qual contém um antimicrobiano padrão [MDPB] e Clearfil SE Bond sem QAMP foram usados como controles positivo e negativo, respectivamente. Realizou-se também a avaliação da porcentagem de liberação do composto quaternário de amônio a partir do sistema adesivo em estudo, após intervalos de tempo prédeterminados (1, 7, 14, 21 e 30 dias). Os dados espectroscópicos confirmaram que QAMP foi obtido com sucesso. A análise térmica indicou que QAMP foi estável ao calor. O efeito antimicrobiano contra Streptococcus mutans, antes e após a incorporação ao sistema adesivo odontológico, foi comprovado. A liberação de compostos quaternários de amônio do sistema adesivo em estudo foi muito reduzida, quando comparada ao do produto comercial [MDPB]. Além ! *+! disso, investigou-se o efeito de Clearfil® SE Bond contendo QAMP sobre a permeabilidade vascular usando os métodos de azul de Evans e fluxometria por laser-Doppler a fim de avaliar a influência sobre a fase exsudativa do processo inflamatório no tecido subcutâneo de ratos. Resultados confirmam que o sistema adesivo contendo QAMP teve um menor efeito sobre esta fase, o que é indicativo de uma adequada biocompatibilidade. Na tentativa de cercar a estabilidade do QAMP foram avaliadas a resistência de união dos sistemas adesivos em estudo em dentes humanos extraídos, por meio do ensaio de microtração imediatamente, após 6 e 12 meses de armazenamento dos espécimes em forma de palitos. O grau de conversão in situ por análise micro- Raman da interface adesiva estabelecida por esses sistemas e in vitro por espectroscopia de infravermelho com Transformada de Fourier também foram avaliados. Dados obtidos confirmaram que o sistema adesivo autocondicionante com QAMP produz uma resistência de união eficaz sob condições in vitro e estabilidade do grau de conversão in situ e in vitro. Na avaliação das propriedades mecânicas, dureza e módulo de elasticidade, foram preparados dentes restaurados com os adesivos em estudo, sendo submetidos à indução de lesões artificiais de cárie por meio de ciclagem de pH e de cárie microbiológica. Posteriormente, os dentes foram cortados e as fatias submetidas ao teste de nanoindentação na região da interface de união resinadentina, conduzindo a verificação da qualidade do substrato formado. Em geral, Clearfil® SE Bond contendo QAMP proporcionou melhores propriedades mecânicas da interface resina-dentina do que outros adesivos autocondicionantes comerciais após desafios cariogênicos. Esses dados contemplam o desenvolvimento de polímeros quaternários de amônio para fornecer benefícios adicionais para os sistemas adesivos dentais amplamente utilizados em Odontologia.
4

The ion release behaviours and water sorption of novel resin-based calcium phosphate cement

AlZain, Afnan Omar, 1981- January 2010 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Calcium phosphate-filled restorative materials were developed to provide calcium (Ca) and phosphate (PO4) ions, which have been proposed to enhance remineralization of demineralized tooth structure. Recently, tricalcium phosphate (TCP)-filled restorative materials were introduced as an alternative to amorphous calcium phosphate. The TCP filler has a more crystalline structure than ACP and is therefore potentially stronger. The aim of the present study was to examine TCP-filled restorative resins at different concentration levels at different time intervals to characterize the concentrations of Ca and PO4 ions released, and to measure the water sorption (WS) of these resins. An in vitro study was conducted by formulating resin composite using TCP as the filler mixed with EBPADMA, HmDMA, and HEMA as the resin matrix. One-hundred- sixty samples were prepared, 40 samples of each filler concentration (30 percent, 40 percent, 50 percent, and 60 percent) by weight. From each filler concentration, 5 samples of each of the 8 time points (time intervals of 4 h, 8 h, 12 h, 24 h, 3 d, 7 d, 14 d, and 21 d) were immersed in 100-ml deionized water. Calcium and PO4 ions were measured using atomic absorption spectroscopy and light spectroscopy, respectively. Water sorption (WS) was measured according to ISO 4049 specification and then the WS and the diffusion coefficient were calculated. The significance level was set at p = 0.001. The results indicated that Ca and PO4 ion release increased with increasing filler level at a rate faster than being linear. In addition, WS results were very high and failed to meet the ISO 4049 specification requirement. Diffusion coefficient results were also high. One-way ANOVA test for only 21-day data revealed that there is a statistically significant difference in filler level percent, and two-way ANOVA testing revealed that there is a statistically significant interaction between time and filler level percent on the Ca, PO4 released and WS. It can be concluded that the concentrations of Ca and PO4 released and WS were affected by composition of the monomers, filler level and type, dispersion, and the absence of coupling agent. Although this TCP-filled restorative material may release Ca and PO4, it cannot serve as a restorative material due to high WS values. Further study is needed to improve the material and evaluate its ability in promoting remineralization of the tooth structure in order for it to serve its purpose.