• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 1
  • Tagged with
  • 10
  • 10
  • 6
  • 6
  • 6
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Switching Patterns and Steady-State Analysis of Grid-Connected and Stand-Alone Single-Stage Boost-Inverters for PV Applications

Saghaleini, Mahdi 08 November 2012 (has links)
Renewable or sustainable energy (SE) sources have attracted the attention of many countries because the power generated is environmentally friendly, and the sources are not subject to the instability of price and availability. This dissertation presents new trends in the DC-AC converters (inverters) used in renewable energy sources, particularly for photovoltaic (PV) energy systems. A review of the existing technologies is performed for both single-phase and three-phase systems, and the pros and cons of the best candidates are investigated. In many modern energy conversion systems, a DC voltage, which is provided from a SE source or energy storage device, must be boosted and converted to an AC voltage with a fixed amplitude and frequency. A novel switching pattern based on the concept of the conventional space-vector pulse-width-modulated (SVPWM) technique is developed for single-stage, boost-inverters using the topology of current source inverters (CSI). The six main switching states, and two zeros, with three switches conducting at any given instant in conventional SVPWM techniques are modified herein into three charging states and six discharging states with only two switches conducting at any given instant. The charging states are necessary in order to boost the DC input voltage. It is demonstrated that the CSI topology in conjunction with the developed switching pattern is capable of providing the required residential AC voltage from a low DC voltage of one PV panel at its rated power for both linear and nonlinear loads. In a micro-grid, the active and reactive power control and consequently voltage regulation is one of the main requirements. Therefore, the capability of the single-stage boost-inverter in controlling the active power and providing the reactive power is investigated. It is demonstrated that the injected active and reactive power can be independently controlled through two modulation indices introduced in the proposed switching algorithm. The system is capable of injecting a desirable level of reactive power, while the maximum power point tracking (MPPT) dictates the desirable active power. The developed switching pattern is experimentally verified through a laboratory scaled three-phase 200W boost-inverter for both grid-connected and stand-alone cases and the results are presented.
2

Using super capacitors to interface a small wind turbine to a grid-tied micro-inverter

Eldridge, Christopher Sean January 1900 (has links)
Master of Science / Department of Electrical Engineering / William B. Kuhn / During the development of an educational renewable energy production platform, it was found that there were no low-cost, efficient grid-tie interfaces for a 160 W DC wind turbine. Typically, a small DC wind turbine is used in conjunction with a rechargeable battery bank or, if the wind turbine is directly interfaced with a grid-tie inverter, a regulator with a diversion-load. The use of batteries is undesirable due to their high-cost and high-maintenance characteristics. Diversion loads by nature waste power, as any excess energy that cannot be accepted by a battery or inverter is usually converted into heat through a resistive element. Initially, a 24 V DC, 160 W Air Breeze small wind turbine was directly connected to an Enphase Energy M190 grid-tie micro-inverter. The 24 V DC Air Breeze wind turbine is designed to charge a battery or bank of batteries while the M190 micro-inverter is designed to convert the DC output of a 200 W solar panel to grid-tied AC power. As expected, the power-production response time associated with the small wind turbine and the power-accepting, load-matching response time of the micro-inverter were not compatible. The rapidly changing power output of the small wind turbine conflicted with the slow response time of the micro-inverter resulting in little power production. Ultimately, the response time mismatch also produced sufficiently large voltage spikes to damage the turbine electronics. In this thesis, a solution for a low-cost, efficient grid-tie interface using no batteries and no diversion load is presented. A capacitance of eight Farads is placed in parallel with the small wind turbine and the micro inverter. The large capacitance sufficiently smoothes the potential abrupt voltage changes produced by the wind turbine, allowing the micro-inverter adequate time to adjust its load for optimal power conversion. Laboratory experiments and data from an implementation of such a parallel super capacitor wind turbine to grid-tie micro-inverter configuration are provided along with DC and AC power production monitoring circuits interfaced with a micro controller.
3

Single Stage Grid-Connected Micro-Inverter for Photovoltaic Systems

SUKESH, NIKHIL 09 July 2012 (has links)
This thesis presents a novel Zero Voltage Switching (ZVS) approach in a grid connected single-stage flyback inverter without using any additional auxiliary circuits. The soft-switching of the primary switch is achieved by allowing negative current from the grid-side through bidirectional switches placed on the secondary side of the transformer. Basically, the negative current discharges the MOSFET’s output capacitor thereby allowing turn-on of the primary switch under zero voltage. In order to optimize the amount of reactive current required to achieve ZVS a variable frequency control scheme is implemented over the line cycle. In addition, the bi-directional switches on the secondary side of the transformer have ZVS during the turn-on times. Therefore, the switching losses of the bi-directional switches are negligible. A 250W prototype has been implemented in order to validate the proposed scheme. Experimental results confirm the feasibility and superior performance of the converter compared to the conventional flyback inverter. / Thesis (Master, Electrical & Computer Engineering) -- Queen's University, 2012-07-06 16:24:13.385
4

Investigation of Dual-Stage High Efficiency and Density Micro Inverter for Solar Application

Chen, Lin 01 January 2014 (has links)
Module integrated converters (MIC), also called micro inverter, in single phase have witnessed recent market success due to unique features (1) improved energy harvest, (2) improved system efficiency, (3) lower installation costs, (4) plug-N-play operation, (5) and enhanced flexibility and modularity. The MIC sector has grown from a niche market to mainstream, especially in the United States. Due to the fact that two-stage architecture is commonly used for single phase MIC application. A DC-DC stage with maximum power point tracking to boost the output voltage of the Photovoltaic (PV) panel is employed in the first stage, DC-AC stage is used for use to connect the grid or the residential application. As well known, the cost of MIC is key issue compared to convention PV system, such as the architecture: string inverter or central inverter. A high efficiency and density DC-DC converter is proposed and dedicated for MIC application. Assuming further expansion of the MIC market, this dissertation presents the micro-inverter concept incorporated in large size PV installations such as MW-class solar farms where a three phase AC connection is employed. A high efficiency three phase MIC with two-stage ZVS operation for grid tied photovoltaic system is proposed which will reduce cost per watt, improve reliability, and increase scalability of MW-class solar farms through the development of new solar farm system architectures. This dissertation presents modeling and triple-loop control for a high efficiency three-phase four-wire inverter for use in grid-connected two-stage micro inverter applications. An average signal model based on a synchronous rotation frame for a three-phase four-wire inverter has been developed. The inner current loop consists of a variable frequency bidirectional current mode (VFBCM) controller which regulates output filter inductor current thereby achieving ZVS, improved system response, and reduced grid current THD. Active damping of the LCL output filter using filter inductor current feedback is discussed along with small signal modeling of the proposed control method. Since the DC-link capacitor plays a critical role in two-stage micro inverter applications, a DC-link controller is implemented outside of the two current control loops to keep the bus voltage constant. In the end, simulation and experimental results from a 400 watt prototype are presented to verify the validity of the theoretical analysis.
5

Optimization And Design Of Photovoltaic Micro-inverter

Zhang, Qian 01 January 2013 (has links)
To relieve energy shortage and environmental pollution issues, renewable energy, especially PV energy has developed rapidly in the last decade. The micro-inverter systems, with advantages in dedicated PV power harvest, flexible system size, simple installation, and enhanced safety characteristics are the future development trend of the PV power generation systems. The double-stage structure which can realize high efficiency with nice regulated sinusoidal waveforms is the mainstream for the micro-inverter. This thesis studied a double stage micro-inverter system. Considering the intermittent nature of PV power, a PFC was analyzed to provide additional electrical power to the system. When the solar power is less than the load required, PFC can drag power from the utility grid. In the double stage micro-inverter, the DC/DC stage was realized by a LLC converter, which could realize soft switching automatically under frequency modulation. However it has a complicated relationship between voltage gain and load. Thus conventional variable step P&O MPPT techniques for PWM converter were no longer suitable for the LLC converter. To solve this problem, a novel MPPT was proposed to track MPP efficiently. Simulation and experimental results verified the effectiveness of the proposed MPPT. The DC/AC stage of the micro-inverter was realized by a BCM inverter. With duty cycle and frequency modulation, ZVS was achieved through controlling the inductor current bi-directional in every switching cycle. This technique required no additional resonant components and could be employed for low power applications on conventional full-bridge and half-bridge inverter topologies. Three different current mode control schemes were derived from the basic theory of the proposed technique. They were referred to as Boundary Current Mode (BCM), Variable Hysteresis Current Mode (VHCM), and Constant Hysteresis Current Mode (CHCM) individually in this paper with their advantages and disadvantages analyzed in detail. Simulation and experimental iv results demonstrated the feasibilities of the proposed soft-switching technique with the digital control schemes. The PFC converter was applied by a single stage Biflyback topology, which combined the advantages of single stage PFC and flyback topology together, with further advantages in low intermediate bus voltage and current stresses. A digital controller without current sampling requirement was proposed based on the specific topology. To reduce the voltage spike caused by the leakage inductor, a novel snubber cell combining soft switching technique with snubber technique together was proposed. Simulation and experimental waveforms illustrated the same as characteristics as the theoretical analysis. In summary, the dissertation analyzed each power stage of photovoltaic micro-inverter system from efficiency and effectiveness optimization perspectives. Moreover their advantages were compared carefully with existed topologies and control techniques. Simulation and experiment results were provided to support the theoretical analysis.
6

Control Based Soft Switching Three-phase Micro-inverter: Efficiency And Power Density Optimization

Amirahmadi, Ahmadreza 01 January 2014 (has links)
In the field of renewable energy, solar photovoltaic is growing exponentially. Grid-tied PV micro-inverters have become the trend for future PV system development because of their remarkable advantages such as enhanced energy production due to MPPT implementation for each PV panel, high reliability due to redundant and distributed system architecture, and simple design, installation, and management due to its plug-and-play feature. Conventional approaches for the PV micro-inverters are mainly in the form of single-phase grid connected and they aim at the residential and commercial rooftop applications. It would be advantageous to extend the micro-inverter concept to large size PV installations such as MW-class solar farms where threephase AC connections are used. The relatively high cost of the three-phase micro-inverter is the biggest barrier to its large scale deployment. Increasing the switching frequency may be the best way to reduce cost by shrinking the size of reactive components and heat-sink. However, this approach could cause conversion efficiency to drop dramatically without employing soft switching techniques or using costly new devices. This dissertation presents a new zero voltage switching control method that is suitable for low power applications such as three-phase micro-inverters. The proposed hybrid boundary conduction mode (BCM) current control method increases the efficiency and power density of the micro-inverters and features both reduced number of components and easy digital implementation. Zero voltage switching is achieved by controlling the inductor current bidirectional in every switching cycle and results in lower switching losses, higher operating frequency, and reduced size and cost of passive components, especially magnetic cores. Some iv practical aspects of hybrid control implementation such as dead-time insertion can degrade the performance of the micro-inverter. A dead-time compensation method that improves the performance of hybrid BCM current control by decreasing the output current THD and reducing the zero crossing distortion is presented. Different BCM ZVS current control modulation schemes are compared based on power losses breakdown, switching frequency range, and current quality. Compared to continuous conduction mode (CCM) current control, BCM ZVS control decreases MOSFET switching losses and filter inductor conduction losses but increases MOSFET conduction losses and inductor core losses. Based on the loss analysis, a dual-mode current modulation method combining ZVS and zero current switching (ZCS) schemes is proposed to improve the efficiency of the micro-inverter. Finally, a method of maintaining high power conversion efficiency across the entire load range of the three-phase micro-inverter is proposed. The proposed control method substantially increases the conversion efficiency at light loads by minimizing switching losses of semiconductor devices as well as core losses of magnetic components. This is accomplished by entering a phase skipping operating mode wherein two phases of an inverter are disabled and three inverters are combined to form a new three-phase system with minimal grid imbalance. A 400W prototype of a three-phase micro-inverter and its hybrid control system have been designed and tested under different conditions to verify the effectiveness of the proposed controller, current modulation scheme, and light load efficiency enhancement method.
7

Flyback photovoltaic micro-inverter with a low cost and simple digital-analog control scheme

Yaqoob, S.J., Obed, A., Zubo, R., Al-Yasir, Yasir I.A., Fadhel, H., Mokryani, Geev, Abd-Alhameed, Raed 04 August 2021 (has links)
Yes / The single-stage flyback Photovoltaic (PV) micro-inverter is considered as a simple and small in size topology but requires expensive digital microcontrollers such as Field-Programmable Gate Array (FPGA) or Digital Signal Processor (DSP) to increase the system efficiency, this would increase the cost of the overall system. To solve this problem, based on a single-stage flyback structure, this paper proposed a low cost and simple analog-digital control scheme. This control scheme is implemented using a low cost ATMega microcontroller built in the Arduino Uno board and some analog operational amplifiers. First, the single-stage flyback topology is analyzed theoretically and then the design consideration is obtained. Second, a 120 W prototype was developed in the laboratory to validate the proposed control. To prove the effectiveness of this control, we compared the cost price, overall system efficiency, and THD values of the proposed results with the results obtained by the literature. So, a low system component, single power stage, cheap control scheme, and decent efficiency are achieved by the proposed system. Finally, the experimental results present that the proposed system has a maximum efficiency of 91%, with good values of the total harmonic distortion (THD) compared to the results of other authors / This work was supported in-part by Innovate UK GCRF Energy Catalyst PiCREST project under Grant number 41358, in-part by British Academy GCRF COMPENSE project under Grant GCRFNGR3\1541
8

SolarBridge Technologies: Entrepreneurship in the Solar Inverter Industry

Blair, Daniel P. 25 April 2011 (has links)
No description available.
9

Design Optimization Of Llc Topology And Phase Skipping Control Of Three Phase Inverter For Pv Applications

Somani, Utsav 01 January 2013 (has links)
The world is heading towards an energy crisis and desperate efforts are being made to find an alternative, reliable and clean source of energy. Solar Energy is one of the most clean and reliable source of renewable energy on earth. Conventionally, extraction of solar power for electricity generation was limited to PV farms, however lately Distributed Generation form of Solar Power has emerged in the form of residential and commercial Grid Tied Micro-Inverters. Grid Tied Micro-Inverters are costly when compared to their string type counterparts because one inverter module is required for every single or every two PV panels whereas a string type micro-inverter utilizes a single inverter module over a string of PV panels. Since in micro-inverter every panel has a dedicated inverter module, more power per panel can be extracted by performing optimal maximum power tracking over single panel rather than over an entire string of panels. Power per panel extracted by string inverters may be lower than its maximum value as few of the panels in the string may or may not be shaded and thereby forming the weaker links of the system. In order to justify the higher costs of Micro-Inverters, it is of utmost importance to convert the available power with maximum possible efficiency. Typically, a microinverter consists of two important blocks; a Front End DC-DC Converter and Output DCAC Inverter. This thesis proposes efficiency optimization techniques for both the blocks of the micro-inverter. iv Efficiency Optimization of Front End DC-DC Converter This thesis aims to optimize the efficiency of the front end stage by proposing optimal design procedure for resonant parameters of LLC Topology as a Front End DC-DC Converter for PV Applications. It exploits the I-V characteristics of a solar panel to design the resonant parameters such that resonant LLC topology operates near its resonant frequency operating point which is the highest efficiency operating point of LLC Converter. Efficiency Optimization of Output DC-AC Inverter Due to continuously variable irradiance levels of solar energy, available power for extraction is constantly varying which causes the PV Inverter operates at its peak load capacity for less than 15% of the day time. Every typical power converter suffers through poor light load efficiency performance because of the load independent losses present in a power converter. In order to improve the light load efficiency performance of Three Phase Inverters, this thesis proposes Phase Skipping Control technique for Three Phase Grid Tied Micro-Inverters. The proposed technique is a generic control technique and can be applied to any inverter topology, however, in order to establish the proof of concept this control technique has been implemented on Three Phase Half Bridge PWM Inverter and its analysis is provided. Improving light load efficiency helps to improve the CEC efficiency of the inverter.
10

Contribution to the DC-AC conversion in photovoltaic systems : Module oriented converters / Contribution à l’étude de la conversion DC-AC dans des systèmes photovoltaïques : Convertisseurs orientés au module PV

Lopez Santos, Oswaldo 06 February 2015 (has links)
Ces dernières années, un intérêt croissant pour les systèmes électroniques de puissance a été motivé par l'émergence de sources d'énergie distribuées et renouvelables raccordées aux réseaux électriques. Dans ce contexte, la nécessité de topologies de faibles puissances alimentées par quelques modules photovoltaïques, en évitant l'utilisation de transformateurs, a ouvert l'étude de convertisseurs spéciaux et l’étude des stratégies de commande associées afin d’assurer la stabilité, la fiabilité et un rendement élevé du dispositif. Une possible solution est d’utiliser un dispositif générique connu dans la littérature scientifique et commerciale comme « micro-onduleur » ou «convertisseur intégré au module » qui avec le module photovoltaïque définit un produit « plug and play » appelé "module AC".Ce travail est consacré à l'étude d'un micro-onduleur monophasé avec deux étapes sans transformateur raccordée au réseau. La topologie proposée est composé d’un convertisseur DC-DC non isolé élévateur avec un gain quadratique et un onduleur réducteur lié au réseau connectés en cascade. Le convertisseur DC-DC extrait en permanence la puissance maximale du module photovoltaïque malgré les changements dans les conditions environnementales. L'étape DC-AC injecte la puissance extraite par l'étape DC-DC dans le réseau et assure un niveau élevé de qualité de l’énergie. Les efforts de recherche de ce travail sont concentrés sur la mise au point de commandes utilisant comment base, la théorie de contrôle par mode de glissement, qui conduit à une mise en œuvre simple avec une description théorique complète validée á partir de simulations et expérimentations.Après avoir décrit l'état de l’art dans le premier chapitre, le manuscrit est divisé en quatre chapitres, qui sont dédiés respectivement à l’algorithme de recherche du point de puissance maximale (MPPT), á l’étape de conversion DC-DC, á l'étape de conversion DC-AC et finalement au micro-onduleur complet. Un nouvel algorithme de recherche extrémal du point de puissance maximale est développé (SM-ESC). Pour la étape DC-DC, le convertisseur élévateur quadratique avec seulement un interrupteur contrôlé est étudié utilisant le concept de résistance sans perte par mode de glissement (de l’acronyme anglais : Sliding-Mode Loss-Free-Resistor – SM-LFR) afin d’obtenir un gain de tension élevé avec un fonctionnement sûr et compatible avec l’algorithme MPPT. Pour la étape DC-AC, le convertisseur de pont complet est contrôlé comme un onduleur de source de puissance (de l’acronyme anglais : Power Source Inverter - PSI) en utilisant une commande par mode de glissement qui poursuit une référence sinusoïdale de courant de sortie. Cette commande est complétée par une boucle de régulation de la tension du bus DC qui assure une haute qualité d’énergie injectée dans le réseau. Enfin, les trois étapes constitutives sont fusionnées pour obtenir un micro-onduleur complètement contrôlé par la technique de mode de glissement, ce qui constitue le principal résultat et contribution de cette thèse. / These last years, a growing interest in power electronic systems has been motivated by the emergence of distributed renewable energy resources and their interconnection with the grid. In this context, the need of low power topologies fed by a few photovoltaic modules avoiding the use of transformers opens the study of special converters and the associated control strategies ensuring stability, reliability and high efficiency. A resulted generic device known in the commercial and scientific literature as “microinverter” or “module integrated converter” performs a plug and play product together with the PV module called an “AC module”.This work is devoted to the study of a transformer-less single-phase double-stage grid-connected microinverter. The proposed topology has a non-isolated high-gain boost type DC-DC converter and a non-isolated buck type DC-AC converter connected in cascade through a DC bus. The DC-DC converter permanently extracts the maximum power of the PV module ensuring at the same time a good performance coping with power changes introduced by the change in the environmental conditions. The DC-AC stage injects the power extracted by the DC-DC stage into the grid ensuring a high level of power quality. The research efforts focus on the involved control functions based on the sliding mode control theory, which leads to a simple implementation with a comprehensive theoretical description validated through simulation and experimental results.After giving the state-of-the-art in the first chapter, the manuscript is divided into four chapters, which are dedicated to the Maximum Power Point Tracking (MPPT), the DC-DC stage and its control, the DC-AC stage and its control and the complete microinverter. A new Extremum Seeking Control (ESC) MPPT algorithm is proposed. The single-switch quadratic boost converter is studied operating as a Loss-Free-Resistor (LFR) obtaining a high DC output voltage level with a safe operation. The full-bridge converter is controlled as a Power Source Inverter (PSI) using a simple sliding-mode based tracking law, regulating the voltage of the DC bus and then ensuring a high power quality level in the grid connection. Finally, the three building blocks are merged to obtain a sliding mode controlled microinverter constituting the main result and contribution of the work

Page generated in 0.0877 seconds