• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 141
  • 14
  • 7
  • 7
  • 7
  • 6
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 163
  • 51
  • 42
  • 40
  • 39
  • 39
  • 26
  • 25
  • 23
  • 20
  • 19
  • 19
  • 17
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Desenvolvimento de um sistema de verifica??o da press?o arterial atrav?s do m?todo oscilom?trico

Pereira, L?o Fabr?cio 30 March 2006 (has links)
Made available in DSpace on 2015-04-14T13:56:37Z (GMT). No. of bitstreams: 1 346861.pdf: 1247028 bytes, checksum: 6cdf9feef272bc4395446fc3f7de312a (MD5) Previous issue date: 2006-03-30 / A verifica??o da medida de press?o arterial ? de grande import?ncia para o diagn?stico de doen?as cardiovasculares e principalmente para o acompanhamento de interven??es terap?uticas, por?m os m?todos invasivos hoje utilizados s?o caros e principalmente agressivos ao paciente, reduzindo por estes motivos sua aplica??o. Este estudo pretende obter, por m?todos n?o-invasivos, a medida da press?o arterial de pacientes humanos. Isto consiste na aquisi??o das press?es sist?licas, diast?licas e m?dias de forma "simultaneamente" bem como a apresenta??o destas num visor. Os valores adquiridos pelo m?todo n?o-invasivo ser?o comparados a dados resultantes da aquisi??o invasiva da press?o arterial por carater intra-a?rtico que ? considerado padr?o-ouro. Os sinais obtidos de maneira n?o-invasiva ser?o acondicionados diretamente no computador ap?s serem captados por uma placa de aquisi??o junto ao sensor que est? localizado no manguito do aparelho. J? os dados obtidos de maneira convencional est?o localizados em um monitor os quais tamb?m ser?o transferidos para o computador. Este trabalho n?o tem como objetivo realizar testes em seres humanos. Assim, para validar o sistema proposto, ser?o realizados testes em pacientes virtuais com uma amostragem de dez medidas para diferentes n?veis de press?o, tanto para o caso de pacientes adultos quanto para neonatais.
72

Efeitos das mudanças de discretização espacial no comportamento da vazão em sub-bacias

Venzon, Pedro Thiago, 1992-, Pinheiro, Adilson, 1961-, Kaufmann, Vander, 1979-, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Ambiental. January 2018 (has links) (PDF)
Orientador: Adilson Pinheiro. / Coorientador: Vander Kaufmann. / Dissertação (Mestrado em Engenharia Ambiental) - Programa de Pós-Graduação em Engenharia Ambiental, Centro de Ciências Tecnológicas, Universidade Regional de Blumenau, Blumenau.
73

Implantação de um programa de controle de qualidade em equipamentos de raios x por meio de medidores não invasivos / Establishment of an X radiation equipment quality control programme using non invasive meters

Rodrigo Ferreira de Lucena 14 September 2010 (has links)
O objetivo desse trabalho foi estudar o comportamento do principal equipamento de raios X utilizado nos procedimentos do laboratório de calibração do IPEN, LCI, operado nos intervalos de tensão de 25 a 150 kV utilizando os medidores de tensão não invasivos DiavoltTM da PTW e do sistema de espectrometria ORTEC, modelo NOMAD-PLUS 92X para o estabelecimento de um programa de controle de qualidade. O medidor Diavolt foi utilizado para as medições de kerma no ar, tensão de pico e tensão de pico prático. As medições foram feitas variando parâmetros como, corrente elétrica, Qualidade de Radiação X para Radiodiag-nóstico, angulação do medidor e sua distância em relação ao ponto focal do aparelho de raios X. Os resultados encontrados foram comparados com dados encontrados na literatura. Com o sistema de espectrometria, foram gerados os espectros com a finalidade de determinar as tensões de pico relativas às tensões nominais escolhidas e caracterizar as Qualidades em Radiodiagnóstico determinadas anteriormente. O programa de controle de qualidade estabelecido possibilita o controle do funcionamento tanto dos instrumentos de medição (câmaras de ionização, medidor de tensão e corrente e espectrômetro), bem como do sistema de radiação X. Neste trabalho também foi sugerida a periodicidade de realização de cada um dos testes. / The objective of this work was to study the behavior of the mainly X ray equipment calibration laboratory of IPEN, operated in the range from 25 kV to 150 kV using a PTW non invasive meter, model DiavoltTM, and an ORTEC spectrometry system, model NOMAD-PLUS 92X, for the establishment of a quality control programme. The Diavolt meter was used for measurements of air kerma, peak voltage and practical peak voltage. The measurements were made varying parameters such as electrical current, X radiation quality for radiation diagnostic, angulations of the meter and its distance in relation to the focal spot of the X ray tube. The results were compared with data found in the literature. Several spectra were generated with the spectrometer system with the purpose of determine the peak voltage in function of the nominal voltage and to characterize the radiation qualities for radiation diagnostic previously determined. The established quality control programme enables the management of the appropriate functioning of the measurement instruments (ionization chambers, voltage and current meter and spectrometer) as well as of the X radiation system. This work also has proposed a time interval to run each one of the tests.
74

A estratégia competitiva de uma empresa do sul do país no setor de medição de energia do mercado brasileiro

Silva, Hélio Lippert da 17 July 2007 (has links)
Made available in DSpace on 2015-03-05T18:38:00Z (GMT). No. of bitstreams: 0 Previous issue date: 17 / Nenhuma / O posicionamento competitivo é o tema central desta dissertação, que tem como objetivo a análise da estratégia empregada pela Elster, uma empresa localizada na Região Sul do Brasil, participante do grupo internacional CVC Partner, para se manter operando no mercado brasileiro de medição de energia. Como referencial teórico, utilizaram-se especialmente os conceitos de Porter (1986), segundo três dimensões: a estrutura da indústria, as estratégias genéricas e a estratégia corporativa. Para responder às questões formuladas pela pesquisa, empregou-se o método de estudo de caso. Com o avanço tecnológico, constatam-se modificações na indústria: o medidor mecânico, com uma tecnologia madura e predominante nas vendas, começou a ser substituído pelo medidor eletrônico. Antevê-se que as barreiras, antes protetoras da indústria, tendem a cair, oportunizando a entrada de novos participantes e o melhor posicionamento de algumas empresas já presentes no mercado. Até o momento, os ganhos da Elster advindos de seu pertencime / Competitive positioning is the core theme of this dissertation, which seeks to analyse the strategy employed by Elster, a business unit of the CVC Partner international corporation that is located in southern Brazil and operates in the Brazilian electricity metering industry. Concepts by Porter (1986) were adopted as theoretical framework, according to three dimensions: the industry’s structure, generic strategies and the corporate strategy. The case study approach was used to address questions raised in the research. It is evident that the industry has been undergoing changes; the mechanical electricity meter, with its consolidated technology and prevailing position in sales, is being replaced at large by the electronic meter. It is anticipated that protective barriers once existing in the industry are bound to collapse, paving the way for newcomers and for a better positioning of some companies that already have a standing in the segment. Until now the benefits Elster enjoyed in being part of an internation
75

Método para locação de medidores e UTRs para efeito de estimação de estados em sistemas elétricos de potência / not available

Brito, George Lauro Ribeiro de 15 October 2003 (has links)
Desenvolveu-se neste trabalho um método para projeto e fortalecimento de planos de medição, para efeito de estimação de estados. O método proposto permite a obtenção de planos de medição que além de isentos de medidas críticas e de conjuntos críticos de medidas, garantem a observabilidade do sistema, mesmo com a perda simultânea de 1 ou 2 medidas quaisquer, ou, até mesmo, com a perda de 1 UTR. É um método numérico simples, de fácil implantação, que se baseia na análise da estrutura da matriz resultante da decomposição LDU, que é obtida através da fatoração triangular da matriz Jacobiana. Para comprovar a sua eficiência, vários testes foram realizados, utilizando os sistemas de 14 e 30 barras do IEEE, o sistema de 121 barras da ELETROSUL e o sistema de 383 barras da CHESF. / In this work a method to design and to upgrade Measurements Placement Plan for state estimation is proposed. The proposed method allows the obtention of measurements placement plans that, besides free of both critical measurements and critical sets, maintain the system observability when 1 or 2 measurements are lost, at same time, or even when a Remote Terminal Unit (RTU) is lost. It is a simple numerical method, easy to implement and based on the analysis of the structure of the resultant matrix of the decomposition LDU, that it is obtained through a triangular factorization of the Jacobian matrix. To prove the efficiency of the proposed method, several tests were made using the IEEE 14 and 30-bus systems, a 121-bus system from ELETROSUL and a 383-bus system from CHESF.
76

Impactos da precipitação e do uso do solo nas tendências das vazões na bacia hidrográfica do Rio Grande / Impacts of precipitation and land use in the flow trends in the Grande river hydrographic basin

Santos, Cleber Assis dos 16 February 2018 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2018-04-25T18:28:52Z No. of bitstreams: 1 texto completo.pdf: 4679144 bytes, checksum: 5935358573b35d5d654bd90b3f0a8a29 (MD5) / Made available in DSpace on 2018-04-25T18:28:52Z (GMT). No. of bitstreams: 1 texto completo.pdf: 4679144 bytes, checksum: 5935358573b35d5d654bd90b3f0a8a29 (MD5) Previous issue date: 2018-02-16 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / As mudanças no clima associadas à variabilidade da precipitação e às alterações no uso e cobertura do solo consistem em importantes condicionantes da disponibilidade dos recursos hídricos pelo mundo, em especial das tendências no regime de vazões das bacias hidrográficas. O Brasil possui várias bacias hidrográficas de relevante importância econômica e social, dentre as quais, destaca-se a bacia hidrográfica do rio Grande (BHRG), afluente da margem esquerda do rio Paraná. Esta bacia localiza-se entre os estados de Minas Gerais e São Paulo, uma região estratégica do país, em que as atividades socioeconomicas têm papel relevante sobre a economia brasileira. O objetivo geral do presente trabalho foi analisar e caracterizar os impactos da precipitação e alterações do uso e cobertura do solo sobre as tendências temporais das vazões médias e mínimas de 12 áreas de drenagem da BHRG. Utilizaram-se dados de precipitação e vazão na área da BHRG, disponibilizados pela ANA (Agência Nacional de Águas), correspondentes ao período entre 1940 a 2010. Os dados de uso do solo foram provenientes do Grupo de Pesquisa em Interação Atmosfera-Biosfera da UFV. Aplicaram-se, nas séries de dados hidrológicos de cada área de drenagem, os testes estatísticos de Mann-Kendall (identificação da tendência), Pettitt (identificação do ponto de mudança) e Spearman rho (identificação da força de correlação entre duas variáveis). Também foram isolados os efeitos da precipitação sobre a vazão, através de um modelo chuva-vazão, por intermédio da curva de regressão tipo LOESS (Suavização de Dispersão Localmente Ponderada) entre o Índice de Precipitação Antecedente (API) e a vazão. Os resultados indicaram que, na maior parte da BHRG, entre 1940 e 2010, as vazões médias e mínimas (Q 7 ) apresentaram tendência de crescimento e que o principal responsável para a tendência de aumento nas vazões é a variabilidade natural da precipitação. As alterações de uso do solo apresentaram menor influência sobre as vazões. / Climate change associated with precipitation variability and land use and land cover changes are important determinants of the water availability in the world, especially of the trends in river flow regime. Brazil has several hydrographic basins with economic and social importance, including the BHRG (Grande River Hydrographic Basin), a tributary of the left bank of the Paraná River. This basin is located between the states of Minas Gerais and São Paulo, a strategic region of the country, where socioeconomic activities have a significant role in the Brazilian economy. The general objective of this work was to analyze and characterize the impacts of precipitation and land use and land cover changes on the temporal trends of medium and minimum flows of 12 drainage areas in the Grande river hydrographic basin. Precipitation and flow data from the BHRG area were used, made available by the National Water Agency (ANA), corresponding to the period between 1940 and 2010. Soil use data come from the Research Group on Atmosphere-Biosphere Interaction from the UFV. The statistical tests of Mann-Kendall (trend identification), Pettitt (point of change identification) and Spearman rho (identification of the correlation force between two variables) were applied in the hydrological data series of each drainage area. The effects of precipitation on flow were also isolated through a rain-flow model, using the LOESS regression curve (Locally Weighted Dispersion Smoothing) between API (Antecedent Precipitation Index) and flow. The results indicated that, in most of the BHRG, between 1940 and 2010, the medium and minimum flows (Q 7 ) presented growth trend and that the main responsible for the increasing trend in the flows is the natural variability of precipitation. The land-use changes had lower influence on flow rates. / Não foi localizado o currículo lattes do autor.
77

Modelagem dinâmica de transformadores de corrente para uso em estudos de qualidade da energia e proteção do sistema elétrico /

Borges, Fernando de Almeida. January 2014 (has links)
Orientador: José Alfredo Covolan Ulson / Banca: Rogério Andrade Faluzino / Banca: André Luiz Andreoli / Resumo: Os sistemas de proteção, medição e controle das concessionárias de energia elétrica utilizam transdutores eletromagnéticos de tensão e corrente para adequar as grandezas elétrica de interesse em níveis aceitáveis e necessários para relés de proteção e medidores de energia em geral. A não linearidade da corrente e a presença de frequências da fundamental provenientes de transitórios motivaram esse estudo, o qual buscou o entendimento e modelagem da função de transferência entre as correntes secundárias e primárias. Partindo do levantamento de dados em ensaios de laboratório de um transformador de corrente determinou-se a matriz admitância proposta, como modelo, em função da frequência e em seguida a função de transferência também como função da frequência utilizando o Algoritmo "Vector Fitting". Como resultado obteve-se uma função analítica que foi utilizada na estimação de correntes secundárias quando da aplicação de correntes primárias com frequências fundamental e múltiplas. O trablaho teve um resultado positivo em relação ao seu objetivo promovendo o levantamento do comportamento da relação entre as correntes primária e secundária e mostrando um método factível para a modelagem da resposta dos transformadores de corrente como função de frequência / Abstract: Protection systems, measurements and control of electric utilitiesuse electromagnetic transducers for voltage and current to match the electrical quantities at acceptable levels of interest and necessary for protection relays and power meters in general. The nonlinearity of the current and the presence of frequencies different from fundamental one arising from electrical transients motivated this study which sought the understanding and modeling of the transfer function between the primary and secondary currents. Based on the survey data in laboratory testing for a current transformer, admittance matrix model proposed as a function of frequency was determined, and then the transfer function also a function of frequency using Algorithm "Vector Fitting". As a result there was obtained and analytic function that was used in the estimation of secondary currents when applying primary currents at fundamental and multiple frequencies. The work had had a positive result in relation to its objective by promoting the survey of the behavior of the relationship between the primary and secondary currents and showing a feasible approach for modeling the response of Current Transformers as a function of frequency / Mestre
78

Sistema baseado em medidor de pressão diferencial para determinação em linha de vazões de produção em poços de petróleo. / System based on differential pressure device for in ine determination of production flow rate in oil wells.

Elson Francisco da Paz 17 December 2010 (has links)
A indústria de petróleo e gás tem trabalhado para o desenvolvimento de métodos que permitam o monitoramento e controle da produção de fluidos nos poços. Para isso são desenvolvidos equipamentos específicos para medição de vazões. Este trabalho apresenta um sistema baseado em medidores de vazão por obstrução ou pressão diferencial (placas de orifício, bocais e Venturis) para determinação em linha de vazões de produção (óleo, gás e água) em poços de petróleo. A partir das equações de conservação da massa e do momento para escoamento unidimensional e considerando escoamento isotérmico com fases incompressíveis, sem mudança de fase, com fases líquidas homogeneizadas e com escorregamento constante entre as fases líquida e gasosa, é deduzida uma relação geral entre vazão mássica total e queda de pressão. Utilizando a correlação de Chisholm para o escorregamento, é realizada uma comparação entre os resultados obtidos com o modelo homogêneo e o modelo de escorregamento constante. Por meio de uma caracterização dos fluidos em produção em estado permanente e utilizando o modelo de black oil para o sistema óleo-gás, são determinadas as vazões de produção na condição de referência. São realizadas validações dos resultados do modelo com dados experimentais obtidos numa bancada experimental em Aracaju (Sergipe) e em poços de Urucu (Amazonas). A comparação com os resultados experimentais mostra que as predições feitas com o modelo de escorregamento podem ser consideradas satisfatórias, levando-se em conta que o modelo foi desenvolvido de maneira independente, sem parâmetros de ajuste dos dados experimentais. / The oil and gas industry has been working to develop methods to monitor and control the fluid production in the wells. For this purpose, specific equipments are developed for measuring stream flows. This work presents a system based on differential pressure (or obstruction) flow meters (orifice plates, Venturis and nozzles) for online determination of production flows (oil, gas and water) in oil wells. Starting from the mass and momentum conservation equations for one-dimensional, isothermal flow and considering incompressible phases without phase change, homogenized liquid phases and constant slip between gas and liquid phases, a general relationship between total mass flow and pressure drop is derived. Using Chisholmts correlation for the slip, a comparison is made between the results obtained with the homogeneous model and the constant slip model. Through a characterization of the production fluids in steady state and using the black oil model for the oil-gas system, the production flows are determined at the reference condition. A validation is made between results obtained with the model and experimental data obtained in a rig at Aracaju (Sergipe) and in wells at Urucu (Amazonas). The comparison with experimental results shows that the predictions made with the slip model may be considered satisfactory, taking into account that the model was developed independently, without parameters adjusted from the experimental data.
79

Sistema baseado em medidor de pressão diferencial para determinação em linha de vazões de produção em poços de petróleo. / System based on differential pressure device for in ine determination of production flow rate in oil wells.

Paz, Elson Francisco da 17 December 2010 (has links)
A indústria de petróleo e gás tem trabalhado para o desenvolvimento de métodos que permitam o monitoramento e controle da produção de fluidos nos poços. Para isso são desenvolvidos equipamentos específicos para medição de vazões. Este trabalho apresenta um sistema baseado em medidores de vazão por obstrução ou pressão diferencial (placas de orifício, bocais e Venturis) para determinação em linha de vazões de produção (óleo, gás e água) em poços de petróleo. A partir das equações de conservação da massa e do momento para escoamento unidimensional e considerando escoamento isotérmico com fases incompressíveis, sem mudança de fase, com fases líquidas homogeneizadas e com escorregamento constante entre as fases líquida e gasosa, é deduzida uma relação geral entre vazão mássica total e queda de pressão. Utilizando a correlação de Chisholm para o escorregamento, é realizada uma comparação entre os resultados obtidos com o modelo homogêneo e o modelo de escorregamento constante. Por meio de uma caracterização dos fluidos em produção em estado permanente e utilizando o modelo de black oil para o sistema óleo-gás, são determinadas as vazões de produção na condição de referência. São realizadas validações dos resultados do modelo com dados experimentais obtidos numa bancada experimental em Aracaju (Sergipe) e em poços de Urucu (Amazonas). A comparação com os resultados experimentais mostra que as predições feitas com o modelo de escorregamento podem ser consideradas satisfatórias, levando-se em conta que o modelo foi desenvolvido de maneira independente, sem parâmetros de ajuste dos dados experimentais. / The oil and gas industry has been working to develop methods to monitor and control the fluid production in the wells. For this purpose, specific equipments are developed for measuring stream flows. This work presents a system based on differential pressure (or obstruction) flow meters (orifice plates, Venturis and nozzles) for online determination of production flows (oil, gas and water) in oil wells. Starting from the mass and momentum conservation equations for one-dimensional, isothermal flow and considering incompressible phases without phase change, homogenized liquid phases and constant slip between gas and liquid phases, a general relationship between total mass flow and pressure drop is derived. Using Chisholmts correlation for the slip, a comparison is made between the results obtained with the homogeneous model and the constant slip model. Through a characterization of the production fluids in steady state and using the black oil model for the oil-gas system, the production flows are determined at the reference condition. A validation is made between results obtained with the model and experimental data obtained in a rig at Aracaju (Sergipe) and in wells at Urucu (Amazonas). The comparison with experimental results shows that the predictions made with the slip model may be considered satisfactory, taking into account that the model was developed independently, without parameters adjusted from the experimental data.
80

Concepção de bancada para geração de condições conhecidas e controladas de vazão mássica de fluido de refrigeração

Martins, Erick Finzi January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnologico, Programa de Pós-Graduação em Engenharia Mecânica, Florianópolis, 2011 / Made available in DSpace on 2012-10-26T02:02:41Z (GMT). No. of bitstreams: 0 / Ensaios de desempenho de compressores de refrigeração são importantes para avaliar características energéticas do compressor, tais como capacidade de refrigeração e consumo. Essas características são indicadores de eficiência desses produtos. Os resultados desses ensaios são geralmente obtidos pela indústria através de bancadas específicas. Tais bancadas são produzidas utilizando conceitos e equipamentos semelhantes. Entretanto, possíveis desvios podem ocorrer na medição da capacidade de refrigeração de um compressor, quando esse é ensaiado em diferentes bancadas ou numa mesma bancada em momentos distintos. É usual a utilização de compressores amaciados para intercomparação e avaliação da deriva temporal das bancadas de ensaios de desempenho de compressores. Porém, existem algumas limitações no uso desses compressores específicos como padrões de capacidade de refrigeração. Os compressores padrões utilizados, como qualquer outro, sofrem desgastes naturais com o passar do tempo, gerando, assim, dúvidas quanto à fonte dos possíveis desvios de resultados detectados. Tais desvios podem ser devidos tanto à bancada de ensaio quanto ao próprio compressor padrão. Além disso, quando um compressor padrão se danifica a referência histórica é perdida. Este trabalho propõe o desenvolvimento de um conceito de padrão de capacidade de refrigeração. A capacidade de refrigeração, em condições preestabelecidas, é proporcional à vazão mássica do fluido de refrigeração. Sendo assim, o padrão proposto neste trabalho consiste basicamente de um medidor de vazão mássica e um compressor de capacidade variável cuja frequência rotacional é realimentada através da vazão mássica medida. Através dos resultados obtidos, em ensaios de controle de vazão mássica realizados em bancada desenvolvida para esse fim, foi possível validar o conceito de padrão de capacidade.

Page generated in 0.0855 seconds