531 |
Avaliação da biocompatibilidade de diamantes microestruturados e nanoestruturados : ensaios " in vitro" e "in vivo" / Evaluation the biocompatibility of microcrystalline and nanocrystallime diamond: "in vitro" and "in vivo" assaysRodrigues, Ana Amélia 30 August 2006 (has links)
Orientador: Vitor Baranauskas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-08-09T14:59:50Z (GMT). No. of bitstreams: 1
Rodrigues_AnaAmelia_M.pdf: 19209454 bytes, checksum: 1a2efefc090d27e2715b48aad097989d (MD5)
Previous issue date: 2006 / Resumo: O desenvolvimento de novos materiais para a produção de implantes ortopédicos tem sido uma busca constante, devido principalmente ao aumento das aplicações clínicas e à necessidade de se alcançar maior durabilidade, diminuindo assim as cirurgias de revisão. O diamante CVD obtido por deposição química da fase vapor é um novo material com grande potencial de uso devido às suas excelentes propriedades físico-químicas. Dentre elas pode-se destacar a inércia química, extrema dureza e baixo coeficiente de atrito, características importantes para materiais que necessitam resistir ao desgaste e à corrosão
produzida pelos fluídos do corpo humano. O objetivo deste estudo foi avaliar pela análise ¿in vitro¿ e ¿in vivo¿ a biocompatibilidade de tubos de diamante microcristalino e diamante nanocristalino produzidos pela deposição química de vapor em filamento quente
(CVD). Palavras Chave: diamante CVD, biomateriais, implantes, próteses / Abstract: The development of new materials for orthopedic implants has been a quest due to the increasing number of clinical applications and necessity of achieving larger durability for lessening the need for revision surgeries. Diamond CVD (Chemical Vapour Deposition) is a new material with larger potential of future use due its excellent physico-chemical properties like for instance, high chemical inertness, extreme hardness and low friction coefficient. The aim of this study is to evaluate by ¿in vitro¿ and ¿in vivo¿ assays the biocompatibility of microcrystalline and nanocrystalline diamond self-sustaining tubes produced by hot-filament chemical vapor deposition (CVD).
Key Words: chemical-vapor-deposited diamond, biomaterials, implants, prosthesis / Mestrado / Engenharia de Computação / Mestre em Engenharia Elétrica
|
532 |
Efeito do tipo de revestimento estetico e da eletroerosão sobre a desadaptação de infra-estruturas implanto-suportadas fundidas em titanio c.p. / The influence of the veneering application and Spark erosion on the misfit level of implant-supported frameworksNakaoka, Marcia Mika 22 June 2007 (has links)
Orientador: Marcelo Ferraz Mesquita / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T19:46:50Z (GMT). No. of bitstreams: 1
Nakaoka_MarciaMika_D.pdf: 1091285 bytes, checksum: 76d1bd5bef1fb0bee757a9f929be3f3a (MD5)
Previous issue date: 2007 / Resumo: As distorções oriundas das técnicas de aplicação de revestimentos estéticos sobre infra-estruturas metálicas de próteses fixas podem resultar em margens cervicais desadaptadas. Dessa forma, este trabalho propôs-se a avaliar o efeito do tipo de revestimento estético, da simulação dos ciclos de cocção da cerâmica, e da aplicação da eletroerosão, sobre o desajuste de infra-estruturas implanto-suportadas fundidas em titânio comercialmente puro (Ti c.p.). Foi utilizada uma matriz metálica contendo 5 pilares intermediários do tipo Microunit. Sobre ela, foram enceradas 40 infra-estruturas,
posteriormente fundidas em Ti c.p. (Tritan, Dentaurum, Alemanha). Para cada infraestrutura foi confeccionado um index, com 5 análogos parafusados em cada infra-estrutura. Esse conjunto foi posicionado em microscópio para a mensuração dos desajustes antes da aplicação dos revestimentos estéticos, com a finalidade de avaliar apenas desajuste
provocado pela aplicação dos revestimentos estéticos e pelo ciclo de cocção da cerâmica. As infra-estruturas foram separadas, aleatoriamente: G1: resina acrílica ativada termicamente (Clássico, Clássico Artigos Odontológicos Ltda., São Paulo, Brasil); G2: resina fotopolimerizável (Versyo.com, Heraeus Kulzer, Brasil); G3: cerâmica (Triceram, Dentaurum J. P. Winkelstroeter KG ¿ Pforzheim - Alemanha); G4: simulação dos ciclos de cocção da cerâmica. Novamente, após a aplicação dos revestimentos estéticos, foi realizada a avaliação do desajuste marginal sobre o index. Procedeu-se o processo de eletroerosão (Tel Med Technologies, Port Huron, Michigan, EUA). As leituras de desajuste foram realizadas após o aperto com 10 Ncm em um único parafuso, correspondente ao implante A. Através desse procedimento, verificou-se a adaptação dos componentes C e E. O procedimento foi repetido com o outro implante mais distal (E), para mensuração nos implantes A e C. As leituras foram realizadas utilizando microscópio mensurador, com aumento de 120X e precisão de 0,5µm (Micro Vision ¿ Leika, Wetzlar, Alemanha), antes e após aplicação dos revestimentos estéticos, e após o processo de eletroerosão. Os resultados obtidos foram submetidos à Análise de Variância e ao teste de Tukey (p<0,05). Os valores de desajuste marginal das infra-estruturas antes da aplicação dos revestimentos estéticos não apresentaram diferença estatística significante entre si: G1: 29,81 'mu' (+ 10,66); G2: 35,30 'mu' (+ 12,15); G3: 44,75 'mu'(+ 13,73); G4: 38,57 'mu' (+ 16,94). A aplicação dos revestimentos estéticos e a simulação dos ciclos de cocção da cerâmica aumentaram significantemente os valores médios de desajuste marginal para todos os grupos: G1: 221,70 'mu' (+14,11); G2: 81,91 'mu' (+15,71); G3: 233,99 'mu' (+39,18); e G4: 119,75 'mu' (+38,08). Os grupos G1 e G3 não apresentaram diferença estatisticamente significante entre si, mas apresentaram diferença quando comparados aos G2 e G4. Após o processo de eletroerosão, apenas para o grupo G3: 161,16 µm (+36,59 ) a média de desajuste marginal
apresentou-se com valor significamente menor. As médias de desajuste marginal para os grupos G1: 198,68 mu' (+34,19); G2: 62,03 'mu' (+17,73) e G4: 87,98 'mu' (+39,32) foram numericamente menores, porém, sem diferença estatística. Como ocorrido anteriormente, os grupos G1 e G3 não apresentaram diferença estatística significante, mas ambos apresentaram diferença quando comparados aos grupos G2 e G4. A partir dos resultados obtidos no presente estudo, conclui-se que os revestimentos estéticos em resina acrílica ativada termicamente e em cerâmica produziram os maiores valores de desajuste marginal para próteses implanto-retidas, enquanto a resina fotopolimerizável, os menores. A
aplicação de cerâmica nas infra-estruturas produziu maiores valores de desajuste marginal quando comparado à simples simulação dos ciclos de cocção. O processo de eletroerosão mostrou-se eficaz na redução dos desajustes marginais apenas para o grupo com aplicação da cerâmica / Abstract: The demand for a passive fit of frameworks for osseointegrated endousseous implants abutments is well known, because the tightening of an inaccurate framework to the abutments can transmit stress to the bone-metal interface. The purpose of the present study was to evaluate the influence of the veneering application and porcelain firing cycle on the misfit level of implant-supported frameworks. Forty Ti c.p. (Tritan, Dentaurum, Germany) alloy frameworks were fabricated from a metallic index containing 5 Branemark type multi unit abutments. Analogs of the abutments were positioned to the framework, to construct an index for each framework. This index allowed the observation of the marginal gaps caused by the application of the veneering material. The frameworks were grouped
(n=10): 1) heat acrylic resin (Clássico, Clássico, São Paulo, Brazil); 2) light polymerized resin (Versyo.com, Heraeus Kulzer, Brazil); 3) porcelain application (Triceram, Dentaurum - Germany); 4) simulation of porcelain firing cycle. Marginal refinement with spark erosion was conducted on specific equipment (Tel Med Technologies, U.S.A.). The marginal gap
was obtained before and after the veneering materials and the spark erosion procedure, following the single screw test protocol (using a tightening force of 10 Ncm). A traveling microscope (STN ¿ Olympus Optical Co. Ltd Japan (120X) was used, tightening 10N in the titanium screw of the extremity distal implant, measuring the gaps at the central and distal implants. Data were subject Analysis of Variance followed by Tukey test (5%). Marginal gap mean values of the frameworks before the veneering application were not significantly different: G1: 29.81 'mu' (+ 10.66); G2: 35.30 'mu' (+ 12.15); G3: 44.75 'mu' (+13.73); G4: 38.57 'mu' (+ 16.94). The application veneering materials and the simulation of porcelain firing cycle increased significantly the misfit mean values of all groups: G1: 221.70 'mu' (+14.11); G2: 81.91 'mu' (+15.71); G3: 233.99 'mu' (+39.18); e G4: 119.75 'mu' (+38.08). There were no significant differences between G1 and G3, but they were significantly different from both G2 and G3. After the spark erosion process, marginal gap
mean value decreased significantly only G3 group: 161.16 µm (+36.59). G1: 198.68 'mu' (+34.19); G2: 62.03 'mu' (+17.73) and G4: 87.98 'mu' (+39.32) groups decreased the marginal gap mean values, but not significantly after the spark erosion procedure. As occurred after the application of veneering materials, G1 and G3 groups did not show significant difference, but they both were significantly different from G2 and G4 groups. It can be concluded that heat cured acrylic resin and porcelain produced the highest mean values of marginal gaps, while light cured acrylic resin, the lowest. The application of porcelain produced higher misfit values than the simulation of porcelain firing cycles. After the spark erosion process, marginal gap mean value decreased significantly only porcelain application grou / Doutorado / Protese Dental / Mestre em Clínica Odontológica
|
533 |
Desajuste marginal e influencia na pre-carga de parafusos e nas tensões induzidas as fixações de pilares metaloplasticos sobre-fundidos / Marginal misfit and influence in the pre-load and the stress-induced setting of the metaloplastic abutmentsLuthi, Leonardo Flores, 1984- 15 August 2018 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T12:37:57Z (GMT). No. of bitstreams: 1
Luthi_LeonardoFlores_M.pdf: 40460066 bytes, checksum: 7100a1650e58ebfc4a879fff3da50814 (MD5)
Previous issue date: 2010 / Resumo: Pilares tipo UCLA calcináveis são de ampla aplicabilidade na Implantodontia, pois permitem a manipulação em laboratório a custo reduzido e a individualização das próteses em função de cada paciente. Entretanto, apresentam piores resultados de adaptação marginal que os pilares pré-fabricados, embora estes agreguem custos significativamente superiores. Pilares UCLA metaloplásticos para sobre-fundição surgiram neste interstício, com prerrogativas de menores custos que os pré-fabricados e melhor adaptação que os calcináveis. Atualmente encontram-se, predominantemente, com base em liga de Ni-Cr-Ti ou Co-Cr. Todavia, não há dados relativos ao seu desempenho após a sobre-fundição, tão pouco, diante das ofertas, qual seria a melhor escolha. O objetivo neste estudo foi avaliar os desajustes marginais e a influência na indução de tensão e no destorque de parafusos protéticos de próteses confeccionadas com pilares UCLA metaloplásticos confrontando seus resultados com pilares UCLA calcináveis. Foram confeccionadas quarenta infraestruturas metálicas simulando próteses parciais fixas de três elementos retidas por dois implantes osseointegrados, obtidas por fundição a partir de transferências realizadas no modelo mestre. As estruturas foram separadas em quatro grupos (n=10) : G1, cilíndros protéticos tipo UCLA metaloplásticos com base em Co-Cr; G2, cilíndros protéticos tipo do UCLA calcináveis e fundidos em liga de Co-Cr; G3, por cilíndros protéticos tipo UCLA metaloplásticos com base em Ni-Cr-Ti; e G4, por cilíndros protéticos tipo do UCLA calcináveis e fundidos em liga de Ni-Cr-Ti. Para mensuração dos valores de desajuste marginal foi utilizada a técnica do parafuso único, o método de extensometria foi usado para análise das tensões, e os valores de pré-carga dos parafusos, após a ciclagem mecânica, foram obtidos por meio de torquímetro eletrônico digital. Os dados de desajuste marginal e tensão foram verificados antes e após a ciclagem mecânica, já os valores de pré-carga foram obtidos em intervalos de 100 mil ciclos. Os dados foram submetidos à análise variância (Três Fatores), seguidos de teste de Tukey (p=0,05) e a presença de correlação foi verificada por meio do teste de Pearson. Não foi encontrada diferença significativa entre os tipos de pilares para o desajuste, tensão e pré-carga. Os valores médios para desajuste (µm) foram G1 (3608,7 ± 1429,6) G2 (7918,3 ± 5055,9) G3 (4577,3 4017,2) G4 (9824,2 ± 1100,6). Os valores médios para tensão (gf) foram G1 (7918,3 ± 5208,8) G2 (3608,8 ± 2335,9) G3 (9824,3 ± 4125,5) G4 (4577,3 ± 15510,3). Os valores médios de pré-carga (Ncm) dentre os ciclos 0 (11,7 ± 3,8), 100 mil (9,7 ± 3,4), 200 mil (8,9 ± 3,7), 300 mil (9,3 ± 3,2), 400 mil (9,7 ± 3,4), 500 mil (10,6 ± 4). O uso de pilares metáloplasticos não reduziu os valores de desajuste marginal e tensão quando comparados aos calcináveis. A liga de Co-Cr apresentou os menores valores de desajuste marginal. O tipo de pilar e a liga utilizada influenciaram negativamente na perda de pré-carga. Não existe correlação entre tensão, desajuste marginal e pré-carga. / Abstract: Castable UCLA abutments are of wide applicability in dental implants, because they allow the manipulation in the laboratory at low cost and individualization of abutments for each patient. However, they show the worse results of marginal adaptation then the fabricated, although these aggregate costs significantly higher. UCLA premachined abutments for casting came in this interstice, with those of a lower cost than pre-made and better adaptation of the abutment. Nowadays, they are manufactured predominantly based on Ni-Cr-Ti or Co-Cr alloys. However, there is no data on its performance after the overcasting, and little is known about which one would be the best choice. Thus, the aim of this study was to analyze the marginal misfit and its influence on tension induction and in preload values of prosthetic screws in prostheses made with premachined UCLA abutmens. Forty frameworks were prepared simulating three-element metal fixed partial dentures retained by two osseointegrated implants, which were obtained through casting of acrylic resin frameworks waxed in a master model. The structures were distributed into four groups (n = 10): Group 1- premachined Co-Cr UCLA abutment; Group 2- casted Co-Cr UCLA abtument (control group 1); Group 3- premachined Ni-Cr-Ti UCLA abutment and Group 4- casted Ni-Cr-Ti UCLA abutment (control group 2). To measure the values of marginal misfit the single screw technique was used. The method of strain gage was used to analyze the stresses; and the values of preload of the bolts after cycling mechanics, were obtained by means of digital electronic torque meter. The data of marginal misfit and strain were obtained before and after of the mechanical cycling, but the values of pre-load were obtained at intervals of 100 thousand cycles. The data were submitted to variance analysis (Three-Way), followed by Tukey test (p=0.05) and the presence of correlation was verified by means of the Pearson correlation. The average values for marginal misfit (µm) were, G1 (3608.7 ± 1429.6), G2 (7918.3 ± 5055.9), G3( 4577.3 ± 4017.2), G4 (9824,2 ± 1100.6). The average values for tension (gf) were: G1 (7918,3 ± 5208.8), G2 (3608.8 ± 2335.9), G3 (9824.3 ± 4125.5) and G4 (4577.3 ± 15510.3). The averages values of preload (Ncm) among the phases: 0 (11.7 ± 3.8), 100 thousand (9.7 ± 3.4), 200 thousand (8.9 ± 3.7) 300 thousand (9.3 ± 3.2), 400 thousand (9.7 ± 3.4), 500 thousand (10.6 ± 4). The use of premachined UCLA abutment did not reduce the values of marginal misfit and strain when compared with the plastic UCLA abutments. The alloy of Co-Cr showed the lowest values of marginal misfit. The kind of abutmetns and alloy used influenced the values of preload. There was no correlation between strain, marginal misfit and preload. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
534 |
Influencia da termociclagem, escovação mecanica e desinfecção quimica na dureza Knoop e rugosidade de superficie de resinas acrilicas com diferentes ciclos de polimerização / Influence of thermocycling, mechanical brushing and chemical disinfection on the Knoop hardness and surface roughness of acrylic resins with different cycles of polymerizationLira, Andrea Fabiana de 15 August 2018 (has links)
Orientador: Rafael Leonardo Xediek Consani / Tese (doutorado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T21:51:08Z (GMT). No. of bitstreams: 1
Lira_AndreaFabianade_D.pdf: 1753774 bytes, checksum: f60f5f6c197cc4eaf156bebf1bdc75a1 (MD5)
Previous issue date: 2010 / Resumo: Este trabalho avaliou o efeito da termociclagem, escovação mecânica e desinfecção química na dureza e rugosidade de resinas com diferentes ciclos de polimerização. Foram confeccionadas 480 amostras (25 mm x 14 mm x 3 mm) e distribuídas aleatoriamente em 3 grupos de acordo com as resinas: Onda Cryl (G1), QC-20 (G2) e Clássico (G3). Metade das amostras foi submetida a ensaio de rugosidade e a outra metade a ensaio de dureza, antes e após os tratamentos: controle, escovação mecânica ou desinfecção química (hipoclorito e Efferdent) com e sem termociclagem. Amostras G1 foram confeccionadas, polimerizadas em micro-ondas com potência de 900 W; G2 foram polimerizadas a 100°C por 20 minutos e G3 foram polimerizadas a 74°C por 9h. As amostras foram desincluídas e acabadas em politriz com refrigeração à água, em ordem decrescente de granulação. A desinfecção química foi realizada com: 1) Hipoclorito de sódio a 0,5% a 37 ± 1ºC, durante 20 minutos; 2) Peróxido de Hidrogênio, a 37 ± 1ºC, durante 15 minutos. Após as desinfecções, as amostras foram lavadas e imersas em água destilada a 37 ± 1ºC, pelo período restante das 24 h. O processo foi repetido 8 vezes por dia, durante 90 dias (720 ciclos). A escovação mecânica foi conduzida em máquina MSEt à taxa de 5 movimentos por segundo (20.000 ciclos) e as amostras foram avaliadas sem e com envelhecimento térmico com imersões de 60 segundos a 5 ± 1ºC e 55 ± 1ºC, simulando 2 anos. Rugosidade média de superfície foi verificada pela leituras realizadas transversalmente à direção de movimentos lineares de escovação. A dureza Knoop foi verificada, sob carga de 25g/Força de penetração por 5 segundos, em cinco mensurações, antes e após a aplicação dos tratamentos. Foi realizado teste de Kruskal-Wallis e Dunn, Mann-Whitney e Wilcoxon, com 5% de significância. Resultados: Onda-Cryl apresentou dureza (KHN) antes e após os métodos, sem termociclagem, diferença estatisticamente significante (p = 0,013), enquanto entre as resinas com termociclagem, Onda-Cryl (p = 0,001) e QC 20 (p = 0,002) apresentaram diferenças estatisticamente significantes. QC 20 apresentou rugosidade média antes e após os métodos, sem termociclagem, diferença estatisticamente significante (p = 0,003), enquanto entre as resinas com termociclagem, Onda-Cryl (p = 0,046) e QC 20 (p = 0,010) apresentaram diferenças estatisticamente significantes. Entre os métodos sem termociclagem: O peróxido revelou diferença estatisticamente significante na dureza, apenas para Onda-Cryl e na rugosidade, apenas para QC 20 em relação aos métodos peróxido e o hipoclorito. Entre os métodos com termociclagem: Os grupos controle, escovação e peróxido revelaram diferença estatisticamente significante na dureza para Onda-Cryl; o método controle para resina QC 20 e os métodos peróxido e Hipoclorito para Clássico, enquanto a rugosidade revelou diferenças estatisticamente significantes para Onda Cryl em relação ao método peróxido e QC 20 para os métodos peróxido e hipoclorito. Conclusão: houve diferença estatisticamente significante relativa à Dureza apenas para o método controle nas resinas Onda-Cryl e QC 20 independentemente da termociclagem. Não houve diferença estatisticamente significante relativa à rugosidade independentemente da associação entre termociclagem, resinas e métodos / Abstract: This study evaluated the effect of thermocycling, mechanical brushing and chemical disinfection on the hardness and roughness of resins with different polymerization cycles. 480 samples were prepared (25 mm x 14 mm x 3 mm) and distributed randomly into three groups according to the resins: Onda-Cryl (G1), QC-20 (G2) and Classic (G3). Half of the samples were tested as roughness and the other half for testing the hardness, before and after treatments: control, mechanical brushing or chemical disinfection (hypochlorite and Peroxide) with and without thermocycling. G1 samples were fabricated, cured in the microwave with power of 900 W, G2 were polymerized at 100° C for 20 minutes and G3 were polymerized at 74° C for 9h. The samples were deflasked polishing and finished in water-cooled, in decreasing order of grain. The chemical disinfection was carried out with: 1) Sodium hypochlorite 0.5% at 37 ± 1º C for 20 minutes, 2) Hydrogen Peroxide at 37 ± 1º C for 15 minutes. After disinfection, the samples were washed and immersed in distilled water at 37 ± 1º C, for the remainder of 24 h. The process was repeated eight times daily for 90 days (720 cycles). The mechanical brushing was conducted in machine MSET at 5 moves per second (20,000 cycles) and the samples were evaluated with and without thermal aging with dips of 60 seconds to 5 ± 1º C and 55 ± 1º C simulating 2 years. Average surface roughness was determined by readings taken transversely to the direction of linear motion of brushing. Knoop hardness was observed under load 25g/Power penetration for 5 seconds, five measurements before and after treatments. Was performed using the Kruskal-Wallis and Dunn, Mann-Whitney and Wilcoxon, with 5% significance level. Results: Onda-Cryl presented hardness (KHN) before and after methods, without thermocycling, a statistically significant difference (p = 0.013), while among the resins with thermocycling, Onda-Cryl (p = 0.001) and QC 20 (p = 0.002) showed statistically significant differences. QC 20 had average roughness before and after methods, without thermocycling, a statistically significant difference (p = 0.003), while among the resins with thermocycling, Onda-Cryl (p = 0.046) and QC 20 (p = 0.010) were statistically different. Among the methods without thermocycling: The peroxide showed a statistically significant difference in hardness only to Onda-Cryl and roughness, only QC 20 in relation to methods peroxide and hypochlorite. Among the methods thermocycling: Control groups, mechanical brushing and peroxide showed statistically significant difference in hardness for Onda-Cryl; the control method for QC 20 resin and methods for peroxide and hypochlorite Classic, while the roughness, showed statistically significant differences for Onda-Cryl in relation to the peroxide method and 20 for QC methods peroxide and hypochlorite. Conclusion: statistically significant difference on hardness only to the control method in the resins Onda-Cryl and QC 20 regardless of thermocycling. There was no statistically significant difference on the association between roughness regardless of thermocycling, resins and methods / Doutorado / Protese Dental / Doutor em Clínica Odontológica
|
535 |
Efeito da ciclagem térmica e imersão em clorexidina nas propriedades físicas das resinas de bisacrilato de metila e metacrilato de metila / Effect of thermo cycling and chlorexidine immersion in physicals properties of bis-acryl and methacryl resinsFabiano Martins Malafaia 02 June 2009 (has links)
O uso de resinas acrílicas para confecção de restaurações provisórias é bastante difundido na prática odontológica. Dois tipos de resina encontram-se comercialmente disponíveis, as de bisacrilato de metila e as de metacrilato de metila e, em decorrência das exigências funcionais e estéticas das restaurações provisórias, estes materiais devem apresentar resistência, estabilidade de cor e durabilidade. Objetivo: Verificar a resistência à flexão, a microdureza, a rugosidade superficial e a estabilidade de cor de quatro resinas para restaurações temporárias quando submetidas à termociclagem e à imersão em clorexidina. Metodologia: Foram utilizadas as resinas Luxatemp e Structur 2, a base de bisacrilato de metila, e as resinas Duralay e Alike a base de metacrilato de metila. Os corpos-de-prova (n=220) foram divididos em quatro grupos, de acordo com a marca comercial e o ensaio realizado (resistência à flexão, microdureza, rugosidade superficial e estabilidade de cor), sendo avaliados em três tempos distintos: após 24 horas da confecção, após termociclagem (2000 ciclos) e após termociclagem e imersão em clorexidina a 0,12% por 14 dias. Resultados: Os dados obtidos foram analisados com o teste ANOVA e em seguida com o teste t (p<0,05), evidenciando que a termociclagem alterou as propriedades mecânicas das resinas, diminuindo a resistencia a flexão e a microdureza, aumentando a rugosidade superficial e ocasionando alteração de cor. A clorexidina não afetou as propriedades mecânicas das resinas estudadas, porém alterou a cor das resinas de metacrilato. Conclusões: As resinas de bisacrilato apresentaram resultados superiores aos das resinas de metacrilato para todas as variáveis estudadas. A termociclagem afetou negativamente todas as resinas, apenas as resinas de bisacrilato não apresentaram alteração de cor após imersão em clorexidina. / The use of acrylic resins is quite spread in dental practice, being accomplished temporary restorations with this material during the prosthetic treatment. Two chemical groups of this material exist, bis-acryl resins and another of methacrylate resins. Aim: This study verified the flexural resistance, micro hardness, superficial roughness and the color variation of four temporary resins submitted to thermo cycling and chlorexidine immersion. Methods: Luxatemp and Structur 2, bis-acryl based resins, and, Duralay and Alike, methacrylate based resins, has been used. The specimens (n=220) were divided in four groups, in agreement with the accomplished rehearsal, being appraised in three different times: after 24 hours, after the thermo cycling (2000 cycles) and after the thermo cycling followed by the immersion in 0.12% chlorexidine solution during 14 days. The tests were accomplished to the flexural, microhardness, superficial roughness and the color variation verification in all of the experimental times. Results: The results were statistically verified with ANOVA test followed by a t-test (p<0.05). Thermo cycling decreased flexural resistance and micro hardness, increased superficial roughness and caused color variation in all studied resins. Chlorexidine immersion did not changes physicals properties of studied resins, but caused color variation in methacrylate resins. Conclusions: The bis-acryl resins obtained results superiors to the checked for the methacrylate resins in all the experimental tests. Thermo cycling manegeament affected negatively all the studied resins. Only bis-acryl resins didnt presented color variation caused by chlorexidine immersion.
|
536 |
Propriedades mecânicas de cerâmicas de zircônia tetragonal policristalina contendo ítrio (Y-TZP) após aplicação de cerâmica / Mechanical properties of different stabilized tetragonal zirconia polycrystalline (Y-TZP) ceramics after veneering with ceramicMarcelo Garbossa Francisco 16 April 2010 (has links)
Objetivo: Quantificar e comparar propriedades mecânicas, tais como resistência ao cisalhamento da interface de aderência zircônia/cerâmica, microdureza e resistência à flexão de corpos-de-prova confeccionados com diferentes cerâmicas de zircônia tetragonal policristalina contendo ítrio (Y-TZP) e cerâmica de revestimento aplicada. Método: Foram comparados, por meio de ensaios mecânicos, corpos-de-prova contendo zircônia nanopartículada ProtMat (Guaratinguetá, Brasil) e corpos-de-prova contendo zircônia microparticuladas ProtMat (Guaratinguetá, Brasil), Vita 2000 YZ CUBES (Zahnfabrik, Bad Säckingen Alemanha) e IPS e.maxZircad Ivoclar (Schaan/Liechtenstein). Foram confeccionados 84 corpos-de-prova (CP) em forma de blocos ou barras, estas últimas para o ensaio de flexão, sendo 21 de cada marca de zircônia. Todos os CPs foram sinterizados e uma zircônia de cada grupo foi caracterizada por difração de raios-X. Posteriormente foi realizada a aplicação de cerâmica CZR-Cerabien Zr (Noritake shinmachi, Nishi-ku, Nagoya, Japão) sobre os outros oitenta CPs, dos quais cinco CPs de cada grupo receberam a cerâmica em forma quadrangular e nos outros cinco CPs e em todas as barras foi aplicada à cerâmica de revestimento em toda a face. Foi realizado o ensaio de cisalhamento na interface de aderência zircônia/cerâmica dos CPs a partir de uma máquina de ensaio universal e avaliada a microdureza Vickers da interface dos CPs e o ensaio de flexão em quatro pontos das barras. Os CPs foram ainda avaliados sob microscópio óptico para verificação da interface zircônia/cerâmica e análise do tipo de fratura apresentada. Resultados: Os valores de dureza Vickers, tenacidade à fratura, resistência à flexão e resistência ao cisalhamento apresentados pelos corpos-de-prova preparados com partículas micrométricas foram de 1300HV, 9MPam-, 850MPa e 60kgf, respectivamente. Só houve diferença estatística nos ensaios de flexão e tenacidade à fratura, tendo a ProtMat nanoparticulada apresentado valores superiores quando comparada às demais. Conclusões: Os CPs apresentaram dureza, tenacidade à fratura, resistência à flexão e ao cisalhamento adequados para a utilização em odontologia, tendo os mesmos apresentado comportamentos semelhantes, apesar da resistência dos CPs em zircônia nanoparticulada ter sido superior à resistência da zircônia microparticulada. / Aim: The aim of this study was to quantify and compare mechanical and physical properties, such as Vickers hardness, fracture toughness, flexural strength and shear resistance of blanks of different Y-TZP zirconia ceramics used in the manufacture of dental prostheses after veneering with Noritake. Method: Commercially nano and microcrystalline zirconia blocks, pre-sintered bars and stabilized with yttria produced in Brazil (ProtMat) and imported (VITA 2000 YZ CUBES and IPS e.maxZircad Ivoclar). Eighty-four commercially samples were sintered from 1350C to 1530C as recommended procedure by the manufactures. The results of X-ray diffraction showed that the blocks presented just the tetragonal phase. The blocks were veneered with CZR-Cerabien Zr ceramic (Noritake shinmachi, Nishi-ku, Nagoya, Japão) and afterwards submitted to mechanical tests. Vickers indentation tests were performed to determine hardness and toughness. The shear loading test was performed by using an universal machine and then evaluate the Vickers hardness of the blocks. The flexural resistance was done in four different points in the bars. The samples were observed by SEM to analyze fractures characteristics. Results: Zirconium showed similar physical and mechanical properties with no statistically significant differences on the hardness and resistance to fracture. Nanocrystalline zirconium showed higher toughness and flexural resistance results when compared with microcrystalline ones. Conclusions: Although the samples of nanocrystaline zirconium showed high values, the materials showed similar Vickers hardness, fracture toughness, flexural strength and shear resistance and all of them can be indicated to be used in dentistry.
|
537 |
Neoplasias malignas em cavidade orbitária e reabilitação pós-cirúrgica em um hospital brasileiro de oncologia - estudo retrospectivo de 12 anos / Malignant neoplasms in the orbit and post-surgical rehabilitation in a Brazilian hospital oncology - a retrospective study of 12 yearsSIRIANNI, Daniela 06 August 2010 (has links)
Made available in DSpace on 2014-07-29T15:21:56Z (GMT). No. of bitstreams: 1
Dissertacao daniela sirianni.pdf: 497398 bytes, checksum: fd20139664c8c71e41d1aa9caae182c6 (MD5)
Previous issue date: 2010-08-06 / Malignant tumors in the orbital cavity often require surgical treatment, however, few studies recording the prevalence of tumors in the orbit and post-surgical rehabilitation through maxillofacial prosthetics. The aim of this study was to investigate the prevalence of malignant tumors in the orbital cavity, employed as the surgical treatment and prosthetic rehabilitation after surgery. A retrospective convenience sample was selected from 269 charts of patients treated at Hospital Araújo Jorge (Goiânia, Goiás, Brazil), regional referral center for cancer treatment and supported by the National Health System, from 1998 to 2009. Data concerning the clinical and pathological, psychological support, rehabilitation, prosthetics and clinical outcome were investigated. Descriptive statistical analysis revealed that the age group ranged from 1 to 92 years, mean 43.5 years, 50.2% of female patients. Tumors were more prevalent basal cell carcinoma (58%), retinoblastoma (17.1%), squamous cell carcinoma of the conjunctiva (7.1%), malignant melanoma (6.7%) and rhabdomyosarcoma (4.5%). Of the total, 250 patients (92.3%) underwent surgery by exenteration (78%) or enucleation (21.6%). Variables associated with the rehabilitation aesthetic eye were age (p <0.001) and type of surgery (p <0.001). It follows then that there are low rates of prosthetic care and psychological care offered to patients and that the process was influenced by the esthetic rehabilitative patient's young age and in cases of surgical enucleation of the eyeball / Tumores malignos em cavidade ocular em geral requerem tratamento cirúrgico, porém, há poucos estudos registrando a prevalência de tumores na região orbital e a reabilitação pós-cirúrgica através de próteses bucomaxilofaciais. O objetivo deste estudo foi investigar a prevalência de tumores malignos na cavidade orbitária, as modalidades cirúrgicas empregadas como tratamento e a reabilitação protética pós-cirúrgica. Uma amostra retrospectiva de conveniência foi selecionada de 269 prontuários de pacientes atendidos no Hospital Araújo Jorge (Goiânia, Goiás, Brasil), referência regional para tratamento oncológico e apoiado pelo Sistema Único de Saúde, no período entre 1998 a 2009. Dados relativos a variáveis clínico-patológicas, suporte psicológico, reabilitação protética e desfecho clínico foram investigados. A análise estatística descritiva revelou que a faixa etária variou de 1 a 92 anos, com média de 43,5 anos, sendo 50,2% dos pacientes do gênero feminino. Os tumores mais prevalentes foram carcinoma basocelular (58%), retinoblastoma (17,1%), carcinoma espinocelular de conjuntiva (7,1%), melanoma maligno (6,7%) e rabdomiossarcoma (4,5%). Do total, 250 pacientes (92,3%) foram submetidos a cirurgia por meio de exenteração (78%) ou enucleação (21,6%). As variáveis associadas a reabilitação estética ocular foram idade (p<0,001) e tipo de cirurgia (p<0,001). Conclui-se, então, que há baixos índices de cuidados protéticos e atenção psicológica oferecida aos pacientes e, que o processo estético reabilitador foi influenciado pela idade jovem do paciente e nos casos de enucleação cirúrgica do globo ocular.
|
538 |
Análise da distribuição de tensões do conjunto implante/prótese de implantes de zircônia na região periimplantar / Analysis of the distribution of deformations on the implant/prosthesis assembly of zirconium implants in the peri-implant regionMelody Analia Chase Diaz 26 February 2015 (has links)
Este estudo teve como objetivo analisar as tensões do osso periimplantar, analisando as forças axiais e oblíquas incidentes em um modelo 3D usando Método de Elementos Finitos (MEF) a partir de modelo experimental in vitro, que consistiu em: 1 implante Brånemark System MkIIIGroovde (3,75 mm de diâmetro, 13,0 mm de comprimento); 1 pilar multi-unit de 5mm de altura com parafuso de titânio e torque de 20Ncm; infraestrutura de cobalto-cromo revestida com cerâmica feldspática aparafusada com torque de 10 Ncm, e poliuretano simulando o osso. Para obter dados de deformação, extensômetros lineares elétricos (Strain Gauges) foram utilizados e os valores obtidos foram comparados com o MEF gerado a partir do escaneamento do modelo em Micro CT e reconstruído tridimensionalmente no software Simpleware. Uma vez construído o modelo do MEF, as propriedades mecânicas dos implantes de titânio foram substituídas pelas propriedades dos implantes de zircônia Y-TZP no programa ANSYS. Uma carga vertical e uma oblíqua, cada uma de 300N, foram aplicadas no centro da face oclusal da coroa de cada modelo e, em seguida, as tensões foram verificadas na região do osso periimplantar. As tensões encontradas no modelo de EF com força vertical aplicada foram 0,92 MPa na região vestibular, 1,15 MPa na lingual, 0,98 MPa na mesial e 1,00 MPa na região distal para implante de titânio. Quando utilizado implante de zircônia com carga aplicada vertical os valores de tensão foram em vestibular 11,66 MPa, em lingual 9,73 MPa, em mesial 9,76 MPa e em distal 9,59 MPa. No modelo de EF com força oblíqua de 30o os valores foram em vestibular 0,92 MPa, em lingual 1,14 MPa, em mesial 0,97 MPa e em distal 0,99 MPa com o mesmo implante de titânio. O mesmo implante com carga inclinada (30o) gerou valores de tensão de 10,23 MPa em vestibular, 8,30 MPa em lingual, 8,48 MPa em mesial e 9,51 MPa em distal. A tensão diminuiu numericamente com o implante de zircônia, com as incidências de cargas verticais e oblíquas. / This study aimed to analyze the tensions of the periimplant bone around a single implant, analyzing axial and oblique incident forces in a 3D Model using Finite Element Method. Experimental in vitro model consisted of: Brånemark System MkIIIGroovde implant (3.75 mm diameter, 13.0 mm length); multi-unit set abutment of 5mm height with titanium screw and trque of 20Nm; cobalt-chromium coping coated with feldspathic ceramic screwed with a torque of 10Nm, and olyurethane simulating the bone. Strain gauges were used to set up this experimental model and the values obtained were compared with FEM generated from the model scanning in Micro CT and developed in Simpleware software. After this, the mechanical properties of the titanium implants were replaced by the properties of Y-TZP zirconium implants in ANSYS software. A vertical and an oblique load, each one of 300N, were applied on the center of the occlusal aspect of the crown of each model and then the tensions were verified in the periimplant bone region. The tensions generated in the FE model with vertical force applied were 0.92 MPa on vestibular region, 1.15 MPa on lingual, on mesial 0.98 MPa and 1.00 MPa on distal region for titanium implant. When applied vertical load in zirconia implant, the values were 11.66 MPa on vestibular, 9.73 MPa on lingual, 9.76 MPa on mesial and 9.59 MPa on distal. In the FE model under 30o oblique load, the values were 0.92 MPa on vestibular, 1.1457 MPa on lingual, 0.97 MPa on mesial and 0.99 MPa on distal with the same titanium implant. Zirconium implant with oblique load (30o) generated tension values of 10.23 MPa on vestibular, 8.30 MPa on lingual, 8.48 MPa on mesial and 9.51 MPa on distal. The stress numerically decreased with zirconia implant with vertical and oblique loads.
|
539 |
Dimensões dos dentes anteriores superiores naturais comparadas com dentes anteriores superiores artificiais / Dimensions of natural maxillary anterior teeth compared with artificial maxillary anterior teethNeves, Ricardo Guimarães 20 March 2015 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2017-04-17T17:32:47Z
No. of bitstreams: 2
Dissertação - Ricardo Guimarães Neves - 2015.pdf: 8553220 bytes, checksum: 28f892ff25d443158e4285be19a1a15e (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-04-18T15:48:58Z (GMT) No. of bitstreams: 2
Dissertação - Ricardo Guimarães Neves - 2015.pdf: 8553220 bytes, checksum: 28f892ff25d443158e4285be19a1a15e (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-04-18T15:48:58Z (GMT). No. of bitstreams: 2
Dissertação - Ricardo Guimarães Neves - 2015.pdf: 8553220 bytes, checksum: 28f892ff25d443158e4285be19a1a15e (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2015-03-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The objective of this study was to evaluate comparatively dimensions of natural upper anterior teeth with artificial teeth of three trademarks Premium PalaTM (Heraeus Kulzer), SR Vivodent PETM (Ivoclar Vivadent), TriluxTM (VIPI), in order to identify models of artificial teeth that best reproduce the dimensions present in the natural human dentition in both genders. For measurements of natural teeth were used 96 dental casts arising from people of both genders, in which molding of the upper arch was performed to obtain study models for the purpose of performing dental measure using a digital caliper: width (LIC) and length (CIC) of the upper central incisor teeth obtained by averaging 11 and 21; and width of maxillary anterior teeth straight (LR) obtained by the sum of the individual widths of the upper anterior teeth. Additionally the width was measured from the upper anterior teeth in curve (LC), obtained with flexible ruler positioned on the buccal region of greatest volume between the distal surfaces of the upper canines and sustained in the buccal region of greatest volume of teeth. Corresponding measures of artificial teeth were obtained based on the values described in the template letter provided by the manufacturers. Comparisons between genders were carried out by the t test (α = 0.05) and absolute frequencies were used to tabulate and compare measures of natural and artificial teeth. Out of the 96 volunteers, 41 were male and 55 were female, with an average age between 22.5 and 21.8 years, respectively, without statistically significant differences (p> 0.05). All measurements were performed statistically different between genders (p <0.05), with higher values for male. Most models of artificial and natural teeth presented LIC in the range between 8.0 to 8.5 mm. As for CIC, most volunteers is between 10.6 to 11.0 mm, while most models of artificial teeth is between 9.6 to 10.0 mm. Most models of artificial teeth and volunteers have LR between 46-47 mm. Only the letter template of teeth TriluxTM provides the LC measure, with most models between 50-51 mm. Yet most volunteers are between 54-55 mm. It can be concluded that the trademarks of artificial teeth evaluated feature models with width measurements compatible with natural teeth; however, the length of the upper central incisor is about 0.5 to 1.5 mm smaller than that observed in the majority of volunteers. There are models of artificial teeth that present CIC and LC with non-existent measures in the population studied. / O objetivo deste trabalho foi avaliar comparativamente dimensões de dentes anteriores superiores naturais com dentes artificiais de três marcas comerciais Premium Pala® (Heraeus Kulzer), SR Vivodent PE® (Ivoclar Vivadent), Trilux® (VIPI), a fim de identificar modelos de dentes artificiais que melhor reproduzem as dimensões presentes na dentição humana natural em ambos os gêneros. Para mensurações dos dentes naturais foram utilizados 96 modelos de gesso oriundos de pessoas de ambos os gêneros, nos quais foram realizadas medidas utilizando um paquímetro digital: largura (LIC) e comprimento (CIC) do incisivo central superior, obtidos pela média dos dentes 11 e 21; e largura dos dentes anteriores superiores em linha reta (LR), obtida pela soma das larguras individuais dos dentes anteriores superiores. Adicionalmente foi aferida a largura dos dentes anteriores superiores em curva (LC), obtida com régua flexível posicionada entre as superfícies distais dos caninos superiores e apoiada na região vestibular de maior volume dos dentes. Medidas correspondentes dos dentes artificiais de três marcas comerciais foram obtidas com base nos valores descritos na carta molde fornecida pelos fabricantes. Comparações entre gêneros foram realizadas pelo teste t (α=0,05) e frequências absolutas foram usadas para tabular e comparar medidas dos dentes naturais e artificiais. Dos 96 modelos, 41 eram oriundos do gênero masculino e 55 do gênero feminino, de participantes com idade média de 22,5 e 21,8 anos, respectivamente, sem diferenças estatísticas significantes (p>0,05). Todas as mensurações realizadas foram estatisticamente diferentes entre os gêneros (p<0,05), com valores maiores para o masculino. A maioria dos modelos de dentes artificiais e naturais apresentaram LIC no intervalo entre 8,0 - 8,5 mm. Já para CIC, a maioria dos dentes naturais está entre 10,6 - 11,0 mm, enquanto a maioria dos dentes artificiais está entre 9,6 - 10,0 mm. A maioria dos modelos de dentes artificiais e naturais possuem LR entre 46 - 47 mm. Apenas a carta molde dos dentes Trilux® disponibiliza a medida LC, com a maioria dos modelos entre 50 - 51 mm. Já a maioria dos dentes naturais está entre 54 - 55 mm. Pode-se concluir que as marcas comerciais de dentes artificiais avaliadas apresentam modelos com medidas de largura compatíveis com dentes naturais, porém o comprimento do incisivo central superior tende a ser de 0,5 a 1,5 mm menor do que o verificado na dentição natural. Existem modelos de dentes artificias que apresentam CIC e LC com medidas inexistentes na população estudada.
|
540 |
Níveis de óxido nítrico salivar e indicadores clínicos e bioquímicos de aterosclerose entre usuários de próteses dentárias removíveis / Levels salivary nitric oxide and clinical and biochemical indicators of atherosclerosis between users of removable dental prosthesesDayana Freitas 21 September 2016 (has links)
A literatura aborda vastamente a relação entre as inflamações e infecções bucais e a ocorrência de doenças cardiovasculares, entre elas a aterosclerose. Sabemos que o uso de próteses dentárias totais removíveis pode causar inflamação bucal, porém a relação entre inflamações/infecções relacionadas ao uso de próteses e a ocorrência de doenças cardiovasculares ainda não foi suficientemente descrita. O objetivo do presente estudo foi investigar a correlação entre indicadores clínicos e bioquímicos de aterosclerose e os índices de nitrato salivar de usuários de próteses dentárias totais removíveis. Trata-se de um estudo de abordagem quantitativa, correlacional, descritivo, de corte transversal, realizado em uma Unidade de Saúde Preventiva em um município do interior paulista, no período de julho de 2014 a março de 2015. A amostra foi constituída por 44 indivíduos edêntulos totais e usuários de próteses dentárias totais removíveis. Foram avaliadas as variáveis sociodemográficas (sexo, idade, cor da pele, situação familiar conjugal, escolaridade, profissão/ocupação); as características clínicas (medida indireta da Pressão Arterial e Índice Tornozelo Braquial); as variáveis bioquímicas (Colesterol Total e glicemia capilar) e os níveis de óxido nítrico (NO) salivar, obtidos pela dosagem de nitrato realizada por técnica de quimioluminescência. As análises descritivas, com cálculo de frequências absolutas e porcentagens e descrição das médias, desvio padrão e medianas, foram realizadas por meio do pacote estatístico Statistical Package for Social Science - SPSS, versão 16.0. Para análise de correlação linear entre as variáveis foi utilizado o coeficiente de correlação de Spearman. Os resultados foram expressos como valores máximos e mínimos, medianas, médias ± erros padrões das médias (EPM), e as diferenças consideradas estatisticamente significativas para p<0,05. O projeto foi aprovado pelo Comitê de Ética em Pesquisa da Escola de Enfermagem de Ribeirão Preto-USP. A análise do perfil sociodemográfico indicou que a amostra foi composta essencialmente por mulheres, com idade média de 62,9±7,9 anos, cor da pele branca, que conviviam com companheiros e filhos, apresentaram baixos índices de escolaridade e exerciam atividades no próprio lar. A maioria dos participantes (54,4%) informou ter diagnóstico prévio de Hipertensão Arterial Sistêmica e 38,7% apresentaram níveis alterados de pressão arterial no momento da medida. Mais da metade da amostra foi classificada com tolerância diminuída à glicose (56,8%); 22,7% apresentaram níveis elevados de CT e 22,7% apresentaram índices de ITB>1,3, valor indicativo de calcificação arterial. Os participantes apresentaram elevados índices de nitrato salivar, com média de 462,2µM/ml. Não observamos correlação entre as variáveis descritas e os níveis de nitrato salivar. Nossos resultados indicam que a população estudada apresenta fatores de risco para doenças cardiovasculares e aterosclerose. A ausência de correlação entre as variáveis clínicas e bioquímicas e os níveis de NO salivar indicam que, no presente estudo, o NO não se mostrou um bom marcador de alterações sistêmicas. Podemos considerar que os elevados índices de NO salivar indicam possibilidade de inflamações/infecções focais entre usuários de próteses dentárias, contudo são necessários estudos adicionais para averiguar se estas alterações bucais podem levar ao aumento do risco cardiovascular / The literature widely covers the relations between the inflammations and mouth infections and the occurrence of cardiovascular disease, including atherosclerosis. It is known that the use of dental prosthesis, removable or not can cause mouth inflammations, but the linking between the infection related to the use of prostheses and cardiovascular diseases has not been described enough. The purpose of this study was to investigate the correlation of clinical and biochemical indicators of atherosclerosis and salivary nitrates rates of complete denture wearers. It is a quantitative, descriptive and correlational study of a cross section carried out in a Preventive Health Office in a small city in the state of Sao Paulo, from July 2014 to March 2015. In the sample there were 44 edentulous users of removable dental prosthesis. The evaluation included socio-demographic variations (sex, age, skin color, marital status, education degree, profession); clinical characteristics (indirect measure of blood pressure and ankle brachial index) ; biochemical variations (total cholesterol and capillary glycemia) and the levels of salivary nitric oxide (ON), obtained by the nitrate dosing carried out through chemiluminescence technique. The descriptive analysis with calculation of absolute frequencies, percentage and description of standard deviation averages were accomplished through Statistical Package for Social Science_ SPSS, version 16.0. The coefficient of Spearman correlation has been used to analyze the linear correlation among the variations. The results were expressed as maximum and minimum values and difference significant to p 0,05. The Project was approved by the Comite de Etica em Pesquisa da Escola de Enfermagem de Ribeirao Preto - USP. The sócio-demographic analysis has indicated that the sample was compound mostly by women aged from 62,9 about 7,9, White skin,, living with husband and children, who had low education degree and were housewives. Most of the sample (54,4%) iwere previously diagnosed with Systemic Arterial Hypertension and 38,7% showed altered levels of blood pressure at the moment of de measurement. More than 50% of the sample was classified with glucose tolerance diminished (56,8%); 22,7% presented enhanced levels of CT and 22,7% presented index of ITB 1,3, indicative of arterial calcification. The subjects presented high levels of salivary nitrate, average 462,2uM/ml. Correlation between the described variations and the levels of salivary nitrate has not been observed. Our results indicate that the subjects show risk factors to develop atherosclerosis and cardiovascular diseases. The absence of correlation among the clinical and biochemical variations, and the levels of salivary ON indicate that, in this study, the ON has not been a good indicator of systemic alterations. It can be considered that enhanced levels of salivary ON indicate a possibility of focal inflammations among wearers of dental prostheses, although further studies are necessary to check if these oral alterations can increase the cardiovascular risk
|
Page generated in 0.05 seconds