• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 141
  • 4
  • 1
  • Tagged with
  • 147
  • 128
  • 29
  • 28
  • 26
  • 22
  • 20
  • 20
  • 19
  • 18
  • 17
  • 17
  • 17
  • 16
  • 16
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Efeito do tipo de fonte de luz sobre propriedades físicas de cimentos resinosos experimentais contendo diferentes sistemas fotoiniciadores / Effect of light curing units on the physical properties of experimental resin cements containing different photoinitiators systems

Leonardo Freitas da Silveira 25 March 2013 (has links)
Cimentos resinosos experimentais contendo diferentes sistemas fotoiniciadores apresentaram propriedades físicas semelhantes ou superiores a cimentos resinosos convencionais sob efeito de diferentes tipos de fonte de luz. Objetivo: Analisar o espectro de diferentes fontes de luz e sistemas fotoiniciadores e sua influência nas propriedades físicas de cimentos resinosos quando ativados, através de um anteparo cerâmico, por fontes de luz halógena e LED. Metodologia: Cimentos resinosos experimentais contendo uma mistura de BisGMA, TEGDMA (50wt%) e partículas de carga silanizadas (65wt%), foram preparados com o uso dos fotoiniciadores Canforoquinona (CQ), Fenil Propanodiona (PPD) e Óxido bis-alquil fosfínico (BAPO) de forma isolada e combinados. Os co-iniciadores utilizados foram Difenil Iodônio (DFIHFP) e a amina terciária DMAEMA. As fontes de luz utilizadas foram: lâmpada halógena (XL 2500) e duas fontes de diodo emissor de luz - LED (FreeLigth 2 e Bluephase). Um anteparo cerâmico (IPS e.max Press) apresentando 13,0mm x 1,0mm de espessura foi utilizado durante os testes. Amostras com 7,0mm x 2,0mm x 1,0mm foram confeccionadas (n=360). A avaliação do Grau de Conversão (GC) dos cimentos experimentais foi realizada por Espectroscopia de Infravermelho Transformada de Fourier (FTIR), sendo em seguida submetidas ao teste de resistência à mini-flexão, módulo flexural e microdureza Knoop. Os resultados obtidos em todos os testes foram submetidos à análise de variância dois fatores - ANOVA e teste de Tukey (5%). Resultados: A associação do DFIHFP aos fotoiniciadores aumentou as propriedades avaliadas de todos os cimentos experimentais independente da fonte de luz (FL) utilizada. O fotoiniciador BAPO apresentou resultados superiores ou iguais estatisticamente em comparação ao grupo controle (CQ/amina), independente da FL utilizada. Conclusão: A utilização de sistemas iniciadores e co-iniciadores alternativos possibilita a obtenção de propriedades superiores ou iguais ao sistema convencional, tornando-se um sistema promissor para atuar de forma isolada ou associada. / Resin cements containing different experimental photoinitiators systems present physical properties similar to or better than conventional resin cements under the effect of different types of light source. Objective: To analyze the spectrum of different light sources and systems photoinitiators and their influence on physical properties of resin cements when activated through a bulkhead ceramic, halogen light sources and LED. Methodology: experimental resin cements containing a mixture of BisGMA, TEGDMA (50wt%) and silanized filler particles (65wt%) were prepared with the use of photoinitiators camphorquinone (CQ), phenyl oxide bis-propanedione (PPD) and alkyl phosphinic (BAPO) separately and combined. The primers used were co-diphenyl iodonium (DFIHFP) tertiary amine and DMAEMA. The light sources used were: halogen lamp (XL 2500) and two sources of light emitting diode - LED (FreeLigth bluephase and 2). A ceramic shield (IPS e.max Press) having 13.0mm x 1.0mm thick was used for testing. Samples with 7.0mm x 2.0mm x 1.0mm were fabricated (n=360). The evaluation of the degree of conversion (GC) of experimental cements was performed by Infrared Spectroscopy Fourier Transform, and then to test for resistance to mini-bending, flexural modulus and microhardness. The results in all tests were subjected to two-factor analysis of variance - ANOVA and Tukey test (5%). Results: The combination of photoinitiators DFIHFP to improve board properties of all the experimental cements independent light source (LCU) used. The photoinitiator BAPO showed statistically equal or better results compared to the control group (CQ / amine), regardless of LCU used. Conclusion: The use of systems co-initiators and initiators to obtain alternative provides equal or better properties to the conventional system, making it a promising system to act in isolation or in combination.
132

[en] ANALYSIS OF THE PARAMETERS OF FRICTION WELDING (FSW) THROUGH THE MEASURES OF TORQUE AND FORCES INVOLVED IN THE PROCESS / [pt] ANÁLISE DOS PARÂMETROS DE SOLDAGEM POR FRICÇÃO (FSW) ATRAVÉS DAS MEDIDAS DE TORQUE E FORÇAS ENVOLVIDAS NO PROCESSO

MARCOS VINICIUS DE OLIVEIRA MARTINS 28 August 2020 (has links)
[pt] A união de materiais por soldagem é um dos processos mais utilizados na fabricação de estruturas. A soldagem traz maior confiabilidade, segurança ao projeto e resistência mecânica das uniões. Atualmente, diversas indústrias, tais como aeronáutica e automotiva, têm procurando utilizar materiais de baixa densidade e alta resistência mecânica, como as ligas de magnésio e de alumínio. Porém, estas ligas dificultam o processo de união através da soldagem convencional, que tem no seu principal fundamento a fusão do material, por possuírem baixa soldabilidade. Nas ligas de Mg e de Al há a formação uma camada de óxido que precisa ser removida durante o processo de soldagem, além de apresentarem grande susceptibilidade a geração de defeitos, tais como trincas e poros durante o processo de resfriamento da solda. A soldagem por fricção ou por mistura mecânica (FSW) foi desenvolvida como uma alternativa às técnicas de soldagem e uso mais comum existente na indústria, pois esta técnica elimina a fusão do material reduzindo, assim, os defeitos que surgiriam com a soldagem convencional. Por ser uma solda de estado sólido, tem a possibilidade de unir materiais dissimilares, polímeros, compósitos, ligas ferrosas e não ferrosas. O presente trabalho buscou avaliar parâmetros de soldagem variando a velocidade de soldagem (ν) e velocidade de rotação da ferramenta (ômega) utilizando uma ferramenta com rosca. Foram analisados o torque e as forças presentes no processo. Os resultados foram comparados com os resultados obtidos com uma ferramenta de soldagem sem rosca. A qualidade da solda foi correlacionada com os parâmetros de soldagem utilizados por meio de ensaios de dureza e tomografia. Foi concluído que a ferramenta com rosca gera defeito de túnel e demanda maior energia do processo em relação ao torque e à força axial. O comportamento das forças envolvidas no processo foi o mesmo para ambas as geometrias de ferramenta. A microdureza ao longo do eixo neutro mostrou a mudança entre a zona de mistura, zona termicamente afetada e o metal de base. / [en] The joining of materials by welding is the process most used in the fabrication of structures. Welding brings greater reliability, safety to the design and mechanical strength of the joints. Today, many industries, such as aeronautics and automotive, are looking to use low density and high mechanical strength materials such as magnesium and aluminum alloys. However, these alloys hinder the bonding process through conventional welding, which has in its main foundation the melting of the material, because they have low weldability. In Mg and Al alloys there is a layer of oxide that needs to be removed during the welding process, besides being very susceptible to the generation of defects, such as cracks and pores during the process of cooling the weld. Friction stir welding (FSW) was developed as an alternative to most commonly used in industry welding techniques, as this technique eliminates melting of the material thus reducing defects that would arise with conventional welding. To being a solid state weld, it has the possibility of joining dissimilar materials, polymers, composites, ferrous and non-ferrous alloys. The present work seeked to evaluate welding parameters by varying the welding speed (ν) and tool rotation (omega) using a threaded tool. The torque and forces were analyzed and the results will be compared with the results obtained with a threadless welding tool. The quality of the weld will be correlated with the welding parameters used by means of hardness test and tomography. It was concluded that the threaded tool generates tunnel defect and demands higher process energy. The behavior of the forces involved in the process was the same for both tool geometries. The microhardness along the neutral axis showed the clear the change between the mixing zone, thermally affected zone and the base metal.
133

Espectroscopia e difração de raios X aplicadas ao estudo de ferro e aço nitretados por plasma / Spectroscopy and X-ray diffraction applied to the state of iron and steel by plasma nitriding

Miola, Eduardo José 25 August 2000 (has links)
Este trabalho apresenta um estudo sobre a formação e evolução da camada de nitretos sobre substrato de ferro com pureza de 99,83% e do aço AISI H12, nitretados por plasma. As camadas foram obtidas com a variação sistemática das condições de nitretação, como temperatura, tempo e frequência do plasma. A atmosfera de trabalho empregada foi a de uma mistura gasosa de 20% N2 + 80% H2, mantida à pressão constante de 6 mbar, sob fluxo. Uma investigação detalhada da camada nitretada das amostras de ferro foi feita através de desgaste mecânico em passos sucessivos e após cada desgaste, as novas camadas foram analisadas por espectroscopia Môssbauer de elétrons de conversão (CEMS) auxiliadas por outras técnicas, como difração de raios X, microdureza e microscopia ótica e eletrônica. As análises superficiais demonstraram que a camada nitretada é formada por uma mistura de nitretos γ-Fe4N, ε-Fe3N e-ε-Fe3,2N, que variam suas proporções com as condições de nitretação. Abaixo desta camada outros nitretos são formados como e ε-FeXN (2≤X≤3,2) e α-Fe16N2. No aço H12, foi estudada a influência da nitretação por plasma em correntes contínua e pulsada. As amostras foram caracterizadas quanto ao perfil de microdureza, perfil de concentração de nitrogênio, difração de raios X e espectroscopia Môssbauer de elétrons de conversão (CEMS) e de raios X de conversão (CXMS). A camada composta próxima à superfície, como vista por CEMS, consiste de uma mistura de γ-Fe4N e ε-FeX(N, C) enquanto a camada próxima à zona de difusão, investigada por CXMS, consiste de uma mistura de fases γ-Fe4N, ε-FeX(N, C) Fex(N, C), α-Fe16N2 e γ-austenita. O crescimento da camada nitretada quando difundida utilizando corrente contínua segue uma lei parabólica, o que não ocorre com o processo com corrente alternada. Este efeito deve ser devido à taxa de \"sputerring\" do catodo e da difusão auxiliada por radiação, que são mais acentuadas no caso de corrente alternada, para tempos de nitretação t ‹ 2h. A situação é revertida para t › 3h. / This work investigates the formation and evolution of nitride layers on a 99.83% pure iron and a AISI H-12 steel substrates by using plasma nitriding processoThe layers were obtained by systematic variation of the nitriding conditions, such as temperature, time and plasma frequency. The employed atmosphere consisted of a gaseous mixture of H2-20% N2, at a constant pressure of 6.0 mbar in f1ux.A detailed investigation of the nitrided layer on iron samples was performed through surface mechanical wear in successive steps. After each step the layer was analysed by Conversion Electron Mõssbauer spectroscopy (CEMS), as well as by other techniques, as X-ray diffraction, microhardness and optical and electronic metallography. The surface analysis of iron samples showed that the nitrided layers are formed bya mixture of γ-Fe4N, ε-Fe3N e-ε-Fe3,2N nitrides, whose proportions have varied with the nitriding conditions. Below this layer, different nitrides are formed, ε-FeXN (2≤X≤3,2) e α-Fe16N2. For H-12 steel substrates it was also studied the influence of direct and pulsed current on the layer. The samples were characterized related to the microhardness profile, nitrogen concentration profile, Xray diffraction and Conversion Electron and X-ray Mõssbauer spectroscopy (CEMS) and (CXMS). The near-surface compound layer, as probed by CEMS, consisted of a mixture of γ-Fe4N e ε-FeX(N, C) phases. The near-diffusion zone compound layer, as probed by CXMS presented a mixture of γ-Fe4N , e ε-FeX(N, C) Fex(N, C), α-Fe16N2e &#947 and- e &#947-austenite phases. For the plasma process, the growth of the nitride layers in direct current follows the parabolic law, what does not occur when process with pulsed current is used. This effect is probably due to cathode rate sputtering and radiation-enhanced diffusion, the latter being more accentuated in the case of pulsed current, for nitriding times t &#8249 2h. The situation is reversed for t &#8250 3h.
134

ESTUDO DA CAMADA TRATADA GERADA POR REFUSÃO SUPERFICIAL A LASER DA LIGA AL-1,5%FE

Bertoni, Jean Cleber 30 January 2015 (has links)
Made available in DSpace on 2017-07-21T20:43:46Z (GMT). No. of bitstreams: 1 Jean Cleber Bertoni.pdf: 7862049 bytes, checksum: 4c77f7ebc3fc211aac8ad8a7de58ccad (MD5) Previous issue date: 2015-01-30 / There are currently extensive research on aluminum alloys, mainly due to its wide application in the automotive and aerospace industries, due to the following characteristics, among them, low density, high thermal conductivity and high corrosion resistance at room temperature. Al-Fe alloys have a high degree of microstructural change due to changes in their properties when appropriate techniques are applied. The Al-Fe alloy was studied in the composition of 1.5% Fe by weight, which was subjected to the treatment laser surface remelting in order to enhance its surface characteristics. The characterization of these alloys in order to determine the variation of the chemical composition at different depths was performed by Grazzing incidence x-ray diffraction (GIXRD). In this technique, the angle of incidence of the X-ray beam was fixed and the detector moved in 2θ, it is possible to obtain the XRD patterns at different depths by varying the angle of incidence. In this work, the characterizations the micro and nano structural sample of alloy Al-1.5wt.%Fe treated by laser surface remelting (LSR) were performed, on the treated surface, as well as the transverse section, this study was performed at treated samples surface and at the isolated weld fillet on samples, where were applied laser beam speeds of 20, 40 and 60 mm / s. In this study we used different characterization techniques, such as, optical microscopy, scanning electron microscopy, energy dispersive spectroscopy, together with atomic force microscopy, and the Vickers hardness. Also in this work the technique of GIXRD was used to obtain depth profiles of near the surface chemical composition of the alloy. The analysis was performed in the micrometer range varying the angle of incidence between 0.5° to 6° in steps of 0.5° and analysis with incident angles 3° and 6° in steps of 0.02° for each 10 sec. As a result by examining the microstructure was characterized melted zone, the heat affected zone and the substrate, a particular features were found for each velocity of the laser beam, generally the treated area showed a more homogenous microstructure consisting of grains smaller feature, with low roughness and high hardness. The heat affected zone was more notorious the morphology of grains elongated feature in the treated and untreated interface for low laser beam scanning velocities. By means of the technique of X-ray diffraction various metastable phases were found, such as aluminum oxide, nitrides, etc., with different intensities of peaks as a consequence of the variation of angle of incidence. / Atualmente há uma ampla investigação sobre ligas de alumínio, principalmente devido a sua larga aplicação na indústria automotiva e aeroespacial, devido as seguintes características, entre elas, a baixa densidade, alta condutividade térmica e elevada resistência à corrosão a temperatura ambiente. Ligas de Al-Fe possuem um alto grau de modificação microestrutural, devido a mudanças em suas propriedades quando técnicas adequadas forem aplicadas. A liga Al-Fe foi estudada na composição de 1,5% de Fe em peso, a qual foi submetida ao tratamento de refusão superficial a laser de modo a aprimorar suas características superficiais. A caracterização dessas ligas com a finalidade de determinar à variação de composição química em diferentes profundidades foi realizado mediante a difração de raios X com ângulo de incidência rasante (DRXIR). Nesta técnica, o ângulo de incidência do feixe de raios X foi fixado e o detector moveu-se em 2θ, sendo possível obter os difratogramas em diferentes profundidades com a variação do ângulo de incidência. Neste trabalho, as caracterizações a nível micro e nano estrutural das amostras da liga Al-1,5%Fe tratadas por refusão superficial a laser (RSL) foram realizadas, tanto na superfície tratada e bem como na parte transversal, este estudo foi realizado nas amostras tratadas em toda a superfície, quanto nas amostras com trilhas isoladas que foram aplicadas as velocidades de feixe laser de 20, 40 e 60 mm/s. Para isso foram utilizados diferentes técnicas de caracterização, tais como, microscópio ótico, microscópio eletrônico de varredura, espectroscopia por energia dispersiva, acompanhada da microscopia de força atômica, bem como da microdureza Vickers. Também neste trabalho a técnica de DRXIR foi utilizada para obtenção de perfis de profundidade da composição química próxima à superfície da liga. A análise foi realizada em escala micrométrica por meio da variação do ângulo de incidência entre 0,5° a 6° com passos de 0,5°, bem como as análises com ângulos incidentes de 3º e 6º com passos de 0,02º a cada 10 s. Como resultado mediante o estudo microestrutural foram caracterizados a zona fundida, a zona afetada termicamente e o substrato, sendo encontradas características particulares para cada velocidade do feixe de laser, de modo geral a zona tratada mostrou ter uma característica microestrutural mais homogênea formada por grãos menores, com baixa rugosidade e de alta dureza. A zona afetada termicamente mostrou ser mais notória a morfologia de grãos com característica alongada na interface tratada e não tratada para baixas velocidades de varredura do feixe laser. Por meio da técnica de difração de raios X diferentes fases metaestáveis foram encontradas, tais como, óxido de alumínio, nitretos, etc, com diferentes intensidades de picos como consequência da variação do ângulo de incidência.
135

EFEITO DA DENSIDADE DE ENERGIA DE FOTOATIVADORES DE ALTA POTÊNCIA NAS PROPRIEDADES FÍSICO-MECÂNICAS DE UMA RESINA ORTODÔNTICA

Arana, Andrés Fernando Montenegro 16 October 2017 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-03-01T13:44:47Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Andrés Fernando Montenegro.pdf: 11976346 bytes, checksum: fa909dec838336e8c5a4ed73180bb65b (MD5) / Made available in DSpace on 2018-03-01T13:44:47Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Andrés Fernando Montenegro.pdf: 11976346 bytes, checksum: fa909dec838336e8c5a4ed73180bb65b (MD5) Previous issue date: 2017-10-16 / O objetivo deste estudo foi verificar o efeito da densidade de energia e o tempo de exposição de fotopolimerizadores LED de terceira geração em uma resina ortodôntica disponível comercialmente nos valores de microdureza, cisalhamento, índice de remanescente de resina e grau de conversão. Para tanto, foram realizados 3 experimentos: Experimento 1, o objetivo foi avaliar o grau de conversão (DC) e microdureza vickers (MHV) da resina ortodôntica utilizando dois LEDs de terceira geração, assim como, protocolos de fotoativação diferentes. Foram necessários 80 brackets cerâmicos e 80 brackets metálicos, sendo divididos em 16 grupos experimentais (n=10) tendo os seguintes grupos para cada LED: um grupo controle, diminuição da metade do tempo de exposição do grupo controle, um quarto do tempo do grupo controle, função turbo ou plasma para os LEDs Bluephase e Valo, respetivamente. Imediatamente após a polimerização, foram realizados os ensaios de DC e MHV. O experimento 2, objetivou verificar a influência de diferentes densidades de energia emitidas por dois fotoativadores LED de alta potência nas propriedades físicas e mecânicas de uma resina ortodôntica em brackets metálicos. Foram necessários 80 pré-molares superiores, sendo usadas as superfícies vestibulares dos dentes para a colagem dos 80 brackets metálicos. Os dentes foram divididos aleatoriamente em 8 grupos experimentais (n=10), sendo: um grupo controle, redução da metade do tempo de exposição do grupo controle, um quarto do tempo do grupo controle, função plasma ou turbo para cada LED estudado, sendo Valo e Bluephase. Após 24 horas da polimerização, foram realizados os testes de cisalhamento (SBS), índice remanescente de resina (ARI) e MHV. O objetivo do experimento 3 foi verificar a influência de diferentes densidades de energia depositadas por dois fotoativadores LED diferentes de alta potência nas propriedades físicas e mecânicas de uma resina ortodôntica em brackets cerâmicos. Foram necessários 80 dentes pré-molares superiores hígidos, sendo utilizadas as superfícies linguais ou palatinas dos dentes para colagem dos 80 brackets cerâmicos. Os dentes foram divididos aleatoriamente em 8 grupos experimentais (n=10), foram formados grupos iguais para cada LED Valo e Bluephase: um grupo controle, diminuição da metade do tempo de exposição do grupo controle, um quarto do tempo do grupo controle, função turbo do LED Bluephase ou plasma do LED Valo. Após 24 horas da polimerização, foram realizados os testes de SBS, ARI e MHV. Os resultados de cada experimento foram analisados através de testes estatísticos específicos, para determinar se houve ou não diferença estatisticamente significativa. Para o experimento 1 foram realizados ANOVA de duas vias e teste de Tukey (α=0,05), para o experimento 2 e 3 foram realizados Anova de duas vias com testes de Tukey (α=0,05). O experimento 1 mostrou que os grupos dos brackets cerâmicos tem baixa variação, porém pequenas mudanças no aumento dos valores da energia aplicada em Joules totais aumentam os valores de DC e MHV, nos brackets metálicos pelo fato de impedir a passagem da luz o DC e HVK diminuem significativamente, permanecendo dentro dos parâmetros considerados normais. O experimento 2 mostrou que ambos LED utilizados foram efetivos tanto na função standard como na turbo ou plasma, sendo que as funções turbo ou plasma ofereceram resultados similares aos do controle, efetivando mesmo com a redução do tempo para a polimerização dos brackets metálicos. No experimento 3 não houve diferença estatisticamente significativa nos grupos analisados. Os LEDs estudados proporcionaram valores suficientes de Joules em alguns grupos experimentais sendo este suficiente para atingir bons valores no DC, SBS e MHV. O uso de LEDs com uma potência adequada, sendo o mínimo de 1200 mW/cm2, ou o uso de uma potência elevada de entre 2400 a 3200 mW/cm2 e um curto período de tempo de exposição entre 3 a 6 segundos, são efetivos para a colagem de acessórios ortodônticos. / The objective of this study was to verify the effect of energy density and the time of exposure of third generation LED light curing agents on a commercially available orthodontic resin in the values of microhardness, shear, resin remaining index and degree of conversion. Three experiments were carried out: Experiment 1, the objective was to evaluate the degree of conversion (DC) and microhardness vickers (MHV) of the orthodontic resin using two third generation LEDs, as well as different photoactivation protocols. 80 ceramic brackets and 80 metallic brackets were required and divided into 16 experimental groups (n=10), with the following groups for each LED: control group, one half, one quarter of the control group time, turbo or plasma function for the Bluephase and Valo LEDs, respectively. Immediately after the polymerization, the DC and MHV assays of the specimens were performed. The experiment 2, aimed to verify the influence of different energy densities emitted by two high power LED photoactivators on the physical and mechanical properties of an orthodontic resin in metallic brackets. For this experiment, 80 carious cavity-free, superior human premolar teeth were used, and the buccal surfaces of the teeth were used for the bonding of the 80 metal brackets. The teeth were randomly divided into 8 experimental groups (n=10), with the following groups being a control group, half the time of exposure of the control group, one quarter of the time in the control group, plasma or turbo function for each LED studied, being Valo and Bluephase. After polymerization, the teeth and specimens were stored 24h at 37°C to perform the shear tests (SBS), resin remaining index (ARI) and MHV. The objective of experiment 3 was to verify the influence of different energy densities deposited by two different LED light-curing on the physical and mechanical properties of an orthodontic resin in ceramic brackets. For this experiment, it was necessary to have 80 carious free upper premolar human teeth, using the lingual or palatine surfaces of the teeth for bonding the 80 ceramic brackets. The teeth were randomly divided into 8 experimental groups (n=10), equal groups were formed for each Valo and Bluephase LEDs: one control group, one half-time control group exposure time, one-fourth time control group, function LED Bluephase turbo or LED Valo Plasma. After polymerization, the teeth and specimens were stored 24 hours at 37°C to perform the SBS, ARI and MHV tests. The results of each experiment were analyzed by specific statistical tests to determine whether or not there was a statistically significant difference. For experiment 1, 2 and two-way ANOVA and Tukey's test (α=0.05) were performed. Experiment 1 showed that the groups of ceramic brackets have low variation, but small changes in the increase of the values of the applied energy in total Joules increase the values of DC and MHV in the metallic brackets because it prevents the passage of light the DC and HVK decrease significantly, remaining within the parameters considered normal. Experiment 2 showed that both LEDs were effective both in the standard function and in the turbo or plasma, and the turbo or plasma functions gave similar results to the control, even effecting with the reduction of the time for the polymerization of the metal brackets. In the experiment 3 there was no statistically significant difference in the analyzed groups. The studied LEDs provided sufficient values of Joules in some experimental groups being sufficient to reach good values in DC, SBS and HVK. The use of LEDs with adequate power, being at least 1000 mW/cm2, or the use of a high power of between 2400 and 3200 mW/cm2 and a short period of exposure of between 3 to 6 seconds, are sufficient for the bonding of orthodontic accessories.
136

Efeito do uso sistêmico de alendronato sódico no tecido ósseo e nas estruturas dentárias mineralizadas: estudo químico, mecânico e morfológico, em modelo murino / Effect of the systemic use of sodium alendronate on bone tissue and mineralized dental structures: A chemical, mechanical and morphological study in a murine model.

Marília Pacifico Lucisano 10 December 2010 (has links)
Os bisfosfonatos representam uma classe de drogas que agem sobre o metabolismo ósseo e são amplamente utilizadas na prevenção e tratamento de estados osteopênicos e osteoporóticos. Os objetivos do presente estudo foram avaliar, in vivo, o efeito do uso sistêmico de alendronato sódico: na densidade mineral óssea de ratos, por meio da densitometria óptica radiográfica e da técnica de absortometria radiológica de dupla energia (DXA); e nas estruturas dentárias mineralizadas de incisivos murinos, por meio da espectrometria na região do infravermelho, espectroscopia de fluorescência, microdureza transversal, microscopia eletrônica de varredura e microscopia de luz polarizada. Foram utilizados 45 ratos Wistar, com 36-42 dias de idade, pesando em média 200-230g, os quais foram divididos em dois grupos: experimental (n= 25) e controle (n= 20). No grupo experimental foram administradas duas doses semanais de 1mg/Kg de alendronato de sódio quimicamente puro diluído em água destilada, via gavagem, enquanto que os animais do grupo controle receberam apenas água destilada. Decorrido o período de 60 dias, os animais foram mortos por sobredose anestésica e, em seguida, foram extraídos os incisivos superiores e removidas as tíbias. As tíbias foram submetidas à avaliação da densidade mineral óssea por meio de análise radiográfica e da técnica de absortometria radiológica de dupla energia (DXA). Os incisivos superiores foram submetidos às seguintes avaliações: análise química por espectrometria na região do infravermelho e espectroscopia de fluorescência, microdureza transversal do esmalte e da dentina; microscopia eletrônica de varredura e microscopia de luz polarizada. Os resultados numéricos obtidos foram submetidos à análise estatística por meio do teste não-paramétrico de Kruskal-Wallis, utilizando o software SAS (Statistical Analysis System) for Windows versão 9.1.3. O nível de significância adotado foi de 5%. O grupo experimental apresentou valores de densidade mineral óssea superiores (p<0,05) em relação ao grupo controle, pelos métodos da densitometria óptica radiográfica e DXA. A análise química pelos métodos de espectrometria na região do infravermelho e espectroscopia de fluorescência permitiu detectar a presença do alendronato na estrutura dentária mineralizada do grupo experimental e que a porcentagem dessa incorporação foi de 0,0018% por elemento dental. Os resultados da microdureza transversal do esmalte e da dentina não revelaram diferença estatisticamente significante entre os grupos experimental e controle (p>0,05). Não foram observadas diferenças morfológicas significativas entre as amostras de ambos os grupos por meio da análise por microscopia eletrônica de varredura e microscopia de luz polarizada. Com base nos resultados obtidos, conclui-se que o tratamento com alendronato sódico provocou aumento na densidade mineral óssea da metáfise proximal da tíbia e que o alendronato incorporou-se nas estruturas dentárias mineralizadas, porém sem provocar efeitos significativos na microdureza e na morfologia do esmalte e da dentina de incisivos de ratos. / Bisphosphonates represent a class of drugs that act on bone metabolism and are widely used in the prevention and treatment of osteopenic and osteoporotic states. The objectives of this study were to evaluate, in vivo, the effect of the systemic use of sodium alendronate on: the mineral bone density of rats, by radiographic optical densitometry and dual-energy x-ray absorptiometry (DXA); the mineralized dental structures of murine incisors, by analysis of infrared (IR) spectrometry, fluorescence spectroscopy, cross-sectional microhardness (CSMH), scanning electron microscopy (SEM) and polarized light microscopy (PLM). Forty-five Wistar rats aged 36-42 days and weighing 200-230 g were assigned to two groups: experimental (n= 25) and control (n= 20). The experimental group received two weekly doses of 1 mg/kg of chemically pure sodium alendronate diluted in distilled water, via gavage, while the animals of the control group received only distilled water. After 60 days, the animals were killed by anesthetic overdose, and the maxillary incisors were extracted and the tibias were removed. The mineral bone density of the tibias was analyzed radiographically and by DXA. The maxillary incisors were subjected to the following evaluations: chemical analysis by IR spectrometry and fluorescence spectroscopy, enamel and dentin CSMH, SEM and PLM. The results were subjected to statistical analysis by the Kruskal-Wallis non-parametric test, using the SAS (Statistical Analysis System) software for Windows version 9.1.3. The significance level was set at 5%. The experimental group presented higher mineral bone density (p<0.05) than the control group, by radiographic optical densitometry and DXA. The chemical analysis by IR spectrometry and fluorescence spectroscopy revealed the presence of alendronate in the mineralized dental structure of the specimens of the experimental group, with a percentage of incorporation of 0.0018% per tooth. The results of enamel and dentin CSMH did not show statistically significant difference between the experimental and control groups (p>0.05). There were no significant morphological differences among the specimens of the groups by SEM and PLM. Based on the obtained results, it may be concluded that the treatment with sodium alendronate caused an increase in the mineral bone density of the proximal tibial metaphysis, and that alendronate was incorporated in the mineralized dental structures without causing significant effects in the enamel and dentin microhardness and morphology of rat incisors.
137

Efeito do uso sistêmico de alendronato sódico no tecido ósseo e nas estruturas dentárias mineralizadas: estudo químico, mecânico e morfológico, em modelo murino / Effect of the systemic use of sodium alendronate on bone tissue and mineralized dental structures: A chemical, mechanical and morphological study in a murine model.

Lucisano, Marília Pacifico 10 December 2010 (has links)
Os bisfosfonatos representam uma classe de drogas que agem sobre o metabolismo ósseo e são amplamente utilizadas na prevenção e tratamento de estados osteopênicos e osteoporóticos. Os objetivos do presente estudo foram avaliar, in vivo, o efeito do uso sistêmico de alendronato sódico: na densidade mineral óssea de ratos, por meio da densitometria óptica radiográfica e da técnica de absortometria radiológica de dupla energia (DXA); e nas estruturas dentárias mineralizadas de incisivos murinos, por meio da espectrometria na região do infravermelho, espectroscopia de fluorescência, microdureza transversal, microscopia eletrônica de varredura e microscopia de luz polarizada. Foram utilizados 45 ratos Wistar, com 36-42 dias de idade, pesando em média 200-230g, os quais foram divididos em dois grupos: experimental (n= 25) e controle (n= 20). No grupo experimental foram administradas duas doses semanais de 1mg/Kg de alendronato de sódio quimicamente puro diluído em água destilada, via gavagem, enquanto que os animais do grupo controle receberam apenas água destilada. Decorrido o período de 60 dias, os animais foram mortos por sobredose anestésica e, em seguida, foram extraídos os incisivos superiores e removidas as tíbias. As tíbias foram submetidas à avaliação da densidade mineral óssea por meio de análise radiográfica e da técnica de absortometria radiológica de dupla energia (DXA). Os incisivos superiores foram submetidos às seguintes avaliações: análise química por espectrometria na região do infravermelho e espectroscopia de fluorescência, microdureza transversal do esmalte e da dentina; microscopia eletrônica de varredura e microscopia de luz polarizada. Os resultados numéricos obtidos foram submetidos à análise estatística por meio do teste não-paramétrico de Kruskal-Wallis, utilizando o software SAS (Statistical Analysis System) for Windows versão 9.1.3. O nível de significância adotado foi de 5%. O grupo experimental apresentou valores de densidade mineral óssea superiores (p<0,05) em relação ao grupo controle, pelos métodos da densitometria óptica radiográfica e DXA. A análise química pelos métodos de espectrometria na região do infravermelho e espectroscopia de fluorescência permitiu detectar a presença do alendronato na estrutura dentária mineralizada do grupo experimental e que a porcentagem dessa incorporação foi de 0,0018% por elemento dental. Os resultados da microdureza transversal do esmalte e da dentina não revelaram diferença estatisticamente significante entre os grupos experimental e controle (p>0,05). Não foram observadas diferenças morfológicas significativas entre as amostras de ambos os grupos por meio da análise por microscopia eletrônica de varredura e microscopia de luz polarizada. Com base nos resultados obtidos, conclui-se que o tratamento com alendronato sódico provocou aumento na densidade mineral óssea da metáfise proximal da tíbia e que o alendronato incorporou-se nas estruturas dentárias mineralizadas, porém sem provocar efeitos significativos na microdureza e na morfologia do esmalte e da dentina de incisivos de ratos. / Bisphosphonates represent a class of drugs that act on bone metabolism and are widely used in the prevention and treatment of osteopenic and osteoporotic states. The objectives of this study were to evaluate, in vivo, the effect of the systemic use of sodium alendronate on: the mineral bone density of rats, by radiographic optical densitometry and dual-energy x-ray absorptiometry (DXA); the mineralized dental structures of murine incisors, by analysis of infrared (IR) spectrometry, fluorescence spectroscopy, cross-sectional microhardness (CSMH), scanning electron microscopy (SEM) and polarized light microscopy (PLM). Forty-five Wistar rats aged 36-42 days and weighing 200-230 g were assigned to two groups: experimental (n= 25) and control (n= 20). The experimental group received two weekly doses of 1 mg/kg of chemically pure sodium alendronate diluted in distilled water, via gavage, while the animals of the control group received only distilled water. After 60 days, the animals were killed by anesthetic overdose, and the maxillary incisors were extracted and the tibias were removed. The mineral bone density of the tibias was analyzed radiographically and by DXA. The maxillary incisors were subjected to the following evaluations: chemical analysis by IR spectrometry and fluorescence spectroscopy, enamel and dentin CSMH, SEM and PLM. The results were subjected to statistical analysis by the Kruskal-Wallis non-parametric test, using the SAS (Statistical Analysis System) software for Windows version 9.1.3. The significance level was set at 5%. The experimental group presented higher mineral bone density (p<0.05) than the control group, by radiographic optical densitometry and DXA. The chemical analysis by IR spectrometry and fluorescence spectroscopy revealed the presence of alendronate in the mineralized dental structure of the specimens of the experimental group, with a percentage of incorporation of 0.0018% per tooth. The results of enamel and dentin CSMH did not show statistically significant difference between the experimental and control groups (p>0.05). There were no significant morphological differences among the specimens of the groups by SEM and PLM. Based on the obtained results, it may be concluded that the treatment with sodium alendronate caused an increase in the mineral bone density of the proximal tibial metaphysis, and that alendronate was incorporated in the mineralized dental structures without causing significant effects in the enamel and dentin microhardness and morphology of rat incisors.
138

Avaliação da qualidade óssea de bovinos / Assessment of bone quality of bovine

Erbereli, Rogério 18 August 2017 (has links)
A qualidade óssea em grandes animais é avaliada pela densidade mineral óssea (DMO) utilizando a técnica de densitometria óptica em imagens radiográficas; o objetivo desse trabalho foi avaliar e comparar a qualidade óssea baseada na microarquitetura de uma forma inédita. Foram selecionados 20 bovinos, 10 da raça Canchim e 10 da raça Nelore, com controle dos processos biológicos e bioquímicos do nascimento até o abate aos 24 meses de idade, antes de entrarem na fase adulta. O osso metatarsal foi escolhido por suportar maior carga e amostras da diáfise do osso cortical seco foram obtidas. A avaliação da estrutura cristalina de ossos metatarsais secos foi realizada utilizando difração de raios X com a aplicação do método de refinamento de Rietveld, avaliando parâmetros de rede, tamanho de cristalito e microdeformação. A técnica de nanoindentação permitiu avaliar os módulos de elasticidade e valores de nanoindentação. A composição química razão cálcio e fósforo do material, resistência à deformação plástica, valores de microdureza, e imagens de microscopia eletrônica de varredura e microscopia óptica foram realizadas. A comparação entre os resultados das duas raças, Canchim e Nelore, dos valores de parâmetros de rede da estrutura cristalina da hidroxiapatita, tamanho de cristalito, microdeformações, relação cálcio e fósforo, microdurezas Vickers/Knoop, nanodureza Vickers e módulo de elasticidade indicaram que a qualidade óssea das raças Canchim e Nelore é estatisticamente semelhante para 30% dos parâmetros estudados e que para os demais 70% dos parâmetros estudados não há semelhança. / The bone quality in large animals is evaluated by bone mineral density (BMD) using the optical densitometry technique in radiographic images; The objective of this study was to evaluate and compare bone quality based on microarchitecture unpublished. Twenty bovines were selected, 10 from the Canchim breed and 10 from the Nelore breed, with control of the biological and biochemical processes from birth to slaughter at 24 months of age, before entering adulthood. The metatarsal bone was chosen because it supported higher load and samples of the diaphysis of the dry cortical bone were obtained. The evaluation of the crystalline structure of dry metatarsal bones was performed using X - ray diffraction with the application of the Rietveld refinement method, evaluating network parameters, crystallite size and microdeformation. The nanoindentation technique allowed to evaluate the modulus of elasticity and nanoindentation values. The chemical composition calcium and phosphorus ratio of the material, resistance to plastic deformation, values of microhardness, and scanning electron microscopy images and optical microscopy were performed. The comparison between the results of the two races, Canchim and Nelore, of the network parameter values of the hydroxyapatite crystal structure, crystallite size, microdeformations, calcium and phosphorus ratio, Vickers/Knoop microhardness, Vickers nanodness and modulus of elasticity indicated that Quality of the Canchim and Nelore races is statistically similar for 30% of the studied parameters and that for the ofter 70% of the studied parameters there is no similarity.
139

A ação de sucos de frutas sobre materiais restauradores utilizados em lesões cervicais não cariosas / The action of fruit juices upon restorative materials used in noncarious cervical lesions

Cruz, Andréa Ferreira Santos da 07 November 2013 (has links)
O presente estudo in vitro analisou o efeito de 3 sucos de fruta com baixo pH (suco de cupuaçu, taperebá e laranja), e saliva artificial (controle) sobre materiais restauradores indicados em lesões cervicais não cariosas: resina composta nanoparticulada (Filtek Z350 XT), cimento de ionômero de vidro resino modificado (Vitremer) e um cimento de ionômero de vidro convencional (Fuji II). Os materiais foram avaliados, quantitativamente, quanto à alteração de: peso, rugosidade superficial e microdureza superficial, e qualitativamente, por microscopia eletrônica de varredura (MEV). Foram confeccionados 144 corpos de prova para cada teste quantitativo (n=12) e 45 para o MEV (n=3), de (8mm de diâmetro x 2mm de altura). Os corpos de prova foram preparados, mantidos em saliva artificial por 24 h à 37º C, receberam acabamento em politriz, e em seguida foram realizadas as leituras iniciais. Durante um período de 10 dias consecutivos, os corpos de prova foram submetidos ao desafio erosivo (nos respectivos sucos de frutas) durante 30 minutos três vezes ao dia, totalizando 90 minutos/dia e mantidos em saliva artificial entre os intervalos. Após o período de ciclagem erosiva, foram realizadas as leituras finais. Os resultados obtidos foram submetidos ao teste t, ANOVA e Tukey. As médias de alteração entre os valores de peso finais e iniciais demonstraram diferença significativa (p<0,01) nos materiais estudados e em todos os sucos estudados, com exceção do Vitremer quando imerso no suco de taperebá (p>0,01). As médias de alteração entre os valores de rugosidade superficial final e inicial demonstraram diferença significativa (p<0,01) para todos os materiais estudados em todos os sucos, exceto a Filtek Z350 XT no grupo controle que não apresentou diferença significativa (p>0,01). A comparação entre os valores de microdureza final e inicial demonstrou diferença significativa (p<0,01) na microdureza dos materiais estudados em todos os meios de imersão, inclusive no grupo controle. De um modo geral o suco de taperebá foi o que provocou a maior alteração na superfície dos materiais restauradores quanto ao peso, rugosidade, microdureza e na microscopia eletrônica de varredura. A resina composta Filtek Z350 XT foi o material restaurador que menos sofreu alterações de superfície. Concluiu-se que os sucos das frutas estudados são capazes de alterar os materiais restauradores, sendo que a resina composta foi o material que sofreu menor alteração. / This in vitro study examined the effects of 3 fruit juices with low pH (cupuaçu, taperebá and orange) and artificial saliva (control) upon restorative materials indicated in noncarious cervical lesions: nanoparticle composite resin (Filtek Z350 XT), resin-modified glass ionomer cement (Vitremer) and a glass ionomer cement (Fuji II). The materials were evaluated quantitatively as for alterations in weight, surface roughness and surface microhardness, and qualitatively by scanning electronic microscopy (SEM). 144 specimens were prepared for each quantitative test (n = 12) and 45 for the SEM (n = 3), of (8mm diameter x 2mm height). The specimens were prepared, stored in artificial saliva for 24 hours at 37º C, were finished in a polishing machine, and then the initial readings were performed. During a period of 10 consecutive days, the specimens were subjected to erosive challenge (in the respective juices) for 30 minutes, three times a day, and totaling 90 minutes/day and kept in artificial saliva between intervals. After the erosive cycling period, the final readings were taken. The data were analyzed using t test, ANOVA and Tukey.Test The average alterations between the values of initial and final weight showed significant difference (p < 0.01) in the material studied and all the juices studied, except for Vitremer when immersed in taperebá juice (p > 0.01). The average alterations between the values of initial and final surface roughness showed a significant difference (p < 0.01) for all materials studied in all juices, except for Filtek Z350 XT, in the control group, that showed no significant differences (p > 0.01). The comparison between the values of initial and final microhardness showed a significant difference (p < 0.01) in microhardness of the materials studied in all immersion means, including the control group. In general, taperebá juice was the one that caused the biggest alterations in the surface of restorative materials with respect to weight, roughness, hardness and scanning electronic microscopy. The composite resin Filtek Z350 XT was the restorative material that suffered less surface alterations. It was concluded that the fruit juices studied are capable of altering the restorative materials, and composite resin was the material that has undergone minor changes.
140

Tratamento preventivo do esmalte dental exposto à situação de alto desafio cariogênico: estudo in vitro / Preventive treatments of dental enamel exposed to high cariogenic challenge: in vitro study

Mameluque, Soraya 02 October 2014 (has links)
O objetivo do presente trabalho foi avaliar diferentes tratamentos na remineralização do esmalte desmineralizado em situação de alto desafio cariogênico. Foram utilizados 55 fragmentos de esmalte bovino (4mmX4mmX2mm) planificados e polidos. Os espécimes foram cobertos com resina composta ficando exposta apenas a metade da superfície externa (2mmX4mm) e então, foram imersos em solução tampão de acetato (pH 4,7) por 43 horas para formar a lesão de desmineralização. Os espécimes foram divididos aleatoriamente em 5 grupos (n=11), de acordo com os tratamentos preventivos: 1- Controle (sem tratamento); 2- Verniz fluoretado a 5% Duraphat®; 3- Flúor-gel 1,23%; 4- MI PasteTM; e 5- MI Paste PlusTM. Os tratamentos foram realizados uma vez por semana durante 3 semanas. Nos intervalos das aplicações os espécimes foram submetidos a ciclos de pH (DES/RE) num total de 21 dias. Após a finalização da ciclagem os fragmentos foram seccionados longitudinalmente, sendo que em uma metade foi analisada a microdureza longitudinal, pelo cálculo da variação percentual da dureza e na outra metade foi avaliada a profundidade de desmineralização do esmalte através de microscopia óptica. Para a análise em FTIR, pó do esmalte foi obtido dos espécimes em três diferentes momentos: inicial sem desmineralização da superfície, após a desmineralização por 43 horas e após o tratamento. Para análise da microdureza longitudinal empregou-se a variação da dureza. Os dados foram analisados quanto a sua distribuição, porém como não foram normais realizou-se uma análise não paramétrica comparando grupo contra grupo pelo Mann Whitney test com &alpha;=5%. Para análise da profundidade de desmineralização, como os dados se apresentaram normais e homogêneos, realizou-se a análise de variância a 1 critério e teste Holm- Sidak para comparação das médias com &alpha;=5%. Para análise em FTIR fez-se apenas uma análise descritiva dos dados. Na análise dos dados pode-se observar que houve diferença estatística significante entre o grupo controle (G1) com o grupo flúor-gel (G3) (p<0,05), o qual apresentou menor perda de dureza e menor profundidade de desmineralização. Os grupos 2, 4 e 5 foram similares entre si e com o G1 para as duas propriedades analisadas. Na análise da absorbância nos diferentes comprimentos de onda pode-se observar um padrão similar em todas as amostras; a banda de fosfato inicial foi mais larga e posicionada em número de ondas menores. Após a desmineralização, esta banda ficou mais estreita e deslocada para número de ondas maiores. Esse comportamento se repetiu e foi similar para todos os grupo. Baseado nos resultados obtidos pode-se concluir que nenhum dos tratamentos preventivos realizados foi capaz de inibir o processo de desmineralização ou promover a remineralização em situações de alto risco a cárie, embora o flúor-gel tenha permitido uma evolução mais lenta da desmineralização / The aim of this study was to evaluate different treatments on remineralization of demineralized enamel in a high cariogenic challenge. 55 enamel fragments (4mmX4mmX2mm) flat and polished were used. The specimens were covered with composite exposed only half of the outer surface (2mmX4mm) and then were immersed in acetate buffer solution (pH 4.7) for 43 hours to form the demineralization lesion. The specimens were randomly divided into 5 groups (n = 11) according with the preventive treatments: 1 - Control (no treatment); 2 - 5% fluoride varnish Duraphat ®; 3 - Fluoride-gel 1.23%; 4 - MI PasteTM; and 5 - MI Paste PlusTM. The treatments were carried out once a week for 3 weeks. During intervals and among applications the specimens were subjected to pH cycles (DES / RE) for a total of 21 days. After finished of the cycling, the samples were longitudinally sectioned, and one half in the longitudinal microhardness was analyzed and the other half the depth of enamel demineralization using optical microscopy was evaluated. For data analyzed was calculate the percentage change in the hardness. For FTIR analysis, the enamel powder was obtained from specimens at three different times: without demineralization of the surface, after demineralization for 43 hours and after treatment. Data were analyzed for their distribution, but they were not normal there was a non-parametric analysis comparing group versus group by t test (Mann- Whitney test) with &alpha;= 5%. To analyze the depth of demineralization, as the data were normal and homogeneous, we performed analysis of variance criterion 1 and Holm-Sidak test for comparison of means with &alpha;= 5%. For FTIR was realized of descriptive analysis of the data. Data analyzed showed statistically significant difference between the control group (G1) with the fluoride gel group (G3) (p <0.05), which showed less loss of lower hardness and depth of demineralization. Groups 2, 4 and 5 were similar among them and with G1 for two properties analyzed. The analysis of the absorbance at different wavelengths can be observed a similar pattern in all samples; band initial phosphate was wider and placed on the number of smaller waves. After demineralization, this band became narrower and shifted to higher wave number. This behavior was similar for all groups and it is repeated for every group. Based on the results this study it can be concluded that none of the preventive treatment carried out was able to inhibit the demineralization or promote remineralization in high caries risk situations, although fluoride gel has allowed a slow evolution of demineralization

Page generated in 0.0398 seconds