• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 7
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da liberação de flúor de resinas compostas em água e ciclagem de pH / Evaluation of the fluoride release from composed resins in water and in pH - cycling system.

Garcez, Rosa Maria Viana de Braganca 01 March 2001 (has links)
O flúor tem um papel importante na estrutura dentária diminuindo a desmineralização e potencializando a remineralização. É fundamental conhecer o comportamento dos materiais restauradores no que diz respeito a liberação de flúor, não só em água deionizada, mas também em condições de desafio ácido. O objetivo desse trabalho foi avaliar a liberação de flúor de 6 materiais restauradores, em dois meios de imersão, água deionizada e sistema de ciclagem de pH entre, por 15 dias. Os materiais utilizados foram o Vitremer(VIT), o Dyract (DYR), o Ariston (A), o Tetric Ceram (TET), o Definite (DEF) e o Z 100. Para cada material foram confeccionados 16 corpos-de-prova na forma de discos (11 mm de diâmetro e 1,5 mm de espessura), os quais foram armazenados individualmente em 4 ml de cada solução, sendo 8 para cada meio de imersão. Na ciclagem de pH, o material era mantido 6 horas na solução desmineralizante e 18 horas na solução remineralizante. As soluções foram trocadas diariamente e os espécimes armazenados durante 15 dias. A liberação de flúor foi medida em 0,5 ml de solução adicionada a igual volume de TISAB II. Para os materiais Z 100, DEF e TET em água deionizada, a liberação de flúor foi obtida pela técnica da difusão facilitada por HMDS, nos períodos de 1, 7 e 15 dias. A análise da concentração de flúor foi medida por eletrodo específico para flúor, acoplado ao aparelho analisador de pH/F¯. Todos os materiais liberaram mais flúor no sistema de ciclagem de pH, exceto o Ariston. O pico de liberação foi maior no 1º dia, declinando do 2º dia em diante, e alcançando níveis baixos e constantes a partir do 7 º ao 15º dia. Os resultados foram submetidos a análise de variância a 3 critérios e ao teste de Tukey (p<0,05), para as comparações múltiplas. A liberação total no período do experimento em ordem decrescente, em água deionizada, em µgF¯/mm2 , foi A (3,6603), VIT (1,7529), DYR (0,2481), TET (0,0140), DEF (0,0086) e Z 100 (0,0020) e em ciclagem de pH, VIT (3,4366), A (2,1422), DYR (1,0691), TET (0,0297), Z 100 (0,0067) e DEF (0,0063). Assim concluímos que os materiais apresentaram padrão semelhante de liberação de flúor, exceto o Ariston, que mostrou comportamento estável e liberação constante durante os 15 dias, nos dois meios de imersão. Na ciclagem de pH, houve uma tendência de liberação de flúor de todos os materiais. / The fluoride has an important function in the dental structure reducing the desmineralization and increase the remineralization. It is fundamental to know the behavior of the restoratives materials relative the fluoride release, not only in deionized water, but also in conditions of acid challenge. The aim of the present study was to determine the fluoride release from 6 restoratives materials, in two storage solutions: deionized water and pH-cycling system solution over 15 days. 16 discs (11 mm diameter and 1,5 mm thickness) of materials, Vitremer (VIT), Dyract (DYR), Ariston pHc (A), Tetric Ceram (TET), Definite (DEF) and Z 100 were prepared and suspended individually in 4 mL of each solution, in number of 8 for each medium which was changed every 24 hours. In the pH-cycling system the specimens were immersed 6 hours in the demineralizing solution (pH 4,3) and 18 hours in remineralizing solution (pH 7,0). The solutions were changed daily during a period of 15 days. The fluoride release was determined after buffering the solutions with an equal volume of TISAB II. For the materials Z 100, DEF, TET in deionized water, the fluoride concentration was obtained by the microdiffusion method (Taves) in the periods of 1, 7 and 15 days. The analysis of the fluoride ion concentration in the solutions was measured using a fluoride ion sensitive electrode and a potent iometer ion-analyzer pH/F¯. The results of fluoride concentration in solutions eretransformed into released fluoride amount per material area (µgF¯/mm 2 ). All the materials released more fluoride in the pH-cycling system, exception Ariston. The release peak was larger in the 1st day, dropped at the 2nd and then remained constant from 7º to 15th day. The Ariston showed stable behavior, with small variations along the experiment. The results were submited to statistical analysis by ANOVA and the diferences between the treatments by the Tukey test (p<0,05). In deionized water, fluoride release in mgF¯/mm 2 was A(3,6603), VIT(1,7529), DYR (0,2481), TET (0,0140), DEF (0,0086) and Z 100 (0,0020) and, in pH-cycling system VIT (3,4366), A (2,1422), DYR (1,0691), TET (0,0297), Z 100 (0,0067) and DEF (0,0063), during the whole experimental period.
2

Avaliação da liberação de flúor de resinas compostas em água e ciclagem de pH / Evaluation of the fluoride release from composed resins in water and in pH - cycling system.

Rosa Maria Viana de Braganca Garcez 01 March 2001 (has links)
O flúor tem um papel importante na estrutura dentária diminuindo a desmineralização e potencializando a remineralização. É fundamental conhecer o comportamento dos materiais restauradores no que diz respeito a liberação de flúor, não só em água deionizada, mas também em condições de desafio ácido. O objetivo desse trabalho foi avaliar a liberação de flúor de 6 materiais restauradores, em dois meios de imersão, água deionizada e sistema de ciclagem de pH entre, por 15 dias. Os materiais utilizados foram o Vitremer(VIT), o Dyract (DYR), o Ariston (A), o Tetric Ceram (TET), o Definite (DEF) e o Z 100. Para cada material foram confeccionados 16 corpos-de-prova na forma de discos (11 mm de diâmetro e 1,5 mm de espessura), os quais foram armazenados individualmente em 4 ml de cada solução, sendo 8 para cada meio de imersão. Na ciclagem de pH, o material era mantido 6 horas na solução desmineralizante e 18 horas na solução remineralizante. As soluções foram trocadas diariamente e os espécimes armazenados durante 15 dias. A liberação de flúor foi medida em 0,5 ml de solução adicionada a igual volume de TISAB II. Para os materiais Z 100, DEF e TET em água deionizada, a liberação de flúor foi obtida pela técnica da difusão facilitada por HMDS, nos períodos de 1, 7 e 15 dias. A análise da concentração de flúor foi medida por eletrodo específico para flúor, acoplado ao aparelho analisador de pH/F¯. Todos os materiais liberaram mais flúor no sistema de ciclagem de pH, exceto o Ariston. O pico de liberação foi maior no 1º dia, declinando do 2º dia em diante, e alcançando níveis baixos e constantes a partir do 7 º ao 15º dia. Os resultados foram submetidos a análise de variância a 3 critérios e ao teste de Tukey (p<0,05), para as comparações múltiplas. A liberação total no período do experimento em ordem decrescente, em água deionizada, em µgF¯/mm2 , foi A (3,6603), VIT (1,7529), DYR (0,2481), TET (0,0140), DEF (0,0086) e Z 100 (0,0020) e em ciclagem de pH, VIT (3,4366), A (2,1422), DYR (1,0691), TET (0,0297), Z 100 (0,0067) e DEF (0,0063). Assim concluímos que os materiais apresentaram padrão semelhante de liberação de flúor, exceto o Ariston, que mostrou comportamento estável e liberação constante durante os 15 dias, nos dois meios de imersão. Na ciclagem de pH, houve uma tendência de liberação de flúor de todos os materiais. / The fluoride has an important function in the dental structure reducing the desmineralization and increase the remineralization. It is fundamental to know the behavior of the restoratives materials relative the fluoride release, not only in deionized water, but also in conditions of acid challenge. The aim of the present study was to determine the fluoride release from 6 restoratives materials, in two storage solutions: deionized water and pH-cycling system solution over 15 days. 16 discs (11 mm diameter and 1,5 mm thickness) of materials, Vitremer (VIT), Dyract (DYR), Ariston pHc (A), Tetric Ceram (TET), Definite (DEF) and Z 100 were prepared and suspended individually in 4 mL of each solution, in number of 8 for each medium which was changed every 24 hours. In the pH-cycling system the specimens were immersed 6 hours in the demineralizing solution (pH 4,3) and 18 hours in remineralizing solution (pH 7,0). The solutions were changed daily during a period of 15 days. The fluoride release was determined after buffering the solutions with an equal volume of TISAB II. For the materials Z 100, DEF, TET in deionized water, the fluoride concentration was obtained by the microdiffusion method (Taves) in the periods of 1, 7 and 15 days. The analysis of the fluoride ion concentration in the solutions was measured using a fluoride ion sensitive electrode and a potent iometer ion-analyzer pH/F¯. The results of fluoride concentration in solutions eretransformed into released fluoride amount per material area (µgF¯/mm 2 ). All the materials released more fluoride in the pH-cycling system, exception Ariston. The release peak was larger in the 1st day, dropped at the 2nd and then remained constant from 7º to 15th day. The Ariston showed stable behavior, with small variations along the experiment. The results were submited to statistical analysis by ANOVA and the diferences between the treatments by the Tukey test (p<0,05). In deionized water, fluoride release in mgF¯/mm 2 was A(3,6603), VIT(1,7529), DYR (0,2481), TET (0,0140), DEF (0,0086) and Z 100 (0,0020) and, in pH-cycling system VIT (3,4366), A (2,1422), DYR (1,0691), TET (0,0297), Z 100 (0,0067) and DEF (0,0063), during the whole experimental period.
3

Avaliação in vitro do efeito do laser de CO2, associado ou não à aplicação tópica de flúor, na redução da desmineralização de superfícies radiculares / In vitro evaluation of the effect of CO2 laser, associated or not the topical application of fluoride in reducing the demineralization of root surfaces

Hanashiro, Fernando Seishim 06 July 2009 (has links)
Estudos têm mostrado que a dentina pode ser modificada pelo laser pulsado de CO2 tornando-a um substrato mais ácido-resistente. Este estudo in vitro se propôs a avaliar o efeito do laser de CO2, associado ou não à aplicação tópica de flúor, na redução da desmineralização de superfícies radiculares humanas, utilizando um laser pulsado de comprimento de onda 10,6 m. Cinquenta superfícies radiculares humanas obtidas de vinte e cinco terceiros molares foram aleatoriamente divididas em 5 grupos (n=10) com os seguintes tratamentos de superfície: G1 Nenhum tratamento (controle negativo), G2 Flúor Fosfato Acidulado (FFA- controle positivo), G3 Laser 4,0 J/cm2, G4 Laser 4,0 J/cm2 + FFA e G5 FFA + Laser 4,0 J/cm2. Após o tratamento da superfície, os espécimes foram submetidos a 7 dias de ciclagem de pH, permanecendo diariamente em soluções desmineralizadora e remineralizadora por 3 h e 21 h, respectivamente. Após o desafio ácido, os espécimes foram avaliados para determinar a perda mineral por meio do QLF. Pode-se concluir que o laser de CO2, associado ou não à aplicação tópica de flúor, é capaz de inibir a desmineralização da superfície radicular, contudo não se observa efeito sinérgico com a associação da irradiação com laser e tratamento com flúor. / Studies have shown that dentine can be modified by pulsed CO2 laser to form a more acid-resistant substrate. This in vitro research aimed to evaluate the effect of CO2 laser, associated or not the topical application of fluoride in reducing demineralization of human root surfaces using a pulsed laser of wavelength 10.6 m. Fifty human root surfaces obtained from twenty-five third molars were randomly divided into 5 groups (n=10) with the following surface treatments: G1 - No treatment (negative control), G2 - acidulated Phosphate Fluoride (FFA-positive control), G3 - Laser 4.0 J/cm2, G4 - Laser 4.0 J/cm2 + FFA and G5 - FFA + Laser 4.0 J/cm2. After surface treatment, specimens were subjected to 7 days of cycling the pH, remaining daily remineralizadora and demineralized in solutions for 21 h and 3 h, respectively. After acid challenge, the specimens were evaluated to determine the mineral loss through QLF. It can be concluded that the CO2 laser, with or without application of topical fluoride is able to inhibit the demineralization of root surface, however do not observed synergistic effect with the combination of laser irradiation and fluoride treatment.
4

Efeito da variação do pH em modelo de ciclagem nas propriedades de materiais restauradores

Silva, Kélio Garcia [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T19:35:57Z : No. of bitstreams: 1 silva_kg_me_araca.pdf: 3519498 bytes, checksum: 8be3bbadc0092628ca71b9618deb19ae (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / Bisco Inc., Il, Usa / O objetivo deste estudo foi avaliar o efeito da variação do pH da solução desmineralizante em modelo de ciclagem de pH na dureza de superfície, liberação de flúor e característica de superfície dos materiais restauradores: Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom e Fluorofil. Foram confeccionados, para cada material, 34 corpos-de-prova que tiveram a dureza de superfície inicial (DSI) determinada após a confecção. A seguir, foram divididos em 5 grupos (n=30) de acordo com a variação de pH (4,3; 4,6; 5,0; 5,5 e 6,2) da solução desmineralizante e submetidos a períodos cíclicos em solução desmineralizante (Des-6 horas) e remineralizante (Re-18 horas) por 15 dias. Decorrido este período, verificou-se a dureza de superfície final (DSF) e a característica de superfície (n=24). As soluções armazenadas diariamente foram utilizadas para a determinação da concentração de flúor (Des+Re). As variáveis DSI, DSF e alteração de dureza de superfície (% ADS) foram submetidas à análise de variância e a liberação de flúor ao teste de Kruskal-Wallis (p<0,05). A variação do pH proporcionou relação direta quando se comparou a dureza e inversa para a liberação de flúor nos cimentos de ionômero de vidro. Para as resinas compostas modificadas por poliácidos foi verificada relação inversa para a liberação de flúor, não havendo correlação na dureza. A característica de superfície foi influenciada pela variação do pH, ficando mais evidente nos menores pHs, exceto para as resinas compostas modificadas por poliácidos. Baseados nos resultados, concluiu-se que a variação do pH da solução desmineralizante do modelo de ciclagem influenciou a liberação de flúor dos materiais testados. Essa variação alterou a dureza e a característica de superfície dos cimentos de ionômero de vidro, mas não das resinas compostas modificadas por poliácidos. / The aim of this study was to evaluate the effect of pH of the demineralizing solution in a cycling model on surface hardness, fluoride release and surface aspects of restorative materials (Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom and Fluorofil). Thirty-four specimens of each material were made and surface hardness was measured. Then, the specimens were randomized in five groups (n=30), according to pH (4.3; 4.6; 5.0; 5.5; and 6.2) of the demineralizing solution and submitted to a cycling model during 15 days. The specimens remained in the demineralizing solution for 6 hours and in the remineralizing solution for 18 hours. After that, surface hardness was measured again and surface aspects were observed (n=24). Fluoride concentration was determined daily in all solutions (De+Re). Data from SMH (before and after pH-cycling) and %SMHC were analyzed by analysis of variance (p<0.05); Kruskal-Wallis test was carried out for the results of fluoride release. For glass ionomer cements, the variation of pH led to a direct relationship when hardness was compared and to an inverse relationship with regards to fluoride release. For polyacid-modified resin composites, an inverse relationship was found regarding fluoride release; no correlation was observed with regards to hardness. Surface aspect was influenced by pH variation: an acidic pH led to a greater alteration, except for polyacid-modified resin composites. It was possible to conclude that pH of the demineralizing solution did influence fluoride release from the tested materials. The pH variation altered hardness and surface aspects of glass ionomer cements, but it did not influence polyacid-modified resin composites in those analysis.
5

Avaliação in vitro do efeito do laser de CO2, associado ou não à aplicação tópica de flúor, na redução da desmineralização de superfícies radiculares / In vitro evaluation of the effect of CO2 laser, associated or not the topical application of fluoride in reducing the demineralization of root surfaces

Fernando Seishim Hanashiro 06 July 2009 (has links)
Estudos têm mostrado que a dentina pode ser modificada pelo laser pulsado de CO2 tornando-a um substrato mais ácido-resistente. Este estudo in vitro se propôs a avaliar o efeito do laser de CO2, associado ou não à aplicação tópica de flúor, na redução da desmineralização de superfícies radiculares humanas, utilizando um laser pulsado de comprimento de onda 10,6 m. Cinquenta superfícies radiculares humanas obtidas de vinte e cinco terceiros molares foram aleatoriamente divididas em 5 grupos (n=10) com os seguintes tratamentos de superfície: G1 Nenhum tratamento (controle negativo), G2 Flúor Fosfato Acidulado (FFA- controle positivo), G3 Laser 4,0 J/cm2, G4 Laser 4,0 J/cm2 + FFA e G5 FFA + Laser 4,0 J/cm2. Após o tratamento da superfície, os espécimes foram submetidos a 7 dias de ciclagem de pH, permanecendo diariamente em soluções desmineralizadora e remineralizadora por 3 h e 21 h, respectivamente. Após o desafio ácido, os espécimes foram avaliados para determinar a perda mineral por meio do QLF. Pode-se concluir que o laser de CO2, associado ou não à aplicação tópica de flúor, é capaz de inibir a desmineralização da superfície radicular, contudo não se observa efeito sinérgico com a associação da irradiação com laser e tratamento com flúor. / Studies have shown that dentine can be modified by pulsed CO2 laser to form a more acid-resistant substrate. This in vitro research aimed to evaluate the effect of CO2 laser, associated or not the topical application of fluoride in reducing demineralization of human root surfaces using a pulsed laser of wavelength 10.6 m. Fifty human root surfaces obtained from twenty-five third molars were randomly divided into 5 groups (n=10) with the following surface treatments: G1 - No treatment (negative control), G2 - acidulated Phosphate Fluoride (FFA-positive control), G3 - Laser 4.0 J/cm2, G4 - Laser 4.0 J/cm2 + FFA and G5 - FFA + Laser 4.0 J/cm2. After surface treatment, specimens were subjected to 7 days of cycling the pH, remaining daily remineralizadora and demineralized in solutions for 21 h and 3 h, respectively. After acid challenge, the specimens were evaluated to determine the mineral loss through QLF. It can be concluded that the CO2 laser, with or without application of topical fluoride is able to inhibit the demineralization of root surface, however do not observed synergistic effect with the combination of laser irradiation and fluoride treatment.
6

Efeito da variação do pH em modelo de ciclagem nas propriedades de materiais restauradores /

Silva, Kélio Garcia. January 2004 (has links)
Resumo: O objetivo deste estudo foi avaliar o efeito da variação do pH da solução desmineralizante em modelo de ciclagem de pH na dureza de superfície, liberação de flúor e característica de superfície dos materiais restauradores: Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom e Fluorofil. Foram confeccionados, para cada material, 34 corpos-de-prova que tiveram a dureza de superfície inicial (DSI) determinada após a confecção. A seguir, foram divididos em 5 grupos (n=30) de acordo com a variação de pH (4,3; 4,6; 5,0; 5,5 e 6,2) da solução desmineralizante e submetidos a períodos cíclicos em solução desmineralizante (Des-6 horas) e remineralizante (Re-18 horas) por 15 dias. Decorrido este período, verificou-se a dureza de superfície final (DSF) e a característica de superfície (n=24). As soluções armazenadas diariamente foram utilizadas para a determinação da concentração de flúor (Des+Re). As variáveis DSI, DSF e alteração de dureza de superfície (% ADS) foram submetidas à análise de variância e a liberação de flúor ao teste de Kruskal-Wallis (p<0,05). A variação do pH proporcionou relação direta quando se comparou a dureza e inversa para a liberação de flúor nos cimentos de ionômero de vidro. Para as resinas compostas modificadas por poliácidos foi verificada relação inversa para a liberação de flúor, não havendo correlação na dureza. A característica de superfície foi influenciada pela variação do pH, ficando mais evidente nos menores pHs, exceto para as resinas compostas modificadas por poliácidos. Baseados nos resultados, concluiu-se que a variação do pH da solução desmineralizante do modelo de ciclagem influenciou a liberação de flúor dos materiais testados. Essa variação alterou a dureza e a característica de superfície dos cimentos de ionômero de vidro, mas não das resinas compostas modificadas por poliácidos. / Abstract: The aim of this study was to evaluate the effect of pH of the demineralizing solution in a cycling model on surface hardness, fluoride release and surface aspects of restorative materials (Ketac-Fil Plus, Vitremer, Fuji II LC, Freedom and Fluorofil). Thirty-four specimens of each material were made and surface hardness was measured. Then, the specimens were randomized in five groups (n=30), according to pH (4.3; 4.6; 5.0; 5.5; and 6.2) of the demineralizing solution and submitted to a cycling model during 15 days. The specimens remained in the demineralizing solution for 6 hours and in the remineralizing solution for 18 hours. After that, surface hardness was measured again and surface aspects were observed (n=24). Fluoride concentration was determined daily in all solutions (De+Re). Data from SMH (before and after pH-cycling) and %SMHC were analyzed by analysis of variance (p<0.05); Kruskal-Wallis test was carried out for the results of fluoride release. For glass ionomer cements, the variation of pH led to a direct relationship when hardness was compared and to an inverse relationship with regards to fluoride release. For polyacid-modified resin composites, an inverse relationship was found regarding fluoride release; no correlation was observed with regards to hardness. Surface aspect was influenced by pH variation: an acidic pH led to a greater alteration, except for polyacid-modified resin composites. It was possible to conclude that pH of the demineralizing solution did influence fluoride release from the tested materials. The pH variation altered hardness and surface aspects of glass ionomer cements, but it did not influence polyacid-modified resin composites in those analysis. / Orientador: Denise Pedrini / Coorientador: Alberto Carlos Botazzo Delbem / Mestre
7

Determinação de parâmetros seguros e efetivos do laser de CO2 (?= 10,6 ?m) na redução da desmineralização da dentina radicular - Estudo in vitro / Determination of safe and effective parameters of CO2 laser (?= 10.6 ?m) on the reduction of root dentin demineralization - an in vitro study

Zaroni, Wanessa Christine de Souza 28 June 2007 (has links)
Estudos têm mostrado que a dentina pode ser modificada pelo laser pulsado de CO2 tornando-a um substrato mais ácido-resistente. Este estudo in vitro se propôs a estabelecer parâmetros seguros e efetivos de um laser pulsado de CO2 com comprimento de onda 10,6 ?m e avaliou seu efeito sobre a morfologia superficial e a composição química, assim como sobre a redução da desmineralização da dentina radicular. Noventa e cinco superfícies radiculares humanas obtidas de quarenta e oito terceiros molares foram aleatoriamente divididas em 5 grupos (n=15 para o grupo de controle e n=20 para os grupos irradiados com laser): G1 - Nenhum tratamento (controle), G2 - 2,5 J/cm2, G3 - 4,0 J/cm2, G4 - 5,0 J/cm2 e G5 - 6,0 J/cm2. A temperatura intrapulpar foi mensurada por meio de análise termográfica com termômetro de radiação infravermelha, as modificações químicas, por meio de espectroscopia FT-Raman e as alterações morfológicas por meio de microscopia eletrônica de varredura. Após o tratamento da superfície, os espécimes foram submetidos a 7 dias de ciclagem de pH, permanecendo diariamente em soluções desmineralizadora e remineralizadora por 3 h e 21 h, respectivamente. Após o desafio ácido, os espécimes foram seccionados e a perda mineral foi determinada por meio do teste de microdureza Knoop (5 g, 5 seg) em profundidades pré-determinadas em relação à superfície de dentina radicular (20 ?m - 275 ?m). Para todos os grupos irradiados, as mudanças de temperatura intrapulpar mostraram-se abaixo de 0,9°C. A espectroscopia FT-Raman não evidenciou alterações químicas entre os espécimes não-irradiados e os irradiados com laser de CO2. Entretanto a análise em microscópio eletrônico de varredura indicou que as densidades de energia a partir de 4,0 J/cm2 foram suficientes para induzir mudanças morfológicas na dentina radicular. Adicionalmente, para as densidades de energia iguais ou superiores a 4,0 J/cm2, foram observados efeitos de redução da desmineralização da dentina radicular induzidos pela irradiação laser. Pode-se concluir que densidades de energia em torno de 4,0 a 6,0 J/cm2 podem ser aplicadas à dentina radicular, a fim de promover mudanças morfológicas e reduzir a reatividade ácida da mesma, sem comprometer a vitalidade pulpar. / Studies have shown that dentin can be modified by pulsed CO2 laser to form a more acid-resistant substrate. This in vitro research aimed to establish safe parameters of a pulsed study 10.6 ?m CO2 laser and evaluate its effect on chemical and morphological features in dentinal surface, as well as on the reduction of root dentin demineralization. Ninety five human root surfaces obtained from forty eight third molars were randomly divided in 5 groups (n=15 for control group and n=20 for laser groups): G1 - No treatment (control), G2 -2.5 J/cm2, G3 - 4.0 J/cm2, G4 - 5.0 J/cm2 and G5 - 6.0 J/cm2. Intrapulpal temperature was evaluated during dentin irradiation by an infrared thermometer, chemical modifications by FT-Raman spectroscopy, and morphological modifications by SEM. After the surface treatment, the specimens were submitted to a 7 days pH-cycling model, consisted of the daily immersion in demineralizing and remineralizing solutions for 3 h and 21 h, respectively. After the acid challenge, the specimens were sectioned and the mineral loss was determined by means of cross-sectional Knoop microhardness (5 g, 5 sec) at different depths from the dentin root surface (20 ?m - 275 ?m). For all irradiated groups, intrapulpal temperature changes were below 0.9°C. FT-Raman spectroscopy did not show chemical changes in the irradiated specimens. However, scanning electron microscopy images indicated that fluences as low as 4.0 J/cm2 were sufficient to induce morphological changes in root dentin. Additionally, for fluences reaching or exceeding 4.0 J/cm2, laser-induced inhibitory effects on root dentin demineralization were observed. It was thus concluded that the laser energy density in the range of 4.0 to 6.0 J/cm2 could be applied to dental root dentin in order to produce morphological changes and reduce the acid reactivity of dentin without compromising the pulp vitality.
8

Determinação de parâmetros seguros e efetivos do laser de CO2 (?= 10,6 ?m) na redução da desmineralização da dentina radicular - Estudo in vitro / Determination of safe and effective parameters of CO2 laser (?= 10.6 ?m) on the reduction of root dentin demineralization - an in vitro study

Wanessa Christine de Souza Zaroni 28 June 2007 (has links)
Estudos têm mostrado que a dentina pode ser modificada pelo laser pulsado de CO2 tornando-a um substrato mais ácido-resistente. Este estudo in vitro se propôs a estabelecer parâmetros seguros e efetivos de um laser pulsado de CO2 com comprimento de onda 10,6 ?m e avaliou seu efeito sobre a morfologia superficial e a composição química, assim como sobre a redução da desmineralização da dentina radicular. Noventa e cinco superfícies radiculares humanas obtidas de quarenta e oito terceiros molares foram aleatoriamente divididas em 5 grupos (n=15 para o grupo de controle e n=20 para os grupos irradiados com laser): G1 - Nenhum tratamento (controle), G2 - 2,5 J/cm2, G3 - 4,0 J/cm2, G4 - 5,0 J/cm2 e G5 - 6,0 J/cm2. A temperatura intrapulpar foi mensurada por meio de análise termográfica com termômetro de radiação infravermelha, as modificações químicas, por meio de espectroscopia FT-Raman e as alterações morfológicas por meio de microscopia eletrônica de varredura. Após o tratamento da superfície, os espécimes foram submetidos a 7 dias de ciclagem de pH, permanecendo diariamente em soluções desmineralizadora e remineralizadora por 3 h e 21 h, respectivamente. Após o desafio ácido, os espécimes foram seccionados e a perda mineral foi determinada por meio do teste de microdureza Knoop (5 g, 5 seg) em profundidades pré-determinadas em relação à superfície de dentina radicular (20 ?m - 275 ?m). Para todos os grupos irradiados, as mudanças de temperatura intrapulpar mostraram-se abaixo de 0,9°C. A espectroscopia FT-Raman não evidenciou alterações químicas entre os espécimes não-irradiados e os irradiados com laser de CO2. Entretanto a análise em microscópio eletrônico de varredura indicou que as densidades de energia a partir de 4,0 J/cm2 foram suficientes para induzir mudanças morfológicas na dentina radicular. Adicionalmente, para as densidades de energia iguais ou superiores a 4,0 J/cm2, foram observados efeitos de redução da desmineralização da dentina radicular induzidos pela irradiação laser. Pode-se concluir que densidades de energia em torno de 4,0 a 6,0 J/cm2 podem ser aplicadas à dentina radicular, a fim de promover mudanças morfológicas e reduzir a reatividade ácida da mesma, sem comprometer a vitalidade pulpar. / Studies have shown that dentin can be modified by pulsed CO2 laser to form a more acid-resistant substrate. This in vitro research aimed to establish safe parameters of a pulsed study 10.6 ?m CO2 laser and evaluate its effect on chemical and morphological features in dentinal surface, as well as on the reduction of root dentin demineralization. Ninety five human root surfaces obtained from forty eight third molars were randomly divided in 5 groups (n=15 for control group and n=20 for laser groups): G1 - No treatment (control), G2 -2.5 J/cm2, G3 - 4.0 J/cm2, G4 - 5.0 J/cm2 and G5 - 6.0 J/cm2. Intrapulpal temperature was evaluated during dentin irradiation by an infrared thermometer, chemical modifications by FT-Raman spectroscopy, and morphological modifications by SEM. After the surface treatment, the specimens were submitted to a 7 days pH-cycling model, consisted of the daily immersion in demineralizing and remineralizing solutions for 3 h and 21 h, respectively. After the acid challenge, the specimens were sectioned and the mineral loss was determined by means of cross-sectional Knoop microhardness (5 g, 5 sec) at different depths from the dentin root surface (20 ?m - 275 ?m). For all irradiated groups, intrapulpal temperature changes were below 0.9°C. FT-Raman spectroscopy did not show chemical changes in the irradiated specimens. However, scanning electron microscopy images indicated that fluences as low as 4.0 J/cm2 were sufficient to induce morphological changes in root dentin. Additionally, for fluences reaching or exceeding 4.0 J/cm2, laser-induced inhibitory effects on root dentin demineralization were observed. It was thus concluded that the laser energy density in the range of 4.0 to 6.0 J/cm2 could be applied to dental root dentin in order to produce morphological changes and reduce the acid reactivity of dentin without compromising the pulp vitality.

Page generated in 0.0747 seconds