• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Análise fotoelástica da distribuição de tensões peri-implantares em overdenture mandibular retida por implante unitário com diferentes tipos de conexão / Photoelastic stress distribution produced by different retention systems for a single-implant mandibular overdenture

Nascimento, João Francisco Machado do 14 August 2013 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2014-09-02T11:26:28Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação Joao Francisco Machado do Nascimento.pdf: 721039 bytes, checksum: 2a145e907cf0cfc7e15f26459ae30aff (MD5) / Made available in DSpace on 2014-09-02T11:26:28Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertação Joao Francisco Machado do Nascimento.pdf: 721039 bytes, checksum: 2a145e907cf0cfc7e15f26459ae30aff (MD5) Previous issue date: 2013-08-14 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / For patients poorly adapted to conventional dentures, the single-implant mandibular overdenture has been proposed as a simplified alternative for the two-implant treatment, together with the use of immediate loading of the implant. The aim of this in vitro study was to compare the photoelastic characteristics of stress transfer to the implant in a single-implant mandibular overdenture using different types of attachments. A photoelastic model of an edentulous mandible with a resilient edentulous ridge and a unique implant located at the symphyseal region was obtained to reproduce a single implant-retained mandibular overdenture. Six 2.0 mm height attachments were selected and inserted in the same photoelastic model in a random order. A universal material testing machine was used to induce axial vertical loads of 70 N applied in the central incisor and in the central region of the first right molar without contact on the contralateral side. The photoelastic analysis was performed using a polariscope integrated into the testing machine. Standard separate views were photographed and evaluated visually for stress-induced fringes, to comparatively rank the different attachment systems. All attachments showed a similar tension distribution concentrated in the apical third, and the highest stress concentration at the apical level. There was a low stress concentration at the coronal third of the implant, with no discernible stress in the first threads of the implants, except for Dalla Bona which showed low stress at the coronal part of the implant (one fringe). No identifiable fringes were observed when the load was applied in the molar region, which resulted from the low amount of stress transmitted by the implant for all attachments. It was concluded that the load transferred to a single mandibular implant is low and within the limits of functional loading, irrespective of the type of retention system. / Implantes osseointegrados vêm sendo utilizados com sucesso para restaurar a função e a estética de pacientes desdentados totais e parciais. No entanto há necessidade de tornar o tratamento de pessoas com necessidade de overdenture retida com implante menos oneroso e mais eficiente. O objetivo deste trabalho foi verificar pela técnica fotoelástica (Qualitativa) as tensões geradas ao redor do implante pela aplicação de carga sobre overdenture mandibular retida por um implante unitário na sínfise da mandibular. Foi confeccionado um modelo de resina fotoelástica Araldite, reproduzido de uma mandibular anatômica, onde foi fixado na região sínfise um implante 3.75x11mm (Titamax Ti Cortical, Neodent, Curitiba, Brasil). Com um modelo foi confeccionada uma prótese total e gingival artificial. Todos os pilares foram posicionados sobre o implante e apertado com 10 Ncm, a fêmea foi capturada de forma direta à prótese, com a réplica da mucosa em posição. Todos foram sucessivamente capturados e levados ‘à máquina de ensaio universal. Com uma carga axial de 70 Ncm na fossa central do 46 e incisal do 41. Foram fotografados em um polariscópio as franjas resultantes das tensões. Foram feitas análises qualitativa dos resultados das tensões sobre o attachment. De acordo com os resultados obtidos pode-se concluir que a carga transferida para o implante, é baixo, independente do sistema de retenção.
2

Avaliação de próteses fixas sobre implantes com diferentes níveis de ajuste pilar/prótese: efeito da ciclagem termomecânica sobre diferentes parafusos protéticos e análise fotoelástica da transmissão de tensões / Evaluation of fixed implant-supported prostheses with different levels of abutment/prosthesis fit: the effect of thermomechanical cycling on different abutment screws and photoelastic analysis of stress transmission

Silva, Rafael Candido Pedroso e 05 June 2012 (has links)
O objetivo deste estudo foi verificar os efeitos da ciclagem termomecânica sobre parafusos protéticos, convencionais de titânio e com cobertura de carbono, usados para fixação de próteses parciais fixas com desajuste de 150µm entre pilar e prótese, utilizando próteses sem desajuste como controle. Após ciclagem termomecânica das próteses, foram verificadas a adaptação marginal, a perda de torque dos parafusos protéticos e análise fotoelástica da distribuição de tensões ao redor dos implantes. Foram confeccionadas 12 próteses fixas sobre implantes, as quais foram divididas inicialmente em dois grupos (n=6): grupo 1 - sem desajuste (controle); grupo 2 - com desajuste simulado de 150μm. Todas as próteses foram avaliadas em relação à adaptação marginal antes e após a simulação de ciclos mastigatórios. Os conjuntos foram submetidos a um total de 2.000.000 de ciclos mastigatórios, sendo que estes ensaios foram feitos duas vezes e os grupos iniciais foram subdivididos, na primeira vez foram utilizados parafusos com cobertura de carbono: grupo 1A (adaptadas) e grupo 2A (desadaptadas) e na segunda vez parafusos de titânio convencionais: grupo 1B (adaptadas) e grupo 2B (desadaptadas). A perda de torque dos parafusos foi analisada antes (T0), após 1.000.000 (T1) e 2.000.000 de ciclos (T2). A adaptação marginal após o ensaio melhorou significativamente ao se utilizar parafusos convencionais nas próteses adaptadas: pré-molar (p=0,001) e molar (p=0,028); e desadaptadas: pré-molar (p=0,014) e molar (p=0,007); mas ao se utilizar parafusos cobertos com carbono, a adaptação melhorou somente no pré-molar (p=0,015) das próteses desadaptadas. Quanto à perda de torque dos parafusos protéticos houve diferenças significantes antes e após a simulação dos ciclos mastigatórios entre as próteses adaptadas e desadaptadas, no molar, em todos os tempos para ambos parafusos (p≤0,05); No pré-molar houve diferença significante apenas para os parafusos cobertos com carbono em T0 (p=0,019) e T2 (p=0,044). Quando comparados os parafusos, nas próteses adaptadas houve diferenças significantes no pré-molar em T1 (p=0,026) e T2 (p=0,043); e no molar em T2 (p=0,032); nas próteses desadaptadas houve diferenças significantes apenas para o pré-molar em T1 (p=0,046). Em relação à análise fotoelástica qualitativa, observou-se que em geral a aplicação de carga (10Kgf) gerou maior concentração e intensidade de tensões nas próteses desadaptadas, quando comparadas às adaptadas. Pode-se concluir que a simulação de ciclos mastigatórios teve influência sobre a adaptação marginal das próteses; em relação a perda de torque houve diferenças estatisticamente significantes entre as próteses adaptadas e desadaptadas; o tratamento de superfície dos parafusos foi eficaz apenas para próteses adaptadas, a análise fotoelástica sugere que próteses com desadaptações marginais provocam maior tensão ao redor dos implantes. / The objective of this study was to investigate the effects of thermomechanical cycling on prosthetic screws, conventional titanium and carbon coated, used for fixation of fixed partial dentures (FDP) with 150μm of misfit between abutment and prosthesis, using fitted prostheses as control. After thermomechanical cycling of prostheses were verified, the marginal fit, the torque loss of prosthetic screws and the photoelastic analysis of stress distribution around implants. Twelve implant-supported fixed partial dentures were prepared and initially divided into two groups (n=6): group 1 - fitted prostheses (control), group 2 - 150μm of simulated misfit. All prostheses had their marginal fit evaluated before and after simulation of cycles. The sets were subjected to a total of 2 million of cycles. Each group was assayed twice: in the first time, carbon coated screws were used: group 1A (fitted) and group 2A (misfitted); and in a second time, conventional titanium screws were used: group 1B (fitted) and group 2B (misfitted). The torque loss of the screws was analyzed before (T0), after 1,000,000 (T1) and 2,000,000 cycles (T2). Marginal fit improved significantly when using conventional screws in fitted prostheses: premolar (p=0,001) and molar (p=0,028), and in misfitted prostheses: premolar (p=0,014) and molar (p=0,007), but when using carbon coated screws, fit improved only in the premolar (p=0,015) of the misfitted prostheses. Torque loss of prosthetic screws were significantly different before and after simulation of the cycles between the fitted and misfitted, in molar, at all times for both screws (p≤0,05); and in the premolar, were significant differences were noted only for the carbon coated screws at T0 (p=0,019) and T2 (p=0,044).When comparing the screws in the fitted prostheses, significant differences were noted in pre-molar at T1 (p=0,026) and T2 (p=0,043), and in the molar at T2 (p=0,032); whereas in the misfitted prostheses, significant difference was noted only for premolar at T1 (p=0,046). It was observed in qualitative photoelastic analysis that the load application (10Kgf) generated higher concentration and intensity of stresses in the misfitted prostheses, when compared to fitted ones. It can be concluded that the simulation of thermomechanical cycles had an influence on marginal fit of the prostheses. In relation to torque loss, differences between fitted and misfitted prostheses were noted, but the surface treatment of screws was effective only for fitted prostheses, and the photoelastic analysis suggests that prostheses with marginal misfit causes more stress around the implants.
3

Avaliação de próteses fixas sobre implantes com diferentes níveis de ajuste pilar/prótese: efeito da ciclagem termomecânica sobre diferentes parafusos protéticos e análise fotoelástica da transmissão de tensões / Evaluation of fixed implant-supported prostheses with different levels of abutment/prosthesis fit: the effect of thermomechanical cycling on different abutment screws and photoelastic analysis of stress transmission

Rafael Candido Pedroso e Silva 05 June 2012 (has links)
O objetivo deste estudo foi verificar os efeitos da ciclagem termomecânica sobre parafusos protéticos, convencionais de titânio e com cobertura de carbono, usados para fixação de próteses parciais fixas com desajuste de 150µm entre pilar e prótese, utilizando próteses sem desajuste como controle. Após ciclagem termomecânica das próteses, foram verificadas a adaptação marginal, a perda de torque dos parafusos protéticos e análise fotoelástica da distribuição de tensões ao redor dos implantes. Foram confeccionadas 12 próteses fixas sobre implantes, as quais foram divididas inicialmente em dois grupos (n=6): grupo 1 - sem desajuste (controle); grupo 2 - com desajuste simulado de 150μm. Todas as próteses foram avaliadas em relação à adaptação marginal antes e após a simulação de ciclos mastigatórios. Os conjuntos foram submetidos a um total de 2.000.000 de ciclos mastigatórios, sendo que estes ensaios foram feitos duas vezes e os grupos iniciais foram subdivididos, na primeira vez foram utilizados parafusos com cobertura de carbono: grupo 1A (adaptadas) e grupo 2A (desadaptadas) e na segunda vez parafusos de titânio convencionais: grupo 1B (adaptadas) e grupo 2B (desadaptadas). A perda de torque dos parafusos foi analisada antes (T0), após 1.000.000 (T1) e 2.000.000 de ciclos (T2). A adaptação marginal após o ensaio melhorou significativamente ao se utilizar parafusos convencionais nas próteses adaptadas: pré-molar (p=0,001) e molar (p=0,028); e desadaptadas: pré-molar (p=0,014) e molar (p=0,007); mas ao se utilizar parafusos cobertos com carbono, a adaptação melhorou somente no pré-molar (p=0,015) das próteses desadaptadas. Quanto à perda de torque dos parafusos protéticos houve diferenças significantes antes e após a simulação dos ciclos mastigatórios entre as próteses adaptadas e desadaptadas, no molar, em todos os tempos para ambos parafusos (p≤0,05); No pré-molar houve diferença significante apenas para os parafusos cobertos com carbono em T0 (p=0,019) e T2 (p=0,044). Quando comparados os parafusos, nas próteses adaptadas houve diferenças significantes no pré-molar em T1 (p=0,026) e T2 (p=0,043); e no molar em T2 (p=0,032); nas próteses desadaptadas houve diferenças significantes apenas para o pré-molar em T1 (p=0,046). Em relação à análise fotoelástica qualitativa, observou-se que em geral a aplicação de carga (10Kgf) gerou maior concentração e intensidade de tensões nas próteses desadaptadas, quando comparadas às adaptadas. Pode-se concluir que a simulação de ciclos mastigatórios teve influência sobre a adaptação marginal das próteses; em relação a perda de torque houve diferenças estatisticamente significantes entre as próteses adaptadas e desadaptadas; o tratamento de superfície dos parafusos foi eficaz apenas para próteses adaptadas, a análise fotoelástica sugere que próteses com desadaptações marginais provocam maior tensão ao redor dos implantes. / The objective of this study was to investigate the effects of thermomechanical cycling on prosthetic screws, conventional titanium and carbon coated, used for fixation of fixed partial dentures (FDP) with 150μm of misfit between abutment and prosthesis, using fitted prostheses as control. After thermomechanical cycling of prostheses were verified, the marginal fit, the torque loss of prosthetic screws and the photoelastic analysis of stress distribution around implants. Twelve implant-supported fixed partial dentures were prepared and initially divided into two groups (n=6): group 1 - fitted prostheses (control), group 2 - 150μm of simulated misfit. All prostheses had their marginal fit evaluated before and after simulation of cycles. The sets were subjected to a total of 2 million of cycles. Each group was assayed twice: in the first time, carbon coated screws were used: group 1A (fitted) and group 2A (misfitted); and in a second time, conventional titanium screws were used: group 1B (fitted) and group 2B (misfitted). The torque loss of the screws was analyzed before (T0), after 1,000,000 (T1) and 2,000,000 cycles (T2). Marginal fit improved significantly when using conventional screws in fitted prostheses: premolar (p=0,001) and molar (p=0,028), and in misfitted prostheses: premolar (p=0,014) and molar (p=0,007), but when using carbon coated screws, fit improved only in the premolar (p=0,015) of the misfitted prostheses. Torque loss of prosthetic screws were significantly different before and after simulation of the cycles between the fitted and misfitted, in molar, at all times for both screws (p≤0,05); and in the premolar, were significant differences were noted only for the carbon coated screws at T0 (p=0,019) and T2 (p=0,044).When comparing the screws in the fitted prostheses, significant differences were noted in pre-molar at T1 (p=0,026) and T2 (p=0,043), and in the molar at T2 (p=0,032); whereas in the misfitted prostheses, significant difference was noted only for premolar at T1 (p=0,046). It was observed in qualitative photoelastic analysis that the load application (10Kgf) generated higher concentration and intensity of stresses in the misfitted prostheses, when compared to fitted ones. It can be concluded that the simulation of thermomechanical cycles had an influence on marginal fit of the prostheses. In relation to torque loss, differences between fitted and misfitted prostheses were noted, but the surface treatment of screws was effective only for fitted prostheses, and the photoelastic analysis suggests that prostheses with marginal misfit causes more stress around the implants.
4

Avaliação fotoelástica de tensões transmitidas por próteses protocolos com barras confeccionadas em diferentes materiais e técnicas / Photoelastic stress analysis of a mandibular implant-supported prosthesis with differrent framework materials

Zaparolli, Danilo 12 December 2014 (has links)
Com o avanço da implantodontia e da estética, novos materiais estão sendo utilizados para substituir partes metálicas de próteses. Este estudo teve como objetivo comparar as tensões geradas por próteses implantossuportadas totais de mandíbula em função da variação do material utilizado nas barras e do modo de confecção, através de análise fotoelástica qualitativa. Em um modelo mestre simulando a curvatura da mandíbula foram posicionados 4 implantes de conexão locking taper. A partir deste planejamento foi confeccionada uma barra por CAD/CAM em resina reforçada por fibra que serviu de base para confecção de outras duas barras por CAD/CAM em Ti e CoCr e outra fundida em CoCr, totalizando quatro barras sobre as quais foram confeccionadas próteses totais padronizadas em resina acrílica. Foi analisada a adaptação marginal por meio de microscópio ótico comparador. O modelo fotoelástico foi confeccionado com base no modelo mestre. O ensaio realizado com cargas em oclusão total contra antagonista, mordida anterior, mordida posterior e pontual no extremo do cantilever. Todas as próteses com barras metálicas transmitiram tensões para região cervical dos implantes sendo que a barra de CoCr usinada apresentou o pior padrão de distribuição de tensões e a fundida a pior adaptação / With the recent advancement of implant dentistry and aesthetics new materials are being used to replace metal frameworks of prostheses. This study aimed to compare the stress distributed by mandibular implant-supported prosthesis due to the variation of materials and production techniques of the prosthesis framework by a qualitative photoelastic analysis. In an acrylic model simulating the mandibular curvature, four implants 4.5mm x 6mm with locking taper conection were positioned. From this planning was made a framework of resin reinforced with fiber by CAD/CAM which served as base for manufacturing the two other frameworks in CAD/CAM of Ti and CoCr and cast of CoCr, totaling four frameworks on which standardized denture acrylic resin were prepared. Marginal adaptation was analyzed by optical microscope comparison. The photoelastic model was made based on the master model. The photoelastic test was performed at loads in total occlusion versus antagonist, anterior bite, posterior bite and punctual at the cantilever All prostheses with metal frameworks transmitted stress forces to the cervical region of the implants, and the machined framework of CoCr (G2) showed the worst pattern of stress distribution, and the cast one showed the poorer adjustment (G4). The framework in fiber reinforced resin showed adequate stress distribution and marginal adaptation
5

Avaliação fotoelástica de tensões transmitidas por próteses protocolos com barras confeccionadas em diferentes materiais e técnicas / Photoelastic stress analysis of a mandibular implant-supported prosthesis with differrent framework materials

Danilo Zaparolli 12 December 2014 (has links)
Com o avanço da implantodontia e da estética, novos materiais estão sendo utilizados para substituir partes metálicas de próteses. Este estudo teve como objetivo comparar as tensões geradas por próteses implantossuportadas totais de mandíbula em função da variação do material utilizado nas barras e do modo de confecção, através de análise fotoelástica qualitativa. Em um modelo mestre simulando a curvatura da mandíbula foram posicionados 4 implantes de conexão locking taper. A partir deste planejamento foi confeccionada uma barra por CAD/CAM em resina reforçada por fibra que serviu de base para confecção de outras duas barras por CAD/CAM em Ti e CoCr e outra fundida em CoCr, totalizando quatro barras sobre as quais foram confeccionadas próteses totais padronizadas em resina acrílica. Foi analisada a adaptação marginal por meio de microscópio ótico comparador. O modelo fotoelástico foi confeccionado com base no modelo mestre. O ensaio realizado com cargas em oclusão total contra antagonista, mordida anterior, mordida posterior e pontual no extremo do cantilever. Todas as próteses com barras metálicas transmitiram tensões para região cervical dos implantes sendo que a barra de CoCr usinada apresentou o pior padrão de distribuição de tensões e a fundida a pior adaptação / With the recent advancement of implant dentistry and aesthetics new materials are being used to replace metal frameworks of prostheses. This study aimed to compare the stress distributed by mandibular implant-supported prosthesis due to the variation of materials and production techniques of the prosthesis framework by a qualitative photoelastic analysis. In an acrylic model simulating the mandibular curvature, four implants 4.5mm x 6mm with locking taper conection were positioned. From this planning was made a framework of resin reinforced with fiber by CAD/CAM which served as base for manufacturing the two other frameworks in CAD/CAM of Ti and CoCr and cast of CoCr, totaling four frameworks on which standardized denture acrylic resin were prepared. Marginal adaptation was analyzed by optical microscope comparison. The photoelastic model was made based on the master model. The photoelastic test was performed at loads in total occlusion versus antagonist, anterior bite, posterior bite and punctual at the cantilever All prostheses with metal frameworks transmitted stress forces to the cervical region of the implants, and the machined framework of CoCr (G2) showed the worst pattern of stress distribution, and the cast one showed the poorer adjustment (G4). The framework in fiber reinforced resin showed adequate stress distribution and marginal adaptation
6

Análise fotoelástica das tensões geradas por coroas unitárias sobre implantes adjacentes na região posterior da mandíbula. Efeito de sistemas de retenção e materiais de revestimento estético / Photoelastic analysis of stress generated by singlecrowns over adjacent implants in the posterior mandible. Effect of retention systems and veneering materials

Aguiar Junior, Fábio Afrânio de 22 January 2010 (has links)
Implantes osseointegrados vêm sendo utilizados com sucesso para restaurar a função e a estética de pacientes desdentados totais e parciais, no entanto, apesar do alto índice de sucesso, a literatura apresenta uma série de complicações da técnica. Apesar da falta de consenso sobre qual a melhor maneira de se restaurar implantes múltiplos adjacentes, a confecção de próteses unitárias vem sendo sugerida e praticada por muitos profissionais. O objetivo deste trabalho foi verificar, pela técnica fotoelástica (qualitativa e quantitativa), o comportamento biomecânico de coroas unitárias sobre implantes hexágono interno com pilar UCLA. Foram confeccionadas coroas cimentadas e parafusadas, simulando a reabilitação da área posterior da mandíbula com e sem a presença de elemento dental distal aos implantes. Foram analisados, também, a liga metálica da infraestrutura (Ni-Cr-Ti ou Ni-Cr) e o tipo de material para revestimento estético (cerâmica ou resina). Foram confeccionados modelos fotoelásticos simulando espaço protético com ausência de segundo pré-molar e primeiro molar, reabilitado com coroas sobre implantes. Três modelos de pontas de aplicação de carga foram utilizados para produzir quatro diferentes condições de carregamento na superfície oclusal das coroas: 1 -puntiforme obtido com uma ponta simples para carregamento no pré-molar ou no molar com 5kgf; 2 puntiforme simultânea obtido por uma ponta dupla para carregamento das duas coroas ao mesmo tempo com 10kgf; 3 - oclusal distribuído obtido com uma ponta que simulou a oclusão antagonista com 10kgf. Após a aplicação das cargas, foram obtidos registros fotográficos para análise qualitativa e posteriormente foi realizada a análise quantitativa em três pontos na região cervical e um ponto na região apical de cada implante. De acordo com os resultados obtidos pode-se concluir que o uso de ligas de Ni-Cr-Ti ou Ni-Cr não interferiu na transmissão de tensões. Coroas revestidas em resina, de modo geral, geraram maior concentração de tensões em torno dos implantes quando comparadas às coroas revestidas em cerâmica. As coroas parafusadas provocaram maior tensão em torno dos implantes quando comparadas às coroas cimentadas. A presença do dente com ponto de contato efetivo à distal das coroas sobre implantes favoreceu a distribuição de tensões. / Osseointegrated implants have been successfully used to restore function and esthetic to fully and partially edentulous patients; however, regardless of the high success, the literature reveals some complications of the technique. Despite the lack of consensus about what is the better way to restore multiple adjacent implants, the use of single crowns have been suggested and practiced by many professionals. The purpose of the present study was to verify, using photoelastic analysis (qualitative and quantitative), the biomechanical behavior of single crowns on internal hexagon implants with UCLA abutment. Cement and screw-retained crowns was fabricated simulating the rehabilitation of posterior mandible area with or without the presence of a dental element distal to the implants. The metal framework alloys (Ni-Cr-Ti or Ni- Cr) and the esthetic veneering materials (ceramic or resin) was, also, analyzed. Photoelastic models were made simulating the missing of the second pre-molar and the first molar, rehabilitated with implant-supported crowns. Three models of loading application tips were used to produce different conditions of loading on crowns occlusal surface: 1 punctiform obtained with a simple tip for loading over premolar or molar with 5 Kgf; 2 simultaneous punctiform obtained with a Double tip for loading over both crowns in the same time with 10 Kgf; 3 distributed occlusal obtained with a tip simulating the antagonist occlusion with 10 Kgf. After loading application photographic records were obtained for qualitative analysis, and in sequence, quantitative analysis was realized in three cervical points and one point in the apical area of each implant. According to the obtained results, it was concluded that the use of Ni-Cr-Ti or Ni-Cr alloys did not interfere in stress transmission. Resin veneered crowns, generally generated higher concentration of stress around the implants when compared to ceramic veneered crowns. Screw-retained crowns promoted higher stress around the implants when compared to cement-retained crowns. The presence of teeth with effective interproximal contact distal to implantsupported crowns improved the stress distribution.
7

Análise fotoelástica das tensões geradas por coroas unitárias sobre implantes adjacentes na região posterior da mandíbula. Efeito de sistemas de retenção e materiais de revestimento estético / Photoelastic analysis of stress generated by singlecrowns over adjacent implants in the posterior mandible. Effect of retention systems and veneering materials

Fábio Afrânio de Aguiar Junior 22 January 2010 (has links)
Implantes osseointegrados vêm sendo utilizados com sucesso para restaurar a função e a estética de pacientes desdentados totais e parciais, no entanto, apesar do alto índice de sucesso, a literatura apresenta uma série de complicações da técnica. Apesar da falta de consenso sobre qual a melhor maneira de se restaurar implantes múltiplos adjacentes, a confecção de próteses unitárias vem sendo sugerida e praticada por muitos profissionais. O objetivo deste trabalho foi verificar, pela técnica fotoelástica (qualitativa e quantitativa), o comportamento biomecânico de coroas unitárias sobre implantes hexágono interno com pilar UCLA. Foram confeccionadas coroas cimentadas e parafusadas, simulando a reabilitação da área posterior da mandíbula com e sem a presença de elemento dental distal aos implantes. Foram analisados, também, a liga metálica da infraestrutura (Ni-Cr-Ti ou Ni-Cr) e o tipo de material para revestimento estético (cerâmica ou resina). Foram confeccionados modelos fotoelásticos simulando espaço protético com ausência de segundo pré-molar e primeiro molar, reabilitado com coroas sobre implantes. Três modelos de pontas de aplicação de carga foram utilizados para produzir quatro diferentes condições de carregamento na superfície oclusal das coroas: 1 -puntiforme obtido com uma ponta simples para carregamento no pré-molar ou no molar com 5kgf; 2 puntiforme simultânea obtido por uma ponta dupla para carregamento das duas coroas ao mesmo tempo com 10kgf; 3 - oclusal distribuído obtido com uma ponta que simulou a oclusão antagonista com 10kgf. Após a aplicação das cargas, foram obtidos registros fotográficos para análise qualitativa e posteriormente foi realizada a análise quantitativa em três pontos na região cervical e um ponto na região apical de cada implante. De acordo com os resultados obtidos pode-se concluir que o uso de ligas de Ni-Cr-Ti ou Ni-Cr não interferiu na transmissão de tensões. Coroas revestidas em resina, de modo geral, geraram maior concentração de tensões em torno dos implantes quando comparadas às coroas revestidas em cerâmica. As coroas parafusadas provocaram maior tensão em torno dos implantes quando comparadas às coroas cimentadas. A presença do dente com ponto de contato efetivo à distal das coroas sobre implantes favoreceu a distribuição de tensões. / Osseointegrated implants have been successfully used to restore function and esthetic to fully and partially edentulous patients; however, regardless of the high success, the literature reveals some complications of the technique. Despite the lack of consensus about what is the better way to restore multiple adjacent implants, the use of single crowns have been suggested and practiced by many professionals. The purpose of the present study was to verify, using photoelastic analysis (qualitative and quantitative), the biomechanical behavior of single crowns on internal hexagon implants with UCLA abutment. Cement and screw-retained crowns was fabricated simulating the rehabilitation of posterior mandible area with or without the presence of a dental element distal to the implants. The metal framework alloys (Ni-Cr-Ti or Ni- Cr) and the esthetic veneering materials (ceramic or resin) was, also, analyzed. Photoelastic models were made simulating the missing of the second pre-molar and the first molar, rehabilitated with implant-supported crowns. Three models of loading application tips were used to produce different conditions of loading on crowns occlusal surface: 1 punctiform obtained with a simple tip for loading over premolar or molar with 5 Kgf; 2 simultaneous punctiform obtained with a Double tip for loading over both crowns in the same time with 10 Kgf; 3 distributed occlusal obtained with a tip simulating the antagonist occlusion with 10 Kgf. After loading application photographic records were obtained for qualitative analysis, and in sequence, quantitative analysis was realized in three cervical points and one point in the apical area of each implant. According to the obtained results, it was concluded that the use of Ni-Cr-Ti or Ni-Cr alloys did not interfere in stress transmission. Resin veneered crowns, generally generated higher concentration of stress around the implants when compared to ceramic veneered crowns. Screw-retained crowns promoted higher stress around the implants when compared to cement-retained crowns. The presence of teeth with effective interproximal contact distal to implantsupported crowns improved the stress distribution.

Page generated in 0.094 seconds