• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 115
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 122
  • 118
  • 64
  • 33
  • 22
  • 19
  • 18
  • 16
  • 14
  • 13
  • 12
  • 12
  • 11
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Urbe água vida: ética da proteção aplicada ao estudo de implicações morais no acesso desigual à água potável / Urbe water life: ethics of the protection applied to the study of moral implications in the different access to pole water

Pontes, Carlos Antonio Alves January 2003 (has links)
Made available in DSpace on 2012-09-05T18:23:38Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 220.pdf: 864830 bytes, checksum: f67233b796d256b6338299961e98be01 (MD5) Previous issue date: 2003 / Este trabalho tem por objetivo examinar o acesso desigual à água potável, como problemática de saúde pública, identificando e analisando as implicações morais do atendimento desigual de necessidades primárias, as situações de fragilidade e ameaça de grupos populacionais e as responsabilidades públicas para com o abastecimento de água; e propondo soluções, em bases racionais, para a construção de uma sociedade justa e equânime, comprometida com a proteção da saúde de seus membros, bem como com a promoção de seus legítimos projetos de desenvolvimento pessoal. Para tanto, é utilizada a Ética da Proteção, como uma teoria moral apropriada para a abordagem desses problemas, pertinentes ao campo da bioética social. A aplicação da Ética da Proteção nos permitiu reafirmar o papel do Estado, como responsável pela prestação dos serviços de saneamento, e em particular de abastecimento de água; e pela vigilância e controle da qualidade da água para consumo humano, ao mesmo tempo em que desaconselha as políticas de privatização em favor de políticas públicas, que visem à correção de situações de injustiça social, protejam a saúde das populações e em especial dos grupos populacionais constantemente ameaçados, e promovam condições para uma melhor qualidade de vida. A Ética da Proteção, aplicada ao estudo de uma situação real de grupos populacionais na cidade do Recife, com dados coletados mediante o uso da técnica de grupos focais e aplicação de questionário, revelou-nos as deficiências da prestação dos serviços públicos de água, que devem ser superadas com mudanças nas relações entre os agentes públicos e a população. Para uma compreensão abrangente do problema do acesso desigual à água potável é feita uma contextualização dos múltiplos usos da água no mundo, enfocando a disponibilidade hídrica, a distribuição regional dos usos, e as propostas para o enfrentamento do problema de escassez de água doce; e traçado um breve histórico da formação dos ambientes urbanos e do desenvolvimento das técnicas de obtenção e tratamento de água. Procura-se, ainda, caracterizar o atendimento por abastecimento de água, em escala mundial, e a prestação desse serviço no Brasil, destacando a natureza e as responsabilidades dos agentes públicos prestadores de serviços e autoridades sanitárias. Também é feita uma caracterização do abastecimento de água da cidade de Recife.
22

Vigilância da qualidade da água para consumo humano: estudo de clorofenóis / Quality surveilleance of water for human consumption: study of chlorphenols

Sartori, André Victor January 2007 (has links)
Made available in DSpace on 2014-07-28T18:09:57Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 114.pdf: 598002 bytes, checksum: 3c505a008627bfa98ab5aadf9fc1f388 (MD5) Previous issue date: 2007 / Made available in DSpace on 2014-12-22T16:56:34Z (GMT). No. of bitstreams: 2 114.pdf: 598002 bytes, checksum: 3c505a008627bfa98ab5aadf9fc1f388 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2007 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde / Clorofenóis consistem de um grupo de 19 isômeros incluindo mono-, di-, tri- e tretraclorofenóis, e o pentaclorofenol (PCF). São substâncias orgânicas sintéticas obtidas em larga escala industrial e comercial. Muitos são utilizados como agrotóxicos, principalmente como fungicidas para preservação de madeira. A presença de clorofenóis em sistemas hídricos é de grande interesse, devido à variedade de fontes contaminantes e propriedades físico-químicas dessas substâncias. O processo de desinfecção da água para consumo humano por cloração em presença de substâncias fenólicas pode resultar na formação de clorofenóis. O 2,4,6- Triclorofenol (2,4,6-TCF) é o principal isômero formado através desse processo. Clorofenóis são especialmente tóxicos e potencialmente carcinogênicos. Muitos são considerados poluentes prioritários para serem monitorados em água pela União Européia e pela agência de proteção ambiental dos Estados Unidos. A Portaria n. 518/2004, norma de potabilidade vigente no Brasil, inclue dois clorofenóis: 2,4,6-TCF e PCF, e estabelece o valor máximo permitido de 200 ng/mL e 9 ng/mL, respectivamente. Este estudo teve por objetivo implementar e validar metodologias analíticas para determinação de clorofenóis em água para consumo humano, em níveis de concentração exigidos, utilizando técnica de Cromatografia à Gás acoplada ao Detector Seletivo de Massas (CG-DSM). Incluem-se outros congêneres, além dos contemplados na referida portaria, sabendo-se do potencial de contaminação e da toxicidade dos mesmos. Foi avaliada a qualidade da água de sistemas e soluções alternativas de abastecimento do Município do Rio de Janeiro. Dois métodos analíticos foram validados, os quais demonstraram serem adequados aos objetivos do estudo. Podem ser utilizados em rotinas de controle e ações de vigilância da qualidade da água para consumo humano. As substâncias investigadas incluem todos os isômeros tri- e tetraclorofenóis, e o pentaclorofenol. / Chlorophenols consist of a group of 19 different isomers which include mono-, di-, tri- and tetrachlorophenols, and pentachlorophenol (PCF). They are synthetic organic compounds, obtained on large industrial and commercial scales. Many of them are widely used as pesticides, mainly as fungicides for wood protection. The presence of chlorophenols in the aquatic environment is of great concern, due to their physical and chemical proprieties and the variety of contamination sources. Drinking water disinfection by chlorination treatments may form chlorophenols when phenolic compounds are already present in raw water. 2,4,6- Triclorofenol (2,4,6-TCF) is the main isomer formed through this process. According to the International Agency for Research on Cancer, Chlorophenols are classified as. possibly carcinogenic compounds (Group 2B). Therefore, most of them are considered high-priority pollutants in water by the European Union and the United States Environmental Protection Agency. Regulation Nº. 518/2004, the effective Brazilian potability norm, includes two chlorophenols: 2,4,6-TCF and PCF, and establish the maximum concentration acceptance of 200 ng/mL and 9 ng/mL, respectively. The objective of this study was to implement and validate analytical methods for the determination of chlorophenols in drinking water at levels of the concentration limits established in the potability norm. Two methods were validated for the determination of pentachlorophenol and all isomers of the tri- and tetrachlorophenols. Instrumental analysis has been done by gas chromatography and mass spectrometry. Both methods had shown to be suitable in the scope of the study, fast, easy to execute and not expensive. All studied analytes presented linear working range and correlation coefficients between 0,9988 and 0,9997. The recovery rates varied from 75 to 103%, and variation coefficients were all lower than 15%. After validation, water quality was evaluated in samples collected from common water supply systems and alternative solutions in the Municipality of Rio de Janeiro. 2,4,6-TCF residues were detected in 36% of the 28 analysed samples, varying from 0,008 to 0,238 ng/mL, and all other analytes were below quantitation limit. These results indicate that chlorophenols levels in the sampled drinking water supplies are well below the regulation limits. The validated methods had been shown to be suitable for application in quality control routines and surveillance action by public health authorities.
23

Implementação de método rápido e de baixo custo no LACEN/RJ para avaliação de organoclorados em água de soluções alternativas de abastecimento / Development of a fast and low cost method at LACEN/RJ for assessment of organochlorines in drinking water from wells

Novotny, Thiago Santana January 2009 (has links)
Made available in DSpace on 2015-02-27T17:39:02Z (GMT). No. of bitstreams: 2 76.pdf: 1337746 bytes, checksum: c97b92460d1afa99fa7e64e58c7a94a9 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde / A disponibilidade de água potável e segura é um direito e uma condição indispensável para vida, garantidos pela Constituição Federal e pelo Sistema Único de Saúde (SUS). Em sua tabela 3, a Portaria 518/2004 - MS apresenta o padrão de potabilidade para substâncias químicas que representam risco à saúde e estabelece os valores máximos permitidos (VMP) em água para consumo humano para uma série de agrotóxicos, em sua maioria substâncias organocloradas. No entanto, somente a água distribuída pela rede geral de abastecimento tem a sua qualidade avaliada através do monitoramento realizado pelas companhias distribuidoras em seus laboratórios. O monitoramento da água das soluções alternativas apresenta uma dificuldade peculiar, pois muitas vezes não há um responsável ao qual possa ser formalmente imputado o controle da qualidade da água fornecida. No sentido de atender a necessidade de monitoramento da água das soluções alternativas, o objetivo principal deste trabalho foi a validação e a implementação de um método para análise de agrotóxicos organoclorados em água potável no Laboratório Central Noel Nutels/Rio de Janeiro visando o menor custo, menor tempo de execução, e menor geração de resíduos. O método escolhido foi a microextração líquido-líquido dispersiva (MELLD), onde uma mistura de solvente de extração, mais denso e imiscível no meio aquoso, com um solvente de dispersão miscível em ambos, é rapidamente injetada na amostra aquosa por meio de uma seringa. A análise instrumental foi efetuada por cromatografia à gás com detecção por captura de elétrons. O método foi validado para 12 agrotóxicos sendo: 4,4 -DDT, 2,4 -DDT, alfa-endossulfam, beta-endossulfam, alfa-HCH, beta-HCH, gama-HCH, delta-HCH, endrin, hexaclorobenzeno, metoxicloro e trifuralina. Os parâmetros de validação verificados encontraram-se todos dentro das faixas exigidas pelas normas em vigor. / A disponibilidade de água potável e segura é um direito e uma condição indispensável para vida, garantidos pela Constituição Federal e pelo Sistema Único de Saúde (SUS). Em sua tabela 3, a Portaria 518/2004 - MS apresenta o padrão de potabilidade para substâncias químicas que representam risco à saúde e estabelece os valores máximos permitidos (VMP) em água para consumo humano para uma série de agrotóxicos, em sua maioria substâncias organocloradas. No entanto, somente a água distribuída pela rede geral de abastecimento tem a sua qualidade avaliada através do monitoramento realizado pelas companhias distribuidoras em seus laboratórios. O monitoramento da água das soluções alternativas apresenta uma dificuldade peculiar, pois muitas vezes não há um responsável ao qual possa ser formalmente imputado o controle da qualidade da água fornecida. No sentido de atender a necessidade de monitoramento da água das soluções alternativas, o objetivo principal deste trabalho foi a validação e a implementação de um método para análise de agrotóxicos organoclorados em água potável no Laboratório Central Noel Nutels/Rio de Janeiro visando o menor custo, menor tempo de execução, e menor geração de resíduos. O método escolhido foi a microextração líquido-líquido dispersiva (MELLD), onde uma mistura de solvente de extração, mais denso e imiscível no meio aquoso, com um solvente de dispersão miscível em ambos, é rapidamente injetada na amostra aquosa por meio de uma seringa. A análise instrumental foi efetuada por cromatografia à gás com detecção por captura de elétrons. O método foi validado para 12 agrotóxicos sendo: 4,4’-DDT, 2,4’-DDT, alfa-endossulfam, beta-endossulfam, alfa-HCH, beta-HCH, gama-HCH, delta-HCH, endrin, hexaclorobenzeno, metoxicloro e trifuralina. Os parâmetros de validação verificados encontraram-se todos dentro das faixas exigidas pelas normas em vigor. O teste com duas misturas de solvente de extração revelou que a mistura tetracloroetileno/acetona apresentou os melhores resultados em comparação com a de clorobenzeno/acetona. A análise de 10 amostras de água provenientes de soluções alternativas de abastecimento espalhadas pelo município de São José do Vale do Rio Preto/RJ mostrou que não há contaminação pelos agrotóxicos estudados, sendo todos os valores obtidos abaixo do limite de quantificação.
24

Implementação de método rápido e de baixo custo no LACEN/RJ para avaliação de organoclorados em água de soluções alternativas de abastecimento / Development of a fast and low cost method at LACEN/RJ for assessment of organochlorines in drinking water from wells

Novotny, Thiago Santana January 2009 (has links)
Made available in DSpace on 2012-05-07T15:02:17Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 000006.pdf: 1337746 bytes, checksum: c97b92460d1afa99fa7e64e58c7a94a9 (MD5) Previous issue date: 2009 / Made available in DSpace on 2016-07-29T14:54:55Z (GMT). No. of bitstreams: 4 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 000006.pdf: 1337746 bytes, checksum: c97b92460d1afa99fa7e64e58c7a94a9 (MD5) 000006.pdf.txt: 149863 bytes, checksum: f0ad50422f0378083c2fd5988d88b242 (MD5) 000006.pdf.jpg: 1120 bytes, checksum: 262dc8443fb7c361a07a1b5852f65188 (MD5) Previous issue date: 2009 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde / A disponibilidade de água potável e segura é um direito e uma condição indispensável para vida, garantidos pela Constituição Federal e pelo Sistema Único de Saúde (SUS). Em sua tabela 3, a Portaria 518/2004 - MS apresenta o padrão de potabilidade para substâncias químicas que representam risco à saúde e estabelece os valores máximos permitidos (VMP) em água para consumo humano para uma série de agrotóxicos, em sua maioria substâncias organocloradas. No entanto, somente a água distribuída pela rede geral de abastecimento tem a sua qualidade avaliada através do monitoramento realizado pelas companhias distribuidoras em seus laboratórios. O monitoramento da água das soluções alternativas apresenta uma dificuldade peculiar, pois muitas vezes não há um responsável ao qual possa ser formalmente imputado o controle da qualidade da água fornecida. No sentido de atender a necessidade de monitoramento da água das soluções alternativas, o objetivo principal deste trabalho foi a validação e a implementação de um método para análise de agrotóxicos organoclorados em água potável no Laboratório Central Noel Nutels/Rio de Janeiro visando o menor custo, menor tempo de execução, e menor geração de resíduos. O método escolhido foi a microextração líquido-líquido dispersiva (MELLD), onde uma mistura de solvente de extração, mais denso e imiscível no meio aquoso, com um solvente de dispersão miscível em ambos, é rapidamente injetada na amostra aquosa por meio de uma seringa. A análise instrumental foi efetuada por cromatografia à gás com detecção por captura de elétrons. O método foi validado para 12 agrotóxicos sendo: 4,4’-DDT, 2,4’-DDT, alfa-endossulfam, beta-endossulfam, alfa-HCH, beta-HCH, gama-HCH, delta-HCH, endrin, hexaclorobenzeno, metoxicloro e trifuralina. Os parâmetros de validação verificados encontraram-se todos dentro das faixas exigidas pelas normas em vigor. O teste com duas misturas de solvente de extração revelou que a mistura tetracloroetileno/acetona apresentou os melhores resultados em comparação com a de clorobenzeno/acetona. A análise de 10 amostras de água provenientes de soluções alternativas de abastecimento espalhadas pelo município de São José do Vale do Rio Preto/RJ mostrou que não há contaminação pelos agrotóxicos estudados, sendo todos os valores obtidos abaixo do limite de quantificação. / The availability of safe drinking water is a right and a prerequisite for life, guaranteed by the Constitution and the Unified Health System. In its table 3, the Ministry of Health ordinance n° 518/2004 presents the drinking water standards for chemicals that pose risk to health and sets the maximum contaminant level in water for human consumption to a number os pesticides, most of them organochlorinated substances. However, only the water distributed by the public supply network has its quality assessed by monitoring conducted in distributing companies’ laboratories. Monitoring the water from alternative sources presents a peculiar difficulty, because often there is no controller who could be formally responsible for the quality of the water being supplied. In order to meet the need for monitoring the water from alternative sources, the main objective of this study was to validate and to implement a method for analysis of organochlorine pesticides in drinking water at Noel Nutels Central Laboratory / Rio de Janeiro aiming the lower cost, lower execution time, and less waste generation. The chosen method was the dispersive liquid-liquid microextraction (DLLME), where a mixture of an extraction solvent, more dense and immiscible in water, with a dispersion solvent, miscible in both, is rapidly injected in the aqueous sample through a syringe. The instrumental analysis was performed by gas chromatography with electron-capture detection. The method was validated for 12 pesticides: 4,4’DDT, 2,4'DDT, alpha-endosulfan, beta-endosulfan, alpha-HCH, beta-HCH, gamma-HCH, delta-HCH, endrin, hexachlorobenzene, methoxychlor and trifluralin. The validation parameters were all in the range required by current protocols. The test between two mixtures of extraction solvents showed that the mixture tetrachlorethylene/acetone provided the best results in comparison with chlorobenzene/acetone. The analysis of 10 water samples from alternative supply sources throughout the municipality of São José do Vale do Rio Preto/RJ showed no contaminations by the pesticides studied, and all obtained values were below the quantification limits.
25

Tratamento de água de chuva através de filtração lenta e desinfecção UV

Bastos, Fernanda Pereira 30 July 2007 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2016-05-18T19:28:17Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Fernanda Bastos.pdf: 2383262 bytes, checksum: 97593c61028106e6c41a5fb1222c092c (MD5) / Approved for entry into archive by Patricia Barros (patricia.barros@ufes.br) on 2016-06-14T18:04:40Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Fernanda Bastos.pdf: 2383262 bytes, checksum: 97593c61028106e6c41a5fb1222c092c (MD5) / Made available in DSpace on 2016-06-14T18:04:40Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Fernanda Bastos.pdf: 2383262 bytes, checksum: 97593c61028106e6c41a5fb1222c092c (MD5) / Diante de problemas de escassez de água na atualidade, o uso de fontes alternativas de suprimento é citado como solução para a conservação de água. Dentre essas fontes destaca-se o aproveitamento de água de chuva, que se caracteriza por ser uma solução simples e barata para se preservar água potável. Dentro deste contexto, esta pesquisa promoveu uma caracterização da água da chuva, viabilizando um sistema de tratamento desta água que tenha menor demanda operacional possível e que contribua para melhorar a qualidade de vida de populações que não têm acesso à água potável, com o menor impacto possível ao meio ambiente. Este trabalho estabelece as diretrizes para a concepção e elaboração de um projeto de abastecimento de água, onde o tratamento será através de Filtros Lentos e desinfecção ultravioleta, uma vez que a cloração – método mais tradicional – demanda um custo operacional mais elevado e também é rejeitada por algumas comunidades, devido ao sabor conferido à água clorada. Para a captação da água da chuva utilizaram-se os telhados dos prédios localizados no Parque Experimental do Núcleo Água, que foram construídos com telha metálica e possuem área de projeção total de, aproximadamente, 180m². Anexo ao prédio construiu-se um sistema de armazenamento e tratamento da água da chuva, composto por dois filtros lentos verticais e lâmpadas ultravioleta. A caracterização foi realizada por meio de 12 análises físico-químicas semanais: temperatura, pH, turbidez, cor verdadeira, sólidos suspensos, dissolvidos e totais, acidez, alcalinidade, dureza, cloretos, sendo que as três primeiras eram realizadas diariamente. E por meio de análises microbiológicas, como: coliformes termotolerantes, coliformes totais e Escherichia coli. Foi analisada a água de chuva sem tratamento, após passagem pelos filtros lentos com diferentes taxas de filtração (4, 6 e 8 m3/m2.dia) e após passagem pela desinfecção UV, com intensidade média de 0,57 mW/cm2. A água de chuva analisada pode ser classificada de acordo com o CONAMA 357/05 como de classe 1 e de acordo com a NBR 12.216/92 como tipo B, sendo necessária em ambas classificações um tratamento para o consumo humano. A qualidade da água de chuva, após filtração lenta, em relação à Portaria 518/04, do Ministério da Saúde, foi, em geral, satisfatória, porém, é necessária desinfecção para ser considerada potável. A taxa de radiação UV aplicada apresentou boa eficiência na remoção dos microorganismos estudados, tornando-a própria para consumo humano. / In the face of water scarcity problems in the present time, the use of alternative supply sources is cited as solution for the water conservation. Among these sources, the main is the rainwater catchment system, characterized by a simple and cheap solution to preserve drinking waters. In this context, this research promoted a characterization of the rainwater, making it possible a system of treatment of this water making viable the smallest operational demand possible, and thus, contributes to improve the quality of life of populations that do not have access to drinking waters with low impact possible to the environment. The present work establish the guidelines for the conception and elaboration of a project of water supply, where the treatment will be through Slow Filters and ultraviolet disinfection – keeping in mind that the chlorination, conventional method, demand a operational high cost, and also is rejected by some communities, because of the taste of the chlorinated water. The roofs of the building located in the “Parque Experimental do Núcleo Água” were utilized for the rainwater capitation, were constructed with metallic tile and, approximately, 180m ² of total projection area. Annex to the building was constructed a system of storage and treatment of the rainwater, is formed by two vertical slow filters and ultraviolet light bulbs. The characterization occurred through by 12 weekly physical-chemical analyses: temperature, pH, turbidity, true color, suspended solids, dissolved solids and total solids, acidity, alkalinity, hardness, chloride -the first three were carried out every day; and microbiological analyses, like: thermo tolerant and total coliforms and Escherichia coli. The rainwater was analyzed without treatment after passage through the slow filters with different filtration rates (4, 6 e 8 m3/m2 day), and after passage through ultraviolet disinfection with average of the 0,57 mW/cm2 . The rainwater analyzed can be classified according to CONAMA 357/05 is class 1 and according to NBR 12.216/92 is type B, being necessary in both classifications a treatment for the consumption. The quality of rainwater, after slow filtration, regarding Brazilian Ministry of Health Directive # 518/04, was, in general satisfactory, but is necessary the disinfection to be considered drinking water. The rate of ultraviolet radiation applied showed good efficacy for removal of microbiological studied in this research, being suitable for drinking.
26

Síntese otimizada de sistemas de cogeração e dessalinização

Ferreira, Eduardo Manfredini [UNESP] 05 June 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:40Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-06-05Bitstream added on 2014-06-13T20:46:41Z : No. of bitstreams: 1 ferreira_em_dr_guara_prot.pdf: 2582379 bytes, checksum: 9263a659ae78b3b2a0dfd7500e38a270 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A escassez da disponibilidade de água doce no mundo torna-se preocupante para os próximos anos e, apesar da crescente divulgação de tal situação, são poucas as pessoas que, na prática adotam uma postura consciente acerca da economia e uso racional do bem natural mais precioso existente. A presente tese apresenta uma proposta de produção de água potável a partir da água do mar pelo uso de processos de dessalinização associados a processos de cogeração, para que produzama energia térmica e elétrica para o funcionamento da instalação. A mesma é analisada com o uso de diferentes configurações, com vistas à otimização da instalação. São analisados 4 casos, verificando-se a viabilidade de sistemas de duplo propósito e sistemas híbridos, considerando-se, pelo lado do sistema de cogeração, a disputa entre diferentes conjuntos a gás de produção comercial, queimando gás natural ou biomassa gaseificada, com geradores de vapor, queimando óleo combustível ou biomassa in natura; pelo lado do sistema de dessalinização, concorrem unidades de osmose reversa acionadas térmica (ORS) ou eletricamente (ORE), unidades de evaporação (MED) e de destilação (MSF); no atendimento ás necessidades de vapor concorrem turbinas de contrapressão e condensação/extração. Foram analisados dados referentes à cidade litorânea de Ubatuba, SP, para avaliação do atendimento conjunto das necessidades de energia elétrica ee água potável para o abastecimento de situações limítrofes, como ocorre durante os picos de consumo de verão. Conclui-se que a proposta é viável para os casos analisados, podendo haver a possibilidade de venda de excedente energético, de acordo com o nível de produção da unidade como um todo. / World's fresh water availability scarcity is becoming a concerning problem day by day, and depende the increasing of the alarming new about such situation, just a few people adopt a positive position about the economy and rational use os this precious natural resource. This thesis presents a fresh water production proposal from seawater by desalination processes associated to cogeneration processes for producing the necessary thermal and electric energy for the whole installation. The dual-purpose systems is analyzed with the use of differente configurations by an optimization viewpoint. Four cases are analyzed with hybrid and dua purpose systems availability verification. The considerations, with respect to cogeneration were the use different commercial gas turbines, burning natural gas or gasified biomass, with or without steam generator, burning fuel oil or biomass in natura. For desalination system, it wasallowed the choice of reverse osmosi thermally driven (ROS) reverse osmosis elctrically driven (ROE), evaporation (MED) and distillation (MSF) units. Also, the steam supply system could be constituted of backpressure and extraction-condensation turbines. The data analyzed here refers to the Ubatuba coastal city, situated in the São Paulo Statte - Brazil, the relationship between the electrical energy and fresh water simultaneous supplying for extrem situations, like it occurs during summer consumption peaks was analyzed. The present study concluded that the analyzed cases were feasible, with the possibility of energetic surplus selling, according to the unit production operational level.
27

Avaliação da confiabilidade analítica de medições de turbidez em água potável

Marques, Guilherme Souza 15 August 2017 (has links)
Orientador : Prof. Dr. Jörg Wolfgang Metzger / Co-orientador : Profª. Drª. Karen Juliana do Amaral / Co-orientador : Prof. Dr. Gustavo Rafael Collere Possetti / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Mestrado Profissional em Meio Ambiente Urbano e Industrial, em parceria com o Serviço Nacional de Aprendizagem Industrial e a Universität Stuttgart. Defesa: Curitiba, 04/11/2016 / Inclui referências: f. 101-105 / Resumo: A qualidade da água distribuída à população apresenta impactos diretos na área da saúde. Ciente disso o Ministério da Saúde (MS), mediante a Portaria 2914/11, exige que os parâmetros de controle da água potável sejam determinados dentro de um sistema de qualidade nos moldes da NBR ISO/IEC 17025. Um dos itens de maior relevância nessa norma é a determinação da incerteza de medição, pois apresenta uma informação quantitativa sobre a confiabilidade de um resultado de medição. Um dos parâmetros de controle exigidos pela portaria do MS é a turbidez, que está diretamente ligada a garantia de um processo efetivo de desinfeção da água, tanto que o MS reduziu o valor máximo permissível (VMP) de 1,0 NTU para 0,5 NTU, e em determinados casos é exigido um VMP de 0,3 NTU. Nesse contexto, este trabalho se propõe a avaliar a confiabilidade analítica da medição da turbidez a partir da determinação da incerteza de medição de 11 padrões de formazina e 5 amostras de água para consumo humano, todos analisados em 6 turbidímetros diferentes provenientes de 3 fabricantes distintos: D, C e P. Para tanto desenvolveu-se o cálculo da incerteza de medição da turbidez com base no Guia para a Expressão da Incerteza de Medição e avaliou-se a capacidade analítica e a compatibilidade metrológica de cada turbidímetro. Dessa forma, identificaram-se as principais fontes de incerteza do processo de medição da turbidez e todas as equações necessárias para a sua determinação. Adicionalmente, desenvolveu-se uma ferramenta para auxiliar no cálculo da incerteza desse parâmetro, a qual fornece um certificado de calibração para o turbidímetro avaliado e define uma faixa de operação para o sistema de tratamento de água garantindo a conformidade da água produzida por ele em relação às exigências da Portaria 2914/11 do MS. A partir do cálculo de incerteza de medição verificou-se que a fonte que mais contribui para a incerteza de medição da turbidez é a curva de calibração. As maiores incertezas expandidas entre os padrões analisados, considerando um nível de 99,73%, apresentaram um valor médio de 0,05 NTU para os equipamentos de marca C, 0,11 NTU para os equipamentos da marca D e 0,44 NTU para o equipamento da marca P. Foi possível afirmar a compatibilidade metrológica entre os equipamentos da marca D e C em praticamente todos os resultados, ressalvando somente determinações abaixo de 0,1 NTU para o equipamento D1, onde essa afirmativa se torna duvidosa. Os resultados obtidos permitem afirmar que somente os equipamentos da marca C e D apresentam resultados com a confiabilidade analítica necessária para afirmar a conformidade da água potável em relação à turbidez. Palavras-chave: Turbidez. Cálculo de incerteza de medição. Confiabilidade analítica. GUM. Compatibilidade metrológica. Nefelometria. / Abstract: The quality of water distributed to the population has direct impacts on health. Aware of this, the Ministry of Health (MS), through Ordinance 2914/11, requires that the drinking water control parameters must be determined within a quality system along the lines of ISO / IEC 17025. One of the most relevant items in this standard is the determination of measurement uncertainty, because it presents quantitative information about the reliability of a measurement result. One of the control parameters required by MS is the turbidity, which is directly linked to ensure an effective process of disinfection of the water, so that the MS reduced the maximum permissible value (VMP) of 1.0 to 0.5 NTU, and in certain cases it required a VMP of 0.3 NTU. In this context, this study aims to evaluate the analytical reliability of the measurement of turbidity from the determination of the uncertainty of measurement of 11 formazin standards and 5 samples of water for human consumption, all analyzed in 6 different turbidimeters from 3 different manufacturers: D, C and P. Therefore was developed the calculation of the turbidity measurement uncertainty based on the Guide to the Expression of Uncertainty in Measurement and evaluated the analytical capacity and metrological compatibility of each turbidimeter. Thus, it were identified the main sources of uncertainty of the measurement process for turbidity and all the necessary equations for their determination. In addition, it was developed a tool to assist in the calculation of the uncertainty of this parameter, which provides a calibration certificate for the assessed turbidimeter and defines an operating range for the water treatment system to ensure compliance of the produced water regarding the requirements of MS Ordinance 2914/11. From the measurement uncertainty calculation it was found that the source that most contributes to the turbidity measurement uncertainty is the calibration curve. The greatest expanded uncertainty between the standards analyzed, considering a level of 99,73%, had an average of 0.05 NTU equipment for manufacturer C, 0,11 NTU for the equipment D brand and 0.44 NTU the equipment P. It was possible to affirm metrological compatibility of the brand D equipment and C in almost all results, excepting only determinations below 0.1 NTU for D1 equipment where this statement becomes doubtful. The results allow us to affirm that only the C and D brand equipment present results with the analytical reliability required to assert the conformity of drinking water regarding turbidity. Keywords: Turbidity. Measurement uncertainty calculation. Analytical reliability. GUM. Metrological compatibility. Nephelometry.
28

Desinfecção de agua para abastecimento com radiação ultravioleta : eficiencia bactericida e uma analise economica e energetica

Pires, Marco Roberto 14 May 1997 (has links)
Orientador: Roberto Feijo de Figueiredo, Gilberto De Martino Jannuzzi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-23T18:40:13Z (GMT). No. of bitstreams: 1 Pires_MarcoRoberto_M.pdf: 4765440 bytes, checksum: 68b559c8fd33a90d801120162c2d3e21 (MD5) Previous issue date: 1997 / Resumo: A desinfecção de água com radiação ultravioleta tem demonstrado ser uma alternativa à cloração. Os objetivos deste trabalho são: estudo da inativação dos microrganismos; análise' econômica do sistema de uv comparativamente a um sistema equivalente de desinfecção com cloro; e comparação do consumo de energia elétrica entre estes sistemas. Utilizou-se um reator (câmara de desinfecção), equipado com lâmpada de uv, operando no sistema de batelada. Os Microrganismos inativados foram E.coli, P.aeruginosa, A.hydrophila, E.faecalis e V.cholera. A análise econômica foi realizada em termos de implantação, operação e manutenção dos sistemas de cloro e uv com base nos preço de mercado. A comparação energética foi baseada na relação de volume de água desinfetada pelo consumo de energia elétrica entre os sistemas. A E.coli se mostrou o microrganismo de maior resistência inicial, mas a maior constante de inativação; o E.faecalis foi o mais resistente. O sistema de uv fornece água desinfetada a um custo de R$ 0,037 por habitante por ano. O consumo de energia elétrica entre os sistemas é equivalente para baixa dose de cloro. A radiação uv para desinfecção de água demonstra ser eficiente bactericida e compete economicamente com o cloro / Abstract: Ultraviolet radiation has been accepted as an altemative to chlorination for disinfection of water. The main subjects in this work can be summarized as follows: microorganism inactivation survey; comparative economical analysis between uv system and chlorine disinfection;comparative electrical energy consumption between them. A batch reactor, equipped with uv lamp, was used in the tests. E. coli, P.aeruginosa, A.hydrophila, E.faecalis, V.cholera, were the microorganisms employed for the study of inactivation. The economical analysis was accomplished based on capital costs, operation and maintenance of uv and chlorine system based on current market prices of components. The energetic analysis comparison was based on the volume ratio between disinfected water and electrical energy consumption of both the systems. The E.coli was the bacteria with the strongest initial resistance but the greatest inactivation constant. E.faecalis was the most resistant. The uv system provide disinfected water by R$ 0,037 per person per year. For low chlorine doses the electrical energy consumption between the two systems are equivalent. Finally, the work shows that uv radiation used for water disinfection is an important tool as an efficient bactericidal and that it competes economically with chlorination / Mestrado / Mestre em Planejamento de Sistemas Energéticos
29

Avaliação do emprego de areia de britagem como leito filtrante de filtros rápidos para tratamento de água / Evaluation of the use of crushed rock sand as filter bed for rapid filters applied for drinking water treatment

Silva, Bruno Moreno Ramos 20 February 2018 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2018-06-14T17:22:23Z No. of bitstreams: 1 texto completo.pdf: 15547903 bytes, checksum: 62aad1568da622fa84fb1ce0bf7d1b0f (MD5) / Made available in DSpace on 2018-06-14T17:22:23Z (GMT). No. of bitstreams: 1 texto completo.pdf: 15547903 bytes, checksum: 62aad1568da622fa84fb1ce0bf7d1b0f (MD5) Previous issue date: 2018-02-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo deste trabalho foi avaliar o emprego de areia de britagem como leito filtrante de filtros rápidos descendentes no tratamento de água para consumo humano. Testes preliminares em unidade de filtração de bancada (proveta de 2 L) indicaram: (i) que o leito de areia de britagem não afeta negativamente a qualidade da água filtrada (turbidez, pH e condutividade elétrica); (ii) elevado potencial de remoção de turbidez de água decantada; (iii) eficiência da retrolavagem para limpeza do leito filtrante. Na sequência, foram realizados ensaios em duas unidades piloto de filtração rápida (construídas em tubulação de acrílico com 19 cm de diâmetro interno e comprimento total de 267 cm): um com areia de britagem e outro, como unidade de controle, com areia natural de rio. Ambos os leitos filtrantes foram preparados com granulometria e profundidade de acordo com as especificações da norma da ABNT para filtração rápida com areia natural. As duas areias foram ainda caracterizadas em termos de: composição química, massa específica, densidade aparente, porosidade, solubilidade em ácido, potencial zeta dos grãos e coeficiente de esfericidade. Ao longo de quatro meses foram monitoradas 14 carreiras de filtração, as quais foram caracterizadas, para taxas de filtração de 180, 270 e 360 m3 m'2 d'1, em termos de: (i) duração das carreiras; (ii) perda de carga ao longo do leito filtrante; (iii) remoção de turbidez ao longo do leito filtrante; (iv) índices de filtrabilidade - Índice de Ives e Índice de Hudson. Em geral, o desempenho do filtro de areia de britagem foi similar ou superior ao filtro de areia natural, produzindo água filtrada com turbidez inferior a 0,50 uT ao longo de toda a carreira, com duração e desenvolvimento da perda de carga próximos aos do filtro de areia natural. Conclui- se que a areia de britagem apresenta elevado potencial de emprego como leito filtrante de filtros rápidos para o tratamento de água para consumo humano, sem desvantagens técnicas-operacionais e com atrativos ambientais / The objective of this work was to evaluate the use of crushed rock sand as a filter bed in rapid down flow filtration for drinking water treatment. Preliminary tests using a bench-scale filtration unit (2 L measuring cylinder) indicated: (i) that the crushed rock sand bed does not negatively affect the quality of the filtered water (turbidity, pH and electrical conductivity); (ii) a high potential for turbidity removal; (iii) backwashing is efficient in cleaning the filter bed. Then, trials were carried out using two pilot-scale rapid filtration units (acrylic tubes, internal diameter of 19 cm and total length of 267 cm): one with a crushed rock sand filter bed and the other (a control unit), with natural river sand. Both filter media were prepared in accordance with the Brazilian standards for rapid down flow sand filtration (particle size range and filter bed depth), and were further characterized in terms of: chemical composition, particles density, bulk density, porosity, acid solubility, zeta potential and sphericity coefficient. Over four months, 14 filter runs using filtration rates of 180, 270 and 360 m3.m'2.d'1 were monitored and characterized in terms of (i): filter run length; (ii) head loss increase along the filter bed depth; (iii) turbidity removal along the filter bed depth; (iv) filterability indexes - Ives Index and Hudson Index. Overall, the performance of the crushed rock sand filter was similar to or even better than that of the natural river sand filter, producing filtered water with turbidity lower than 0.50 NTU along the entire filter run, with duration and head loss increasing rates similar to those of the natural sand filter. It is concluded that crushed rock sand presents a high potential for use as a filter media for rapid filtration in drinking water treatment, with environmental advantages and no technical or operational disadvantages.
30

Modelo para tomada de decisão entre a produção de água não potável em edifícios e a produção de água potável pelo Sistema Produtor São Lourenço. / Decision making model between the non-potable water production in buildings and the drinking water production by the São Lourenço Producer System.

Patucci, Renato Augusto 17 May 2019 (has links)
O adensamento populacional que as metrópoles vivenciam contribui para reduzir a disponibilidade específica de água, medida em m³/hab.ano. Adicionalmente a este evento, quando o crescimento urbano ocorre de forma não planejada, isso impacta também a qualidade dos mananciais. Esses dois efeitos ocorrem de forma combinada, sobretudo na Região Metropolitana de São Paulo (RMSP). Como consequência observam-se opções de ampliação da capacidade de produção de água potável sucessivamente mais custosas, seja por processos mais caros para o tratamento de um manancial mais poluído, próximo ao centro consumidor, seja pela maior distância de um manancial não poluído, e maiores custos com obras, como ocorre atualmente na implantação do Sistema Produtor São Lourenço (SPSL). Esse processo de encarecimento das opções para ampliação do sistema centralizado de produção de água potável persistirá na RMSP, conforme a população continue a aumentar nas próximas décadas. Existem fontes alternativas com disponibilidade satisfatória, como a água residuária, que quando adequadamente tratadas, podem ser direcionadas para usos que não demandam água potável. Essa possibilidade tem sido aproveitada de forma crescente pelo mercado imobiliário em edifícios, através da instalação de sistemas prediais de água não potável (SPANP), e há diferentes tecnologias disponíveis se consolidando com custos em tendência de queda. Nesse contexto, o objetivo da pesquisa é formular um modelo matemático de tomada de decisão para verificar se a utilização de SPANP são viáveis em relação à implantação do SPSL. Para o desenvolvimento da pesquisa, realizou-se revisão bibliográfica para avaliar as experiências de implantação de SPANP com fonte de águas cinzas em diferentes localidades, bem como para estabelecer a comparação de produção de água potável em macroescala em relação à produção de água não potável em microescala. Foram coletados dados quanto aos custos de construção, operação e manutenção de um SPANP em operação em um edifício na RMSP, e o mesmo para o SPSL. Por meio dos princípios da Programação Inteira, foi formulado um modelo para a indicação de qual opção de sistema apresenta o menor custo total acumulado durante os 20 primeiros anos de operação. Foram simulados cinco cenários com a alteração das principais variáveis que influenciam o comportamento da viabilidade das opções, sendo que as simulações foram realizadas com o uso do software LINDOTM. Em quatro dos cinco cenários simulados, o SPSL foi a opção de menor custo acumulado no 20o ano de operação, indicando a maior probabilidade do mesmo ser a opção de implantação mais econômica no presente. No entanto, devido à tendência de encarecimento das alternativas de ampliação do sistema centralizado de produção de água potável e de redução de custos dos SPANP, essa conclusão não pode ser adotada automaticamente quanto ao próximo sistema centralizado de água potável planejado para ser implantado. / The population agglomeration phenomenon that the metropolises pass through, reduces the water availability measured by the indicator m³/hab.year. Additionally, when urban growth happen in an unplanned way, it also impacts the quality of the water sources. These two effects occur in a combined way, especially in the São Paulo Metropolitan Region (SPMR). As a consequence, the options for expanding the production capacity of drinking water are successively more costly, either by more expensive processes for the treatment of a more polluted source, near the consumer center, or by the larger distance of an unpolluted source, and higer costs with construction, as it is currently happening in the implementation of the São Lourenço Producer System (SLPS). The process that is turning expensive the options for expanding the centralized drinking water system will persist in the SPMR as the population continues to increase in the coming decades. There are alternative sources with satisfactory availability, such as wastewater, which when properly treated, can be directed to uses that do not require potable water. This possibility has been used more and more by the real estate market in buildings, through the installation of non-potable water systems (NPWS), and there are different technologies available in consolidation with falling costs. Thus, the objective of the research is to formulate a mathematical decision making model to verify if the use of NPWS are viable in relation to the implementation of the SLPS. For the development of the research, a bibliographical review was carried out to evaluate the experiences of implementation of NPWS with source of gray water in different localities, as well as to establish the comparison of production of drinking water in macro scale in relation to the production of non-potable water in micro scale. Data were collected on the costs of construction, operation and maintenance of NPWS in a building in the SPMR, and the same for SLPS. Through the principles of Integer Programming, a model was formulated to indicate which system option has the lowest accumulated total cost during the first 20 years of operation. Five scenarios were simulated with the change of the main variables that influence the viability behavior of the options, the simulations were performed using LINDOTM software. In four of the five simulated scenarios, SLPS was the lowest accumulated cost option in the 20th year of operation, indicating that it is more likely to be the most economical deployment option in the present. However, due to the rising cost of alternatives for the expansion of the centralized drinking water production system and the cost reduction of NPWSs, this conclusion cannot be automatically adopted for the next centralized drinking water system planned to be implemented.

Page generated in 0.0279 seconds