Spelling suggestions: "subject:"microelectro mechanical system"" "subject:"microelectron mechanical system""
1 |
Hierarchical Optical Path Cross-Connect Node Architecture Using WSS/WBSSMitsui, Shin-ichi, Hasegawa, Hiroshi, Sato, Ken-ichi 08 1900 (has links)
No description available.
|
2 |
Low loss and cost-effective hierarchical optical path cross-connect switch architecture based on WSS/WBSSMitsui, Shin-ichi, Hasegawa, Hiroshi, Sato, Ken-ichi 15 September 2009 (has links)
No description available.
|
3 |
Development of an Innovative Micro Capacitive Humidity Sensor with Double Polyimide Thin Films and Interlacing Out-of-plane ElectrodesLi, Yao-Yu 21 July 2006 (has links)
Polyimide thin films have been widely used in microelectronic and Micro-Electro-Mechanical System applications due to their many excellent characteristics including low dielectric constant, easy processing, good step coverage ability, high heat resistance and chemical resistance.
This paper presents the design, fabrication and complete characterization of an innovative capacitive relative humidity (RH) microsensor. The double polyimide thin films adopted in this study function as a capacitance sensing layer and a protecting layer of top electrodes respectively. To improve the humidity sensitivity and responding speed, interlacing out-of-plane electrodes are designed in the RH microsensor. The higher sensitivity ( 1.25 pF/¢HRH ), optimized sensing linearity ( 99.968¢H ) , very low hysteresis ( 0.24 ¢HRH ), excellent stability ( 1.36 ¢HRH ) , high accuracy ( ¡Ó 1.12 ¢HRH ) and fast response ( within 1 seconds ) characteristics of the RH microsensor have been demonstrated in this thesis.
|
4 |
Μοντελοποίηση ηλεκτρομηχανικών διατάξεων μικρής κλίμακαςΛακιώτη, Άννα 04 October 2011 (has links)
Οι ηλεκτρομηχανικές συσκευές αποθήκευσης δεδομένων πολύ μικρής κλίμακας που βασίζονται στη χρήση ακίδων (probes) αποτελούν ανερχόμενες εναλλακτικές επιλογές για τη βελτίωση της πυκνότητας αποθήκευσης, του χρόνου πρόσβασης των δεδομένων και της απαιτούμενης ισχύος σε σχέση με τις συμβατικές συσκευές αποθήκευσης. Μία υλοποίηση μιας τέτοιας συσκευής χρησιμοποιεί θερμομηχανικές μεθόδους για την αποθήκευση πληροφορίας σε λεπτές μεμβράνες πολυμερών υλικών. Στην περίπτωση αυτή, η ψηφιακή πληροφορία αποθηκεύεται με τη μορφή κοιλωμάτων πάνω στο πολυμερές υλικό, τα οποία δημιουργούνται από τις ακίδες, διαμέτρου μερικών nm. Με στόχο την αύξηση του ρυθμού εγγραφής και ανάγνωσης χρησιμοποιούνται δισδιάστατες διατάξεις από ακίδες που λειτουργούν παράλληλα, με κάθε ακίδα να εκτελεί λειτουργίες εγγραφής /ανάγνωσης /διαγραφής σε ξεχωριστό αποθηκευτικό πεδίο.
Η μετατόπιση του αποθηκευτικού μέσου σε σχέση με τη διάταξη των ακίδων επιτυγχάνεται με τη χρησιμοποίηση ηλεκτρομηχανικού συστήματος μικρής κλίμακας (MEMS). Η διάταξη MEMS αποτελείται από ένα μικρής κλίμακας σύστημα σάρωσης (microscanner) και από το τσιπ της δισδιάστατης διάταξης των ακίδων. Το σύστημα σάρωσης έχει δυνατότητα κίνησης σε δύο διευθύνσεις (x/y).
Αντικείμενο της διπλωματικής εργασίας είναι η μοντελοποίηση του συστήματος σάρωσης μικρής κλίμακας. Η μοντελοποίηση του συστήματος έγινε με βάση το σύστημα του απλού αρμονικού ταλαντωτή με απόσβεση. Στα πλαίσια της εργασίας μελετάται η απόκριση του συστήματος σε διάφορους τύπους διεγέρσεων, ενώ για την προσομοίωση της συμπεριφοράς του microscanner αναπτύχθηκε εφαρμογή στην γλώσσα προγραμματισμού Visual Basic. Η εφαρμογή περιλαμβάνει γραφικό περιβάλλον με δυνατότητα ρύθμισης των παραμέτρων εξομοίωσης. / Micro-electro-mechanical-system (MEMS)-based scanning-probe storage devices are emerging as potential ultra-high-density, low-access-time, and low-power alternatives to conventional data storage. One implementation of probe-based storage uses thermomechanical means to store and retrieve information in thin polymer films. Digital information is stored by making indentations on the thin polymer film with the tips of atomic force microscope (AFM) cantilevers, which are a few nanometers in diameter. To increase the data rate, an array of probes is used, in which each probe performs read/ write/ erase operations over an individual storage field.
Displacement of the storage medium relative to the array of cantilevers is achieved by using micro-electro-mechanical-system (MEMS). The MEMS assembly consists of the microscanner and the cantilever array chip. The microscanner with x and y motion range carries the storage medium.
This diploma dissertation presents the modeling of the microscanner. The system models as a damped harmonic oscillator. The model response on different driven forces has been studied, whereas an application in Visual Basic has been generated to simulate the system motion. The application comprises graphic interface with simulation parameters modulation.
|
5 |
Conception, fabrication et caractérisation d'un microphone MEMS / Conception, fabrication and characterization of a MEMS microphoneCzarny, Jaroslaw 27 January 2015 (has links)
Les microphones à électret dédiés à l'électronique grand public et les applications médicales (les audioprothèses) ont atteint les limites de la miniaturisation. Depuis la sortie du premier microphone basé sur une technologie microsystème sur silicium (MEMS: Micro-Electro-Mechanical Systems), les microphones à électret sont progressivement remplacés par les microphones MEMS. Les MEMS utilisent le silicium car il offre des caractéristiques mécaniques exceptionnelles avec de bonnes propriétés électriques et la technologie de fabrication est maintenant bien maîtrisée. La plupart des microphones MEMS qui sont décrits dans la littérature sont constitués d’une membrane qui vibre en dehors du plan du capteur, et utilisent la transduction capacitive. La miniaturisation de tels microphones est limitée car leur sensibilité est liée à la valeur de la capacité qui dépend de la taille de la membrane. En outre, les capteurs capacitifs sont très sensibles aux capacités parasites et aux non-linéarités. Cette thèse présente une nouvelle architecture de microphone MEMS qui utilise des micro-poutres qui vibrent dans le plan capteur. La transduction du signal est réalisée par des nanojauges piézorésistives intégrées dans le microsystème et attachées aux micro-poutres. Ce système de détection original ne présente pas les inconvénients de la détection capacitive et à la différence des piézorésistors classiques intégrés dans la membrane de silicium, les nanofils suspendus permettent d’éliminer les courants de fuite. De plus, l'amélioration de la détection est possible puisque le coefficient piézo-résistif longitudinal est inversement proportionnel à la section du nanofil. Les fluctuations de pression acoustique entraînent les déviations des micro-poutres qui produisent une concentration de contraintes dans les nanogauges. Le comportement du capteur, que l’on cherche à modéliser, est lié à des phénomènes mécaniques, acoustiques et électriques qui sont couplés. En raison des dimensions micrométriques du MEMS, les effets des dissipations thermique et visqueuse doivent être pris en compte dans le comportement acoustique. Pour prédire de façon fiable le comportement du capteur, deux modèles vibroacoustiques sont utilisés: un modèle éléments finis basé sur l'ensemble des équations de Navier-Stokes linéarisées et un modèle approché basé sur un schéma à constantes localisées (représentation par circuit électrique équivalent). Les deux modèles sont complémentaires dans le processus de conception pour déterminer la réponse en fréquence et le taux de bruit du capteur. Le travail est complété par la description des processus technologiques et les défis liés à la fabrication du prototype. Puis deux approches pour la caractérisation fonctionnelle du microphone MEMS sont présentées, la première en tube d’impédance, la seconde en champ libre. / Electret microphones dedicated to consumer electronics and medical applications (hearing aids) have reached the miniaturization limits. Since the release of the first microphone based on Silicon micromachining, electret microphones are constantly replaced by MEMS microphones. MEMS (Micro-Electro-Mechanical Systems) microphones use Silicon that provides exceptional mechanical characteristics along with good electric properties and mature fabrication technology. Regardless of the transduction principle (capacitive, piezoresistive, piezoelectric, optical), all of the MEMS microphones reported in the state of the art literature are based on a membrane deflecting out of the plane of the base wafer. Most of the reported microphones and all of the commercially available MEMS use capacitive transduction. Downscaling of capacitive microphones is problematic, since the sensitivity depends on capacitance value. Moreover capacitive sensors suffer of high sensitivity to parasitic capacitance and nonlinearity. The drawbacks of capacitive detection may be overcome with use of piezoresistive properties of Silicon nanowires. Unlike the classical piezoresistors integrated into silicon membrane, suspended nanowires do not suffer of leakage current. Further improvement of piezoresistive detection is possible since the longitudinal piezoresistive coefficient rises inversely proportional to nanowire section. This thesis presents the considerations of novel MEMS microphone architecture that uses microbeams which deflect in the plane of the base wafer. Signal transduction is achieved by piezoresistive nanogauges integrated in the microsystem and attached to the microbeams. Acoustic pressure fluctuations lead to the deflection of the microbeams which produces a stress concentration in the nanogauges. Accurate simulations of the discussed transducer couple acoustic, mechanical and electric behavior of the system. Due to micrometric dimensions of the MEMS acoustic system, thermal and viscous dissipative effects have to be taken into account. To reliably predict the sensor behavior two acoustic models are prepared: the complete Finite Element Model based on the full set of linearized Navier-Stokes equations and the approximative model based on the Lumped Elements (Equivalent Cirtuit Representation). Both models are complementary in the design process to finally retrieve the frequency response and the noise budget of the sensor. The work is completed by the description of the technological process and the challenges related to the prototype microfabrication. Then the approach to the MEMS microphone characterization in pressure-field and free-field is presented.
|
6 |
Biocapteurs implantables pour un monitorage intracérébral minimalement invasif / Implantable biosensors for minimally invasive intracerebral monitoringChatard, Charles 23 November 2018 (has links)
Le fonctionnement du cerveau repose sur la libération de molécules telles que les neurotransmetteurs et les métabolites dans le milieu interstitiel. L’étude de ces molécules est donc primordiale afin de mieux comprendre leur rôle physiologique et pathologique. Pour cela, les biocapteurs enzymatiques implantables sont un outil prometteur de par leurs capacités de détection quantitative, en temps réel et dans les tissus profonds. En fonction des dimensions du biocapteur, l’impact de l’implantation peut avoir des conséquences considérables sur la composition chimique du fluide interstitiel. De plus, chaque implantation induit localement une réaction inflammatoire dite « réaction au corps étranger ». La réduction de ces réactions est indispensable afin d’obtenir des estimations plus précises de la concentration des molécules présentes. Dans ce sens, ce manuscrit exposera deux voies de réduction de l’impact lésionnel dû à l’implantation de biocapteurs. Tout d’abord, il sera présenté la miniaturisation de biocapteurs enzymatiques jusqu’à des diamètres externes inférieurs à 15 µm. Et il sera démontré in vivo que ces biocapteurs ultra miniaturisés ont le potentiel d’être implantés dans le cerveau sans induire de dommages détectables aux tissus et aux vaisseaux sanguins. Ensuite, le développement d’une microsonde fabriquée à l’aide des technologies MEMS couplant une détection électrochimique et optique sera introduit dans le cadre du suivi du fluide interstitiel péri- et intratumoral de glioblastomes modifiés pour émettre de la fluorescence. En intégrant deux types de détection sur une unique micro-aiguille, cette microsonde permet de réduire le nombre d’implantations. Ces deux voies de miniaturisation ouvrent la possibilité de suivre la composition chimique du fluide interstitiel de manière moins invasive, et donc de mieux préserver la physiologie des tissus étudiés dans le cerveau. / Brain function is based on the release of molecules such as neurotransmitters and metabolites into the interstitial fluid. The study of these molecules is essential to better understand their physiological and pathological role. For this purpose, implantable enzymatic biosensors are a promising tool because of their quantitative, real-time and deep tissue detection abilities. Depending on the dimensions of the biosensor, the impact of implantation may have considerable consequences on the chemical composition of the interstitial fluid. In addition, each implantation induces a local inflammatory reaction called "foreign body reaction". The reduction of these reactions is crucial in order to provide more accurate estimations of molecules concentrations present in the interstitial fluid. In this sense, this manuscript will expose two ways of reducing the lesional impact due to the implantation of biosensors. First of all, it will be presented the miniaturization of enzymatic biosensors up to external diameters less than 15 µm. And it will be demonstrated in vivo that these ultra miniaturized biosensors have the potential to be implanted in the brain without inducing detectable damage to tissues and blood vessels. Then, the development of a microprobe fabricated using MEMS technologies combining electrochemical and optical detection will be introduced as part of the monitoring of peri- and intratumoral interstitial fluid from glioblastomes modified to fluoresce. By integrating two types of detection on a single micro-needle, this microprobe reduces the number of implantations. These two miniaturization approaches open up the possibility of following the chemical composition of the interstitial fluid in a less invasive way, and thus of better preserving the physiology of the tissues studied in the brain.
|
7 |
Miniature laser scanning micro-endoscopes : multi-modality imaging system and biomedical applicationsWang, Youmin, 1986- 15 July 2013 (has links)
Cancer is a world menace. After years of endeavor seeking the end of it, people started to realize that no matter how powerful the therapy could be, detection at early stage is always a cheaper, easier and more successful solution compared with curative methods for cancer developed onto its advanced stage. However, relatively few early-detection approaches have proven sufficiently effective and practical for mass use as a point-of-care tool. An early-cancer screening tool integrating the desired features of sensitive, informative, portable, and cost-effective is in need for the doctors.
The progress in optical imaging and Micro-electro-mechanical system (MEMS) technology offers a promise for an innovative cancer screening alternative that is non-invasive, radiation-free, portable and potentially cost-effective. This dissertation investigates handheld instrumentation as multi-modalities of miniature imaging probes with various designs of MEMS devices, to obtain real-time images of epithelial tissue optical and physiological properties, combining the quantitative advantages of spectral analysis with the qualitative benefits of imaging to distinguish early cancer. This dissertation in sequence presents the handheld instruments in the fashions of Laser-scanning confocal microscopy (LSCM), optical diffuse reflectance imaging, nonlinear optical imaging modalities with their subsequent image-guided managements in oral cancer, skin cancer detection, circulating tumor cell (CTC) imaging, and imaging guided surgeries.
One of the main challenges facing miniaturization lies in the mechanism of beam deflection across the sample. This dissertation introduces two generations of MEMS devices desgined, fabricated and incorporated in the imaging probes. A two-axis vertical comb driven silicon micromirror was used in the development of a handheld LSCM for oral cancer detection. Though obtaining numerous advantages, this first generation silicon MEMS micromirror suffers from small aperture size and high voltage requirement for actuation, which result in low collection efficiency in fluorescence imaging and medial safety concerns, respectively. Therefore a stainless steel scanner compatible with electrical discharge machining (EDM) process was fabricated with simplified process, low-voltage magnetic actuation and large fluorescence collection efficiency, with its capability demonstrated in the incorporation and embodiment of a handheld hyperspectral nonlinear imaging probe.
Besides, software and controlling innovations for handheld imaging modalities are presented. A feedback controlling system for MEMS scanning status monitoring was developed for stabilized imaging rendering. For the sake of further improved imaging stability in handheld imaging and to enable on-site mosaic for large field viewing, a handheld mosaic system was developed and presented. / text
|
8 |
Pupil Tracking and Control of a Laser Based Power System for a Vision Restoring Retinal ImplantMailhot, Nathaniel 17 January 2019 (has links)
For elderly Canadians, the prevalence of vision impairment caused by degenerative
retinal pathologies, such as age-related macular degeneration and retinitis
pigmentosa, is at an occurrence rate of 14 percent, and on the rise. It has been
shown that visual function can be restored by electrically stimulating intact retinal
tissue with an array of micro-electrodes with suitable signals. Commercial retinal
implants carrying such a micro-electrode array achieve this, but to date must
receive power and data over copper wire cable passing through a permanent surgical
incision in the eye wall (sclera). This project is defined by a collaboration
with iBIONICS, who are developing retinal implants for treatment of such conditions.
iBIONICS has developed the Diamond Eye retinal implant, along with
several technology sub-systems to form a comprehensive and viable medical solution.
Notably, the Diamond Eye system can be powered wirelessly, with no need
for a permanent surgical incision.
The thesis work is focused on the formulation, simulation and hardware demonstration
of a powering system, mounted on glasses frame, for a retinal implant.
The system includes a Micro-Electro-Mechanical System (MEMS) mirror that directs
a laser beam to the implant through the pupil opening. The work presented
here is built on two main components: an iterative predictor-corrector algorithm
(Kalman filter) that estimates pupil coordinates from measurements provided by
an image-based eye tracking algorithm; and an misalignment compensation algorithm
that maps eye pupil coordinates into mirror coordinates, and compensates
for misalignment caused by rigid body motions of the glasses lens mirror and the
MEMS mirror with respect to the eye. Pupil tracker and misalignment compensation
control performance are illustrated through simulated scenarios. The project
also involves the development of a hardware prototype that is used to test algorithms
and related software.
|
9 |
Modélisations multiphysiques, réalisation et expérimentations d'un haut-parleur digital matriciel piézoélectrique MEMS / Multiphysics modeling, implementation and experimentation of a piezoelectrically actuated MEMS digital loudspeaker arrayDejaeger, Rémy 04 June 2014 (has links)
Le Haut-Parleur Digital Matriciel (HPDM) est un moyen de transduction électroacoustique qui reçoit comme entrée un signal numérique et qui effectue la conversion vers l'analogique directement dans l'air. Il est constitué de plusieurs éléments rayonnants disposés au sein d'une matrice. Ces éléments seront désignés par le terme «speaklet» lorsqu'ils sont de tailles réduites. Le rayonnement acoustique du HPDM est en effet très sensible à la taille de la matrice, ce qui le rend tout particulièrement adapté à la technologie MEMS. Cette thèse porte sur l'étude de HPDM MEMS piézoélectriques. Après une introduction qui débute par certaines généralités jusqu'à se focaliser sur le sujet, la thèse aborde les modélisations multiphysiques des HPDM étudiés, le dimensionnement des speaklets puis les tests expérimentaux. Des modèles analytiques ainsi que des simulations numériques et par éléments finis sont mis en place et permettent de prédire le comportement mécanique des speaklets présentés, les pressions rayonnées par les HPDM et les puissances électriques consommées. Les speaklets sont ensuite dimensionnés à partir de l'empilement technologique afin de maximiser le niveau de pression qu'ils génèrent. Des tests expérimentaux permettent alors de valider la majorité des modèles ou au contraire de revenir sur certains d'entre eux pour les optimiser ou montrer leurs limitations. Les résultats ont en effet montré l'importance de la prise en compte des contraintes résiduelles, qui provoquent une déformée initiale des speaklets et modifient leurs fréquences propres, rendant alors l'utilisation de grands rayons inefficaces. En accord avec les modèles, les speaklets possèdent un comportement dynamique linéaire, ce qui permet de les caractériser à l'aide de fonctions de transfert. La théorie et les enregistrements sonores montrent alors qu'un HPDM composé de tels speaklets permet dans le meilleur des cas de produire une pression identique à celle générée par la même matrice pilotée en analogique. Dans notre cas, des taux de distorsions supérieurs ont été obtenus lors des reconstructions digitales, à cause des réponses non uniformes des speaklets, dues à des résistances d'accès différentes. Le HPDM présenté possède cependant d'autres avantages, le plus important étant la très faible consommation électrique qu'il est théoriquement possible d'atteindre en utilisant les méthodes de charges et de décharges adiabatiques. Le HPDM piézoélectrique MEMS apparait donc comme étant une technologie prometteuse. L'optimisation de notre premier prototype à l'aide des outils développés doit en effet conduire à un HPDM capable de générer une pression équivalente à celle obtenue en mode analogique, mais avec un rendement électroacoustique beaucoup plus important. Les futurs travaux devront ensuite se concentrer sur la conception de speaklets non-linéaires et sur la forme du pulse de pression qu'ils génèrent, afin de gagner en niveau sonore. / The Digital Loudspeaker Array (DLA) is an electroacoustic transducer which receives as input a digital signal and performs the analog conversion directly into the air. It consists of a plurality of radiating elements arranged in a matrix. These elements will be designated by the term “speaklet” when they are reduced in size. The acoustic radiation of a DLA is indeed very sensitive to the size of the matrix due to differences in path length, which makes it especially suitable for MEMS technology. This thesis is on the study of a piezoelectric MEMS DLA. After an introduction that is increasingly focused on the subject, the thesis addresses the multiphysics modeling of the DLA, dimensioning of the speaklets and experimental tests. Analytical formulas, numerical simulations and finite element models are developed and used to predict the mechanical behavior of the presented speaklets, the pressure radiated by the DLA and the electrical power consumption. The speaklet are then dimensioned from the technological stack (set in advance) in order to maximize the pressure level. Experimental tests involving the use of an anechoic chamber, an optical interferometer, a vibrometer and an impedancemeter validate most of the models. Otherwise, these tests are usefull for improving some of them or for showing their limitations. The results have shown the importance of the residual stresses, which cause an initial deformation of the speaklets and modify their resonance frequencies, thus rendering ineffective the use of large radii. In accordance with the models, the static deflection of the speaklets is nonlinear but their dynamic behavior is linear. This enables characterizations using transfer functions. Theory and sound recordings show that a DLA made of such speaklets can produce in the best case the same pressure to that generated by the same matrix driven in an analog way. In our case, more distortions were obtained in digital reconstructions because of non-uniform responses of the speaklets, due to different access resistances. However, the presented DLA has other advantages, the most important being the very low power consumption it is theoretically possible to achieve using the adiabatic charge principle. The piezoelectric MEMS DLA thus appears as a promising technology. The optimization of our first prototype using the developed tools should indeed lead to a DLA able to generate an equivalent presure to that obtained with analog control, but with a far greater electroacoustic efficiency. Future work should then focus on the design of nonlinear speaklets and on the shaping of the pulse of pressure they generate, in order to increase the total pressure level.
|
10 |
Polyuréthanes électrostrictifs et nanocomposites : caractérisation et analyse des mécanismes de couplages électromécaniques / Electrostrictive polyurethanes and nanocomposites : characterization and analyse of the mechanisms of electromechanical couplingsWongtimnoi, Komkrisd 19 December 2011 (has links)
Depuis quelques années on s'intéresse aux actionneurs base polymères, souvent appelés polymères électroactifs électroniques (EAPS) pour intégrer dans des microsystèmes électromécaniques (MEMS). Trois mécanismes sont à l'origine du couplage électromécanique : (i) la piézoélectricité qui apparait dans certaines phases cristallines, (ii) la force "de Maxwell" lorsqu'un champ électrique aux bornes du condensateur constitué d'un polymère souples placé entre deux électrodes, et (iii) l'électrostriction, phénomène intrinsèque aux matériaux polaires, mal connu. Les deux derniers se traduisent par une dépendance quadratique de la déformation macroscopique avec le champ électrique appliqué. Parmi les EAPs électrostrictifs, on cite souvent certains polyuréthanes (PU) qui a conduit à ce choix pour ce travail de thèse. Une première partie a consisté à analyser en détail l'électrostriction de 3 PUs, copolymères à blocs de deux types d'unités de répétition, les unes conduisant à des segments rigides très polaires, les autres à des segments souples peu polaires. La séparation de phase qui apparait lors de la mise en œuvre de ces PUs (contenant des fractions différentes de segments souples et rigides) semble propice à l'apparition de leur électrostriction. C'est ce qu'indique une modélisation récemment proposée qui prédit un facteur de près de 1000 entre forces de Maxwell (ici négligeables) et électrostriction. Le comportement des matériaux résultent clairement de la compétition entre contraintes d'origine électrostatique (dipôles des phases polaires dans un gradient de champ électrique) et contraintes mécaniques liées à la rigidité des phases. L’influence systématique de l'épaisseur des films sur leur activité électromagnétique a été rendue compte: les films minces présentent une plus faible déformation à champ électrique donné que les films plus épais. Les films obtenus par évaporation du solvant utilisé pour dissoudre les PU présentent probablement un gradient de microstructure : en surface, l'évaporation rapide limite la séparation de phase, alors qu'elle est plus avancée à cœur. C’est cohérent avec la modélisation reposant sur la présence de gradient de constante diélectrique au sein des films. Dans une dernière partie, on a cherché à augmenter encore l'électrostriction de ces matériaux en dispersant des particules conductrices à conduction électronique, de taille nanométrique (noir de carbone et nanotubes de carbone). On observe trois effets, l'un correspondant à l'augmentation de la constante diélectrique apparente (celle diverge au seuil de percolation), et un deuxième effet à une augmentation des forces d'attraction locales. En revanche, le troisième effet qui contrecarre les forces d'origine électrostatique puisqu'il résulte de l'augmentation de la rigidité dû à la présence des particules rigides. Là encore, la compétition entre contraintes électrostatique et mécanique conduit à un optimum en termes de fraction volumique de particules renforçantes. / Piezoelectric ceramics are commonly used for actuation applications. However, they suffer from several drawbacks particularly such low electric field-induced strains and difficult implementation inside microelectromechanical systems (MEMS). Recently, electroactive polymers (EAPs) have attracted considerable interest, especially following the publication of elevated electric field-induced strain values. The results have rendered EAPs very attractive for replacing the lead-based ceramics. Three mechanisms are responsible for the electromechanical coupling in electronic EAPs: (i) The piezoelectricity that appears in some crystalline phases, (ii) The “Maxwell” forces when applying an electric field through a capacitor which consists of a flexible polymer film placed between two electrodes, and (iii) The electrostriction, an intrinsic phenomenon related to polar materials, which is still poorly understood. The last two mechanisms result in a quadratic dependence of the deformation with the applied electric field. Among the electrostrictive EAPs, some polyurethanes (PU) have been often cited, and have therefore guided the choice of the materials for this work. The first part was to analyze the electrostrictive behavior of three PUs, made of two partially miscible types of repeating units: the high polar hard segments and the low polar soft segments. The phase separation occurred during the elaboration process of these PU films seems favorable to the emergence of electrostrictive behavior. A model predicted recently an almost 1000 factor between the electrostriction and the Maxwell stress (here negligible). This is clearly related to the competition between the electrostatic strains (polar phases dipoles in a field gradient) and the mechanical stresses. The thickness of films was found to have a strong influence on electromechanical activity: thin films present a lower strain for a given electric field compared to thick films. Depending on the solvent evaporation during the film elaboration, the films exhibit a thickness gradient in the microstructure: Fast evaporation on the surface inhibits the phase separation, whereas it is more favored in the core. This is consistent with the modeling based on the gradient of dielectric constant in PU. In the last part, we aimed to further increase the electrostriction of PU by filling with nanoscale conductive particles (carbon black or carbon nanotubes). This normally results three effects, one corresponding to the increase of the dielectric constant in the vicinity of the percolation threshold, a second effect relates to an increase in local attractive forces which behave as internal constraints. In contrast, the third effect counteracts the electrostatic forces since it results from the increased stiffness due to the hard particles. Again, the competition between electrostatic and mechanical stress leads to an optimum induced-deformation associated to a fraction of reinforcing particles.
|
Page generated in 0.1149 seconds