• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 60
  • 14
  • 2
  • Tagged with
  • 77
  • 17
  • 11
  • 11
  • 11
  • 11
  • 10
  • 9
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Vaisseau sanguin reconstruit par génie tissulaire : développement d'une nouvelle approche pour la reconstruction de la media et interaction avec les microparticules

Bourget, Jean-Michel 24 April 2018 (has links)
Tableau d'honneur de la Faculté des études supérieures et postdorales, 2014-2015 / La media vasculaire est au coeur des processus physiopathologiques qui entraînent le développement de l’athérosclérose. L’utilisation d’une media reconstruite par génie tissulaire permet d’étudier les cellules musculaires lisses (CML) humaines dans un environnement plus physiologique que les cellules en culture monocouche. Les travaux présentés dans cette thèse sont orientés autour de la media vasculaire reconstruite par génie tissulaire comme modèle d’étude pharmacologique et prothèse vasculaire autologue. La première partie des travaux porte sur l’étude des interactions de cette tunique avec les microparticules (MP) circulantes. D’abord, nous avons montré que la présence de l’adventice modifie la réponse de la media aux MP produites in vitro à partir des lymphocytes T. Ensuite, l’étude de l’effet des MP isolées du sérum de patients en choc septique sur la media humaine a démontré que ces MP sont en mesure d’augmenter la contraction de la media par un mécanisme impliquant une diminution du NO et une augmentation de l’expression de l’ARN messager de l’interleukine-10. L’incubation de la media reconstruite avec cette cytokine anti-inflammatoire bloque l’hyporéactivité induite par les lipopolysaccharides. Le même phénomène a été reproduit in vivo, chez le rongeur. Ces résultats suggèrent que les SMP auraient un effet protecteur sur la fonction vasculaire, en potentialisant la contraction de la media. Ensuite, nous avons optimisé l’approche de reconstruction de prothèses vasculaires par auto-assemblage proposée initialement pour l’adapter au contexte particulier des CML. L’objectif principal était de permettre l’étude physiopathologique de la media à partir de toutes les lignées de CML; indépendamment de leur capacité de synthèse de matrice extracellulaire. Pour ce faire, nous avons développé un échafaudage de matrice extracellulaire produit par auto-assemblage à partir de fibroblastes humains. L’utilisation de cet échafaudage génère une media plus résistante et plus contractile que la technique initiale. Enfin, une anisotropie a été créée dans cet échafaudage pour permettre une orientation physiologique des CML. La media reconstruite devient ainsi plus résistante et plus contractile. Ces améliorations permettent de reconstruire des media à partir des cellules de plus de patients et mèneront à des études pharmacologiques plus représentatives de la population. Cet échafaudage facilitera la translation clinique de ce modèle de media reconstruite par génie tissulaire. / The pathological processes that result in the development of atherosclerostic lesions take place in the vascular media layer. This condition is responsible for half of cardiovascular associated fatalities. The development of a tissue-engineered blood vessel can contribute to the in vitro study of the human media in a 3-dimensional environment. This blood vessel can also be used as a prosthesis for arterial bypasses. The work presented here focus on the reconstructed vascular media as a pharmacological model and a potential vascular substitute. The vascular media reconstructed by self-assembly was used to study the interactions between this layer and circulating microparticles (MPs). We demonstrated that the adventitia layer can influence the response of the media to T-Lymphocytes derived MPs. Next, we investigated the influence of MPs isolated from whole blood of septic shock patients (SMPs), on the human engineered media. This study demonstrated that the SMPs decrease nitric oxide (NO) production and increase interleukin-10 (IL-10) messenger RNA in the media layer. Incubation of reconstructed media with this anti-inflammatory cytokine blocks the hyporeactivity induced by lipopolysaccharides. This finding was confirmed in vivo, in rodents. Therefore, the elevation of MP levels in sepsis is potentially probeneficial to the cardiovascular function in this pathology. We then investigated the feasibility of improving the reconstructed media in order to facilitate the physiopathological studies of this layer and improve the potential of a smooth muscle cell (SMC)-containing substitutes to be implanted in human. Therefore, the self-assembly approach was used to generate an extracellular matrix (ECM) scaffold, produced in vitro by fibroblasts, in which SMCs can be seeded. After a week of culture in a decellularised matrix scaffold, the SMC-containing sheets were rolled around a mandrel to form a media layer. This engineered media demonstrated an increase mechanical resistance and contractility as compared with the original technique. Finally, we created an anisotropic ECM scaffold that can direct the orientation of SMCs to reproduce the physiological orientation of that layer. Reconstructed media produced using those anisotropic scaffolds were more resistant and contractile than the ones reconstructed using isotropic scaffolds. These improvements will facilitate the reconstruction of a media layer using pathological cells from patients and could lead to more representative pharmacological study of this layer. Moreover, this scaffold will facilitate the clinical translation of the model from bench to bedside.
52

Evaluation dosimétrique dfes algorithmes implémentés dans les systèmes de planification de traitement en présence d'hétérogénéités de forte densité : cas de la sphère ORL en radiothérapie externe / Dosimetric evaluation of agorithms in treatment planning system with hight density inhomogeneity : case of head and neck cancer in radiation therapy

De conto, Celine 21 November 2014 (has links)
Ces dernières années, les techniques de traitement des cancers par radiothérapie externe se sont complexifiéesafin de cibler la tumeur tout en protégeant les organes à risque. Les systèmes de planification de traitement (TPS)réalisent un calcul prévisionnel de la distribution de la dose absorbée dans le patient (via des images CT).Afin d’obtenir un résultat de dose précis dans un temps raisonnable, le calcul est effectué par des algorithmessimplifiés. En présence de dispositifs médicaux métalliques de masses volumiques élevées (prothèses de hancheou prothèses dentaires), les algorithmes atteignent leurs limites. De plus, ces dispositifs perturbent lareconstruction tomodensitométrique en créant des artéfacts sur les images rendant difficile la délinéation desorganes. L’objectif de ce travail a été d’évaluer les algorithmes implémentés dans les TPS en présenced’hétérogénéités de forte densité avec des mesures expérimentales et le code de calcul Monte-Carlo BEAMnrcdans un fantôme anthropomorphique tout d’abord avec des échantillons naturels, puis avec des échantillonscalibrés. Ensuite, une évaluation rétrospective des algorithmes cliniques par rapport à Monte-Carlo a été réaliséeavec des patients traités en RC3D et en RCMI.Les mesures ont mis en évidence une atténuation pouvant aller jusqu’à 17 % pour l’amalgame dentaire parrapport à l’algorithme clinique sur les images CT avec artéfacts, créant une zone de sous-dosage dans le volumecible. L’ensemble des résultats a donné lieu à des recommandations pour la clinique (corriger les images CT si levolume cible est à moins de 3 cm d’une prothèse, privilégier l’algorithme AAA plutôt que Pencil Beam…). / The last few years, cancer treatment techniques in radiation therapy have become more complex to better targetthe tumor while protecting the organs at risk. The treatment planning systems (TPS) achieve a predictivecalculation of the distribution of the dose absorbed by the patient (via CT images).In order to obtain an accurate dose result within a reasonable time, the calculation is performed with simplifiedalgorithms. In the presence of medical devices made of high density metal (hip prosthesis or dental prosthesis),the algorithms reach their limits. Moreover, these devices disrupt computed tomography reconstruction, creatingartifacts on the images and thus making difficult the delineation of organs. The aim of this work is to evaluatethe algorithms of the TPS in the presence of high density heterogeneity using experimental measurements andthe Monte Carlo BEAMnrc code in an anthropomorphic phantom: on one hand with natural samples, and on theother hand, with calibrated samples. Then, a retrospective evaluation of clinical algorithms compared to MonteCarlo is achieved using treated patients in Conformal Radiotherapy and in Intensity Modulated RadiationTherapy (IMRT). The measurements show an attenuation of up to 17 % for dental amalgam compared with theclinical algorithm on CT images with artifacts, creating an under-dosage area in the target volume. All theseresults lead to recommendations for the clinical treatments (corrected CT images if the target volume is closerthan 3 cm to prosthesis, favor the AAA algorithm rather than Pencil Beam …).
53

Contribution à l'étude de la compliance et du vieillissement des prothèses artérielles / Contribution to the study of the compliance and the ageing of arterial prostheses

Khoffi, Foued 20 December 2012 (has links)
Cette étude a pour but d’étudier la compliance et le vieillissement des prothèses artérielles dans des conditions in-vitro réalistes. Une technique de mesure de la compliance statique et dynamique des prothèses artérielles sans ajout de membrane étanche, a été mise au point, contrairement aux essais pratiqués par tous les dispositifs actuels. Les résultats obtenus montrent que les prothèses sont bien moins compliantes qu’annoncé par les fabricants et présentent une compliance très éloignée des artères saines de l’hôte. Il a été démontré que l’ajout d’une membrane même très souple, introduit des couplages entre la structure prothétique et la membrane. La caractérisation physico-chimique des prothèses ayant subi le vieillissement accéléré a permis d’en comprendre les mécanismes liés à la détérioration de la « durée de vie utile » de ces prothèses. Ce processus est marqué essentiellement par une modification de la structure textile de la prothèse (surtout une forte atténuation de cosselage) et une chute de la compliance longitudinale et de la compliance radiale. De plus, une diminution légère des propriétés dynamométriques des filaments constituant les prothèses a été mise en évidence. La dégradation s’est aussi manifestée par une variation du taux de cristallinité des fibres. / The goal of this work is to study the compliance and the ageing of arterial prostheses under in vitro realistic conditions. A technique for measuring the static and dynamic compliance of arterial grafts without internal compliant membrane (ICM) was developed, contrary to the tests performed by all the current devices. Results have show that the prostheses are less compliant than announced by the manufacturers and have a very remote compliance than the healthy host arteries. It was demonstrated that the addition of an ICM introduces coupling between the prosthetic structure and the balloon. The physico-chemical characterization of the prostheses having undergone the accelerated ageing allowed to understand the mechanisms related to the deterioration of the "useful life" of these prostheses. This process is essentially marked by a modification of the textile structure of the prosthesis (particularly a high attenuation of crimping) and a fall of the longitudinal compliance and the radial compliance. In addition, a slight decrease of tensile properties of the filaments constituting the prosthesis was highlighted. Degradation is also appeared by a change in the rate of crystallinity of fibers.
54

Étude biomécanique du coupe de frottement céramique-céramique dans les prothèses totales de hanche sans ciment / Biomechanical strudy of ceramic on ceramic cementless total hip arthroplasty

Chevillotte, Christophe 20 September 2012 (has links)
Le but du travail réalisé dans cette thèse était d’approfondir les connaissances en matière d’utilisation du couple de frottement céramique-céramique dans l’implantologie moderne de hanche sans ciment. L’étude clinique de 100 prothèses totales de hanche sans ciment avec un recul de 9 ans a permis de montrer la fiabilité du couple de frottement céramique en terme d’usure, de biocompatibilité et d’ostéointégration. Par la suite, la comparaison de la méthode d’implantation de ces implants (impaction du métal-back avec ou sans adjonction de vis supplémentaires) a montré que la rigidité de la céramique n’était pas incompatible avec une impaction simple du métal-back, pour des patients qui ne présentent pas de fragilité osseuse. Nous avons ensuite étudié plus particulièrement une complication de la céramique, le grincement ou squeaking. Une étude in vitro du phénomène, a permis de reproduire ce phénomène dans des conditions de lubrification optimale, avec la présence d’un troisième corps métallique entre les surfaces de frottement, suggérant l’importance des problèmes de lubrification dans la genèse du phénomène. L’analyse d’explant a conforté notre hypothèse, mettant en évidence l’importance du dessin des implants afin d’éviter les conflits prothétiques pouvant générer des particules métalliques. Enfin, l’analyse sur le long terme du phénomène de squeaking a montré son faible impact sur la survie des implants et sur la qualité de vie des patients. Ce travail, qui a associé des analyses cliniques et biomécaniques nous conforte dans l’utilisation de la céramique comme couple de frottement dans les prothèses totales de hanche sans ciment, insiste sur l’importance du dessin et du positionnement des implants pour éviter les complications qui peuvent survenir et permet de mieux connaître le problème du squeaking et ses conséquences / The aim of the study done in this thesis was to enhance the knowledge in the use of ceramic on ceramic bearing for cementless total hip arthroplasty. A clinical study of 100 cementless total hip arthroplasty at 9 years of follow-up showed the reliability of ceramic in terms of wear, biocompatibility and osseointegration. Subsequently, the comparison of the method for implantation of the implants (press-fit with or without additional screws fixations) showed that the stiffness of ceramic was not inconsistent with a simple impaction, for patients who do not present bone fragility. We then studied a particular complication of ceramic bearing, the squeaking noise. An in vitro study of this phenomenon, allowed us to reproduce squeaking in lubricated conditions, with the presence of a third metal body between the frictions surfaces, suggesting the importance on lubrication damages in the genesis of this phenomenon. Analysis of explants has confirmed our hypothesis, highlighting the importance of implant design, to avoid impingement, potentially generating metal particles. Finally, the long-term analysis of squeaking phenomenon showed its low impact on implant survival and patient’s quality of life. This work, which involved clinical and biomechanical analysis, confirms the interest for the use of ceramics bearings in total hip arthroplasty, emphasizes the importance of implant design and implant positioning, to avoid complications, and helps for a better understanding with the problem of squeaking and its consequences
55

Perception de la parole dans le bruit au cours du vieillissement normal : études de stimulation magnétique transcrânienne

Brisson, Valérie 17 July 2024 (has links)
Le vieillissement normal s'accompagne de difficultés à suivre les conversations dans les environnements exigeants, par exemple en présence de bruit ou de plusieurs locuteurs. Cet obstacle à la communication augmente le risque d'isolement social. Les aides auditives sont souvent insuffisantes pour réduire adéquatement ces difficultés, suggérant l'implication de mécanismes centraux. L'étiologie complexe de ce déclin demeure incertaine, ce qui limite le développement de nouvelles stratégies pour prévenir ou réduire ces difficultés prévalentes. Des études récentes ont suggéré que le vieillissement de la voie dorsale du langage pourrait être impliqué dans la réduction des capacités de perception de la parole chez les aînés. Ce réseau est notamment responsable de l'analyse acoustique (gyrus temporal supérieur ; STG), phonologique (sulcus temporal supérieur ; STS) et articulatoire (cortex prémoteur ventral ; PMv) de la parole. La contribution de chacune de ces étapes d'analyse au déclin de la perception de la parole chez les aînés demeure toutefois inconnue. La stimulation magnétique transcrânienne (TMS) permet de moduler l'excitabilité corticale et de produire des changements dans des tâches comportementales, incluant des tâches langagières. L'utilisation de la TMS pour augmenter l'excitabilité corticale dans les aires impliquées dans le traitement de la parole pourrait réduire les difficultés de perception de la parole fréquemment rapportées chez les aînés. Toutefois, très peu d'études de neurostimulation ont été réalisées chez les personnes âgées, ce qui limite les connaissances sur le potentiel de ces méthodes pour induire des changements dans le cerveau vieillissant. L'objectif général de cette thèse consistait à déterminer si la TMS excitatrice appliquée à des régions impliquées dans le traitement de la parole pouvait améliorer la performance en perception de la parole dans le bruit chez l'adulte en santé. Le sous-objectif était d'identifier les facteurs qui influencent la réponse à la TMS, dont l'âge, la performance de base, la région stimulée, la variabilité du locuteur et les caractéristiques des régions stimulées (épaisseur corticale et force du signal BOLD). Pour répondre à ces objectifs, deux études ont été réalisées. L'étude 1a incluait l'élaboration d'un test de discrimination de syllabes accompagnée d'un bruit de parole, validé auprès de 21 participant.e.s en santé âgé.e.s de 20 à 85 ans. L'étude 1b incluait des séances de TMS excitatrice (théta-burst intermittentes) au STS et au PMv à partir d'images anatomiques IRM individuelles, auprès d'un second échantillon de 34 participant.e.s âgé.e.s de 32 à 79 ans. Une séance de stimulation placebo (sham) a été effectuée pour obtenir une mesure de performance de base. L'étude 2 incluait 30 participant.e.s âgé.e.s de 21 à 78 ans. Des séances de TMS excitatrices ont été appliquées au vertex (séance sham), au STG, au STS et au PMv en fonction des pics d'activité individuels mesurés durant une séquence d'imagerie magnétique fonctionnelle (1 visite pour l'imagerie et 2 visites pour les séances de TMS). La tâche de discrimination de syllabes dans le bruit incluait deux conditions: dans l'une d'elles, un seul locuteur produisait tous les stimuli (locuteur fixe), alors que dans l'autre, huit locuteurs variaient à travers les essais et à l'intérieur d'un même essai (locuteurs multiples). Les résultats des deux études démontrent un effet négatif de l'âge sur la performance au test de perception de la parole dans le bruit, indépendamment de mesures de l'audition et de la cognition. De plus, l'étude 2 a montré une interaction entre l'âge et la variabilité qui suggérait une réduction de la capacité de normalisation du locuteur chez les aînés. Les analyses des différences de score post-TMS ont révélé que les individus présentant plus de difficultés à la performance de base bénéficient plus de la TMS. De plus, une interaction entre l'âge et l'épaisseur corticale a été observée : les adultes âgés présentant une épaisseur corticale plus faible démontraient de meilleurs bénéfices post-TMS, et cette relation était inversée chez les jeunes adultes. Ces résultats confirment le rôle de la voie dorsale dans les habiletés de PPB et suggèrent qu'une augmentation de l'excitabilité corticale dans ce réseau peut réduire les difficultés de PPB chez l'adulte, mais que le bénéfice potentiel de cette méthode dépend de l'âge et de l'état structurel de ce réseau. Ces connaissances sont essentielles au développement d'interventions basées sur la neurostimulation pour réduire les obstacles à la communication dans la population adulte. / Normal aging is associated with difficulties following conversations in demanding environments, such as in the presence of noise or multiple talkers. These prevalent difficulties hinder communication and increase the risk of social isolation. Hearing aids often prove insufficient in adequately reducing these difficulties, suggesting the involvement of central mechanisms. The etiology of this decline remains uncertain, limiting the development of new strategies to prevent or alleviate these prevalent difficulties. Recent studies have suggested that aging in the dorsal language pathway may be implicated in the reduction of speech perception abilities in older individuals. This network is notably responsible for the acoustic (superior temporal gyrus; STG), phonological (superior temporal sulcus; STS), and articulatory (ventral premotor cortex; PMv) processing of speech. However, the contribution of each of these speech processing stages to speech perception decline in older individuals remains unknown. Transcranial Magnetic Stimulation (TMS) can modulate cortical excitability and induce changes in behaviour, including language-related behaviours. Using TMS to increase cortical excitability in areas involved in speech processing could reduce the reported speech perception difficulties in older individuals. However, very few neurostimulation studies have been conducted in the elderly, limiting our understanding of the potential of these methods to induce changes in the elder brain. The overall objective of this thesis was to determine if faciliatory TMS applied to regions involved in speech processing could improve speech perception in noise (SPiN) performance in healthy adults. The secondary objective was to identify the factors that influence the response to TMS, including age, baseline performance, talker variability, target region, and their characteristics (cortical thickness and BOLD signal strength). To address these objectives, two studies were conducted. Study 1a involved the development of a syllable discrimination test in speech noise, validated with 21 healthy participants aged 20 to 85. Study 1b included sessions of excitatory TMS (intermittent theta-burst) to the STS and PMv based on individual MRI anatomical images, with a second sample of 34 participants aged 32 to 79. A placebo (sham) stimulation session was performed to obtain a baseline performance measure. Study 2 included 30 participants aged 21 to 78. Faciliatory TMS sessions were applied to the vertex (sham session), STG, STS, and PMv based on individual activity peaks measured during a functional magnetic resonance imaging (fMRI) sequence (1 MRI visit and 2 TMS visits). The syllable discrimination task in noise included two conditions: in one, a single talker produced all stimuli (fixed talker), while in the other, eight talkers varied across trials and within the same trial (multiple talkers). The results of both studies demonstrate a negative effect of age on performance in the SPiN test, independent of hearing and cognitive measures. Furthermore, Study 2 showed an interaction between age and variability on performance, suggesting a reduction in the older individuals' ability to normalize talker variability. Post-TMS difference score analyses revealed that individuals with more difficulty in baseline performance benefited more from TMS. Additionally, an interaction between age and cortical thickness was observed: older adults with lower cortical thickness showed greater post-TMS benefits, while this association was reversed in younger adults. These results confirm the role of the dorsal pathway in speech perception abilities and suggest that increasing cortical excitability in this network can reduce speech perception difficulties in adults, but the extend of the benefit will vary according to age and structural state of this network. This knowledge is essential for the development of neurostimulation-based interventions to reduce communication barriers in the adult population.
56

Déterminants hémodynamiques de l'hypertension pulmonaire et de la thromboembolie suite au remplacement valvulaire mitral : étude in-vitro sur un simulateur atrio-ventriculaire gauche et pulmonaire

Tanné, David 16 April 2018 (has links)
Les maladies valvulaires mitrales induisent une surcharge de pression ou de volume dans l’oreillette. L’augmentation de la pression auriculaire initie alors des complications secondaires, telles que l’hypertension artérielle pulmonaire, la fibrillation auriculaire et la thromboembolie. Les objectifs du remplacement valvulaire mitral sont donc d’améliorer l’hémodynamie de la valve, mais aussi de normaliser les pathologies secondaires. Ces objectifs ne sont pas nécessairement atteints chez tous les patients. Parfois, ils ne le sont que partiellement. L’objectif général de cette thèse est de mieux comprendre les interactions complexes entre le substitut valvulaire, les écoulements intra-auriculaires et la circulation pulmonaire. Nous avons donc développé un nouveau simulateur expérimental atrio-ventriculaire capable d’estimer ces interactions. Il est basé sur le respect du synchronisme entre les contractions et relaxations des deux cavités cardiaques, modélisées par deux moules en silicone. Deux pompes, asservies par un contrôleur temps réel, autorisent une double activation rigide et synchronisée, et la maîtrise des volumes des moules de l’oreillette et du ventricule. Un modèle Windkessel simule la circulation pulmonaire et une troisième pompe l’éjection du ventricule droit. Les courbes pression-volume des cavités et les impédances aortique et pulmonaire mesurées sur le simulateur sont totalement physiologiques, excepté l’amplitude de la pression auriculaire qui demeure encore trop élevée. La forme du moule de l’oreillette, totalement anatomique et comprenant quatre veines pulmonaires et l’appendice auriculaire gauche, permet une organisation de l’écoulement intra-auriculaire très proche de celle observée in-vivo. La visualisation de ces écoulements est réalisée par vélocimétrie par images de particules trois composantes et multi-plans, associée à une méthode de masquage automatique des régions d’intérêt. Nous avons étudié, par une approche numérique, l’impact de la disproportion patient-prothèse en position mitrale sur les pressions auriculaire gauche et artérielle pulmonaire. Le modèle numérique a permis de valider les seuils d’aire valvulaire effective indexée utilisés en clinique pour estimer la présence et la sévérité de la disproportion patient-prothèse. Par ailleurs, nous avons démontré au moyen du simulateur atrio-ventriculaire que l’aire valvulaire effective d’une prothèse mitrale varie de l’ordre de 30% durant la diastole, ce qui remet en cause l’hypothèse selon laquelle cette variable ne change pas durant cette période. Enfin, nous avons mis en évidence l’impact positif de la régurgitation d’une prothèse mécanique sur la thrombogénèse, similairement à l’insuffisance mitrale, au détriment d’une augmentation de la pression artérielle pulmonaire. Les nouvelles connaissances et le nouvel outil expérimental présentés dans cette thèse pourraient être utilisés, à l’avenir, pour améliorer les prothèses valvulaires mitrales et développer des stratégies visant à optimiser les résultats du remplacement valvulaire mitral. / Mitral valve diseases induce left atrial pressure or volume overload. The resulting increase of left atrial pressure, in turn, leads to secondary abnormalities, such as pulmonary arterial hypertension, atrial fibrillation and thromboembolism. Therefore, the main goals of mitral valve replacement are to restore the valvular hemodynamics and to normalize the secondary abnormalities. The general objective of this thesis is to better understand the complex interactions between the valve substitute, the intra-atrial flow patterns, and the pulmonary circulation. We, therefore, developed a new in-vitro pulsed atrio-ventricular mock circulatory system to investigate these interactions. The setup is based on the perfect synchronization between the contractions and relaxations of the two cardiac cavities, which are mimicked by two silicone moulds. Two pumps, real time servo-controlled, allow the double rigid and synchronized activations of the moulds, and the control of left atrial and left ventricular volumes. A Windkessel model is used as the pulmonary circulation and a third pump mimick the right ventricular ejection. Pressure-volume curves of the cardiac cavities and aortic and pulmonary impedances, measured in-vitro, are totally concordant with the cardiac physiology, except the amplitude of the left atrial pressure which remains too elevated. The anatomical shape of the left atrial mould includes the four pulmonary veins and the left atrial appendage. This realistic geometry allows flow patterns very closed to those observed in-vivo. Their visualization is performed using multi-planes three components particle image velocimetry, associated with an automatic mask generation. Using a numerical approach, we investigated the impact of mitral prosthesis-patient mismatch on left atrial and pulmonary arterial pressures. The numerical model was used to validate the cut-off values of indexed effective orifice areas generally used to define the presence and the severity of prosthesis-patient mismatch in the clinical setting. With the use of the mock circulatory system, we showed that the effective orifice area of mitral prostheses may exhibit variations of ±30% during diastole, which contradicts the previous hypothesis stating that this variable remains constant during this period. Finally, we described the positive impact of the mechanical mitral prosthetic valve regurgitation on thrombogenesis, similarly to mitral insufficiency, to the expense of an increase of the pulmonary arterial pressure. The new knowledge and the new experimental setup presented in this thesis may prove to be useful to optimize the design of mitral prosthetic valves and the performance of mitral valve replacement.
57

Étude transversale sur l’asepsie des articles transférés entre la clinique et le laboratoire dentaire et de l’instrumentation de laboratoire

Bezerianos, Joanna 09 1900 (has links)
Les mesures de contrôle de la contamination croisée sont principalement concentrées dans la salle opératoire dentaire alors que les articles transférés entre la clinique et le laboratoire dentaire et les instruments de laboratoire ont reçu peu d’attention. Cette étude vise à documenter l’application des mesures d’asepsie sur ces articles par les professionnels du domaine dentaire ainsi que leurs perceptions entourant ces mesures. Un questionnaire autoadministré et anonyme a été envoyé à un échantillon aléatoire des dentistes, denturologistes et directeurs de laboratoire dentaire qui étaient inscrits aux listes des ordres professionnels en juin 2008 dans la province de Québec. Des 1100 questionnaires envoyés, 376 ont été retournés remplis. Presque trois quarts (72,1 %) des répondants affirment faire l’asepsie des instruments de laboratoire et 74,9 %, la désinfection des articles transférés mais avec des pourcentages variables selon le groupe d’articles (empreintes, prothèses, etc.). Seulement 9,1 % de professionnels identifient de façon générale les articles désinfectés avant l’envoi. Plus de la moitié des professionnels (51,4 %) trouvent qu’ils n’ont pas assez d’information sur l’asepsie des articles transférés et 62,4 %, qu’elle est difficile à appliquer. Cette étude est la première réalisée auprès des trois groupes de professionnels et la première à étudier leurs perceptions entourant l’asepsie des articles transférés et de l’instrumentation de laboratoire. Nous avons démontré que l’application des mesures d’asepsie à ces articles par les professionnels du domaine dentaire n’est pas toujours conforme aux normes proposées et qu’il existe un besoin de renforcer leur application, surtout en ce qui a trait aux articles transférés. / Infection control practices have been mainly concentrated in the dental operatory whereas the articles transferred between the dental clinic and the dental laboratory as well as laboratory instruments have received less attention. This study attempts to document the practices of dental care professional implicated in the fabrication of dental prosthesis as to the asepsis of these items as well as their perceptions towards it. In June 2008 an auto-administrated and anonymous questionnaire was sent to a random sample of dentists, denturologists and dental laboratory directors licensed to practice in the province of Quebec (Canada). From the 1,100 questionnaires sent, 376 were returned filled-in. Almost two thirds of responders (72.1%) claim to disinfect or sterilize laboratory instruments and 74.9% to disinfect transferred articles, with percentages varying according to the group of articles (impressions, prosthesis, etc.). However, only 9.1% regularly identify disinfected work. More than half of the responders (51.4%) think it is difficult to apply a form of asepsis on transferred articles and 62.4% believe there is a lack of information towards it. This study is the first to have been addressed simultaneously to the three groups of professionals and the first to question them on their perceptions. It demonstrated that the application of asepsis measures to transferred articles and laboratory instruments by dental care professionals is not always complying with existing recommendations. There is a need to reinforce their application, especially of asepsis measures on transferred articles.
58

Development and evaluation of a research-based prosthodontic clinical record

Ahmadi, Motahareh 04 1900 (has links)
Introduction: Bien que l'importance de transférer les données de la recherche à la pratique a été largement démontrée, ce processus est toujours lent et fait face à plusieurs défis tels que la conceptualisation des évidences, la validité interne et externe de la recherche scientifique et les coûts élevés de la collecte de grandes quantités de données axées sur le patient. Les dossiers dentaires des patients contiennent des renseignements valables qui donneraient aux chercheurs cliniques une opportunité d'utiliser un large éventail d'informations quantitatives ou qualitatives. La standardisation du dossier clinique permettrait d’échanger et de réutiliser des données dans différents domaines de recherche. Objectifs: Le but de cette étude était de concevoir un dossier patient axé sur la recherche dans le domaine de la prosthodontie amovible à la clinique de premier cycle de l’Université de Montréal. Méthodes: Cette étude a utilisé des méthodes de recherche-action avec 4 étapes séquentielles : l'identification des problèmes, la collecte et l'interprétation des données, la planification et l’évaluation de l'action. Les participants de l'étude (n=14) incluaient des professeurs, des chercheurs cliniques et des instructeurs cliniques dans le domaine de la prosthodontie amovible. La collecte des données a été menée à l’aide d’une revue de littérature ciblée et complète sur les résultats en prosthodontie ainsi que par le biais de discussions de groupes et d’entrevues. Les données qualitatives ont été analysées en utilisant QDA Miner 3.2.3. Résultats: Les participants de l'étude ont soulevé plusieurs points absents au formulaire actuel de prosthodontie à la clinique de premier cycle. Ils ont partagé leurs idées pour la conception d'un nouveau dossier-patient basé sur 3 objectifs principaux: les objectifs cliniques, éducatifs et de recherche. Les principaux sujets d’intérêt en prosthodontie amovibles, les instruments appropriés ainsi que les paramètres cliniques ont été sélectionnés par le groupe de recherche. Ces résultats ont été intégrés dans un nouveau formulaire basé sur cette consultation. La pertinence du nouveau formulaire a été évaluée par le même groupe d'experts et les modifications requises ont été effectuées. Les participants de l'étude ont convenu que le cycle de recherche-action doit être poursuivi afin d'évaluer la faisabilité d’implémentation de ce dossier modifié dans un cadre universitaire. Conclusion: Cette étude est une première étape pour développer une base de données dans le domaine de la prothodontie amovible. La recherche-action est une méthode de recherche utile dans ce processus, et les éducateurs académiques sont bien placés pour mener ce type de recherche. / Introduction: Although the importance of research translating into practice has been widely recognized, this process is still slow and faces several barriers such as conceptualizations of evidence, internal and external validity of the evidence and high costs of providing large amounts of patient-based outcome data. Patient’s dental records contain valuable information that would give clinical researchers an opportunity to use a wide range of quantitative or qualitative information. Standardization of clinical record would allow the interoperability and reusability of data in different research fields. Objectives: The aim of this study was to design a research-based patient record in the field of removable prosthodontics in the undergraduate clinic of the “Université de Montréal.” Methods: This study used action research methods with 4 sequential steps: problem identification, gathering and interpreting data, action planning, and action evaluation. Study participants included professors, clinical researchers, and clinical instructors in the field of removable prosthodontics. Data collection consisted of a comprehensive literature review on prosthodontic outcomes as well as focus-group discussions and interviews. The qualitative data were analysed using QDA Miner 3.2.3. Results: The study participants raised several concerns about the deficiencies of the existing patients’ prosthodontic record in the undergraduate clinic. They shared their ideas for designing a new patient record based on 3 key objectives: clinical, educational, and research objectives. The prosthodontic outcomes of interest and appropriate instruments as well as the clinical parameters were selected by the research group and were integrated into a new research-based record. The appropriateness of the new record has been evaluated by the same panel of experts and the necessary modifications have been carried out. The study participants agreed that the action research cycle should be continued to evaluate the feasibility of the implementation of this redesigned record in the university-based setting. Conclusion: This study is a beginning effort to develop a database in the field of removable prosthodontics. Action research is a useful research method in this process, and academic educators are well placed to conduct such research.
59

Evaluation multimodale du processus de cicatrisation des dispositifs de fermeture percutanée des communications inter-atriales / Multimodal assessment of the healing process of atrial septal defect percutaneous closure devices

Jalal, Zakaria 14 November 2018 (has links)
La fermeture percutanée est le traitement de référence des communications interatriales (CIA). Après son implantation, une cicatrisation du dispositif est classiquement attendue après quelques mois ; il semble cependant qu’un recouvrement incomplet ou partiel puisse être observé dans de rares cas, sans que l’on en connaisse les mécanismes impliqués. Cette cicatrisation imparfaite du dispositif est associée à la survenue de complications retardées. Dans le cadre de cette thèse nous avons étudié la cicatrisation de ces prothèses de CIA, en nous focalisant sur les processus de recouvrement et d’endothélialisation des dispositifs, à travers une approche translationnelle incluant expérimentations in vitro, modèle animal chronique et étude clinique. A la fin de ce travail, il est possible de conclure que : 1) il existe des cas de complications au long cours après fermeture de CIA, liées à un défaut de recouvrement du dispositif, 2) sur une large cohorte pédiatrique avec un suivi allant jusqu’à 18 ans après l’implantation, l’incidence de ces complications est faible 3) les modèles animaux, utilisés seuls, ne peuvent suffire à expliquer ni à avancer dans la compréhension de ce phénomène, 4) il n’existe pas de différences significatives concernant le processus de recouvrement entre les 3 prothèses analysées au cours de ce travail, 5) une évaluation non invasive et individualisée du recouvrement prothétique , grâce aux techniques d’imagerie, est une perspective prometteuse. Ces données montrent qu’une meilleure compréhension du processus de recouvrement prothétique passe par la réalisation conjointe d’études fondamentales et cliniques. Cependant, le développement d’outils permettant une évaluation individualisée du recouvrement doit être poursuivi, du fait de leur fort potentiel de translation clinique et de leur capacité à optimiser la prise en charge du patient. / The percutaneous device closure is the gold treatment of atrial septal defect (ASD). After implantation, device healing is classically expected following several months; however, an incomplete or partial covering of the device may be observed without a full knowledge of the underlying mechanisms. In this thesis we studied the healing of these intracardiac prostheses, focusing on the covering and endothelialization processes of devices, approach through a translational approach including in vitro experiments, chronic animal model and clinical study. At the end of this work, it is possible to conclude that 1) there are cases of long-term complications after closure of CIA, related to a lack of recovery of the device, 2) in a large cohort of pediatric with a follow up of up to at 18 years after implantation, the incidence of these complications is low 3) animal models, used alone, can not suffice to explain or improve the understanding of this complex process, 4) there is no significant differences in the covering process between the 3 prostheses analyzed during this work, 5) a non-invasive and individualized assessment of prosthetic recovery, using imaging techniques, is a promising perspective with significant potential for clinical translation . These data show that a better understanding of device healing process needs the joint undertake of basic and clinical studies. Moreover, the development of tools for individualized assessment of device covering should be pursued in parallel, due to their high translational potential, in order to optimize patient management.
60

Étude comparative de méthodes ultrasonores non linéaires appliquées à des modèles expérimentaux de scellement et/ou d'ostéointégration de prothèses

Rivière, Jacques 16 December 2012 (has links) (PDF)
Ce travail de thèse s'inscrit dans la perspective à long terme d'implémenter in vivo de nouvelles méthodes non invasives de contrôle du scellement ou de l'ostéointégration de prothèses osseuses (implants dentaires, prothèses de hanche). Bien qu'étant la plus utilisée cliniquement, la radiographie à rayons X souffre d'une faible sensibilité. Le potentiel de méthodes développées ces vingt dernières années et fondées sur des mesures d'élasticité, a été démontré in vitro, mais leur efficacité in vivo est encore sujette à caution. Notre objectif a été d'évaluer le potentiel de nouvelles méthodes basées sur la mesure de la réponse élastique non linéaire, méthodes qui sont apparues dans les domaines de la géophysique et du contrôle non destructif, et qui ont montré une plus grande sensibilité que la réponse linéaire élastique à la présence de contacts faibles au sein d'une structure rigide, tels que les fissures. Pour cela, plusieurs modèles d'ostéointégration et de scellement (avec conditions aux limites ou conditions d'amortissement variées) ont donc été étudiés expérimentalement à l'aide de différentes techniques d'élasticité non linéaire. Au final, cette étude expérimentale a permis l'extraction des paramètres non linéaires les plus prometteurs et d'évaluer leurs avantages et limites respectifs en vue de leur application in vivo.

Page generated in 0.3655 seconds