• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • 5
  • Tagged with
  • 40
  • 20
  • 11
  • 10
  • 7
  • 7
  • 7
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Medidores de distância por triangulação a laser. / Laser triangulation rangefinders.

Mario Antonio Stefani 20 September 1995 (has links)
Os Medidores de Distância por Triangulação a Laser são sistemas optoeletrônicos destinados à medição de pequenas distâncias ou deslocamentos, sem contato físico direto. Estes equipamentos possuem um grande campo de aplicações industriais. Este trabalho descreve as diversas configurações que este equipamento pode se apresentar, discutindo suas vantagens relativas. São estudadas também as suas partes e os componentes mais indicados. O projeto detalhado de um medidor usando sensor tipo CCD, e apresentado. Algumas aplicações industriais deste modelo são relatadas e diversos métodos e sugestões de uso são apresentadas, com base nas experiências realizadas pelo autor. / Laser Triangulation Rangefinders are non-contact, optoelectronic devices for measurement of small displacements or distances. These devices offer a broad range of industrial applications. This work explains common configurations, parts and main components, comparing their advantages. A detailed project on a CCD based Laser Rangefinder is presented. Some industrial applications for that project are related, discussing practical aspects based on authors experience. Some potential applications are also suggested.
32

Otimização da proteção radiológica nas práticas para a produção de radiofármacos no IEN

Santos, Osvaldir Paulo dos, Instituto de Engenharia Nuclear 06 1900 (has links)
Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2017-12-14T11:11:58Z No. of bitstreams: 1 OSVALDIR PAULO DOS SANTOS M.pdf: 6450373 bytes, checksum: 37ecd7d74479a2e2aae778f61157de75 (MD5) / Made available in DSpace on 2017-12-14T11:11:58Z (GMT). No. of bitstreams: 1 OSVALDIR PAULO DOS SANTOS M.pdf: 6450373 bytes, checksum: 37ecd7d74479a2e2aae778f61157de75 (MD5) Previous issue date: 2004-06 / Este trabalho tem por objetivo atualizar e instituir procedimentos de proteção radiológica e treinar pessoas, visando a minimizar as doses oriundas das práticas para produção de radiofármacos no IEN/DlRA. Para contribuir com este objetivo, foi desenvolvido um sistema móvel de medições (SMMG-N) para melhor avaliar as taxas de dose gama e nêutrons geradas nessas práticas. Os resultados das. medições realizadas com este projeto, foram comparados com resultados obtidos por formas aleatórias de medições. Verificou-se com este estudo, que as monitorações realizadas com esse sistema reduziram as incertezas das medições, permitiram a padronização na forma de realizar os monitoramentos, além de facilitar o transporte dos monitores de radiação para as áreas. Esse estudo confirmou a necessidade de alterações no sistema de blindagens da câmara-alvo e caverna do KIPROS, para atender aos princípios de limitação de dose e otimização da radioproteção. / This works has arisen from the need of updating radiological protection procedures, creating new ones and training qualified personnel to perform radiological protection duties in a nuclear facility. The main purpose of the research was to assess and minimize gamma and neutron dose rates emitted during the produc.tion and handliing ofradiopharmaceuticals at IENlDlRA. A mobile measurements system (SMMG-N) was developed for on-site measurements. This system has proven to be more handy than the equipament formerly used for for this task. It has also proven to reduce the measurements uncertainties and to allow for the standardization of assessment procedures. He dose rates calculated using the data provided by this system have been compared with results obtained otherwise and good agreement was observed between them. This study has confirmed the need to improve the radiation shielding of KIPROS target-chamber and target vault in order to meet the radiological principIes of dose rate limitation and optimization.
33

Determinação da função de transferência de enlaces metálicos a partir de medições de impedância de entrada

RODRIGUES, Roberto Menezes 02 April 2012 (has links)
Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-10-05T16:43:28Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DeterminacaoFuncaoTransferencia.pdf: 8874800 bytes, checksum: 2cd17e212f48c1cdeff100a1289239ad (MD5) / Rejected by Edisangela Bastos (edisangela@ufpa.br), reason: on 2017-10-10T17:05:27Z (GMT) / Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-10-16T15:38:23Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DeterminacaoFuncaoTransferencia.pdf: 8874800 bytes, checksum: 2cd17e212f48c1cdeff100a1289239ad (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-11-14T14:33:14Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DeterminacaoFuncaoTransferencia.pdf: 8874800 bytes, checksum: 2cd17e212f48c1cdeff100a1289239ad (MD5) / Made available in DSpace on 2017-11-14T14:33:14Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_DeterminacaoFuncaoTransferencia.pdf: 8874800 bytes, checksum: 2cd17e212f48c1cdeff100a1289239ad (MD5) Previous issue date: 2012-04-02 / A tecnologia digital subscriber line (DSL) tem por objetivo explorar todo o potencial dos enlaces metálicos telefônicos no provimento de acesso em banda larga. Por outro lado, os enlaces metálicos podem apresentar capacidades de transmissão bem distintas devido a diferenças em suas topologias. Portanto, é importante mensurar a real capacidade de cada enlace antes da implantação do serviço DSL. Esse processo chama-se qualificação de enlaces. O cálculo da capacidade de transmissão de um enlace perpassa pela determinação de sua função de transferência. As técnicas de qualificação existentes determinam a função de transferência a partir da comunicação entre equipamentos na central e na casa do assinante ou indiretamente, a partir do conhecimento da topologia do enlace sob teste. Ambos os processos não são adequados num cenário de pré-implantação do serviço DSL, pois envolvem custos adicionais com envio de técnico a localidade do assinante, dependência de registros atualizados por parte das operadoras (quase nunca disponíveis) ou o emprego de técnicas sofisticadas de identificação de topologia. Assim sendo, o objetivo do presente trabalho é propor um método de determinação da função de transferência de enlaces metálicos que não necessite de conhecimento prévio da topologia, que utilize somente informações coletadas na central telefônica e que não necessite de intervenção humana na localidade do assinante. Essencialmente, a forma geral do método do método proposto descreve analiticamente a função de transferência do enlace sob teste em função de suas impedâncias de entrada em curto-circuito e circuito aberto, vistas a partir da central, e da sua assimetria. Também foi desenvolvido um algoritmo o qual estima a impedância de entrada em curto-circuito a partir da detecção das envoltórias da impedância em circuito aberto. Ao utilizar esse estimador conjuntamente com a forma geral do método proposto, é possível determinar a função de transferência a partir de uma única medição de impedância feita na central e sem nenhuma intervenção humana na localidade do assinante. O método proposto foi avaliado em duas etapas distintas. Na primeira, avaliou-se o desempenho da forma geral do método. Os testes consistiram de comparação com um método de referência, usando dados simulados para três enlaces; aplicação do método proposto a uma bateria de dados simulados gerados a partir de um gerador arbitrário de topologias; e aplicação do método a medições de impedância realizadas em laboratório com oito enlaces reais. A segunda etapa diz respeito à aplicação conjunta da forma geral do método e do estimador de impedância em curto-circuito para dois dos enlaces medidos em laboratório. Os resultados obtidos para dados simulados demonstram que a forma geral do método proposto tem comprovada eficácia, fornecendo estimativas bem abaixo do limiar definido (< 3 dB por tom DSL). Para dados medidos, a forma geral do método determinou a função de transferência de sete dos enlaces com desvio por tom abaixo de 1,5 dB, mas falhou para o enlace com duas derivações, sendo uma junto à localidade do assinante. Com relação aos resultados para a aplicação conjunta da forma geral e do estimador, as estimativas de função de transferência foram equivalentes àquelas obtidas pela forma geral do método proposto, apesar de apresentarem desvios mais acentuados no início e no final da faixa de frequências. Esses desvios mais acentuados devem-se principalmente a versão atual do bloco de detecção de envoltórias do estimador de impedância em curto-circuito, que apresenta desempenho limitado, sobretudo para enlaces com mais de duas seções seriais. / The digital subscriber line (DSL) technology aims at exploiting the full potential of the telephone metallic lines on providing broadband access. On the other hand, the telephone lines may have distinct transmission capacities due to differences on their topologies. Therefore, it is important to measure the actual transmission capacity of each line before the DSL service deployment. This process is called line qualification. The determination of the transmission capacity of metallic lines requires previous determination of their transfer function. The existent qualification techniques determine the transfer function from the communication between equipments at the central office and the customer’s premises or indirectly, from knowledge about the topology of the line under test. Both processes are not in line with a pre-deployment scenario since they imply additional costs with the dispatching of technicians to the subscriber’s site, dependency of updated records about the telephone network (rarely available) or use of sophisticated line topology techniques. Therefore, the goal of this work is to propose a method for determining the transfer function of metallic lines with the following features: it does not need previous knowledge about the line topology, it uses information collected just at the central office (CO) and it does not require any human intervention at the subscriber’s site. Essentially, the general form of the proposed method analytically describes the transfer function of the line under test in function of its short and open-circuited input impedances, taken from the CO, and its asymmetry. Additionally, an algorithm that derives the short-circuited input impedance from the envelopes of the open-circuited one was developed. By applying this algorithm together with the general form of the proposed method, it is possible to determine the transfer function from just an open-circuited input impedance measurement and without any human intervention at the subscriber’s site. The proposed method was evaluated in two steps. The first step concerns the evaluation of the general form of the method. Specifically, the tests involve baseline comparison using simulated data for threeline topologies, application of the method to a bunch of simulated data generated from an arbitrary lines generator, and evaluation using measurements performed in laboratory for eight real test lines. The second step concerns the joint application of the general form of the method and the algorithm that estimates the short-circuited input impedance to measured data for two of the test lines reproduced in laboratory. The results for simulated data indicate that the general form of the proposed method is efficient, providing estimates well below the defined threshold (< 3 dB per DSL tone). For measurements, the general form of the method has estimated the transfer function of seven from the test lines with deviation per tone below 1.5 dB, but it failed for the line with two bridged-taps, being one very close to the subscriber’s site. Concerning the joint application of the general form of the proposed method and the algorithm that estimates the short-circuited input impedance, the transfer function estimations have been equivalent to those provided by the general form of the method, but with significant deviations in the beginning and in the end of the frequency band. These significant deviations are due to the current version of the envelope detector block of the algorithm that has limited performance, especially for lines with more than two serial sections.
34

Melhoria na consistência da contagem de pontos de função com base na Árvore de pontos de função / Improvement in the consistency of function point counting based on the Function Points Tree

Freitas Junior, Marcos de 08 December 2015 (has links)
Análise de Pontos de Função (APF) é uma das medidas usadas para obter o tamanho funcional de um software. Determinou-se, no Brasil, que toda contratação pública de desenvolvimento de software deve usar APF. Entretanto, uma das principais críticas realizadas a APF diz respeito à falta de confiabilidade entre diferentes contadores em uma mesma contagem já que, segundo alguns pesquisadores, as regras de APF são subjetivas, obrigando que cada contador faça interpretações individuais a partir delas. Existem diversas propostas para que se possa aumentar a confiabilidade dos resultados gerados com APF. Em geral, as abordagens propostas realizam mapeamentos entre componentes de artefatos desenvolvidos no ciclo de vida de software com os conceitos de APF. Porém, tais propostas simplificam em mais de 50% as regras previstas em APF comprometendo a validade dos resultados gerados pelas contagens. Como o tamanho do software é usado na derivação de outras medidas, inconsistências nos tamanhos medidos podem comprometer as medidas derivadas, o que influência negativamente nas decisões tomadas. Sem padronização dos tamanhos funcionais obtidos e consequentemente sem confiabilidade dos resultados obtidos, medidas derivadas a partir do tamanho funcional, como custo e esforço, podem estar comprometidas, fazendo com que ela não ajude a influenciar positivamente tais projetos. Diante desse contexto, o objetivo deste trabalho é desenvolver e avaliar experimentalmente uma abordagem para oferecer maior padronização e sistematização na aplicação de APF. Para isso, propõe-se incorporar o artefato Árvore de pontos de função ao processo de APF. Sua inclusão possibilitaria o levantamento de dados adicionais, necessários à contagem de pontos de função, reduzindo a ocorrência de interpretações pessoais do contador, e consequentemente, a variação de tamanho reportado. A abordagem foi denominada como Análise de Pontos de Função baseada em Árvore de Pontos de Função (APF-APF). Este trabalho baseia-se no método de pesquisa Design Science, cujo objetivo é estender os limites do ser humano e as capacidades organizacionais, criando novos artefatos que solucionem problemas ainda não resolvidos ou parcialmente resolvidos; que neste trabalho, trata-se da falta de confiabilidade na aplicação de APF devido à sua margem para diferentes interpretações. APF-APF foi testada com 11 Analistas de Sistemas / Requisitos que, baseados na especificação de um software de Recursos Humanos medido oficialmente pelo IFPUG com 125 pontos de função, modelaram a Árvore de pontos de função de modo manual ou automatizado via protótipo de ferramenta desenvolvido. Os resultados obtidos indicam que os tamanhos funcionais calculados com APF-APF possuem coeficiente de variação, respectivamente de 10,72% em relação a confiabilidade e 17,61% em relação a validade dos resultados de medição gerados. Considera-se que a abordagem APF-APF mostrou potencial para que melhores resultados possam ser obtidos. Verifica-se que a principal causa das variações observadas estava relacionada a ausência de informações requeridas para a Árvore de pontos de função, não tendo sido identificado nenhum problema específico em relação as regras definidas para APF-APF. Por fim, verificou-se que o uso do protótipo de ferramenta desenvolvido aumenta em até 47% a eficiência na contagem de pontos de função quando comparado com APF-APF manual / Function point analysis (FPA) is one of the measures used to achieve the functional size of software. It was determined, in Brazil, public procurement of software development should use FPA. However, one of the main criticisms made the FPA concerns the lack of reliability between different counters on the same count that, according to some researchers, the FPA rules are subjective, requiring that each counter do individual interpretations from them. There are various proposals in order to increase the reliability of the results generated with FPA. In General, the proposed approaches perform mappings between artifacts developed components in software life cycle with the concepts of FPA. However, such proposals simplify in more than 50% the rules laid down in FPA compromising the validity of the results generated by the scores. As the size of the software is used in the derivation of other measures, inconsistencies in sizes measured may compromise the measures derived, which negatively influence the decisions taken. Without standardization of functional sizes obtained and consequently without reliability of the results obtained, derived from measures of functional size, cost and effort, may be compromised, causing it to not help to positively influence these projects. In this context, the objective of this work is to develop and experimentally evaluate one approach to offer greater standardization and systematization in the implementation of FPA. For this, it is proposed to incorporate the artifact \"function point Tree\" to the FPA process. Its inclusion would allow additional data collection necessary for function point count, reducing the occurrence of personal interpretations of the counter, and consequently, the variation of size reported. The approach was called as Function Point Tree-based Function Point Analysis (FPT-FPA). This work is based on the method of Design Science research, whose goal is to extend the limits of the human and organizational capacities, creating new artifacts to troubleshoot unresolved or still partially resolved; in this work, it is the lack of reliability in application of FPA because of its scope for different interpretations. FPT-FPA were tested with 11 Systems analysts / requirements analysts, based on the specification of a human resources software measured by the IFPUG with 125 points, have modeled the function point Tree manually or via automated tool prototype developed. The results obtained indicate that the functional sizes calculated with FPT-FPA have coefficient of variation, respectively of 10.72% for reliability and 17.61% in relation to the validity of the measurement results generated. The FPA approach showed potential for better results can be obtained. It turns out that the main cause of the variations observed were related to the absence of information required for the tree of function points have not been identified any particular problem regarding the rules defined for FPT-FPA. Finally, it was found that the use of a prototype tool increases by up to 47% on efficiency function point count when compared to FPT-FPA manual
35

Melhoria na consistência da contagem de pontos de função com base na Árvore de pontos de função / Improvement in the consistency of function point counting based on the Function Points Tree

Marcos de Freitas Junior 08 December 2015 (has links)
Análise de Pontos de Função (APF) é uma das medidas usadas para obter o tamanho funcional de um software. Determinou-se, no Brasil, que toda contratação pública de desenvolvimento de software deve usar APF. Entretanto, uma das principais críticas realizadas a APF diz respeito à falta de confiabilidade entre diferentes contadores em uma mesma contagem já que, segundo alguns pesquisadores, as regras de APF são subjetivas, obrigando que cada contador faça interpretações individuais a partir delas. Existem diversas propostas para que se possa aumentar a confiabilidade dos resultados gerados com APF. Em geral, as abordagens propostas realizam mapeamentos entre componentes de artefatos desenvolvidos no ciclo de vida de software com os conceitos de APF. Porém, tais propostas simplificam em mais de 50% as regras previstas em APF comprometendo a validade dos resultados gerados pelas contagens. Como o tamanho do software é usado na derivação de outras medidas, inconsistências nos tamanhos medidos podem comprometer as medidas derivadas, o que influência negativamente nas decisões tomadas. Sem padronização dos tamanhos funcionais obtidos e consequentemente sem confiabilidade dos resultados obtidos, medidas derivadas a partir do tamanho funcional, como custo e esforço, podem estar comprometidas, fazendo com que ela não ajude a influenciar positivamente tais projetos. Diante desse contexto, o objetivo deste trabalho é desenvolver e avaliar experimentalmente uma abordagem para oferecer maior padronização e sistematização na aplicação de APF. Para isso, propõe-se incorporar o artefato Árvore de pontos de função ao processo de APF. Sua inclusão possibilitaria o levantamento de dados adicionais, necessários à contagem de pontos de função, reduzindo a ocorrência de interpretações pessoais do contador, e consequentemente, a variação de tamanho reportado. A abordagem foi denominada como Análise de Pontos de Função baseada em Árvore de Pontos de Função (APF-APF). Este trabalho baseia-se no método de pesquisa Design Science, cujo objetivo é estender os limites do ser humano e as capacidades organizacionais, criando novos artefatos que solucionem problemas ainda não resolvidos ou parcialmente resolvidos; que neste trabalho, trata-se da falta de confiabilidade na aplicação de APF devido à sua margem para diferentes interpretações. APF-APF foi testada com 11 Analistas de Sistemas / Requisitos que, baseados na especificação de um software de Recursos Humanos medido oficialmente pelo IFPUG com 125 pontos de função, modelaram a Árvore de pontos de função de modo manual ou automatizado via protótipo de ferramenta desenvolvido. Os resultados obtidos indicam que os tamanhos funcionais calculados com APF-APF possuem coeficiente de variação, respectivamente de 10,72% em relação a confiabilidade e 17,61% em relação a validade dos resultados de medição gerados. Considera-se que a abordagem APF-APF mostrou potencial para que melhores resultados possam ser obtidos. Verifica-se que a principal causa das variações observadas estava relacionada a ausência de informações requeridas para a Árvore de pontos de função, não tendo sido identificado nenhum problema específico em relação as regras definidas para APF-APF. Por fim, verificou-se que o uso do protótipo de ferramenta desenvolvido aumenta em até 47% a eficiência na contagem de pontos de função quando comparado com APF-APF manual / Function point analysis (FPA) is one of the measures used to achieve the functional size of software. It was determined, in Brazil, public procurement of software development should use FPA. However, one of the main criticisms made the FPA concerns the lack of reliability between different counters on the same count that, according to some researchers, the FPA rules are subjective, requiring that each counter do individual interpretations from them. There are various proposals in order to increase the reliability of the results generated with FPA. In General, the proposed approaches perform mappings between artifacts developed components in software life cycle with the concepts of FPA. However, such proposals simplify in more than 50% the rules laid down in FPA compromising the validity of the results generated by the scores. As the size of the software is used in the derivation of other measures, inconsistencies in sizes measured may compromise the measures derived, which negatively influence the decisions taken. Without standardization of functional sizes obtained and consequently without reliability of the results obtained, derived from measures of functional size, cost and effort, may be compromised, causing it to not help to positively influence these projects. In this context, the objective of this work is to develop and experimentally evaluate one approach to offer greater standardization and systematization in the implementation of FPA. For this, it is proposed to incorporate the artifact \"function point Tree\" to the FPA process. Its inclusion would allow additional data collection necessary for function point count, reducing the occurrence of personal interpretations of the counter, and consequently, the variation of size reported. The approach was called as Function Point Tree-based Function Point Analysis (FPT-FPA). This work is based on the method of Design Science research, whose goal is to extend the limits of the human and organizational capacities, creating new artifacts to troubleshoot unresolved or still partially resolved; in this work, it is the lack of reliability in application of FPA because of its scope for different interpretations. FPT-FPA were tested with 11 Systems analysts / requirements analysts, based on the specification of a human resources software measured by the IFPUG with 125 points, have modeled the function point Tree manually or via automated tool prototype developed. The results obtained indicate that the functional sizes calculated with FPT-FPA have coefficient of variation, respectively of 10.72% for reliability and 17.61% in relation to the validity of the measurement results generated. The FPA approach showed potential for better results can be obtained. It turns out that the main cause of the variations observed were related to the absence of information required for the tree of function points have not been identified any particular problem regarding the rules defined for FPT-FPA. Finally, it was found that the use of a prototype tool increases by up to 47% on efficiency function point count when compared to FPT-FPA manual
36

Estudo Experimental de Gases em Camadas de Cobertura no Aterro de Nova Iguaçu - RJ. / Experimental study of gases in cover layers of the landfill Nova Iguaçu - RJ.

Eduardo Gaiotto Marques da Silva 05 March 2011 (has links)
Esta pesquisa apresenta uma revisão bibliográfica sobre as emissões de metano em aterros sanitários, os conceitos de geração de gases em aterros sanitários, movimentações de gases em aterro, apresenta os métodos de medição de gases in situ, tipos de cobertura finais para aterros e a oxidação do metano na camada de cobertura. A pesquisa também tem como objetivo medir as emissões de gases e avaliar a infiltração das águas pluviais através da camada de cobertura do aterro sanitário da CTR Nova Iguaçu. As medições foram realizadas nos meses de julho a novembro de 2010, na camada de cobertura monolítica existente e em outra construída sobre uma barreira capilar. Sensores para medir temperatura e umidade foram instalados em profundidade nas duas camadas. Foram realizados ensaios de placa de fluxo para medir a composição dos gases e o fluxo através dos dois tipos de camadas, e avaliadas duas situações: com os poços de extração de gás ativos e desligados. Os sensores indicaram que em período de baixa pluviosidade, a barreira capilar apresenta uma eficácia superior à camada monolítica, e com a intensificação das chuvas, as umidades medidas nos dois tipos de camadas aumentam, e na barreira capilar o gradiente estabelecido entre os sensores diminui, indicando uma possível tendência à saturação desta barreira capilar. Porém, com a paralisação das chuvas, recupera e retoma sua condição inicial. Os resultados de medidas dos gases demostraram a eficiência do sistema de extração de gás quando ativado, resultando em emissões quase nulas de metano e gás carbônico nos dois tipos de camadas. No entanto, quando o sistema está desativado, as emissões através da camada monolítica são cerca de 3 vezes maiores do que através da barreira capilar. / This research presents a literature review on methane emissions from landfills, the concepts of landfill gas generation, the landfill internal gas flow, introduces the methods of measurement of gases "in situ", types of final landfill coverage and the methane oxidation in the cover layer. The research also purposes to measure greenhouse gas emissions and to evaluate the infiltration of rainwater through the landfill cover layer of the CTR Nova Iguaçu. Measurements were made in the months from July to November 2010, the existing monolithic cover layer and another built on a capillary barrier. Sensors to measure temperature and humidity were installed in two layers in depth. Plate assays were performed to measure the flow of the gas composition and flow through the two types of layers, and evaluated two situations with the gas extraction wells active and off. The sensors have indicated that in times of low rainfall, the capillary barrier has superior efficacy to the monolithic layer, and with the intensification of rain, the moisture content measured on two types of layers increase, the capillary barrier and the gradient established between sensors decreases, indicating a possible trend to saturation of capillary barrier. However, with the stoppage of rain, recovers and returns to its initial condition. The results of measurements of gases demonstrated the efficiency of extraction of gas when activated, resulting in near zero emissions of methane and carbon dioxide in the two types of layers. However, when the system is off, the emissions through the monolithic layer is about three times larger than through the capillary barrier.
37

Avaliação de ferramenta de simulação da transmissão sonora para projetos de isolamento acústico em edificações habitacionais

Silva, Renata Costa da 19 July 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In July, 2013, Brazil s new standard, NBR15575:2013, began to require minimum thermal, luminal, structural and acoustical performance levels in new constructions of residential dwellings. Thus, computer programs that simulate the sound transmission in buildings, can serve as important tools for professionals, enabling the verification of virtual acoustic performance of projects, quickly and economically. By being widely used in European countries, they have the database of existing elements and building systems in Europe. From this, this study aimed to evaluate a computational tool of simulation of sound transmission on the reality of Brazilian buildings. Twenty households were selected in the city of Santa Maria - RS, to be measured in situ and then simulated to airborne and impact noise. The residences were chosen according to standard and types of building systems. For greater representation of Brazilian buildings, residences of low, medium and high standards were chosen. The building systems chosen were structural masonry, structural walls with concrete or ceramic block; and reinforced concrete, with walls of hollow brick; all with massive concrete slab. The software used for the simulations was the SONarchitect and all the features and building elements used were entered into the software s database. The values of Lœn,T , Dn,T , and RT per frequency band, and their weighted values Lœn,T,w, Dn,T,w and mean RT were obtained through measurements and simulation. The weighted measured and simulated values were similar, on the other hand, the values obtained by frequency band showed disagreement with the lower frequencies precisely, from 50 Hz to 100 Hz. There was also a relationship of impact sound transmission loss with the area size of the partition, in which there is a significant increase in sound insulation in partitions with larger areas. In addition, coefficients and safety factors were determined for each standard and building system to be applied in the spectra of the simulations, aiming to bring the simulated values closer to the measured ones. Parallel with the evaluation of the computational tool, questionnaires with 150 professionals who develop acoustic projects in the country were applied. This step had as main objective to find out what tools and methods are mostly used by professionals in the development of these projects. From 31 received responses, it was determined that 20.88% of the professionals use a computational tool to develop designs. It was also possible to discover some features such as field of expertise and graduation year, which regions they are located, what kind of projects they develop and if they have already developed projects based on the new standard. / Com a entrada em vigor, em julho de 2013, da nova norma brasileira, NBR 15575:2013, passaram a ser exigidos nas novas construções de uso multifamiliar, níveis mínimos de desempenho, tais como térmico, ilumínico, estrutural e acústico. Dessa maneira, programas computacionais que simulam a transmissão sonora em edificações, podem servir como ferramentas importantes aos profissionais, permitindo a verificação do desempenho acústico virtual dos projetos, de forma rápida e econômica. Por serem amplamente utilizados nos países europeus, possuem banco de dados dos elementos e sistemas construtivos existentes na Europa. A partir disso, esse trabalho teve como objetivo a avaliação de uma ferramenta computacional, de simulação da transmissão sonora, para a realidade das construções brasileiras. Foram selecionadas 20 residências, na cidade de Santa Maria - RS, para serem medidas in loco e depois simuladas, aos ruídos aéreo e de impacto. As residências foram escolhidas, de acordo com padrão e sistemas construtivos. Para maior representatividade das construções brasileiras, foram escolhidas residências do padrão baixo, médio e alto. Os sistemas construtivos escolhidos foram alvenaria estrutural, com paredes de bloco estrutural de concreto ou cerâmico; e concreto armado, com paredes de tijolo vazado; todos com laje maciça de concreto. O programa utilizado para as simulações foi o SONarchitect e todas as características, dos elementos construtivos utilizados, foram inseridos no banco de dados do software. Foram obtidos os valores de Lœn,T , Dn,T,, e TR por banda de frequência, e seus valores ponderados de Lœn,T,w, Dn,T,w e TR médio, nas medições e simulações. Os valores ponderados medidos e simulados foram similares, por outro lado os valores obtidos por banda de frequência apresentaram divergência em relação às frequências mais baixas, precisamente de 50 Hz a 100 Hz. Verificou-se também uma relação da perda de transmissão sonora ao ruído de impacto com o tamanho da área da partição, na qual ocorre um aumento significativo no isolamento sonoro em partições com áreas maiores. Além disso, foram determinados coeficientes e fatores de segurança, para cada padrão e sistema construtivo, a serem aplicados nos espectros das simulações. Com o objetivo de aproximar os valores simulados dos valores medidos. Paralelamente à avaliação da ferramenta computacional, foram aplicados questionários com 150 profissionais que desenvolvem projetos acústicos no país. Essa etapa tinha como objetivo principal descobrir quais ferramentas e métodos são mais utilizados pelos profissionais no desenvolvimento desses projetos. A partir de 31 questionários respondidos, foi possível determinar que 20,88% dos profissionais utilizam alguma ferramenta computacional para desenvolver os projetos. Também foi possível descobrir algumas características desses profissionais como curso e ano de formação, quais as regiões que estão inseridos, que tipo de projetos desenvolvem e se já desenvolveram projetos baseados na nova norma.
38

Estudo Experimental de Gases em Camadas de Cobertura no Aterro de Nova Iguaçu - RJ. / Experimental study of gases in cover layers of the landfill Nova Iguaçu - RJ.

Eduardo Gaiotto Marques da Silva 05 March 2011 (has links)
Esta pesquisa apresenta uma revisão bibliográfica sobre as emissões de metano em aterros sanitários, os conceitos de geração de gases em aterros sanitários, movimentações de gases em aterro, apresenta os métodos de medição de gases in situ, tipos de cobertura finais para aterros e a oxidação do metano na camada de cobertura. A pesquisa também tem como objetivo medir as emissões de gases e avaliar a infiltração das águas pluviais através da camada de cobertura do aterro sanitário da CTR Nova Iguaçu. As medições foram realizadas nos meses de julho a novembro de 2010, na camada de cobertura monolítica existente e em outra construída sobre uma barreira capilar. Sensores para medir temperatura e umidade foram instalados em profundidade nas duas camadas. Foram realizados ensaios de placa de fluxo para medir a composição dos gases e o fluxo através dos dois tipos de camadas, e avaliadas duas situações: com os poços de extração de gás ativos e desligados. Os sensores indicaram que em período de baixa pluviosidade, a barreira capilar apresenta uma eficácia superior à camada monolítica, e com a intensificação das chuvas, as umidades medidas nos dois tipos de camadas aumentam, e na barreira capilar o gradiente estabelecido entre os sensores diminui, indicando uma possível tendência à saturação desta barreira capilar. Porém, com a paralisação das chuvas, recupera e retoma sua condição inicial. Os resultados de medidas dos gases demostraram a eficiência do sistema de extração de gás quando ativado, resultando em emissões quase nulas de metano e gás carbônico nos dois tipos de camadas. No entanto, quando o sistema está desativado, as emissões através da camada monolítica são cerca de 3 vezes maiores do que através da barreira capilar. / This research presents a literature review on methane emissions from landfills, the concepts of landfill gas generation, the landfill internal gas flow, introduces the methods of measurement of gases "in situ", types of final landfill coverage and the methane oxidation in the cover layer. The research also purposes to measure greenhouse gas emissions and to evaluate the infiltration of rainwater through the landfill cover layer of the CTR Nova Iguaçu. Measurements were made in the months from July to November 2010, the existing monolithic cover layer and another built on a capillary barrier. Sensors to measure temperature and humidity were installed in two layers in depth. Plate assays were performed to measure the flow of the gas composition and flow through the two types of layers, and evaluated two situations with the gas extraction wells active and off. The sensors have indicated that in times of low rainfall, the capillary barrier has superior efficacy to the monolithic layer, and with the intensification of rain, the moisture content measured on two types of layers increase, the capillary barrier and the gradient established between sensors decreases, indicating a possible trend to saturation of capillary barrier. However, with the stoppage of rain, recovers and returns to its initial condition. The results of measurements of gases demonstrated the efficiency of extraction of gas when activated, resulting in near zero emissions of methane and carbon dioxide in the two types of layers. However, when the system is off, the emissions through the monolithic layer is about three times larger than through the capillary barrier.
39

Avaliação da qualidade da energia elétrica em um campus universitário

Silva, Laura Chiovato 05 December 2014 (has links)
The development and expansion of the federal universities throughout the past years, due to the plans of expansion implemented with the funds from REUNI (The program of supporting for the restructuring and expansion of Federal Universities), suggest the necessity of improving the electrical installations of these institutions in order to meet the new power demand in a planned and efficient way. The subject which is related to the growing costs of electrical energy and investments in electrical installations in teaching institutions, faced with its economic relevance, represents, nowadays, an extremely relevant theme. Therefore, currently, it is possible to observe efforts directed to enhance the procedure of quality and efficiency diagnosis of the electrical energy of a campus. Embedded in this context is this dissertation, which is linked to a measurement plan, analysis methods and data comparison with reference values and the use of tools for modeling and computer simulation. This way, the present work presents four different kinds of contribution to the current state-of-the-art. The first contribution is associated to the obtention of typical charge curves and tax modal analysis chart which seem to be most adequate for a university campus. The second contribution is associated to the methodology of data analysis and the installation diagnosis in terms of power quality. As a third contribution of this work, we have the modeling of the electrical system of installation with the use of the ATP (Alternative Transients Program) computer tool. As a final contribution one can highlight the computer modeling and simulation to identify the harmonic contributions both to the local power utility and to the campus installations, together with the point of common coupling. The obtained results show that the methodology in use is very useful in the daily management of the processes associated with the use of the electrical energy in the installations of a university. / O crescimento e a modernização da carga das universidades federais ao longo dos últimos anos, em função de seus planos de expansão propostos e financiados com recursos do Programa de Apoio a Planos de Reestruturação e Expansão das Universidades Públicas (REUNI), sugerem a melhoria das instalações elétricas destas instituições para atender as novas demandas de energia elétrica de forma planejada e eficiente. O assunto relacionado aos crescentes custos com a energia elétrica e investimentos nas instalações elétricas em instituições de ensino, diante da sua relevância econômica, representa, na atualidade, tema de extrema importância. Por conseguinte, constata-se, no momento, esforços direcionados para melhor consubstanciar os procedimentos de um diagnóstico de eficiência e qualidade da energia elétrica de um campus universitário. Nesse contexto se insere a presente dissertação de mestrado, a qual se encontra associada a um plano de medição, a métodos para análise e comparação de dados com valores de referência e ao uso de ferramentas para modelagens e simulações computacionais. Nesse sentido, o presente trabalho apresenta quatro contribuições ao estado da arte atual. A primeira contribuição está associada com a obtenção de curvas de carga típicas e de tabelas de análise da modalidade tarifária mais adequada para um campus universitário. A segunda contribuição do trabalho, por sua vez, está vinculada com a metodologia de análise de dados e de diagnóstico da instalação quanto à qualidade da energia elétrica. Na sequência, como terceira contribuição do trabalho, tem-se a modelagem do sistema elétrico da instalação em estudo utilizando-se a ferramenta computacional ATP (Alternative Transients Program). Finalmente, propõe-se uma modelagem e simulação computacional para identificar as contribuições harmônicas tanto da concessionária de energia elétrica local quanto das instalações do campus, junto ao ponto de entrega de energia elétrica. Os resultados obtidos mostram que as metodologias utilizadas são de grande utilidade na gestão diária dos processos associados ao uso da energia elétrica nas instalações de uma universidade. / Mestre em Ciências
40

Alocação ótima de medidores para fins de detecção de falhas / Optimum distribution of measurement units aiming fault detection

Acácio, Luciana Carvalho 25 August 2017 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-12-07T12:33:00Z No. of bitstreams: 1 lucianacarvalhoacacio.pdf: 3829408 bytes, checksum: 88a83782335531c4be76d1544699c7bb (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-12-22T11:27:58Z (GMT) No. of bitstreams: 1 lucianacarvalhoacacio.pdf: 3829408 bytes, checksum: 88a83782335531c4be76d1544699c7bb (MD5) / Made available in DSpace on 2017-12-22T11:27:58Z (GMT). No. of bitstreams: 1 lucianacarvalhoacacio.pdf: 3829408 bytes, checksum: 88a83782335531c4be76d1544699c7bb (MD5) Previous issue date: 2017-08-25 / Este trabalho propõe um método baseado em algoritmos genéticos para alocação ótima de medidores na rede. A partir da alocação dos medidores, é verificado a assertividade alcançada na detecção de defeitos monofásicos, por área, com impedância na média tensão de sistemas de distribuição. Assim, é avaliado o desempenho da metologia de alocação ótima dos medidores. A saída do algoritmo, indica as posições que os medidores devem ser alocados, que formarão as respectivas áreas de observações para detecção. Para realizar a detecção de defeitos em sistemas de distribuição foi desenvolvido também um método utilizando redes neurais artificiais, que é utilizado como rotina interna do método de alocação de medidores, onde as entradas são grandezas elétricas de tensão e corrente, podendo ser medições fasoriais e/ou não-fasoriais, oriundas dos medidores definidos no método de alocação. Esta variação de tipos de medições serviu para analisar o desempenho na detecção do defeito do emprego de diferentes tipos de equipamentos de medição. A escolha da detecção de defeitos monofásicos é baseada no fato de que estes são a grande maioria nos sistemas de distribuição. O método desenvolvido consegue detectar defeitos monofásicos com resistência de arco variando entre 0 a 200 ohms, considerando ainda, variação do carregamento do sistema. O método proposto para alocação, bem como a rotina para detecção de falhas foi desenvolvido no ambiente MatLab®. Os testes foram realizados em sistemas do IEEE, apresentando bons resultados. / The proposal of this work is to develop a method based on genetic algorithms for optimal allocation of measurements units the distribution grid, which aims to detect monophasic defects with impedance in the medium voltage of distribution systems. The detection is performed by artificial neural networks. The developed methodology for optimal distribution of meters indicates as output the positions that the units should be allocated, creating detection areas. Artificial neural networks were used to perform fault detection in distribution systems, which is an internal routine of the measurement units distribution method. The inputs of the artificial neural networks are voltage and current. These electrical parameters can be either phasor measurements and/or non-phasor, depending on the category of meters defined in the allocation algorithm. The performance of different types of measurement equipment was executed by the analysis of different measurement types. It was selected single-phase defects due to the fact that these are the vast majority of faults in distribution systems. The developed method is able to identify single-phase defects with arc resistance ranging from 0 to 200 ohms, and it is also capable of correctly detect faults when considering load variation. The method of measurement unit allocation and the fault detection algorithm were developed in the software MatLab®. Tests were performed in IEEE systems, presenting good results.

Page generated in 0.0508 seconds