• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 1
  • Tagged with
  • 23
  • 23
  • 20
  • 20
  • 12
  • 10
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo eletroanalítico e cromatográfico para a análise de LSD em química forense / Electroanalytical and chromatographic studies for determination of LSD in forensic chemistry.

Oiye, Érica Naomi 27 November 2015 (has links)
O LSD, abreviação para a dietilamida do ácido lisérgico, é um alucinógeno que comumente é consumido na forma de selos e suas apreensões são constantes no cenário policial brasileiro e mundial. No momento da apreensão, nos laboratórios forenses tem-se um processo de análises químicas para a confirmação desta droga. As metodologias analíticas precisam ser sensíveis, específicas e fornecer resultados confiáveis, o que o processo de validação através de protocolos normatizados - pode garantir. Neste trabalho, propõem-se procedimentos experimentais para a determinação de LSD em amostras apreendidas através de técnicas de Voltametria Cíclica e Cromatografia Líquida de Alta Eficiência (CLAE) com detecções de arranjo de diodo e eletroquímica. Essas análises permitem ampliar as restritas metodologias encontradas na literatura. Esses procedimentos tiveram o perclorato de amônio em metanol com presença de água como eletrólito de suporte para a detecção voltamétrica, e com base nesses resultados, obteve-se informações para a detecção eletroquímica dentro do sistema cromatográfico. Esta mesma composição de fase móvel também permite a detecção por arranjo de diodo neste sistema. Nos três sistemas estudados, obteve os limites de quantificação de 1,64 10-6 mol L-1, 6,67 10-6 mol L-1 e 3,29 10-6 mol L-1 para as técnivas de Voltametria Cíclica, CLAE com detecção eletroquímica e detecção de arranjo de diodo, respectivamente. Tais valores mostram que as metodologias tem capacidade de analisar baixas concentrações de LSD. Além da validação dos três métodos propostos, fez-se a análise de três amostras apreendidas, das quais uma continha LSD e outras duas não. Deste modo, a partir da combinação dos mesmos componentes de fase móvel, é possível obter dois procedimentos cromatográficos baseados em diferentes tipos de detecção, enquanto que a determinação voltamétrica habilita outro tipo de análise aliando a portabilidade e rapidez da quantificação. Ao fim de todo o processo de validação envolvido, obtêm-se três metodologias que permitem a quantificação de LSD, com a confiabilidade garantida para serem aplicadas em análises de rotina de um laboratório forense. / LSD abbreviation for Lysergic Acid Diethylamide - is a hallucinogenic drug commonly consumed in blotters form. Inside the police scenario, its apprehension is constant in national and global scale. Once the drug is apprehended, forensic laboratories must follow a procedure with chemical analysis aiming a confirmatory result. The analytical methodologies applied for this purposes must be sensitive, specific and provide reliable results, and all these characteristics can be afforded with a validation process behind these procedures. In the present study, three new methodologies for the determination of LSD in seized samples are presented, based on Cyclic Voltammetry technique and High Performance Liquid Chromatography (HPLC) with diode array detection and electrochemical detection. These analyses increase the number of methodologies found in literature for the same purpose. All the experimental procedures included ammonium perchlorate in methanol with the presence of water composing the supporting electrolyte solution for voltammetric measurements. From the electrochemical information observed, it could be applied for electrochemical detection in a chromatographic system. This same composition as mobile phase enables a signal for diode array detection. In all the three systems, the values for limit of quantification were 1.64 10-6 mol L-1, 6.67 10-6 mol L-1 and 3.29 10-6 mol L-1, for voltammetric determination, HPLC with electrochemical detector and diode array detector, respectively. These results prove the methodologies can quantify low concentration of LSD in seized samples. Indeed, after all validation process, three real blotter samples were analyzed, which one of them contained LSD. In this way, from the same components in mobile phase, it is possible to gather two different procedures based on distinct detection principle, whilst the voltammetric determination might be seen as a variety for drug analysis, with portability and quickness as some characteristics for its quantification. Finally, after all validation process applied, there are three methodologies for quantification of LSD in seized samples, with confidence ensured for appliance in the routine of a forensic laboratory.
12

Estudo eletroanalítico e cromatográfico para a análise de LSD em química forense / Electroanalytical and chromatographic studies for determination of LSD in forensic chemistry.

Érica Naomi Oiye 27 November 2015 (has links)
O LSD, abreviação para a dietilamida do ácido lisérgico, é um alucinógeno que comumente é consumido na forma de selos e suas apreensões são constantes no cenário policial brasileiro e mundial. No momento da apreensão, nos laboratórios forenses tem-se um processo de análises químicas para a confirmação desta droga. As metodologias analíticas precisam ser sensíveis, específicas e fornecer resultados confiáveis, o que o processo de validação através de protocolos normatizados - pode garantir. Neste trabalho, propõem-se procedimentos experimentais para a determinação de LSD em amostras apreendidas através de técnicas de Voltametria Cíclica e Cromatografia Líquida de Alta Eficiência (CLAE) com detecções de arranjo de diodo e eletroquímica. Essas análises permitem ampliar as restritas metodologias encontradas na literatura. Esses procedimentos tiveram o perclorato de amônio em metanol com presença de água como eletrólito de suporte para a detecção voltamétrica, e com base nesses resultados, obteve-se informações para a detecção eletroquímica dentro do sistema cromatográfico. Esta mesma composição de fase móvel também permite a detecção por arranjo de diodo neste sistema. Nos três sistemas estudados, obteve os limites de quantificação de 1,64 10-6 mol L-1, 6,67 10-6 mol L-1 e 3,29 10-6 mol L-1 para as técnivas de Voltametria Cíclica, CLAE com detecção eletroquímica e detecção de arranjo de diodo, respectivamente. Tais valores mostram que as metodologias tem capacidade de analisar baixas concentrações de LSD. Além da validação dos três métodos propostos, fez-se a análise de três amostras apreendidas, das quais uma continha LSD e outras duas não. Deste modo, a partir da combinação dos mesmos componentes de fase móvel, é possível obter dois procedimentos cromatográficos baseados em diferentes tipos de detecção, enquanto que a determinação voltamétrica habilita outro tipo de análise aliando a portabilidade e rapidez da quantificação. Ao fim de todo o processo de validação envolvido, obtêm-se três metodologias que permitem a quantificação de LSD, com a confiabilidade garantida para serem aplicadas em análises de rotina de um laboratório forense. / LSD abbreviation for Lysergic Acid Diethylamide - is a hallucinogenic drug commonly consumed in blotters form. Inside the police scenario, its apprehension is constant in national and global scale. Once the drug is apprehended, forensic laboratories must follow a procedure with chemical analysis aiming a confirmatory result. The analytical methodologies applied for this purposes must be sensitive, specific and provide reliable results, and all these characteristics can be afforded with a validation process behind these procedures. In the present study, three new methodologies for the determination of LSD in seized samples are presented, based on Cyclic Voltammetry technique and High Performance Liquid Chromatography (HPLC) with diode array detection and electrochemical detection. These analyses increase the number of methodologies found in literature for the same purpose. All the experimental procedures included ammonium perchlorate in methanol with the presence of water composing the supporting electrolyte solution for voltammetric measurements. From the electrochemical information observed, it could be applied for electrochemical detection in a chromatographic system. This same composition as mobile phase enables a signal for diode array detection. In all the three systems, the values for limit of quantification were 1.64 10-6 mol L-1, 6.67 10-6 mol L-1 and 3.29 10-6 mol L-1, for voltammetric determination, HPLC with electrochemical detector and diode array detector, respectively. These results prove the methodologies can quantify low concentration of LSD in seized samples. Indeed, after all validation process, three real blotter samples were analyzed, which one of them contained LSD. In this way, from the same components in mobile phase, it is possible to gather two different procedures based on distinct detection principle, whilst the voltammetric determination might be seen as a variety for drug analysis, with portability and quickness as some characteristics for its quantification. Finally, after all validation process applied, there are three methodologies for quantification of LSD in seized samples, with confidence ensured for appliance in the routine of a forensic laboratory.
13

Desenvolvimento de sensores voltamétricos e piezelétricos modificados quimicamente com cucurbiturilas para análises de cocaína em amostras de interesse forense / Development of voltammetric and piezoelectric sensors chemically modified with cucurbiturils for analysis of cocaine in samples of forensic interest.

Menezes, Matheus Manoel Teles de 14 November 2014 (has links)
Considerando a relevância dos trabalhos onde se utiliza eletrodos quimicamente modificados e o pequeno número de estudos envolvendo cocaína e seus interferentes (cafeína, teobromina e lidocaína), por técnicas eletroquímicas ou piezelétricas, este estudo tem como objetivo o desenvolvimento de eletrodos de ouro e platina quimicamente modificados com compostos da classe das cucurbiturilas (CB[5], CB[6] e CB[7]) para a detecção de cocaína. A técnica de microbalança de cristal de quartzo foi empregada a fim de se estudar cocaína padrão e seus interferentes, em fase gasosa. Os eletrodos de ouro foram quimicamente modificados com cucurbiturilas e o modificador CB[6] apresentou os melhores resultados. Medidas por voltametria cíclica foram realizadas utilizando-se um potenciostato Autolab III acoplado a um computador, com eletrodo de ouro e platina atuando como eletrodo de trabalho, Ag/AgCl como eletrodo de referência e eletrodo espiral de platina como eletrodo auxiliar, com velocidade de varredura de 0,1 V.s-1 (100 mV.s-1). Os parâmetros voltamétricos foram otimizados para tornar as análises mais rápidas e sensíveis sem perda de qualidade ou intensidade do sinal voltamétrico. O eletrodo de platina quimicamente modificado com filme de cucurbit[6]urila apresentou aumento da corrente de pico catódica quando estudado frente à cocaína, teobromina e lidocaína. Análises com eletrodo de platina sem modificador químico apresentaram limite de detecção de 4,14.10-6 mol.L-1 e limite de quantificação de 1,38.10-5 mol.L-1 , para a cocaína, e na presença do modificador químico CB[6] apresentou limite de detecção de 1,36.10-6 mol.L-1 e limite de quantificação de 4,54.10-6 mol.L-1 . Eletrodos de ouro com ou sem a presença de modificadores químicos não apresentaram sinal para nenhum analito. / Considering the importance of chemically modified electrodes and the small amount of the cocaine study and their interfering (caffeine, theobromine and lidocaine) using electrochemical and piezoelectric techniques, this study aims to investigate the development of the gold and platinum electrodes chemically modified by cucurbiturils (CB[5], CB[6] and, CB[7]) in order to detect cocaine. The Quartz Crystal Microbalance technique was employed in order to study in gas phase the standard samples of cocaine and their interfering. Gold electrode was chemically modified with cucurbiturils films and the CB[6] modifier showed the best results. The cyclic voltammetric measurements were performed using a Autolab III potentiostat coupled to a computer, being gold and platinum as the working electrode, Ag/AgCl as the reference electrode and platinum wire as counter electrode, using a scan rate of 0,1 V.s-1 (100 mV.s-1). The voltammetric parameters were optimized in order to make the analysis faster and more sensitive without loss of intensity and quality of the voltammetric signal. The platinum electrode modified by cucurbit[6]uril film showed an increase of cathodic current peak when electrode was exposed to cocaine, theobromine and lidocaine. Analysis employed platinum working electrode without chemical modifier showed a detection limit of 4.14 . 10-6 mol.L-1 and quantification limit of 1.38 . 10-5 mol.L-1 for cocaine and with chemical modifier CB[6] showed a detection limit of 1.36 . 10-6 mol.L-1 and quantification limit of 4.54 . 10-6 mol.L-1 . Gold electrodes with or without chemical modifiers showed no response for any analyte.
14

Desenvolvimento de métodos voltamétricos para a quantificação de LSD utilizando-se o eletrodo de pasta de carbono modificado com complexo de base de Schiff / Development of voltammetric methods for the quantification of LSD using a carbon paste electrode modified by a Schiff base complex

Ribeiro, Maria Fernanda Muzetti 29 October 2015 (has links)
Nos últimos anos, vários métodos eletroanalíticos foram desenvolvidos a fim de tornarem mais práticas e acessíveis às análises químicas de substâncias entorpecentes realizadas pela polícia científica. Com a sensibilidade e seletividade compatíveis com as dos métodos instrumentais convencionais, é a portabilidade da técnica eletroanalítica que se sobressai e tem apresentado grande potencial para tais aplicações. O uso de complexos metálicos com as bases de Schiff como modificadores do eletrodo de trabalho, tornou ainda mais promissora a utilização destes métodos para a detecção e quantificação de entorpecentes. Os eletrodos de pasta de carbono também contribuem para a praticidade da eletroanalítica, uma vez que são produzidos de forma simples e barata. Desta forma, neste projeto foram desenvolvidos métodos voltamétricos para a quantificação da dietilamida do ácido lisérgico (LSD), utilizando-se o eletrodo de pasta de carbono modificado com o complexo [UO2(Ac-ophen)]·H2O. A aplicação do KCl como eletrólito suporte, em solução aquosa, diferencia estes métodos do encontrado na literatura. Nas análises, foram empregadas as técnicas de voltametria cíclica, onda quadrada e de pulso diferencial. A linearidade no aumento da corrente frente às variações da concentração do LSD possibilitou a obtenção das curvas analíticas com desvio padrão e limites de detecção e quantificação de 2,45, 0,62 e 1,02 mol L-1, respectivamente, como melhores resultados. As análises de recuperação das amostras, 103 e 108%, demostra a possibilidade da utilização destas no âmbito forense. / The development of electroanalytical methods for forensic science has been growing in recent years by the fact of their practicality and low cost. Once sensibility and selectivity values are compatible to conventional methods, as chromatography and spectrometry, the portability of this system consists on interesting advantages. The simple modification of the carbon paste working electrode with Schiff bases complexes became even more promising to use this method for the detection and quantification of narcotics. The carbon paste electrode itself contributes for the practicality of the analyses, once it is made of simple carbon powder, which can be disposable. This project aimed to develop voltammetric methods for the quantification of the lysergic acid diethylamide (LSD) using a carbon paste electrode modified with the complex [UO2(Ac-ophen)]·H2O. The use of aqueous solution of KCl as supporting electrolyte characterizes a less pollutant methodology, differently of other methods that still use toxic solvents The combination of the differential pulse and square wave voltammetries with the modified carbon paste was crucial for the detection of trace levels of the LSD. The linear response in various concentrations of LSD results on analytical curves with standard deviation, detection, and quantification limits of 2,45, 0,62, 1,02 mol L-1, respectively. And the recovery values of 103 and 108 % indicates the possibility of using this method in the forensic science
15

Desenvolvimento de um sistema eletroquímico de análise por injeção em fluxo para detecção de cocaína / Development of an Electrochemical Flow Injection Analysis system for Detection of Cocaine

Oliveira, Laura Siqueira de 17 January 2012 (has links)
O aumento nos índices de criminalidade, na maioria das vezes decorrente de atividades ligadas ao tráfico de drogas, afeta drasticamente a qualidade de vida do ser humano. A análise instrumental de entorpecentes é realizada comumente por métodos cromatográficos, oferecendo limites de detecção (LDs) em torno de 1 ng mL-1. As técnicas analíticas como voltametria, amperometria, potenciometria, dentre outras, assemelham-se às técnicas convencionais de análise, pois além de se mostrarem sensíveis para a análise de traços de substâncias orgânicas e inorgânicas, oferecem vantagens operacionais como a compreensão de mecanismos pato-fisiológicos de várias drogas, dentre elas a cocaína e seus metabólitos. Os eletrodos quimicamente modificados (EQMs) com bases de Schiff (grupos funcionais que contém uma ligação dupla carbono-nitrogênio com o átomo de nitrogênio conectado a um grupo arila ou alquila) desenvolvidos para a determinação de cocaína em amostras de interesse forense podem ser empregados em situação de análise por injeção em fluxo (FIA). Cuja metodologia consiste na inserção de uma alíquota de amostra em um fluido carregador que a transporta do ponto de injeção até a unidade de detecção. Atualmente a análise de cocaína está limitada à dosagem posterior de amostras apreendidas, uma vez que não há nenhum dispositivo portátil para a detecção da mesma em local de crime. Assim, este projeto visa desenvolver uma metodologia voltamétrica, por meio de eletrodos quimicamente modificados com bases de Schiff, e da aplicação dos mesmos em FIA para a detecção de cocaína em amostras de interesse forense. / The increase in crime occurrences, mostly due to activities linked to drug trafficking, dramatically affects the quality of human life. The instrumental analysis of drugs is commonly performed by chromatographic methods, offering limits of detection (LD) around 1 ng mL-1. Analytical techniques such as voltammetry, amperometry, potentiometry, among others, are similar to conventional analysis techniques, as well as prove sensitive for trace analysis of organic and inorganic substances, provide operational advantages as the understanding of pathophysiological mechanisms of several drugs, among them cocaine and its metabolites. The chemically modified electrodes (CMEs) with Schiff bases (functional groups containing a carbon-nitrogen double bond with the nitrogen atom attached to an alkyl or aryl group) developed for the determination of cocaine in samples of forensic interest can be used in situation of flow injection analysis (FIA). The methodology consists of inserting a sample rate of a carrier fluid that carries the point of injection to the detection unit. The analysis is limited to the dosage cocaine samples seized previously, since there is no portable device for detection in the same scene. Thus, this project aims to develop a voltammetric methodology, by means of chemically modified electrodes with Schiff bases, and applying them in the FIA for the detection of cocaine in samples of forensic interest.
16

Entre laudos, compostos químicos e máquinas : saberes e práticas a partir do Setor Técnico-Científico da Superintendência Regional do Departamento de Polícia Federal de Rio Grande do Sul

Besen, Lucas Riboli January 2014 (has links)
Esta dissertação tem como temática a relação entre a Antropologia do Direito e os Estudos Sociais da Ciência e da Tecnologia no que tange a produção de laudos periciais por peritos criminais federais. Tendo o Grupo de Perícias de Laboratório do Setor Técnico-Científico da Superintendência Regional do Departamento de Polícia Federal de Porto Alegre como local privilegiado de observação, busca-se problematizar as relações entre ciência e direito assim como compreender, através do acompanhamento dos peritos criminais federais na sua atividade cotidiana, como atores e organizações mobilizam, justapõem e mantêm unidos os elementos para constituir, ao fim, um laudo pericial. Nesse sentido, parte-se da perspectiva de que as esferas do direito e da ciência não estão separadas, mas são coproduzidas. Logo, procura-se potencializar os laudos periciais através da descrição da rede que envolve a sua produção. Parte-se da hipótese de que os laudos não são apenas um processo de purificação, mas a complexificação de uma rede que, ao final, resulta em um ator pontualizado, sendo que este performatiza um ordenamento da realidade condizente com uma ontologia política específica. Acredita-se que, através dessa pesquisa, poder-se-á complexificar as discussões já alçadas pela Antropologia Brasileira sobre a produção de justiça e de ciência, assim como alimentar o debate político sobre os limites e as potencialidades dos usos de provas científicas nos tribunais brasileiros. / This dissertation is about the relation between the Anthropology of Law and Rights studies and the Social Studies of Science and Technology regarding the production of forensic reports by federal forensic investigators. Having the Forensic Laboratory of the Techno-scientific Bureau of the Regional Superintendence of the Federal Police Department (SETEC/SR/DPF) at Porto Alegre city as a privileged observation site, I seek to discuss the relationship between the science and the law as well as to complexify, while observing the everyday tasks of the forensic investigators, how actors and organizations mobilize, juxtapose and keep together the elements that will constitute, after all, a forensic report. That being said, it is assumed from the start that law and science are not separated instances, but are coproduced. Therefore, I seek to potentiate the forensic reports through the description of the network that enables their production. I start with the hypothesis that the reports are not only a process of purification, but the complexification of a network that, by the end of the process, results in a punctualised actor that performs an ordering of reality aligned with a specific ontological politic. It is believed that, through this research, it will be possible to complexify the discussions raised by Brazilian Anthropology about the production of justice and science and to nurture the political debate about the limitations and potentialities of the usage of scientific evidence in Brazilian courts.
17

Entre laudos, compostos químicos e máquinas : saberes e práticas a partir do Setor Técnico-Científico da Superintendência Regional do Departamento de Polícia Federal de Rio Grande do Sul

Besen, Lucas Riboli January 2014 (has links)
Esta dissertação tem como temática a relação entre a Antropologia do Direito e os Estudos Sociais da Ciência e da Tecnologia no que tange a produção de laudos periciais por peritos criminais federais. Tendo o Grupo de Perícias de Laboratório do Setor Técnico-Científico da Superintendência Regional do Departamento de Polícia Federal de Porto Alegre como local privilegiado de observação, busca-se problematizar as relações entre ciência e direito assim como compreender, através do acompanhamento dos peritos criminais federais na sua atividade cotidiana, como atores e organizações mobilizam, justapõem e mantêm unidos os elementos para constituir, ao fim, um laudo pericial. Nesse sentido, parte-se da perspectiva de que as esferas do direito e da ciência não estão separadas, mas são coproduzidas. Logo, procura-se potencializar os laudos periciais através da descrição da rede que envolve a sua produção. Parte-se da hipótese de que os laudos não são apenas um processo de purificação, mas a complexificação de uma rede que, ao final, resulta em um ator pontualizado, sendo que este performatiza um ordenamento da realidade condizente com uma ontologia política específica. Acredita-se que, através dessa pesquisa, poder-se-á complexificar as discussões já alçadas pela Antropologia Brasileira sobre a produção de justiça e de ciência, assim como alimentar o debate político sobre os limites e as potencialidades dos usos de provas científicas nos tribunais brasileiros. / This dissertation is about the relation between the Anthropology of Law and Rights studies and the Social Studies of Science and Technology regarding the production of forensic reports by federal forensic investigators. Having the Forensic Laboratory of the Techno-scientific Bureau of the Regional Superintendence of the Federal Police Department (SETEC/SR/DPF) at Porto Alegre city as a privileged observation site, I seek to discuss the relationship between the science and the law as well as to complexify, while observing the everyday tasks of the forensic investigators, how actors and organizations mobilize, juxtapose and keep together the elements that will constitute, after all, a forensic report. That being said, it is assumed from the start that law and science are not separated instances, but are coproduced. Therefore, I seek to potentiate the forensic reports through the description of the network that enables their production. I start with the hypothesis that the reports are not only a process of purification, but the complexification of a network that, by the end of the process, results in a punctualised actor that performs an ordering of reality aligned with a specific ontological politic. It is believed that, through this research, it will be possible to complexify the discussions raised by Brazilian Anthropology about the production of justice and science and to nurture the political debate about the limitations and potentialities of the usage of scientific evidence in Brazilian courts.
18

Entre laudos, compostos químicos e máquinas : saberes e práticas a partir do Setor Técnico-Científico da Superintendência Regional do Departamento de Polícia Federal de Rio Grande do Sul

Besen, Lucas Riboli January 2014 (has links)
Esta dissertação tem como temática a relação entre a Antropologia do Direito e os Estudos Sociais da Ciência e da Tecnologia no que tange a produção de laudos periciais por peritos criminais federais. Tendo o Grupo de Perícias de Laboratório do Setor Técnico-Científico da Superintendência Regional do Departamento de Polícia Federal de Porto Alegre como local privilegiado de observação, busca-se problematizar as relações entre ciência e direito assim como compreender, através do acompanhamento dos peritos criminais federais na sua atividade cotidiana, como atores e organizações mobilizam, justapõem e mantêm unidos os elementos para constituir, ao fim, um laudo pericial. Nesse sentido, parte-se da perspectiva de que as esferas do direito e da ciência não estão separadas, mas são coproduzidas. Logo, procura-se potencializar os laudos periciais através da descrição da rede que envolve a sua produção. Parte-se da hipótese de que os laudos não são apenas um processo de purificação, mas a complexificação de uma rede que, ao final, resulta em um ator pontualizado, sendo que este performatiza um ordenamento da realidade condizente com uma ontologia política específica. Acredita-se que, através dessa pesquisa, poder-se-á complexificar as discussões já alçadas pela Antropologia Brasileira sobre a produção de justiça e de ciência, assim como alimentar o debate político sobre os limites e as potencialidades dos usos de provas científicas nos tribunais brasileiros. / This dissertation is about the relation between the Anthropology of Law and Rights studies and the Social Studies of Science and Technology regarding the production of forensic reports by federal forensic investigators. Having the Forensic Laboratory of the Techno-scientific Bureau of the Regional Superintendence of the Federal Police Department (SETEC/SR/DPF) at Porto Alegre city as a privileged observation site, I seek to discuss the relationship between the science and the law as well as to complexify, while observing the everyday tasks of the forensic investigators, how actors and organizations mobilize, juxtapose and keep together the elements that will constitute, after all, a forensic report. That being said, it is assumed from the start that law and science are not separated instances, but are coproduced. Therefore, I seek to potentiate the forensic reports through the description of the network that enables their production. I start with the hypothesis that the reports are not only a process of purification, but the complexification of a network that, by the end of the process, results in a punctualised actor that performs an ordering of reality aligned with a specific ontological politic. It is believed that, through this research, it will be possible to complexify the discussions raised by Brazilian Anthropology about the production of justice and science and to nurture the political debate about the limitations and potentialities of the usage of scientific evidence in Brazilian courts.
19

Desenvolvimento de método químico analítico forense para análise de merla por Análise Térmica e Cromatografia Gasosa de Alta Resolução / Development of forensic analytical chemistry method for examination of merla by Thermal Analysis and High Resolution Gas chromatography

MEDEIROS, Rodrigo Irani 18 March 2011 (has links)
Made available in DSpace on 2014-07-29T15:11:10Z (GMT). No. of bitstreams: 1 Tese Rodrigo I Medeiros.pdf: 2094204 bytes, checksum: 5d1ccae92a1ff1a8355428a531e6a4b9 (MD5) Previous issue date: 2011-03-18 / An analytical chemical method for the forensic analysis of an illicit drug merla, whose the main constituent is the cocaine was development. Thermogravimetric analysis admitted to understand the thermal behavior of samples and quantifying the stages of mass loss, which together with the quantification endothermic event in DSC, the results were essential for the generation of analytical answers used to construct the data matrix of the statistical analysis. An efficient process for the precipitation of inorganic substances was established, which simultaneously allowed the extraction of two liquid fractions, organic and aqueous, being determinate a partition coefficient of 96,22 % for cocaine, using ethyl acetate as solvent, which showed lower elution time (0.58 min.) among the solvents evaluated. A method by Fast GC for cocaine analysis was developed, reducing the analysis time of 14.5 to 4.5 min was developed, which allowed analyze merla sample and the normalization of the chromatographic peaks of cocaine, demonstrated the great variation of its concentration in merla. Noticed of the potential of the method involving the thermo-analytical and chromatographys techniques to generate experimental results obtained statistically enabled a classification and grouping of samples by Euclidean Distance by the Hierarchical Cluster Analysis (HCA), estimated whether seized samples with different users were manipulated in the same laboratory and if determined city has separate laboratories for illegal preparatiom of drug narcotic. / Neste estudo realizou-se o desenvolvimento de um método químico analítico forense para a análise de uma droga ilícita a base de cocaína, a merla. As análises termogravimétricas permitiram conhecer o comportamento térmico das amostras e quantificar as etapas de perdas de massa, que juntamente com a quantificação de evento endotérmico em DSC, foram essenciais para a geração de resultados analíticos utilizados na construção da matriz de dados do tratamento estatístico. Foi estabelecido um processo eficiente para a precipitação das substâncias inorgânicas, que simultaneamente permitiu a extração de duas frações líquidas, orgânica e aquosa, sendo determinado um coeficiente de partição de 96,22 % para a cocaína, tendo como solvente acetato de etila, o qual apresentou menor tempo de eluição (0,58 min.) dentre os solventes avaliados. Foi desenvolvido um método Fast GC para análise de cocaína, diminuindo o tempo de análise de 14,5 min para cerca de 4,5 min, o qual permitiu analisar as amostras de merla e, pela normalização dos picos cromatográficos da cocaína, perceber a grande variação de sua concentração na merla. Observou-se o potencial do método envolvendo as técnicas termoanalíticas e cromatográficas para geração de resultados experimentais que tratados estatisticamente possibilitaram a classificação e o agrupamento das amostras pela distância euclidiana obtida por Análise Hierárquica de Agrupamentos (HCA), avaliando se amostras apreendidas com diferentes usuários foram manipuladas em um mesmo laboratório e se determinada cidade possui laboratórios distintos de preparo ilegal de tóxico-entorpecente.
20

Desenvolvimento de sensores voltamétricos e piezelétricos modificados quimicamente com cucurbiturilas para análises de cocaína em amostras de interesse forense / Development of voltammetric and piezoelectric sensors chemically modified with cucurbiturils for analysis of cocaine in samples of forensic interest.

Matheus Manoel Teles de Menezes 14 November 2014 (has links)
Considerando a relevância dos trabalhos onde se utiliza eletrodos quimicamente modificados e o pequeno número de estudos envolvendo cocaína e seus interferentes (cafeína, teobromina e lidocaína), por técnicas eletroquímicas ou piezelétricas, este estudo tem como objetivo o desenvolvimento de eletrodos de ouro e platina quimicamente modificados com compostos da classe das cucurbiturilas (CB[5], CB[6] e CB[7]) para a detecção de cocaína. A técnica de microbalança de cristal de quartzo foi empregada a fim de se estudar cocaína padrão e seus interferentes, em fase gasosa. Os eletrodos de ouro foram quimicamente modificados com cucurbiturilas e o modificador CB[6] apresentou os melhores resultados. Medidas por voltametria cíclica foram realizadas utilizando-se um potenciostato Autolab III acoplado a um computador, com eletrodo de ouro e platina atuando como eletrodo de trabalho, Ag/AgCl como eletrodo de referência e eletrodo espiral de platina como eletrodo auxiliar, com velocidade de varredura de 0,1 V.s-1 (100 mV.s-1). Os parâmetros voltamétricos foram otimizados para tornar as análises mais rápidas e sensíveis sem perda de qualidade ou intensidade do sinal voltamétrico. O eletrodo de platina quimicamente modificado com filme de cucurbit[6]urila apresentou aumento da corrente de pico catódica quando estudado frente à cocaína, teobromina e lidocaína. Análises com eletrodo de platina sem modificador químico apresentaram limite de detecção de 4,14.10-6 mol.L-1 e limite de quantificação de 1,38.10-5 mol.L-1 , para a cocaína, e na presença do modificador químico CB[6] apresentou limite de detecção de 1,36.10-6 mol.L-1 e limite de quantificação de 4,54.10-6 mol.L-1 . Eletrodos de ouro com ou sem a presença de modificadores químicos não apresentaram sinal para nenhum analito. / Considering the importance of chemically modified electrodes and the small amount of the cocaine study and their interfering (caffeine, theobromine and lidocaine) using electrochemical and piezoelectric techniques, this study aims to investigate the development of the gold and platinum electrodes chemically modified by cucurbiturils (CB[5], CB[6] and, CB[7]) in order to detect cocaine. The Quartz Crystal Microbalance technique was employed in order to study in gas phase the standard samples of cocaine and their interfering. Gold electrode was chemically modified with cucurbiturils films and the CB[6] modifier showed the best results. The cyclic voltammetric measurements were performed using a Autolab III potentiostat coupled to a computer, being gold and platinum as the working electrode, Ag/AgCl as the reference electrode and platinum wire as counter electrode, using a scan rate of 0,1 V.s-1 (100 mV.s-1). The voltammetric parameters were optimized in order to make the analysis faster and more sensitive without loss of intensity and quality of the voltammetric signal. The platinum electrode modified by cucurbit[6]uril film showed an increase of cathodic current peak when electrode was exposed to cocaine, theobromine and lidocaine. Analysis employed platinum working electrode without chemical modifier showed a detection limit of 4.14 . 10-6 mol.L-1 and quantification limit of 1.38 . 10-5 mol.L-1 for cocaine and with chemical modifier CB[6] showed a detection limit of 1.36 . 10-6 mol.L-1 and quantification limit of 4.54 . 10-6 mol.L-1 . Gold electrodes with or without chemical modifiers showed no response for any analyte.

Page generated in 0.0951 seconds