• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Conception d'un biocapteur basé sur la photoluminescence du GAAS (001) pour la détection de micro-organismes

Duplan, Valérie January 2011 (has links)
Pendant que la menace potentielle du bioterrorisme augmente, il y a grand besoin d'un outil qui peut détecter les agents biologiques contaminants dans l'environnement de façon rapide, fiable et précise. Par contre, les méthodes traditionnelles utilisées nécessitent l'utilisation de laboratoires d'analyse sophistiquée, souvent dans des installations centralisées, ce qui demande un capital considérable et une main-d'oeuvre hautement qualifiée. Il est possible de développé des dispositifs basés sur les biocapteurs à faible coût et très efficace à la détection d'agents biologiques. De plus, ils peuvent être utilisés dans d'autres domaines, au jour le jour, tel pour la surveillance de contaminants dans les produits comestibles. Dans le but de résoudre ce problème, une nouvelle approche pour la fabrication d'un biocapteur optique a été développée. Celui-ci serait capable de détecter, de façon directe, des micro-organismes qui seraient immobilisés à sa surface plus rapidement et plus aisément qu'avec les méthodes conventionnelles. En effet, les expériences présentées visent la fabrication d'un biocapteur suite à la déposition de molécules biochimiques sur une hétérostructure de GaAs/ALGaAs. Le biocapteur ainsi produit tire parti de la photoluminescence émise par ce semi-conducteur quantique III-V pour la détection de microorganismes immobilisés spécifiquement et négativement chargés. La présente recherche est basée sur des techniques novatrices de biocapteurs pour lesquelles il existe peu de littérature. Les travaux expérimentaux et les explications théoriques se révèlent ainsi de nature très exploratoires. Les résultats préliminaires obtenus ont d'ailleurs été similaires aux prédictions initiales. De plus, les détails théoriques et explications physiques permettent de comprendre l'origine des résultats obtenus et d'établir, de manière convaincante, les procédures à suivre pour une architecture optimale. Je rapporte ainsi l'étude de la bio-fonctionnalisation du GaAs (001) visant l'immobilisation d'anticorps polyclonaux selon deux architectures différentes. De plus, les architectures proposées ont leurs régions actives ouvertes à l'environnement, pour permettre des mesures en continues et, en plus d'être des systèmes offrant la possibilité de multiplexage, offrent un potentiel de mesures en parallèle, pour un grand nombre de mesures en simultanées. Les résultats obtenus démontrent l'immobilisation réussie ainsi que la détection effectuée du virus de l' influenza A et des bactéries Escherichia coli et Legionella pneumophila respectivement. Enfin, les avantages et les limites de chaque architecture ont ensuite été détaillés.
2

Elaboration de Nouveaux Matériaux d'Electrodes obtenus par Autoassemblage de Polyélectrolytes, Nanoparticules et Biomolécules : Etudes physico-chimiques et applications.

Fatisson, Julien 25 October 2005 (has links) (PDF)
La thèse décrit la caractérisation physico-chimique et les applications électroanalytiques de nouveaux matériaux nanocomposites, déposés sur des surfaces d'électrode par autoassemblage électrostatique de polyélectrolytes (PE), d'enzymes et de nanoparticules d'or (NP).<br />La croissance de ces films multicouches fut suivie in situ par spectroscopie et microgravimétrie. L'électrochimie a permis de quantifier le processus de transfert d'électron, la perméabilité des films et la cinétique électroenzymatique. Des relations structure-propriétés furent établies par modélisation cinétique et structurale.<br />La glucose oxydase et la polyphénol oxydase furent assemblées sur des électrodes d'or et de carbone vitreux avec le polydiallyldimethylammonium et le chitosane. L'assemblage de NP et de PE redox, à base de complexe d'osmium ou de viologène, conduit à des films nanocomposites dont les propriétés de conduction électronique furent caractérisées et appliquées au développement de transducteurs.
3

Amélioration de la compréhension des transferts électroniques dans les électrolytes hautement concentrés

Généreux, Simon 08 1900 (has links)
Les travaux de la thèse portent sur l’impact de la structure des électrolytes hautement concentrés (ÉHC) à base de Lithium Bis[trifluorométhane(sulfonyl)]imide (LITFSI) et d’acétonitrile (ACN) dans les réactions de transfert d’électron et les interactions présentes avec les différentes espèces en jeu. Ces électrolytes sont étudiés comme électrolyte dans les dispositifs de stockage d’énergie (batteries, supercapaciteurs), mais la recherche sur les transferts d’électron dans ces ÉHC est presque inexistante. Les travaux sont présentés en deux volets; dans le premier, nous nous sommes concentrés à assurer de la qualité des ÉHC. Nous avons identifié les principales sources d’eau dans ces électrolytes : la présence d’eau varie selon le fournisseur de sel et le taux d’adsorption d’eau de l’électrolyte. Nous avons aussi analysé les impacts de la quantité d’eau sur les propriétés physicochimiques et la fenêtre de stabilité électrochimique. Une teneur d’eau dans les ÉHC sous 1000 ppm n’affecte pas les propriétés physicochimiques. Cependant, la fenêtre de stabilité électrochimique est affectée par une faible présence d’eau (>200 ppm), particulièrement la stabilité en réduction. Le second volet porte sur l’étude du transfert d’électron du couple Fc+/Fc dissout et adsorbé à l’électrode dans les ÉHC LiTFSI : ACN. Nous avons montré que la cinétique du transfert d’électron varie avec la concentration (dilué vs. hautement concentré) et avec l’état d’oxydation du couple rédox (Fc+ vs Fc). La constante de transfert d’électron est plus élevée avec le Fc+ que le Fc dans les milieux dilués, mais la situation est inversée dans les ÉHC. En complément à l’électrochimie, les études Raman couplées à l’électrochimie ont révélé que cette différence provient de l’environnement chimique qui diffère entre les deux espèces, dues à la charge des deux espèces (Fc+ vs. Fc) aux différentes concentrations de sel. Les travaux de cette thèse sont les premiers à montrer l’électrochimie d’une molécule électroactive couplée avec l’utilisation de méthode spectroscopique pour le couple Fc+/Fc dans les ÉHC. Cette recherche ouvre la porte à l’utilisation de ces méthodes d’analyse pour les ÉHC et montre un grand potentiel pour des applications autre que le stockage d’énergie. Les résultats obtenus sont un premier pas vers la formulation d’ÉHC adaptés aux applications d’électrocatalyse : l’utilisation des interactions électrostatiques présentes à haute concentration pourraient ralentir les réaction secondaires formant des cations ou ralentir la diffusion de cations impliqués dans les réactions de transfert d’électron couplées. / The work of this thesis focuses on the impact of the structure of highly concentrated electrolytes (HCE) based on Lithium Bis[trifluoromethane(sulfonyl)]imide (LITFSI) and acetonitrile (ACN) on the electron transfer reactions and the interactions present with the different species involved. These electrolytes are studied as electrolytes in energy storage devices (batteries, supercapacitors), but research on electron transfers in these HCE is almost non-existent. The work is presented in two parts; in the first part, we focused on ensuring the quality of HCE. We identified the main sources of water in these electrolytes: the presence of water varies depending on the salt supplier and the water adsorption rate of the electrolyte. We also analyzed the impacts of the amount of water on the physicochemical properties and the electrochemical stability window. A water content in HCE below 1000 ppm does not affect the physicochemical properties. However, the electrochemical stability window is affected by low water content (>200 ppm), especially the reduction stability. The second part deals with the study of the electron transfer of the dissolved and adsorbed Fc+/Fc couple at the electrode in LiTFSI: ACN HCE. We have shown that the electron transfer kinetics varies with concentration (dilute vs. highly concentrated) and with the oxidation state of the redox couple (Fc+ vs. Fc). The electron transfer constant is higher with Fc+ than Fc in dilute media, but the situation is reversed in HCE. In addition to electrochemistry, Raman studies coupled with electrochemistry revealed that this difference in electron transfer comes from the chemical environment which differs between the two species, due to the charge of the two species (Fc+ vs. Fc) at different salt concentrations. The work of this thesis is the first to show the electrochemistry of an electroactive molecule coupled with the use of spectroscopic methods for the Fc+/Fc couple in HCE. This research opens the door to the use of these analytical methods for HCE and shows a great potential for applications other than energy storage. The results obtained are a first step towards the formulation of HCE adapted to electrocatalysis applications: the use of electrostatic interactions present at high concentration could slow down the secondary reactions forming cations or slow down the diffusion of cations involved in coupled electron transfer reactions.
4

Développement d’outils analytiques pour la détection de biomolécules directement dans des fluides sanguins

Breault-Turcot, Julien 09 1900 (has links)
Cette thèse porte sur le développement de biocapteurs basés sur la technique de résonance des plasmons de surface (SPR) pour effectuer des analyses directement dans un fluide sanguin n’ayant subi aucune purification ou dilution. L’ensemble des biocapteurs discutés exploiteront un instrument SPR portable développé dans le groupe du professeur Masson. Le premier volet de la thèse portera sur le processus d’interférence lié à l’adsorption non spécifique du sérum à la surface du capteur. L’analyse des biomolécules adsorbées sera effectuée en combinant la SPR à la spectrométrie de masse. Les informations obtenues seront exploitées pour la construction de biocapteurs adaptés à l’analyse en milieu sanguin. Un premier biocapteur développé ciblera la protéine antigène prostatique spécifique (APS) contenue dans le sérum servant de biomarqueur pour dépister le cancer de la prostate. Pour détecter les faibles concentrations de cette protéine directement dans le sérum, un matériel plasmonique microstructuré sera utilisé pour amplifier les signaux obtenus et sera recouvert d’une monocouche peptidique minimisant l’adsorption non spécifique du sérum. L’instrument SPR aura été adapté pour permettre également la détection simultanée de fluorescence. Un test ELISA sera ainsi effectué en parallèle du test SPR. Chacune des techniques fournira un contrôle pour la deuxième, tout en permettant de détecter le biomarqueur au niveau requis pour dépister la maladie. La combinaison des deux méthodes permettra aussi d’élargir la gamme dynamique du test de dépistage. Pour terminer, l’instrument SPR portable sera utilisé dans le cadre de détection de petites biomolécules ayant un potentiel thérapeutique directement dans un échantillon de sang. Des peptides ayant une activité anti-athérosclérotique pourront ainsi être détectés à même un échantillon de sang ni purifié ni dilué, et ce à des concentrations de l’ordre du micromolaire. Une modification de la microfluidique via l’introduction d’une membrane poreuse au cœur de celle-ci sera la clé permettant d’effectuer de telles analyses. La présente thèse met de l’avant de nouvelles stratégies et des modifications instrumentales permettant d’analyser des protéines et des petites molécules directement dans un échantillon non purifié de sérum ou de sang. Les modifications apportées au système fluidique, à l’instrument SPR et au niveau du biocapteur employé permettront d’effectuer des biodétections dans des matrices aussi complexes que les fluides sanguins. Les présents travaux mettent en lumière la capacité d’un instrument SPR/fluorescence portable à faire en 12 minutes la biodétection d’un marqueur du cancer de la prostate directement dans un échantillon de sérum. Finalement, on rapporte ici un des premiers articles où un biocapteur SPR est utilisé à même un échantillon de sang non-purifié pour faire des biodétections. / This thesis discusses the development of surface plasmon resonnance (SPR) biosensors to perform detection directly on unpurified and undiluted blood based fluids such as serum or blood. Every biosensor discussed in the following chapters rely on a home-built portable SPR device developed in Professor Masson’s research laboratories. Non-specific adsorption, which greatly hinders biosensing in crude fluids, will be the first topic of the thesis. Serum adsorption was performed on the SPR sensor surface and then characterized by SPR and mass spectrometry. This study provided useful information for biosensing directly in blood-based fluids. It also provided a better fundamental understanding of the nonspecific adsorption process on surfaces. The first biosensor was developed to detect prostate specific antigen (PSA), a protein normally contained in serum, which is a known biomarker for prostate cancer. In order to detect low concentrations of this protein directly in serum, a microstructured gold film was used to amplify the signal generated by the binding event on the biosensor. A peptide monolayer covered the metallic surface of the sensor to reduce non-specific protein adsorption. The SPR portable instrument was modified to simultaneous detect fluorescence in order to perform a SPR and ELISA test in a single instrumental platform. Each technique provided a control for the other for detection of the prostate cancer biomarker at concentration levels required for the screening of the disease. The SPR and ELISA combination also extended the dynamic range of the biosensing assay. Finally, the portable SPR device was used to detect small biomolecules with potential therapeutic activity directly in a sample of blood. Peptides with an anti-atherosclerotic activity were thus detected in an unpurified and undiluted blood sample at micromolar concentration. The addition of a porous membrane to the microfluidic used for the biosensing assay facilitated the successful detection of these molecules in whole blood. The present thesis describes novel strategies and instrumental modifications to unlock the possibility of performing biosensing directly on unpurified and undiluted blood-based fluids. Modifications of the fluidic system, the SPR instrument and biosensor used will allow detection in fluids with high complexity such as serum or blood. The work described herein reports a prostate cancer screening assay performed in 12 minutes directly in serum using a portable SPR/fluorescence instrument. Finally, this thesis reports one of the first scientific papers where a SPR biosensor is used to perform analysis directly in blood.

Page generated in 0.0895 seconds