• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 371
  • 37
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 1
  • Tagged with
  • 414
  • 191
  • 113
  • 103
  • 81
  • 67
  • 59
  • 56
  • 50
  • 49
  • 45
  • 45
  • 40
  • 39
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Análise rugosimétrica de duas cerâmicas odontológicas submetidas a diferentes tratamentos de superfície

Ticianeli, Márcio Giampá [UNESP] 27 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-27Bitstream added on 2014-06-13T20:58:46Z : No. of bitstreams: 1 ticianeli_mg_me_arafo.pdf: 1350387 bytes, checksum: ea0f36454c6c9f5c29da9a1476668be1 (MD5) / Este estudo avaliou a eficiência de diferentes técnicas de acabamento e polimento sobre duas cerâmicas odontológicas (Duceram Plus e Duceram LFC), em relação à rugosidade média superficial (Ra). Foram preparados quarenta discos com 8 mm de diâmetro e 4 mm de espessura para cada uma das cerâmicas utilizadas, seguindo-se as recomendações do fabricante. Previamente ao glazeamento, todos os corpos-de-prova foram regularizados com o auxílio de lixas d'água de diferentes granulações (240,360 e 600, nesta ordem), recebendo, em seguida, uma camada de glaze. Os 40 corpos-de-prova de cada cerâmica foram divididos em 8 grupos com 5 representantes em cada um, recebendo diferentes tratamentos de superfície: T1- glaze; T2- desgaste com ponta diamantada fina e ultrafina; T3- T2 + sistema de acabamento e polimento dental Sof-Lex (3 M); T4- T3 + pasta diamantada; T5- T2 + kit de polimento Super-Snap (Shofu); T6- T5 + pasta diamantada; T7- T2 mais borrachas abrasivas Viking (KG Sorensen); T8- T7 + pasta diamantada. Foram realizadas cinco mensurações de rugosidade média (Ra, em æm) em cada corpo-de-prova, utilizando-se um rugosímetro ajustado com cut-off de 0,25 mm, extensão de tracejamento de 1,25 mm e velocidade de medição de 0,10 mm/s. Os resultados foram analisados estatisticamente pelos testes ANOVA e Tukey, com nível de significância de 5%. Os melhores tratamentos para ambas as cerâmicas avaliadas foram T3, T4, T5 e T6, apresentando semelhança estatística entre si; O glazeamento (T1) foi similar estatisticamente aos tratamentos T3, T4, T5 e T6 para a cerâmica Duceram LFC, em relação ao fator Ra; O tratamento T1 apresentou-se com diferença estatisticamente significante e mais rugoso que o tratamento T3, T4 e T6 para a cerâmica Duceram Plus, em relação ao fator Ra; As duas cerâmicas odontológicas avaliadas apresentaram... / This study assessed the efficacy of different current porcelain finishing and polishing procedures on two different dental ceramic (Duceram Plus and Duceram LFC) quantitatively with a profilometer. Forty disks (8 mm in diameter and 4 mm thick) were prepared for each dental ceramic according to the manufacturer's directions. Prior to glazing, all specimens' surfaces were abraded using a 240, 360 and 600-grit wet sandpaper. Then, all samples were glazed. The forty samples of each dental ceramic were divided into 8 groups of five specimens each, according to the surface treatment: T1- glaze; T2- abraded with fine and ultra fine diamond burs (KG Sorensen); T3- T2 following Sof-Lex (3M) polishing system; T4- T3 following diamond paste; T5- T2 following Super-Snap polishing kit (Shofu); T6- T5 following diamond paste; T7- Viking rubber wheels (KG Sorensen); T8- T7 following diamond paste. Five roughness measurements (Ra, æm) were performed on each disc using a profilometer with cut-off value of 0.25 mm and a tracing length of 1.25 mm and a speed of 0.1 mm per second. These values were tested using a two-way analysis of variance and Tukey test at 5% significance level. The result showed (to Ra factor) that T3, T4, T5 and T6 were the best surface treatment for both dental ceramic materials and were statistically equals; the glazed treatment (T1) was similar statistically to the polishing treatment T3, T4, T5 and T6 for Duceram LFC ceramic; the glazed treatment (T1) was different statistically and rougher than the polishing treatment T3, T4 e T6 for Duceram Plus ceramic; the two different dental ceramic had similar behavior when received the same surface treatment; and the diamond-abraded group (T2) had the rougher surface in both dental ceramic studied.
102

Influência do método de processamento na resistência à flexão, tração diametral e dureza dos sistemas cerâmicos

Oliva, Eduardo Andrade de [UNESP] 27 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-27Bitstream added on 2014-06-13T20:37:52Z : No. of bitstreams: 1 oliva_ea_me_arafo.pdf: 736376 bytes, checksum: 9f17d42680a151e51a9530e89dcbeb9a (MD5) / O objetivo deste trabalho foi avaliar a resistência à flexão, a resistência à tração diametral e a dureza das cerâmicas feldspáticas AllCeram (processada por sinterização) e Cergogold (processada por injeção à vácuo) e Ceramco 2 (processada por sinterização convencional e por injeção). Foram confeccionadas dez amostras de cada grupo experimental para o ensaio de resistência à flexão (em forma de barra, 25mm de comprimento, 5mm de largura, 2mm de espessura - ISO 6872) e 15 amostras para o ensaio de resistência à tração diametral (em forma de disco, 6mm de diâmetro, 3mm de espessura). Os testes foram realizados em equipamento MTS 810 (Material Test System, EUA), com célula de carga de 10kN e velocidade de 0,5mm/minuto, gerenciado por programa Test Star II (IBM, EUA). Para o ensaio de dureza, na escala Vickers, cinco fragmentos de cada grupo foram incluídos em resina acrílica autopolimerizável, polidos e submetidos ao teste no durômetro Buheler (EUA), com carga de 1,0kgf por 30 segundos. Dento da técnica de processamento indicada pelo fabricante, nos ensaios de resistência à flexão e dureza, os resultados apontaram igualdade estatística entre os materiais Ceramco 2 (73,75MPa / 478,8VNH) e Cergogold (68,96MPa / 495,3VHN); a seguir, com valores estatisticamente inferiores está a cerâmica All-Ceram (50,51MPa / 451VHN). No ensaio de resistência à tração diametral, houve igualdade estatística entre os 3 materiais: Ceramco 2 (34,15MPa), Cergogold (33,95MPa) e AllCeram (29,74MPa). Para a cerâmica Ceramco 2, o método de processamento sinterização ou injeção à vácuo não interferiu na resistência mecânica, apresentando valores com igualdade estatística para as três propriedades estudadas: respectivamente, resistência à flexão (73,75MPA, 77,88MPa), resistência à tração diametral (34,15MPa, 33,52MPa) e dureza... / The aim of this study was to compare flexural strength, diametral tensile strength and hardness of ceramics AllCeram (convencional fusing), Cergogold (heat-pressed) and Ceramco 2 (convencional fusing and heat-pressed). Ten especimens were made for flexural test (25mm length; 5mm width; 2mm thick - ISO 6872), and 15 especimens for diametral test (6mm diameter, 3mm thick). The tests were done in a MTS 810 machine (Material Test System - USA), with load cell of 10kN and crosshead-speed of 0.5mm/minute, managed by Test Star II software (IBM, USA). Five samples of each ceramic were included in autocured resin JET (Artigos odontológicos Clássico, Brazil), polished and submitted to Vickers hardness test in duromer Buheler (USA), with load of 1.0kgf for 30 seconds. Manuffacturer' processing technique the mean flexural stengths and hardness was significantly similar for Ceramco 2(73,75MPa / 478,8VNH) and Cergogold (68,96MPa / 495,3VNH), and significantly stronger than AllCeram (50,51 / 451VNH). All materials did not differ for diametral tensile (AllCeram 29,74MPa; Cergogold, 33,95MPa; Ceramco 2, 34,15MPa). Effects of processing method (convencional fusing and heat-pressed) did not influenced on flexural strength (73,75MPa / 77,88MPa), diametral tensile strength (34.15 MPa / 33,52 MPa) and hardness (478,8VHN / 471,5VHN) of Ceramco 2. However, for Ceramco 2 (heat-pressed) flexural strength (77,88MPa) became significantly higher and hardness (471,5VHN) became significantly lower than Cergogold (68,96MPa, 495,3VHN).
103

Influência do volume do preparo oclusal para inlays e do material restaurador na distribuição de tensão e resistência à fratura de pré-molares

Costa, Anna Karina Figueiredo [UNESP] 03 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-03Bitstream added on 2014-06-13T20:58:48Z : No. of bitstreams: 1 costa_akf_me_sjc.pdf: 897835 bytes, checksum: cf9331e50e009cd377dd79a71c87c93e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O estudo avaliou a influência da dimensão do istmo oclusal do preparo em inlays na distribuição de tensões e resistência à fratura de pré-molares superiores humanos restaurados com diferentes tipos de materiais. Foram selecionados 49 dentes hígidos e separados em 7 grupos (n=7) de acordo com o volume do preparo: conservador ou extenso e material restaurador: cerâmica ou resina, tendo como controle os grupos I (Integro - controle positivo), PC (Preparo Conservador) e PE (Preparo Extenso), ambos controles negativos. Os demais grupos foram separados de acordo com o tipo de mateiral da Restauração: RCR- inlay Conservador + Resina indireta Signum Ceramis (Heraeus); RCC-inlay Conservador + Cerâmica e.max Press; RER-inlay Extensa + Resina composta Signum Ceramis e REC -inlay Extensa + Cerâmica e.max Press. Os dentes preparados foram moldados e os modelos confeccionados e enviados ao laboratório para a confecção das inlays. Todas as restaurações foram cimentadas com cimento resinoso, e armazenadas em ambiente úmido por 24 h. Os corpos de prova foram submetidos ao ensaio de resistência à fratura em máquina de ensaio universal a uma velocidade de 0,5 mm/min, por meio de uma ponta aplicadora de 10 mm de diâmetro que possuia contatos exclusivamente nas vertentes triturantes das cúspides vestibular e lingual. Todos os fraguimentos foram analisados com estereomicroscópio para o mapeamento das fraturas. Os dados obtidos foram submetidos ao teste ANOVA e Tukey em um nível de significância de 5% . Para a análise da distribuição de tensão e deslocamento um pré-molar birradicular foi modelado com dimensões médias da literatura e analisados por elementos finitos. No ensaio in vitro, o grupo I (161,73±22.94) apresentou valores médios de resistência à compressão, seguido... / The porpose of this study was to evaluate the influence of the size of the occlusal isthmus preparation of inlays, stress and displatimant distribution on fracture toughness of upper human premolars restored by two different materials. They were selected 49 intact teeth and separated into seven groups (n = 7). In accordance to the volume of Preparation: Extensive and Conservative, or Restorative material: Ceramic or Resin, with the control groups I (positive control), PC and PE (negative control). The other groups were divided into: RCR-conservative inlay + indirect resin Signum Ceramis (Heraeus), RCC- conservative inlay + e.max Press ceramic; RER-extensive inlay + indirect resin Signum Ceramis and REC- extensive inlay + e.max Press ceramic. The teeth were prepared by special controled device and the model cast was sent to the laboratory for the preparation of inlays. The restorations were cemented with resin cement. All groups were subjected to a resistance to fracture test in a universal testing machine at a cross speed of 0.5 mm / min, by the tip of 10 mm in diameter, only contact teeth . The slices was evaluated by stereomicroscopy and made the mapping of fractures. It was used the statistical analysis of variance and Tukey's test. For the analysis of stress distribuition and displacment of cuspal teeth, one upper premolar was modeled with average dimensions of the literature and analyzed by finite emement method. In the in vitro assay, the group I (161.73±22.94) showed mean values of compressive strength, followed by REC (103.55±15.84), RCC (94.38±12.35), RCR (90.31±6.10), RER (65.42±10.15), PC (65.46±5.37), PE (58.08±9.62). The stress distribution was different in all groups studied, and the tooth with extensive preparation showed higher concentration of tensile stress on the cervical region of the proximal... (Complete abstract click electronic access below)
104

Efeito do preenchimento e do material restaurador na resistência à fratura e distribuição de tensões de pré-molares superiores fragilizados

Souza, Ana Carolina de Oliveira [UNESP] 12 December 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-12-12Bitstream added on 2014-06-13T20:18:35Z : No. of bitstreams: 1 souza_aco_me_sjc.pdf: 759377 bytes, checksum: 225aa1acb665faca70c699cec41a6b74 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste trabalho foi avaliar a influência do tipo de preenchimento e material restaurador na distribuição de tensões e resistência à fratura de pré-molares superiores tratados endodonticamente e com cúspides socavadas. Foram selecionados 40 pré-molares superiores humanos hígidos, sendo que 5 foram deixados intactos como controle (Grupo C+) e o restante realizado tratamento endodôntico e socavamento das cúspides. Cinco dentes foram separados para compor o controle negativo (Grupo C-), os demais foram divididos em dois grupos de acordo com o material de preenchimento (cimento de ionômero de vidro e resina composta) e realizados preparos para inlays. Foram então subdivididos em três grupos, sem restauração (PC: preenchimento com ionômero de vidro, PR: preenchimento com resina composta direta), restaurados com resina composta indireta (CS: preenchimento com cimento de iônomero de vidro e RS: preenchimento com resina composta direta) e os restaurados com cerâmica (CE: preenchimento com cimento de ionômero de vidro e RE: preenchimento com resina composta direta). As restaurações foram cimentadas com cimento resinoso dual e armazenadas em água destilada a 37 ºC por 24 h. Cada corpo de prova foi submetido a carga de compressão em máquina de ensaios universal, com velocidade de 1 mm/min. Os dados de resistência à fratura foram submetidos à análise de variância e ao teste de Tukey (5%). Os oito grupos formados foram modelados, importados pelo software Ansys 13.0, os volumes de cada geometria convertidos em elementos tetraédricos e submetidos á análise estática estrutural dentro do limite elástico e linear. Os resultados mostraram que a remoção de estrutura dentária afetou significantemente a resistência à fratura. Os menores valores foram... / The purpose of this study was to evaluate the influence of filling and restorative material on stress distribution and fracture resistance of premolars endodontically treated and weakened cuspal. Were selected 40 premolars healthy humans, 5 were left intact as controls (group C +) and others were performed endodontic treatment and removed the buccal and lingual dentin. Then 5 teeth were left to negative control (Group-C), the others were divided into two groups according to the filling material (glass ionomer and composite resin) and performed inlays prepares. They were then sudivided into three groups, no inlay restoration (PC: fill with glass ionomer, PR: fill with direct composite resin), restored with inlay made of indirect composite resin (CS: Fill glass ionomer (GIC) and RS: fill with resin composite) and restored with ceramic (EC: fill with VSD and RE: fill with resin composite). The restorations were cemented with dual cured resin cement and stored in distilled water at 37ºC/24h. Each specimen was compressed until the fracture in a universal testing machine with a 1mm/min of cross head speed. The eight groups were modeled, imported by software Ansys 13.0, the volume of each geometry were converted into tetrahedric elements and subjected to static structural analysis within the elastic limit and linear. Data fracture resistance were analysed by ANOVA and Tukey's test (5%). The results showed that removal of tooth structure affected significantly the fracture resistance values, the lowest were presented by the negative control group, followed by the groups restored and filled (no statistical difference between them) and all smaller than the control group positive. The different combinations of filling and restorative materials increased... (Complete abstract click electronic access below)
105

Relación entre el grado de satisfacción de los pacientes rehabilitados con prótesis total y la calidad de la prótesis, en el Centro Especializado en Formación Odontológica de la Universidad Católica Santo Toribio de Mogrovejo de Chiclayo, 2016

Flores Rivera, Gaby Fiorella, Nuñez Jimenez, Breigy Aranza January 2018 (has links)
El propósito de esta investigación fue evaluar la relación entre el grado de satisfacción de los pacientes rehabilitados con prótesis total y la calidad de la prótesis, en el Centro Especializado en Formación Odontológica de la Universidad Católica Santo Toribio de Mogrovejo de Chiclayo, 2016. El diseño del estudio fue de tipo analítico, observacional y transversal. La población de estudio fue de 52 pacientes que cumplieron con los criterios de inclusión y exclusión. Los instrumentos para la evaluación de las variables del estudio fueron: ficha de recolección de datos, cuestionario de Perfil de impacto de la salud oral en pacientes desdentados (OHIP-EDENT-Sp) y una ficha evaluativa de prótesis total. Los pacientes portadores de prótesis total mostraron estar satisfechos (88.5 %) y poco satisfechos (11.5%). También se evidenció que la calidad en las prótesis fue buena (13.5%), regular (76.9%) y mala (9.6%). La mayoría de pacientes satisfechos son los portadores de prótesis de regular calidad (69.2 %). Se concluyó que no existe relación entre la satisfacción y calidad de la prótesis mediante la prueba Chi-cuadrado (p-valor= 0.083). / Tesis
106

Rugosidade de superfície e resistência flexural do IPS Empress 2 submetida a seis tratamentos de superfície / Rafael Moura Jorge ; orientador, Danilo Biazetto de Menezes Caldas ; co-orientador, Janaína Bertoncelo de Almeida

Jorge, Rafael Moura January 2007 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2007 / Bibliografia: f. 18-20 / Objetivo: Avaliar a rugosidade média de superfície (Ra) e resistência flexural (Rf) de uma cerâmica reforçada por disilicato de lítio submetida a seis diferentes tratamentos. Materiais e Métodos: 150 espécimes da cerâmica IPS Empress 2 foram fabricados se / Objective: The aim of this study was to evaluate the surface roughness and flexural strength of a lithium disilicate reinforced ceramic submitted to six different treatments. Materials and methods: One hundred and fifty specimens of IPS Empress 2 were pre
107

Promoção da saúde bucal em bebês participantes de um programa educativo-preventivo na cidade de Ponta-Grossa-PR / Oral health promotion in infant participants of one program educative preventive in the city of Ponta Grossa-PR

Kuhn, Eunice January 2002 (has links)
Made available in DSpace on 2012-09-06T01:11:57Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 476.pdf: 1308429 bytes, checksum: 363f3401df04d9d6784b09f6cb611a06 (MD5) Previous issue date: 2002 / Avalia a influência de um programa educativo/preventivo na promoção da saúde bucal de 122 bebês, na faixa etária de 1 a 36 meses e suas respectivas mães, residentes na cidade de Ponta Grossa/PR. Através de questionários aplicados no início do estudo, e após 12 meses, identificou-se o conhecimento materno prévio e hábitos adotados com sua própria saúde bucal e a de seus filhos, bem como alterações ocorridas após transmissão de informações, para a instituição de hábitos saudáveis, desde os primeiros anos de vida. O grupo sob intervenção foi atendido de 3 em 3 meses, durante 15 meses. A cada consulta, as crianças tinham seus dentes higienizados, e suas mães acesso a orientações formativas, para práticas preventivas adequadas, além da possibilidade de incluí-las em suas pautas de vida. Ao final do estudo, foi examinado um segundo grupo com 106 crianças, na mesma faixa etária, não participantes do programa educativo/preventivo. A redução de hábitos inadequados e o menor percentual de lesões cariosas no grupo sob intervenção (9,83 por cento), em comparação com o grupo que não sofreu intervenção (38,68 por cento), sugere que: a) Apenas a informação ou conhecimento materno prévio sobre hábitos adequados, constatado através do questionário, não refletiu em atitudes saudáveis em relação à saúde bucal de seus filhos; b) O envolvimento materno com medidas educativas e preventivas, em programas de promoção da saúde bucal, podem determinar redução na prevalência da doença cárie em bebês; c) Ações educativas em programas de promoção da saúde bucal, aliadas ao reforço constante, desenvolveram habilidade e competência materna, estimulando o autocuidado em relação à saúde bucal de seus filhos; d) Integradas a um sistema de saúde de atenção básica, as ações educativas e preventivas resultam em medidas de impacto significativo, de baixa complexidade e baixo custo.
108

Influência do método de processamento, sinterização convencional ou injeção a vácuo, na resistência à flexão e dureza de porcelanas feldspáticas

Oliva, Eduardo Andrade de [UNESP] 09 March 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-03-09Bitstream added on 2014-06-13T21:06:55Z : No. of bitstreams: 1 oliva_ea_dr_arafo.pdf: 607307 bytes, checksum: 9f87d55685186049423938eda2ef54e0 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Universidade Estadual Paulista (UNESP) / O objetivo deste trabalho foi avaliar, por meio de ensaios de resistência à flexão, em três pontos, e de dureza, o comportamento mecânico das porcelanas feldspáticas Duceram Plus, Excelsior, Duceragold, Symbio, VMK, Omega 900 e Vitadur Alpha, submetidas a dois métodos de processamento laboratorial: sinterização convencional (fabricantes) e por injeção a vácuo (experimental). Foram confeccionadas dez amostras de cada grupo experimental para o ensaio de resistência à flexão (em forma de barra, 25mm de comprimento, 5mm de largura, 2mm de espessura - ISO 6872). Os testes foram realizados em equipamento MTS 810 (Material Test System, EUA), com célula de carga de 10kN e velocidade de 0,5mm/minuto, gerenciado por programa Test Star II (IBM, EUA). Para o ensaio de dureza, na escala Vickers, cinco fragmentos de cada grupo foram incluídos em resina acrílica autopolimerizável, polidos e submetidos ao teste em durômetro Buheler (EUA), com carga de 300gf, por 30 segundos. As cerâmicas Duceram Plus, Excelsior, Omega 900, Symbio e VMK 95 apresentaram maior resistência à flexão quando processadas por injeção. Os materiais Ducera Gold e Vitadur Alpha não sofreram qualquer influência deste método de processamento. O processo de injeção a vácuo, experimental, não alterou a dureza dos materiais estudados. / The aim of this study was to compare the flexural strength and hardness of seven feldspatic ceramics (Duceram Plus, Excelsior, Duceragold, Symbio, VMK, Omega 900 and Vitadur Alpha) processed by convencional fusing and heat-pressing. Ten especimens were made for flexural test (25mm length; 5mm width; 2mm thick - ISO 6872). The tests were realized in a MTS 810 machine (Material Test System - USA), with a 10kN load cell and crosshead-speed of 0.5mm/minute, managed by Test Star II software (IBM, USA). Five samples of each ceramic were included in autocured resin JET (Artigos odontológicos Clássico, Brazil), polished and submitted to Vickers hardness test in duromer Buheler (USA), with load of 300gf, for 30 seconds. Results showed that the ceramics Duceram Plus, Excelsior, Omega 900, Symbio and VMK 95 presented higher flexural stengths values when heat-pressed. Ducera Gold and Vitadur Alpha flexural stengths values werenþt affected by the processing method.
109

Efeito de diferentes taxas de resfriamento sobre a porcelana feldspática de cobertura para infraestrutura em zircônia

Almeida Junior, Antonio Alves de [UNESP] 25 April 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-04-25Bitstream added on 2014-06-13T20:06:12Z : No. of bitstreams: 1 almeidajunior_aa_dr_arafo.pdf: 984476 bytes, checksum: 5c77bf9dbe20dfc1beb4cc756485b9f9 (MD5) / A maior incidência de lascamentos na porcelana de cobertura é uma das principais desvantagens de restaurações com infraestrutura em zircônia se comparada com as metalocerâmicas. Essa maior ocorrência pode ser explicada por diferenças nas propriedades mecânicas das porcelanas indicadas para infraestrutura em zircônia ou por estresses residuais devido às propriedades térmicas dos materiais cerâmicos. Assim, este estudo apresentou os seguintes objetivos: 1. Comparar a resistência à flexão (MPa), confiabilidade pelo módulo de Weibull, dureza Vickers (VHN) e tenacidade à fratura (MPa/mm1/2) de duas porcelanas feldspáticas utilizadas sobre infraestrutura em zircônia (Vita VM9 e e.Max Ceram) e duas porcelanas feldspáticas utilizadas sobre infraestrutura metálica (Vita VMK95 e Duceragold); 2. Avaliar a resistência à fratura por flexão, confiabilidade, probabilidade de falha, dureza Vickers, tenacidade à fratura pelo método do entalhe em V e índice de cristalinidade por difratometria de raios-X de corpos-de-prova monocamada da porcelana Vita VM9 submetidos a três métodos de resfriamento; 3. Analisar a resistência à fratura por flexão, confiabilidade, resistência de cisalhamento da união e o modo de falha em corpos-de-prova bicamada de zircônia (ZrHP) e porcelana feldspática (Vita VM9) submetidos a diferentes taxas de resfriamento. No primeiro estudo, análises estatísticas de Kruskal Wallis e Dunn foram utilizadas(p<0,05). Não foi observada diferença estatística na resistência à flexão (p=0.31) entre as porcelanas. O módulo de Weibull apresentou maior confiabilidade para a porcelana VMK95 seguido por e.Max, Vita VM9 e Duceragold. No ensaio de dureza Vickers, as porcelanas e.Max, VM9 e VMK95 não apresentaram diferença estatística, enquanto a Duceragold apresentou o menor valor (p<0,001)... / The high incidence of chipping of the feldspathic porcelain veneer is one of the disadvantages of zirconia-based restorations in comparison to metal-based prosthesis. This highest occurrence may be explain by the difference in the mechanical proprieties of the porcelain to zirconia system or by the residual tensions due to thermal proprieties of ceramic materials. Then, the purpose of this study was: 1. To compare the three-point flexural strength (MPa), Weibull parameters, Vickers hardness (VHN) and Vickers indentation fracture toughness (MPa/mm1/2) of feldspathic porcelains for metal (Vita VMK95 and Duceragold) and for zirconia frameworks (Vita VM9 and e.Max Ceram); 2. To compare the flexural strength, reliability and probability of failure, measured by Weibull analysis, Vickers hardness, V-notch fracture toughness, and crystallinity index by Powder X-ray Diffractometry Technique of monolayer specimens of a dental feldspathic veneer porcelain for zirconia (VITA VM9) subjected to three different cooling conditions; 3. To investigate the effect of three cooling methods on the flexural strength, reliability, shear bond strength and failure mode of bilayer specimens of veneer porcelain (VITA VM9) and zirconia (ZrHP). In the first study, Kruskal-Wallis and Dun test were used for statistical analysis (p<0.05). There was no significant difference (p=0.31) among the porcelains in the flexural. Weibull calculation presented highest reliability for VMK95 followed by e.Max, VM9 and Duceragold. Vickers hardness test showed that e.Max, VM9 and VMK95 had no difference and Duceragold had the lowest value (p‹.001). The highest fracture toughness was to VMK95, while VM9 and e.Max had the lowest values (p‹.001). It was concluded that, despite of the suitable flexural strength, reliability... (Complete abstract click electronic access below)
110

Comportamento de fratura sob carga estática e cíclica das cerâmicas odontológicas quando unidas a um substrato análogo à dentina

Salazar Marocho, Suzana María [UNESP] 02 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-02Bitstream added on 2014-06-13T21:07:03Z : No. of bitstreams: 1 salazarmarocho_sm_dr_sjc.pdf: 1643366 bytes, checksum: 55a9fb193b1109c1d2a63470d40ce628 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os objetivos desse estudo foram: 1) determinar a porosidade (%) dos agentes cimentantes (Panavia F (PF), Variolink II low (VLL) e high viscosity (VLH) e Rely X U100 (RU)) quando interpostos entre dois substratos, material cerâmico e resina com módulo de elasticidade semelhante à dentina (NG10); 2) Determinar o comportamento de fratura de uma porcelana odontológica (VM7), de uma cerâmica policristalina de infra-estrutura (YZ), e da YZ recoberta por uma porcelana odontológica (VM9) quando unidas (complexo cerâmica-cimento-NG10) e não unidas adesivamente ao substrato de NG10 quando submetidas a carga de fratura estática; 3) Determinar o comportamento de fratura do complexo cerâmica-cimento- NG10 quando submetidos ao teste de fadiga cíclica após armazenagem em meio úmido; e 4) determinar o modo e origem da falha das estruturas fraturadas, após o teste estático e fadiga cíclica. Espécimes como: 1) Discos monolíticos de VM7 (n= 40), 2) VM7+agente cimentante (n= 20), 3) VM7+agente cimentante+NG10 (n=320), e 4) V9/YZ+agente cimentante+NG10 (n= 320) foram confeccionados e testados em compressão após 24 h, 1 mês, 3 e 6 meses de armazenagem em meio úmido. O grupo 3) foi avaliado sob efeito de fadiga cíclica, aplicando-se o 60% do valor da carga de fratura do teste estático. A porosidade (%) presente na camada de cada agente cimentante quando interposto no conjunto cerâmica-NG10 foi semelhante foi semelhante após aplicação da carga de fratura estática e cíclica. A união adesiva das estruturas cerâmicas ao substrato análogo à dentina influenciou no comportamento à fratura dos conjuntos formados pela porcelana V7. Os valores de carga de fratura estática foram superiores para a cerâmica YZ independente da união adesiva ao NG10. A porcelana de recobrimento da YZ se mostrou... / The aim of this research was 1) to investigate the porosity (%) of resin cements (RC) when adhesively bonded to a ceramic material and a dentin analog material (NG10); 2) determine the fracture load of a porcelain (VM7), a polycrystalline framework ceramic (YZ), and a YZ veneered with a porcelain (VM9) bonded to NG10; 3) determine the fatigue lifetime of the ceramic-RC-NG10 assemblies; and 4) determine the mode of failure and the initial defect size of ceramic structures after compression and fatigue testing. 1) VM7 monolithic disks (V7) (n=40), 2) VM7+RC (V7.RC) (n=20), 3) VM7+RC+NG10 (V7.RC.NG10) (n=320), and 4) VM9/YZ+RC+NG10 (V9/YZ.RC.NG10) (n=320) were built up, wet aged for 24 h, 1 month, 3 and 6 months, and tested under compression test. The compressive force required to cause fracturing was recorded in Newtons (N). The following RC were used: Panavia F (PF), Variolink II low (VLL) and high viscosity (VLHV) and Rely X U100 (RU). V7 groups were subjected to compressive fatigue loading. At both tests, the crosshead movement was stopped when the first discontinuity appeared in the recording chart, indicating early crack formation. The porosity (%) of the RC layer in each assembly was similar among all groups, except for the ones cemented with VLL. After the first 3 months, the characteristic fracture load of V7.RC.NG10 groups was similar, except for V7.VLL.NG10. The former group showed the best mechanical behavior. The fracture compressive values were higher for YZ than for V7, even independently of dentin bonding. All the YZ assemblies’ fractures occurred within the veneering layer during the fatigue test. There was a significant difference between the survival rates of the complexes during the fatigue test. The performance of YZ assemblies was superior to V7 in the compressive and fatigue test... (Complete abstract click electronic access below)

Page generated in 0.0426 seconds