• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 984
  • 34
  • 34
  • 34
  • 34
  • 29
  • 29
  • 18
  • 14
  • 14
  • 6
  • 4
  • 1
  • 1
  • Tagged with
  • 1004
  • 450
  • 288
  • 190
  • 188
  • 167
  • 158
  • 156
  • 150
  • 145
  • 127
  • 111
  • 106
  • 94
  • 93
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
431

Avaliação em modelo fotoelástico do sistema de força gerado pela mola T de retração

Maia, Luiz Guilherme Martins [UNESP] 10 July 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:53Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-07-10Bitstream added on 2014-06-13T20:36:29Z : No. of bitstreams: 1 maia_lgm_me_arafo.pdf: 792493 bytes, checksum: 55e953092d5be55cdff1f450dee78f37 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A fotoelasticidade é um fenômeno ótico muito utilizado em pesquisas da engenharia e da mecânica. Este método avalia áreas submetidas à forças provenientes de sistemas mecânicos complexos e transforma luz comum polarizadas em padrões de luz isoclínicas e isocromáticas denominados franjas fotoelásticas. A fotoelasticidade foi utilizada pela primeira vez em pesquisa odontológica por Zak, em 1935, quando ele aplicava forças ortodônticas de diferentes pontos de aplicação e observava o sistema de força gerado por esse sistema. Esse fenômeno pode ser observado através do polariscópio e os testes são realizados em modelos fotoelásticos construídos a partir da resina epóxi. Baseado nisso, esta pesquisa avaliou o sistema de força gerado pela mola T de retração ortodôntica para fechamento de espaço, confeccionada com fio de titânio-molibdênio de secção transversal 0,017X 0,025, com três tipos de pré-ativação, sendo a primeira definida por Burstone, a segunda por Marcotte e a terceira, por Souza. A distância interbráquete utilizada foi de 27,0mm e a mola T foi posicionada, centralizada no espaço interbráquete e a avaliação do sistema de força foi analisado tanto para o lado da retração quanto para o lado de ancoragem. Cada mola era ativada em posição neutra, ativação média e ativação máxima. Para o registro dos testes utilizou-se uma máquina digital e após a obtenção dos registros as imagens foram impressas, interpretadas qualitativamente e expressa em gráficos. O sistema de força desenvolvido entre as três pré-ativações mostrou-se com maior concentração de energia para a Mola T com pré-ativação de Souza, seguindo por marcotte e por último, Burstone. Concluiu-se o sistema de força liberado pela Mola T retração, apresentou um sistema de força simétrico entre o segmento de ancoragem e o segmento ativo. / Photo elasticity is an optical phenomenon used quite a lot in engineering and mechanical research. This method evaluates areas submitted to forces created by complex mechanical systems and transforms ordinary polarized light into patterns of isoclinic and isocromatic light known as photo elastic fringes. Photo elasticity was used for the first time in orthodontic research by Zak, in 1935, when he applied orthodontic forces from different application points and observed the force systems generated by this system. This phenomenon can be observed through the polariscope and the tests are carried out on photo elastic models made from epoxy resin. Based on this, this research evaluated the force system generated by a orthodontic T spring retractor for the closure of spaces, made with a titanium-molybdenum wire with a transversal section of 0,017 X 0,025, with three types of pre-activation, the first having been defined by Burnstone, the second by Marcotte and the third by Souza. The inter-bracket distance used was of 27, 0 mm. and the T spring was placed, centralized in the inter-bracket space and the evaluation of the force system was analyzed both at the retraction point and at the anchorage point. Each spring was activated in a neutral position, medium activation and maximum activation. A digital camera was used to register the tests and, after obtaining the records, the images were printed, qualitatively interpreted and expressed graphically. The force system developed among the three pre-activation types showed a greater energy concentration with the Souza pre-activation type, followed by the Marcotte type and lastly by the Burnstone type. It was concluded that the force system liberated by the T spring retractor presented a symmetrical force system between the anchorage segment and the active segment.
432

Influência de diferentes protocolos de fotoativação no grau de conversão e dureza de resinas ortodônticas

Amato, Patrícia Alves Ferreira [UNESP] 21 September 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-09-21Bitstream added on 2014-06-13T20:17:26Z : No. of bitstreams: 1 amato_paf_me_arafo.pdf: 1148687 bytes, checksum: e0775a47f9ed415815c6089651f02842 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A presente Dissertação foi composta de dois estudos. O primeiro estudo avaliou in vitro a influência de diferentes tempos de exposição e potências, mantendo-se a mesma energia total, no grau de conversão (GC) e dureza superficial Knoop de três resinas ortodônticas (Transbond XT, Opal Bond MV e Transbond Plus Color Change) fotoativadas por um LED de 3a geração. A análise do GC foi realizada pelo método de Espectroscopia de infravermelho por transformada de Fourier (FT-IR) em nove grupos (n=5) e a dureza superficial Knoop também foi avaliada em nove grupos (n=15), sendo todos os grupos divididos de acordo com as resinas, potências e tempos utilizados. O segundo estudo comparou o GC de duas resinas ortodônticas (Transbond XT e Opal Bond MV) fotoativadas por um LED de 2a geração e um de 3a geração dada uma mesma densidade de energia. A análise do GC foi realizada pelo método de Espectroscopia infravermelho por transformada de Fourier (FT-IR) em quatro grupos (n=5) divididos de acordo com as resinas e gerações de LED utilizados. Os valores obtidos nos dois estudos foram analisados pelo teste ANOVA de dois níveis. No primeiro estudo, as resinas apresentaram iguais graus de conversão quando fotoativadas pelos tempos T1(8,5s) e T2(6s) e menor grau de conversão em T3 (3s). A resina Transbond Plus Color Change apresentou maior grau de conversão, seguido pela Opal Bond MV cujo grau de conversão foi maior que o da Transbond XT. As resinas apresentaram menor dureza quando fotoativadas pelo tempo T1 (8,5s), mas não houve diferença entre os tempos T2 (6s) e T3 (3s). A resina Transbond Plus Color Change apresentou maior dureza superficial do que a Opal Bond MV, sendo ambos os grupos mais duros do que Transbond XT. Foi detectada interação entre as resinas e os tempos utilizados na dureza das resinas. No segundo... / The present dissertation consisted of two studies. The first study was aimed at assessing in vitro the influence of different exposure times and potencies, keeping the same total energy, on the degree of conversion and Knoop surface micro-hardness of three orthodontic resins (Transbond XT, Opal Bond MV, and Transbond Plus Colour Change) light-cured with a third-generation LED unit. The second study was aimed at comparing the degree of conversion of two orthodontic resins (Transbond XT and Opal Bond MV) light-cured by using 2nd and 3rd generation LED units operating at the same power density. In the first study, the degree of conversion was assessed by using the Fourier transform infrared spectroscopy (FT-IR) in nine groups (n = 15), whereas the Koop surface micro-hardness was assessed in nine groups, with groups being divided according to the resins, potency and exposure time. In the second study, the degree of conversion was also assessed by using FT-IF in four groups (n = 5) divided according to resins and LEDs used. The values obtained were analysed with two-tailed ANOVA. Resins light-cured at T1 (8.5s) and T2 (6s) showed the same values for degree of conversion, but a lower value at T3 (3s). The Transbond Plus Colour Change resin showed the highest degree of conversion, followed in the order by Opal Bond MV and Transbond XT ones. Resins showed a decreased micro-hardness when light-cured at T1 (8.5s), but no difference was found between T2 (6s) and T3 (3s). The Transbond Plus Colour Change resin showed a greater surface micro-hardness than the Opal Bond MV resin, with both groups being harder than the Transbond XT resin. A relationship between resins and exposure time was found regarding the micro-hardness of these materials. No difference was found between the degrees of conversion of the resins... (Complete abstract click electronic access below)
433

Avaliação do sistema de força e estabilidade a longo prazo gerado por molas T do grupo B

Caldas, Sergei Godeiro Fernandes Rabelo [UNESP] 20 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-20Bitstream added on 2014-06-13T18:56:42Z : No. of bitstreams: 1 caldas_sgfr_me_arafo.pdf: 855000 bytes, checksum: eaa6df403dc4e8613479a7fb3776a600 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Comparar o efeito do tipo de pré-ativação (curvatura ou dobra) e avaliar o efeito do alívio de tensão estrutural sobre a estabilidade do sistema de força gerado por molas “T” do grupo B confeccionadas com fio de beta-titânio 0,017” x 0,025” (TMA®, Ormco Corporation, Glendora, EUA). Materiais e Métodos: Dois artigos científicos foram redigidos e utilizados para a avaliação dos propósitos apresentados. Resultados: As molas “T” pré-ativadas por curvatura produziram forças horizontais significativamente menores (variando de 51 gf a 405 gf) do que as molas pré-ativadas por dobras (variando de 106 gf a 431 gf). Não foram encontradas diferenças em relação aos momentos produzidos durante a desativação em ambos os grupos. As proporções momento-força foram sistematicamente maiores nas molas “T” pré-ativadas por curvatura do que as molas pré-ativadas por dobras (de 5,7 mm a 41,1 mm versus 5,4 mm a 15,2 mm), exceto para 5 mm de ativação. Foram encontradas diferenças significativas nas relações carga-deflexão (grupo curvatura = 78,07 gf/mm e grupo dobra = 71,65 gf/mm) e na posição neutra (grupo curvatura = - 0,18 mm e grupo dobra = -0,99 mm). As forças horizontais foram maiores (P<0,001) para o grupo imediato (267,6 gf) comparado aos demais grupos (200,7 gf a 181,7 gf), os quais não foram diferentes entre si. A posição neutra foi maior no grupo imediato (-0,99 mm) do que nos demais grupos (P<0,001) e o tempo não teve influência sobre a relação carga-deflexão (P=0,129). Os momentos gerados na desativação foram geralmente maiores (P=0,001) no grupo imediato (1932,6 gf.mm) do que nos demais grupos (1696,6 gf.mm a 1471,3 gf.mm), os quais não foram diferentes entre si. Todos os grupos produziram proporção momento-força semelhantes (P=0,640). Conclusões: As molas “T” pré-ativadas por curvatura apresentaram forças horizontais menores... / Compare the effect of preactivation (curvature or concentrated bend) and evaluate the changes in force system caused by stress relaxation of group B T-loop springs made with .017” x .025” beta-titanium (TMA®, Ormco Corporation, Glendora, USA) wires. Materials and Methods: Two research papers were written and analyzed for the evaluation of the aims presented. Results: TLSs preactivated by curvature delivered horizontal forces significantly lower (ranging from 51 gf to 405 gf) than the TLS preactivated by concentrated bends (ranging from 106 gf to 431 gf). No differences were found in relation to the moments produced throughout the deactivation of both groups. The moment-to-force ratios were systematically higher on the TLSs preactivated by curvature than the TLS preactivated by concentrated bends (from 5.7 mm to 41.1 mm versus 5.4 mm to 15.2 mm), except on 5 mm of activation. Significant differences were found in the load-deflection rates (curvature group = 78.07 gf/mm and concentrated bends group = 71.65 gf/mm) and neutral position (curvature group = -0.18 mm and concentrated bends group = -0.99 mm). The horizontal forces were higher (P<.001) for immediate group (267.6 gf) compared to the other 8 groups (200.7 gf to 181 gf) which were not different among themselves. The neutral position was greater in immediate group (-0.99 mm) than on the other groups (P<.001), and time did not have an effect on the load-deflection ratio (P=.129). The moment levels produced throughout the deactivation were generally higher (P=.001) for immediate group than for the other groups (1696.6 gf.mm to 1471.3 gf.mm) which were not different among themselves. All groups produced similar moment-to-force ratios (P=.640). Conclusions: The TLSs preactivated by curvature delivers lower horizontal forces and higher MF and LD ratios than the TLS preactivated by concentrated bends... (Complete abstract click electronic access below)
434

Efeito da polimerização e desinfecção na resistência flexural e na topografia da superfície de resina acrílica

Oliveira, Derly Tescaro Narcizo de [UNESP] 15 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-07-15Bitstream added on 2014-06-13T18:56:44Z : No. of bitstreams: 1 oliveira_dtn_me_araca.pdf: 464380 bytes, checksum: 604c14584189497c81a25c41ad98c57e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A ação dos produtos desinfetantes sobre as propriedades físico-químicas da resina acrílica norteia sua seleção para a higienização de aparelhos ortodônticos removíveis. Avaliou-se a resistência à fratura de resina acrílica ativada quimicamente após ciclagem em diferentes soluções desinfetantes. Foram confeccionados quarenta corpos de prova com resina acrílica autopolimerizável incolor (Clássico,Ind.&Com.Ltda./Brasil) utilizando-se matriz metálica retangular e circular, seguindo-se às técnicas de polimerização sob pressão úmida (imersão em água/n=20) e sob pressão seca (sem água/n=20) foram subdivididos em 4 grupos (n=5), conforme a solução utilizada para ciclagem: água destilada (Controle), bicarbonato de sódio, hipoclorito de sódio 1% e Corega®Tabs. A ciclagem consistiu em imersão em 100 ml da solução por 10 minutos três vezes ao dia e, em seguida, manutenção em recipiente fechado contendo saliva artificial a 37ºC. Este ciclo foi realizado durante 30 dias, trocando-se as soluções e a saliva a cada procedimento executado. Na sequência os espécimes foram submetidos ao ensaio de resistência flexural a três pontos foi utilizada máquina EMIC DL3000, à velocidade de 5mm/min, dispondo-se as amostras em suporte contendo dois apoios de sustentação, sendo aplicada força axial e equidistante aos dois outro pontos até a ruptura do corpo-de-prova. Os espécimes circulares foram levados para leitura em Microscópio de Força Atômica (AFM - V Nanoscope Veeco). Os resultados, submetidos à análise de variância (P<0,001 ) e o Teste de Tuckey (P<0,05) não apontaram diferenças significantes para a resistência flexural. Conclui-se que os métodos de polimerização e as soluções testadas não modificaram a resistência flexural... / The disinfectant products action on the physicochemical properties of acrylic resin guides its selection to the cleaning of removable orthodontic appliances. The fracture resistance of acrylic resin after cycling in different disinfectant solutions was evaluated. Forty specimens were made with colorless acrylic resin (Clássico, Ind. & Com.Ltda. / Brazil), using matrix, followed by the techniques of polymerization under wet pressure (immersion in water / n = 20) and dry pressure (no water / n = 20). The samples were divided into 4 groups (n = 5) as the solution used for cycling: distilled water (Control), sodium bicarbonate, sodium hypochlorite 1% and Corega®Tabs. The cycling consisted of immersion in 100 ml of solution for 10 minutes three times a day and then maintained in a closed container containing artificial saliva at 37 º C. These cycles were conducted during 30 days, changing the solutions and artificial saliva for each procedure performed. Latter, the specimens were submitted to surface analysis with Atomic Force Microscope (AFM - Veeco Nanoscope V). A machine, EMIC DL3000, was used for the three-point flexural strength test, speed of 5mm/min, providing the sample in medium containing two restraints support. After that axial force was applied and equidistant to the two other points to the body to break the specimens. The results were submitted to analysis of variace(P<0,001) and Tuckey Test (P<0,05) showed no significant differences in flexural strength test. The Atomic Force Microscopy analysis revealed less topographical roughness for the group Corega®Tabs. We conclude that the polymerization methods and solutions tested did not alter the flexural strength of the material studied except the comparation between... (Complete abstract click electronic access below)
435

Apresentação de um método experimental de traumatismo dentoalveolar em ratos para realização de experimentos de movimentação dentária induzida

Pereira, Alex Luiz Pozzobon [UNESP] 21 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-21Bitstream added on 2014-06-13T19:36:12Z : No. of bitstreams: 1 pereira_alp_me_araca.pdf: 556236 bytes, checksum: 813123fc195762e6557fa1b6003a934b (MD5) / Universidade Estadual Paulista (UNESP) / Este trabalho tem como finalidade apresentar um método para estudo do traumatismo dentoalveolar, utilizando um dispositivo capaz de promover a mesma intensidade e sentido de aplicação da força sobre molares de ratos, e dessa forma, ser utilizado como um modelo de estudo experimental na movimentação dentária induzida de dentes previamente traumatizados. Para a realização desse traumatismo foi utilizado um tensiômetro, com uma das suas extremidades adaptada para exercer um impacto sobre o primeiro molar superior. O tensiômetro foi fixado em um suporte de metal com a finalidade de padronizar a direção da aplicação da força e posicionar corretamente sua extremidade sobre o primeiro molar superior. Aplicou-se um trauma no sentido ocluso-gengival de 600 gramas sobre a região oclusal do primeiro molar superior direito de 10 ratos, correspondente à aproximadamente 600cN. Em seguida os animais foram mortos e a maxila direita coletada para análise microscópica do tecido pulpar e o ligamento periodontal da raiz mesial do primeiro molar superior. A análise microscópica demonstrou que a força de 600cN não se mostrou efetiva para promover alterações no ligamento periodontal, polpa e raiz. Por outro lado, demonstrou que um trauma de intensidade menor como a concussão, não promove alterações no ligamento periodontal, e por sua vez não representa um problema para o ortodontista. / This study has as purpose to present a method for study of the dentoalveolar traumatism, using a device capable to promote a traumatism maintaining the same intensity and sense of application of the force on molars of rats, and in that way, to be used as a method of experimental study in the induced movement of teeth previously traumatized. For the accomplishment of that traumatism a gauge was used, with one of their extremities adapted to exercise an impact on the first superior molar. The gauge was fastened in a metal support with the purpose of to standardize the direction of the application of the force and to position his extremity correctly adapted on the first superior molar. A injury was applied in the ocluso-gingival sense on the vestibular crest of the first right superior molar of 10 rats with force of 600 grams, corresponding to the approximately 600cN. Soon afterwards the animals were died and the right maxillary bone collected for histological analysis of the pulpal and the periodontal ligament of the root mesial of the first superior molar. The histological analysis demonstrated that the force of 600cN was not shown executes to promote alterations in the periodontal ligament, pulp and root, on the other hand it demonstrated that a trauma of smaller intensity as the concussion, doesn't promote alterations in the periodontal ligament, and for his time it doesn't represent a problem for the orthodontist.
436

Análise comparativa da movimentação dentária induzida entre dois critérios de mensuração: macroscópico e microscópico

Moreira, José Roberto Alves [UNESP] 18 December 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-12-18Bitstream added on 2014-06-13T20:36:30Z : No. of bitstreams: 1 moreira_jra_me_araca.pdf: 1339735 bytes, checksum: cfd84571d16e3c5f07f98a1436fe8ecd (MD5) / Este estudo analisou a quantidade de deslocamento dentário por meio de mensurações macroscópicas e microscópicas, após a movimentação dentária induzida. Os dois Grupos Experimentais GI (forças contínuas) e GII (forças contínuas interrompidas) constituíram-se de 30 ratos, da linhagem Wistar, subdivididos de acordo com o período experimental de 8, 16 e 24 dias. Cada subgrupo foi composto por dez animais, assim como o Grupo Controle (GC), perfazendo um total de 70 animais. O aparelho destinado para se obter o deslocamento dentário foi o desenvolvido por Heller e Nanda. As molas de secção fechada foram instaladas no espaço entre os incisivos superiores e primeiro molar superior direito. Após ativações, de acordo com o tipo de força e tempo experimental, os animais foram mortos. Mediu-se a espessura do ligamento periodontal por meio de microscopia histomorfométrica quantitativa na raiz vestibular intermediária do primeiro molar superior direito do rato, na região distal (tração) e macroscópica, no espaço resultante entre os primeiro e segundo molares superiores direitos. A metodologia empregada permite concluir que as mensurações microscópicas são mais precisas e seguras para determinar o deslocamento na movimentação dentária induzida. / This study analyzed the amount of displacement, by measuring macroscopic and microscopic, after induced tooth movement. Both groups GI (continuous forces) and GII (interrupted continuous force) comprised of 30 rats, Wistar, were subdivided according to the experimental period of 8, 16 and 24 days. Each group comprised of ten animals, as well as the control group (CG), totaling 70 animals. The appliance used to obtain the displacement, was developed by Heller and Nanda. The nickeltitanium (NiTi) coil springs were installed in the space between the upper incisors and the upper first right molar. After activation, according to the type of force and experimental time, animals were sacrificed. A quantitative histomorphometric microscopy was used to the measurement of the periodontal ligament thickness in the mesiobuccal root of the first upper right molar of the rat, in the distal and macroscopic region, at reached space between the first and second upper right molars. The microscopic measurements are accurate and reliable to determine the displacement in the induced tooth movement.
437

Estudos das caracteristicas cefalométricas do padrão face longa

Cardoso, Mauricio de Almeida [UNESP] 29 January 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-01-29Bitstream added on 2014-06-13T18:56:47Z : No. of bitstreams: 1 cardoso_ma_me_araca.pdf: 2774339 bytes, checksum: c873d63ba814e0623036d4e2c840794d (MD5) / Este estudo objetivou determinar as características cefalométricas dos indivíduos portadores de Padrão Face Longa em comparação com indivíduos Padrão I e verificar a presença de dimorfismo entre gêneros nesse tipo de displasia esquelética. Um total de 73 telerradiografias em norma lateral, sendo 34 Padrão Face Longa e 39 Padrão I, foram selecionadas com base na morfologia facial, não considerando as relações oclusais e sagitais. Foram avaliados: padrão de crescimento facial, alturas faciais anteriores e posterior, relação maxilo-mandibular, além das relações dentárias com suas bases apicais. De uma forma geral, os indivíduos Padrão Face Longa apresentaram grandes desvios em relação aos indivíduos Padrão I, sendo a doença decorrente de um desequilíbrio entre os componentes verticais Pôde-se observar que os valores das grandezas AFAT, AFAI, AFATperp, AFAIperp, 1-PP, 6-PP, 1-PM, SNB, ANB, ângulo goníaco, ângulo plano mandibular, além das proporções AFAI/AFAT e AFAIperp/AFATperp, estavam significantemente alterados para os indivíduos Padrão Face Longa. Com base nos resultados obtidos neste estudo, verificou-se que esses indivíduos caracterizavam-se pelo padrão de crescimento vertical e por um aumento da altura facial anterior inferior - conseqüentemente, da altura facial anterior total - estando a deformidade localizada abaixo do plano palatino. Foram observados ainda um retrognatismo maxilar e mandibular, além da presença de extrusão dentária anterior e póstero-superior, com os incisivos superiores bem posicionados em suas bases e, os inferiores, lingualizados. O conjunto de alterações esqueléticas deu ao gênero feminino uma face longa mais marcadamente severa. / This study aimed to determine cephalometric characteristics of long face pattern patients in comparison to Class I pattern patients and to verify the presence or not of sexual dimorphism in this kind of skeletal dysplasia. A total of 73 lateral norm telerradiographs, 34 long face pattern and 39 Class I pattern individuals, were selected and compared with regards to facial morphology, not considering occlusal and sagital relationships. Additionally, evaluations were also made on facial growth pattern, anterior and posterior facial heights, maxillary-mandibular relationship, as well as apical bases relationship and dental characteristics. In short, long face pattern individuals presented a large number of deviations compared to Class I pattern individuals, dysplasia being due to a disproportion among vertical components. It was observed that the values of variables TAFH, LAFH, TAFHperp, LAFHperp, 1-PP, 6-PP, 1-MP, SNB, ANB, goniac angle, mandibular plane angle, and the proportions among the facial heights were significantly altered in long face pattern individuals. Based on the results obtained from the present study, it has been verified that those individuals were characterized by the vertical growth pattern and by an increase of anterior and inferior facial height, the deformity being located below the palatal plane. It was also possible to verify a maxillary and mandibular retrognathism, as well as the presence of anterior and posterosuperior dental extrusion, with apical incisors in apical base, and linguoclinated lower incisors. The entire skeletal alteration has given the feminine gender a more severely marked longer face.
438

Comparação quantitativa da retração de caninos superiores utilizando dois sistemas de ancoragem

Kina, Juliana [UNESP] 27 August 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-08-27Bitstream added on 2014-06-13T20:17:28Z : No. of bitstreams: 1 kina_j_me_araca.pdf: 1193550 bytes, checksum: d217ade36af8adc9e54b137cf2f19928 (MD5) / Introdução: Para a eficiência da ancoragem, diferentes protocolos são preconizados durante a mecânica ortodôntica, principalmente quando se deseja a retração inicial do canino para o alinhamento e nivelamento anterior sem a mesialização do segmento posterior. Nesse contexto, a utilização dos minimplantes tem sido cada vez mais frequente, pois possuem características desejáveis para essa finalidade como a facilidade operacional de sua instalação, dispensa a colaboração do paciente para o desenvolvimento da mecânica ortodôntica,é favorável na estética e permite um sistema de forças mais previsível. O objetivo deste trabalho foi comparar quantitativamente por meio de telerradiografias em norma lateral e radiografias panorâmicas, a taxa de retração inicial de caninos (RIC) superiores, utilizando-se dois sistemas distintos de ancoragem. Métodos: Foram selecionados 18 pacientes, formando dois grupos aleatórios de 9 indivíduos (G1 e G2), triados para tratamento ortodôntico na UNESP - Araçatuba. Como ancoragem foi utilizado minimplantes no grupo G1 e botão de Nance no grupo G2. Para todos os pacientes foram realizadas duas telerradiografias em norma lateral (T1 e T2) e duas panorâmicas (P1 e P2). Para comparação entre as fases Início (antes do tratamento) e Após (após a retração inicial de caninos) foi utilizado o teste t pareado. Para a comparação entre os grupos de minimplante e botão de Nance foi utilizado o teste t de Student para medidas independentes. Em todos os testes foi adotado nível de significância de 5% (p<0,05). Resultados: Para a RIC no Grupo G1, obteve-se uma média de 0,63 mm/mês, enquanto para o grupo G2 a média foi de 0,56 mm/mês. Conclusões: A análise das telerradiografias em norma lateral e das radiografias panorâmicas revelou a inexistência de diferença estatisticamente significante entre os dois grupos. / Introduction: For efficiency of the anchorage, different protocols are recommended during orthodontic mechanics, especially when clinicians want to retract the initial alignment and leveling without the inclination of the posterior segment. In this context, the use of mini-implants has been frequent. For this purpose it has desirable characteristics, such as the operational facility of installation, the collaboration of the patient, exemption for the development of orthodontic mechanics, it is favorable in appearance and allows more predictable system forces. This study compared, by teleradiographs and panoramic radiographs, the initial rate of retraction of canines (ICR), using two different systems of anchoring. Methods: 18 patients were selected and divided in two random groups of 9 subjects (G1 and G2). They needed and were refered to orthodontic treatment at UNESP - Araçatuba. In G1, mini-implants were used as anchor and G2 used the Nance button appliance. Two teleradiographs (T1 and T2) and two panoramic (P1 and P2) were made for all patients. The paired T test was used for comparison between Initial (before treatment) and After (after the initial retraction of canines) phases. Student's t test for independent measures was used for comparison between groups of mini-implants and the Nance button appliance. A significance level of 5% (p <0.05) was adopted in all tests. Results: For G1, an average of 0.63 mm / month was obtained, while for G2, the average was 0.56 mm / month. Conclusions: The analysis of teleradiographs and panoramic radiographs showed the absence of statistically significant difference between the two groups.
439

Avaliação do nível de conhecimento de um grupo de ortodontistas sobre o traumatismo dentoalveolar e a movimentação ortodôntica em dentes traumatizados

Tondelli, Pedro Marcelo [UNESP] 26 November 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:54Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-11-26Bitstream added on 2014-06-13T19:36:13Z : No. of bitstreams: 1 tondelli_pm_me_araca.pdf: 590546 bytes, checksum: aeb9176085968db3f0cc84416bac14dc (MD5) / O objetivo deste trabalho foi avaliar o nível de conhecimento de um grupo de ortodontistas, em regiões específicas do Brasil, sobre o traumatismo dentoalveolar e a movimentação ortodôntica em dentes traumatizados. Para este propósito, foram distribuídos 166 questionários com 25 perguntas objetivas sobre o assunto, dos quais 105 questionários foram devidamente preenchidos e recolhidos após 30 dias. Concluiu-se que, para 37% dos profissionais entrevistados, o nível de conhecimento para os traumatismos considerados não foi satisfatório, e quanto à movimentação ortodôntica, em dentes traumatizados, aproximadamente, 40% dos entrevistados não responderam satisfatoriamente as questões formuladas. / The objective of this work was to assess the knowledge level of an orthodontists’ group in specific areas of Brazil, about dental trauma and orthodontic movement in traumatized teeth. For this purpose, 166 questionnaires with 25 objective questions about this subject were distributed, of which 105 questionnaires were correctly filled and collected after 30 days. Concluding, all of the questions that the orthodontists were answered, to 37%, the level of knowledge for the others traumatism questions was considered not satisfactory and about orthodontic movement in traumatized teeth approximately 40% of the interviewed professionals not answered correctly.
440

Resistência adesiva de bráquetes ortodônticos colados com sistemas adesivos convencionais e auto-condicionantes ao esmalte bovino após ciclos térmicos e termomecânicos

Torres, Luciana Marcondes Sarmento [UNESP] 29 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-29Bitstream added on 2014-06-13T20:31:05Z : No. of bitstreams: 1 torres_lms_me_sjc.pdf: 1289584 bytes, checksum: a62d84cf9380d80ba27b908f64260c42 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo in vitro teve como objetivo avaliar a influência das ciclagens térmica e termomecânica na resistência adesiva de bráquetes colados em esmalte bovino com primers convencionais e auto-condicionates. Noventa incisivos bovinos foram aleatoriamente divididos em 2 grupos (G), de acordo com o primer utilizado: XT (n=45) – bráquetes colados com primer convencional (Transbond XT/3M, Unitek); SEP (n=45) – bráquetes colados com primer auto-condicionante (Transbond Plus SEP/3M, Unitek). Após a colagem dos bráquetes, cada grupo foi subdividido em 3 subgrupos (n=15): SC (sem ciclagem) – as amostras não receberam nenhum tipo ciclagem; CT (ciclagem térmica) – as amostras receberam apenas ciclagem térmica (500 ciclos de 50C a 550C); CTM (ciclagem termomecânica) – as amostras receberam ciclagem termomecânica (100.000 ciclos de 50C a 550C). A seguir, foi realizado o teste de cisalhamento em uma máquina de ensaios universal (EMIC) a uma velocidade de 1mm/min com célula de carga de 100kg. Após o descolamento dos bráquetes, amostras de cada grupo foram submetidas à avaliação microscópica em microscópio eletrônico de varredura, a fim de analisar a superfície do esmalte e quantificar o Índice de Adesivo Remanescente (IAR) sobre a superfície. Os resultados mostraram que o grupo SEP apresentou maior resistência adesiva (14,70±4,85 MPa) quando comparado com o grupo XT (11,27±4,48 MPa). Para os grupos XT, a resistência adesiva manteve-se semelhante independente do tipo de ciclagem (SC, 11,44 MPa; CT, 11,20 MPa; CTM,11,19 MPa), enquanto que para os grupos SEP o subgrupo CTM foi o que apresentou maiores valores de resistência adesiva (16,84 MPa), seguido do CT (14,99 MPa) e SC (12,26 MPa). O teste ANOVA - 2 fatores revelou que o efeito interação não é estatisticamente significante; indicando, assim, que o efeito do tipo de ciclagem para o grupo XT é o mesmo... / The aim of this in vitro study was to evaluate the influence of thermal and thermomechanical cycling on shearbond strength of orthodontic brackets bonded with conventional and self-etching primers. 90 bovine incisors were randomly divided into 2 groups (G) according to the primer: XT (n=45) – brackets bonded with conventional primer (Transbond XT/3M, Unitek); SEP (n=45) – brackets bonded with self-etching primer (Transbond Plus SEP/3M, Unitek). After bonding, each group were divided into 3 subgroups (n=15): NC (no cycling) – the specimens did not receive any kind of cycling; TC (thermal cycling) – the specimens received only thermal cycling (500 cycles); TMC (thermomechanical cycling) – the specimens received thermomechanical cycling (100.000 cycles). Next, the shearbond strength test was performed in a universal testing machine (EMIC) at a crosshead speed of 1mm/min. After debonding, specimens of each group were submitted to microscopic evaluation in order to analyze the enamel surface, the adhesive penetration and quantify the Adhesive Remaining Index (ARI). The results showed that the SEP group presented higher bond strength (14,70±4,85 MPa) compared with XT (11,27±4,48 MPa). For XT, the bond strength remained similar despite cycling (NC, 11,44 MPa; TC, 11,20 MPa; TMC,11,19 MPa), meanwhile for SEP, the subgroup TMC showed higher values of bond strength (16,84 MPa), followed by TC (14,99 MPa) e NC (12,26 MPa). 2-way ANOVA test indicated that the interaction effect is not statistically different, so the kind of cycling effect for XT is equal for SEP. But the primer effect (XT vs SEP) is statiscally significant. According to the ARI , the group that presented the highest remaining adhesive on the enamel surface was SEP/TMC (ARI=3). The results showed that self-etching primers can be safely used in orthodontic practice because presents adequate values of bond strength ... (Complete abstract click electronic access below)

Page generated in 0.067 seconds