• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • 1
  • Tagged with
  • 21
  • 21
  • 16
  • 12
  • 11
  • 10
  • 10
  • 9
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Identificacao e analise dos principais radionuclideos que potencialmente contribuem para a dose interna dos trabalhadores do Centro de Radiofarmacia

SANCHES, MATIAS P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:56Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:51Z (GMT). No. of bitstreams: 1 09629.pdf: 3007133 bytes, checksum: 7b28af344b4eacb107f05cbefe8ffa4d (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
12

Exposicao ocupacional as radiacoes ionizantes nos servicos de hemodinamica

GRONCHI, CLAUDIA C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:07Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:59Z (GMT). No. of bitstreams: 1 09817.pdf: 5691046 bytes, checksum: 1bec85fbd59a2ea8a460041b09838d59 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
13

Desenvolvimento e calibracao de um dosimetro pessoal para neutrons utilizando detectores solidos de tracos nucleares

VILELA, EUDICE C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:40:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:14Z (GMT). No. of bitstreams: 1 02811.pdf: 5186762 bytes, checksum: f178f608c95e9fecbaf736562e08dae5 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:94/03409-4
14

Otimizacao no controle dos valores de radiacao nas dependencias do ciclotron de 30 MeV do IPEN

RODRIGUES, DEMERVAL L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:07Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:37Z (GMT). No. of bitstreams: 1 07969.pdf: 4735290 bytes, checksum: 35766584f698fd08a530a144cb0a0bd0 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
15

Determinação experimental dos coeficientes de conversão de Kerma no ar para o equivalente de dose pessoal, Hp(d), e fatores de retroespalhamento em feixes de raios-x diagnostico / Measurement of conversion coeficients between air kerma and personal dose equivalent and backscatter factors for diagnostic x-ray beams

Paulo Henrique Gonçalves Rosado 06 March 2008 (has links)
Em proteção radiológica dois conjuntos de grandezas são importantes, as de proteção e as operacionais. Ambas podem ser relacionadas a partir de coeficientes de conversão com grandezas físicas básicas como o kerma. Para feixes de radiação utilizados em radiodiagnóstico nas qualidades da Comissão Internacional de Eletrotécnica (IEC), os coeficientes de conversão e fatores de retroespalhamento ainda não foram determinados. É, portanto, necessário a determinação de coeficientes e fatores para a calibração dos dosímetros que serão utilizados para determinar o equivalente de dose pessoal ou a dose na entrada da pele. Foram determinados experimentalmente os coeficientes de conversão de kerma no ar para o equivalente de dose pessoal, Hp(d), e os fatores de retroespalhamento para as qualidades RQR e RQA da IEC que simulam feixes de raios X diagnósticos. Para a determinação dos coeficientes de conversão é necessário a determinação do kerma no ar dentro do simulador e a energia média do espectro. Foram utilizados dosímetros termoluminescentes do tipo 100H para a medida do kerma no ar no simulador. Os dosímetros foram calibrados utilizando uma câmara de ionização padrão terciário de 180cc da Radcal Corporation. Os dosímetros foram colocados no eixo central de um simulador tipo placa de 300 mm x 300 mm x 15 mm de polimetilmetalacrilato (PMMA) com o intuito de determinar a dose na profundidade. No procedimento de medida os dosímetros foram dispostos em cinco diferentes profundidades (5, 10, 15, 25 e 35 mm). Um outro parâmetro necessário para a determinação dos coeficientes de conversão é a energia média do espectro de raios X. A espectrometria dos feixes de raios X utilizados foi feita utilizando um detector semicondutor de CdTe. O detector foi calibrado utilizando fontes de radiação de 133Ba, 241Am e 57Co. Foram feitas correções em relação a eficiência intrínseca, absorção total de energia, fração de escape de raios X característicos, efeito Compton e atenuação devido a matérias que se encontravam entre o detector e o ponto onde foi determinado a energia média. As medidas do espectro de raios X foram corrigidas utilizado o método de stripping. Os valores das incertezas dos coeficientes de conversão e fatores de retroespalhamento foram da ordem de 12% e 6% respectivamente. / Two sets of quantities are import in radiological protection: the protection and operational quantities. Both sets can be related to basic physical quantities such as kerma through conversion coefficients. . For diagnostic x-ray beams the conversion coefficients and backscatter factors have not been determined yet, those parameters are need for calibrating dosimeters that will be used to determine the personal dose equivalent or the entrance skin dose. Conversion coefficients between air kerma and personal dose equivalent and backscatter factors were experimentally determined for the diagnostic x-ray qualities RQR and RQA recommended by the International Electrotechnical Commission (IEC). The air kerma in the phantom and the mean energy of the spectrum were measured for such purpose. Harshaw LiF-100H thermoluminescent dosemeters (TLD) were used for measurements after being calibrated against an 180 cm3 Radcal Corporation ionization chamber traceable to a reference laboratory. A 300 mm ×300 mm × 150 mm polymethilmethacrylate (PMMA) slab phantom was used for deep-dose measurements. Tl dosemeters were placed in the central axis of the x-ray beam at 5, 10, 15, 25 and 35 mm depth in the phantom upstream the beam direction Another required parameter for determining the conversion coefficients from was the mean energy of the x-ray spectrum. The spectroscopy of x-ray beams was done with a CdTe semiconductor detector that was calibrated with 133Ba, 241Am and 57Co radiation sources. Measurements of the x-ray spectra were carried out for all RQR and RQA IEC qualities. Corrections due to the detector intrinsic efficiency, total energy absorption, escape fraction of the characteristic x-rays, Compton effect and attenuation in the detector were done aiming an the accurate determination of the mean energy. Measured x-ray spectra were corrected with the stripping method by using these response functions. The typical combined standard uncertainties of conversion coefficients and backscatter factors were 12% and 6% respectively.
16

Estudo de incertezas no monitoramento in vivo utilizando a tecnica de Monte Carlo

VENTURINI, LUZIA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:17Z (GMT). No. of bitstreams: 1 09672.pdf: 6449551 bytes, checksum: fc741e642f1069dc9671f312a9c4532b (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
17

Avaliação das doses resultantes de procedimentos radiodiagnósticos realizados em medicina veterinária e avaliação das doses secundárias de radiação espalhadas no corpo clínico e nos proprietários dos animais / Evaluation of doses from radiodiagnostic procedures performed in veterinary medicine and assessing of the doses of secondary radiation in the medical staff and animal owners

VENEZIANI, GLAUCO R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:49Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
18

Estudo de incertezas no monitoramento in vivo utilizando a tecnica de Monte Carlo

VENTURINI, LUZIA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:49:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:17Z (GMT). No. of bitstreams: 1 09672.pdf: 6449551 bytes, checksum: fc741e642f1069dc9671f312a9c4532b (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
19

Avaliação das doses resultantes de procedimentos radiodiagnósticos realizados em medicina veterinária e avaliação das doses secundárias de radiação espalhadas no corpo clínico e nos proprietários dos animais / Evaluation of doses from radiodiagnostic procedures performed in veterinary medicine and assessing of the doses of secondary radiation in the medical staff and animal owners

VENEZIANI, GLAUCO R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:49Z (GMT). No. of bitstreams: 0 / O objetivo primordial em radiologia veterinária é a produção de radiografias com qualidade diagnóstica, em uma primeira tentativa. Esse objetivo deve atender a três propósitos: (1) diminuir a exposição à radiação do paciente e trabalhadores; (2) diminuir o custo do estudo para o cliente e (3) produzir dados diagnósticos para rápida interpretação e tratamento do paciente. Esse trabalho teve por objetivo a determinação das doses em cães submetidos a radiografias de tórax e abdômen utilizando a técnica da dosimetria termoluminescente (TL). As doses de radiação foram avaliadas com a utilização de dosímetros termoluminescentes de sulfato de cálcio dopado com disprósio (CaSO4:Dy) e fluoreto de lítio dopado com magnésio e titânio (LiF:Mg,Ti). Os resultados obtidos indicam que é extremamente importante a avaliação das doses de radiação envolvidas em procedimentos diagnósticos de radiologia veterinária, para a avaliação das doses nos animais e para ser usado como um parâmetro para a monitoração individual dos proprietários de animais, que auxiliam no posicionamento, e para a proteção dos trabalhadores ocupacionalmente expostos nas Clínicas de Radiologia Veterinária. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
20

Разработка информационной системы для анализа ключевых показателей эффективности (KPI) персонала в сети филиалов компании «ДПО» : магистерская диссертация / Development of an information system for the analysis of key performance indicators (KPI) of personnel in the network of branches of the company "DPO"

Коломытцева, А. А., Kolomyttseva, A. A. January 2023 (has links)
Актуальность выбранной темы заключается в том, что эффективность персонала является одним из главных факторов успеха любой компании. Однако оценка эффективности персонала может быть трудной задачей, особенно для компаний с большим числом филиалов. Информационная система для анализа KPI персонала позволит компаниям оптовой и розничной торговли более точно оценивать работу своих сотрудников, а также идентифицировать проблемные места и принимать своевременные меры для их устранения. Объектом исследования являются методы оценки результативности работы персонала. Предметом исследования является использование KPI для предприятий оптовой и розничной торговли. Научная новизна данной работы заключается в нахождении алгоритмического, программного и математического решения задачи управления персоналом, позволяющего сократить время на процесс анализа деятельности компании. / The relevance of the chosen topic lies in the fact that the effectiveness of the staff is one of the main success factors of any company. However, evaluating staff performance can be a difficult task, especially for companies with a large number of branches. The information system for personnel KPI analysis will allow wholesale and retail companies to more accurately evaluate the work of their employees, as well as identify problem areas and take timely measures to eliminate them. The object of the study is the methods for assessing the effectiveness of the work of personnel. The subject of the research is the use of KPI for wholesalers and retailers. The scientific novelty of this work lies in finding an algorithmic, software and mathematical solution to the problem of personnel management, which allows to reduce the time for the process of analyzing the company's activities.

Page generated in 0.1212 seconds