• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • Tagged with
  • 16
  • 16
  • 16
  • 14
  • 13
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Baropodometria dinâmica de atletas remadores, com sinais e sintomas de disfunção temporomandibular, pré e pós tratamento, com placa oclusal estabilizadora e exercício terapêutico de movimento mandibular: estudo piloto / Dynamic baropodometry in rowing athletes refering signs and symptoms of temporomandibular joint dysfunction before and after using an occlusal splint associated to therapeutic mandibular exercise: pilot study

Abe, Eduardo Yujiro 02 May 2016 (has links)
A desordem temporomadibular em atletas da modalidade do remo é uma temática ainda pouco abordada na literatura, muito embora se tenha conhecimento que a biomecânica do gesto esportivo possa provocar dores lombares, fratura de costela devido ao estresse, além de dores cervicais provenientes do desprendimento de força, para atingir grande velocidade e manutendo o equilíbrio por um longo tempo. O presente estudo tem como objetivo analisar, por meio da baropodometria dinâmica, a ação da placa oclusal estabilizadora associada ao exercício terapêutico de movimento mandibular em atletas remadores diagnosticados como portadores de desordem temporomandibular (DTM). Estudos prévios demonstram que um dispositivo intraoclusal (placa oclusal estabilizadora) tem ação significante sobre o sistema de manutenção do equilíbrio corporal na postura estática. Trinta indivíduos remadores apresentaram-se como voluntários com queixa de dor, sendo 10 deles (40% homens e 60% mulheres), com idade entre 24 e 35 anos foram diagnosticados com DTM por meio do preenchimento do questionário RDC/TMD e de exame clínico. O presente estudo piloto foi caracterizado por ser um ensaio clínico, randomizado, controlado, prospectivo e de intervenção. Imediatamente após aplicação do questionário e do exame clínico, todos os indivíduos realizaram testes de baropodometria estática e dinâmica. Após esta etapa, realizou-se a randomização dos grupos por meio de software online gratuito (www.random.org) que determinou os integrantes do grupo controle, denomindado de Grupo Exercício (GE) e grupo teste denominado de Grupo Placa (GP). Ambos os grupos receberam orientação para a realização do exercício terapeutico de movimento mandibular. Definidos os integrantes do GP, foram realizados agendamento para a realização da etapa de confecção da placa oclusal. Os grupos foram monitorados por 12 semanas e após este período foram reavaliados segundo os mesmos parâmetros da etapa inicial. A análise estatísitca foi realizada utilizando o modelo ANOVA (normalidade e homoscedasticiodade),teste T-Student e teste não paramétrico de Wilcoxon. Os resultados apresentaram significância estatística na redução da dor e aumento da amplitude articular da articulação temporomandibular (ATM) no GP (p<0,05). Não foi observada significância estatísitica na análise da pressão plantar dinâmica, justificado pelo fato da insuficiência do número de invidíduos da amostra. Concluiu-se que o uso da placa oclusal foi eficaz no tratamento da DTM pela redução do quadro doloroso, entretanto, uma amostragem maior se faz necessária pra a verificação da integração entre sistema estomatognático e postural na dinâmica da marcha. / Temporomadibular joint disorder (TMJD) in rower athletes has still few studies over this theme, where the biomechanics of athletic gesture points can produce low back pain, rib stress fractures and cervical pain as resulting from power requirement to obtain high speed and body balance for repeatedly long period exercises. The aim of this study was to analyze through dynamic plantar pressure the effects of occlusal splint and therapeutic exercise of mandibular movement in rowers diagnosed as suffering from TMJD. Previous studies have shown that the occlusal splint has significant action to keep the system of body balance in standing position. 30 rower athletes came as volunteers with pain symptoms, and 10 individuals, 40% men ande 60% women, aged between 24 and 35 years, were diagnosed with TMJD through completion of the RDC/TMD questionnaire and clinical examination. The research was performed by a randomized controlled prospective clinical study besides intervention. Immediately after the questionnaire application and clinical examination, all individuals performed tests of static and dynamic baropodometry. After this procedure, the groups were randomized by using a free online software (www.random.org) which determined the members of control group, named Exercise Group (EG) and test group called Oclusal Splint Group (OSG). Both groups received guidance for performing only therapeutic exercise of mandibular movement. The OSG were scheduled for the completion of preparation stage for occlusal splint. All groups were monitored for 12 weeks and after this period were evaluated according to the same parameters of the initial step. Statistic analysis was performed by using ANOVA model (normal and homoscedasticity), t-Student test and Wilcoxon nonparametric test. The results showed statistical significance to pain relief and increase of amplitude range of jaw joint in OSG (p < 0.05). No statistical significance was observed in the analysis of dynamic plantar pressure, justified by insufficient statistic population. In conclusion the use of occlusal splint was effective in the treatment of TMJD to pain relief, however, a larger sampling is necessary to verify the integration among stomatognatic system, posture and and gait dynamics analyzes.
12

Estudo do efeito da vibração no tratamento da disfunção temporomandibular através de um protótipo de placa vibratória oclusal / Study of the effectiveness of vibratory plate in the treatment of dysfunction temporomandibular

Luca, Carlos Eduardo Pitta de 13 December 2010 (has links)
Este estudo teve como objetivo estudar uma placa oclusalcom estimulação vibratória (POV) de base, para o tratamento da dor crônica miofascial. Foram selecionados 18 pacientes com mialgia crônica facial, de acordo com os Critérios para Diagnóstico em Pesquisa RDC . Os pacientes tinham entre 18 e 65 anos de idade, pertenciam ao sexo feminino e haviam usado placa estebilizadora acrílica por mais de 6 meses, e permaneciam com dor muscular. Foram excluídos pacientes com Disfunção Temporomandibular, que haviam feito uso de analgésicos ou de moduladores de sono, e pacientes desdentados parciais ou totais. A variável analisada foi a dor reportada pelos pacientes, usando a Escala Visual Analógica (EVA) de 100mm, medindo-se antes da instalação da POV, e um mes após o seu uso. Das 18 POV instaladas, 10 apresentaram falhas no mecanismo vibratório. As médias da EVA para os 8 pacientes que utilizaram a POV durante 1 mês foram de 56,62±22.82mm na aferição inicial e média de EVA final de 24,75±20,52mm, com p=0,011. Dos 8 pacientes apenas 4 concordaram com o uso da placa oclusal inativa (POI) por 30 dias, separadas por um período de wash-out de pelo menos 8 meses. Os níveis de dor da escala VAS foram a única variável analisada, e foram registrados antes e após o uso das placas. Foram utilizadas os testes t-teste pareado e ANOVA para medidas repetidas, para se obter os resultados estatísticos. No início do estudo, os níveis médios da VAS de dor antes de se utilizar a placa vibratória de maneira ativa e inativa foram 54,5±19,8 milímetros, e 44,0±13,6 milímetros, respectivamente. A comparação entre esses valores de referência não apresentaram diferença estatística (p> 0,05, teste t pareado). A variação média nos níveis de dor (VAS póspré) ao usar o mesmo tipo de placa, de maneira ativa e inativa foi de -42,0±-30,3 milímetros e 29,5±21,5 milímetros, e o t-teste revelou uma diferença significativa entre os dois grupos (p = 0,07). Foi feitauma nova análise, utilizando-se as mesmas medidas, através da Análise de Variância ANOVA, onde encontrou-se diferença estatisticamente significante (f(3,9)=7.543, p=0.008) antes do uso das placas ativas e das inativas. Entretanto, após o uso da correção com o teste de Bonferroni, foram encontrados resultados condizentes com aqueles obtidos na análise feita pelo programa do teste t. (p>0.05). Pode-se concluir que do uso da vibração como mecanismo de controle da DTM foi eficaz, mas a POV falhou na maioria dos casos devido a problemas mecânicos. / This study aimed to study an occlusal splint with vibratory stimulation (VibsS) as standard, for the treatment of chronic myofascial pain. Were selected 18 patients with chronic facial myalgia, according to the Research Diagnostic Criteria for Temporomandibular Disorders, RDC-TMD.The patients were between 18 and 65years old, female, using stabilization splints for more than six months, and that remained with muscle pain. Were excluded patients with Temporomandibular Disorders, which had made use of analgesics or sleeps modulators and those who were partially or totally edentulous. The analyzed variable was pain reported by patients using visual analog scale (VAS) of 100mm, measuring before the installation of VibsS, and one month after its use. Were installed 18 VibsS; 10 failures in the vibrating mechanism.The mean VAS for the 8 patients who used the VibsS for 1 month were 56.62 ± 22.82mm to measure initial and final mean VAS of 24.75 ± 20.52 mm, p = 0.011. From these 8 patients, only four agreed to the use of an occlusal splints inactive for 30 days, separated by a wash-out period of at least 8 months. The levels of pain-VAS score was the only variable analyzed, and were recorded before and after use of the splints. Were used paired t-tests and ANOVA for repeated measures to obtain the statistics. At baseline, mean levels of VAS pain before using the vibrating splint active and inactive were 54.5±19.8 mm, and 44.0±13.6 mm, respectively. The comparison of these reference values showed no statistical difference (p> 0.05, paired t-test). The average change in pain levels (VAS post-pre) when using the same type of analysis, with active and inactive splints was -42.0±- 30.3 and 29.5 mm±21.5 mm, and the t-test showed a significant difference between the two groups (p = 0.07). After that, was made, a new analysis, using the same measures through the analysis of variance ANOVA, where were found a statistically significant difference (f (3,9) = 7543, p = 0.008) before the use of active boards and inactive. However, after using the correction with the Bonferroni test, we found results consistent with those obtained in the analysis performed by the test program t. (p>0.05). Conclusion: This study showed that is an effective use of vibration as a control mechanism of TMD, but this VibsS failed in most cases due to mechanical problems.
13

Estudo do efeito da vibração no tratamento da disfunção temporomandibular através de um protótipo de placa vibratória oclusal / Study of the effectiveness of vibratory plate in the treatment of dysfunction temporomandibular

Carlos Eduardo Pitta de Luca 13 December 2010 (has links)
Este estudo teve como objetivo estudar uma placa oclusalcom estimulação vibratória (POV) de base, para o tratamento da dor crônica miofascial. Foram selecionados 18 pacientes com mialgia crônica facial, de acordo com os Critérios para Diagnóstico em Pesquisa RDC . Os pacientes tinham entre 18 e 65 anos de idade, pertenciam ao sexo feminino e haviam usado placa estebilizadora acrílica por mais de 6 meses, e permaneciam com dor muscular. Foram excluídos pacientes com Disfunção Temporomandibular, que haviam feito uso de analgésicos ou de moduladores de sono, e pacientes desdentados parciais ou totais. A variável analisada foi a dor reportada pelos pacientes, usando a Escala Visual Analógica (EVA) de 100mm, medindo-se antes da instalação da POV, e um mes após o seu uso. Das 18 POV instaladas, 10 apresentaram falhas no mecanismo vibratório. As médias da EVA para os 8 pacientes que utilizaram a POV durante 1 mês foram de 56,62±22.82mm na aferição inicial e média de EVA final de 24,75±20,52mm, com p=0,011. Dos 8 pacientes apenas 4 concordaram com o uso da placa oclusal inativa (POI) por 30 dias, separadas por um período de wash-out de pelo menos 8 meses. Os níveis de dor da escala VAS foram a única variável analisada, e foram registrados antes e após o uso das placas. Foram utilizadas os testes t-teste pareado e ANOVA para medidas repetidas, para se obter os resultados estatísticos. No início do estudo, os níveis médios da VAS de dor antes de se utilizar a placa vibratória de maneira ativa e inativa foram 54,5±19,8 milímetros, e 44,0±13,6 milímetros, respectivamente. A comparação entre esses valores de referência não apresentaram diferença estatística (p> 0,05, teste t pareado). A variação média nos níveis de dor (VAS póspré) ao usar o mesmo tipo de placa, de maneira ativa e inativa foi de -42,0±-30,3 milímetros e 29,5±21,5 milímetros, e o t-teste revelou uma diferença significativa entre os dois grupos (p = 0,07). Foi feitauma nova análise, utilizando-se as mesmas medidas, através da Análise de Variância ANOVA, onde encontrou-se diferença estatisticamente significante (f(3,9)=7.543, p=0.008) antes do uso das placas ativas e das inativas. Entretanto, após o uso da correção com o teste de Bonferroni, foram encontrados resultados condizentes com aqueles obtidos na análise feita pelo programa do teste t. (p>0.05). Pode-se concluir que do uso da vibração como mecanismo de controle da DTM foi eficaz, mas a POV falhou na maioria dos casos devido a problemas mecânicos. / This study aimed to study an occlusal splint with vibratory stimulation (VibsS) as standard, for the treatment of chronic myofascial pain. Were selected 18 patients with chronic facial myalgia, according to the Research Diagnostic Criteria for Temporomandibular Disorders, RDC-TMD.The patients were between 18 and 65years old, female, using stabilization splints for more than six months, and that remained with muscle pain. Were excluded patients with Temporomandibular Disorders, which had made use of analgesics or sleeps modulators and those who were partially or totally edentulous. The analyzed variable was pain reported by patients using visual analog scale (VAS) of 100mm, measuring before the installation of VibsS, and one month after its use. Were installed 18 VibsS; 10 failures in the vibrating mechanism.The mean VAS for the 8 patients who used the VibsS for 1 month were 56.62 ± 22.82mm to measure initial and final mean VAS of 24.75 ± 20.52 mm, p = 0.011. From these 8 patients, only four agreed to the use of an occlusal splints inactive for 30 days, separated by a wash-out period of at least 8 months. The levels of pain-VAS score was the only variable analyzed, and were recorded before and after use of the splints. Were used paired t-tests and ANOVA for repeated measures to obtain the statistics. At baseline, mean levels of VAS pain before using the vibrating splint active and inactive were 54.5±19.8 mm, and 44.0±13.6 mm, respectively. The comparison of these reference values showed no statistical difference (p> 0.05, paired t-test). The average change in pain levels (VAS post-pre) when using the same type of analysis, with active and inactive splints was -42.0±- 30.3 and 29.5 mm±21.5 mm, and the t-test showed a significant difference between the two groups (p = 0.07). After that, was made, a new analysis, using the same measures through the analysis of variance ANOVA, where were found a statistically significant difference (f (3,9) = 7543, p = 0.008) before the use of active boards and inactive. However, after using the correction with the Bonferroni test, we found results consistent with those obtained in the analysis performed by the test program t. (p>0.05). Conclusion: This study showed that is an effective use of vibration as a control mechanism of TMD, but this VibsS failed in most cases due to mechanical problems.
14

Baropodometria dinâmica de atletas remadores, com sinais e sintomas de disfunção temporomandibular, pré e pós tratamento, com placa oclusal estabilizadora e exercício terapêutico de movimento mandibular: estudo piloto / Dynamic baropodometry in rowing athletes refering signs and symptoms of temporomandibular joint dysfunction before and after using an occlusal splint associated to therapeutic mandibular exercise: pilot study

Eduardo Yujiro Abe 02 May 2016 (has links)
A desordem temporomadibular em atletas da modalidade do remo é uma temática ainda pouco abordada na literatura, muito embora se tenha conhecimento que a biomecânica do gesto esportivo possa provocar dores lombares, fratura de costela devido ao estresse, além de dores cervicais provenientes do desprendimento de força, para atingir grande velocidade e manutendo o equilíbrio por um longo tempo. O presente estudo tem como objetivo analisar, por meio da baropodometria dinâmica, a ação da placa oclusal estabilizadora associada ao exercício terapêutico de movimento mandibular em atletas remadores diagnosticados como portadores de desordem temporomandibular (DTM). Estudos prévios demonstram que um dispositivo intraoclusal (placa oclusal estabilizadora) tem ação significante sobre o sistema de manutenção do equilíbrio corporal na postura estática. Trinta indivíduos remadores apresentaram-se como voluntários com queixa de dor, sendo 10 deles (40% homens e 60% mulheres), com idade entre 24 e 35 anos foram diagnosticados com DTM por meio do preenchimento do questionário RDC/TMD e de exame clínico. O presente estudo piloto foi caracterizado por ser um ensaio clínico, randomizado, controlado, prospectivo e de intervenção. Imediatamente após aplicação do questionário e do exame clínico, todos os indivíduos realizaram testes de baropodometria estática e dinâmica. Após esta etapa, realizou-se a randomização dos grupos por meio de software online gratuito (www.random.org) que determinou os integrantes do grupo controle, denomindado de Grupo Exercício (GE) e grupo teste denominado de Grupo Placa (GP). Ambos os grupos receberam orientação para a realização do exercício terapeutico de movimento mandibular. Definidos os integrantes do GP, foram realizados agendamento para a realização da etapa de confecção da placa oclusal. Os grupos foram monitorados por 12 semanas e após este período foram reavaliados segundo os mesmos parâmetros da etapa inicial. A análise estatísitca foi realizada utilizando o modelo ANOVA (normalidade e homoscedasticiodade),teste T-Student e teste não paramétrico de Wilcoxon. Os resultados apresentaram significância estatística na redução da dor e aumento da amplitude articular da articulação temporomandibular (ATM) no GP (p<0,05). Não foi observada significância estatísitica na análise da pressão plantar dinâmica, justificado pelo fato da insuficiência do número de invidíduos da amostra. Concluiu-se que o uso da placa oclusal foi eficaz no tratamento da DTM pela redução do quadro doloroso, entretanto, uma amostragem maior se faz necessária pra a verificação da integração entre sistema estomatognático e postural na dinâmica da marcha. / Temporomadibular joint disorder (TMJD) in rower athletes has still few studies over this theme, where the biomechanics of athletic gesture points can produce low back pain, rib stress fractures and cervical pain as resulting from power requirement to obtain high speed and body balance for repeatedly long period exercises. The aim of this study was to analyze through dynamic plantar pressure the effects of occlusal splint and therapeutic exercise of mandibular movement in rowers diagnosed as suffering from TMJD. Previous studies have shown that the occlusal splint has significant action to keep the system of body balance in standing position. 30 rower athletes came as volunteers with pain symptoms, and 10 individuals, 40% men ande 60% women, aged between 24 and 35 years, were diagnosed with TMJD through completion of the RDC/TMD questionnaire and clinical examination. The research was performed by a randomized controlled prospective clinical study besides intervention. Immediately after the questionnaire application and clinical examination, all individuals performed tests of static and dynamic baropodometry. After this procedure, the groups were randomized by using a free online software (www.random.org) which determined the members of control group, named Exercise Group (EG) and test group called Oclusal Splint Group (OSG). Both groups received guidance for performing only therapeutic exercise of mandibular movement. The OSG were scheduled for the completion of preparation stage for occlusal splint. All groups were monitored for 12 weeks and after this period were evaluated according to the same parameters of the initial step. Statistic analysis was performed by using ANOVA model (normal and homoscedasticity), t-Student test and Wilcoxon nonparametric test. The results showed statistical significance to pain relief and increase of amplitude range of jaw joint in OSG (p < 0.05). No statistical significance was observed in the analysis of dynamic plantar pressure, justified by insufficient statistic population. In conclusion the use of occlusal splint was effective in the treatment of TMJD to pain relief, however, a larger sampling is necessary to verify the integration among stomatognatic system, posture and and gait dynamics analyzes.
15

Efeitos do uso da placa oclusal sobre o equilíbrio postural em indivíduos dentados, não reprogramados, com sinais e sintomas de desordem temporomandibular diagnosticados pelo RDC/TMD e ressonância magnética / Effects of using occlusal splint on postural equilibrium in dentate, non-reprogrammed, individual with signs and symptoms of temporomandibular disorder diagnosed via RDC/TMD and magnetic-resonance imaging

Simone Saldanha Ignacio de Oliveira 08 May 2013 (has links)
A desordem temporomandibular (DTM) de origem multifatorial pode estar associada a fatores oclusais e também a alterações posturais. O objetivo desse estudo foi investigar os efeitos do uso da placa sobre o equilíbrio postural em indivíduos dentados, não reprogramados, com sinais e sintomas de desordem temporomandibular (DTM). Colaboraram com a pesquisa 70 pacientes (59 placa e 21 controle), entre 18e 84 anos, de ambos os gêneros, diagnosticados com DTM por meio do questionário do RDC/TMD além de ressonância magnética da articulação temporomandibular. O estudo foi de ensaio clínico, randomizado, controlado, prospectivo e de intervenção. Foram respondidos os questionários de risco de quedas - FES-I e de qualidade de vida - SF-36 antes que fosse realizada a avaliação do equilíbrio postural por meio da plataforma de força. Cumprida estas etapas eram feita a randomização: o grupo da amostra recebia placa oclusal com critérios de estabilidade oclusal além de orientação para que fizesse exercícios terapêuticos, enquanto o grupo controle era orientado para fazer apenas exercícios terapêuticos. Após 12 semanas, os dois grupos eram reavaliados. A análise estatística foi feita por frequências, avaliação da associação entre grupos por teste de Fisher; medidas quantitativas considerando por média, mediana, desvio padrão, percentis 25 e 75 além de valores máximo e mínimo; as comparações entre os tempos fez uso de teste não paramétrico de Wilcoxon enquanto a entre grupos usou o teste de Mann-Whitney, com nível de significância de 5%. O total de pacientes, que completou o estudo de risco de queda e qualidade de vida, era composto por 77% de mulheres, com média de idade de 42,5 anos. Os itens significantes do risco de queda contribuíram para reduzir a preocupação em cair da mesma forma que os de qualidade de vida auxiliaram o aumento dos domínios saúde mental, dor e vitalidade. Dos setenta pacientes, 64 completaram o RDC/TMD (47 placa e 17 controle), com diferenças significativas no que diz respeito ao diagnóstico de dor miofascial, deslocamento do disco, artralgia direita e esquerda, grau de dor crônica, depressão esomatização relacionada a placa. Dentre os mesmos 70 pacientes, 49 completaram o estudo sobre o equilíbrio postural (36 placa e 13 controle), que apresentou aumento significante na velocidade anteroposterior do CP nas condições olhos abertos e fechados (VAPoa e VAPof), durante a postura em pé no grupo placa. Concluiu-seque o uso da placa foi eficaz no tratamento da DTM sendo que seu efeito pode ser observado no equilíbrio postural a ponto de diminuir a preocupação em cair além de melhorar os domínios de saúde mental e dor, com consequente repercussão sobre a qualidade de vida. / Temporomandibular disorder (TMD) of multifactorial origin may be associated with occlusal factors but also with changes in posture. The objective of this study was to investigate the effects of the use of the occlusal splint on the postural equilibrium of non-reprogrammed, dentate individual with signs and symptoms of temporomandibular disorder. The research group consisted of 70 patients (59 with occlusal splints, 21 in the control group) between 18 and 84 years of age, of both genders, diagnosed with TMD by way of the RDC/TMD questionnaire and magnetic-resonance imaging of the temporomandibular joint. The research was performed via a randomized, controlled, prospective clinical study and intervention. The questionnaires regarding risk of falls - FES-I and quality of life - SF-36 were filled out before evaluating postural equilibrium by way of a force platform. In the randomization, the sample group received occlusal splint, occlusal-stability criteria, and advice about therapeutic exercises; the control group only received advice about therapeutic exercises. After 12 weeks, the groups were re-evaluated qualitatively by frequency, evaluation of the association between the group via Fisher testing; quantitatively via average, median, standard deviation, 25 and 75 percentiles, and minimum and maximum values; comparison between the times via non-parametric Wilcoxon testing and between the groups via Mann-Whitney testing with a threshold of significance of 5 %. Of the universe of the patients who completed the risk-of-fall and quality-of-life study, 77 % were women with an average of of 42.2 years. The items that were significant to the risk of falling contributed to reducing fear of falling, and those significant to quality of life to increasing the domains of mental health, pain, and vitality. Out of the 70 participants, 64 completed the RDC/TMD (47 occlusal splint and 17 controls) with differences that were significant to the diagnosis of miofascial pain, slipped disc, left and right arthralgia, degree of chronic pain, depression, and somatization related to the oclusal splint. Of the 70, 49 completed the postural-equilibrium study (36 occlusal splint and 13 controls), a significant increase in anteroposterior speed of the COP with eyes open and eyes closed (AVPeo and AVPec) occurring in the oclusal splint group while standing. It is therefore concluded that use of the oclusal splint was efficacious in the treatment of TJM and that there was an effect on the postural equilibrium, with improvement occurring in regards to fear of falls and in the domains of mental health, pain, and the quality of life.
16

Influência da intensidade de carregamento e utilização de placa oclusal plana em supraestruturas metálicas parafusadas sobre implantes: estudo fotoelástico / Influence of the intensity of loading and use of an occlusal splint flat screw-retained metal superstructures on implants: photoelastic study

Fabíola Marchezini Teixeira 30 August 2010 (has links)
Objetivo: Avaliar por meio do estudo fotoelástico qualitativo as tensões geradas no longo eixo dos implantes e interimplantes nas regiões cervical, média e apical quando submetidos a diferentes carregamentos com ou sem interposição de placa oclusal plana. Método: Foram confeccionados quatro modelos fotoelásticos, com dois implantes hexágono externo (Neodent) localizados no espaço correspondente ao segundo pré-molar e segundo molar inferiores. Em cada modelo, foram instaladas supraestruturas metálicas parafusadas sobre os implantes. Os modelos fotoelásticos foram posicionados no polariscópio circular para distribuição das franjas isocromáticas em torno dos implantes e áreas interimplantes. Registros fotográficos foram obtidos antes e após a aplicação dos diferentes tipos de carregamento: 1- 30kg sem placa; 2- 30kg com placa; 3- 60kg sem placa; 4- 60kg com placa; 5- 90kg sem placa; 6- 90kg com placa. Resultados: Após as análises, observou-se a presença de tensão nos modelos sem a aplicação de carga oclusal após a aplicação do torque (20Ncm). A diminuição na magnitude de tensão com a aplicação da placa oclusal plana se tornou mais evidente após a aplicação de carga de 60kg. De modo geral, a maior magnitude de tensão se deu na região cervical para as áreas interimplantares e na região apical ao redor dos implantes, havendo uma diminuição de 57,77% entre as três magnitudes de cargas aplicadas após utilização da placa. Conclusões: Assim, os dados obtidos deste estudo demonstraram que a melhor distribuição de tensões nos implantes foi obtida com a interposição da placa oclusal plana, a partir da aplicação de carga de 60kg, com diminuição de 66,66%. / Aim: To assess using qualitative photoelastic studies the tensions generated in the long axis of the implants and interimplants in the cervical, middle and apical regions when subjected to different loads with or without interposition of occlusal splint flat. Methods: Four photoelastic models were fabricated with two external hexagon implants (Neodent) located in the space corresponding to the second premolar and molar inferiors. In each model, screw-retained metal superstructures were installed on the implants. Photoelastic models were positioned in the circular polariscope for distribution of isochromatic fringes around the implants. Photographic records were obtained before and after application of different types of loading: 1- 30kg without plate; 2- 30kg with plate; 3- 60kg without plate; 4- 60kg with plate; 5- 90kg without plate; 6- 90kg with plate. Results: After the analysis, the presence of tension in the models without the application of occlusal load after torque application (20Ncm) was observed. The decrease in stress with the application of the occlusal splint flat became more evident after the application of 60kg load. Generally, the major stress magnitude occurred in the cervical region for interimplant areas and in the apical region around implants, with a decrease of 57,77%, between the three magnitudes of loads applied after use of plate. Conclusions: The data obtained in this studies demonstrate that the best stress distribution in the implants is obtained by interposing occlusal splint flat, with the application of a 60kg load, and a decrease of 66,66%.

Page generated in 0.0665 seconds