• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 141
  • 14
  • 7
  • 7
  • 7
  • 6
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 163
  • 51
  • 42
  • 40
  • 39
  • 39
  • 26
  • 25
  • 23
  • 20
  • 19
  • 19
  • 17
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Bioxidação fungica de valenceno a nootkatona, bioflavorizante de grapefruit / Bioxidatio valencene a nootkatone, a grapefruit natural flavor substance

Zampieri, Luiz Arthur, 1970- 28 July 2006 (has links)
Orientador: Jose Augusto Rosario Rodrigues / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-07T19:55:40Z (GMT). No. of bitstreams: 1 Zampieri_LuizArthur_M.pdf: 1219190 bytes, checksum: 50f1c90b246b806bd16bb30df4ecbbaf (MD5) Previous issue date: 2006 / Resumo: Neste trabalho estudou-se a bioxidação do sesquiterpeno valenceno (C15H24), produzindo o bioflavorizante nootkatona (C15H22O), buscando as condições ótimas para obtenção do máximo rendimento. Esta reação foi realizada utilizando dois sistemas enzimáticos distintos: o sistema lacase/mediador (LMS) de Trametes versicolor com mediador HBT (hidroxibenzotriazol) ou TEMPO (tetrametilpiperidin-N-oxil) e o sistema utilizando o complexo enzimático do citocromo P-450 de Chaetomium globosum. Outros microorganismos testados foram Botrytis cinerea, Mortierella isabellina e Mortierella ramaniana. As diversas variáveis (pH, tempo de reação, concentrações de enzima, mediadores e indutores, condições de aeração, entre outras) envolvidas nas respectivas reações foram estudadas através de planejamento fatorial e modelagem de superfície de resposta. A utilização do sistema LMS de Trametes versicolor mostrou ser uma ferramenta viável para obtenção de nootkatona a partir de valenceno, embora tenhamos obtido rendimento inferior (17%, agitador orbital em pequena escala e 15 % em escala preparativa, sob aeração externa) descrito na literatura (25%, sob aeração, escala preparativa), o que torna nosso procedimento pouco viável para utilização em maior escala, apesar disso, os resultados foram condizentes com os obtidos em reações semelhantes descritos na literatura científica, onde o rendimento de sistemas LMS dificilmente ultrapassa os 15%. O sistema enzimático CYP-450 apresentou rendimento inferior ao sistema lacase/mediador e, este último sistema, HBT mostrou ser um mediador mais eficiente que TEMPO. / Abstract: In this work, we study the sesquiterpene valencene bioxidation (C15H24), which produces the nootkatona biological flavor substance (C15H22O), in an attempt to achieve the best conditions for optimum yield. This reaction was carried out using two different enzymatic systems: the Trametes versicolor laccase-mediator system with HBT mediators (hydroxybenzotriazol), or TEMPO (tetramethyl-piperidine-N-oxide), and the system using the Chaetomium globosum cythocrome P-450 enzymatic complex. Other microorganisms were tested, such as Botrytis cinerea, Mortierella isabellina and Mortierella ramaniana. The different variables involved in the respective reactions were studied by means of factorial planning and modeling the response system. The use of the Trametes versicolor LMS system proved to be a viable tool to obtain nootkatone from valencene, although we have obtained an inferior yield (17% with orbital agitator in small scale and 15% in preparatory scale, under external aeration) in comparison with the highest value described in literature (25% under aeration). Thus, our procedure presents little viability for large scale use, although results were in agreement with those obtained in similar reactions described in scientific literature, in which the yield produced by LMS systems rarely exceeds 15%. The CYP-450 enzymatic system presented lower yield in comparison with the laccase-mediator system and in the latter, HBT turned out to be more efficient than TEMPO. / Mestrado / Quimica Organica / Mestre em Química
102

Medidor de vazão por transferencia termica

Strieder, Andre 16 December 2004 (has links)
Orientador: Kamal Abdel Radi Ismail / Dissertação (mestrado profissional) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-04T02:08:56Z (GMT). No. of bitstreams: 1 Strieder_Andre_M.pdf: 5509615 bytes, checksum: 50eeec27792444c72caf472ea5132345 (MD5) Previous issue date: 2004 / Resumo: Neste trabalho procurou desenvolver-se um medidor de vazão que permitisse medir a vazão de ar em um duto fechado através do principio de transferência térmica. Para isto é necessário desenvolver um sensor termo-resistivo e estudar seu comportamento quando submetido a diferentes vazões e temperaturas. É necessário também projetar um circuito eletrônico microcontrolado para medir o sinal de tensão gerado pelo circuito do sensor, a temperatura do fluido e realizar cálculos para determinar a vazão. Utilizou-se método onde o sensor termo-resistivo opera em temperatura constante através de circuito de medição com amplificador operacional realimentado pela saída. A equação que rege o comportamento do sensor termo-resistivo em equilíbrio termodinâmico estático, quando é atravessado por uma corrente elétrica e está em um meio onde sofre a ação da velocidade de um fluido é utilizada para o cálculo da vazão.O cálculo é realizado pelo microcontrolador através de coeficientes, obtidos experimentalmente, que relacionam a velocidade do fluido com o coeficiente de transferência térmica do sensor.Os resultados obtidos com dois tipos de sensor diferentes foram analisados e comparados e o resultado final do cálculo de vazão foi comparado com um medidor de referência obtendo uma boa concordância. Os resultados deste trabalho demonstram a capacidade do sistema para medição de vazão de gases que pode ser estendida também para outros fluidos / Abstract: We described the development of a flow meter instrument that provides to measure the air flow in a closed tube employing the Thermal Transfer Principle. To achieve this purpose we developed a thermoresistive sensor and we studied your behaviour in different flows and temperatures. It was necessary to project an electronic microcontroled circuit to measure the voltage signal generated by the sensor circuit, the fluid temperature and to determine the flow through calculations. We employed the method that uses a constant temperature in the thermoresistive sensor by the measure with an operational amplifier which is a feedback control circuit. The equation that determines the thermoresistive behaviour in static thermodynamic equilibrium submitted to electric current and to fluid velocity is employed in the flow calculation. The calculation is realized by the microcontroler through experimental coefficients that determine the relation between the fluid velocity with the thermal transfer coefficient of the sensor. The results obtained with two different sensors were analyzed and compared. The final calculated experimental result was compared with the results of a standard meter, showing a good correlation. We demonstrated the capability of the flow measure of gases, but the system could be extrapoled for another fluids as liquids / Mestrado / Instrumentação e Controle Industrial / Mestre Profissional em Engenharia Mecanica
103

Determinação do teor de umidade em madeiras por meio de medidores elétricos / not available

Waldemir Rodrigues 02 July 1999 (has links)
A madeira quando seca é um excelente isolante elétrico, porém quando a umidade da madeira aumenta, essa característica diminui fazendo com que esta passe a conduzir a corrente elétrica. A determinação do teor de umidade permite um controle do custo de produção e qualidade da madeira, além de facilitar a utilização de tratamentos preservativos e pintura. O método de determinação do teor de umidade com o uso de estufa é o método mais exato, e por esta razão é utilizado como padrão para calibrar outras técnicas. Por outro lado, a verificação do teor de umidade por meio da estufa é muito demorado e danifica parte do componente a ser analisado. O objetivo deste trabalho é propor uma metodologia para calibrar medidores elétricos de umidade, utilizando espécies de dicotiledôneas nativas e coníferas de florestamento. Na experimentação realizada foi possível constatar que apesar da menor precisão na determinação de teores de umidade, o método que utiliza medidores de umidade do tipo resistência, permite com algumas correções, a obtenção de valores confiáveis para o controle de umidade de peças de madeira serrada. Para isso foram desenvolvidas expressões obtidas por meio de análise de regressão linear que possibilitam fazer as correções necessárias nas leituras realizadas com o medidor elétrico do tipo resistência. / Wood when dry is an excellent electric insulating material. However when the moisture content of wood increases, that feature decreases, which makes it conduct electric current. Determining the moisture content allows the control of the production cost and the quality of the timber, and also facilitates the use of preservative treatments and painting. The method for the determination of the moisture content using the kiln is the most exact method, and therefore it is used as standard to calibrate other techniques. On the other hand, the verification of the moisture content by means of the kiln takes toe much time and damages part of the component to be analyzed. The aim of this work is to propose a methodology to gauge electric moisture meters using species of tropical and forestation hardwood and softwood. The experiments made it possible to verify that, even having less accuracy in determining the moisture content, the method based on moisture electric meters allows, with some adjustments, a reliable data acquisition for the control of moisture content of sawed lumber. For this matter, equations were developed by means of linear regression analysis allowing the necessary corrections of the readings carried out with the electric measurer of the resistance type.
104

Implementación de un sistema informático de telemetría para el monitoreo de los parámetros de toma de lectura de medidores de altos consumidores de EPSEL S.A.

Sandoval Roque, Dominguin Antonino January 2023 (has links)
La Empresa Prestadora de Servicios de Saneamiento de Lambayeque – EPSEL S.A., actualmente cuenta aproximadamente con 175,000 conexiones de agua activas, de las cuales sobresalen un grupo de aproximadamente 950 conexiones de usuarios denominados “Altos Consumidores”, las mismas que representan el 20% de la recaudación total de la empresa. Durante el proceso de toma de lectura de medidores de altos consumidores muchas veces existe manipulación de los datos que se obtienen de cada medidor a conveniencia de los usuarios u operadores, lo que genera pérdidas económicas a la empresa. Lo que justifica la necesidad de un sistema que realice las tareas de manera automática, que evite cualquier manipulación por parte del personal y que cumpla los estándares de calidad requeridos. El objetivo de la investigación Implementar un sistema informático de telemetría para monitorear la toma de lectura de medidores de altos consumidores de la empresa EPSEL S.A. En la investigación se empleó la metodología SCRUM, para el diseño y desarrollo del sistema de telemetría. Y se tuvo como resultado el desarrollo del prototipo del medidor sincronizado con redes de celular que recepcionan y envían datos para la lectura del volumen de agua consumido, lo que validó su funcionalidad. Por último, se concluyó que este sistema de telemetría es funcional y se puede implementar en la empresa EPSEL S.A.
105

Diseño e implementación de una red de medidores de energía para artefactos domésticos

Huiman Tocto, Nelson Eduardo 27 March 2018 (has links)
La energía eléctrica es uno de los principales recursos de gran interés que garantiza el desarrollo; y pese a ello, las personas utilizan desmesuradamente sus artefactos eléctricos sin reconocer el gran valor de este recurso. Los consumidores pueden utilizar adecuadamente sus artefactos eléctricos mediante el uso de herramientas que le faciliten este fin y adoptando pautas para el desarrollo de una conducta que permita contribuir a la reducción gradual del consumo energético y a un ahorro significativo en la economía de sus hogares. Es así, como la presente tesis tiene como objetivo desarrollar una herramienta que le brinde al usuario información detallada del consumo de energía eléctrica de un conjunto de artefactos domésticos en su hogar. Esto se realizará mediante la implementación de una red de medidores de energía eléctrica y como resultado, el usuario será capaz de tomar una decisión consiente e informada en la adaptación de posibles medidas para el ahorro de energía eléctrica dentro de su hogar. Dado que los productos ofrecidos en el mercado son pocos y no versátiles para el usuario, se busca desarrollar un sistema que cubra todos los requerimientos; y por consiguiente, el usuario pueda tener acceso a la información de una manera rápida y sencilla. Finalmente, desarrollado el sistema de medición de energía eléctrica se realizarán las pruebas tomando en consideración los artefactos eléctricos comunes en el hogar. Estas primeras pruebas buscan determinar la correcta obtención de datos de los medidores. Posteriormente se realizarán las pruebas de envío de información mediante el uso de una red inalámbrica que permitirá el correcto manejo de la información obtenida en el paso previo. Como resultado final, el usuario logrará visualizar el consumo de energía de todos sus artefactos eléctricos en cada periodo de tiempo.
106

Modelagem, simulação e otimização de um difusor de biomassa / Modeling, simulation and optimization of biomass diffusers

Barbosa, Larissa de Souza Noel Simas 05 April 2019 (has links)
Difusores podem ser empregados para extração de sacarose da cana de açúcar e da beterraba, para a extração de tanino da casca de acácia negra e para extração de óleos vegetais de plantas oleaginosas. Apesar de operarem de forma simples do ponto de vista mecânico e químico, problemas que ocorrem na sua operação comprometem a eficiência de extração. A modelagem, simulação e otimização de difusores de biomassa mostra-se essencial para melhor compreender tais problemas e propor estratégias otimizadas de projeto e operação. Nesse contexto, a tese aqui proposta tem como objetivo principal modelar e simular a operação de um difusor de biomassa de 10 estágios (Biomassa entra pelo estágio 1 e sai do difusor pelo estágio 10. A água de embebição faz o trajeto em contracorrente, i.e. entra pelo estágio 10 e sai pelo estágio 1) para, posteriormente, otimizá-lo mono e multi-objetivamente considerando a possibilidade de conexão entre todos os estágios de extração. No caso da otimização mono-objetivo, no qual uma vazão de embebição de líquido fixa é considerada, o principal objetivo da otimização consiste em maximizar a concentração de soluto no líquido que deixa o difusor a partir de mudanças aleatórias nos coeficientes de conectividade do difusor. Já para a otimização multi-objetivo, a vazão de embebição de líquido que entra no difusor é considerada variável. Sendo assim, a otimização do sistema requer a maximização de dois objetivos simultaneamente (a maximização da concentração de soluto no líquido e minimização da concentração final de soluto na biomassa) a partir de mudanças aleatórias nos coeficientes de conectividade do difusor. Além disso, visto que a minimização de problemas operacionais está relacionada com a monitoração da altura de nível de líquido no leito de fibra, diferentes sinais para detecção de presença de líquido no leito de fibras em um estágio de extração experimental foram testados. Dos resultados de simulação e otimização obtidos, podemos concluir que novas conexões entre os estágios do difusor podem otimizar o processo de extração o que contraria o senso comum segundo o qual as conexões devem ser sequenciais. No caso da otimização mono-objetivo, 82 a 89% do fluido é direcionado para o estágio seguinte ao longo dos estágios de extração (exceto para o estágio 6, no qual esse valor é de 100%). A recirculação do fluido para o mesmo estágio é mais acentuada nos estágios finais (estágios 1 a 4), apresentando o difusor otimizado 14 a 18% de recirculação do fluido para o mesmo estágio nesses estágios enquanto para os demais estágios a recirculação varia entre 0 e 11%. Já para os estágios iniciais (estágios 5, 7, 8 e 9), a recirculação do fluido para o estágio anterior apresenta maior destaque, variando de 6 a 16% enquanto para os demais estágios é de apenas 0 a 2%. O estágio 6, por sua vez, é o único que se conecta exclusivamente com o estágio seguinte. Para a otimização multi-objetivo, resultados similares foram encontrados, sendo que a probabilidade de que 85 a 100% do fluido seja circulada para o estágio seguinte está entre 93 e 99%. Em relação a recirculação para o mesmo estágio, a probabilidade de que de 0 a 15% do fluido seja recirculado varia de 58 a 79% para os estágios 1 a 4, de 49 a 55% para os estágios medianos 5, 6 e 7 e de 60 a 90% para os três últimos estágios (estágios 8, 9 e 10). Para a conexão com o estágio imediatamente anterior, a probabilidade de que de 0 a 15% do fluido seja direcionado para o estágio anterior é maior nos estágios 1, 2, 8 e 9, variando entre 31 e 38%. Para a detecção da presença de líquido no leito de fibras em um estágio de extração, dois tipos de sinais diferentes, condutividade elétrica e radiação infravermelha, foram testados. Os testes foram realizados, em um estágio de extração experimental, primeiramente apenas com água e, em seguida, com bagaço de cana. Os medidores de condutividade mostraram-se estáveis e com repetitividade quando testados com água. Já nos testes realizados com bagaço de cana, o sinal de condutividade mostrou-se insuficiente para a detecção de líquido. Para os medidores de infravermelho testados com água, os mesmos apresentaram alguns sintomas de instabilidade e variabilidade. Quando testados com cana, os medidores de infravermelho também apresentam instabilidade e variâncias distintas que dependem da posição do medidor no difusor e, consequentemente, da compactação do leito de fibra. Infere-se então que um aumento da variância do sinal pode ser um indicativo de um aumento da compactação do leito e, consequentemente, de diminuição da sua permeabilidade. / Diffusers can be used to extract sucrose from sugarcane and sugarbeet, to extract tannin from black acacia bark and to extract oil from oleaginous plants. Although they operate simply from a mechanical and chemical point of view, problems that occur in their operation can compromise the extraction efficiency. The modeling, simulation and optimization of biomass diffusers is essential to better understand such problems and propose optimized strategies for their project and operation. In this context, the main objective of the proposed thesis is to model and simulate the operation of a ten- stage biomass diffuser to later optimize it mono and multi-objectively considering the possibility of connection among all extraction stages. In the case of the mono-objective optimization, in which a fixed liquid imbibition flow rate is considered, the main objective of the optimization is to maximize the concentration of solute in the liquid that leaves the diffuser from random changes in the connectivity coefficients of the diffuser. For the multi-objective optimization, the liquid imbibition flow rate entering the diffuser is considered variable. Therefore, the optimization of the system requires the maximization of two objectives simultaneously (the maximization of the solute concentration in the liquid and minimization of the final solute concentration in the biomass) from random changes in the diffuser connectivity coefficients. In addition, since the minimization of operational problems is related to the monitoring of liquid level height in the fiber bed, different types of signals for level measurement were tested on an experimental extraction stage. From the simulation and optimization results, we can conclude that new connections among the stages of the diffuser can optimize the extraction process which runs counter to common sense that connections must be sequential. In the case of the mono-objective optimization, 82 to 89% of the fluid is directed to the next stage along the extraction stages (except for stage 6, in which this value is 100%). The recirculation of the fluid to the same stage is more pronounced in the final stages (stages 1 to 4), with the optimized diffuser having 14 to 18% of fluid recirculation for the same stage in these stages while for the remaining stages the recirculation varies between 0 and 11%. For the initial stages (stages 5, 7, 8 and 9), fluid recirculation to the previous stage is more prominent, varying from 6 to 16% while for the remaining stages it is only 0 to 2%. Stage 6, in turn, is the only one that connects only to the next stage. For the multi-objective optimization, similar results were found, with the probability of 85 to 100% of the fluid being circulated to the next stage being between 93 and 99%. Regarding recirculation to the same stage, the probability of 0 to 15% of the fluid being recirculated varies from 58 to 79% for stages 1 to 4, from 49 to 55% for the medium stages 5, 6 and 7 and from 60 to 90% for the last three stages (stages 8, 9 and 10). For the connection to the immediately preceding stage, the probability that 0 to 15% of the fluid being directed to the previous stage is greater in stages 1, 2, 8 and 9, ranging from 31 to 38%. For liquid level measurement, two different types of signals, electrical conductivity and infrared radiation were tested. The tests were first carried out only with water and then with sugarcane bagasse. Conductivity meters were stable and repeatable when tested with water. In the tests performed with sugarcane bagasse, the conductivity signal was insufficient for level measurement. For water-tested infrared meters, they have shown some instability symptoms and variability. When tested with cane, the infrared meters exhibit instability and distinct variances that depend on the position of the meter in the diffuser and, consequently, bed compactation. It can be then inferred that an increase in the signal variance can be also an indicative of increased bed compactation and, consequently, decreased bed permeability.
107

Modelo vazão-velocidade para avaliação de potencial hidrocinético

CRUZ, Josias da Silva 25 May 2018 (has links)
Submitted by Ivone Costa (mivone@ufpa.br) on 2018-09-04T12:29:23Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ModeloVazaoVelocidade.pdf: 7237230 bytes, checksum: d46e07c193f9f0b9a8748df691536082 (MD5) / Approved for entry into archive by Ivone Costa (mivone@ufpa.br) on 2018-09-04T12:29:47Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ModeloVazaoVelocidade.pdf: 7237230 bytes, checksum: d46e07c193f9f0b9a8748df691536082 (MD5) / Made available in DSpace on 2018-09-04T12:29:47Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_ModeloVazaoVelocidade.pdf: 7237230 bytes, checksum: d46e07c193f9f0b9a8748df691536082 (MD5) Previous issue date: 2018-05-25 / A rede de informações hidrológicas brasileira disponibiliza dados de vazões diários, contudo, as informações de velocidades diárias não estão disponíveis em séries históricas. O inventário de velocidades dos rios é importante para muitas aplicações, e uma delas é o estudo de potencial hidrocinético, inclusive a jusante de centrais hidrelétricas. Portanto, o trabalho propõe um modelo denominado VazãoVelocidade que determina a velocidade média diária, a forma geométrica e a distribuição do perfil logarítmico de velocidade da seção transversal de rios a partir de dados de vazão diária. O modelo foi aplicado inicialmente em uma pequena bacia hidrográfica com dados de vazão e a validação foi realizada utilizando o erro médio quadrático – RMSE, o erro médio quadrático relativo - RRMSE, a razão do desvio padrão de observação – RSR e a porcentagem de viés – PBIAS. Posteriormente, o modelo foi aplicado às bacias hidrográficas dos rios Amazonas, São Francisco e Paraná (maiores bacias do Brasil), usando a maior e menor vazão da série histórica. A maior e menor velocidade média encontrada no rio Amazonas foi de 2,27 ms-1 e 0,735 ms-1 na seção transversal de Óbidos para uma vazão de 266 897 m³s-1 e 72 480 m³s-1, respectivamente. Os principais contribuintes do rio Amazonas, com exceções dos rios Trombetas, Madeira e Xingu, apresentam velocidades médias diárias abaixo de 2 ms-1 para o período de cheia, porém, no período de estiagem as velocidades médias diárias de todos são abaixo de 0,5 ms-1. O rio São Francisco, nas seções transversais estudadas ao longo de sua extensão, apresenta velocidades entre 3,087 ms-1 a 1,679 ms-1 para o período de cheia e no período de estiagem as velocidades estão entre 0,437 ms-1 a 0,116 ms-1. Já no rio Paraná, as velocidades estão entre 2,167 ms-1 a 1,504 ms-1 e 0,594 ms-1 a 0,118 ms-1 para a maior e menor vazão, na devida ordem. Verificou-se que o rio Amazonas tem potencial hidrocinético que pode ser explorado durante o ano todo. Na bacia do São Francisco, somente no período de maiores vazões há potencial para a instalação de turbinas hidrocinéticas, idem para a bacia do rio Paraná. É claro que, em pontos dos rios onde existam centrais hidrelétricas essa avaliação deve mudar devido ao despacho das centrais. / The Brazilian hydrological information network provides daily flow data; however, daily velocity information is not available in historical series. The inventory of river velocities is important for many applications, and one of them is the study of hydrokinetic potential, including downstream of hydroelectric plants. Therefore, the work proposes a model called Flow-Velocity that determines the average daily velocity, the geometric form and the distribution of the logarithmic velocity profile of the cross section of rivers from daily flow data. The model was initially applied in a small river basin with flow data and the validation was performed using the mean square error (RMSE), the relative mean square error (RRMSE), the standard deviation of observation (RSR) and the percentage of bias PBIAS. Subsequently, the model was applied to the river basins of the Amazonas, São Francisco and Paraná rivers (Brazil's largest basins), using the highest and lowest flows in the historical series. The highest and lowest average speed found in the Amazon River was 2.27 ms-1 and 0.735 ms-1 in the Óbidos cross-section for a flow of 266 897 m³s-1 and 72 480 m³-1, respectively. The main contributors to the Amazon River, with the exception of the Trombetas, Madeira and Xingu rivers, present average daily speeds below 2 ms-1 for the flood period, but in the dry season the average daily speeds of all are below 0.5 ms-1. The São Francisco river, in the transversal sections studied along its length, presents velocities between 3.09 ms-1 to 1.68 ms-1 for the period of flood and in the period of drought the speeds are between 0,44 ms-1 to 0,12 ms-1. In the Paraná River, velocities are between 2.17 ms-1 to 1.50 ms-1 and 0,59 ms-1 to 0,12 ms-1 for the greater and smaller flow, in due order. It was verified that the Amazon river has hydrokinetic potential that can be explored all year round. In the São Francisco basin, it is only in the period of higher flows that there is potential for the installation of hydrokinetic turbines, similar to the Paraná river basin. Of course, at points in rivers where there are hydroelectric plants, this assessment should change due to the dispatch of power plants.
108

Análise experimental e avaliação das incertezas em medição de líquidos com referência tipo ball prover

Lavezzo, Luís Fernando de Queiroz 09 April 2010 (has links)
Made available in DSpace on 2016-12-23T14:08:13Z (GMT). No. of bitstreams: 1 luiz fernando lavezzo.pdf: 2560237 bytes, checksum: 622accd559bcb34b4ded5fe0495d5d69 (MD5) Previous issue date: 2010-04-09 / This work is dedicated to the reference measurement of liquid flow aiming to deal with the peculiarities related to the subject, which reach great importance in commercial transactions involving typical interests of the oil industry. The flow measurement process however is not deterministic and involves a large number of variables that contributes to the doubt about of the real value that it proposes to measure. Such variables, which contribute to uncertainty in measurement, include a lot of aspects such constructive feature meter, fluid properties, environmental conditions and operator ability, for instance. This work presents a prototype project of a laboratorial scale ball prover, experimentally evaluate its performance, aiming to point out its alignment with the requirements established by the norms, considering the uncertainties in the measurement and the contribution of different lengths. Otherwise, it is procedured a comparison with a turbine meter calibrated by the manufacturer. / Este estudo se dedica à medição referencial de vazão de líquidos com o propósito de se lidar com as características específicas do funcionamento de um medidor, que tem suma importância nos interesses envolvendo transações comerciais na indústria de petróleo. O processo de medição de vazão envolve diversas variáveis que contribuem para a incerteza do real valor que se propõe medir. Estas variáveis vão desde características construtivas do medidor, propriedades do fluido a ser medido, das condições ambientais e perícia do operador. A proposta deste estudo é apresentar um projeto de protótipo laboratorial de medidor de referência tipo ball prover, avaliar experimentalmente seu desempenho e buscar se alinhar com os requisitos estabelecidos pelas normas. As incertezas inerentes à medição e sua contribuição em diferentes trechos será avaliada através de comparações com um medidor do tipo turbina, calibrado pelo fabricante.
109

Proposta de otimização de modelo de regionalização de curvas de permanência de vazões

SILVA, Raimunda da Silva e 16 May 2014 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T13:13:43Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_PropostaOtimizacaoModelo.pdf: 2967207 bytes, checksum: 09c11dcb40323d2971c8c5bf94450590 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-21T15:00:46Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_PropostaOtimizacaoModelo.pdf: 2967207 bytes, checksum: 09c11dcb40323d2971c8c5bf94450590 (MD5) / Made available in DSpace on 2017-03-21T15:00:46Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_PropostaOtimizacaoModelo.pdf: 2967207 bytes, checksum: 09c11dcb40323d2971c8c5bf94450590 (MD5) Previous issue date: 2014-05-16 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Devido à carência de dados de vazão no Estado do Pará, a regionalização de curvas de permanência de vazões, apresenta-se como uma técnica importante, permitindo a estimativa de vazões em locais com dados insuficientes ou inexistentes. Assim, o presente trabalho visa propor a otimização de um modelo de regionalização de curvas de permanência de vazões para a região paraense. O modelo teve como base de dados 43 estações fluviométricas distribuídas no Estado do Pará. As curvas de permanência foram calibradas utilizando-se 5 modelos matemáticos de regressão: potência, exponencial, logarítmico, quadrático e cúbico. O modelo de regionalização foi estabelecido, usando-se a técnica de regressão múltipla. A variação espacial dos parâmetros dos modelos foi explicada em termos de área de drenagem, precipitação média anual, comprimento e desnível do rio principal. O modelo foi validado através do procedimento de Jack-knife. O melhor ajuste do modelo cúbico foi representado matematicamente pelos erros quadráticos relativos médios percentuais (ϵ%), coeficientes de Nash-Sutcliffe (Nash) e pelos ajustes gráficos das vazões simuladas e observadas. A otimização do modelo, seguindo o método da tentativa e erro, deu-se pelo agrupamento das estações por área de drenagem e pela inserção de estações sintéticas. O número de estações sintéticas inseridas no modelo foi avaliado pelo Root Mean Square Error (RMSE), coeficiente de Nash e pelo ϵ%. Para os grupos I e II o número ótimo de estações sintéticas, que se juntaram às já consideradas nos grupos, foi 6 e 3, respectivamente. No grupo III somente o método de agrupamento em relação às áreas de drenagem foi suficiente para um bom desempenho do modelo de regionalização. O bom desempenho do modelo calibrado, validado e otimizado demonstrou o potencial deste na estimativa das curvas de permanência dos rios que cortam o Pará. As coordenadas geográficas das estações sintéticas, que otimizaram o modelo, podem servir como sugestão para o poder público de onde instalar novas estações. O número de novas estações seria limitado aos resultados da otimização, racionalizando-se recursos e aproveitando o modelo desenvolvido para determinar curvas de permanência de vazão para todo o estado do Pará. Nesse caso, as novas estações instaladas, também ajudariam, futuramente, a melhorar o desempenho do modelo. / Due to lack of data flow in the State of Pará, the regionalization of streamflow duration curves, presents itself as an important technique, allowing the estimation of flow in sites with insufficient or no data. Hus, this paper aims to propose the optimization of a model of regionalization of streamflow retention curves for the Para region. The model was based on data at 43 gauged stations distributed in the state of Pará. The flow duration curves were calibrated using 5 regression models: power, exponential, logarithmic, quadratic and cubic. Regionalization model was established using the multiple regression technique. The spatial variation of each parameter was explained in terms of the drainage area, mean annual precipitation, length and slope of the main river. The model was validated using the Jack -knife procedure. The best fit of the cubic model was mathematically represented by the quadratic mean relative errors (ϵ%), coefficients of Nash-Sutcliffe (Nash) and the graphics settings the simulated and observed streamflow. The optimization model was achieved by insertion of synthetic stations and cluster stations by drainage area. The number of synthetic stations included in the model were evaluated by Root Mean Square Error (RMSE), the coefficient of Nash and the ϵ%. For groups I and II the optimal number of synthetic stations, who joined those already considered in the groups, it was 6 and 3, respectively. In group III only the clustering method in relation to drainage areas was sufficient for good performance of the regionalization model. The good performance of the calibrated, validated and optimized model demonstrated the potential of this in the estimation of retention curves of the rivers that cross the Para. The geographic coordinates of synthetic stations, which optimized the model can serve as a suggestion to the government where to install new stations. The number of new stations would be limited to the results of optimization, streamlining resources and building up the model developed to determine retention curves flow for the entire state of Para. In this case, the new installed stations, would also help in the future to improve the model performance.
110

Desenvolvimento de um dinamômetro biomédico ergonômico com comunicação com dispositivos móveis /

Paulo, Danilo Pazian. January 2017 (has links)
Orientador: Aparecido Augusto de Carvalho / Resumo: Dinamômetros biomédicos são equipamentos utilizados para medir forças exercidas pelas mãos. Com o uso deste tipo de equipamento, é possível realizar avaliações biomecânicas das mãos de pacientes que após cirurgias, acidentes ou patologias osteomioarticulares, tiveram redução na sua capacidade de exercer forças com as mãos. O objetivo deste trabalho foi a implementação de um dinamômetro biomédico ergonômico, de fácil utilização, com capacidade de comunicação com diferentes tipos de dispositivos móveis, como smartphones e tablets. O projeto realizado se constitui no aprimoramento de duas versões anteriores de dinamômetros implementadas no Laboratório de Instrumentação Eletrônica e Engenharia Biomédica da UNESP –Campus de Ilha Solteira. Testes em voluntários utilizando o dinamômetro desenvolvido e um dinamômetro comercial da marca SAEHAN, e posterior análise estatística dos dados revelam uma excelente confiabilidade intra-examinador para o dinamômetro desenvolvido, com coeficiente de correlação intraclasse médio de 0,95 entre os diferentes grupos analisados, e de 0,98 para o dinamômetro SAEHAN. A análise estatística revela também uma excelente confiabilidade concorrente para as medidas realizadas pelo dinamômetro desenvolvido em relação às do dinamômetro SAEHAN, sendo de 0,93 para mãos dominantes e 0,92 para mãos não dominantes. Assim, o dinamômetro desenvolvido é confiável, válido e comparável com o dinamômetro SAEHAN quando adotados os mesmos procedimentos de exame de preensão... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Biomedical dynamometers are equipment used to measure forces exerted by the hands. Using this type of equipment, it is possible to perform biomechanical evaluations of the hands of patients that after surgery, accidents or diseases have had a reduction in the ability to exert force with their hands. The objective of this work was the implementation of an ergonomic biomedical dynamometer, easy to use, with ability to communicate with different types of mobile devices such as smartphones and tablets. The project carried out constitutes the improvement of two previous dynamometers versions implemented in the Electronic Instrumentation and Biomedical Engineering Laboratory at UNESP - Ilha Solteira. Volunteer tests using the developed dynamometer and a commercial SAEHAN dynamometer, and subsequent statistical analysis of the data revealed an excellent intra-examiner reliability for the developed dynamometer, a mean of 0,95 among different groups analyzed, and a mean of 0,98 for the SAEHAN dynamometer. The statistical analysis also revealed an excellent concurrent reliability for the measurements performed by the dynamometer developed in relation to those of the SAEHAN dynamometer, being 0,93 for dominant hands and 0,92 for non-dominant hands. Thus, the developed dynamometer is reliable, valid and comparable with the SAEHAN dynamometer when the same grip strength examination procedures were adopted. / Mestre

Page generated in 0.1489 seconds