• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 14
  • 13
  • 11
  • 10
  • 10
  • 8
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo da aderência aço-concreto em pilares mistos preenchidos / Study of bond on concrete-filled steel tubes

Silva, Romulo Dinalli da 10 March 2006 (has links)
Este trabalho aborda o estudo da aderência aço-concreto em pilares mistos preenchidos através de revisão bibliográfica e de investigação experimental. De modo esquemático, a aderência é dividida em três parcelas: adesão, aderência mecânica e atrito, que em conjunto compõem a aderência natural. Adicionalmente, podem ser empregados conectores de cisalhamento, que são dispositivos mecânicos fixados nas superfícies internas dos tubos, como meio de ampliar a resistência ao escorregamento. Foram realizados ensaios do tipo pushout em alguns tipos de modelos de pilar preenchido: modelos simples, com adição de conectores tipo pino com cabeça, com cantoneiras na interface aço-concreto e semelhantes aos anteriores mais elementos de ligação. Com os resultados obtidos traçaram-se comportamentos força x escorregamento do concreto, força x deformações axiais nos materiais e curvas de distribuição de força ao longo do comprimento dos modelos. Concluiu-se que conectores tipo pino com cabeça e cantoneiras são uma excelente alternativa como dispositivos auxiliares na transferência de tensões de cisalhamento na interface aço-concreto. Entretanto, é necessário garantir resistência à ligação para que esses mecanismos sejam mobilizados / This research presents a study of influence of bond on concrete-filled steel tubes by means of a bibliography review and an experimental investigation. The bond strength counts on three mechanisms: adhesion of the concrete to the steel surface, friction and wedging of the concrete core. In order to improve the shear resistance of the steel-concrete interface, shear connectors can be used. A series of push-out tests of rectangular concrete-filled steel tubes was conducted in the specimens without mechanical shear connectors, specimens with stud bolt shear connectors and specimens with angles. They were also tested the corresponding beam-column connections. The results are shown in curves force x slip of concrete, force x axial strain of materials and distribution of axial load to the steel and to the concrete. The results of the tests permitted identify the mechanisms of natural bond and indicated that the stud bolts and the angles are excellent alternatives as auxiliary mechanisms to transfer shear between the concrete and steel in the concrete filled composite column. However, it is necessary to guarantee the connection enough strength in order to permit these resistance be developed
2

Projeto e construção de pilares mistos aço-concreto / Steel-concrete composite columns: design and building

Figueiredo, Luciana Maria Bonvino 14 May 1998 (has links)
Um pilar misto aço-concreto consiste basicamente de um elemento de aço, simples ou composto, predominantemente comprimido, que trabalhe em conjunto com o concreto simples ou armado. Há basicamente dois tipos de pilar misto: os revestidos e os preenchidos. Os revestidos são formados por um perfil de aço embutido em uma seção de concreto, garantindo a proteção ao fogo (havendo necessidade de armaduras). Os pilares preenchidos são tubos de aço, circulares ou retangulares, preenchidos com concreto, dispensando qualquer tipo de armadura e a necessidade do uso de formas; porém para proteger do fogo e da corrosão exige-se um tratamento \"extra\" do tubo de aço. A norma brasileira NBR 8800/86 - \"Projeto e execução de estruturas de aço de edifícios\" quanto as estruturas mistas se dedica apenas àquelas submetidas à flexão simples (vigas mistas), não abordando as estruturas basicamente comprimidas (pilares mistos). Já as normas LRFD-AISC/86 - \"Load and resistance factor design\", Eurocode 4, BS 5400 apresentam considerações específicas sobre o dimensionamento de barras axialmente comprimidas e flexo-comprimidas, tratando tanto dos elementos revestidos quanto dos preenchidos. Do ponto de vista estrutural, são analisadas e discutidas as prescrições das principais normas estrangeiras aplicáveis. Quanto aos aspectos construtivos, apresentam-se técnicas de execução e de acabamento, dando especial atenção a questão da resistência ao fogo. / A composite column may be defined as a member made of a structural steel section, basicaly under compression, working with simple or reinforced concrete. There are basically two kinds of steel-concrete composite columns: structural steel section encased in concrete which has fire protection and it is necessary to use reinforcement and tubes filled with concrete which it is not necessary to use reinforcement and formwork but it require an extra protection to fire. Steel Brazilian code NBR 8800/86 - \"Projeto e execução de estruturas de aço de edifícios\" give specifications only for steel-concrete member under bending (composite beams). This code neglegence composite members under compression (composite columns). LRFD-AISC/86 - \"Load and resistance factor design\", Eurocode 4, BS 5400 give specifications about steel-concrete composite columns under compression and bending combined to concrete encased composite columns and steel tubes filled with concret. Codes requirements, constructional aspects and fire behaviour of composite columns are presented and discussed.
3

Estudo teórico-experimental de pilares mistos compostos por tubos de aço preenchidos com concreto de alta resistência. / Theoretical and experimental study of high strength concrete filled steel tubes

De Nardin, Silvana 25 March 1999 (has links)
O emprego de pilares mistos formados por tubos de aço preenchidos com concreto de alta resistência, sobretudo em edifícios altos, é uma tendência em diversos países europeus, americanos e asiáticos. A tais elementos são atribuídas vantagens como: alta resistência e ductilidade, economia de materiais e mão-de-obra, redução das dimensões da seção transversal e melhoria no comportamento dos materiais aço e concreto, devido ao efeito de confinamento. Buscando suprir algumas carências de conhecimento, procura-se obter dados experimentais sobre o comportamento de pilares mistos axialmente comprimidos, possibilitando desta forma avaliar parâmetros como influência da forma da seção transversal e da espessura do perfil tubular no seu comportamento. Foram analisadas seções quadradas, circulares e retangulares, preenchidas por concreto com resistência média de 50MPa. A ruína destes elementos caracterizou-se pelo esmagamento do concreto, ocorrendo posteriormente a flambagem local do perfil em diversos pontos. A capacidade resistente prevista por diversas normas resultou em valores muito próximos dos experimentais, embora várias destas normas não considerem o efeito de confinamento. Os ensaios mostraram que o efeito de confinamento contribui de forma decisiva na melhoria do comportamento dos materiais, sobretudo ductilizando o concreto de alta resistência, entretanto seus efeitos não são significativos no aumento da capacidade resistente da seção mista. Alguns critérios para avaliação da ductilidade à compressão foram adaptados e mostraram bons resultados, possibilitando o cálculo do índice de ductilidade. / The use of concrete filled steel tubes especially in tall buildings is a tendency in several european, american and asian countries. The use of these members has several advantages: high resistance and ductility, saving of materials and labour, reduction of cross section dimensions and improvement in behaviour of the materials steel and concrete due the confinement. The main purpose of this study is provide some experimental results of the behaviour of concrete filled steel tubes concentrically loaded. The main experimental parameters considered were the influence of the cross-section shape and thickness of steel tube. Square, circular and rectangular cross-section shapes infilling with concrete of the 50MPa of strength were analyzed. The failure was characterized for crushing of the concrete and later local buckling of the steel section in several points. The strength capacity predicted for several standards showed good agreement with the experimental failure values although this does not consider the confinement of the concrete. The results of tests showed that the confinement effect contributes for improvement behaviour of materials, especially increasing the ductility of the high strength concrete. However the results showed that the triaxial confinement does not increase the axial capacity of the concrete filled steel tubes. Some methods to estimate the ductility of axially compressed concrete columns were adapted and showed good results permitting the calculation of the ductility index of short columns.
4

Análise teórico-experimental de pilares mistos preenchidos de seção circular / Theoretical and experimental analysis of circular concrete-filled steel tubular columns

Oliveira, Walter Luiz Andrade de 06 June 2008 (has links)
Os pilares mistos preenchidos são elementos estruturais constituídos por um tubo de aço preenchido com concreto de qualidade estrutural. O objetivo principal do trabalho foi estudar o comportamento dos pilares mistos preenchidos de seção circular. Para isso, foi avaliada a influência da resistência à compressão do concreto (fc), da esbeltez do pilar (L/D), da espessura do tubo de aço (t) e da forma de introdução do carregamento, se no núcleo de concreto ou na seção mista do pilar. Foram feitos ensaios experimentais de 64 pilares mistos preenchidos, submetidos à força de compressão centrada. Os resultados de capacidade resistente obtidos foram avaliados e comparados com os resultados de previsão segundo os procedimentos normativos estrangeiros do EUROCODE 4:2004, ANSI/AISC:2005 e CAN/CSA:2001 e do Projeto de Revisão da Norma Brasileira (PR-NBR 8800, draft 2008). Os resultados previstos foram maiores que os experimentais para os procedimentos do ANSI/AISC e da NBR e menores para os procedimentos do EC4 e do CAN/CSA. A partir da comparação dos valores de capacidade resistente experimentais e normativos, foi desenvolvido um estudo de confiabilidade dos valores de força resistente obtidos segundo as equações de dimensionamento dessas normas, por meio da estimativa do erro de modelo inerente a cada uma. Os resultados mostraram que o EC4 apresenta os índices de confiabilidade mais uniformes. Além disso, foi feita uma modelagem numérica dos pilares mistos preenchidos com relação L/D = 10, buscando obter o valor da capacidade resistente desses pilares e compará-los com os resultados experimentais. Embora o modelo numérico tenha representado adequadamente o comportamento dos pilares preenchidos esbeltos, os valores de força última foram inferiores aos experimentais. / Concrete-filled steel tubular columns are structural elements made of a steel tube filled with structural concrete. The main objective of this work was study the global behavior of concrete-filled steel tubular columns. For this, some variables were evaluated: concrete compressive strength (fc), length-to-diameter ratio (L/D), diameter-to-thickness ratio (D/t) and the type of load application (on concrete core or on composite cross section). Tests of 64 concrete filled columns were performed. The columns were subjected to axial load. The results of experimental compressive strength were compared to results from three different international codes (EUROCODE 4:2004, ANSI/AISC:2005 e CAN/CSA:2001) and the national NBR 8800, draft 2008. The results showed, in general, a conservative behavior of values predicted by NBR and ANSI/AISC e non-conservative values by EC4 and CAN/CSA. Based on comparisons between experimental values and codes predictions, an error model variable was estimated to each code and a reliability analysis was performed. The results indicate that the EC4 is the best code with less tendentious behavior of its design equation. A numerical analysis of columns with slenderness (L/D) equal to 10 was carried out to try to predict the peak load of columns and compare the results with those from experimental analysis. Althougth the results of the numerical analysis had a good match to the experimental ones, the values, in average, were conservatives.
5

Estudo teórico-experimental do efeito da laje na transferência de forças em ligações viga-pilar misto preenchido / Experimental and theorical analysis of slab effect on the force transfer strength of steel beam to concrete filled columns connection

Farias, Rômulo da Silva 07 May 2008 (has links)
Este trabalho tem como objetivo analisar a influência da laje de concreto armado em uma ligação viga-pilar misto mediante um estudo experimental e uma modelagem numérica. A ligação considerada é constituída por uma viga de aço unida a um pilar misto preenchido através de barras rosqueadas que trabalham como parafusos passantes. Esse tipo de ligação já foi investigado em trabalhos anteriores, mediante análise experimental em modelos que não incluíam a laje, resultando em uma indesejável ruptura dos parafusos. A análise da ligação completa, com a presença da laje de concreto tornando a ligação uma ligação mista, além de ser mais realista, melhora as características de resistência e rigidez do modelo, além de tornar mais dúctil o seu comportamento. Para isso foram analisados três modelos experimentais que se diferenciam pela ausência ou tipo de conector de cisalhamento presente na região interna do pilar misto. Os resultados obtidos mostraram que a ruptura da ligação passou a ser determinada pela laje, associada ao escoamento da armadura longitudinal sem que a ligação viga-pilar fosse comprometida. Para a análise numérica foi utilizado o pacote computacional DIANA®, baseado no método dos elementos finitos. Os modelos numéricos foram desenvolvidos e calibrados pelos resultados experimentais, produzindo resultados bastante satisfatórios. Finalmente foi realizada uma análise numérica paramétrica variando a armadura longitudinal da laje e a resistência do concreto com o objetivo de se entender melhor a influência desses parâmetros no comportamento da ligação investigada. / The main objective of this work was to analyze the contribution of the concrete slab for the behavior of a steel beam-concrete filled composite column connection through an experimental program and also a numerical modeling. The considered connection was constituted of steel beams connected to a concrete filled tubular column of rectangular cross section by means of passing bars. This type of connection was studied before through an experimental analysis of connections that did not include the slab, resulting in failure of the passing bars. In the present study, the presence of the slab is considered, turning the connection a composite one. The studied model is more representative of the real structure, and also improves the resistance and the stiffness of the connection, turning the behavior more ductile. Three specimens were tested, where the studied variable was the type of shear connector, angles or stud-bolts, and one specimen without connectors as a reference. The obtained results showed that the failure was determined by the slab, associated to the yielding of the longitudinal reinforcement, without affecting the beam column connection. The finite element based software DIANA® was used to the numerical analysis. The numerical models were developed and calibrated by the experimental results, producing a good agreement. Finally, a parametric analysis was done, varying the slab longitudinal reinforcement and the concrete strength in order to better understand the influence of these parameters in the behavior of the studied connection.
6

CONTRIBUIÇÃO DOS PAINÉIS DE ALVENARIA NA ANÁLISE DE PÓRTICOS DE CONCRETO ARMADO / CONTRIBUTION OF MASONRY PANELS ON ANALYSIS OF REINFORCED CONCRETE FRAMES

Silva, Liriane Reis da 21 March 2014 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / In this paper, a study on masonry infilled reinforced concrete (RC) frames subjected to service limit state horizontal loads is presented, considering the masonry panel contribution in the stiffness of the structure. The analysis of infilled frames is performed in two ways: using the equivalent diagonal strut concept, called here as macromodelling and the finite element method (FEM) for the micromodelling. Due to simplicity, equivalent strut models are really attractive for the inclusion of masonry panels in structural models of buildings frames. However, formulations available in the literature provide substantially distinct values for determining the axial rigidity of the equivalent strut, and disregarding some important parameters of the structural behavior of the infilled frame. In the FEM analysis, numerical simulations of infilled RC frames are done, with and without openings, with different spans, stiffness of the columns and masonry properties, using finite elements type shell in the modeling, in addition to the consideration of the contact frame-masonry. The simulations results allow the assessment of the limitations of the existing formulations for determining the width of the diagonal strut. In infilled frames with openings of doors and windows, is evaluated how the size and position of the aperture affects the stiffness of the structure. Finally, the maximum stresses (tensile, compression and shear) of all models are evaluated and compared with their respective resistant stresses in order to determine the possibility of cracking of the masonry panels of frames subjected to service limit state actions. / Neste trabalho é apresentado um estudo sobre pórticos de concreto armado preenchidos com alvenaria submetidos a ações horizontais de Estado Limite de Serviço (ELS), considerando a contribuição do painel de preenchimento na rigidez da estrutura. A análise dos pórticos preenchidos é realizada de duas maneiras: empregando-se o conceito da diagonal equivalente, na denominada macromodelagem e o método dos elementos finitos (MEF) para a micromodelagem simplificada. Em razão da simplicidade, os modelos com barras diagonais equivalentes são bastante atrativos para a inclusão de painéis de alvenaria nos modelos estruturais de pórticos de edifícios. Entretanto, as formulações disponíveis na bibliografia especializada fornecem valores sensivelmente distintos para a determinação da rigidez axial da barra equivalente, além de desconsiderarem alguns parâmetros importantes do comportamento estrutural do conjunto pórtico-alvenaria. Na análise através do MEF são realizadas simulações numéricas de pórticos de concreto preenchidos com alvenaria, com e sem aberturas, com diferentes vãos, rigidez de pilares e propriedades da alvenaria, empregando-se elementos bidimensionais na modelagem, além da consideração do contato pórtico-parede. Os resultados dessas simulações permitem a avaliação das limitações das formulações existentes para a determinação da largura da barra equivalente. No caso de pórticos preenchidos com aberturas, é avaliado de que forma o tamanho e a posição da abertura afeta a rigidez da estrutura. Por fim, as máximas tensões solicitantes (tração, compressão e cisalhamento) de todos os modelos são avaliadas, e comparadas com as respectivas tensões resistentes, a fim de determinar a possibilidade de fissuração dos painéis de preenchimento de pórticos submetidos a ações de ELS.
7

Avaliação de pórticos planos de aço considerando a contribuição da alvenaria pelo modelo de bielas e tirantes / Evaluation of steel plane frames considering the contribution of the masonry through the strut-and-tie model

Silva, Rafael Lopes e 04 July 2011 (has links)
Made available in DSpace on 2015-03-26T13:28:03Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2387307 bytes, checksum: f11d179178c73973dbcc9eaba047425e (MD5) Previous issue date: 2011-07-04 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work presents an evaluation of the structural behavior of steel plane frames infilled with structural masonry of blocks of autoclaved aerated concrete, regarding the contribution of the masonry to the structure global stiffening, through the strut-and-tie model. Case studies were evaluated taking into account three steel plane frames and, subsequently, the model was applied to the project of steel buildings with four, six, and eight stories. First and second-order numerical analyses (nonlinear geometrical analysis) were performed to braced steel frames with bracing elements formed for bars of steel and masonry panels. The masonry panels were considered across strut-and-tie model. It is presented comparisons of the lateral displacements and the solicitant forces in the bars of strut-and-tie model to first and second-order analyses. The solicitant forces on the strut and tie were also compared to the structural resistance on these bars aiming to achieve the structural dimension of the masonry panel. Through the results obtained it is concluded that it is possible to substitute the bracing metal bars for the masonry panels until determined numbers of stories. This numbers depends on factors such as the stiffness of the frame and masonry panels, and the intensity applied. / Neste trabalho apresenta-se uma avaliação do comportamento estrutural de pórticos planos de aço preenchidos com alvenaria estrutural de blocos de concreto celular autoclavado, considerando a contribuição da alvenaria na rigidez global da estrutura, por meio de um modelo de bielas e tirantes. Para realização dos estudos de caso, foram avaliados três pórticos planos de aço e, posteriormente, o modelo foi aplicado ao projeto de edifícios de aço com quatro, seis e oito pavimentos. Foram realizadas análises numéricas de primeira e segunda ordem (análise não-linear geométrica) de pórticos de aço contraventados com elementos de contraventamentos formados por barras de aço e por painéis de alvenaria. Os painéis de alvenaria foram considerados por meio do modelo de bielas e tirantes. São apresentadas comparações dos deslocamentos laterais e dos esforços solicitantes nas barras do modelo de bielas e tirantes para as análises de primeira e de segunda ordem. Os esforços solicitantes nas bielas e nos tirantes também foram comparados com os esforços resistentes nessas barras, com vistas a efetuar o dimensionamento estrutural do painel de alvenaria. Os resultados obtidos permitem concluir que é possível substituir as barras de contraventamento metálico por painéis de alvenaria até um determinado número de pavimentos. Este número depende de fatores como a rigidez dos pórticos e dos painéis de alvenaria e a intensidade das ações aplicadas.
8

Estudo teórico-experimental de pilares mistos compostos por tubos de aço preenchidos com concreto de alta resistência. / Theoretical and experimental study of high strength concrete filled steel tubes

Silvana De Nardin 25 March 1999 (has links)
O emprego de pilares mistos formados por tubos de aço preenchidos com concreto de alta resistência, sobretudo em edifícios altos, é uma tendência em diversos países europeus, americanos e asiáticos. A tais elementos são atribuídas vantagens como: alta resistência e ductilidade, economia de materiais e mão-de-obra, redução das dimensões da seção transversal e melhoria no comportamento dos materiais aço e concreto, devido ao efeito de confinamento. Buscando suprir algumas carências de conhecimento, procura-se obter dados experimentais sobre o comportamento de pilares mistos axialmente comprimidos, possibilitando desta forma avaliar parâmetros como influência da forma da seção transversal e da espessura do perfil tubular no seu comportamento. Foram analisadas seções quadradas, circulares e retangulares, preenchidas por concreto com resistência média de 50MPa. A ruína destes elementos caracterizou-se pelo esmagamento do concreto, ocorrendo posteriormente a flambagem local do perfil em diversos pontos. A capacidade resistente prevista por diversas normas resultou em valores muito próximos dos experimentais, embora várias destas normas não considerem o efeito de confinamento. Os ensaios mostraram que o efeito de confinamento contribui de forma decisiva na melhoria do comportamento dos materiais, sobretudo ductilizando o concreto de alta resistência, entretanto seus efeitos não são significativos no aumento da capacidade resistente da seção mista. Alguns critérios para avaliação da ductilidade à compressão foram adaptados e mostraram bons resultados, possibilitando o cálculo do índice de ductilidade. / The use of concrete filled steel tubes especially in tall buildings is a tendency in several european, american and asian countries. The use of these members has several advantages: high resistance and ductility, saving of materials and labour, reduction of cross section dimensions and improvement in behaviour of the materials steel and concrete due the confinement. The main purpose of this study is provide some experimental results of the behaviour of concrete filled steel tubes concentrically loaded. The main experimental parameters considered were the influence of the cross-section shape and thickness of steel tube. Square, circular and rectangular cross-section shapes infilling with concrete of the 50MPa of strength were analyzed. The failure was characterized for crushing of the concrete and later local buckling of the steel section in several points. The strength capacity predicted for several standards showed good agreement with the experimental failure values although this does not consider the confinement of the concrete. The results of tests showed that the confinement effect contributes for improvement behaviour of materials, especially increasing the ductility of the high strength concrete. However the results showed that the triaxial confinement does not increase the axial capacity of the concrete filled steel tubes. Some methods to estimate the ductility of axially compressed concrete columns were adapted and showed good results permitting the calculation of the ductility index of short columns.
9

Estudo teórico-experimental do efeito da laje na transferência de forças em ligações viga-pilar misto preenchido / Experimental and theorical analysis of slab effect on the force transfer strength of steel beam to concrete filled columns connection

Rômulo da Silva Farias 07 May 2008 (has links)
Este trabalho tem como objetivo analisar a influência da laje de concreto armado em uma ligação viga-pilar misto mediante um estudo experimental e uma modelagem numérica. A ligação considerada é constituída por uma viga de aço unida a um pilar misto preenchido através de barras rosqueadas que trabalham como parafusos passantes. Esse tipo de ligação já foi investigado em trabalhos anteriores, mediante análise experimental em modelos que não incluíam a laje, resultando em uma indesejável ruptura dos parafusos. A análise da ligação completa, com a presença da laje de concreto tornando a ligação uma ligação mista, além de ser mais realista, melhora as características de resistência e rigidez do modelo, além de tornar mais dúctil o seu comportamento. Para isso foram analisados três modelos experimentais que se diferenciam pela ausência ou tipo de conector de cisalhamento presente na região interna do pilar misto. Os resultados obtidos mostraram que a ruptura da ligação passou a ser determinada pela laje, associada ao escoamento da armadura longitudinal sem que a ligação viga-pilar fosse comprometida. Para a análise numérica foi utilizado o pacote computacional DIANA®, baseado no método dos elementos finitos. Os modelos numéricos foram desenvolvidos e calibrados pelos resultados experimentais, produzindo resultados bastante satisfatórios. Finalmente foi realizada uma análise numérica paramétrica variando a armadura longitudinal da laje e a resistência do concreto com o objetivo de se entender melhor a influência desses parâmetros no comportamento da ligação investigada. / The main objective of this work was to analyze the contribution of the concrete slab for the behavior of a steel beam-concrete filled composite column connection through an experimental program and also a numerical modeling. The considered connection was constituted of steel beams connected to a concrete filled tubular column of rectangular cross section by means of passing bars. This type of connection was studied before through an experimental analysis of connections that did not include the slab, resulting in failure of the passing bars. In the present study, the presence of the slab is considered, turning the connection a composite one. The studied model is more representative of the real structure, and also improves the resistance and the stiffness of the connection, turning the behavior more ductile. Three specimens were tested, where the studied variable was the type of shear connector, angles or stud-bolts, and one specimen without connectors as a reference. The obtained results showed that the failure was determined by the slab, associated to the yielding of the longitudinal reinforcement, without affecting the beam column connection. The finite element based software DIANA® was used to the numerical analysis. The numerical models were developed and calibrated by the experimental results, producing a good agreement. Finally, a parametric analysis was done, varying the slab longitudinal reinforcement and the concrete strength in order to better understand the influence of these parameters in the behavior of the studied connection.
10

Projeto e construção de pilares mistos aço-concreto / Steel-concrete composite columns: design and building

Luciana Maria Bonvino Figueiredo 14 May 1998 (has links)
Um pilar misto aço-concreto consiste basicamente de um elemento de aço, simples ou composto, predominantemente comprimido, que trabalhe em conjunto com o concreto simples ou armado. Há basicamente dois tipos de pilar misto: os revestidos e os preenchidos. Os revestidos são formados por um perfil de aço embutido em uma seção de concreto, garantindo a proteção ao fogo (havendo necessidade de armaduras). Os pilares preenchidos são tubos de aço, circulares ou retangulares, preenchidos com concreto, dispensando qualquer tipo de armadura e a necessidade do uso de formas; porém para proteger do fogo e da corrosão exige-se um tratamento \"extra\" do tubo de aço. A norma brasileira NBR 8800/86 - \"Projeto e execução de estruturas de aço de edifícios\" quanto as estruturas mistas se dedica apenas àquelas submetidas à flexão simples (vigas mistas), não abordando as estruturas basicamente comprimidas (pilares mistos). Já as normas LRFD-AISC/86 - \"Load and resistance factor design\", Eurocode 4, BS 5400 apresentam considerações específicas sobre o dimensionamento de barras axialmente comprimidas e flexo-comprimidas, tratando tanto dos elementos revestidos quanto dos preenchidos. Do ponto de vista estrutural, são analisadas e discutidas as prescrições das principais normas estrangeiras aplicáveis. Quanto aos aspectos construtivos, apresentam-se técnicas de execução e de acabamento, dando especial atenção a questão da resistência ao fogo. / A composite column may be defined as a member made of a structural steel section, basicaly under compression, working with simple or reinforced concrete. There are basically two kinds of steel-concrete composite columns: structural steel section encased in concrete which has fire protection and it is necessary to use reinforcement and tubes filled with concrete which it is not necessary to use reinforcement and formwork but it require an extra protection to fire. Steel Brazilian code NBR 8800/86 - \"Projeto e execução de estruturas de aço de edifícios\" give specifications only for steel-concrete member under bending (composite beams). This code neglegence composite members under compression (composite columns). LRFD-AISC/86 - \"Load and resistance factor design\", Eurocode 4, BS 5400 give specifications about steel-concrete composite columns under compression and bending combined to concrete encased composite columns and steel tubes filled with concret. Codes requirements, constructional aspects and fire behaviour of composite columns are presented and discussed.

Page generated in 0.0472 seconds