• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • Tagged with
  • 20
  • 14
  • 7
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise da influência do tempo de centelhamento para diferentes métodos de refrigeração na retificação

Fernandes, Ulysses de Barros [UNESP] 30 September 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:21Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-09-30Bitstream added on 2014-06-13T18:57:22Z : No. of bitstreams: 1 fernandes_ub_me_bauru.pdf: 543795 bytes, checksum: 581262bb224ded4effc598e684a95572 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A operação de retificação cilíndrica externa de mergulho têm sido bastante empregada no processo de fabricação de componentes que necessitem de excelente qualidade superficial obtida dentro de baixos níveis de tolerância dimensional. O tempo de centelhamento spark-out) é um parâmetro que permite que se alcance as dimensões desejadas, por meio da eliminação das deformações elásticas oriundas das intensas forças que agem na interface de contato peçaferramenta. O tempo de spark-out é definido como um período de inexistência de avanços do rebolo, todavia com remoção de material da peça que busca o posicionamento real. A experimentação envolvendo o tempo de centelhamento será aplicada na operação de retificação utilizando três métodos de lubri-refrigeração, sendo eles convencional, otimizado e MQL (Mínima Quantidade de Lubrificação) para que, desta forma, seja possível fazer uma otimização global do processo. Optou-se por trabalhar com a técnica de MQL pelo fato desta se apresentar como uma nova tendência capaz de proporcionar redução de custos e ainda evitar uma intensa degradação do meio-ambiente, ocasionada por fluidos convencionais. O desempenho do processo foi verificado por meio dos seguintes parâmetros de saída: força tangencial de corte, emissão acústica, rugosidade, desvios de circularidade e desgaste diametral da ferramenta abrasiva. Analisando-se os resultados constatou-se quais os tempos de spark-out mais adequados para o processo de retificação e também em quais condições de trabalho a técnica de MQL pode ser eficazmente empregada. / The cylindrical plunge grinding operation has been used in the process of manufacture of components that need excellent gotten superficial quality of low levels of dimensional accuracy. Spark-out time is a parameter that has been sufficiently used exactly for contributing for the attainment of good surfaces with satisfactory geometric precision. This time is defined as a period of inexistence of advances of abrasive tool, and has as purpose to allow that the elastic deformations appeared at the moment of the advance of abrasive tool are eliminated. The experimentation involving spark-out was applied in the grinding operation using three types of coolant application, conventional and optimized and the Minimum Quantity of Lubrification (MQL), witch has been seen as environmentally correctly way, joining a little quantity of lubrificant oil with an intensive flow of compressed air. The performance of the process was verified by the following parameters: tangential cutting force, acoustic emission, roughness, roundness and wear of abrasive tool. The results shows what the most efficient spark-out applied in the grinding process and either conditions MQL can be well applied.
12

Estudo da operação otimizada de um sistema de reservatórios considerando a evaporação através de algoritmo genético híbrido / A study of optimized operation of a system of reservoirs considering the evaporation through a hybrid genetic algorithm

Tibério Magalhães Pinheiro 22 August 2003 (has links)
Os problemas de escassez hídrica enfrentados pela região Nordeste do Brasil ocorrem, principalmente, devido às condições climáticas, caracterizadas pela má distribuição das chuvas tanto temporalmente - a maior parte da precipitação anual se concentra em poucos meses - quanto espacialmente. A alta taxa de evaporação da região e a estrutura geológica do solo, predominantemente cristalino, são fatores que contribuem para agravar o problema. Fica evidenciada, portanto, a necessidade de a operação dos sistemas de recursos hídricos ser otimizada, propiciando assim, o seu melhor aproveitamento, com o menor custo para a sociedade. O presente trabalho estuda a operação otimizada dos reservatórios que abastecem a região metropolitana de Fortaleza, no Estado do Ceará, considerando a evaporação. O problema foi tratado através de um procedimento híbrido, proposto recentemente, de algoritmo genético e programação linear. O método permitiu que regras operacionais fossem extraídas sem a necessidade de fixá-las a priori, considerando diferentes condições de importe hídrico e possibilidades hidrológicas para evidenciar a robustez do método. / The problems of water shortage in the Northeast area of Brazil, are mainly due to the weather conditions, characterized by scattered rainfall depending upon the time of the year - the highest annual precipitation is concentrated in a few months - as well as the location. Very high evaporation rates in the region and the geological structure of the soil, mainly of crystalline origin, are factors that worsen shortage of water. Thus, there need for optimal operation of water resources systems, so as to obtain highest benefit at low costs for the society. The present study performs optimized operation of the Fortaleza (Ceará) metropolitan area water supply reservoirs with special attention to water losses by evaporation. The problem has been handled through a recently proposed hybrid procedure, genetic algorithm and linear programming. The method permitted extraction of operational rules without having to hypothesize their structure \"a priori\". Further, it was applied to Fortaleza water supply under different hydrologic conditions and those of inter-basin water transfers to verify the strength of the method employed.
13

[pt] APRENDIZADO EM DOIS ESTÁGIOS PARA MÉTODOS DE COMITÉ DE ÁRVORES DE DECISÃO / [en] TWO-STAGE LEARNING FOR TREE ENSEMBLE METHODS

ALEXANDRE WERNECK ANDREZA 23 November 2020 (has links)
[pt] Tree ensemble methods são reconhecidamente métodos de sucesso em problemas de aprendizado supervisionado, bem como são comumente descritos como métodos resistentes ao overfitting. A proposta deste trabalho é investigar essa característica a partir de modelos que extrapolem essa resistência. Ao prever uma instância de exemplo, os métodos de conjuntos são capazes de identificar a folha onde essa instância ocorre em cada uma das árvores. Nosso método então procura identificar uma nova função sobre todas as folhas deste conjunto, minimizando uma função de perda no conjunto de treino. Uma das maneiras de definir conceitualmente essa proposta é interpretar nosso modelo como um gerador automático de features ou um otimizador de predição. / [en] In supervised learning, tree ensemble methods have been recognized for their high level performance in a wide range of applications. Moreover, several references report such methods to present a resistance of to overfitting. This work investigates this observed resistance by proposing a method that explores it. When predicting an instance, tree ensemble methods determines the leaf of each tree where the instance falls. The prediction is then obtained by a function of these leaves, minimizing a loss function or an error estimator for the training set, overfitting in the learning phase in some sense. This method can be interpreted either as an Automated Feature Engineering or a Predictor Optimization.
14

Manejo da irriga??o com d?ficit h?drico controlado no cultivo org?nico da cenoura (Daucus carota) / Irrigation management with water deficit controlled in organic cultivation of carrot (Daucus carota).

Concei??o, Bruno C?sar L?llis 29 July 2015 (has links)
Submitted by Sandra Pereira (srpereira@ufrrj.br) on 2017-03-31T11:38:34Z No. of bitstreams: 1 2015 - Bruno C?sar L?llis Concei??o.pdf: 1515220 bytes, checksum: a05f88b94d301561f77c60c2076ef313 (MD5) / Made available in DSpace on 2017-03-31T11:38:34Z (GMT). No. of bitstreams: 1 2015 - Bruno C?sar L?llis Concei??o.pdf: 1515220 bytes, checksum: a05f88b94d301561f77c60c2076ef313 (MD5) Previous issue date: 2015-07-29 / Conselho Nacional de Desenvolvimento Cient?fico e Tecnol?gico - CNPq / The crop simulation models are tools used to assist in the management of the available resources. For the carrot crop, few studies have examined the effect of irrigation with deficits in their performance and quality of crops. The optimization of the regulated deficit irrigation strategy (ORDI), which integrates the economic optimization model for irrigation water management (MOPECO), determines the level of deficit to be achieved at each stage of crop development in order to maximize the performance for a given level of deficit. The study was conducted in 2013 and 2014 in the Integrated Agroecological Production - SIPA, located in Serop?dica-RJ, Brazil. It was used drip irrigation system with a line for each two lines of cultivation, emitter spacing of 10 cm and flow rate of 4 L h-1 m-1. Two deficit irrigation application methods were evaluated (constant water deficit - CHD and ORDI). For both methods were applied 5 different levels of global deficit (90, 80, 70 and 60% of crop evapotranspiration (ETm), and without irrigation), besides the treatment with 100% ETm. In the two years evaluated no statistically significant differences were obtained in total yields between ORDI and CHD, for the same level of deficit used. However, a high percentage of the roots obtained from the CHD strategy had shortcomings in terms of quality (defects, improper size, cracks, etc.) provided decrease in commercial production. Therefore, for the same volume of water applied, irrigation management made by ORDI was more efficient, reaching 50% and 24% more commercial productivity in the treatment ETm 0.6 and other treatments, respectively / Os modelos de simula??o de cultivos s?o ferramentas utilizadas para auxiliar no gerenciamento dos recursos dispon?veis. Para o cultivo de cenoura, poucos estudos examinaram o efeito da irriga??o com d?ficit em seu desempenho e qualidade das colheitas. O d?ficit otimizado por etapas (DOTI), metodologia integrada ao Modelo de otimiza??o econ?mica da ?gua de irriga??o (MOPECO), determina o n?vel de d?ficit a ser atingido em cada fase do desenvolvimento da cultura visando maximizar seu desempenho, para um determinado n?vel de d?ficit a ser obtido no ciclo. O estudo foi conduzido em 2013 e 2014, no Sistema Integrado de Produ??o Agroecol?gica - SIPA, localizada em Serop?dica-RJ, Brasil. O sistema de irriga??o usado foi de gotejamento, com uma fita gotejadora para cada duas linhas de cultivo, espa?amento entre emissores de 10 cm e vaz?o de 4 L h-1 m-1. Dois m?todos de aplica??o de irriga??o com d?ficit foram avaliados, sendo denominados d?ficit h?drico constante (DHC) e DOTI. Para ambos os m?todos foram aplicados 5 diferentes n?veis de d?ficit global (90, 80, 70 e 60% do potencial de evapotranspira??o da cultura (ETm), e sem irriga??o), al?m do tratamento com 100% da ETm. Os resultados demonstram que nos dois anos de ensaios de campo n?o foram obtidas diferen?as estatisticamente significativas dos rendimentos totais entre DOTI e DHC, para o mesmo n?vel de d?ficit h?drico utilizado. No entanto, uma alta porcentagem das ra?zes obtidas com a estrat?gia DHC apresentaram defici?ncias em termos de qualidade (defeitos, tamanhos inadequados, rachaduras, etc.) que proporcionaram diminui??o na produ??o comercial. Por conseguinte, para o mesmo volume de ?gua aplicado, o manejo da irriga??o efetuado pelo DOTI foi mais eficiente, atingindo 50% a mais de produtividade comercial no tratamento 0,6 ETm e cerca de 24% para os demais tratamentos
15

Comparação entre os métodos convencional e com bocal modificado de aplicação de fluido de corte no processo de retificação cilíndrica interna

Biscioni, Ricardo Pio Barakat [UNESP] 02 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:21Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-02Bitstream added on 2014-06-13T20:17:59Z : No. of bitstreams: 1 biscioni_rpb_me_bauru.pdf: 662612 bytes, checksum: 0ffafb03e1fbe94047f45b65deb9ebd0 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Um processo muito utilizado na indústria metal-mecânica em geral para fabricação de componentes de responsabilidade é a operação de retificação cilíndrica interna de precisão, este processo é utilizado, por exemplo, na fabricação de anéis de rolamento e outros componentes. Atualmente a evolução das máquinas permitiu o aprimoramento deste processo no que diz respeito ao posicionamento e à rigidez do sistema máquina-peça-ferramenta, porém ainda são enfrentados grandes problemas quanto à lubrificação e refrigeração, principalmente no que diz respeito à utilização de fluidos de corte. Este trabalho visa o estudo do comportamento da operação de retificação cilíndrica interna de mergulho a alta velocidade, no processo de acabamento de um aço endurecido SAE 52100, utilizando-se um rebolo convencional e dois métodos de refrigeração: o método de refrigeração convencional e com um bocal modificado. O motivo para o emprego de um bocal modificado reside no fato de se encontrar uma alternativa viável para uma possível substituição do método convencional que consome grande quantidade de fluido, já que estes têm se tornando nas últimas décadas um grande problema para as indústrias, devido aos enormes dados ambientais e humanos que causam. Para efetivar a comparação entre os métodos de refrigeração foram analisados os dados a respeito da rugosidade, erros de circularidade e desgaste diametral do rebolo, além de análise de microdureza e MEV das amostras retificadas para os métodos de refrigeração citados anteriormente. Analisando os resultados a quebra de barreira aerodinâmica e a melhor eficiência da penetração do fluido de corte na região de contato entre o rebolo e a peça foi maior quando se utilizou o bocal modificado com vazão de 21 1/min (25 m/s); os resultados de rugosidade, erro de circularidade e desgaste do rebolo foram sempre... / Precision internal plunge grinding is a process much used in the mechanical industry in general
16

A localização de faltas em um sistema de distribuição radial baseada na aplicação de árvores de decisão e redes neurais artificiais / Fault location in a radial distribution system based on the application of decision trees and artificial neural networks

Pessoa, André Luís da Silva 02 August 2017 (has links)
Os Sistemas de Distribuição (SDs), devido as suas topologias e configurações, dentre outros fatores, apresentam um desafio para a localização física das situações de faltas passíveis de ocorrência. Como fato, tem-se que uma localização de faltas, rápida e precisa, possibilita atenuar os transtornos que os usuários finais dos SDs viriam a ter em relação à qualidade do serviço prestado pelas distribuidoras. No contexto das redes elétricas inteligentes, e considerando medidores de qualidade da energia elétrica previamente alocados de forma otimizada, esta pesquisa propõe uma metodologia baseada em árvores de decisão e redes neurais artificiais para a localização de faltas em SDs radiais e aéreos. Foram realizados testes da metodologia proposta considerando variações no tipo, na impedância e no ângulo de incidência da falta aplicadas sobre o SD de 34 barras do IEEE (Institute of Electrical and Electronics Engineers). Para os testes de sensibilidade da metodologia desenvolvida, foram consideradas variações no carregamento do sistema, os erros inerentes ao sistema de medição, a variação no número de medidores disponível, o impacto de uma alocação não otimizada dos medidores e uma redução na taxa amostral. Os resultados encontrados foram promissores e indicam que a metodologia como desenvolvida poderá ser aplicada para SDs diferentes do caso teste utilizado. / Due to the distribution systems (DS) topologies, configurations and among other factors, it is a challenge to physically locate situations of faults. As a matter of fact, a fast and accurate fault location will make it possible to mitigate the inconvenience that the end users of DS would have due to the quality of the service provided by the distributors. In the context of intelligent electric grids, and considering the electric power quality meters optimally alocated, this research proposes a methodology based in decision trees and artificial neural networks for a fault location in radial and aerial DS. The proposed methodology was tested considering variations on the type, impedance and angle of incidence of the fault applied on the DS of 34 bars of the IEEE (Institute of Electrical and Electronic Engineers). For a sensitivity test of the developed methodology, it were considered the variations in system loading, the errors inherent to the measurement system, a variation in number of meters available, the impact of the non-optimized allocation of the meters and a redution on the sampling rate. The results were promising and indicated that the methodology developed can be applied to different DS from the test case used.
17

Diagnóstico de curtos-circuitos a partir da alocação otimizada de medidores em um sistema de distribuição subterrâneo / Diagnostic short-circuits from the optimized allocation meters in a underground distribution system

Festa, Alexandre Vinícius 12 February 2015 (has links)
O monitoramento e diagnóstico, com a consequente localização dos curtos-circuitos em Sistemas de Distribuição (SD), fazem parte de um processo complexo, exigindo esforços e agilidade das equipes técnicas de manutenção das concessionárias de energia elétrica. Quando se trata de um SD Subterrâneo (SDS), a complexidade de localização das faltas aumenta, pois não é possível realizar a inspeção visual. Por este motivo, desenvolver e aprimorar métodos para monitorar, classificar e localizar as situações de faltas em SD tem sido de relevante interesse para a comunidade técnico-científica nos últimos anos. Neste contexto, apresenta-se nesta pesquisa um método para processar as informações necessárias para classificar e localizar a ocorrência de um curto-circuito (monofásico, bifásico e/ou trifásico, com e/ou sem o envolvimento da terra) em um SDS. O processamento das informações foi realizado por meio da observação da propagação dos afundamentos de tensão, decorrentes de curtos-circuitos passíveis de ocorrência no SDS, e pela alocação de um número reduzido de medidores, permitindo a classificação e localização precisa da falta. Um dos diferenciais da metodologia proposta é que esta utiliza somente os valores eficazes das tensões trifásicas, registradas em medidores estrategicamente alocados, para indicação da área afetada e classificação das fases envolvidas. A metodologia é baseada no emprego de redes neurais artificiais. Os resultados encontrados são promissores, indicando a aplicabilidade da metodologia proposta. / The monitoring and diagnostics, with the consequent localization of short circuits in Distribution Systems (DS), are part of a complex process, requiring efforts and agility of the technical teams of maintenance of electric utilities. In the case of an underground DS (UDS), the location of faults complexity increases, because it is not possible to perform visual inspection. For this reason, develop and improve methods to monitor, sort and locate the fault situations in DS has been of relevant interest to the technical-scientific community in recent years. In this context, this study presents a method for processing the information required to classify and locate the occurrence of a short circuit (single phase, biphasic and / or phase with and / or without the involvement of the earth) on a UDS. The information processing was carried out by observing the propagation of voltage sags, caused by short circuits that may occur in the UDS, and the allocation of a few meters, allowing classification and precise location of the fault. One of the proposed methodology differentials is that it uses only the RMS values of the three-phase voltages, registered in strategically located meters, for indicating the affected area and classification of the phases involved. The methodology is based on the use of artificial neural networks. The results found are promising, indicating the applicability of the proposed methodology.
18

Diagnóstico de curtos-circuitos a partir da alocação otimizada de medidores em um sistema de distribuição subterrâneo / Diagnostic short-circuits from the optimized allocation meters in a underground distribution system

Alexandre Vinícius Festa 12 February 2015 (has links)
O monitoramento e diagnóstico, com a consequente localização dos curtos-circuitos em Sistemas de Distribuição (SD), fazem parte de um processo complexo, exigindo esforços e agilidade das equipes técnicas de manutenção das concessionárias de energia elétrica. Quando se trata de um SD Subterrâneo (SDS), a complexidade de localização das faltas aumenta, pois não é possível realizar a inspeção visual. Por este motivo, desenvolver e aprimorar métodos para monitorar, classificar e localizar as situações de faltas em SD tem sido de relevante interesse para a comunidade técnico-científica nos últimos anos. Neste contexto, apresenta-se nesta pesquisa um método para processar as informações necessárias para classificar e localizar a ocorrência de um curto-circuito (monofásico, bifásico e/ou trifásico, com e/ou sem o envolvimento da terra) em um SDS. O processamento das informações foi realizado por meio da observação da propagação dos afundamentos de tensão, decorrentes de curtos-circuitos passíveis de ocorrência no SDS, e pela alocação de um número reduzido de medidores, permitindo a classificação e localização precisa da falta. Um dos diferenciais da metodologia proposta é que esta utiliza somente os valores eficazes das tensões trifásicas, registradas em medidores estrategicamente alocados, para indicação da área afetada e classificação das fases envolvidas. A metodologia é baseada no emprego de redes neurais artificiais. Os resultados encontrados são promissores, indicando a aplicabilidade da metodologia proposta. / The monitoring and diagnostics, with the consequent localization of short circuits in Distribution Systems (DS), are part of a complex process, requiring efforts and agility of the technical teams of maintenance of electric utilities. In the case of an underground DS (UDS), the location of faults complexity increases, because it is not possible to perform visual inspection. For this reason, develop and improve methods to monitor, sort and locate the fault situations in DS has been of relevant interest to the technical-scientific community in recent years. In this context, this study presents a method for processing the information required to classify and locate the occurrence of a short circuit (single phase, biphasic and / or phase with and / or without the involvement of the earth) on a UDS. The information processing was carried out by observing the propagation of voltage sags, caused by short circuits that may occur in the UDS, and the allocation of a few meters, allowing classification and precise location of the fault. One of the proposed methodology differentials is that it uses only the RMS values of the three-phase voltages, registered in strategically located meters, for indicating the affected area and classification of the phases involved. The methodology is based on the use of artificial neural networks. The results found are promising, indicating the applicability of the proposed methodology.
19

A localização de faltas em um sistema de distribuição radial baseada na aplicação de árvores de decisão e redes neurais artificiais / Fault location in a radial distribution system based on the application of decision trees and artificial neural networks

André Luís da Silva Pessoa 02 August 2017 (has links)
Os Sistemas de Distribuição (SDs), devido as suas topologias e configurações, dentre outros fatores, apresentam um desafio para a localização física das situações de faltas passíveis de ocorrência. Como fato, tem-se que uma localização de faltas, rápida e precisa, possibilita atenuar os transtornos que os usuários finais dos SDs viriam a ter em relação à qualidade do serviço prestado pelas distribuidoras. No contexto das redes elétricas inteligentes, e considerando medidores de qualidade da energia elétrica previamente alocados de forma otimizada, esta pesquisa propõe uma metodologia baseada em árvores de decisão e redes neurais artificiais para a localização de faltas em SDs radiais e aéreos. Foram realizados testes da metodologia proposta considerando variações no tipo, na impedância e no ângulo de incidência da falta aplicadas sobre o SD de 34 barras do IEEE (Institute of Electrical and Electronics Engineers). Para os testes de sensibilidade da metodologia desenvolvida, foram consideradas variações no carregamento do sistema, os erros inerentes ao sistema de medição, a variação no número de medidores disponível, o impacto de uma alocação não otimizada dos medidores e uma redução na taxa amostral. Os resultados encontrados foram promissores e indicam que a metodologia como desenvolvida poderá ser aplicada para SDs diferentes do caso teste utilizado. / Due to the distribution systems (DS) topologies, configurations and among other factors, it is a challenge to physically locate situations of faults. As a matter of fact, a fast and accurate fault location will make it possible to mitigate the inconvenience that the end users of DS would have due to the quality of the service provided by the distributors. In the context of intelligent electric grids, and considering the electric power quality meters optimally alocated, this research proposes a methodology based in decision trees and artificial neural networks for a fault location in radial and aerial DS. The proposed methodology was tested considering variations on the type, impedance and angle of incidence of the fault applied on the DS of 34 bars of the IEEE (Institute of Electrical and Electronic Engineers). For a sensitivity test of the developed methodology, it were considered the variations in system loading, the errors inherent to the measurement system, a variation in number of meters available, the impact of the non-optimized allocation of the meters and a redution on the sampling rate. The results were promising and indicated that the methodology developed can be applied to different DS from the test case used.
20

Otimização da confiabilidade de sistemas de distribuição de energia elétrica: uma abordagem considerando a seleção e alocação de dispositivos de proteção e manobras / Electric distribution power systems reliability optimization: an approach considering the selection and allocation of protection and switching devices

Ferreira, Gustavo Dorneles 27 March 2009 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / One of the main goals of the electric utilities is to provide energy to its customers in a reliable and low cost way. Traditionally, the electricity sector regulatory commissions impose continuity targets, which must be carried out, to avoid great penalties. For many years, the electric utilities have adopted the practice of allowing the increment of temporary interruptions, aiming the reduction of permanent interruptions in energy supply, through coordinated protection schemes. However, due to the increase growing in electronic loads, and the existence of complex power-driven industrial processes, there is a less tolerance in short duration interruptions events. Therefore, the reliability must be characterized as widely way, considering the occurrence of such disturbances. The definition of protection devices types, and its arrangement in the feeder, enables the restriction of faults propagation, reducing the number of consumers subject to interruptions in energy supply. Similarly, the allocation of switching devices in an optimized way, provides a reduction of the interruptions duration, allowing the isolation of portions of the network subject to failure, the reconfiguration of the feeder and restoration of the supply to the consumer, in permanent interruptions cases. Targeting these factors, in this work are proposed two methods to optimize the reliability of electrical distribution systems. The optimization with a single objective is based on optimized allocation of protective and switching devices in the feeder, aiming the minimization of the reliability indices that considers the occurrence of permanent interruptions in energy supply. It is possible the choice of different indices, considering parameters such as load, number of consumers, and energy costs related to the occurrence of interruptions. The protection scheme, in this case is pre-defined (coordinated or selective), and applied to all reclosers allocated in the process of optimization, as well as the breaker of the substation. The second methodology - called double objective - is based on simultaneous minimization of reliability index that take into account the occurrence of permanent interruptions, and the indicator MAIFIE (Momentary Average Interruption Event Frequency Index), which considers the incidence of events that cause temporary interruptions in energy supply. Thus, besides the allocation of protection and switching devices, the optimization consists in definition of the protection scheme to be employed in reclosers and circuit breaker at the substation. Both formulations result in models of nonlinear programming with discontinuous and non-differentiable objective functions, subject to non-linear restrictions. These restrictions reflect in economic and technical limitations, such as coordination and selectivity between the protective devices, topology of the feeder, maximum number of devices available for allocation, and others. In order to find the best solution of the problem with single objective, a Simple Genetic Algorithm is proposed. A conjunct of best solutions of the dual objective problem was accomplished by using Multiobjective Genetic Algorithm. Among these, the most appropriate solution is selected through the use of Fuzzy Inference System. The performance of the algorithms and the quality of the solutions were verified by submitting a real 421 bus distribution system in the process of optimization. The results are commented and compared with the commonly practices used by electric companies. / Uma das principais metas das empresas concessionárias é fornecer energia a seus clientes de forma confiável e com baixo custo. Tradicionalmente, órgãos reguladores do setor elétrico estabelecem metas de continuidade, que devem ser satisfeitas sob pena da aplicação de vultosas multas. Durante muitos anos, as concessionárias têm adotado a prática de permitir o incremento das interrupções temporárias, visando à diminuição na ocorrência das interrupções permanentes no fornecimento de energia, pelo emprego do esquema de proteção coordenado. Entretanto, com o crescente aumento das cargas eletrônicas, e a existência de processos industriais automatizados cada vez mais complexos, existe uma menor tolerância à ocorrência de interrupções de curta duração. Logo, a confiabilidade deve ser caracterizada de forma mais ampla, considerando a ocorrência deste tipo de distúrbio. A definição dos tipos de dispositivos de proteção, e a disposição dos mesmos em locais específicos do alimentador, possibilitam restringir a propagação de faltas, reduzindo o número de consumidores submetidos a interrupções no fornecimento de energia. De forma semelhante, a alocação de chaves de manobras de maneira otimizada provê meios de reduzir a duração das interrupções, possibilitando a isolação de trechos da rede sob condição de falta, a reconfiguração do alimentador e o restabelecimento do fornecimento à parte dos consumidores, caso ocorram interrupções permanentes. Visando estes fatores, neste trabalho são propostas duas metodologias de otimização da confiabilidade de sistemas elétricos de distribuição. A otimização com objetivo único consiste na alocação de dispositivos de proteção e manobras no alimentador, visando à minimização de indicadores de confiabilidade que consideram a ocorrência de interrupções permanentes no fornecimento de energia. É possível a escolha de diferentes indicadores, considerando parâmetros como: carga, número de consumidores, energia e custos relacionados à ocorrência de interrupções. O esquema de proteção, neste caso é pré-definido (coordenado ou seletivo), sendo aplicado a todos os religadores alocados no processo de otimização, inclusive ao disjuntor da subestação. A segunda metodologia denominada duplo objetivo consiste na minimização simultânea de um indicador de confiabilidade que considera a ocorrência de interrupções permanentes, e do indicador MAIFIE (Momentary Average Interruption Event Frequency Index), que considera a ocorrência de eventos causadores de interrupções temporárias no fornecimento de energia. Desta forma, além da alocação dos dispositivos de proteção e manobras, o processo de otimização visa definir o esquema de proteção a ser empregado nos religadores, bem como no disjuntor da subestação. Ambas as formulações resultam em modelos de programação não-lineares, com funções objetivo descontínuas e não diferenciáveis, sujeitas a restrições não-lineares. Estas restrições refletem limitações técnicas e econômicas, tais como coordenação e seletividade entre os dispositivos de proteção, topologia do alimentador, número máximo de dispositivos disponíveis para alocação, entre outras. Na busca da melhor solução do problema com objetivo único é empregado o Algoritmo Genético Simples. Um conjunto de soluções ótimas do problema duplo objetivo é obtido utilizando o Algoritmo Genético Multiobjetivo. Dentre estas, a solução mais adequada é selecionada por meio de um Sistema de Inferência Nebulosa. O desempenho dos algoritmos e a qualidade das soluções foram verificados submetendo um sistema de distribuição real de 421 barras ao processo de otimização. Por fim, os resultados são comentados e comparados com as práticas mais utilizadas pelas concessionárias.

Page generated in 0.0521 seconds