• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 124
  • 2
  • 2
  • 1
  • Tagged with
  • 129
  • 95
  • 89
  • 70
  • 68
  • 49
  • 35
  • 31
  • 26
  • 22
  • 20
  • 19
  • 19
  • 19
  • 18
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Influência do hidróxido de cálcio na penetração do cimento Epiphany TM nos túbulos dentinários e na adaptação às paredes do canal radicular: avaliação pela microscopia confocal de varredura a laser / Influence of calcium hydroxide dressing on Epiphany TM sealer depth of dentinal tubules and interface dentine-sealer: a confocal study

Camargo, Éricson Janolio de 25 May 2009 (has links)
Avaliou-se a influência do curativo intra-canal com pasta de hidróxido de cálcio na penetração do cimento EpiphanyTM no interior dos túbulos dentinários e na adaptação do cimento às paredes dos canais radiculares utilizando-se a microscopia confocal de varredura a laser (MCVL). Foram utilizados 30 incisivos centrais inferiores humanos, extraídos, com apenas um canal radicular. O acesso ao canal foi realizado de forma convencional utilizando-se pontas diamantadas montadas em alta rotação, sob refrigeração. Os canais foram preparados pela técnica progressiva empregando-se instrumentos manuais e rotatórios de níquel-titânio, Protaper e Profile (conicidade 0.4). A irrigação foi realizada usando solução de hipoclorito de sódio a 1% e, ao final do preparo, o soro fisiológico. Após o preparo, os canais radiculares de todos os dentes receberam aplicação de EDTA a 17% por 3 minutos e irrigação final com soro fisiológico. A seguir, os dentes foram divididos em 3 grupos como segue: grupo 1 sem tratamento adicional (controle); grupo 2 curativo de Ca (OH)2 e grupo 3 - curativo de Ca (OH)2 e nova aplicação de EDTA. O curativo de Ca (OH)2 foi empregado na forma de pasta viscosa com propilenoglicol que foi inserida no canal com espiral de Lentulo. Após o curativo, os dentes foram armazenados a ± 37 °C por 14 dias. A remoção do curativo foi feita com irrigação com soro fisiológico e com instrumento manual. A seguir, os canais radiculares de todos os 30 espécimes foram obturados com o Sistema EpiphanyTM utilizando-se o primer, o cimento EpiphanyTM, cones principais de Resilon 40/0.4 e cones auxiliares fino-médio pela técnica da condensação lateral ativa. Antes da obturação, o cimento foi corado com Rodamina B. Foram feitas secções transversais a 3, 7 e 10 milímetros distantes do forame apical (terços apical, médio e cervical), cujas imagens foram analisadas em microscopia confocal por varredura a laser (MCVL). Os resultados foram submetidos aos testes estatísticos de Análise de Variância (ANOVA) e teste Tukey, ambos com 5% de significância. Os resultados indicaram que a maior penetração de cimento no interior dos túbulos dentinários foi verificada nas secções dos terços cervical e médio do grupo II comparado aos grupos I e III. A penetração do cimento em todas as secções foi maior e estatisticamente significante nas faces vestibular e lingual. Em relação à adaptação do cimento às paredes dos canais radiculares, a fluorescência do cimento, considerando o perímetro total do canal mostrou regiões com falhas na interface dentina-cimento. A menor porcentagem de adaptação foi observada no grupo I (78%) comparado com os grupos II (93%) e III (86%) (p<0,05). Em canais obturados com o Sistema EpiphanyTM pela técnica da condensação lateral, o hidróxido de cálcio influenciou positivamente na profundidade de penetração do cimento no interior dos túbulos dentinários e na sua adaptação às paredes dos canais. / The aim of this study was to evaluate the influence of calcium hydroxide on the depth of dentinal tubule sealer penetration and the percentage of sealer-dentin interface in the coronal, middle and apical thirds teeth obturated with the EpiphanyTM Obturation System using 5 x and 40x confocal laser scanning microscopy. Thirty extracted single-rooted mandibular incisor human teeth were instrumented using 1.0 % NaOCl. The smear layer was removed using 17% EDTA for 3 minutes. The teeth were randomly assigned to 3 groups (n=10), according to the presence or absence of intracanal dressing and its removal: GI= non Ca(OH)2 dressing (control); G II= Ca(OH)2 + removal using saline solution and kfile # 40; and G3= Ca(OH)2 + removal using saline solution + kfile # 40 and 17% EDTA. One tooth from groups II and III were ramdomly selected for calcium hydroxide analysis. The calcium hidroxyde was labeled with fluorescent fluorescein and after 14 days of storage in 100% humidity at 37 degrees C, the dressings were removed from experimental groups. All root canals (control and experimental groups) were obturated with Resilon master points 40/0.4, Resilon points fine-medium and EpiphanyTM sealer labeled with fluorescent Rhodamine B dye. The sections cut from the coronal, middle and apical thirds of each root were viewed using 5x and 40x confocal laser scanning microscopy. Twoway ANOVA and Tukey test found significantly lower average depth of sealer penetration in apical sections than middle or coronal sections (p<0,05). The deepest sealer penetration was observed in the coronal and middle secctions of group II compared to the groups I and III. The sealer penetration in all sections was deeper and statistically different in the vestibular and lingual faces. A fluorescent sealer ring was seen around the canal wall in all sections presenting some gaps in the sealerdentin interface. Two-way ANOVA and Tukey tests showed significantly less percentage of sealer-dentin interface in the group I (78%) compared to groups II (93%) and III (86%) (p<0,05). Calcium hydroxide dressing affected positively the deep of sealer penetration and percentagem of sealer dentin interface in the root canals filled with EpiphanyTM resin based sealer.
112

Avaliação da remoção de debris dentinários após diferentes métodos de irrigação final e sua influência na obturação do sistema de canais radiculares, utilizando a microtomografia computadorizada / Hard-tissue debris removal after different final irrigation methods and its influence on the filling of the root canal system, using micro-computed tomography

Freire, Laila Gonzales 03 June 2014 (has links)
A instrumentação do canal radicular possui como conseqüência a formação de debris dentinários, os quais acumulam-se especialmente nas áreas mais complexas do sistema de canais radiculares. Por este motivo, atenção especial tem sido concedida aos métodos de agitação da substâ ncia química auxiliar, com o intuito de melhorar a sua eficácia química e mecânica. No entanto, não está claro se debris dentinários removidos do interior do canal radicular possuem efeito na qualidade da obturação. Portanto, os objetivos deste estudo foram, com o auxílio da microtomografia computadorizada (micro-CT): avaliar e quantificar a presença de debris dentinários em canais curvos, após o preparo químico-cirúrgico; comparar a remoção desses debris, após uso de Irrigação Ultrassônica Passiva (IUP) ou do sistema EndoVac; e avaliar a qualidade da obturação dos mesmos canais, mensurando o volume de material obturador e de espaços vazios. Vinte e quatro raízes mesiais de molares inferiores humanos extraídos foram divididos aleatoriamente em 2 grupos (n=12), de acordo com o método de irrigação final a ser avaliado. Cada espécime foi submetido a quatro escaneamentos: exame préoperatório, exame pós-preparo, exame pós-irrigação final e exame pós-obturação, com um microtomógrafo de raios-X SkyScan 1176, a uma resolução de 17,42 m. Após preparo químico-cirúrgico os grupos receberam irrigação final com IUP ou com o sistema EndoVac e em seguida obturados com a técnica termoplástica de ondas contínuas de condensação. Após a reconstrução das imagens resultantes dos quatro escaneamentos, o corregistro das mesmas foi realizado com o programa DataViewer. Os programas CTAn e CTvol foram utilizados para binarização dos objetos de interesse, análise volumétrica e reconstrução de modelos 3D do canal radicular, dos debris dentinários e do material obturador. Os dados foram analisados estatisticamente com o programa GraphPad Prism por meio do teste t de Student (p < 0,05). As análises de micro-CT revelaram debris dentinários acumulados no interior dos canais radiculares, ocupando uma porcentagem média em relação ao volume do canal de 2,71% para o grupo IUP e 4,10% para o grupo EndoVac. Não houve diferença entre os grupos quanto à remoção de debris dentinários, nem em relação ao volume de material obturador e de espaços vazios (p > 0,05). Concluiu-se que a IUP e o sistema EndoVac foram igualmente eficientes na remoção de debris dentinários, reduzindo em média 50% do seu volume. Também, a ativação dos irrigantes pelos dois métodos não interferiu na qualidade da obturação do canal radicular. / Root canal preparation has as a consequence the formation of hard-tissue debris, which accumulates specially in the complex areas of the root canal system. For this reason, special attention has been given to methods of agitation of the irrigants, aiming to improve its chemical and mechanical efficiency. However, it is not clear if dentin debris removed from the root canal have impact on the quality of root canal filling. Therefore, the objectives of this study were, with the aid of microcomputed tomography (micro-CT): evaluate and quantify the presence of hard-tissue debris in curved root canals, after chemical-surgical preparation; compare the removal of such debris after final irrigation with Passive Ultrasonic Irrigation (PUI) or with the EndoVac system; and evaluate the quality of filling of the same root canals, measuring the volume of filling material and voids. Twenty-four mesial roots of extracted mandibular human molars were randomly divided into 2 groups (n = 12) according to the method of final irrigation being evaluated. Each specimen was subjected to four scans: preoperative, post-operative, post-final irrigation and post-filling, with a microcomputed tomography SkyScan 1176, at a resolution of 17,42 m. After chemosurgical preparation groups received final irrigation with Passive Ultrasonic Irrigation (PUI) or with EndoVac system and were then filled with the continuous wave condensation thermoplastic technique. After the reconstruction of the images resulted from the four scans, co-registration was performed with the DataViewer software. CTAn and CTvol softwares were used for binarization of the objects of interest, volumetric analysis and reconstruction of 3D models of the root canal, hardtissue debris and the filling material. Data were statistically analyzed with the GraphPad Prism program through t students test (p < 0,05). The analysis of micro- CT showed hard-tissue debris accumulated inside the root canal, occupying an average percentage of 2.71 % for the PUI group and 4.10 % for EndoVac group. There was no difference between the groups regarding the removal of hard-tissue debris, or in relation to the volume of filling material and voids (p > 0.05). It was concluded that the EndoVac and PUI were equally efficient in the removal of hardtissue debris, reducing an average of 50% of its volume. Also, irrigants activation with the two methods did not affect the quality of root canal filling.
113

Ausência de correlação entre a penetração do cimento AH Plus nos túbulos dentinários e a qualidade do selamento / Lack of correlation between AH Plus sealer penetration into dentinal tubules and sealability

Maria Cláudia Brandão de Souza 30 March 2010 (has links)
O presente estudo objetivou testar experimentalmente a existência da possível correlação entre a penetração de cimento nos túbulos dentinários e a qualidade do selamento. Foram utilizados 60 incisivos centrais superiores humanos que formaram um único grupo experimental. Após a eliminação das porções coronárias, as raízes foram padronizadas em 13 mm de comprimento. A instrumentação dos canais foi realizada no sentido coroa-ápice, e o comprimento de trabalho estabelecido a 1 mm aquém do forame apical. Como solução irrigadora foi empregado o NaOCl a 5,25% e ao final, EDTA a 17%. Em seguida, todos os canais foram obturados com guta-percha e cimento AH Plus marcado com um corante fluorescente. Para determinar a qualidade do selamento das obturações endodônticas, as amostras foram submetidas ao modelo de infiltração de glicose sob pressão. As raízes foram montadas em um dispositivo de dupla-câmara selada para permitir a infiltração da glicose. Como controle negativo foram utilizados 4 dentes hígidos, e como controle positivo, 2 dentes instrumentados porém, não obturados. Foram utilizados 0,75 mL de solução de glicose a 1 mol/L na câmara superior e 0,75 mL de água deionizada na câmara inferior. Os dispositivos foram conectados a um sistema de distribuição de pressão desenvolvido com o objetivo de permitir a infiltração de 32 amostras em uma mesma etapa. A solução de glicose foi forçada apicalmente sob uma pressão de 15 psi durante 1 hora. Uma alíquota de 50 L foi coletada da câmara inferior para quantificar a glicose infiltrada. A concentração de glicose foi determinada através de um método enzimático com o auxílio do Kit Glucose HK e de um espectrofotômetro em um comprimento de onda de 340 nm. Na sequência, as amostras foram desacopladas dos corpos de prova, embutidas em resina epóxi e cortadas em 3 secções transversais. Uma sequência de preparação metalográfica padrão foi realizada para permitir a observação da penetração de cimento nos túbulos dentinários por meio de microscopia confocal e óptica. Os dados obtidos nos 2 experimentos foram cruzados pelo teste de correlação de Spearman, o qual revelou a inexistência de qualquer possibilidade de correlação (r = 0,12). Com base nesses resultados, o presente trabalho concluiu que, dentro das condições experimentais usadas, a quantidade de cimento presente dentro dos túbulos dentinários não teve relação com a qualidade do selamento produzido. / The purpose of the present study was to experimentally test the potential correlation between tubular dentin sealer penetration and sealability. Sixty human maxillary central incisors were selected in order to compose a single experimental group. After removing of crowns, the roots were standardized at 13 mm in length. A crown-down root canal instrumentation was performed 1mm short of the apical foramen (working length). How irrigating solution was used 5.25% NaOCl and final, 17% EDTA. Then, all root canals were filled with gutta percha and AH Plus sealer labeled with a fluorescent dye. To determine the sealability pattern, samples were submitted to glucose leakage model under pressure. Four intact teeth were used as negative control while further 2 instrumented but nonfilled teeth was used as positive control. The roots were mounted in a double-chamber apparatus where 0,75 mL of 1 mol/L glucose solution was placed into the superior chamber and 0,75 mL of deionized water was placed into the inferior chamber. The devices were connected to a pressure distribution system that was developed in order to allow testing 32 specimens at the same experimental stage. The glucose solution was forced apically under a pressure of 15 psi during 1 hour. A sample of 50 L was taken from the inferior chamber and the glucose concentration was measured following an enzymatic reaction using a Glucose HK Kit readed under spectrophotometry (wave-length of 340 nm). After that, the samples were removed from the apparatus, embedded in epoxy resin and cut into 3 sections. Standard metallographic preparation was performed prior the observation of the sealer penetration into dentinal tubules by confocal and optical microscopy. Data provided by the evaluations were submitted to Spearman correlation test which revealed a lack of correlation between the two variables (r = 0.12). Therefore, the present study concluded that there was no correlation between tubular sealer penetration and sealability in non-bonding conventional root-fillings.
114

Impacto da ativação sônica e ultrassônica do cimento obturador dos canais radiculares na adaptação e resistência de união à dentina / Impact of sonic and ultrasonic activation of root canal sealer in the adaptation and bond strength to dentin

Paúl Ernesto Baca Wiesse 07 April 2016 (has links)
O objetivo deste estudo foi avaliar a resistência de união, a penetração e a adaptação à dentina radicular de cimentos obturadores à base de resina epóxica e de silicato de cálcio com e sem ativação sônica e ultrassônica. Raízes de caninos superiores com 16 mm de comprimento foram submetidas a preparo biomecânico com instrumentos rotatórios de níquel titânio sob irrigação constante com NaOCl 2,5% e irrigação final com EDTA 17%. As raízes foram distribuídas em grupos de acordo com os cimentos obturadores: AH Plus e MTA Fillapex. Cada grupo foi subdividido em função da ativação do cimento obturador (n=13): sem ativação; ativação sônica por 30 segundos; ativação ultrassônica por 30 segundos. Em cada subgrupo, a manipulação dos cimentos obturadores foi realizada de acordo com as instruções dos fabricantes para 10 espécimes, para os 3 espécimes restantes, o cimento foi acrescido de Rodamina B 0,1% previamente à manipulação. A obturação foi realizada de acordo com o protocolo de cada subgrupo em relação ao cimento e ativação, utilizando-se a técnica de condensação lateral. Após três vezes os tempos de endurecimento dos cimentos, os espécimes foram seccionados obtendo-se 3 slices de 1,0 mm de espessura de cada terço radicular. Dois slices de cada terço foram submetidos ao teste de push-out e o padrão de falha foi determinado. O terceiro slice de cada terço radicular foi submetido à análise qualitativa da adaptação do cimento à dentina radicular e presença de vazios, por meio de microscopia confocal de varredura a laser. Nos espécimes em que o cimento foi acrescido de Rodamina B 0,1%, avaliou-se a penetração do cimento na dentina radicular por microscopia confocal de varredura a laser com fluorescência. Os dados foram analisados por testes estatísticos paramétricos e não-paramétricos. O cimento AH Plus (2,58±1,21) apresentou maior resistência de união comparado ao MTA Fillapex (1,45±0,71) (p<0,122). A ativação ultrassônica (2,64±1,44) propiciou maior resistência de união comparada aos grupos sem ativação (1,58±0,73) (p<0,0001) e com ativação sônica (1,83±0,85) (p<0,0001), não havendo diferença entre estes (p=0,3303). O terço cervical apresentou maior resistência de união (2,48±1,49) comparado ao médio (2,08±0,94) (p=0,0003) e apical (1,48±0,58) (p<0,001). Para o cimento MTA Fillapex houve predomínio de falhas adesivas mistas em todos os grupos, enquanto que para o cimento AH Plus houve predomínio de falhas adesivas mistas para os grupos sem ativação e ativação ultrassônica e falhas adesivas mistas e adesivas ao material obturador para o grupo de ativação sônica. A ativação ultrassônica promoveu, independente do cimento obturador, maior número, densidade e extensão de tags, com massa obturadora mais homogênea e adaptada às paredes do canal radicular. A ativação sônica, por sua vez, apresentou número, densidade e extensão de tags similares ao grupo sem ativação, no entanto a massa obturadora apresentou desadaptações e formação de bolhas. A ativação ultrassônica impactou na maior resistência de união, penetração, densidade e extensão de tags e melhor adaptação do cimento a dentina radicular, ao contrário da ativação sônica que não aumentou a resistência de união e penetração de tags e proporcionou maior desadaptação e inclusão de vazios na massa obturadora. / The aim of this study was to evaluate the bond strength, penetration and adaptation to the root dentin sealers based on epoxy resin and calcium silicate with and without sonic and ultrasonic activation. Maxillary canine roots with 16 mm length were submitted to biomechanical preparation with nickel titanium rotary files, under constant irrigation with 2.5% NaOCl and final irrigation with 17% EDTA. The roots were divided into groups according to the sealers: AH Plus and MTA Fillapex. Each group was subdivided based on sealer activation (n = 13): no activation; sonic activations (30 seconds); ultrasonic activation (30 seconds). In each subgroup, the sealer manipulation was performed according to the manufacturers instructions for 10 specimens, for the 3 remaining specimens, the Rhodamine B 0.1% was incorpored to the sealer prior to manipulation. The root canal filling was performed according to the protocol of each group relative to the sealer and activation, using the lateral condensation technique. After three times the sealer setting times, the specimens were sectioned and obtained 3 slices of 1.0 mm thickness of each root third. Two slices of each third were submitted to the push-out test and the failure pattern was determined. The third slice of each root third was submitted to qualitative analysis of sealer and root dentin adaptation and the presence of voids, by means of confocal laser scanning microscopy. In specimens in which Rhodamine B 0.1% was added in the sealer was evaluated the sealer penetration in root dentin by confocal laser scanning fluorescence. The data were analyzed using parametric and nonparametric statistical tests. The AH Plus (2.58 ± 1.21) showed higher bond strength compared to MTA Fillapex (1.45 ± 0.71) (p <0.122). The ultrasonic activation (2.64 ± 1.44) provided higher bond strength compared to no activation groups (1.58 ± 0.73) (p <0.0001) and sonic activation (1.83 ± 0.85) (p <0.0001), with no difference between them (p = 0.3303). The cervical third showed higher bond strength (2.48 ± 1.49) compared to the middle (2.08 ± 0.94) (p = 0.0003) and apical thirds (1.48 ± 0.58) (P < 0.001). For the MTA Fillapex there was a predominance of mixed adhesive failures in all groups, whereas for AH Plus there was a predominance of mixed adhesive failures for groups without activation and ultrasonic activation and mixed adhesive failures and adhesives to the filling material for the sonic activation group. Ultrasonic activation promoted, regardless of the sealer, the greater number, density and length tags with more homogenous and adapted root canal filling to the root canal walls. On the other hand, the sonic activation, presented number, density and length of tags similar to the group without activation, however the root canal filling showed mismatches and blistering. Ultrasonic activation impacted the highest bond strength, penetration, density and length tags and better adaptation of the sealer root dentin, unlike the sonic activation that not increased bond strength and penetration tags and provided greater mismatch and the inclusion of voids in the root canal filling.
115

Evaluation of physicochemical properties of a new epoxy resinbased root canal sealer / Avaliação das propriedades físico-químicas de um novo cimento obturador de canais radiculares à base de resina epóxica

Gislene Cristina Vertuan 10 July 2018 (has links)
Introduction: The aim of this study was to evaluate some of the physico-chemical properties of a new root canal sealer. Methodology: The sealers tested were Sealer Plus (MKLife, Porto Alegre, Rio Grande do Sul, Brazil), compared as AH Plus (Dentsply, DeTrey GmbH, Konstanz, Alemanha). For the radiopacity, flow, solubility and fabrication of test specimens relative to setting times the ANSI/ADA No. 57 (2000) and ISO 6876 (2012) specifications were followed. To measure the initial and final setting times the ASTM C266/2008 standard was used. pH was evaluated in the time intervals of 3, 24, 72 and 168 hours). Statistical tests were applied to the results obtained at a level of significance of 5%. Results: The results demonstrated that the Sealer Plus sealer showed a lower radiopacity value than AH Plus sealer (p<0.05), however, this was higher than the minimum value recommended by the specifications; that is 3 mm Al. Relative to flow, the value for Sealer Plus was 19.19 mm and for AH Plus, 19.81 mm (p>0.05). Sealer plus presented initial and final setting times of 138 min. and 210 min., respectively, while the values for AH Plus were 437 min. and 849 min., respectively, (p<0.05). Relative to solubility, Sealer Plus presented 0.21% and AH Plus, 0.27% (p>0.05). None of the sealers showed a significant increase in pH (p>0.05). Conclusion: Sealer Plus sealer presented physico-chemical properties in accordance with ANSI/ADA (2000) No.57 and ISO 6876 (2012) specifications. / Introdução: Este estudo objetivou avaliar algumas propriedades físico-químicas de um novo cimento obturador de canais radiculares. Metodologia: Para os testes de radiopacidade, escoamento, solubilidade e confecção dos corpos de prova para os tempos de presa foram seguidas as especificações nº57 da ANSI/ADA (2000) e ISO 6876 (2012). Para a medição dos tempos de presa, inicial e final, foi empregada a norma ASTM C266/2008. O pH foi avaliado nos períodos de 3, 24, 72 e 168 horas. Sobre os resultados foram aplicados testes estatísticos com nível de significância de 5%. Resultados: Os resultados demonstraram que o cimento Sealer Plus apresentou menor radiopacidade do que o cimento AH Plus (p<0.05), porém, superior ao mínimo recomendado pelas especificações, ou seja, de 3 mm de Al. Com relação ao escoamento, o do Sealer Plus foi 19,19 mm e do AH Plus 19,81 mm (p>0.05). O Sealer Plus apresentou tempos de presa inicial e final de 138 min. e 210 min., respectivamente, enquanto o AH Plus, 437 min. e 849 min., respectivamente, (p<0.05). Em relação à solubilidade, o Sealer Plus apresentou 0,21% e o AH Plus 0,27% (p>0.05). Nenhum dos cimentos apresentou aumento significativo do pH (p>0.05). Conclusão: O cimento Sealer Plus apresentou propriedades físico-químicas de acordo com as especificações nº 57 da ANSI/ADA (2000) e ISO 6876 (2012).
116

Análise de uma nova ponta ultrassônica para agitação do irrigante em preparos retrógrados / Assessment of a new ultrasonic tip for irrigant agitation in root-end cavity preparations

Valencia, Yahir Muñoz 13 March 2019 (has links)
O objetivo desde estudo foi avaliar a eficiência de remoção de smear layer e a influência da resistência de união de cimentos de silicato de cálcio de um novo inserto ultrassônico para agitação do irrigante em preparos retrógrados. Metodologia Foram selecionados 112 caninos unirradiculados, que foram formatados e obturados de forma convencional com a subsequente ressecção apical. Seguidamente, foram conformados 4 grupos de avaliação, ultra-som/solução salina; convencional/solução salina; ultra-som/EDTA17% e convencional/EDTA17%. Para analisar a remoção do smear layer, 72 espécimes foram divididos em 4 grupos (n=18), e retroprepararados utilizando uma ponta ultrassônica. Os espécimes foram clivados, obtendo-se dois segmentos iguais (mesial e distal). Os segmentos retrocavitários foram observados através da microscopia eletrônica de varredura (MEV), a partir de três regiões representativas a 250x, obtendo-se imagens correspondentes à pré-irrigação. Posteriormente, foram executados os protocolos de irrigação e novamente obtidas imagens representativas da pós-irrigação. Para o teste de push-out, 40 dentes alocados em 4 grupos (n=10) foram empregados, conforme os diferentes protocolos de irrigação previamente mencionados. Os espécimes foram retrobturados e a obtenção dos corpos-de-prova realizada a partir de um novo seccionamento apical de 2mm±0.1 de cada espécime. A resistência de união foi determinada por meio de uma máquina de ensaios mecânicos e o tipo de falha foi determinado por meio de MEV. Os dados foram comparados por meio dos testes de Kruskal-Wallis e Dunn para a remoção de smear layer e ANOVA e Tukey no teste de push-out. Resultados O grupo ultrassom/EDTA17% removeu significativamente uma maior quantidade do smear layer, observando-se uma maior porcentagem de túbulos dentinários abertos em comparação com os outros grupos (P < 0.05). Na resistência de união, o grupo ultrasom/ EDTA17% mostrou os maiores valores na resistência de união (6.42±0.69) seguido pelos grupos convencional/EDTA17%, ultra-som/solução salina e convencional/solução salina respectivamente (P < 0.05). O padrão de falha adesivo foi o mais predominante, enquanto que no grupo ultrassom/EDTA17% foi preponderantemente mista (8/10). Conclusões O novo inserto ultrassônico para ativação do irrigante promoveu uma maior remoção de smear layer além de favorecer maior resistência de união do material retrobturador às paredes dentinárias em preparos retrógrados, principalmente se associado ao EDTA17%. / To evaluate the smear layer removal capacity and its influence on the bond strength of a calcium silicate-based cement of a new ultrasonic tip for irrigant agitation in rootend cavity preparations. Methods: One hundred and twelve maxillary and mandibular canines were chemomechanically instrumented, root filled and the root apexes resected. Specimens were randomly distributed into 4 experimental groups: ultrasonic/saline solution; conventional/ saline solution; ultrasonic/EDTA 17% and conventional/EDTA solution 17%. The analysis of the smear layer removal employed seventy-four specimens divided into 4 groups (n=18), and the retrograde cavities were prepared using an ultrasonic tip. Next, the specimens were split longitudinally and obtained two halves (mesial and distal). Scanning electron microscopy (SEM) was used to examine and score the internal surfaces for dentinal tubule opening before and after to perform the irrigation protocols. Images were taken at three representative areas with a magnification of 250x. The push-out test employed forty specimens allocated in four groups (n=10), according to the different irrigation protocols previously described. The specimens were retrofilled, sectioned perpendicularly and obtained apical slices at 2mm±0.1 from the apex. Each disc/dentin/retrofilling material was placed in a testing machine for the bond strength measurement and the failure mode was observed by SEM. The smear layer removal data were analysed and compared using Kruskal-Wallis and Dunn. Push-out data were analysed using ANOVA and Tukey\'s test. Results The ultrasonic/EDTA 17% group removed the smear later more effectively, and showed the best tubule opening condition than the others three groups. (P < 0.05). Ultrasonic/EDTA 17% group demonstrated the highest mean bond strength values (6.42±0.69) compared with conventional/EDTA, ultrasonic/saline solution and conventional/saline solution, respectively (P < 0.05). Most failure modes were predominantly adhesive (55%), whereas in the ultrasonic/EDTA 17% group was mixed (80%). Conclusion The new ultrasonic tip for irrigant agitation showed higher percentage of smear layer removal and improved the push-out bond strength of the retrograde root filling to the root-end dentine surfaces, mainly when associated to EDTA 17%.
117

Efeitos do tratamento endodôntico de dentes não vitais realizado em sessão única e múltiplas sessões: uma meta-análise

Almeida, Dulce Oliveira January 2013 (has links)
Submitted by Maria Creuza Silva (mariakreuza@yahoo.com.br) on 2013-10-07T18:30:57Z No. of bitstreams: 1 Diss MP Dulce Almeida. 2013.pdf: 1267001 bytes, checksum: 0b69cc06714872b88f9c86e9c7fb78c6 (MD5) / Approved for entry into archive by Maria Creuza Silva(mariakreuza@yahoo.com.br) on 2013-10-07T18:31:10Z (GMT) No. of bitstreams: 1 Diss MP Dulce Almeida. 2013.pdf: 1267001 bytes, checksum: 0b69cc06714872b88f9c86e9c7fb78c6 (MD5) / Made available in DSpace on 2013-10-07T18:31:10Z (GMT). No. of bitstreams: 1 Diss MP Dulce Almeida. 2013.pdf: 1267001 bytes, checksum: 0b69cc06714872b88f9c86e9c7fb78c6 (MD5) Previous issue date: 2013 / Esse estudo avaliou os efeitos do tratamento endodôntico de dentes não vitais realizado em sessão única em comparação com o de múltiplas sessões. Utilizou-se de busca eletrônica nas bases de dados Web of Science e Medline de ensaios clínicos randomizados para o tratamento endodôntico de dentes não vitais, comparativos para ambas as técnicas, que foram selecionados a partir de critérios de rigor metodológico. As referências dos estudos de revisões sistemáticas e meta-análises sobre a temática também foram analisadas. Os efeitos estudados foram o reparo periapical de lesões detectáveis radiograficamente, o controle microbiano e a dor pós-obturação. Dezessete ensaios clínicos randomizados (ECR) foram incluídos. Essa meta-análise apontou que o tratamento em única sessão promoveu maior reparo periapical, contudo este não foi estatisticamente significante [RR=1.04, IC95% (0.97-1.12)]. O tratamento endodôntico em única sessão apontou 21% menor dor pós-obturação que o tratamento em múltiplas sessões e esta diferença foi significante [RR= 0.79, IC95% (0.66-0.94)]. Em relação ao controle microbiano, a frequência de amostras positivas antes da obturação foi maior no grupo tratado em única sessão, entretanto, a diferença não foi estatisticamente significante [RR=2.48, IC95% (0.67-1.97)]. O tratamento endodôntico em única sessão não apresentou diferença em termos de reparo periapical e controle microbiano e provocou menor dor pós-obturação em relação ao tratamento em múltiplas sessões. Nesse sentido, do ponto de vista da saúde pública, poderia ser sugerida a adoção do tratamento endodôntico em sessão única. Entretanto, diante das limitações metodológicas dos estudos e da importância deste protocolo para a ampliação do acesso e da resolutividade, recomenda-se a realização de mais estudos clínicos para melhor avaliação dessa tecnologia na saúde pública. / Salvador
118

Biocompatibilidade de um material a base de guta-percha autoadesiva (Bio-Gutta) / Biocompatibility of a self-adhesive gutta-percha material (Bio-Gutta)

Felipe Gonçalves Belladonna 04 February 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo desse trabalho foi avaliar a biocompatibilidade de um material a base de guta-percha autoadesiva (Bio-Gutta) em tecido subcutâneo de camundongos. A guta-percha convencional foi utilizada como referência para comparação. Para isso, foram utilizados 30 camundongos, os quais foram distribuídos aleatoriamente em dois grupos (Bio-Gutta e guta-percha convencional). Os materiais avaliados foram implantados na região dorsal dos camundongos. Após 7, 21 e 63 dias, os animais foram sacrificados e 5 amostras por grupo por tempo experimental foram obtidas. As amostras histológicas foram seccionadas em 5 m de espessura e coradas convencionalmente com hematoxilina e eosina. Um escore de I-IV foi utilizado para graduar a reação inflamatória. O teste U de Mann-Whitney com correção de Bonferroni foi utilizado para análise estatística (p < 0,05). Os resultados mostraram que, após 7 dias, a Bio-Gutta induziu uma reação tecidual de leve a moderada (II) e a guta-percha convencional apresentou uma resposta inflamatória de moderada a intensa (III). Após 21 dias, a Bio-Gutta induziu uma leve reação tecidual (I), enquanto que a guta-percha convencional ainda apresentava uma resposta inflamatória moderada (III). Uma reação tecidual de leve a ausente (I) foi observada na Bio-Gutta após 63 dias, ao passo que na guta-percha convencional observou-se uma resposta inflamatória de leve a moderada (II). Houve diferença significativa na mediana do grau de inflamação entre os grupos em cada tempo experimental (p = 0,005, aos 7 dias; p = 0,011, aos 21 dias; e p = 0,003, aos 63 dias). Concluiu-se então que a Bio-Gutta foi mais biocompatível que a guta-percha convencional em tecido subcutâneo de camundongos apresentando uma boa resposta tecidual. / The purpose of this study was to evaluate the biocompatibility of a self-adhesive gutta-percha material (Bio-Gutta) in connective tissue of mice. Conventional gutta-percha was used as reference for comparison. Thirty mice were used in this study and they were randomly assigned into two groups (Bio-Gutta and conventional gutta-percha). The tested materials were implanted in the dorsal region of mice. After 7, 21 and 63 days, animals were sacrificed and 5 samples per group per time-point were obtained. Histologic samples were sectioned in 5 m thickness and stained with conventional hematoxylin and eosin. A grade from I-IV was used to graduate the inflammatory reaction. Bonferroni-corrected Mann-Whitney U test was used for statistical analysis (p < 0,05). The results showed that after 7 days Bio-Gutta induced a slight to moderate tissue reaction (II) and conventional gutta-percha presented a moderate to intense inflammatory response (III). After 21 days, Bio-Gutta presented a slight tissue reaction (I), while conventional gutta-percha still showed a moderate inflammatory response (III). A slight to absent tissue reaction (I) was observed in Bio-Gutta after 63 days, whereas conventional gutta-percha showed a slight to moderate inflammatory response (II). There was a significant difference in the median degree of inflammation between the groups at each time-point (p = 0,005, at 7 days; p = 0,011, at 21 days; and p = 0,003, at 63 days). It was concluded that Bio-Gutta was more biocompatible than conventional gutta-percha in subcutaneous tissue of mice showing a good tissue response.
119

Avaliação do pH, da liberação de íons cálcio e da adesividade de cimentos endodônticos contendo hidróxido de cálcio ou à base de MTA

Bier, Carlos Alexandre Souza [UNESP] 18 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:59Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-18Bitstream added on 2014-06-13T20:27:55Z : No. of bitstreams: 1 bier_cas_dr_arafo.pdf: 458795 bytes, checksum: df3d3967d50d9e31912505515f745092 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse estudo foi a avaliação da liberação de íons cálcio, do pH e da adesividade de alguns cimentos utilizados em Endodontia: Sealapex (G1), Sealer 26 (G2), Acroseal (G3), Epiphany (G4), MTA Branco (G5), Endo CPM Sealer (G6). Após a espatulação, os materiais foram inseridos em tubos de polietileno medindo 1,5 mm de diâmetro interno e 1 cm de comprimento com ambas extremidades abertas e imersos em frascos de vidro contendo 10 mL de água ultra pura. Nos períodos de 2, 6, 12, 24 e 48 horas, 7, 14 e 28 dias foram realizadas as análises, sendo o tubo contendo o cimento transferidos para novo frasco a cada período. O pH e a liberação de íons cálcio foram avaliados, respectivamente por meio de pH metro e espectrofotometria de absorção atômica. Para a avaliação da adesividade dos cimentos endodônticos às paredes dentinárias, os canais radiculares de 28 dentes humanos uniradiculados foram dilatados com brocas de Gates Glidden número 1, 2 e 3 e brocas largo número 1, 3 e 5. As raízes foram cortadas em máquina de corte para confecção de discos de 2 mm de espessura. Durante o preparo e depois da secção os espécimes foram irrigados com solução de hipoclorito de sódio a 2,5% e com EDTA a 17 % para a remoção da smear layer. Após a divisão aleatória nos grupos experimentais, os espécimes foram secos e preenchidos com os cimentos endodônticos, sendo mantidos em estufa a 37oC e 95% de umidade relativa do ar por 48 hs. Em seguida, cada conjunto dentina/cimento endodôntico foi submetido ao teste push-out em uma máquina de ensaio mecânico e a tensão necessária para a remoção do cimento medida em Mega Pascal (MPa). Após a coleta dos dados estes foram submetidos à análise estatística de Análise Variância e teste Tukey, com nível de 5% de significância. Os maiores valores de pH foram obtidos pelos G6, seguido por G2 e G5 após 2 horas (P<0,05)... / The aim of this study was to evaluate in vitro the pH, calcium ion release and adhesiveness provide by 6 endodontic filling materials: Sealapex (G1), Sealer 26 (G2), Acroseal (G3), Epiphany (G4), White MTA (G5), Endo CPM Sealer (G6). After manipulation, the sealers (n=10) were placed in tubes with 10 mm-long and 1.5 mm in diameter and immediately immersed in a glass flask containing 10 ml of ultra pure water, which was hermetically sealed and stored at 37°C. At 2, 6, 12, 24 and 48 hr, and at 7, 14 and 28 days after mixing the tubes were moved to new flask with fresh solution and the water in which they were immersed was analyzed for pH with a pH meter and for released calcium by atomic absorption spectrophotometry. To evaluate the adhesiveness of the sealers to the root canal wall, 28 teeth were enlarged to size 5 Largo drill and cut in a cutting machine to create 2 mm thickness slices. During all this procedure the root canal was irrigated with sodium hypochlorite 2.5% and with EDTA 17% to remove the smear layer. The slices were randomly allocated to one of the groups, dried and filled with the sealers and kept in a controlled environment (37oC and 95% humidity) to allow the setting of the sealers. After that, the slice root/endodontic sealer was submitted to push out test in a mechanical testing machine and the results were expressed in Mega Pascal (MPa). The results obtained at each time were statistically evaluated. After 2 hours the uppermost pH was found in the G6, followed by G2 and G5 (P<0,05). From 6 h till 24 h the highest value were observed in groups G5, G6 and G2. After 48 hours, the pH of groups G5 and G6 were stood out. Finally from the 7th to 28th days of evaluation G2, G5 and G6 presented the utmost pH. With regards to calcium ions release in beginning periods the G6 was statistical significantly from the other groups until the 7th day (P<0.05)... (Complete abstract click electronic access below)
120

Análise histomorfológica de dentes decíduos de cães com rizogênese incompleta, após biopulpectomia e obturação dos canais radiculares com hidróxido de cálcio em diferentes veículos

Murata, Sueli Satomi [UNESP] 10 February 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-02-10Bitstream added on 2014-06-13T20:44:33Z : No. of bitstreams: 1 murata_ss_dr_araca.pdf: 3025122 bytes, checksum: d6ebabe611a7dce5412ed2e2cf0535db (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A dentição decídua é passível de ser acometida por traumatismos, lesões cariosas precoces (cárie de mamadeira) ou outro tipo de injúria, que podem comprometer a vitalidade pulpar desses dentes, inclusive com rizogênese incompleta. A escassez de trabalho específico sobre o assunto, bem como a importância de solucionar adequadamente esse tipo de problema, em dentes decíduos com rizogênese incompleta, estimulam a realização de investigações sobre o assunto. Portanto, o objetivo deste estudo foi avaliar, histologicamente, a resposta dos tecidos apicais e periapicais de dentes decíduos de cães, com rizogênese incompleta, após biopulpectomia e obturação dos canais radiculares com hidróxido de cálcio em diferentes veículos. Assim, os canais radiculares de 80 dentes decíduos anteriores de 6 cães da mesma ninhada, com 50 dias de idade, e com rizogênese incompleta, foram empregados neste estudo. Após o preparo biomecânico, os canais radiculares foram obturados com os seguintes materiais: Grupo 1- pasta Vitapex (hidróxido de cálcio, iodofórmio e óleo de silicone), Grupo 2- hidróxido de cálcio acrescido de iodofórmio e soro fisiológico, Grupo 3- hidróxido de cálcio associado ao Lipiodol e, Grupo 4 - controle - dentes com canais preparados e não obturados. Trinta dias após o tratamento, os animais foram mortos e os espécimes preparados para análise histomorfológica. A análise estatística dos resultados permitiu que os materiais estudados fossem ordenados do melhor para o pior resultado da seguinte forma: a) hidróxido de cálcio acrescido de iodofórmio e soro fisiológico, b) pasta Vitapex (hidróxido de cálcio acrescido de iodofórmio e óleo de silicone), c) hidróxido de cálcio associado ao lipiodol, d) controle. / The deciduous teeth with open apex are susceptible to be traumatized by carious lesions or other offence type that can engage the pulp vitality of those teeth. The lacking of specific work on the subject, as well as the importance of solving this kind of problem appropriately stimulates the accomplishment of investigations on the subject. Therefore, the subject of this study was to evaluate, histologically, the behavior of apical tissues of deciduous dogs teeth with open apex, after biopulpectomy and root canal filling with calcium hydroxide in different vehicles. The root canals of 80 deciduous teeth, from 6 dogs of the same hatch, with 50 days of age, and with open apex, were used in this study. After the biomechanical preparation, the root canals were filled with the following materials: Vitapex - calcium hydroxide added to iodoform and silicon oil; paste of calcium hydroxide with iodoform and saline; paste of calcium hydroxide with lipiodol, and as control group, teeth with root canal prepared but not filled. Thirty days after the treatment, the animals were killed and the specimens were prepared for histomorphological analysis. The statistical analysis of the results allowed the studied materials to be ordered from the best to the worst in the following way: a) calcium hydroxide added to iodoform and saline, b) Vitapex - calcium hydroxide added to iodoform and silicon oil, c) calcium hydroxide added to Lipiodol, d) control. It was observed statistical significant difference (p=0.05) among the results of the groups of calcium hydroxide associated to iodoform and saline with the calcium hydroxide group associated to lipiodol, as well as the 3 groups filled with calcium hydroxide pastes with the control group (p=0.001). It was concluded that the 3 pastes of calcium hydroxide studied can be used as root canal filling material in the treatment of deciduous teeth with open apex.

Page generated in 0.0375 seconds