• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 51
  • 30
  • 21
  • 4
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 117
  • 117
  • 66
  • 46
  • 33
  • 31
  • 30
  • 26
  • 25
  • 24
  • 19
  • 17
  • 16
  • 15
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Desempenho de sistemas de condicionamento de ar com utilização de energia solar em edifícios de escritórios. / Performance of solar air conditioning systems in office buildings.

Ara, Paulo José Schiavon 14 December 2010 (has links)
A preocupação energética tem impulsionado a humanidade a buscar alternativas sustentáveis de energia. Neste contexto, os edifícios de escritórios têm um papel importante, em especial, devido ao elevado consumo de energia dos sistemas de condicionamento de ar. Para esses sistemas, a possibilidade de utilização de energia solar é uma alternativa tecnicamente possível e interessante de ser considerada, principalmente porque, quando a carga térmica do edifício é mais elevada, a radiação solar também é mais elevada. Dentre os sistemas de condicionamento de ar solar, o sistema térmico - que associa coletores solares térmicos com chiller de absorção - é o mais disseminado, na atualidade. Entretanto, dependendo do caso, outras tecnologias podem ser vantajosas. Uma opção, por exemplo, no caso de edifícios de escritórios, é o sistema elétrico - que associa painéis fotovoltaicos ao chiller convencional de compressão de vapor. Neste trabalho, para um edifício de escritórios de 20 pavimentos e 1000 m2 por pavimento, na cidade de São Paulo, no Brasil, duas alternativas de ar condicionado solar tiveram seus desempenhos energéticos analisados: o sistema térmico - com coletores solares térmicos somente na cobertura e o sistema elétrico - com painéis FV somente nas superfícies opacas das fachadas. Para isso, com o software EnergyPlus do Departamento de Energia dos Estados Unidos obteve-se as carga térmica atuantes no edifício e com a aplicação do método de cálculo de consumo de energia dos sistemas de ar condicionado solar, proposto pelo Projeto SOLAIR da União Européia, adaptado para a realidade da pesquisa, obteve-se o desempenho energético dos sistemas. Os resultados mostraram que, para o edifício de 20 pavimentos, o sistema elétrico tem o melhor desempenho energético, economizando 28% e 71% da energia elétrica que consumiria um sistema de ar condicionado convencional, em um dia de verão e de inverno, respectivamente. O sistema térmico, ao contrário, apresentou um desempenho energético ruim para o edifício estudado, consumindo, por exemplo, em um dia de verão, cerca de 4 vezes mais energia elétrica do que um sistema de ar condicionado convencional. Constatouse que isso ocorreu, pois a área coletora limitada à cobertura foi insuficiente para atender a demanda do chiller de absorção, que passou a operar com frações solares baixas, da ordem de 50% e 20%, de pico, no dia de inverno e de verão, respectivamente. Assim, constatou-se que para que o sistema térmico apresente um desempenho energético satisfatório é preciso que o edifício não seja tão alto. De fato, os resultados mostraram que somente se o edifício tivesse no máximo 2 pavimentos, o sistema térmico teria um desempenho energético melhor do que um sistema convencional. No caso de ser aplicado ao edifício térreo de 1000m2 de área, por exemplo, esse sistema economizaria aproximadamente 65% da energia elétrica do sistema convencional. Por fim, constatou-se também que o desempenho energético do sistema térmico seria elevado com a otimização da área e da tecnologia de coletores solares, com o aprimoramento do sistema de aquecimento auxiliar e com a redução da carga térmica do edifício por meio de técnicas passivas de climatização. / Energy concern has driven human kind to seek sustainable energy alternatives. In this context, office buildings have an important role, especially due to the high energy consumption of air conditioning systems. For these systems, the possibility of using solar energy is technically feasible and interesting to be considered, mainly because generally when the building thermal load is higher, the solar radiation is also higher. Among solar airconditioning systems, the thermal system - which combines solar collectors with absorption chiller - is the most widespread, nowadays. However, depending on the case, other technologies may take advantage. One option, for example, in the case of office buildings, is the electrical system - which combines photovoltaic panels with conventional vapor compression chiller. In this work, an office building of 20 floors with 1,000 m2 floor area, in Sao Paulo, Brazil, two technologies of solar air conditioning had their performance analyzed: the thermal system - presenting solar thermal collectors only on the roof and the electrical system with PV panels only on the opaque surfaces of the facades. For this, the software EnergyPlus of the United States Department of Energy obtained the building thermal load and the with the solar air conditioning energy consumption calculating method proposed by SOLAIR project of the European Union and adapted to this work, energy performance of systems was obtained. The results showed that for this building, the electrical system had the best energy performance, saving 28% and 71% of electricity that would consume a conventional air conditioning system in a summer day and a winter day, respectively. The thermal system, in contrast, showed a poor energy performance, consuming, for example, on a summer day, about four times more electricity than a conventional air conditioning system. It was found that this occurred because the collectors area limited to the roof of the building was insufficient to meet the absorption chiller demand, causing low solar fractions in the operation, of around 50% and 20% peak, in a winter day and in a summer day, respectively. Thus, in order of provide a satisfactory energy performance, the thermal system requires that the building not to be so tall. In fact, the results showed that only if the building had up to two floors, the system would perform better than a conventional system. In case of be installed in a building with the ground floor only, and floor area of 1000m2, for example, this system would save about 65% of the electricity comparing to a conventional system. Finally, it was found that this energy performance would be elevated as well with the optimization of solar collectors area and technology, with auxiliary heating system improvement and with the reduction of thermal load of the building by means of passive air conditioning techniques.
82

Modelos de programação matemática para o gerenciamento de energia em modernos sistemas de distribuição de energia elétrica / Models of mathematical programming for energy management in modern electricity distribution systems

Ñahuis, Fernando Vladimir Cerna [UNESP] 17 February 2017 (has links)
Submitted by FERNANDO VLADIMIR CERNA ÑAHUIS null (fvcerna83@gmail.com) on 2017-02-22T17:36:35Z No. of bitstreams: 1 TESE-FINAL.pdf: 2994686 bytes, checksum: 5e487b40d4aeb0006f40a0abdb9d9af6 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-02-24T20:11:29Z (GMT) No. of bitstreams: 1 nahuis_fvc_dr_ilha.pdf: 2994686 bytes, checksum: 5e487b40d4aeb0006f40a0abdb9d9af6 (MD5) / Made available in DSpace on 2017-02-24T20:11:29Z (GMT). No. of bitstreams: 1 nahuis_fvc_dr_ilha.pdf: 2994686 bytes, checksum: 5e487b40d4aeb0006f40a0abdb9d9af6 (MD5) Previous issue date: 2017-02-17 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Nesta tese são apresentados três modelos de programação matemática que abordam os problemas de otimização relacionados ao gerenciamento da energia nos sistemas de distribuição de energia elétrica (SDEE), como: 1) Programação ótima das entregas e carregamento dos veículos elétricos (VEs) durante a navegação em um mapa de cidade, 2) Gerenciamento ótimo pelo lado da demanda considerando um sistema fotovoltaico híbrido (SFH) em uma residência em baixa tensão (RBT) no SDEE, e 3) O melhoramento do fator de carga (FC) do SDEE através do controle da demanda. O primeiro problema visa minimizar os custos relacionados com a manutenção e geração de horas extra durante a operação de uma frota de VEs, levando em conta um conjunto de entregas pre-especificadas, assim como, pontos de carregamento alocados ao longo de cada via urbana (principal e/ou secundária) pertencente ao mapa da cidade. No segundo problema, para uma residência em baixa tensão é planejado um perfil ótimo de consumo para o dia seguinte. Este perfil de consumo é obtido através de um programa de gerenciamento pelo lado da demanda (GLD) que considera uma estrutura tarifária e um esquema de operação que otimiza os recursos energéticos vindos de um SFH e o SDEE. Para cada problema de otimização é apresentado o seu correspondente modelo de programação não linear inteiro misto (PNLIM). O terceiro problema visa minimizar os custos por compra de energia (consumo e perdas de potência ativa) da concessionária, levando em conta, o controle da demanda dos usos-finais, presentes nas unidades consumidoras (residenciais, comerciais, e industriais) no SDEE. As incertezas na utilização dos usos-finais nas unidades consumidoras são simuladas através de um algoritmo Monte Carlo. Além disso, o modelo proposto PIMRQ é rodado dentro de um processo iterativo, que visa a melhoria do FC do SDEE. Por outro lado, através destes modelos não-lineares, a solução ótima global não é garantida, enquanto o uso de modelos equivalentes (para o primeiro e segundo problema, sendo um modelo aproximado para o terceiro) de programação linear inteira mista (PLIM) resolvidos por ferramentas de otimização clássica existentes garantem a convergência para a solução ótima global. Por conseguinte, para resolver este inconveniente, os seus modelos MILP equivalentes são obtidos e explicados em detalhe. Os modelos propostos foram implementados na linguagem de modelagem algébrica AMPL e resolvidos usando o solver comercial CPLEX. Além disso, algoritmos de simulação para representar as incertezas dos tempos de demora na operação dos VEs e os hábitos de utilização dos usos-finais durante o dia, são desenvolvidos. Um grafo unidirecional de 71 nós, uma rede elétrica IEEE de 34 nós, e 21 usos-finais (incluído um VE plug-in para o carregamento na residência) residenciais são utilizados para testar a precisão e a eficiência, assim como, também técnica de solução dos modelos propostos para cada problema. / This thesis presents three mathematical programming models to address the optimization problems related to the energy management in the electricity distribution systems (EDSs), such as: 1) Optimal delivery scheduling and charging of electric vehicles (EVs) in the navigation of a city map, 2) Optimal demand side management of an EDS considering a hybrid photovoltaic system (HPS) in a residential low voltage (RLV), and 3) Load factor improvement through the demand control in the EDS. The first problem aims at minimizing the costs related to the maintenance and generation of extra hours during the operation of a EVs fleet, taking into account a number of prespecified deliveries, as well as charging points allocated along each urban road (main or secondary) belongs to the city map. In the second problem, for a RLV, an optimal consumption profile of a day-ahead is planned. This consumption profile is obtained through a demand side management (DSM) program that considers a tariff structure and an operating scheme that optimizes the energy resources coming from HFS and EDS. The third problem aims at minimizing the costs of energy purchase (consumption and active energy losses) of the company, taking into account, the demand control of the end-uses, presents in the consumers units (residential, commercial, and industrial) in the EDS. Uncertainties in the use of the end-uses in the different consumer units are simulated through a Monte Carlo algorithm that determines a habitual consumption profile for EDSs. Based on this habitual profile, the proposed MIPRQ model determines an optimal profile for EDSs. This model uses an iterative process that aims to improve the load factor of the EDS. For each optimization problem the corresponding non-linear mixed integer programming (NLMIP) model is presented. On the other hand, via these nonlinear models, the global optimal solution is not guaranteed, while using the equivalent mixed-integer linear (MILP) models (for the first and second problems, being an approximate model for the third) and solving them by existing classical optimization tools ensures convergence to global optimal solution. Therefore, in order to address this drawback, their equivalent mixed integer linear programming (MILP) models are obtained and explained in detail. The proposed models are implemented in the algebraic modeling language AMPL and solved using the commercial CPLEX solver. Moreover, simulations algorithms to represent the uncertainties of delay times in the operation of EVs and usage habits of end-uses during the day, are developed. A multidirectional graph with 71 nodes, an electrical network IEEE 34 nodes, and a quantity of 21 residential end-uses (including an EV plug-in for residential charging) are used to test the precision and the efficiency, as well as the solution technique of the models proposed for each problem. / CNPq: 141462/2013- 2
83

Projeto inversol - desenvolvimento de uma fonte ininterrupta de energia com possibilidade de uso em sistema fotovoltaico / INVERSOL â DEVELOPMENT OF UNINTERRUPTIBLE POWER SUPLLY TO BE USED IN A PHOTOVOLTAIC SYSTEM

Lucas Maciel Menezes 10 April 2007 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / O estudo para o desenvolvimento de uma fonte ininterrupta de energia com possibilidade de uso em sistema fotovoltaico, tem como motivaÃÃo que a larga escala da produÃÃo desse tipo de equipamento possa reduzir o custo dos conversores de eletrÃnica de potÃncia associados a uma instalaÃÃo fotovoltaica. O projeto proporem a uniÃo de topologias de conversores, resultando em uma UPS do tipo on-line com tensÃo de entrada e de saÃda de 220 Volts 60 Hz, potÃncia total de 715VA, rendimento de 88%, isolada em alta freqÃÃncia e com correÃÃo do fator de potÃncia na entrada. Sendo composta por um retificador na entrada com topologia de um conversor em ponte completa alimentado em corrente, esse conversor à responsÃvel por prover a correÃÃo do fator de potÃncia na entrada e da isolaÃÃo galvÃnica em alta freqÃÃncia. Um inversor em ponte completa com filtro LC e modulaÃÃo PWM unipolar, que à capaz de entregar uma tensÃo senoidal para a carga e um conversor boost de alto ganho que cumpre o papel de elevar a tensÃo de 24 Volts do banco de baterias para a tensÃo de 400 Volts do barramento de entrada do inversor. Cada conversor tem seu estudo teÃrico desenvolvido e ao final apÃs as especificaÃÃes e dimensionamentos sÃo mostrados os resultados experimentais do protÃtipo do projeto. Quando o sistema for aproveitado em uma instalaÃÃo fotovoltaica somente o inversor e o conversor boost de alto ganho sÃo utilizados. / The study of the development of initerruptible power supply to be used in a photovoltaic system has as motivation that the wide UPS production scale can reduce the cost of power electronics converters associated with a photovoltaic system. The project proposes a topology of an on-line UPS, with 220 Volts, 60 Hz input/output voltage, 715 VA power, 88% efficiency, High frequency isolation and Power factor correction. The Project consists on a rectifier, it is responsible for providing the input power factor correction and the high frequency isolation. An inverter, it supply the load with a output sinusoidal voltage and a high gain boost converter that increase the voltage from the battery pack up to the inverter. When the project is used in a photovoltaic system, it is only used the inverter and the high gain boost converter.
84

Energy Analysis within Industrial Hydraulics and Correspondent Solar PV System Design

Absalyamova, Viktoriya January 2010 (has links)
Energy efficiency and renewable energy use are two main priorities leading to industrial sustainability nowadays according to European Steel Technology Platform (ESTP). Modernization efforts can be done by industries to improve energy consumptions of the production lines. These days, steel making industrial applications are energy and emission intensive. It was estimated that over the past years, energy consumption and corresponding CO2 generation has increased steadily reaching approximately 338.15 parts per million in august 2010 [1]. These kinds of facts and statistics have introduced a lot of room for improvement in energy efficiency for industrial applications through modernization and use of renewable energy sources such as solar Photovoltaic Systems (PV).The purpose of this thesis work is to make a preliminary design and simulation of the solar photovoltaic system which would attempt to cover the energy demand of the initial part of the pickling line hydraulic system at the SSAB steel plant. For this purpose, the energy consumptions of this hydraulic system would be studied and evaluated and a general analysis of the hydraulic and control components performance would be done which would yield a proper set of guidelines contributing towards future energy savings. The results of the energy efficiency analysis showed that the initial part of the pickling line hydraulic system worked with a low efficiency of 3.3%. Results of general analysis showed that hydraulic accumulators of 650 liter size should be used by the initial part pickling line system in combination with a one pump delivery of 100 l/min. Based on this, one PV system can deliver energy to an AC motor-pump set covering 17.6% of total energy and another PV system can supply a DC hydraulic pump substituting 26.7% of the demand. The first system used 290 m2 area of the roof and was sized as 40 kWp, the second used 109 m2 and was sized as 15.2 kWp. It was concluded that the reason for the low efficiency was the oversized design of the system. Incremental modernization efforts could help to improve the hydraulic system energy efficiency and make the design of the solar photovoltaic system realistically possible. Two types of PV systems where analyzed in the thesis work. A method was found calculating the load simulation sequence based on the energy efficiency studies to help in the PV system simulations. Hydraulic accumulators integrated into the pickling line worked as energy storage when being charged by the PV system as well.
85

Análise de impactos de um sistema fotovoltaico conectado à rede em Mossoró/RN / Analysis of the Impacts of grid-connected photovoltaic system in Mossoró/RN

Balbino, Isaú Macêdo 29 August 2017 (has links)
Submitted by Lara Oliveira (lara@ufersa.edu.br) on 2018-01-17T21:17:50Z No. of bitstreams: 1 IsaúMB_DISSERT.pdf: 2720241 bytes, checksum: 6f834d2d4c55c17ad70d6fca472fbb7a (MD5) / Approved for entry into archive by Vanessa Christiane (referencia@ufersa.edu.br) on 2018-02-20T14:29:04Z (GMT) No. of bitstreams: 1 IsaúMB_DISSERT.pdf: 2720241 bytes, checksum: 6f834d2d4c55c17ad70d6fca472fbb7a (MD5) / Approved for entry into archive by Vanessa Christiane (referencia@ufersa.edu.br) on 2018-02-20T14:31:25Z (GMT) No. of bitstreams: 1 IsaúMB_DISSERT.pdf: 2720241 bytes, checksum: 6f834d2d4c55c17ad70d6fca472fbb7a (MD5) / Made available in DSpace on 2018-02-20T14:31:33Z (GMT). No. of bitstreams: 1 IsaúMB_DISSERT.pdf: 2720241 bytes, checksum: 6f834d2d4c55c17ad70d6fca472fbb7a (MD5) Previous issue date: 2017-08-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Environmental problems, like global warming and pollution, together with the rising fossil fuels prices in recent years have increased search for alternative energy sources, that are clean and sustainable at the same time. Among the main sources, it is possible to highlight the photovoltaic solar energy. For being a source of clean renewable energy with a low maintenance rate, photovoltaic solar energy has been gaining attention worldwide, and with this the Grid-Connected Photovoltaic System (GCPV) has grown in the last decades. Despite the benefits from the GCPV, for being a relatively new technology when compared with other energy sources, the same is not yet fully consolidated, and its installation requires care in regard to quality of electrical power. Problems such as production of harmonics, overvoltage and low power factor are common to these types of systems. Several researches are conducted every year and regulations are created, in order to reconcile the photovoltaic generation with the power distribution network. Therefore, the present work aims to identify, measure and analyze the behavior of GCPV of 3 kWp of UFERSA, in the city of Mossoró-RN, in order to verify the possible impacts to the quality of the electric energy associated with GCPV. In this research it was noticed that all the parameters are within the current standard regulations, however the high indexes of harmonic distortion rate made necessary the elaboration of a low-pass filter to attenuate the unwanted frequencies. With the simulation of the filter in Simulink, an attenuation of up to more than 60% was verified, thus improving the quality of the energy generated by the system / Os problemas ambientais, como o aquecimento global e a poluição, juntamente com o crescente preço dos combustíveis fósseis nos últimos anos, elevaram a procura por fontes alternativas de energia, que ao mesmo tempo fossem limpas e sustentáveis. Dentre as principais fontes, pode-se destacar a energia solar fotovoltaica. Por ser uma fonte de energia limpa, renovável e com baixo índice de manutenção, a energia solar fotovoltaica vem ganhando destaque no mundo inteiro, e com isso os Sistemas Fotovoltaicos Conectados à Rede (SFCR) cresceu nas últimas décadas. Apesar dos benefícios oriundos dos SFCR, por ser uma tecnologia relativamente nova quando comparada com outras fontes de energia, a mesma ainda não está totalmente consolidada, e sua instalação requer cuidados no que diz respeito à qualidade de energia elétrica. Problemas como produção de harmônicos, sobretensão e baixo fator de potência são comuns a estes tipos de sistemas. Várias pesquisas são realizadas todos os anos, e normas e regulamentos são criados, a fim de conciliar a geração fotovoltaica com a rede elétrica de distribuição. Portanto, o presente trabalho tem como objetivo identificar, medir e analisar o comportamento do SFCR de 3 kWp da UFERSA, na cidade de Mossoró-RN, a fim de se verificar os possíveis impactos à qualidade da energia elétrica associados aos SFCR’s. Nesta pesquisa percebeu-se que todos os parâmetros estão dentro das normas vigentes, porém os altos índices de taxa de distorção harmônica fizeram necessário a elaboração de um filtro passa-baixa para atenuar as frequências indesejadas. Com a simulação do filtro no Simulink, constatou-se uma atenuação de até mais de 60%, melhorando assim a qualidade da energia gerada pelo sistema / 2018-01-17
86

Modelos de programação matemática para o gerenciamento de energia em modernos sistemas de distribuição de energia elétrica /

Ñahuis, Fernando Vladimir Cerna. January 2017 (has links)
Orientador: Marcos Júlio Rider Flores / Resumo: Nesta tese são apresentados três modelos de programação matemática que abordam os problemas de otimização relacionados ao gerenciamento da energia nos sistemas de distribuição de energia elétrica (SDEE), como: 1) Programação ótima das entregas e carregamento dos veículos elétricos (VEs) durante a navegação em um mapa de cidade, 2) Gerenciamento ótimo pelo lado da demanda considerando um sistema fotovoltaico híbrido (SFH) em uma residência em baixa tensão (RBT) no SDEE, e 3) O melhoramento do fator de carga (FC) do SDEE através do controle da demanda. O primeiro problema visa minimizar os custos relacionados com a manutenção e geração de horas extra durante a operação de uma frota de VEs, levando em conta um conjunto de entregas pre-especificadas, assim como, pontos de carregamento alocados ao longo de cada via urbana (principal e/ou secundária) pertencente ao mapa da cidade. No segundo problema, para uma residência em baixa tensão é planejado um perfil ótimo de consumo para o dia seguinte. Este perfil de consumo é obtido através de um programa de gerenciamento pelo lado da demanda (GLD) que considera uma estrutura tarifária e um esquema de operação que otimiza os recursos energéticos vindos de um SFH e o SDEE. Para cada problema de otimização é apresentado o seu correspondente modelo de programação não linear inteiro misto (PNLIM). O terceiro problema visa minimizar os custos por compra de energia (consumo e perdas de potência ativa) da concessionária, levando em conta, o co... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
87

Modelagem, análise e experimentação de sistema fotovoltaico isolado baseado em plataforma de simulação com diagrama de blocos.

Santos Junior, Francisco Antonio Ferreira dos 29 February 2016 (has links)
Submitted by Morgana Silva (morgana_linhares@yahoo.com.br) on 2016-07-26T18:10:50Z No. of bitstreams: 1 arquivototal.pdf: 2752063 bytes, checksum: 886fc73f7f66099f1e033937798f6b7e (MD5) / Made available in DSpace on 2016-07-26T18:10:50Z (GMT). No. of bitstreams: 1 arquivototal.pdf: 2752063 bytes, checksum: 886fc73f7f66099f1e033937798f6b7e (MD5) Previous issue date: 2016-02-29 / This paper presents a block diagram modeling of a grid-independent photovoltaic power generation system, including the steps of DC regulation, voltage inversion, and control system based on dynamic simulations in Simulink / Matlab® exclusively using the built-in blocks available in its library. A well-known technique in literature called MPPT (maximum power point tracking) was used for tracking the maximum power of the photovoltaic generation. However, the control that was used to maintain a constant output voltage of the Push-Pull is based on a method that is similar to the MPPT, which configures a novelty of this research. The integration of modeling the entire PV system with these control systems is carried out in Simulink for investigaton and production of simulation results. An experimental platform that includes an emulator of photovoltaic panels, a 1 kW Push-Pull converter, a three-phase inverter with three arms and a hydraulic load constituided by a motor-pump was built in the laboratory. The experimental results corroborate the methodology that was used. / Este trabalho apresenta uma modelagem em diagramação de blocos de um sistema de geração de energia fotovoltaico isolado, incluindo as etapas de regulação CC, inversão de tensão e sistema de controle com base em simulações dinâmicas no ambiente Simulink/Matlab® utilizando, exclusivamente, os blocos built-in disponíveis em sua biblioteca. Uma técnica bem conhecida na literatura foi utilizada para o rastreio da máxima potência da geração fotovoltaica. No entanto, o controle utilizado para manter a tensão de saída constante do Push-Pull é baseado num método similar ao do rastreio da máxima potência, o que configura uma novidade deste trabalho. A integração da modelagem de todo o sistema fotovoltaico com estes sistemas de controle é realizada no ambiente Simulink para averiguação e produção dos resultados de simulação. Uma plataforma experimental que inclui um emulador de painéis fotovoltaicos, um Push-Pull de 1 kW de potência, um inversor trifásico de três braços e uma carga hidráulica constituída por um motobomba foi construída em laboratório. Os resultados experimentais corroboram a metodologia utilizada.
88

Modelagem matemática e implementação computacional no ATP de um sistema solar fotovoltaico conectado a rede de baixa tensão / Mathematical modeling and computational implementation in ATP of photovoltaic solar system connected to low voltage power grid

Cunha, Guilherme Henrique Bernardes 29 July 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The increased demand for energy, the possibility of reducing the supply of conventional fuels and growing concerns about the preservation of the environment have led to several researches and development of alternative energy sources which are clean, renewable and with minor environmental impact. Among the various alternative energy sources, PV solar has been considered an excellent option as it is free, abundant, clean and distributed through all places. Solar energy incident on Earth\'s surface is estimated at about ten thousand times the total energy consumed in the world. Even with all the advantages offered by the generation of energy through the use of photovoltaic panels, the initial cost of deployment is high and the efficiency of energy conversion is currently still low. Thus, it is essential to use techniques to extract the maximum power from these panels to increase the system operation efficiency. This work aims to present studies of a complete photovoltaic solar system, connected to low voltage power grid including the solar panel, a step-up voltage converter, its corresponding Maximum Power Point Tracking (MPPT) control, the voltage inverter with its control, the phase locked loop, and by means of an inductive coupling, the connection of the whole system to the grid. For modeling and simulations of the solar photovoltaic system, it was used the Alternative Transients Program - ATP. Initially it is presented simulation results with parts that comprises the PV array, and only at the end, it is performed a case study with the complete PV system developed in this work. / O aumento da demanda de energia, a possibilidade de redução do suprimento de combustíveis convencionais e a crescente preocupação com a preservação do meio ambiente têm levado a várias pesquisas e desenvolvimento de fontes alternativas de energia que sejam limpas, renováveis e com menor impacto ambiental. Dentre as diversas fontes alternativas de energia, a solar fotovoltaica tem sido considerada uma excelente opção já que é livre, abundante, limpa e distribuída. A energia solar incidente na superfície da Terra é estimada em cerca de dez mil vezes a energia total consumida no mundo. Mesmo com todas as vantagens apresentadas pela geração de energia por meio do uso de painéis fotovoltaicos, a eficiência da conversão de energia é atualmente ainda baixa e com custo inicial de implantação elevado. Assim, é imprescindível o uso de técnicas para extração da máxima potência destes painéis para aumentar a eficiência de operação do sistema. Este trabalho visa apresentar estudos de um sistema fotovoltaico completo conectado à rede elétrica de baixa tensão, compreendendo o painel solar, um conversor elevador de tensão, seu correspondente controle de rastreamento de máxima potência, o inversor de tensão com seu controle, a malha de captura de fase e, por meio de um indutor de acoplamento, a conexão de todo este sistema à rede elétrica. Para a modelagem e simulações do sistema solar fotovoltaico foi utilizado o Alternative Transients Program - ATP. Inicialmente são apresentados resultados de simulação de partes constituintes do arranjo fotovoltaico e somente ao final, é realizado um estudo de caso com o sistema completo desenvolvido neste trabalho. / Mestre em Ciências
89

Desempenho de sistemas de condicionamento de ar com utilização de energia solar em edifícios de escritórios. / Performance of solar air conditioning systems in office buildings.

Paulo José Schiavon Ara 14 December 2010 (has links)
A preocupação energética tem impulsionado a humanidade a buscar alternativas sustentáveis de energia. Neste contexto, os edifícios de escritórios têm um papel importante, em especial, devido ao elevado consumo de energia dos sistemas de condicionamento de ar. Para esses sistemas, a possibilidade de utilização de energia solar é uma alternativa tecnicamente possível e interessante de ser considerada, principalmente porque, quando a carga térmica do edifício é mais elevada, a radiação solar também é mais elevada. Dentre os sistemas de condicionamento de ar solar, o sistema térmico - que associa coletores solares térmicos com chiller de absorção - é o mais disseminado, na atualidade. Entretanto, dependendo do caso, outras tecnologias podem ser vantajosas. Uma opção, por exemplo, no caso de edifícios de escritórios, é o sistema elétrico - que associa painéis fotovoltaicos ao chiller convencional de compressão de vapor. Neste trabalho, para um edifício de escritórios de 20 pavimentos e 1000 m2 por pavimento, na cidade de São Paulo, no Brasil, duas alternativas de ar condicionado solar tiveram seus desempenhos energéticos analisados: o sistema térmico - com coletores solares térmicos somente na cobertura e o sistema elétrico - com painéis FV somente nas superfícies opacas das fachadas. Para isso, com o software EnergyPlus do Departamento de Energia dos Estados Unidos obteve-se as carga térmica atuantes no edifício e com a aplicação do método de cálculo de consumo de energia dos sistemas de ar condicionado solar, proposto pelo Projeto SOLAIR da União Européia, adaptado para a realidade da pesquisa, obteve-se o desempenho energético dos sistemas. Os resultados mostraram que, para o edifício de 20 pavimentos, o sistema elétrico tem o melhor desempenho energético, economizando 28% e 71% da energia elétrica que consumiria um sistema de ar condicionado convencional, em um dia de verão e de inverno, respectivamente. O sistema térmico, ao contrário, apresentou um desempenho energético ruim para o edifício estudado, consumindo, por exemplo, em um dia de verão, cerca de 4 vezes mais energia elétrica do que um sistema de ar condicionado convencional. Constatouse que isso ocorreu, pois a área coletora limitada à cobertura foi insuficiente para atender a demanda do chiller de absorção, que passou a operar com frações solares baixas, da ordem de 50% e 20%, de pico, no dia de inverno e de verão, respectivamente. Assim, constatou-se que para que o sistema térmico apresente um desempenho energético satisfatório é preciso que o edifício não seja tão alto. De fato, os resultados mostraram que somente se o edifício tivesse no máximo 2 pavimentos, o sistema térmico teria um desempenho energético melhor do que um sistema convencional. No caso de ser aplicado ao edifício térreo de 1000m2 de área, por exemplo, esse sistema economizaria aproximadamente 65% da energia elétrica do sistema convencional. Por fim, constatou-se também que o desempenho energético do sistema térmico seria elevado com a otimização da área e da tecnologia de coletores solares, com o aprimoramento do sistema de aquecimento auxiliar e com a redução da carga térmica do edifício por meio de técnicas passivas de climatização. / Energy concern has driven human kind to seek sustainable energy alternatives. In this context, office buildings have an important role, especially due to the high energy consumption of air conditioning systems. For these systems, the possibility of using solar energy is technically feasible and interesting to be considered, mainly because generally when the building thermal load is higher, the solar radiation is also higher. Among solar airconditioning systems, the thermal system - which combines solar collectors with absorption chiller - is the most widespread, nowadays. However, depending on the case, other technologies may take advantage. One option, for example, in the case of office buildings, is the electrical system - which combines photovoltaic panels with conventional vapor compression chiller. In this work, an office building of 20 floors with 1,000 m2 floor area, in Sao Paulo, Brazil, two technologies of solar air conditioning had their performance analyzed: the thermal system - presenting solar thermal collectors only on the roof and the electrical system with PV panels only on the opaque surfaces of the facades. For this, the software EnergyPlus of the United States Department of Energy obtained the building thermal load and the with the solar air conditioning energy consumption calculating method proposed by SOLAIR project of the European Union and adapted to this work, energy performance of systems was obtained. The results showed that for this building, the electrical system had the best energy performance, saving 28% and 71% of electricity that would consume a conventional air conditioning system in a summer day and a winter day, respectively. The thermal system, in contrast, showed a poor energy performance, consuming, for example, on a summer day, about four times more electricity than a conventional air conditioning system. It was found that this occurred because the collectors area limited to the roof of the building was insufficient to meet the absorption chiller demand, causing low solar fractions in the operation, of around 50% and 20% peak, in a winter day and in a summer day, respectively. Thus, in order of provide a satisfactory energy performance, the thermal system requires that the building not to be so tall. In fact, the results showed that only if the building had up to two floors, the system would perform better than a conventional system. In case of be installed in a building with the ground floor only, and floor area of 1000m2, for example, this system would save about 65% of the electricity comparing to a conventional system. Finally, it was found that this energy performance would be elevated as well with the optimization of solar collectors area and technology, with auxiliary heating system improvement and with the reduction of thermal load of the building by means of passive air conditioning techniques.
90

Dimensionamento e gestão de energia solar fotovoltaica para aplicação em sistemas automatizados isolados da rede elétrica

Borges, Leandro da Motta 27 September 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-03-04T10:45:15Z No. of bitstreams: 1 leandrodamottaborges.pdf: 2242416 bytes, checksum: 10ac80b836250ec857dfe2dc8f819119 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-04-24T01:49:45Z (GMT) No. of bitstreams: 1 leandrodamottaborges.pdf: 2242416 bytes, checksum: 10ac80b836250ec857dfe2dc8f819119 (MD5) / Made available in DSpace on 2016-04-24T01:49:45Z (GMT). No. of bitstreams: 1 leandrodamottaborges.pdf: 2242416 bytes, checksum: 10ac80b836250ec857dfe2dc8f819119 (MD5) Previous issue date: 2013-09-27 / Este trabalho apresenta o estudo, dimensionamento e gestão de um sistema solar fotovoltaico isolado da rede elétrica para alimentar cargas de equipamentos de automação industrial. Um exemplo de aplicação são unidades de comando e sinalização ferroviária que, em alguns casos, são comandadas por relés e, mais atualmente, sendo substituídas por Controladores Lógico Programáveis. No sistema solar fotovoltaico isolado, o excedente de energia elétrica produzida nos painéis solares fotovoltaicos é armazenado em baterias eletroquímicas estacionárias de chumbo-ácido para posterior aproveitamento durante o período noturno e de baixa produção de eletricidade. Esse tipo de bateria apresenta efeito de memória, não pode sofrer descarga profunda ou ser submetida a tensões elevadas. Assim, este trabalho visa especificar e dimensionar um sistema solar fotovoltaico para aplicações em cargas de automação industrial isolados da rede elétrica, bem como assegurar elevada vida útil da bateria eletroquímica de chumbo-ácido sem prejudicar o rastreamento de máxima potência dos painéis solares fotovoltaicos. Para isso, uma estratégia de gestão de energia possibilita alterar o controle do conversor CC-CC que realiza a interconexão entre os painéis solares fotovoltaicos e a bateria eletroquímica. Resultados de simulação computacional apontam para o bom desempenho conceitual do sistema e seu potencial para a aplicação pretendida. / This work presents the study, design and management of a stand-alone photovoltaic system to feed industrial automation load. E examples of application are railway signaling unit controls, which in some cases are controlled by electromechanical relays and more currently being replaced by programmable logical controllers. In a stand-alone photovoltaic system, the excess of electricity produced in the photovoltaic panels is stored in lead-acid stationary electrochemical batteries for later use during the night and low electricity production periods. This kind of battery presents memory effect, cannot have deep discharge or be subjected to high voltages. Thus, this work aims to specify and size a solar photovoltaic system for applications in industrial automation loads isolated from the grid, as well as ensuring longer lifetime to electrochemical battery of lead-acid without harming the maximum power tracker of photovoltaic panels. For this, a strategy for changing power management enables the control of DC-DC converter that performs the interconnection of photovoltaic panels and electrochemical battery. Results of computer simulation indicate the good conceptual performance of the system and its potential for the intended application.

Page generated in 0.0901 seconds