1 |
Análise toxicológica por técnicas de triagem aplicada em amostras biológicas post-mortem de casos suspeitos de intoxicação provenientes de Instituto de Criminalítisca / Systematic toxicological analysis by screening techniques applied in pos-mortem biological samples of suspected cases of poisning from Institute of ForensicSilva, Maria Augusta Alves 12 February 2014 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2015-04-23T13:12:37Z
No. of bitstreams: 2
Dissertação - Maria Augusta Alves Silva - 2014.pdf: 3616508 bytes, checksum: ff3549d426c3e4da5a2e979383c5aa23 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2015-04-23T13:15:41Z (GMT) No. of bitstreams: 2
Dissertação - Maria Augusta Alves Silva - 2014.pdf: 3616508 bytes, checksum: ff3549d426c3e4da5a2e979383c5aa23 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2015-04-23T13:15:41Z (GMT). No. of bitstreams: 2
Dissertação - Maria Augusta Alves Silva - 2014.pdf: 3616508 bytes, checksum: ff3549d426c3e4da5a2e979383c5aa23 (MD5)
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
Previous issue date: 2014-02-12 / The toxicological analyzes on various samples are extremely important and can be used for multiple purposes, such as monitoring of drug addicts, forensic analysis, doping control, therapeutic monitoring, analyses of environmental contaminants, etc. The objective of this study was to analyze post - mortem blood samples of the Instituto de Criminalística de Goiás (IC) by immunochromatography and systematic toxicological analysis HPLC - PDA to check the presence or absence of toxic agents. The chromatographic conditions of the method were: mobile phase monobasic potassium phosphate buffer pH 2.3 and acetonitrile, flow rate 1 ml / min, Lichrospher RP8 column, 5μm, 250 x 4.0 mm, scanning range 200-380 nm, the calibration standards were MPPH system, caffeine, benzene and histamine. It was used the database proposed by UVTOX Pragst et al (2001). As part of the partial validation the matrix effect was evaluated by liquid-liquid extraction of whole blood samples contaminated with 8 standards in known concentration. The whole blood samples were extracted at different pH values and analyzed by HPLC -PDA. Through the areas obtained from each standard, it was calculated the standardized factor matrix which showed a coefficient of variation less than 10 %. In order to compare two screening techniques for detection of drugs of abuse, post-mortem blood samples from the IC (n = 35) were also analyzed by immunochromatography, yielding 10 samples positive for amphetamine, 3 for benzoylecgonine and 1 for Δ9THC. The ATS by HPLC – PDA analyses showed only 1 sample positive for benzoylecgonine, 2 samples for amphetamines, and 3 benzodiazepines. In the other samples, no substance toxicological interest was detected. Both immunochromatography as systematic toxicological analysis proved useful tools in screening post-mortem blood. / As análises toxicológicas em diversas amostras são de extrema importância e podem ter várias finalidades, como por exemplo, o monitoramento de dependentes químicos, análises forense, controle de doping, monitoramento terapêutico, análise de contaminantes ambientais dentre outras. O objetivo deste trabalho foi analisar amostras de sangue post-mortem do Instituto de Criminalística de Goiás (IC) através de imunocromatografia e análise toxicológica sistemática por HPLC-PDA para a verificação da presença ou ausência de agentes tóxicos. As condições cromatográficas do método foram: fase móvel tampão fosfato de potássio monobásico pH 2,3 e acetonitrila, fluxo de 1 mL/min, coluna Lichrospher RP8, 5μm, 250 x 4,0mm, faixa de varredura de 200 a 380 nm. Os padrões de calibração utilizados foram MPPH, cafeína, benzeno e histamina. A base de dados utilizada foi a UVTOX proposta por Pragst e colaboradores (2001). Na validação parcial foi avaliado o efeito matriz através da extração líquido-líquido de amostras de sangue total contaminada com padrões de hidroclorotiazida, furosemida, flunitrazepam, flurazepam, amitriptilina, clordiazepóxido, nitrazepam e diazepam, na concentração de de 10 g/mL. As amostras de sangue total foram extraídas em diferentes valores de pH e analisadas por HPLC-PDA. Através das áreas obtidas de cada padrão, calculou-se o fator de matriz normalizado que apresentou coeficiente de variação inferior a 10%. Com o intuito de comparar duas técnicas de triagem para detecção de drogas de abuso, amostras de sangue post-mortem do IC (n=35) foram analisadas também por imunocromatografia, obtendo-se 10 amostras positivas para anfetamina, 3 para benzoilecgonina e 1 para Δ9THC. Por outro lado, na ATS por HPLC-PDA apenas 1 amostra foi positiva para benzoilecgonina, 2 anfetaminas, e outras 3 para benzodiazepínicos. Nas demais amostras não foi detectada nenhuma substância de interesse toxicológico. Tanto a imunocromatografia quanto a análise toxicológica sistemática se mostraram ferramentas úteis na triagem de sangue post-mortem.
|
2 |
Avaliação da presença de cocaína e anfetamina em amostras de sangue post mortem e de indivíduos vivos, utilizando técnica de microextração em fase líquida (HF-LPME) / Amphetamine, cocaine and tetrahydrocannabinol evaluation in blood samples of living people and post mortem blood samples using microextraction technique in liquid phase (HF-LPME).Sanchez, Clovis 18 April 2018 (has links)
Estima-se atualmente que mais de 5% da população mundial vem fazendo uso recreativo de algum tipo de substância psicoativa, sendo que o direito a esse uso é tema recorrente da sociedade contemporânea. Por apresentar riscos associados à saúde e a segurança das populações, o uso abusivo dessas substâncias tem instigado a toxicologia social na busca de respostas, com as quais se possa caracterizar, analisar e gerenciar esses riscos. Drogas de grande consumo no Brasil são a anfetamina, cocaína e Cannabis sativa. Esta tese desenvolveu uma nova metodologia para detectar e quantificar anfetamina, cocaína e tetrahidrocanabinol em sangue total, com uso de microextração em fase líquida via fibra de polipropileno (HF-LPME), seguida de cromatografia gasosa acoplada a espectrometria de massa (GC-MS). Trata-se de uma técnica que apresenta vantagens sobre as tradicionais, uma vez que demanda quantidades menores de solvente orgânico, diminuindo riscos e custos de processo. Também propôs um estudo com a aplicação dos métodos em 69 amostras de sangue de vivos e de post mortem, as quais foram obtidas por convênio com a superintendência da polícia técnica científica de São Paulo (SPTC/SP). Os métodos desenvolvidos foram validados de acordo com diretrizes internacionais de interesse forense. Como resultado da validação, os métodos desenvolvidos se mostraram precisos e exatos para anfetamina e cocaína. O limite de detecção da cocaína foi de 5 ng . mL-1 e o limite de quantificação de 10 ng . mL-1. Quanto a anfetamina, os limites de detecção e de quantificação foram de 5 ng . mL-1. A técnica de HF-LPME não foi aplicável ao tetraidrocanabinol (Δ9-THC). Como resultado da análise das amostras, 40% delas apresentaram resultados positivos para cocaína. Desses positivos, 35% foram oriundos das matrizes de sangue de vivos e 64% oriundos de sangue post mortem. Nenhuma delas apresentou resultado quantificável para anfetamina. / It is currently estimated that more than 5% of the world\'s population has been doing recreational use of some kind of psychoactive substances and the legal right to such use is a recurring theme debated by contemporary society. Due to the risks associated with populations health and safety, the abusive use of these substances has been instigating by social toxicology to search for answers to characterize, analyze and manage these risks. Drugs of great consumption in Brazil are, amphetamine cocaine and marijuana. This thesis proposes to develop a new methodology to detect and quantify psychoactive drugs in whole blood with the use of liquid phase microextraction by polypropylene fiber (HFLPME), followed by gas chromatography coupled to mass spectrometry (GC-MS). It is a technique that presents advantages compared with traditional ones, because of the smaller amounts demands of organic solvent, reducing risks and process costs. It also proposes a study with 69 blood samples taken from living persons and post mortem blood samples, which were obtained by agreement with the Superintendency of São Paulo Scientific Technical Police (SPTC / SP). The methods developed were validated according to international guidelines of forensic interest. As a result of the validation, the methods developed were precise and accurate for amphetamine and cocaine. The limit of cocaine detection was 5 ng . mL-1 and the limit of quantification was 10 ng . mL-1. As for amphetamine, the limits of detection and quantification were 5 ng . mL-1. The HF-LPME technique was not applicable to tetrahydrocannabinol (Δ9-THC). As a result of the sample analysis, 40% of them presented positive results for cocaine. Of these, 35% were from blood samples taken from living persons and 64% from the post mortem blood samples. None of the samples presented quantifiable results for amphetamine.
|
3 |
Avaliação da presença de cocaína e anfetamina em amostras de sangue post mortem e de indivíduos vivos, utilizando técnica de microextração em fase líquida (HF-LPME) / Amphetamine, cocaine and tetrahydrocannabinol evaluation in blood samples of living people and post mortem blood samples using microextraction technique in liquid phase (HF-LPME).Clovis Sanchez 18 April 2018 (has links)
Estima-se atualmente que mais de 5% da população mundial vem fazendo uso recreativo de algum tipo de substância psicoativa, sendo que o direito a esse uso é tema recorrente da sociedade contemporânea. Por apresentar riscos associados à saúde e a segurança das populações, o uso abusivo dessas substâncias tem instigado a toxicologia social na busca de respostas, com as quais se possa caracterizar, analisar e gerenciar esses riscos. Drogas de grande consumo no Brasil são a anfetamina, cocaína e Cannabis sativa. Esta tese desenvolveu uma nova metodologia para detectar e quantificar anfetamina, cocaína e tetrahidrocanabinol em sangue total, com uso de microextração em fase líquida via fibra de polipropileno (HF-LPME), seguida de cromatografia gasosa acoplada a espectrometria de massa (GC-MS). Trata-se de uma técnica que apresenta vantagens sobre as tradicionais, uma vez que demanda quantidades menores de solvente orgânico, diminuindo riscos e custos de processo. Também propôs um estudo com a aplicação dos métodos em 69 amostras de sangue de vivos e de post mortem, as quais foram obtidas por convênio com a superintendência da polícia técnica científica de São Paulo (SPTC/SP). Os métodos desenvolvidos foram validados de acordo com diretrizes internacionais de interesse forense. Como resultado da validação, os métodos desenvolvidos se mostraram precisos e exatos para anfetamina e cocaína. O limite de detecção da cocaína foi de 5 ng . mL-1 e o limite de quantificação de 10 ng . mL-1. Quanto a anfetamina, os limites de detecção e de quantificação foram de 5 ng . mL-1. A técnica de HF-LPME não foi aplicável ao tetraidrocanabinol (Δ9-THC). Como resultado da análise das amostras, 40% delas apresentaram resultados positivos para cocaína. Desses positivos, 35% foram oriundos das matrizes de sangue de vivos e 64% oriundos de sangue post mortem. Nenhuma delas apresentou resultado quantificável para anfetamina. / It is currently estimated that more than 5% of the world\'s population has been doing recreational use of some kind of psychoactive substances and the legal right to such use is a recurring theme debated by contemporary society. Due to the risks associated with populations health and safety, the abusive use of these substances has been instigating by social toxicology to search for answers to characterize, analyze and manage these risks. Drugs of great consumption in Brazil are, amphetamine cocaine and marijuana. This thesis proposes to develop a new methodology to detect and quantify psychoactive drugs in whole blood with the use of liquid phase microextraction by polypropylene fiber (HFLPME), followed by gas chromatography coupled to mass spectrometry (GC-MS). It is a technique that presents advantages compared with traditional ones, because of the smaller amounts demands of organic solvent, reducing risks and process costs. It also proposes a study with 69 blood samples taken from living persons and post mortem blood samples, which were obtained by agreement with the Superintendency of São Paulo Scientific Technical Police (SPTC / SP). The methods developed were validated according to international guidelines of forensic interest. As a result of the validation, the methods developed were precise and accurate for amphetamine and cocaine. The limit of cocaine detection was 5 ng . mL-1 and the limit of quantification was 10 ng . mL-1. As for amphetamine, the limits of detection and quantification were 5 ng . mL-1. The HF-LPME technique was not applicable to tetrahydrocannabinol (Δ9-THC). As a result of the sample analysis, 40% of them presented positive results for cocaine. Of these, 35% were from blood samples taken from living persons and 64% from the post mortem blood samples. None of the samples presented quantifiable results for amphetamine.
|
4 |
Aufbau und Anwendung einer Methode zur Identifizierung und Quantifizierung von Giften und deren Metaboliten in Blut und Haaren in der Systematischen Toxikologischen Analyse mittels Flüssigchromatographie-Quadrupol-Flugzeitmassenspektrometrie-Kopplung (LC-QTOF-MS)Broecker, Sebastian 15 February 2012 (has links)
Die Systematische Toxikologische Analyse (STA) stellt auf Grund der großen Vielfalt und der ständigen Zunahme an toxikologisch relevanten Substanzen eine der größten Herausforderungen in der chemischen Analyse dar. In der vorliegenden Arbeit wurde daher die Eignung der Flüssigchromatographie in Kombination mit der Hybrid-Quadrupol-Flugzeitmassenspektrometrie (LC-QTOF-MS) für diesen Zweck untersucht. Dazu wurden eine Datenbank mit über 7360 und eine CID-Spektrenbibliothek mit mehr als 2720 toxikologisch relevanten Substanzen erstellt und geeignete Probenvorbereitungsmethoden entwickelt. Die Erprobung der Methoden erfolgte an dotierten Blut- und Haarproben. Hierbei zeigte sich, dass die Analyse im Auto-MS/MS-Modus (Messzyklen von MS- und MS/MS-Spektren) eine Identifizierung basischer Substanzen mittels CID-Spektren zwischen 0,5 und 2 ng/ml im Blut ermöglichte. Die Nachweisgrenzen der für 24 Wirkstoffe validierten Methode in Haaren lagen bei 3 bis 15 pg/mg. Die Eignung der LC-QTOF-MS zur STA von Haarproben wurde an 30 Drogentodesfällen und 60 Todesfällen mit bekannter chronischer Medikamenteneinnahme zu Lebzeiten sowie an 77 Blutproben nachgewiesen. Für die Suche nach Metaboliten wurde ein Metaboliten-Tool entwickelt. In der praktischen Anwendung auf Datenfiles von Blut- und Haarproben erwies sich das Tool als wertvolles Hilfsmittel zur Identifizierung unbekannter Peaks und zur Bestätigung von Suchergebnissen in der Datenbank. Zur automatischen Konzentrationsabschätzung identifizierter Substanzen wurde ein Tool „Estimate Concentration“ geschaffen. Die Überprüfung des Verfahrens an realen Blut- und Haarproben durch Vergleich mit HPLC-DAD- und GC-MS-Ergebnissen wies eine gute Übereinstimmung der Konzentrationen auf. Insgesamt zeigten die Untersuchungen, dass die LC-QTOF-MS zurzeit die am besten geeignete Methode für die STA darstellt. Auch bei einem erst später aufkommenden Verdacht kann eine gezielte Suche in dem bereits gemessenen Datenfile durchgeführt werden. / Due to the large variety and the steady increase of toxicologically relevant substances, systematic toxicological analysis (STA) is one of the most difficult tasks in analytical chemistry and, therefore, a steady topic of research and methodical improvement. For this reason, the suitability of liquid chromatography in combination with hybrid quadrupole time-of-flight mass spectrometry (LC-QTOF-MS) for STA was investigated. For this purpose, a database of more than 7360 and a CID spectra library of more than 2720 toxicologically relevant substances and suitable methods for sample preparation were developed. The application was evaluated at spiked blood and hair samples. It was found that the analysis in Auto-MS/MS mode (alternating measurement cycles of MS and MS/MS spectra) allowed substance identification in blood using CID spectra between 0.5 and 2 ng/ml for basic substances. The detection limits of the validated method in hair ranged from 3 to 15 pg/mg for 24 drugs. The suitability of LC-QTOF-MS for STA was tested for hair samples from 30 drug-related death cases and from 60 death cases with known chronic medication as well as for 77 blood samples. For the search of metabolites, a metabolite tool was developed. In the practical application to data files from blood and hair samples, the tool proved to be very helpful for identification of unknown peaks and for confirmation of results obtained only from the database without CID spectra. A tool "Estimate Concentration" was created for automatic estimation of concentrations of identified substances. The application to real blood and hair samples and the comparison of the concentrations with results from HPLC-DAD and GC-MS showed good agreement. Overall, these investigations showed that LC-QTOF-MS is currently the most favorable method for STA. Because of the comprehensive registration of all substances in a sample, the data files can be checked for the presence of certain poisons even later without new measurements.
|
Page generated in 0.4259 seconds