• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 166
  • Tagged with
  • 167
  • 163
  • 153
  • 144
  • 129
  • 38
  • 36
  • 35
  • 35
  • 31
  • 30
  • 28
  • 28
  • 25
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Contribuição ao projeto de dentes de concreto para ligações em estruturas de concreto pré-moldado / Contribution to the design of dapped end beam for connections in precast concrete structures

Caio Cezar Catiste Silva 20 September 2017 (has links)
A presente pesquisa apresenta um estudo comparativo a respeito dos procedimentos para o projeto de dentes de concreto. O dente de concreto é um elemento estrutural bastante utilizado em ligações de estruturas de concreto pré-moldado. Atualmente existem vários procedimentos para o dimensionamento ou estimativa da capacidade resistente dessa ligação, entre os quais destacam-se o da ABNT (NBR 9062 e NBR 6118), PCI, ACI 318-14, Eurocode 2, entre outros. Neste contexto, a presente pesquisa objetiva à análise comparativa desses procedimentos de projeto com resultados experimentais disponíveis. Assim, esses procedimentos de projeto foram aplicados em 38 modelos experimentais de uma base de dados. Normalmente, as ruínas dos dentes de concreto são: a) escoamento da armadura do tirante; b) escoamento da armadura de suspensão; c) ruptura do concreto na região do dente. A relação entre a força de ruína experimental e a força de ruína calculada, designada por Fr,exp/Fr,cal, foi um dos parâmetros utilizados para avaliar as estimativas de força de ruína dos dentes de concreto. Na análise comparativa das estimativas para força de ruína por escoamento da armadura do tirante, a ABNT (NBR 9062 e NBR 6118) apresentou uma média de 1,26 e coeficiente de variação de 16,90%. A ACI 318-14 e o Eurocode 2 forneceram estimativas com uma média de 1,29 e coeficiente de variação de 17,6%. As estimativas do PCI tiveram uma média de 1,12 e coeficiente de variação de 17,9%. Para a ruína por escoamento da armadura de suspensão, as estimativas da ABNT (NBR 9062 e NBR 6118), PCI e ACI 318-14 (Modelos II e III) tiveram uma média de 1,22 e coeficiente de variação de 12,5%. O Eurocode 2 e a ACI 318-14 (Modelo I) apresentaram uma média de 1,87 para as estimativas e coeficiente de variação igual a 17,9%. Para a ruína por ruptura do concreto na região do dente, as estimativas da ACI 318-14 (Modelos II e III) apresetaram uma média de 1,56 e coeficiente de variação de 18,8%. Com o Modelo I, as estimativas da ACI 318-14 tiveram uma média de 1,60 e coeficiente de variação de 19,0%. O Eurocode 2 forneceu estimativas com uma média de 1,63 e coeficiente de variação de 14,6%. O PCI teve a pior estimativa com uma média de 3,29 e coeficiente de variação de 32,4%. O estudo ainda serviu como subsídio para o desenvolvimento de uma proposta para verificação da tensão de compressão no concreto. Para a região do dente, a proposta foi aplicada em 9 modelos experimentais da base de dados e apresentou uma média de 1,33 e um coeficiente de variação de 14,9%. / This research presents a comparative study about procedures for the design of dapped end beam. The dapped end beam is a structural element widely used in connections of precast concrete structures. Currently there are several procedures for the dimensioning or evaluation of the strength capacity of this connection, like as ABNT (NBR 9062 and NBR 6118), PCI, ACI 318-14 and Eurocode 2. In this context, the present research objetives to the comparative analysis of these design procedures with available experimental results. Thus, these design procedures were applied 38 experimental models of a database. Normally, the dapped end beam failures were: a) reinforcement yielding of the tie; b) yielding of the hanger bars; c) concrete rupture in the nib. The relation between the experimental failure force and calculated failure force, designated by Fr,exp/Fr,cal, was one of the parameters used to evaluate the estimates of failure force of dapped end beam. The ABNT (NBR 9062 e NBR 6118) presented an average of 1,26 and a coefficient of variation of 16,90% in the comparative analysis of the estimates for failure by the yielding of the tie. The ACI 318-14 and Eurocode 2 provided estimates with an average of 1,29 and coefficient of variation of 17,6%. The PCI estimates had an average of 1,12 and coefficient of variation of 17,9%. For failure by the yielding of hanger bars, estimates of ABNT (NBR 9062 and NBR 6118), PCI and ACI 318-14 (Models II and III) had an average of 1,22 and a coefficient of variation of 12,5%. Eurocode 2 and ACI 318-14 (Model I) presented an average of 1,87 for the estimates and coefficient of variation equal to 17,9%. For the rupture of concrete in nib, the ACI 318-14 (Models II and III) estimates presented an average of 1,56 and a coefficient of variation of 18,8%. With Model I, the estimates of ACI 318-14 had an average of 1,60 and a coefficient of variation of 19,0%. Eurocode 2 provided estimates with an average of 1,63 and a coefficient of variation of 14,6%. The PCI had the worst estimate with an average of 3,29 and coefficient of variation of 32,4%. The study also served as a subsidy for the development of a proposal for checking the concrete compressive stress. For nib, the simplified proposal was applied in 9 experimental models of the database and presented an average of 1,33 and a coefficient of variation of 14,9%.
112

Contribuição à análise da estabilidade global de estruturas em concreto pré-moldado de múltiplos pavimentos / Contribution in the analysis of global stability of multi-storey precast concrete framed structures

Marcelo Cuadrado Marin 04 December 2009 (has links)
No presente trabalho são avaliados os principais parâmetros de projeto na análise da estabilidade global de estruturas em concreto pré-moldado de múltiplos pavimentos, considerando a não-linearidade física (NLF), não-linearidade geométrica (NLG) e ligações semi-rígidas. Os sistemas estruturais analisados são constituídos por pórticos com ligação viga-pilar semi-rígida e pilares engastados na fundação. As ligações viga-pilar têm sua tipologia definida por chumbadores retos e capa de concreto moldado in loco com armadura de continuidade. A NLF é avaliada segundo a construção dos diagramas M x N x 1/r, onde foi considerado de forma consistente o efeito da força normal, da armadura passiva, da armadura ativa e a reologia do concreto. São propostas funções e definidos coeficientes redutores de rigidez que foram comparados com valores apontados em expressões normativas que contemplam de forma aproximada a NLF. A NLG é avaliada com o auxílio do programa ANSYS e na forma aproximada segundo o coeficiente z e o método da carga lateral fictícia (P-). Apresentam-se modelos analíticos de caracterização de rigidez e resistência de ligações viga-pilar ao momento fletor negativo e positivo. Na análise numérica é feito um estudo de caso completo de uma estrutura típica de múltiplos pavimentos em concreto pré-moldado com o auxílio do programa ANSYS, avaliando-se diferentes formas de consideração da NLF e da NLG. É analisada a distribuição de esforços na estrutura frente às combinações de ações utilizadas e os modelos de comportamento das ligações, para algumas variações de geometria e carregamento. Dentre as conclusões, pode ser citado que os coeficientes redutores obtidos segundo o diagrama M x N x 1/r divergem das indicações normativas para consideração simplificada de NLF. Quanto à consideração simplificada de análise NLG, o coeficiente z apresentou resultados melhores na previsão dos esforços de segunda ordem em relação aos obtidos por 0,95.z. / In this research it was evaluated the main design parameters in the analysis of global stability of multi-storey precast concrete framed structures considering the physical nonlinearity (PNL), geometric nonlinearity (GNL) and semi-rigid connections behavior. The structural systems considered are those consisting of frames with beam-to-column semi-rigid connection and columns inset in the foundation. The beam-to-column connections are defined by two dowels and cast-in-place concrete cap with longitudinal reinforced bars. The PNL is evaluated according the M x N x 1/r diagrams, where are considered the effect of normal force, the reinforcing steel, prestressing steel and creep. Functions are proposed and reducing stiffness coefficients are defined, with were compared with codes that include the approximated PNL. The GNL is evaluated according to ANSYS software by no approximate analisys and its approximate according to the coefficient z and (P-) method. This research presents an analytical model characterization of stiffness and strength of beam-to-column connections to the negative and positive bending moment. In the numerical analysis is made a full case study of a typical multi-storey precast concrete framed structure with the aid of the ANSYS software, evaluating different forms of consideration of the PNL and the GNL. It analysed the bending moment distribution according the combinations of actions used and the behavioral models of connections, for some variations at geometry and loading. The reduction coefficients of flexural rigidity obtained according the M x N x 1/r diagrams differ from normative indications for simplified account of PNL. In GNL simplified analysis, the coefficient z showed better results in predicting the second-order effects with respect to those obtained by the coefficient 0,95. z.
113

Contribuição ao projeto de vigas delgadas de seção \"L\" de concreto pré-moldado / Contribution to the design of precast concrete slender L-shaped beams

Marcus Vinícius Filiagi Pastore 05 August 2015 (has links)
Esta dissertação tem por objetivo contribuir para o projeto estrutural de vigas delgadas de seção \"L\" de concreto pré-moldado, também conhecidas no Brasil como vigas suporte-peitoril. O projeto deste tipo de viga apresenta uma maior complexidade que o de vigas usuais pela seção transversal assimétrica, carregamento excêntrico e as várias possibilidades de ligações viga-pilar e viga-laje. Em função de sua ligação com a laje, o comportamento deste tipo de viga pode apresentar diferentes modelos: a) com torção de equilíbrio; b) sem torção de equilíbrio; e c) com restrição parcial da rotação da laje. É mostrado que para relações altura da viga/largura da mesa inferior maiores que 2,5, a variação da orientação dos eixos principais de inércia com relação aos eixos vertical e horizontal pode ser desprezada. Além disso, o centro de cisalhamento pode ser considerado situado na linha de centro da alma para grandes relações altura da viga/altura da aba. Também são discutidas as ações e efeitos a serem considerados no projeto de vigas de seção \"L\". Em relação ao estado limite último, é mostrado que os procedimentos de dimensionamento de momento fletor e força cortante não diferem dos outros tipos de vigas de concreto, entretanto, o momento de torção pode ser tratado como flexão de placa por um método recomendado na última revisão do ACI-318. O comportamento da ligação alma/aba é considerado como dente de concreto e os seguintes aspectos de seu dimensionamento são apresentados: cálculo do tirante, cálculo da suspensão, cálculo da armadura longitudinal e verificação da biela crítica. Além disso, é levada em conta a resistência à punção da aba para efeito de forças concentradas. Também são discutidas as considerações para a flexão do peitoril que pode ocorrer pela ação lateral do vento e do impacto de veículos. Em relação ao estado limite de serviço, são apresentadas duas situações exclusivas para vigas de seção \"L\" com peitoril alto e delgado: formação de fissuras na extremidade e deformação lateral excessiva. Por fim, um exemplo de aplicação é desenvolvido para ilustrar particularidades no dimensionamento de vigas delgadas de seção \"L\" de concreto pré-moldado. / This thesis aims to contribute to the structural design of precast concrete slender L-shaped beams, also known as facade beams, spandrel beams, L-shaped edge beams and others. The design of these beams shows a greater complexity than usual concrete beams due to the asymmetric cross section, eccentric loads and the various possibilities for beam-column and beam-slab connections. According to their connection with the slab, the beam behavior can be divided into different models: a) with equilibrium torsion; b) without equilibrium torsion; c) with partial restriction of the slab rotation. It is shown that for height-to-total width ratios larger than 2.5, the variation of the orientation of the principal axes with respect to the vertical and horizontal axes can be neglected. Furthermore, the shear center can be considered located at the web center line for high values of the beam height-to-ledge height ratio. It is also discussed the actions and effects to be considered in the design of L-shaped beams. Regarding the ultimate limit state, it is shown that the bending moment and shear force procedures do not differ from other types of concrete beams, however, the torsion can be treated as plate bending by a recent method recommended in the latest ACI-318 revision. The ledge is considered as dapped end beams and the following aspects of its design are presented: transverse bending; hanger requirements; longitudinal bending and shear strength, including punching shear. It is also discussed the considerations for web flexure that may occur by wind action and lateral vehicle impact. Regarding the serviceability limit state, it is presented two unique situations for precast concrete slender L-shaped beams: crack formation at end regions and excessive lateral deflection. Lastly, an example is developed to illustrate particularities of the precast concrete slender L-shaped beam design.
114

Estudo experimental de uma ligação viga-pilar em concreto pré-moldado utilizando perfis metálicos e solda / Experimental study of a precast concrete beam-column connection using welded steel shapes

André Marcon Trotta 03 September 2012 (has links)
Nesta pesquisa estudou-se o comportamento de uma ligação viga-pilar em concreto pré-moldado utilizando perfis metálicos embutidos nos elementos estruturais. O modelo da ligação estudada permite a transmissão de momentos fletores positivo e negativo. Para a continuidade de momento fletor negativo, utilizam-se um consolo metálico com seção \"U\" embutido no pilar e dentes metálicos com seção tubular retangular embutidos nas vigas, soldados. Para a continuidade de momento positivo, utilizam-se cantoneiras metálicas embutidas no pilar que são soldadas à armadura positiva da viga. O estudo consistiu em análise experimental de um modelo cruciforme em duas etapas. Na primeira etapa o modelo foi solicitado a carregamentos cíclicos reversíveis por meio de um atuador servo hidráulico acoplado sobre o topo do pilar. Na segunda etapa, o modelo foi solicitado a carregamento estático monotônico por meio de macacos hidráulicos dispostos sob o pilar para causar a ruptura com momento negativo. O modelo apresentou uma considerável facilidade de montagem, já que na fase transitória a ligação é articulada e o consolo do pilar em perfil \"U\" permite a estabilidade lateral da viga. O consolo metálico embutido no pilar escoou muito antes de atingir a capacidade resistente dos outros componentes da ligação, pois na seção da ligação junto à face do pilar, apenas o consolo resiste à flexão. / In this research the behavior of a beam-column connection in precast concrete system using welded steel shapes built-in structural elements was studied. The model of the studied connection allows transmission of positive and negative moments. For the continuity of negative moment, is used a steel \"U\" shaped corbel inserted in the column welded with tubular section steel hangers inserted in each beam. For the continuity of positive moment, use is made of metal embedded in abutment ledges that are welded to the positive reinforcement of the beam. The study consisted on experimental analysis of a cross-shaped specimen in two steps. In the first step was applied to the specimen a cyclic load using hydraulic actuator coupled to the column head. In the second step was applied in the specimen a static load using hydraulic jack positioned under the column to cause rupture with negative moment. The connection model showed a considerably easy assembly, as in the transitional phase the connection is articulated and the steel \"U\" shaped corbel of the column allows the lateral stability of the beam. The rupture occurred by yielding of the steel U shaped corbel in the section near the column. The steel corbel inserted in the column yielded before reaches the resistant capacity of other components of the connection, because of the section in the connection close of the column, only steel corbel resists the negative moment.
115

Comportamento de chumbadores grauteados de ligações viga-pilar parcialmente resistentes a momento fletor / Behavior of grouted dowel of partial moment resistant beam-to-column connections

Eduardo Aurélio Barros Aguiar 05 May 2010 (has links)
Neste trabalho estudou-se o comportamento dos chumbadores grauteados, usados em ligações viga-pilar parcialmente resistentes a momento fletor. O foco da pesquisa foi a análise teórica e experimental do mecanismo resistente do chumbador inclinado. O programa experimental englobou 15 modelos, sendo que as variáveis analisados foram: a) diâmetros dos chumbadores, de 16 mm, 20 mm e 25 mm; b) inclinações dos chumbadores, de 0º (chumbador normal à interface), 45º e 60º; c) resistência à compressão do concreto adjacente ao chumbador, sendo usado concreto das classes C35 e C50; d) aplicação de força de compressão normal à interface. Os resultados experimentais indicaram aumentos significativos tanto na capacidade última quanto na rigidez a cisalhamento do chumbador. Foram realizadas simulações numéricas, onde foi verificada a sensibilidade dos resultados aos parâmetros inerentes à interface concreto - almofada de apoio, sendo desenvolvidas expressões para estimar tais parâmetros. Com base na análise experimental e em análises numéricas, foram propostos modelos analíticos que conseguiram representar de forma satisfatória a influência da inclinação e demais parâmetros analisados no mecanismo resistente do chumbador. / This research deals with the behavior of grouted dowels, used in partial moment resistant beam-to-column connections. The focus of the research was the theoretical and experimental analysis of dowels resistant mechanism. The experimental program include 15 models, and its variables analyzed were: a) the dowel diameter of 16 mm, 20 mm and 25 mm; b) the dowel inclination of 0° (dowels perpendicular to the interface), 45° and 60°; c) compressive strength of concrete adjacent to the dowels of classes C35 and C50, d) application of compression load, normal to the interface. Experimental results indicated significant increases in ultimate capacity and the shear stiffness of the dowels. Numerical simulations were carried out which identified the sensitivity of results to the parameters of the interface concrete bearing pad, and developed expressions to estimate such parameters are given. Based on experimental and numerical analysis analytical models have been proposed that could adequately represent the influence of inclination and other parameters in the mechanism resistant dowels.
116

Ligações de montagem viga-pilar para estruturas de concreto pré-moldado: estudo de caso / Assembly connections beam-column for structures of precast concrete: case study

Lisiane Pereira Prado 19 September 2014 (has links)
A pesquisa em questão é direcionada ao estudo de uma ligação provisória entre o pilar e a viga pré-moldada para que possa servir de suporte durante a execução da ligação de estrutura, que consiste na utilização de barras de aço salientes do pilar e da viga, traspassando entre si, finalizada por concreto com adição de fibras. O uso de consolo metálico formado por perfil tipo \"U\" e dente metálico constituído de um perfil de seção retangular vazado foi o método proposto para a ligação provisória, na qual a montagem da viga no pilar se dá pelo encaixe dos elementos. O modelo adotado como dente metálico é denominado \"Cazaly Hanger\". Para avaliar o comportamento da ligação estudada foram analisados os modelos analíticos referentes aos elementos da ligação e, posteriormente, foi montado um pórtico estrutural com a ligação provisória em estudo, para analisar o seu comportamento sob um carregamento estático e monotônico. Inicialmente foi aplicada uma força referente a 71,75% da capacidade da ligação, no meio do vão da viga e excêntrico ao seu eixo para analisar a torção na ligação, simulando uma possível força acidental que venha a ocorrer durante a montagem dos elementos. Na segunda etapa foi aplicada uma força a 1/2,94 do vão da viga a fim de determinar a capacidade do dente metálico e, na terceira e última etapa, o carregamento foi aplicado a 1/7,14 do vão da viga, na extremidade oposta a força aplicada na etapa 2, para determinar a capacidade de suporte do consolo metálico. Os resultados dos ensaios mostraram que a capacidade resistida pelo dente metálico foi 33% maior que o determinado no modelo analítico e, o estado limite último do consolo metálico constituído por perfil \"U\" foi caracterizado pela deformação excessiva da alma, na região superior do consolo. Pode-se concluir que o modelo de cálculo usado no trabalho foi coerente com os resultados encontrados para o dente metálico, mas, para os consolos metálicos, os valores teóricos não foram compatíveis com os resultados encontrados no modelo prático. / The research is directed to the study of a beam-column temporary connections to provide support during the execution of structure connection, which consist on using steel bars protruding from the column and beam finalized by addition of concrete with fibers. The use of steel \"U\" shaped corbel in the column and a steel hangers rectangular hollow core section in the beam was proposed for temporary connection method, in which the erecting the beam in the columns occurs by the nest of the elements. To evaluate the behavior of the studied connections it was analyzed the analytical models of connections and, after were building a structural portico with the connection to analyze their behavior under static and monotonic loading. Initially it was applied a load corresponding to 71,75% of the connection capacity, mid-span of the beam and its eccentric to check the torsion moment on the connection, simulating a possible live load that may occur during assembly of the elements. In the second stage was applied a load of 1/2,94 span beam to determine the capacity of steel hanger rectangular hollow core section and the third and last step the load was applied at 1/7,14 span of the beam, the end opposite the load applied in step 2, to determine the ability of the steel \"U\" shaped corbel. The results showed that the steel hanger inserted capacity was 33% higher than determined in the analytical model and the ultimate limit state of the steel \"U\" shaped corbel was characterized by excessive deformation of vertical plate, in the upper region of corbel. Can conclude that the calculation model used in the study was consistent with the results found for the steel hangers rectangular hollow core section, but for the steel \"U\" shaped corbel, the theoretical values were not consistent with the results found in practical model.
117

Instabilidade lateral de vigas pré-moldadas em situações transitórias / Lateral stability of precast concrete beams during transient situations

Pablo Augusto Krahl 30 April 2014 (has links)
O objetivo desta pesquisa é apresentar procedimentos de verificação da estabilidade lateral de vigas de concreto em situações transitórias e com eles realizar análises paramétricas. As fases transitórias estudadas são içamento, transporte e pré-serviço com e sem contraventamento nos apoios. As formulações apresentadas contém cálculo de carga crítica de instabilidade lateral, momento crítico e fator de segurança. São apresentados exemplos numéricos e a partir deles realizadas análises paramétricas com intuito de determinar limites de segurança. Os parâmetros variados foram fck, imperfeições geométricas, vão, largura da mesa comprimida e espessura da alma fazendo uma comparação entre vigas I e retangular. Com os resultados, foram obtidas esbeltezes geométricas limite para fases transitórias, relações entre carga crítica e carga devido ao peso próprio e uma relação entre momento crítico elástico e momento último de flexão para a fase transitória anterior à execução do tabuleiro com contraventamento nos apoios, especificamente. Na comparação entre vigas I e retangular, constatou-se que os dois tipos de seção apresentam limites de segurança distintos. As análises mostraram que os limites de esbeltez geométrica recomendados, como lh/bf², geram elementos, de seção transversal I, muito esbeltos. Este parâmetro apresentou uma variação significativa na tentativa de determinar limites nas análises paramétricas. Portanto, pode ser conservador adotar como limite a menor esbeltez obtida nas análises. Conclui-se que a verificação da segurança por esbeltezes geométricas nem sempre é adequada, pois não são considerados parâmetros como imperfeições geométricas e fck que mostraram serem importantes nas análises paramétricas. A esbeltez representada pela razão entre momento último e momento crítico de instabilidade elástico é mais abrangente e a busca por um valor limite deste parâmetro apresentou resultados com pouca variação para as vigas I. Com relação ao limite clássico de segurança que recomenda uma carga crítica maior que quatro vezes a carga de peso próprio, os resultados mostraram que esta recomendação é conservadora. As análises paramétricas mostraram que para vigas I esta razão igual a dois e meio atende a segurança destes elementos. / The objective of this research is to present a contribution to the verification of lateral stability of concrete beams in transient situations through parametric analyzes. The transient phases studied are lifting, transportation and prior to execution of the deck with braced and unbraced supports. Formulations presented contain calculation of buckling load, buckling moment and factor of safety. Numerical examples are presented and parametric analyzes are performed from these aiming to determine safety limits. The varied parameters were fck, geometric imperfections, span, compression flange width and web width by making a comparison between I-beams and rectangular beams. With the results, slenderness limits were obtained for transient phases, relationships between critical load and load due to self-weight and a relationship between elastic critical moment and ultimate moment to the transient situation before the execution of the deck with braced supports, specifically. In the comparison between I-beams and rectangular beams, it was found that the two types of section present different safety limits. Analyzes showed that the geometric slenderness limits recommended, as lh/bf², generate slender elements of I cross section. This parameter showed a significant variation in an attempt to determine limits on parametric analyzes. Therefore adopt the lower slenderness limit obtained in analyzes may be conservative. It is concluded that the safety verification by geometric slenderness is not always adequate, because they do not consider parameters such as geometric imperfections and fck that showed to be important in the parametric analyzes. The slenderness ratio represented by the ultimate moment and elastic critical moment of instability is more comprehensive and the search for a limiting value of this parameter presented results with little variation for the I-beams. With respect to the classical limit of safety which recommends that the critical load is greater than four times the self-weight load, the results showed that this recommendation is conservative. Parametric analyzes showed that for I-beams this ratio equal to two and a half addresses the safety of these elements.
118

Almofada de apoio de compósito de cimento para ligações em concreto pré-moldado / Bearing pad of cement composite for connections in precast concrete

Gustavo Henrique Siqueira 30 March 2007 (has links)
Esta pesquisa apresenta um estudo de uma argamassa modificada para uso como elemento de ligação entre elementos de concreto pré-moldado. A argamassa utilizada nesta pesquisa é obtida pela introdução de látex estireno-butadieno (SB) e fibras de polipropileno a uma argamassa de cimento e areia. Estas adições modificam suas propriedades mecânicas, proporcionando o aumento da deformabilidade por diminuição do módulo de elasticidade do compósito, conferindo-lhe características favoráveis ao uso como elemento de apoio para elementos pré-moldados de concreto. Foram realizados ensaios de caracterização do compósito por meio da obtenção das resistências à compressão e à tração e, do módulo de elasticidade para corpos-de-prova cilíndricos com 50 mm de diâmetro com 100 mm de altura. Ensaios de capacidade de deformação, capacidade de rotação e capacidade de acomodação de imperfeições e distribuição das tensões foram realizados em almofadas de 150 mm x 150 mm com espessura de 10 mm. Os resultados mostraram que o material possui boa capacidade de se deformar em níveis de tensão da ordem de 10 a 20 MPa mantendo sua resiliência. Valores de rotações entre 0,01 e 0,02 rad foram obtidos nos ensaios, sendo estas maiores que os valores necessários para a maioria dos casos convencionais de projeto. Na acomodação e distribuição das tensões, a presença das almofadas promoveu uma melhora de 25% no desempenho de ligações submetidas à compressão uniforme, com rugosidades de 1,0 mm. / This research presents a study of a mortar modified to use as bearing pad between precast concrete elements. The mortar used in this research is achieved by the introduction of styrene-butadiene latex (SB) and polypropylene fibers into a cement mortar and sand, modifying their mechanical properties, as increase of the potential deformation by decrease of the composite modulus of elasticity, providing favorable characteristics to the use as bearing pad for precast concrete elements. Cylindrical samples of 50 mm of diameter with height of 100 mm were molded and tested to determination the compressive and the tensile strength and also the modulus of elasticity of the composite. Compression tests with cushions of 150 mm x 150 mm of base with thickness of 10 mm were done to determinate the deformation capacity, rotation capacity and capacity of accommodation of imperfections and distribution of the stresses between precast elements. The results showed that the material has a capacity to deform in levels of tension from 10 to 20 MPa maintaining his resilience. Values of rotations among 0,01 and 0,02 rad were obtained, being these larger ones than the necessary values for most of the conventional cases of project. In the accommodation and distribution of the stresses, the presence of the bearing pad promoted an improvement of 25% in the strength of connections subject to uniform compressive stresses, with surface irregularities of 1,0 mm.
119

Análise estrutural de pórticos planos de elementos pré-fabricados de concreto considerando a deformabilidade das ligações / Structural analysis of precast concrete portal frames considering the semi-rigid behavior of the connections

Anamaria Malachini Miotto Soares 19 June 1998 (has links)
Os sistemas pré-fabricados vêm conquistando espaço em todo o Brasil. Dentre eles, os pórticos planos de elementos pré-fabricados de concreto com sistema estrutural para telhado de duas águas, comumente denominados de galpões, tem sido amplamente aplicados. Os galpões, como a matona das estruturas pré-moldadas de concreto, apresentam suas ligações, em maior ou menor grau, deformáveis. Portanto, este trabalho refere-se ao estudo da deformabilidade de uma de suas ligações: a ligação viga-pilar executada através de consolo e chumbador, e da sua influência na distribuição dos esforços solicitantes destas estruturas. Neste sentido, foram realizadas simulações numéricas, com o emprego do Método dos Elementos Finitos e ensaios físicos. Através do ensaio físico realizado no modelo da ligação viga-pilar foi possível determinar sua deformabilidade à flexão e observar seu modo de ruptura. As simulações numéricas foram realizadas tanto para obter teoricamente o valor da deformabilidade à flexão da ligação em análise, como para avaliar sua influência no comportamento estrutural dos galpões pré-moldados. Com base nos resultados obtidos, foram elaboradas algumas recomendações de projeto para os galpões pré-moldados. / The use of precast concrete structures has increased in Brazil. Among them, the precast concrete portal frames with sloping beams have been extensively used in storehouses and commercial and industrial buildings. This type of portal frame, as the most precast concrete structures, has semirigid connections. So, this work deals with the study of the semi-rigid behavior of one beam-column connection type frequently used in these structures. In this kind of connection the beam rests on a corbel which has two projecting bolts connecting it. The aim of this thesis is also to determine the influence of the flexibility connection on the structure behavior. Numerical modeling applying the Finite Element Method and experimental tests were done to analyse these aspects. The test results of a beam-column model allowed the construction of the moment-rotation diagram and the failure mode observation. The numerical modeling was done to get the value of the connection flexibility and to study its influence on the precast concrete portal frame behavior. Based on the results some design recommendations were established.
120

Estudo de cálice de fundação com ênfase nos esforços nas paredes transversais do colarinho / Study of the socket base foundation with emphasis on the efforts of transverse walls

Vinicius César Pereira Nunes 08 May 2009 (has links)
Este trabalho apresenta uma análise da ligação pilar-fundação por meio de cálice em estruturas de concreto pré-moldado, focando os esforços nas paredes transversais do colarinho. No programa experimental foram ensaiados dois protótipos submetidos à flexão com grande excentricidade: um com interface pilar-colarinho lisa e o outro com interface rugosa por meio de chaves de cisalhamento. Foi adotado um detalhamento diferenciado para as armaduras verticais principais concentrando as mesmas próximas aos cantos, bem como foi adotada, para o colarinho, uma espessura inferior à recomendada pela literatura técnica. Com os resultados experimentais foi possível analisar a resistência dos protótipos, as deformações das armaduras e os deslocamentos das paredes. Foi realizada uma análise dos resultados experimentais com um modelo de cálculo da literatura técnica, no que diz respeito às forças resultantes nas armaduras verticais principais e nas armaduras horizontais principais situadas nas paredes transversais do colarinho, considerando duas situações distintas de comportamento para as paredes transversais: flexo-tração e tração. Em função dos resultados foi verificado que as armaduras verticais situadas próximo aos cantos contribuíram efetivamente para a resistência do protótipo com interface lisa. Comprovou-se que as paredes transversais foram submetidas a uma flexo-tração e que o modelo teórico aplicado considerando 15% de flexão e 85% de tração apresenta os melhores resultados, se comparados com os valores obtidos experimentalmente. / This research presents an analysis of socket base connections of precast concrete structures, with emphasis on the e orts of transverse walls. In the experimental program were tested two prototypes subjected to bending with great eccentricity: one with smooth interface, and other with rough interface through shear keys. It adopted a different detail for main vertical reiforcement, concentrating them around the corner, and was adopted for the socket, a thickness less than that recommended by the technical literature. Based on experimental results were performed the analysis of the strenght of prototypes, the deformations of the reinforcement, and the deflection of the walls. It was performed an analysis of experimental results with a design model of the technical literature regarding to the forces resulting in main vertical and horizontal reinforcement located on the transverse walls of socket, considering two different situations of behavior to transverse walls: bending-tension and tension. Analyzing the results, it was verified that the vertical reinforcement located near the corners effectively contributed to the strength of the prototype with smooth interface. It has been proved that the walls were subjected to a bending tension and that the theoretical model applied with 15% of bending and 85% of tension gives the best results, when compared with the values obtained experimentally.

Page generated in 0.1037 seconds